{"Manifests":[{"AffectedList":[],"AuthenticationDetails":{},"AuthenticationMethod":"","BundleISOLocation":"","BundleId":"2026.09.00.00","CompLocation":"","ComponentDownloadServer":"","DefaultComponentDownloadServer":"","DeniedList":[],"Manifest":[{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52008TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b460823f70-HPG4-1.1.x86_64.rpm","SHA1Sum":"cc7dfe4a1d255a10967f6872c307fc8451bece6d","SHA256Sum":"83cefbc197cc712352f311db7850d4a8c1aa60493ffaa05fba6bfc12163d3468","SHA512Sum":"675d4c570ee17ad1aac7cdb63b36f368bc41358327e14a4ad577dbf087c1427c0c2ceedd39950d95afef062f500a2ad1a952111921c57af6b51647b8618ae4f5"}],"ComponentSizeInKB":5152,"CompsigList":["firmware-hdd-b460823f70-HPG4-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/CP072162.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/M52008TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072162.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072162.scexe"],"Name":"firmware-hdd-b460823f70-HPG4-1.1.x86_64.rpm","SHA1Sum":"cc7dfe4a1d255a10967f6872c307fc8451bece6d","SHA256Sum":"83cefbc197cc712352f311db7850d4a8c1aa60493ffaa05fba6bfc12163d3468","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3730-3638-30475753584e"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK007680GWSXN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK007680GWSXN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f5f5e93d0ec4625934183860d","SupportedDevices":["562340a5-304b-3730-3638-30475753584e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A43_4.04_04_02_2026.fwpkg","SHA1Sum":"304da07141e981ad5c1a5bd1f07eebe926225291","SHA256Sum":"27e85046a8daf7a3850153afc40045e5fb31e3f01cace1e78a6fc3beaa119f2a","SHA512Sum":"d215cf7e07e3b9dd54fc1e3eb1b61e50edd6f1e373d90077c3195c5c71dd52c3e2a66ec84c1403b1c9c4a9f4685222b0456317aafa28e53b66e2b2883df70d3f"}],"ComponentSizeInKB":32819,"CompsigList":[],"FileList":["A43_4.04_04_02_2026.signed.flash","A43_4.04_04_02_2026.xml","payload.json"],"Name":"A43_4.04_04_02_2026.fwpkg","SHA1Sum":"304da07141e981ad5c1a5bd1f07eebe926225291","SHA256Sum":"27e85046a8daf7a3850153afc40045e5fb31e3f01cace1e78a6fc3beaa119f2a","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f733631a13284947aacf491e0a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A43","A43","A43"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"CP070903.zip","SHA1Sum":"5ca9a82fac8c080b82933a6b81aec789db31a342","SHA256Sum":"2801f534d4c00238958861bc0e0be21888de589b8426a0f708d8d73aef8e4529","SHA512Sum":"85852ed17c596b9c708f4ce2c5fdb22cdad0dace8aa1883439d21377cba9c12d80bf60d4cb4be4c2ab7285c330d1f836e070fb306158bf6a217dfb5140d63fed"}],"ComponentSizeInKB":22053,"CompsigList":["CP070903.compsig"],"FileList":["/CP070903_BUILD_3.data","/CP070903.vmexe64","/CP070903.vmfile","/CP070903_VMw.zip","/CP070903.xml","/payload.json","/CP070903_VMw.zip/index.xml","/CP070903_VMw.zip/vendor-index.xml","/CP070903_VMw.zip/metadata.zip","/CP070903_VMw.zip/vib20/CP070903/HPE_bootbank_CP070903_HPK4.3-8.0.0.20613240.vib","/CP070903_VMw.zip/metadata.zip/vendor-index.xml","/CP070903_VMw.zip/metadata.zip/vmware.xml","/CP070903_VMw.zip/metadata.zip/vibs/CP070903-560840138915920864.xml","/CP070903_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070903_HPK4.3-8.0.0.20613240.xml"],"Name":"CP070903.zip","SHA1Sum":"5ca9a82fac8c080b82933a6b81aec789db31a342","SHA256Sum":"2801f534d4c00238958861bc0e0be21888de589b8426a0f708d8d73aef8e4529","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4","VibList":[{"Name":"CP070903","Version":"HPK4.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_affe92f0e28d408f95167ca9fa","SupportedDevices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072380.zip","SHA1Sum":"391dec687b0bffeaf942382a82f99e49686e905e","SHA256Sum":"6107a93d67a09e67f311552b661f0c251a424cabafb0de211c0e98a2a13d621d","SHA512Sum":"0f1194e79b7e97a2f3669111225180cdceca6dd3dfc6ff80584fe26a97b4ddd0f1e38bbf7ef2ad711b66edacecd58d9f5c3d990e2c44747a42928ca11103408e"}],"ComponentSizeInKB":17164,"CompsigList":["CP072380.compsig"],"FileList":["/CP072380.xml","/CP072380_VMw.zip","/payload.json","/CP072380.vmexe64","/CP072380.vmfile","/CP072380_VMw.zip/index.xml","/CP072380_VMw.zip/vendor-index.xml","/CP072380_VMw.zip/metadata.zip","/CP072380_VMw.zip/vib20/CP072380/HPE_bootbank_CP072380_1.0.0-8.0.0.21495797.vib","/CP072380_VMw.zip/metadata.zip/vendor-index.xml","/CP072380_VMw.zip/metadata.zip/vmware.xml","/CP072380_VMw.zip/metadata.zip/vibs/CP072380--3244865110063769315.xml","/CP072380_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072380_1.0.0-8.0.0.21495797.xml"],"Name":"CP072380.zip","SHA1Sum":"391dec687b0bffeaf942382a82f99e49686e905e","SHA256Sum":"6107a93d67a09e67f311552b661f0c251a424cabafb0de211c0e98a2a13d621d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.4","VibList":[{"Name":"CP072380","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_686f4d0a3bd64f50b82020a09f","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U32","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","U37"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"WDC-ParisD-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"WDC_ParisD_WPDQAK90HPD2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5655","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"WDC_ParisD_WPDQAK90HPD2.fwpkg","SHA1Sum":"7cefaa5f644d39379688a5908ed808c27f7a3738","SHA256Sum":"94d6a775902eafead0aa31937766c19bdf7d41d4ff48ad7e3921414adbdd2e41","SHA512Sum":"6e33ca9e862a384bdb9dbf996262dd577446e32ba76c4a8ac6699e2f3cd099b3b5f8a72363d736d2c593291abb8ca3d65e06ab86555101174b192702e6c5a397"}],"ComponentSizeInKB":6933,"CompsigList":[],"FileList":["payload.json","WDC_ParisD_WPDQAK90HPD2.HPb","WDC_ParisD_WPDQAK90HPD2.xml"],"Name":"WDC_ParisD_WPDQAK90HPD2.fwpkg","SHA1Sum":"7cefaa5f644d39379688a5908ed808c27f7a3738","SHA256Sum":"94d6a775902eafead0aa31937766c19bdf7d41d4ff48ad7e3921414adbdd2e41","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5655"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB020000JXMVU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMVU","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_10ed23b787c44275811345156c","SupportedDevices":["4d2340a5-3042-3032-3030-304a584d5655"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","15.0","9.0","16.0","10.0","26.04","24.04"]},{"OS":"VMware","Version":["8.0","9.0","9.1"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-492a9952f6-HPG5-5.1.x86_64.rpm","SHA1Sum":"4d01ce997d738d0108847e21fb1f1cccd6fd4646","SHA256Sum":"5521433ec50d0907e4ea8432111d8d87dc90aace20d3c11ea288a913432fc5e7","SHA512Sum":"3591874ec60eac1e0fcd3610145b7118fd367ec42b6de6072694d0633f2b8960831268df370442afc068c87b3b443331ffd3f777e25e93f804d790bc4520c7fe"}],"ComponentSizeInKB":5861,"CompsigList":["firmware-hdd-492a9952f6-HPG5-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/CP068907.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/K401HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068907.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068907.scexe"],"Name":"firmware-hdd-492a9952f6-HPG5-5.1.x86_64.rpm","SHA1Sum":"4d01ce997d738d0108847e21fb1f1cccd6fd4646","SHA256Sum":"5521433ec50d0907e4ea8432111d8d87dc90aace20d3c11ea288a913432fc5e7","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5a63b21feb2248f7a2d9ef0791","SupportedDevices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVLACBA0HPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP073161.zip","SHA1Sum":"4ada96f00fd548983fe3d8bd4e9f21433284015a","SHA256Sum":"65c5bcacf630ef65fbfe8360b58d473c7fbe5eb5e79b7d167feeac38b20f77e4","SHA512Sum":"baf7f97c5f89867c13b0614af2fa3c949966452c853f9a024a8c579a28cc8bc9bbe6fd178ed14b1eb4aba2593779bccfcd83dcd775e316decb88ae4323343940"}],"ComponentSizeInKB":20196,"CompsigList":["CP073161.compsig"],"FileList":["/CP073161_BUILD_1.data","/CP073161.vmexe64","/CP073161.vmfile","/CP073161_VMw.zip","/CP073161.xml","/payload.json","/CP073161_VMw.zip/index.xml","/CP073161_VMw.zip/vendor-index.xml","/CP073161_VMw.zip/metadata.zip","/CP073161_VMw.zip/vib20/CP073161/HPE_bootbank_CP073161_HPD4.1-8.0.0.20613240.vib","/CP073161_VMw.zip/metadata.zip/vendor-index.xml","/CP073161_VMw.zip/metadata.zip/vmware.xml","/CP073161_VMw.zip/metadata.zip/vibs/CP073161-6000029838379535574.xml","/CP073161_VMw.zip/metadata.zip/bulletins/Smart-Component-CP073161_HPD4.1-8.0.0.20613240.xml"],"Name":"CP073161.zip","SHA1Sum":"4ada96f00fd548983fe3d8bd4e9f21433284015a","SHA256Sum":"65c5bcacf630ef65fbfe8360b58d473c7fbe5eb5e79b7d167feeac38b20f77e4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP073161","Version":"HPD4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWKGU Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5c1c301aa38f4400ab2c08cd6a","SupportedDevices":["4d2340a5-3042-3430-3030-304a574b4755"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a07a420ed1-HPD5-6.1.x86_64.rpm","SHA1Sum":"88b7cf0cd5752fc896dd18bc514db5659e8959ca","SHA256Sum":"85dafec3d8c68c68c90eab44b2418b2680c17ebbfabd353a0e027e863d1c21dd","SHA512Sum":"71d342c0dde42a3425a3e05eabf6ec463c59a08adaef1bbcdf91f5403f04687e757a53dbd402aaf6f442d68eb0f3d738334b63ff0998b5f53b2d8b9dc3ac5669"}],"ComponentSizeInKB":5186,"CompsigList":["firmware-hdd-a07a420ed1-HPD5-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/CP068913.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/GPM1645ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068913.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068913.scexe"],"Name":"firmware-hdd-a07a420ed1-HPD5-6.1.x86_64.rpm","SHA1Sum":"88b7cf0cd5752fc896dd18bc514db5659e8959ca","SHA256Sum":"85dafec3d8c68c68c90eab44b2418b2680c17ebbfabd353a0e027e863d1c21dd","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1da10066bcaf487dad617cdc66","SupportedDevices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068754.exe","SHA1Sum":"e69ff50e88568f5169b0c6cfa353b77d81d505bc","SHA256Sum":"bd82062a5d295162781206cd34819a6bf393bbfe0a3b1c3bb9b228f30007649b","SHA512Sum":"d60a102ef4aedb19092b0b760a0d68dba6abb0992a689448d846db7c2dd0ae00962d04af68d90e72b9fd667ae16b015b52a169cf26a8c01fcc47aafd3b7041ff"}],"ComponentSizeInKB":3559,"CompsigList":["cp068754.compsig"],"FileList":["cp068754.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TATCATSATAG1.rel"],"Name":"cp068754.exe","SHA1Sum":"e69ff50e88568f5169b0c6cfa353b77d81d505bc","SHA256Sum":"bd82062a5d295162781206cd34819a6bf393bbfe0a3b1c3bb9b228f30007649b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9dc1ac030cb645d69083765516","SupportedDevices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069544.exe","SHA1Sum":"67171d244ac3dbb24e73b7c1c796416ab86b7127","SHA256Sum":"6d0392353e562c2235e18836547ac15bf57fcdb0cf2e7e439f2adf76e2cc5684","SHA512Sum":"95aa410a97557cf7551f0bece33db39715fbdeaeac3e463ef53f89b17f29f7947427c6888b5f8ac588493979d9cf2f87e756b1e461f93e1832aa2db5bc0e4bc6"}],"ComponentSizeInKB":1054,"CompsigList":["cp069544.compsig"],"FileList":["cp069544.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069544.exe","SHA1Sum":"67171d244ac3dbb24e73b7c1c796416ab86b7127","SHA256Sum":"6d0392353e562c2235e18836547ac15bf57fcdb0cf2e7e439f2adf76e2cc5684","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.0.13.0"}],"InstallationDependency":{},"Name":"Intel i350 Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755374"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a556c13877764198a3876ee835","SupportedDevices":["a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd-5.1.0-2197.8.sles15.x86_64.rpm","SHA1Sum":"b34bbdba2224207c49ca242bf11eb28eae206aff","SHA256Sum":"252aded8ecc8e45e32550c85b389c55af8f2e719fb5187d897fd8f3c0892a51d","SHA512Sum":"2c05f16b5e471c7a3e2ff879039673664d246e7b23dbab8454bf421cff8c30d5198e03e75238a35f65f27b74f6a4b261e50556c4d5561fc2eae57e11b8cb72d4"}],"ComponentSizeInKB":11376,"CompsigList":["amsd-5.1.0-2197.8.sles15.x86_64.compsig"],"FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/1c","./usr/lib/.build-id/1c/553f42634c7caf14a39c3deba409e1ceaa2ae6","./usr/lib/.build-id/1c/553f42634c7caf14a39c3deba409e1ceaa2ae6.1","./usr/lib/.build-id/25","./usr/lib/.build-id/25/f6ebf16795cb2c9e0cfb498222d6b2c872e985","./usr/lib/.build-id/25/f6ebf16795cb2c9e0cfb498222d6b2c872e985.1","./usr/lib/.build-id/28","./usr/lib/.build-id/28/87bd7d2760429c1ced4e9fa2dfa9a010cd3d6b","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/cf989a36f5488be20627d26f8c18e0f46ebfcd","./usr/lib/.build-id/3c/cf989a36f5488be20627d26f8c18e0f46ebfcd.1","./usr/lib/.build-id/8b","./usr/lib/.build-id/8b/5d9797a0aabcc819255f60768c2970279f816c","./usr/lib/.build-id/8d","./usr/lib/.build-id/8d/a7a5010d5ae652c513c455e05ccbc659d14396","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/b1726dfd5ddd795d0f0806e1d28e226966ac31","./usr/lib/.build-id/c8/b1726dfd5ddd795d0f0806e1d28e226966ac31.1","./usr/lib/.build-id/d0","./usr/lib/.build-id/d0/d299c5f060d61d44c3725c475a299a5bf0b4b9","./usr/lib/.build-id/d0/d299c5f060d61d44c3725c475a299a5bf0b4b9.1","./usr/lib/.build-id/d3","./usr/lib/.build-id/d3/f4f4e79fb0baee75426a81e5f8334842aa4aef","./usr/lib/.build-id/d3/f4f4e79fb0baee75426a81e5f8334842aa4aef.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"Name":"amsd-5.1.0-2197.8.sles15.x86_64.rpm","SHA1Sum":"b34bbdba2224207c49ca242bf11eb28eae206aff","SHA256Sum":"252aded8ecc8e45e32550c85b389c55af8f2e719fb5187d897fd8f3c0892a51d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"5.1.0"}],"InstallationDependency":{},"Name":"Agentless Management Service (iLO5 and above) for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0da5cd24cd724962aaaa9fd21e","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-103c-330615903307","a6b1a447-382a-5a4f-103c-330715903307","a6b1a447-382a-5a4f-103c-3307159004bd","a6b1a447-382a-5a4f-103c-3306159004bd"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U43","U41","U33","U44","A47","A48","U40","U47","U45","U24","U37","A46","U47","U38","U38","A45","U50","U46","I43","I45","I44","I42","A42","U54","U54","U54","U61","U60","U58","U58","U63","U63","A55","A55","A56","A56","U59","U58","U57","U65","U65","U62","A58","U69","U69","H11","I46","U68","U68","U68","U71","U66","U71","U72","U68","U72","U70","A59","U73","A66","A66","U74","U77","U71","U77","A72","U83"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL8CBA0HPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"CP073256.zip","SHA1Sum":"1ab42ba731a7c8c1b6022bdef15fbccc15428af3","SHA256Sum":"be39ff3cbc9ed5a7c472873f87d35828e5604c1fdcd5bd238843ed3d7d2c69c5","SHA512Sum":"b30ea5e852b224640f3f107264f33a00d91f45a9707f11e1041b010e60d55a81cf239682ce065cf87e9cf0f14c75c1e2bbdad1b7b0486435fd6588da29cd902f"}],"ComponentSizeInKB":19963,"CompsigList":["CP073256.compsig"],"FileList":["/CP073256_BUILD_1.data","/CP073256.vmexe64","/CP073256.vmfile","/CP073256_VMw.zip","/CP073256.xml","/payload.json","/CP073256_VMw.zip/index.xml","/CP073256_VMw.zip/vendor-index.xml","/CP073256_VMw.zip/metadata.zip","/CP073256_VMw.zip/vib20/CP073256/HPE_bootbank_CP073256_HPD3.1-8.0.0.20613240.vib","/CP073256_VMw.zip/metadata.zip/vendor-index.xml","/CP073256_VMw.zip/metadata.zip/vmware.xml","/CP073256_VMw.zip/metadata.zip/vibs/CP073256--2558498280305350060.xml","/CP073256_VMw.zip/metadata.zip/bulletins/Smart-Component-CP073256_HPD3.1-8.0.0.20613240.xml"],"Name":"CP073256.zip","SHA1Sum":"1ab42ba731a7c8c1b6022bdef15fbccc15428af3","SHA256Sum":"be39ff3cbc9ed5a7c472873f87d35828e5604c1fdcd5bd238843ed3d7d2c69c5","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP073256","Version":"HPD3.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWRTD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a1e7552292414740a7310bc6fc","SupportedDevices":["4d2340a5-3042-3830-3030-304a57525444"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX631102 10/25GbE 2p SFP28 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_49_1014-MCX631102AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30012","Version":"26.49.1014"}]},"Files":[{"Checksum":[{"Filename":"26_49_1014-MCX631102AS-ADA_Ax.pldm.fwpkg","SHA1Sum":"b8ca210fabb1f189250f1952f8b4c2d0b3a3fded","SHA256Sum":"2422a8b32f8fa3bb353ca638e18d0dbd8e1ff9f69b9e24646729631f4314b068","SHA512Sum":"a57ed7ec2c609ab0601f6f78d40bb7ec068b279bfcca7b281282b8e05669ba40d6a7218ea990bead7712c7cf7aa3f6dcbf4b1b8ab7ef0b3dccafadb80dc35488"}],"ComponentSizeInKB":7183,"CompsigList":[],"FileList":["26_49_1014-MCX631102AS-ADA_Ax.pldm.signed","26_49_1014-MCX631102AS-ADA_Ax.pldm.xml","payload.json"],"Name":"26_49_1014-MCX631102AS-ADA_Ax.pldm.fwpkg","SHA1Sum":"b8ca210fabb1f189250f1952f8b4c2d0b3a3fded","SHA256Sum":"2422a8b32f8fa3bb353ca638e18d0dbd8e1ff9f69b9e24646729631f4314b068","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f15b30012"],"TypeOfChange":"1","Version":"26.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) - Mellanox MCX631102AS-ADAT Ethernet 10/25Gb 2-port SFP28 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX631102AS-ADAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9c4916603dc04cdcb314d13738","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f15b30012"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U62","U63","U57","A55","A55","A56","A56","U59","U58","U69","U69","U72","U70","U63","U65","U65","U68","U68","U68","A59","A66","A66","U72","U77","A72"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071623.zip","SHA1Sum":"6455dbe1c30c3f1936896f141f75628eab28b22a","SHA256Sum":"0348fafb40798b5937c629d8f91e73d54a1a69931d7d3eddf466c7b8a5c2966c","SHA512Sum":"bc06ad0096aa0925bf22b8726d876b9abdf4df58c78a2adff28ed2b221a954afa0e32da94d71bd6996643d593ae4bee52a86bc6749a52dc71d798593eaec752e"}],"ComponentSizeInKB":17270,"CompsigList":["cp071623.compsig"],"FileList":["/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip","/BCM_bootbank_storcli_007.3811.0300-1OEM.900.0.24755229.vib","/cp071623.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/index.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/vendor-index.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/vib20/storcli/BCM_bootbank_storcli_007.3811.0300-1OEM.900.0.24755229.vib","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip/vibs/storcli-9011262720796999315.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip/bulletins/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.xml"],"Name":"cp071623.zip","SHA1Sum":"6455dbe1c30c3f1936896f141f75628eab28b22a","SHA256Sum":"0348fafb40798b5937c629d8f91e73d54a1a69931d7d3eddf466c7b8a5c2966c","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2026.09.01","VibList":[{"Name":"storcli","Version":"007.3811.0300-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for VMware9.0 (For Gen10P and Gen11  Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"BCM-storcli:007.3811.0300-1OEM.900.0.24755229","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3811.0300-1OEM.900.0.24755229","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6a535ba577ca4f03a7052eff1f","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U54","U54","U54","U58","U63","U58","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","A72","U71","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068643.exe","SHA1Sum":"27cdd8ba2913c36c149dbd12fe2c97971b68564b","SHA256Sum":"c3b24244cd3265f4a995f24e5543a009d6d7f1b5336b5d7e4f572e9f32e97571","SHA512Sum":"e714053d96d16ced8c7637498dc550d104c630fed8b54882624b94e4025e2ef0d242a97906b0beb34b66e8f6ff918e06c919174a4ffbaf03af4c42b3c944130c"}],"ComponentSizeInKB":4832,"CompsigList":["cp068643.compsig"],"FileList":["cp068643.xml","cpqsetup.exe","HPG1PM893.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068643.exe","SHA1Sum":"27cdd8ba2913c36c149dbd12fe2c97971b68564b","SHA256Sum":"c3b24244cd3265f4a995f24e5543a009d6d7f1b5336b5d7e4f572e9f32e97571","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a8c1c0fb65e04e15a97628a36f","SupportedDevices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-SummitAN-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_SummitAN_SUMMITSUANG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3231-3030-304759455350","Version":"HPG3"},{"DeviceName":"Seagate-SummitAN-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_SummitAN_SUMMITSUANG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3631-3030-304759455646","Version":"HPG3"},{"DeviceName":"Seagate-SummitAN-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_SummitAN_SUMMITSUANG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3032-3030-304759455648","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"Seagate_SummitAN_SUMMITSUANG3.fwpkg","SHA1Sum":"0230c9da70b5ff84e8a16c69942fe770a21397d9","SHA256Sum":"f067a2e5d043c645c1a5f5c75e3253223a0b134f73700b8793b9cd349ea05a77","SHA512Sum":"81f948f4c806fce62bf05c03a8b4497dd3e177bbe00e01ceb599059177e1b7427c0baebd0e74f47a7b7e1f3ee55f3cdff3f01c57e376b1407c0c0cf9e43245b6"}],"ComponentSizeInKB":3681,"CompsigList":[],"FileList":["payload.json","Seagate_SummitAN_SUMMITSUANG3.HPb","Seagate_SummitAN_SUMMITSUANG3.xml"],"Name":"Seagate_SummitAN_SUMMITSUANG3.fwpkg","SHA1Sum":"0230c9da70b5ff84e8a16c69942fe770a21397d9","SHA256Sum":"f067a2e5d043c645c1a5f5c75e3253223a0b134f73700b8793b9cd349ea05a77","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-424d-3231-3030-304759455350","002340a5-424d-3631-3030-304759455646","002340a5-424d-3032-3030-304759455648"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MB12000GYESP, MB16000GYEVF and MB20000GYEVH","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB12000GYESP","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB16000GYEVF","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB20000GYEVH","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5f513eeaa56341f499c99db39a","SupportedDevices":["002340a5-424d-3231-3030-304759455350","002340a5-424d-3631-3030-304759455646","002340a5-424d-3032-3030-304759455648"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c993b31232-HPG6-7.1.x86_64.rpm","SHA1Sum":"f042b7b3fd37a879b025b1e286e020ef0e676742","SHA256Sum":"e7fdcc658931d881dbbdd51c23b3d06ec5797d0326377555cc3e5d7416084c99","SHA512Sum":"75fc4e390b30b060943f7055102bbdc4f9b3dc40b7f18a02e9bbd5e036b583ffbf7ceb16983a66f601206eac7414267a842c1e192001376d33f1c683388df839"}],"ComponentSizeInKB":5017,"CompsigList":["firmware-hdd-c993b31232-HPG6-7.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/CP068856.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/TAMG06ACHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068856.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068856.scexe"],"Name":"firmware-hdd-c993b31232-HPG6-7.1.x86_64.rpm","SHA1Sum":"f042b7b3fd37a879b025b1e286e020ef0e676742","SHA256Sum":"e7fdcc658931d881dbbdd51c23b3d06ec5797d0326377555cc3e5d7416084c99","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b55a0487e34c45578e26e301d0","SupportedDevices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072362.zip","SHA1Sum":"58a578554b5ac2001a4ccbd6380efadfce37cf49","SHA256Sum":"b3544708463c59214b4e00246daa417a97020722d70e9f18c69bf17bf5f8614b","SHA512Sum":"58da7645fbe799b2156a4219561ece1aa01137db445f1c847637d5c44e75456cd47ac6a1133a81b06e5e20fdadc78487e2198fdacaa8cd7371116241fb2e7853"}],"ComponentSizeInKB":22795,"CompsigList":["CP072362.compsig"],"FileList":["/CP072362.xml","/CP072362_VMw.zip","/payload.json","/CP072362.vmexe64","/CP072362.vmfile","/CP072362_VMw.zip/index.xml","/CP072362_VMw.zip/vendor-index.xml","/CP072362_VMw.zip/metadata.zip","/CP072362_VMw.zip/vib20/CP072362/HPE_bootbank_CP072362_1.0.2-1OEM.900.0.24755229.vib","/CP072362_VMw.zip/metadata.zip/vendor-index.xml","/CP072362_VMw.zip/metadata.zip/vmware.xml","/CP072362_VMw.zip/metadata.zip/vibs/CP072362-3589829479576141667.xml","/CP072362_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072362_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP072362.zip","SHA1Sum":"58a578554b5ac2001a4ccbd6380efadfce37cf49","SHA256Sum":"b3544708463c59214b4e00246daa417a97020722d70e9f18c69bf17bf5f8614b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP072362","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for HPE Mellanox Ethernet only adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d98fa56154f5469eb77d87f26f","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","P89","U32","P89","U36","U22","U41","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U39","U19","U56","U61","U45","U25","U37","HPE ProLiant SL4500 Chassis","U39","HPE Apollo 6500 Gen10 System"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE e920 10GbE 2p Network Mezzanine Kit","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101f1590012c","Version":"26.43.1014"}]},"Files":[{"Checksum":[{"Filename":"26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.fwpkg","SHA1Sum":"d8581abec6fc550febdab1bf76155b31fc682b72","SHA256Sum":"8414e0000cab2de2793f4eb21f363d1466c5967fbd40b95a1695bd7a4b0eda7f","SHA512Sum":"3d244e6ebd06a83a7e1f8ff6440a2ad71b70aa54359dc720c7ad14c61195a932123e996d352f07c259dd164b2557ca2da074db63dd3447613c1249e59ed1fdee"}],"ComponentSizeInKB":6550,"CompsigList":[],"FileList":["26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.signed","26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.xml","payload.json"],"Name":"26_43_1014-FWEdgelinee920ConnectX-6Lx10Gb2-portNetworkMezzanine_Ax.pldm.fwpkg","SHA1Sum":"d8581abec6fc550febdab1bf76155b31fc682b72","SHA256Sum":"8414e0000cab2de2793f4eb21f363d1466c5967fbd40b95a1695bd7a4b0eda7f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f1590012c"],"TypeOfChange":"1","Version":"26.43.1014"}],"InstallationDependency":{},"Name":"Mellanox Firmware Package (FWPKG) for  HPE Edgeline e920 ConnectX-6Lx 10Gb 2-port Mezzanine Adapter :  HPE part number P40899-B21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_E920CX6LX_MEZZ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3ddc1bf7dbbb4a3f823e4a876f","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f1590012c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["H10","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG6"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG6"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG6"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"cp070086.exe","SHA1Sum":"8cbbdef6c0e95da728495a8815790e260bc69ebf","SHA256Sum":"07de0123992a92d0acb1b889bcbae6b5879829041d5681a122b6dd55b73aba1a","SHA512Sum":"1ba063ce3f13c9fa46aba28216802114f846d229f6340a68deec00c39a6b317841fd667d138caea9fdce9e4604d9fb8bcb48ef864e76f65ebb1bf718bb337f3e"}],"ComponentSizeInKB":4054,"CompsigList":["cp070086.compsig"],"FileList":["cp070086.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG09acHPG6.REL"],"Name":"cp070086.exe","SHA1Sum":"8cbbdef6c0e95da728495a8815790e260bc69ebf","SHA256Sum":"07de0123992a92d0acb1b889bcbae6b5879829041d5681a122b6dd55b73aba1a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_481db77156ae459e8d2d236d7b","SupportedDevices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072100.zip","SHA1Sum":"1e87cffce10f0fd6487890d0d401a27136218ce2","SHA256Sum":"01b79e46d6fdd1b7672a049905cbbf6ad80a0c7c2def7fa1c983ecf5777816c5","SHA512Sum":"bd221b0311d5527844a4494a75d27f4c301ac8880d19f855d23582db3f61f3c14765c1cd9b5aea16ee2c337c3df06db126b757582317801c366bee8ba5ba42e1"}],"ComponentSizeInKB":17089,"CompsigList":["cp072100.compsig"],"FileList":["/cp072100.xml","/MIS_bootbank_ssacli2_6.65.9.0-1OEM.800.1.0.20613240.vib","/ssacli2-component_6.65.9.0-0.zip","/ssacli2-component_6.65.9.0-0.zip/index.xml","/ssacli2-component_6.65.9.0-0.zip/vendor-index.xml","/ssacli2-component_6.65.9.0-0.zip/metadata.zip","/ssacli2-component_6.65.9.0-0.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.65.9.0-1OEM.800.1.0.20613240.vib","/ssacli2-component_6.65.9.0-0.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.65.9.0-0.zip/metadata.zip/vmware.xml","/ssacli2-component_6.65.9.0-0.zip/metadata.zip/vibs/ssacli2-5213612587468599283.xml","/ssacli2-component_6.65.9.0-0.zip/metadata.zip/bulletins/ssacli2-component_6.65.9.0-0.xml"],"Name":"cp072100.zip","SHA1Sum":"1e87cffce10f0fd6487890d0d401a27136218ce2","SHA256Sum":"01b79e46d6fdd1b7672a049905cbbf6ad80a0c7c2def7fa1c983ecf5777816c5","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"ssacli2","Version":"6.65.9.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 8.0 for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"ssacli2-component:6.65.9.0-0","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.65.9.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bbbcfe855d6a4fdaaa14c83925","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U43","U41","U33","U44","U40","U45","U37","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","U51","A47","A48","U50","U47","A46","U47","A48","U48","U47","U47","U50","U46","I44","U38","U38","U38","U40","U40","U39","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U46","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","P92","P95","P99","U23","O42","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I39","I40","I37","U57","U62","U65","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071991.exe","SHA1Sum":"5012f93a40c4cbad2e5fee16bf1b861297643546","SHA256Sum":"3ee5db72af1e8295aa353cd17cec8ef2853688587f15509edda4a77026f28a82","SHA512Sum":"bd7896e653109ffc3dc6117ca83622c9d7912aa8b058aaf61caa7060a458225d6b646019716e34b6b453de71457347e17ce37086066302bda579a5a043c1af21"}],"ComponentSizeInKB":678,"CompsigList":["cp071991.compsig"],"FileList":["cp071991.xml","cpqsetup.exe","installer.dll","non-pnp/","non-pnp/amdpshed.cat","non-pnp/amdpshed.inf","non-pnp/amdpshed.sys"],"Name":"cp071991.exe","SHA1Sum":"5012f93a40c4cbad2e5fee16bf1b861297643546","SHA256Sum":"3ee5db72af1e8295aa353cd17cec8ef2853688587f15509edda4a77026f28a82","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"TypeOfChange":"1","Version":"1.0.0.54"}],"InstallationDependency":{},"Name":"AMD PSHED Plug-in service for Microsoft Windows Server 2022 and 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"amdpshed.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d2b1724c510a4764bb242a2ef6","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A55","A56","A55","A56","A42","A42","A40","A42","A43","A43","A43","A41","A47","A48","A46","A58","HPE Cray XD295v","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900345","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"e42e9ca3a56752b35290c54f5c99d28f2ea8456c","SHA256Sum":"a8c79f0fbd466c17bed0faba8683185c4d06eea3c865abac1dd221a6361443c7","SHA512Sum":"b90e09bf70a90280b7b69576037e6395bc33ed1cc3a57b06847fa7c0a8d550c10906329c4511581ec01139fadc4dec175a6da7f8079f8ba163e3f2065f895a96"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.signed","20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653106A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"e42e9ca3a56752b35290c54f5c99d28f2ea8456c","SHA256Sum":"a8c79f0fbd466c17bed0faba8683185c4d06eea3c865abac1dd221a6361443c7","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900345"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 MCX653106A-HDAT Adapter :  HPE part numbers P31324-B21 and P31324-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653106A-HDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7dbaac55fac4085ac7ee79631","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15900345"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Files":[{"Checksum":[{"Filename":"CP070908.zip","SHA1Sum":"6f03975dcb89e22f7b9e509db76174e082c58bc8","SHA256Sum":"824af853f15bd1608d3250df708644588dd73de2efb1268ab68b8c5e519ae22d","SHA512Sum":"1732b48d5aa34b2e4318433fe19e59c7b57a65d9c4baf811f846644f96b7800bbb89e4df8d78c5aa2c0e0b30be7a40362c554bb185f33dd1167b3426bb6b9845"}],"ComponentSizeInKB":22717,"CompsigList":["CP070908.compsig"],"FileList":["/CP070908_BUILD_4.data","/CP070908.vmexe64","/CP070908.vmfile","/CP070908_VMw.zip","/CP070908.xml","/payload.json","/CP070908_VMw.zip/index.xml","/CP070908_VMw.zip/vendor-index.xml","/CP070908_VMw.zip/metadata.zip","/CP070908_VMw.zip/vib20/CP070908/HPE_bootbank_CP070908_85032G00.4-8.0.0.20613240.vib","/CP070908_VMw.zip/metadata.zip/vendor-index.xml","/CP070908_VMw.zip/metadata.zip/vmware.xml","/CP070908_VMw.zip/metadata.zip/vibs/CP070908--8879540849907203519.xml","/CP070908_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070908_85032G00.4-8.0.0.20613240.xml"],"Name":"CP070908.zip","SHA1Sum":"6f03975dcb89e22f7b9e509db76174e082c58bc8","SHA256Sum":"824af853f15bd1608d3250df708644588dd73de2efb1268ab68b8c5e519ae22d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00","VibList":[{"Name":"CP070908","Version":"85032G00.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - VS000480KXALB, VS000960KWXFN, VS001920KWXFP and VS003840KWXFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_120d6a8b3ce745a199c5db2d35","SupportedDevices":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-238.1.165.0-sles15sp6.x86_64.rpm","SHA1Sum":"1e225b362a03addf2fa3c996851bfc7e7951fc2c","SHA256Sum":"4eb15d204402c964a96df67bb29d25a665f5e2673f271f0ce90d8c5c45102599","SHA512Sum":"dc95dee03fa38b1839f7a00f47f41530653d43fde19738526669668ffbc3aad75efc65f913d0a98ff7e8b45c63ee297f5123040ef677f89bf8f063fe8ac16210"}],"ComponentSizeInKB":55,"CompsigList":["libbnxt_re-238.1.165.0-sles15sp6.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-238.1.165.0.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/lib64/pkgconfig/libbnxt_re.pc","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-238.1.165.0-sles15sp6.x86_64.rpm","SHA1Sum":"1e225b362a03addf2fa3c996851bfc7e7951fc2c","SHA256Sum":"4eb15d204402c964a96df67bb29d25a665f5e2673f271f0ce90d8c5c45102599","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP6","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cb5efda53f8d4b65b36a7441ff","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM3 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM3_1.28_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"9675b54e-1c96-44c3-a7a1-901503000000","Version":"1.28"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM3_1.28_A.fwpkg","SHA1Sum":"fd198df6753fab882d477fc5a2573dd1893a1362","SHA256Sum":"ba3ecb097892ab9b9868980e9683c767c5092b9c7c25b49cb118253c0f6b9bcf","SHA512Sum":"63080d700a7638b7ffc4a34ff7f80b9ce4f6c59efc00baf523c4a50e197a41527e08f2a6921d17f7218373498408e85e30e258528067a013fcd3cb4967915cba"}],"ComponentSizeInKB":56,"CompsigList":[],"FileList":["HPE_UBM3_1.28_A.HPb"],"Name":"HPE_UBM3_1.28_A.fwpkg","SHA1Sum":"fd198df6753fab882d477fc5a2573dd1893a1362","SHA256Sum":"ba3ecb097892ab9b9868980e9683c767c5092b9c7c25b49cb118253c0f6b9bcf","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901503000000"],"TypeOfChange":"1","Version":"1.28"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"Name":"Firmware Package - UBM3 Backplane PIC PLDM Firmware for Gen10 and Gen10 Plus /Gen11/Gen12 servers usage","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM3PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_26823546f53e42318902068da7","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0"]},{"OS":"Linux","Version":["8.0","15.0","9.0","7.0","12.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I45","A55","A55","A56","A56","U54","U54","U63","U58","U54","U63","U59","A42","U46","A42","U46","A43","A43","A43","U48","U50","A42","U61","U60","U46","U39","U71","U71","U68","U68","U72","U68"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U61_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.70 (08/20/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u61-2.70_2026_08_20-1.1.x86_64.rpm","SHA1Sum":"82fc4478bd1cd29ba0fae7fcd2d3bf873133758b","SHA256Sum":"40f9c3ff56cf5e39edaef24f8acec166f4ba4cb0dd334bc834e0275b5d0c57e3","SHA512Sum":"6f9cfbe518aa14b621f5ea8eb0cd5a62fae2bbf4bf424320537c774d43aebd2724cfd1a8731a943f092e619210a6144de6406c96d2e5baf7e779703eda86c1a0"}],"ComponentSizeInKB":16780,"CompsigList":["firmware-system-u61-2.70_2026_08_20-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.70_2026_08_20-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.70_2026_08_20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.70_2026_08_20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.70_2026_08_20-1.1/CP073279.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.70_2026_08_20-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.70_2026_08_20-1.1/U61_2.70_08_20_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.70_2026_08_20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.70_2026_08_20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u61-2.70_2026_08_20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073279.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073279.scexe"],"Name":"firmware-system-u61-2.70_2026_08_20-1.1.x86_64.rpm","SHA1Sum":"82fc4478bd1cd29ba0fae7fcd2d3bf873133758b","SHA256Sum":"40f9c3ff56cf5e39edaef24f8acec166f4ba4cb0dd334bc834e0275b5d0c57e3","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.70_08-20-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 Plus Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b97c71f8d15e428aa53025dd7c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A47_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071582.exe","SHA1Sum":"85e214195843046490dd2f7dccea5a1a5cb987a9","SHA256Sum":"a95aa78c296b0037053f70a0647b8470b86e2257a033c39f8c47fa3dc18645a1","SHA512Sum":"07da38cb213a7aa30de9f4a75e817c9fe599c74321e1f4f1000c47b44411e77d725ab9736766d97c1dce3072723cf239c52200fd6f591f9718ab19ea826e3e0d"}],"ComponentSizeInKB":33435,"CompsigList":["cp071582_part1.compsig","cp071582_part2.compsig"],"FileList":["A47_4.04_04_02_2026.signed.flash","cp071582.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071582.exe","SHA1Sum":"85e214195843046490dd2f7dccea5a1a5cb987a9","SHA256Sum":"a95aa78c296b0037053f70a0647b8470b86e2257a033c39f8c47fa3dc18645a1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2d413d2a7d664cd08900d49001","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A47","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U44_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072035.exe","SHA1Sum":"7f7605e94ca39113ac0f6d74b52d2de581ae04cc","SHA256Sum":"0ac5c89b7b387ab2765e950992089fc5195c77a70e6fde76a5f220b7fd66fb36","SHA512Sum":"7f5cb205ddc90985a554fe9916c6ff0dc2b6a18a5409c5f778cb0ea43e3aa8d14096c2de7356e439cb1b46af3275ac8bc31b1276ad2267d2c47d3dd9f414753a"}],"ComponentSizeInKB":8923,"CompsigList":["cp072035.compsig"],"FileList":["cp072035.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U44_3.76_05_28_2026.signed.flash"],"Name":"cp072035.exe","SHA1Sum":"7f7605e94ca39113ac0f6d74b52d2de581ae04cc","SHA256Sum":"0ac5c89b7b387ab2765e950992089fc5195c77a70e6fde76a5f220b7fd66fb36","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 (U44) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b764aeb04cc741458bcfaa7a03","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U44"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070839.zip","SHA1Sum":"47c4de1d9de7d302bc1d5465809472134a2b4a27","SHA256Sum":"386244994d838c243376052a143d79a3d3b8a63a573f582e9b20edd68f049147","SHA512Sum":"938e662d13f4a214cd7d1ce630bcfac87be2fb15decfd8194fa3a1db3390d2eb362d8b1c4ca7e38c6de555261c9d665310532946473300676c15ca43a0e843c7"}],"ComponentSizeInKB":7017,"CompsigList":["cp070839.compsig"],"FileList":["/cp070839.xml","/amsdComponent_802.11.13.0.1-1.zip","/amsdComponent_802.11.13.0.1-1.zip/index.xml","/amsdComponent_802.11.13.0.1-1.zip/vendor-index.xml","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip","/amsdComponent_802.11.13.0.1-1.zip/vib20/amsd/HPE_bootbank_amsd_802.11.13.0.1-1OEM.802.0.0.22380479.vib","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip/vendor-index.xml","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip/vmware.xml","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip/vibs/amsd--2353574801284761738.xml","/amsdComponent_802.11.13.0.1-1.zip/metadata.zip/bulletins/amsdComponent_802.11.13.0.1-1.xml"],"Name":"cp070839.zip","SHA1Sum":"47c4de1d9de7d302bc1d5465809472134a2b4a27","SHA256Sum":"386244994d838c243376052a143d79a3d3b8a63a573f582e9b20edd68f049147","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.2"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e6a28ab"],"TypeOfChange":"1","Version":"2026.03.01","VibList":[{"Name":"amsd","Version":"802.11.13.0.1-1OEM.802.0.0.22380479"}]}],"InstallationDependency":{},"Name":"HPE Agentless Management Bundle Smart Component on ESXi for Gen10 and Gen10 Plus Servers","PackageFormat":"","PerDeviceInstallTimeSeconds":200,"RebootRequired":"yes","SWKeys":[{"Name":"amsdComponent:802.11.13.0.1-1","SWKeyExpectedPath":"software.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_498cb3dbd619486f92d80c88ed","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","A40","U30","U32","U41","U33","U37","U38","U38","I43","I42","U40","A41","U43","U44","A42","A43","U31","U31","U39","A46","U48","U46","U46","U50","U47","U47","I44","A42","A43","A43","A42","U61","U60","A48","A47","U45","U46","U56","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52008TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"CP072404.zip","SHA1Sum":"dc3fa96c9d762aa6daa385aa6c79435df2bb97a0","SHA256Sum":"e754efa2d7f3485f654140cf2e8805c032b8a519bc3d25c3ba2486b8ab8cfe11","SHA512Sum":"0cd34e7d383f64ac664eaf114e4680ec0a72fc216e1a9327e83d7d07b7653549d084e3f8a9f8c21d10238fd67832ebd5557441e513d1fb6ffa8dff7aaa5da309"}],"ComponentSizeInKB":17947,"CompsigList":["CP072404.compsig"],"FileList":["/CP072404_BUILD_1.data","/CP072404.vmexe64","/CP072404.vmfile","/CP072404_VMw.zip","/CP072404.xml","/payload.json","/CP072404_VMw.zip/index.xml","/CP072404_VMw.zip/vendor-index.xml","/CP072404_VMw.zip/metadata.zip","/CP072404_VMw.zip/vib20/CP072404/HPE_bootbank_CP072404_HPG4.1-8.0.0.20613240.vib","/CP072404_VMw.zip/metadata.zip/vendor-index.xml","/CP072404_VMw.zip/metadata.zip/vmware.xml","/CP072404_VMw.zip/metadata.zip/vibs/CP072404-2651325455436991480.xml","/CP072404_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072404_HPG4.1-8.0.0.20613240.xml"],"Name":"CP072404.zip","SHA1Sum":"dc3fa96c9d762aa6daa385aa6c79435df2bb97a0","SHA256Sum":"e754efa2d7f3485f654140cf2e8805c032b8a519bc3d25c3ba2486b8ab8cfe11","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3730-3638-30475753584e"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP072404","Version":"HPG4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK007680GWSXN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK007680GWSXN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_36e2676305f04e409c8604c948","SupportedDevices":["562340a5-304b-3730-3638-30475753584e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.1","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"bnxt_en-kmp-default-1.10.3_k6.12.0_160000.5-238.1.165.0.sles16sp0.x86_64.rpm","SHA1Sum":"cb8aaf464a4dbbfe111499e9007ea33f20fdcccc","SHA256Sum":"76aa422b3a8f62aa1c5833700b4d74597f7f277a07d9d6ae79b3537158ac36e8","SHA512Sum":"2ac05f06728c34ea5beba220216763b75585edd902004b036e5fb3e74f572cfa9ae2d1f1498843539994da898fdf3709feac68d409bd0c7de9b02a8694b7a0c3"}],"ComponentSizeInKB":1401,"CompsigList":["bnxt_en-kmp-default-1.10.3_k6.12.0_160000.5-238.1.165.0.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/bnxt_en.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"Name":"bnxt_en-kmp-default-1.10.3_k6.12.0_160000.5-238.1.165.0.sles16sp0.x86_64.rpm","SHA1Sum":"cb8aaf464a4dbbfe111499e9007ea33f20fdcccc","SHA256Sum":"76aa422b3a8f62aa1c5833700b4d74597f7f277a07d9d6ae79b3537158ac36e8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3bc93f14d9ef402887cc726e6c","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52008TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"cp072163.exe","SHA1Sum":"ccfefca604cc0292aa993cd44d805efea150feec","SHA256Sum":"b82f0d23053850f41bea49b229463dd399add45c173970daa1147d2e1cdb57f5","SHA512Sum":"0c2d22cf804b60b99451ab37e2796728a9567fb18b1106feb83edf0f9807d367b3ec479491ccf27c468a46df6e267eb5dc57e969bca72b43c2b312999006c652"}],"ComponentSizeInKB":3306,"CompsigList":["cp072163.compsig"],"FileList":["cp072163.xml","cpqsetup.exe","M52008TBHPG4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp072163.exe","SHA1Sum":"ccfefca604cc0292aa993cd44d805efea150feec","SHA256Sum":"b82f0d23053850f41bea49b229463dd399add45c173970daa1147d2e1cdb57f5","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3730-3638-30475753584e"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK007680GWSXN  Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK007680GWSXN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_638ff21e174945ac903ef45f09","SupportedDevices":["562340a5-304b-3730-3638-30475753584e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100","10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071253.exe","SHA1Sum":"cbd91c537cacbf3c6c5eb2981fe111e4a77d2b18","SHA256Sum":"1986237b3e15a5b9c307dccf07308f00efbb206810d5c0fc11a6f85898d8fa79","SHA512Sum":"2485b52af0297595d685a33abc796de118791c170c4134e1c403edef066073fd4fbaac3e3bbcba7c214a271abfbfbcd5ccd224fb98cdeba769be68b173e95c35"}],"ComponentSizeInKB":1722,"CompsigList":["cp071253.compsig"],"FileList":["cp071253.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"Name":"cp071253.exe","SHA1Sum":"cbd91c537cacbf3c6c5eb2981fe111e4a77d2b18","SHA256Sum":"1986237b3e15a5b9c307dccf07308f00efbb206810d5c0fc11a6f85898d8fa79","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a1001a256ded40b9b7c42a5bb4","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9ad359dac1-HPDB-5.1.x86_64.rpm","SHA1Sum":"14041dc9441d51b991ae6df6f72ebc0a1c49f39f","SHA256Sum":"af3b72a13526c8d4f1efb6a3cc348f20cd4cd8f4044e559501322b932703775e","SHA512Sum":"cf56a9a1e1bfd5a28f8247765b1e90f59af058a2bb991b13b4243d0a36dc2511d48bd19d38076f08a7fe6fc5755da5084c2ef2dcf0db823098829744cbd53b3f"}],"ComponentSizeInKB":5017,"CompsigList":["firmware-hdd-9ad359dac1-HPDB-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/CP068919.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/KAPM5ALSHPDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068919.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068919.scexe"],"Name":"firmware-hdd-9ad359dac1-HPDB-5.1.x86_64.rpm","SHA1Sum":"14041dc9441d51b991ae6df6f72ebc0a1c49f39f","SHA256Sum":"af3b72a13526c8d4f1efb6a3cc348f20cd4cd8f4044e559501322b932703775e","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d11dc139e4384368a01dad3045","SupportedDevices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"CP070907.zip","SHA1Sum":"88abb62eb7a0dacea43ddf88264fbaad68478beb","SHA256Sum":"3e328df1020bdcd16c62f11f074f4ce26710dc75b589df1847e13002517853fa","SHA512Sum":"1846b33f7bcb7b50e28dbe31771d7dbdae0cbdd16ed6430f4307af3c6ef0e1e44631b1bab1187183d3b1117186668a8bae18ed0b337ec44bd337867c87505e0e"}],"ComponentSizeInKB":22034,"CompsigList":["CP070907.compsig"],"FileList":["/CP070907_BUILD_2.data","/CP070907.vmexe64","/CP070907.vmfile","/CP070907_VMw.zip","/CP070907.xml","/payload.json","/CP070907_VMw.zip/index.xml","/CP070907_VMw.zip/vendor-index.xml","/CP070907_VMw.zip/metadata.zip","/CP070907_VMw.zip/vib20/CP070907/HPE_bootbank_CP070907_HPK5.2-8.0.0.20613240.vib","/CP070907_VMw.zip/metadata.zip/vendor-index.xml","/CP070907_VMw.zip/metadata.zip/vmware.xml","/CP070907_VMw.zip/metadata.zip/vibs/CP070907--7255520009019874989.xml","/CP070907_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070907_HPK5.2-8.0.0.20613240.xml"],"Name":"CP070907.zip","SHA1Sum":"88abb62eb7a0dacea43ddf88264fbaad68478beb","SHA256Sum":"3e328df1020bdcd16c62f11f074f4ce26710dc75b589df1847e13002517853fa","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5","VibList":[{"Name":"CP070907","Version":"HPK5.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e2c4dff857fb48b7a0f421efe2","SupportedDevices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-4fbb6d96e5_0HPG3-2.1_amd64.deb","SHA1Sum":"7540c03777763ae4ebd8708b518ffe3e6be1e3ee","SHA256Sum":"11c3f02eb36daf617da9245579130669c2d6db69707655d04d3968be45bd7ecb","SHA512Sum":"b508dff6f2e0664c4d844a05093a46cd97c01855c4fd83eb31ca3f36add5010ced43a203263346f5cd1a8fe8340f89c38848125e0bfd0d15caacb4f87d48c0e8"}],"ComponentSizeInKB":4221,"CompsigList":["firmware-hdd-4fbb6d96e5_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/CP071782.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/SHPEEVSBPTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071782.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071782.scexe"],"Name":"firmware-hdd-4fbb6d96e5_0HPG3-2.1_amd64.deb","SHA1Sum":"7540c03777763ae4ebd8708b518ffe3e6be1e3ee","SHA256Sum":"11c3f02eb36daf617da9245579130669c2d6db69707655d04d3968be45bd7ecb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8f64ad823176400d8fac4ddddb","SupportedDevices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.rpm","SHA1Sum":"4cb77d06a6e19daf624910341cea6204200ac0ae","SHA256Sum":"dbbc39f3c72d8ef082ce4720896aeeb1cb3064bf6048a27f6edd8ea8395ef2f7","SHA512Sum":"adbbdbd5b633189f2e0a617df68c394da29195cf18ac35dda9dab0e77d05dd68ecc79cc502ce6b57cf793b6b641a663d3a85b806db09f2696ab9b79761466d2e"}],"ComponentSizeInKB":2649,"CompsigList":["mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/compat","./lib/modules/6.4.0-150700.51-default/updates/compat/mlx_compat.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers","./lib/modules/6.4.0-150700.51-default/updates/drivers/block","./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd","./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd/rnbd-client.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/block/rnbd/rnbd-server.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/fwctl.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/efa","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/erdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/erdma/erdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/irdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mana","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mthca","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qedr","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qib","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/usnic","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rxe","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/siw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/iser","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/isert","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srp","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.4.0-150700.51-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/host","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/target","./lib/modules/6.4.0-150700.51-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa","./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci/mlx5","./lib/modules/6.4.0-150700.51-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.4.0-150700.51-default/updates/net","./lib/modules/6.4.0-150700.51-default/updates/net/9p","./lib/modules/6.4.0-150700.51-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/mlxdevm","./lib/modules/6.4.0-150700.51-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/6.4.0-150700.51-default/updates/net/rds","./lib/modules/6.4.0-150700.51-default/updates/net/rds/rds_rdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/smc","./lib/modules/6.4.0-150700.51-default/updates/net/smc/smc.ko","./lib/modules/6.4.0-150700.51-default/updates/net/smc/smc_diag.ko","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.4.0-150700.51-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"Name":"mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150700.51-OFED.26.04.0.8.6.1.1.sles15sp7.x86_64.rpm","SHA1Sum":"4cb77d06a6e19daf624910341cea6204200ac0ae","SHA256Sum":"dbbc39f3c72d8ef082ce4720896aeeb1cb3064bf6048a27f6edd8ea8395ef2f7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.rpm","SHA1Sum":"cba73ba1dec86b41984dd97bc3b4a9dac015aac7","SHA256Sum":"74430350cd0ba2f0a1b6311267268a04e7598b6cf061b0fb8f40f65498e6c187","SHA512Sum":"d7bb9eaa6582e01046d31ea9ec9bd2c8c2990d85414df655b7294f98f6809f9ce6b4188e1aec08ea818db89d09bd4c43a6e0baeb08708ebe878c76d3ffc78063"}],"ComponentSizeInKB":9997,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.8.84","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.8.84","./usr/share/doc/packages/libvma-9.8.84/CHANGES","./usr/share/doc/packages/libvma-9.8.84/README","./usr/share/doc/packages/mlnx-ofa_kernel","./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/perftest","./usr/share/doc/packages/perftest/COPYING","./usr/share/doc/packages/perftest/README","./usr/share/doc/packages/perftest/runme","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/libvma","./usr/share/licenses/libvma/LICENSE","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp7.x86_64.rpm","SHA1Sum":"cba73ba1dec86b41984dd97bc3b4a9dac015aac7","SHA256Sum":"74430350cd0ba2f0a1b6311267268a04e7598b6cf061b0fb8f40f65498e6c187","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for SUSE LINUX Enterprise Server 15 SP7 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_afe47bd448d349a6b34cfba8f1","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","A72","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Files":[{"Checksum":[{"Filename":"firmware-d3000-6.00-12.1.x86_64.rpm","SHA1Sum":"e6e7c86d19b8abc2958c8b6cbc74cce77f187093","SHA256Sum":"29ba6620302490b2f5b4f19404e502b90a530aff98b51973cb42e4cd4a3912bd","SHA512Sum":"45d2b46d4ccdd3dc018640721d35f94cb07275a9d0e0af9d6a37841f3b845a9c3847811c88de533f654d718334b60523b745565c82df6b2b0f18d42479564e81"}],"ComponentSizeInKB":3545,"CompsigList":["firmware-d3000-6.00-12.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/CP072208.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/Reveille-Release-6.00-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-12.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072208.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072208.scexe"],"Name":"firmware-d3000-6.00-12.1.x86_64.rpm","SHA1Sum":"e6e7c86d19b8abc2958c8b6cbc74cce77f187093","SHA256Sum":"29ba6620302490b2f5b4f19404e502b90a530aff98b51973cb42e4cd4a3912bd","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c0128085a662490d80d8a1560b","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","9.0","15.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U44_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"U44_3.76_05_28_2026.fwpkg","SHA1Sum":"d45f05e1f405da0c05411147c993f70dc67c3271","SHA256Sum":"ac1a67a39d9c7440cfaf9dc9c36334727d8c6ba90a70677f7579cd4b016c2ef2","SHA512Sum":"e32f071724bfdbfbe5cd4a31c02ca87f0d4e6ce6f8807d7de70868bcf52ff1d43997553217e894600fddc2117b838ee8c14ba3aede8a6e4ed1a042e35f3422cc"}],"ComponentSizeInKB":16430,"CompsigList":[],"FileList":["payload.json","U44_3.76_05_28_2026.signed.flash","U44_3.76_05_28_2026.xml"],"Name":"U44_3.76_05_28_2026.fwpkg","SHA1Sum":"d45f05e1f405da0c05411147c993f70dc67c3271","SHA256Sum":"ac1a67a39d9c7440cfaf9dc9c36334727d8c6ba90a70677f7579cd4b016c2ef2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 (U44) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b67e14c5d79b416eb65938030b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U44"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd-5.1.0-2197.8.rhel9.x86_64.rpm","SHA1Sum":"5a9223dba116f159dde199883a00dce373fb7848","SHA256Sum":"6fe6593319371eb7854eca774fa4cfc09ea596f3ea22eeebe5af1c36f34a737f","SHA512Sum":"126dc6a9269a23c3befaad7623afbaaff3d2d043480cd02d16acb5131d569e42507d71d8d56e093a04f41e9698f04844e6856fa25c4cfe07e73e692bc6b7c291"}],"ComponentSizeInKB":11707,"CompsigList":["amsd-5.1.0-2197.8.rhel9.x86_64.compsig"],"FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/51","./usr/lib/.build-id/51/12e33499e4b7cd784a542d295dadbb87d64fd9","./usr/lib/.build-id/51/12e33499e4b7cd784a542d295dadbb87d64fd9.1","./usr/lib/.build-id/5b","./usr/lib/.build-id/5b/d5ffe124f36fbfc7d09a923d4168e40b4cf515","./usr/lib/.build-id/5b/d5ffe124f36fbfc7d09a923d4168e40b4cf515.1","./usr/lib/.build-id/60","./usr/lib/.build-id/60/2ccdbca92ff67fbe7752b49a8b64502c804309","./usr/lib/.build-id/b6","./usr/lib/.build-id/b6/be2629743b8ed9c3a983b9f2d05a9220d1732f","./usr/lib/.build-id/b6/be2629743b8ed9c3a983b9f2d05a9220d1732f.1","./usr/lib/.build-id/b9","./usr/lib/.build-id/b9/2090b1c033f69032cd066584fd187a6bc8b2e0","./usr/lib/.build-id/b9/2090b1c033f69032cd066584fd187a6bc8b2e0.1","./usr/lib/.build-id/ca","./usr/lib/.build-id/ca/209976e8587f98232787e00cc0800cea0173a2","./usr/lib/.build-id/d7","./usr/lib/.build-id/d7/76cffd717856078cad4ed3dafc7cd963a0c7b1","./usr/lib/.build-id/d7/76cffd717856078cad4ed3dafc7cd963a0c7b1.1","./usr/lib/.build-id/f6","./usr/lib/.build-id/f6/6a132269768201db263bd5845ab1f0fb668ca9","./usr/lib/.build-id/f6/6a132269768201db263bd5845ab1f0fb668ca9.1","./usr/lib/.build-id/fd","./usr/lib/.build-id/fd/8a5f8df84ce0245466055429656abcc773e14f","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"Name":"amsd-5.1.0-2197.8.rhel9.x86_64.rpm","SHA1Sum":"5a9223dba116f159dde199883a00dce373fb7848","SHA256Sum":"6fe6593319371eb7854eca774fa4cfc09ea596f3ea22eeebe5af1c36f34a737f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"5.1.0"}],"InstallationDependency":{},"Name":"Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 9 Server","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b8d1e080121f47f588b033e7ff","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-103c-330615903307","a6b1a447-382a-5a4f-103c-330715903307","a6b1a447-382a-5a4f-103c-3307159004bd","a6b1a447-382a-5a4f-103c-3306159004bd"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U43","U41","U33","U44","A47","A48","U40","U47","U45","U24","U37","A46","U47","U38","U38","A45","U50","U46","I43","I45","I44","I42","A42","U54","U54","U54","U61","U60","U58","U58","U63","U63","A55","A55","A56","A56","U59","U64","U58","U62","U57","U65","U65","A58","U69","U69","H11","U71","U72","U68","U68","U68","U66","U71","U68","I46","U72","U70","A59","U73","A66","A66","U74","U77","U71","U77","U83","A72"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-fastlinq-kmp-default-8.76.6.0_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"b346fefce2b90362f8e0f29711cec894ac0a5a67","SHA256Sum":"d918f5eefc143f5196f024a5fcee1d8eeaa55e830829bbd878d20b06982a5799","SHA512Sum":"4c43f469628bc8588e6ee50f048f9ab512e0f4274953cde934b2bb178ccf0455886fd71f9e4b45e78a721d5912fb2ee7e8be4eb0753a218d786fc3a0469a5de3"}],"ComponentSizeInKB":17516,"CompsigList":["qlgc-fastlinq-kmp-default-8.76.6.0_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/fastlinq.conf","./usr/lib/firmware/qed","./usr/lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qed.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qede.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qedf.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qedi.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"Name":"qlgc-fastlinq-kmp-default-8.76.6.0_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"b346fefce2b90362f8e0f29711cec894ac0a5a67","SHA256Sum":"d918f5eefc143f5196f024a5fcee1d8eeaa55e830829bbd878d20b06982a5799","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.76.6.0-1"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_423ac98116b245debe3d53dd4c","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVLAWBA0HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ca21e169e2_0HPG5-2.1_amd64.deb","SHA1Sum":"a90556c4aecd251dbbbc81235c831bec16391fce","SHA256Sum":"03e6f4fe3edaa5e0e2f4f126f88a3d9b28d152e95492988f548863c7d711b767","SHA512Sum":"79b04b46b3ba37d6cb282017008971f6eca1a5359bf50780615c3097ba08fc8d09d971dce44024316ad253c138b307dbfeb8b71cd36f241c7653a54ef8c48db1"}],"ComponentSizeInKB":4680,"CompsigList":["firmware-hdd-ca21e169e2_0HPG5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/CP073207.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/WVLAWBA0HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073207.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073207.scexe"],"Name":"firmware-hdd-ca21e169e2_0HPG5-2.1_amd64.deb","SHA1Sum":"a90556c4aecd251dbbbc81235c831bec16391fce","SHA256Sum":"03e6f4fe3edaa5e0e2f4f126f88a3d9b28d152e95492988f548863c7d711b767","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000GWKGV Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1f26ecc571de4350a6175d5125","SupportedDevices":["4d2340a5-3042-3430-3030-3047574b4756"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.rpm","SHA1Sum":"e461016954ad2eb9545afbaa7c8add4da6303776","SHA256Sum":"5c7c8916c5e01acc8d310197b0246382b6ed8699755247d01f2fbf79b65c6f9a","SHA512Sum":"17a2c0da8c83835bf6ddf5635e5cdf445143cdad61149e92dfc521e5f65317c71c888617759341b34802ba824044eabc65677aa0aa27091f018d84226e8bc06e"}],"ComponentSizeInKB":847,"CompsigList":["HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.compsig"],"FileList":["./opt/QLogic_Corporation/qlogic-libs","./opt/QLogic_Corporation/qlogic-libs/README.LIBQLSDM","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-aarch64.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-ppc64le.so","./opt/QLogic_Corporation/qlogic-libs/libqlsdm-x86_64.so","./opt/QLogic_Corporation/qlogic-libs/ql-hba-collect-1.12.tgz","./usr/share/smartupdate/HPE-CNA-FC-hpeqlgc-Enablement-Kit/component.xml"],"Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit-6.0.0.1-4.noarch.rpm","SHA1Sum":"e461016954ad2eb9545afbaa7c8add4da6303776","SHA256Sum":"5c7c8916c5e01acc8d310197b0246382b6ed8699755247d01f2fbf79b65c6f9a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1"],"TypeOfChange":"1","Version":"6.0.0.1-4"}],"InstallationDependency":{},"Name":"HPE QLogic Fibre Channel Enablement Kit for Host Bus Adapter for Linux","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_10f65b3327384eed803da4c0f1","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK007680GWSXN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52008TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475753584e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b460823f70_0HPG4-1.1_amd64.deb","SHA1Sum":"78bbdb2d11b1ce871f22a194281924ec0d42af71","SHA256Sum":"5e05e17611f34e78bd9789f075eadc595a73ab598de901e4db55ff1f12d510ba","SHA512Sum":"a6f4b67db00b533a526e8d0ebb5eb5e6e7c0d24fa35905326701a847c41d01ee80eded1d78e02dbc517394176cb778ba8cfa81a9a59d0eb2771d92e14a2c148b"}],"ComponentSizeInKB":3579,"CompsigList":["firmware-hdd-b460823f70_0HPG4-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/CP072241.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/M52008TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072241.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-b460823f70-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072241.scexe"],"Name":"firmware-hdd-b460823f70_0HPG4-1.1_amd64.deb","SHA1Sum":"78bbdb2d11b1ce871f22a194281924ec0d42af71","SHA256Sum":"5e05e17611f34e78bd9789f075eadc595a73ab598de901e4db55ff1f12d510ba","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3730-3638-30475753584e"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK007680GWSXN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK007680GWSXN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_40c1537c74174c718412997159","SupportedDevices":["562340a5-304b-3730-3638-30475753584e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for MicroServerv2 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SC_MicroServerv2GEN10Plus_ME_06.00.03.708.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"SC_MicroServerv2GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"7fc963a27abbd8eba6bf6cb9eb57acb085964666","SHA256Sum":"a27a28c7a3bd3e5164c36ee0c0d5579fe58568f6344df3501274f34e69c43306","SHA512Sum":"97ae7f24cc433f4cf17c146d7123160863d9e045da93efbb789da47b71a086842c285d41c7c211c2ba598729b9568e39207361f61bc53c8293a4150cb9189f2c"}],"ComponentSizeInKB":2234,"CompsigList":[],"FileList":["payload.json","SC_MicroServerv2GEN10Plus_ME_06.00.03.708.signed.bin","SC_MicroServerv2GEN10Plus_ME_06.00.03.708.xml"],"Name":"SC_MicroServerv2GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"7fc963a27abbd8eba6bf6cb9eb57acb085964666","SHA256Sum":"a27a28c7a3bd3e5164c36ee0c0d5579fe58568f6344df3501274f34e69c43306","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2 Servers","PackageFormat":"FWPKG","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6dc28615340a479fa280db1614","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U64"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.23"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.23"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.23"}]},"Files":[{"Checksum":[{"Filename":"cp071764.exe","SHA1Sum":"4a8a628646fd6fc57be701ace356f9295a9638da","SHA256Sum":"e476357d28a610ab0b2225cc88ca0d8840f7b4c853cb06f1a65da0d2f0c537d5","SHA512Sum":"37aebdb0b1eff0f8b738e3a0e67a4e83c69529c3c0129cc93d4fe8be25d2033557664936061cc8f00394df9e83009a82fc43d7c318440989f4188ac6303dd25d"}],"ComponentSizeInKB":7600,"CompsigList":["cp071764.compsig"],"FileList":["cp071764.xml","cpqsetup.exe","HPE_luxor_8.23.bin.fw","payload.json","setup.dll"],"Name":"cp071764.exe","SHA1Sum":"4a8a628646fd6fc57be701ace356f9295a9638da","SHA256Sum":"e476357d28a610ab0b2225cc88ca0d8840f7b4c853cb06f1a65da0d2f0c537d5","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.23"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_53dafc484b2b4a988ac636754c","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["A41","A40"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLHCWBA0HPG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"cp072239.exe","SHA1Sum":"2ab6fc9ca9652ad6a1b9328bc4d86629e61518d6","SHA256Sum":"7669c6465ab253de78752bee6987050ed4227812adf4c3cd456df8c5ad9508c4","SHA512Sum":"6c7468ce2264c7d29efe47bff3befec2bc7b498c8e37c275c791f5647efd508496f1ea36e5e78655d873c6a6a018f736c9b4b1dccaf149d6063f52efa984201b"}],"ComponentSizeInKB":4345,"CompsigList":["cp072239.compsig"],"FileList":["cp072239.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLHCWBA0HPG6.rel"],"Name":"cp072239.exe","SHA1Sum":"2ab6fc9ca9652ad6a1b9328bc4d86629e61518d6","SHA256Sum":"7669c6465ab253de78752bee6987050ed4227812adf4c3cd456df8c5ad9508c4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000GWDFE Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_398e119217b248ff9b16429639","SupportedDevices":["4d2340a5-3042-3231-3030-304757444645"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 2p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30074","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","SHA1Sum":"8f0fffab96ea364b2d6ee3c2a0f443c66279bfcf","SHA256Sum":"faec77ce427f2b3dec5c7295c1e1fd326ab21b7a6367f8a016b0b70e689f3cb8","SHA512Sum":"ed0036ea9faa99964f5a804d83cb3f949e7c14bc0b0438cf1a55ebeb721b3027e96678b33f065539b9812a663d97012f236e979ee00a266fc8c3cb0f7585d2e7"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.signed","20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653106A-ECA_HPE_Ax.pldm.fwpkg","SHA1Sum":"8f0fffab96ea364b2d6ee3c2a0f443c66279bfcf","SHA256Sum":"faec77ce427f2b3dec5c7295c1e1fd326ab21b7a6367f8a016b0b70e689f3cb8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 2-port QSFP56 PCIe4 x16 MCX653106A-ECAT Adapter : HPE part numbers P23666-B21 and P23666-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653106A-ECAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c3a89bd3dd2e4858859f3d6ee5","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15b30074"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U54","U58","U58","U63","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL6WBA0HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"CP073213.zip","SHA1Sum":"621ee10706d85f40142721e7d7b1c351f411cc54","SHA256Sum":"8f7dc92653a85c7f5eaaae079064c9d537a4de88c64e6b0729c26d653d72fd46","SHA512Sum":"1326bd4e74570f58d02b0a2d235cc573fe715f16eab022a4993d12f7175c4a320146c3c092592146ea1fe2cbfd3aabe0c957ceb7ad2d887c43738f9bd6294c8d"}],"ComponentSizeInKB":20259,"CompsigList":["CP073213.compsig"],"FileList":["/CP073213_BUILD_1.data","/CP073213.vmexe64","/CP073213.vmfile","/CP073213_VMw.zip","/CP073213.xml","/payload.json","/CP073213_VMw.zip/index.xml","/CP073213_VMw.zip/vendor-index.xml","/CP073213_VMw.zip/metadata.zip","/CP073213_VMw.zip/vib20/CP073213/HPE_bootbank_CP073213_HPG5.1-8.0.0.20613240.vib","/CP073213_VMw.zip/metadata.zip/vendor-index.xml","/CP073213_VMw.zip/metadata.zip/vmware.xml","/CP073213_VMw.zip/metadata.zip/vibs/CP073213-6958846307700071853.xml","/CP073213_VMw.zip/metadata.zip/bulletins/Smart-Component-CP073213_HPG5.1-8.0.0.20613240.xml"],"Name":"CP073213.zip","SHA1Sum":"621ee10706d85f40142721e7d7b1c351f411cc54","SHA256Sum":"8f7dc92653a85c7f5eaaae079064c9d537a4de88c64e6b0729c26d653d72fd46","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP073213","Version":"HPG5.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWKGR Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0a20edd47cf146a29d54497932","SupportedDevices":["4d2340a5-3042-3630-3030-3047574b4752"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-3050584d544e","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-3050584d5456","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-3050584d5541","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-3050584d544c","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-3050584d5452","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-3050584d5454","Version":"HPD4"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALSHPD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-3050584d5455","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_PM7_KAPM7ALSHPD4.fwpkg","SHA1Sum":"8ffe7e5833092e4d4e0b4d96f87b73cabca0792e","SHA256Sum":"f46078c7a23e28323964baeab66839462e839feebb14d388c369f1683232cac5","SHA512Sum":"056b78b98f91e765d43fea575096b2a5d420b9cbbb6d6d3561ee2f8f5a59621c3946d3148790c38bbc1dd5d146ab281773f08f1bc19c2cc6d1a44f726446fd85"}],"ComponentSizeInKB":1539,"CompsigList":[],"FileList":["Kioxia_PM7_KAPM7ALSHPD4.HPb","Kioxia_PM7_KAPM7ALSHPD4.xml","payload.json"],"Name":"Kioxia_PM7_KAPM7ALSHPD4.fwpkg","SHA1Sum":"8ffe7e5833092e4d4e0b4d96f87b73cabca0792e","SHA256Sum":"f46078c7a23e28323964baeab66839462e839feebb14d388c369f1683232cac5","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-3050584d544e","4d2340a5-304f-3330-3230-3050584d5456","4d2340a5-304f-3630-3430-3050584d5541","562340a5-304f-3130-3932-3050584d544c","562340a5-304f-3330-3834-3050584d5452","562340a5-304f-3730-3638-3050584d5454","562340a5-304f-3531-3336-3050584d5455"],"TypeOfChange":"2","Version":"HPD4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600PXMTN, MO003200PXMTV, MO006400PXMUA, VO001920PXMTL, VO003840PXMTR, VO007680PXMTT and VO015360PXMTU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600PXMTN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003200PXMTV","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO006400PXMUA","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920PXMTL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PXMTR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PXMTT","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO015360PXMTU","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_773c466c982042fea8769d7ddb","SupportedDevices":["562340a5-304f-3531-3336-3050584d5455","562340a5-304f-3730-3638-3050584d5454","562340a5-304f-3330-3834-3050584d5452","562340a5-304f-3130-3932-3050584d544c","4d2340a5-304f-3630-3430-3050584d5541","4d2340a5-304f-3330-3230-3050584d5456","4d2340a5-304f-3130-3630-3050584d544e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ice-kmp-default-2.6.6_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"6b07bb965a209d6dd6d3629bce3d5b19707c763d","SHA256Sum":"30f4a1eaae98c65687cad70082e98a0a5d38912897a28a965dee1eea4340fb76","SHA512Sum":"e6ed2e6d847c19bdc65636434a90b623654fb173ae2fa4f8d7e6127087640b1bffb32ad763d6c10f6b99de91a2cc39240c425e2369fea58e879954ad3ac3f146"}],"ComponentSizeInKB":24278,"CompsigList":["ice-kmp-default-2.6.6_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/ice","./lib/modules/6.4.0-150600.21-default/updates/ice/ice.ko","./usr/share/doc/packages/ice","./usr/share/doc/packages/ice/COPYING","./usr/share/doc/packages/ice/README","./usr/share/doc/packages/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/ice-kmp-default/component.xml"],"Name":"ice-kmp-default-2.6.6_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"6b07bb965a209d6dd6d3629bce3d5b19707c763d","SHA256Sum":"30f4a1eaae98c65687cad70082e98a0a5d38912897a28a965dee1eea4340fb76","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"2.6.6-1"},{"Checksum":[{"Filename":"ice-kmp-default-2.6.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"d13051f9d33b5338b19d48d80ccce5acb173f388","SHA256Sum":"8e801db5029a349aad1afd9f4fca92a0b64af1f642a4163165c6ef66ff1447a8","SHA512Sum":"ae04a4200914ef20041b2760c310dc2636aab1280cf9734414be1a079b9c1c282d5cd6069951cbf418c796dab69585b7a614d674456f069fcfd989dcdd3ab85c"}],"ComponentSizeInKB":1128,"CompsigList":["ice-kmp-default-2.6.6_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/ice","./lib/modules/6.4.0-150700.51-default/updates/ice/ice.ko","./usr/share/doc/packages/ice","./usr/share/doc/packages/ice/COPYING","./usr/share/doc/packages/ice/README","./usr/share/doc/packages/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/ice-kmp-default/component.xml"],"Name":"ice-kmp-default-2.6.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"d13051f9d33b5338b19d48d80ccce5acb173f388","SHA256Sum":"8e801db5029a349aad1afd9f4fca92a0b64af1f642a4163165c6ef66ff1447a8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"2.6.6-1"}],"InstallationDependency":{},"Name":"Intel ice Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b3873fd253224088a232ecd921","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-579e80860001","a6b1a447-382a-5a4f-8086-579E80860000","a6b1a447-382a-5a4f-8086-12d380860007","a6b1a447-382a-5a4f-8086-124a80860001","a6b1a447-382a-5a4f-8086-124a80860008","a6b1a447-382a-5a4f-8086-124a80860004","a6b1a447-382a-5a4f-8086-124a80860002","a6b1a447-382a-5a4f-8086-124980860002","a6b1a447-382a-5a4f-8086-124980860005"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp067917.exe","SHA1Sum":"8e236b7c21bf411031e0a6bc878b1f598742fa17","SHA256Sum":"d24504e9f532e4921eb3bf54c9755aa2c30831e447c070eadf5482fe84a1d58d","SHA512Sum":"55815791fac06dcc6d10c907eed4cf6d7fbc25069507f2b83f374f1de197fb3a0b7eddd2111677e3fd4d8235a1d21c920215b6dce9c7eb5672b0edd60a26fccf"}],"ComponentSizeInKB":726,"CompsigList":["cp067917.compsig"],"FileList":["cp067917.xml","cpqsetup.exe","hpepqiesrv.dll","hpepqiesrv.exe","hpepqiesrv.msi"],"Name":"cp067917.exe","SHA1Sum":"8e236b7c21bf411031e0a6bc878b1f598742fa17","SHA256Sum":"d24504e9f532e4921eb3bf54c9755aa2c30831e447c070eadf5482fe84a1d58d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec74b19684"],"TypeOfChange":"1","Version":"1.2.1.69"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array S100i SR Gen10 SW RAID Driver version 62.0.28.64 or greater is required before attempting update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccaba7e59","SWKey":"SmartDQa.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"62.0.28.64"}]}]}]},"Name":"HPE Smart Array SR Event Notification Service for Windows Server 64-bit Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"hpepqiesrv.exe","SWKeyExpectedPath":"%programfiles%\\hpe\\hpepqiesrv"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ebffb2cdb5344b9b7b9694171","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0655","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0701","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-103c-193f159000e4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U30","U32","U37","I43","I42","U34","A40","U31","U31","U36","HPE ProLiant ML150 Gen10 Server","U33","U40","U38","U38","A43","U46","U46","U50","I44","U61","U60","U47","U47","A42","A43","A42","A48","A47","A46","HPE Apollo 6500 Gen10 Plus (Chassis)","U48","A42","A43","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Files":[{"Checksum":[{"Filename":"CP070930.zip","SHA1Sum":"fdd29a7323831e070e0e63d9613e770b0b680983","SHA256Sum":"babd2771ae43192ee1724227c10c1638b2b3095d73701aefc0717e62a08409ea","SHA512Sum":"4005e3b2347b710e14694eb7949aa793ed298490e38e7505e2ed6f344c7d5ed0ac96820385c5ef606a4d4547ee09426a34929a1e1aeb72ffc3465c7653b84557"}],"ComponentSizeInKB":20448,"CompsigList":["CP070930.compsig"],"FileList":["/CP070930_BUILD_10.data","/CP070930.vmexe64","/CP070930.vmfile","/CP070930_VMw.zip","/CP070930.xml","/payload.json","/CP070930_VMw.zip/index.xml","/CP070930_VMw.zip/vendor-index.xml","/CP070930_VMw.zip/metadata.zip","/CP070930_VMw.zip/vib20/CP070930/HPE_bootbank_CP070930_GPK6.10-8.0.0.20613240.vib","/CP070930_VMw.zip/metadata.zip/vendor-index.xml","/CP070930_VMw.zip/metadata.zip/vmware.xml","/CP070930_VMw.zip/metadata.zip/vibs/CP070930--2659174081554699061.xml","/CP070930_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070930_GPK6.10-8.0.0.20613240.xml"],"Name":"CP070930.zip","SHA1Sum":"fdd29a7323831e070e0e63d9613e770b0b680983","SHA256Sum":"babd2771ae43192ee1724227c10c1638b2b3095d73701aefc0717e62a08409ea","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6","VibList":[{"Name":"CP070930","Version":"GPK6.10-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8b239f426abd48ba8fe1fc6f2d","SupportedDevices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd-5.1.0-2197.8.sles16.x86_64.rpm","SHA1Sum":"0e44742ee35d5fe589c845793b62c37555d2821b","SHA256Sum":"4aed597a11a315e8738ad9138ba2bf05844cddb084fa789afa7379b4871f593d","SHA512Sum":"660e931fdd2d7984d32103b20a4ffc6c1d501344c46cdb185a10cd23adee74d9351c356fbae30b340e043ffe28072a42cfcb055fe20f98c79439aa1807fdcc76"}],"ComponentSizeInKB":11398,"CompsigList":["amsd-5.1.0-2197.8.sles16.x86_64.compsig"],"FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/2c","./usr/lib/.build-id/2c/4201ab35520fc89bb00bf09114c38294520b7d","./usr/lib/.build-id/3b","./usr/lib/.build-id/3b/49f3bf8a6619e58d59c7d5f625b091f07a74bf","./usr/lib/.build-id/44","./usr/lib/.build-id/44/c20d40d630b11afd35ffd29cd650fbd9f931e6","./usr/lib/.build-id/44/c20d40d630b11afd35ffd29cd650fbd9f931e6.1","./usr/lib/.build-id/61","./usr/lib/.build-id/61/b6e78204bdbb7f0088de92860a15ac5f3e6aba","./usr/lib/.build-id/88","./usr/lib/.build-id/88/17ede0c583b84c6d3df8b28f16427197fc3cd0","./usr/lib/.build-id/88/17ede0c583b84c6d3df8b28f16427197fc3cd0.1","./usr/lib/.build-id/9a","./usr/lib/.build-id/9a/e137946aa8bacbd8d9c182abc5646b0b14be73","./usr/lib/.build-id/9a/e137946aa8bacbd8d9c182abc5646b0b14be73.1","./usr/lib/.build-id/c0","./usr/lib/.build-id/c0/880948b88e815dbacb58c65624b292136e3f03","./usr/lib/.build-id/c0/880948b88e815dbacb58c65624b292136e3f03.1","./usr/lib/.build-id/e0","./usr/lib/.build-id/e0/b442cd5cc606699128816e516954d3519739aa","./usr/lib/.build-id/e0/b442cd5cc606699128816e516954d3519739aa.1","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/9a2272d0e157a735f577a4cc7b78a0bca7c1bd","./usr/lib/.build-id/fa/9a2272d0e157a735f577a4cc7b78a0bca7c1bd.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"Name":"amsd-5.1.0-2197.8.sles16.x86_64.rpm","SHA1Sum":"0e44742ee35d5fe589c845793b62c37555d2821b","SHA256Sum":"4aed597a11a315e8738ad9138ba2bf05844cddb084fa789afa7379b4871f593d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"5.1.0"}],"InstallationDependency":{},"Name":"Agentless Management Service (iLO5 and above) for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_378881ba42164b2c8f120d413c","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-103c-330615903307","a6b1a447-382a-5a4f-103c-330715903307","a6b1a447-382a-5a4f-103c-3307159004bd","a6b1a447-382a-5a4f-103c-3306159004bd"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U43","U41","U33","U44","A47","A48","U40","U47","U45","U24","U37","A46","U47","U38","U38","A45","U50","U46","I43","I45","I44","I42","A42","U54","U54","U54","U61","U60","U58","U58","U63","U63","A55","A55","A56","A56","U59","U58","U57","U65","U65","U62","A58","U69","U69","H11","I46","U68","U68","U68","U71","U66","U71","U72","U68","U72","U70","A59","U73","A66","A66","U74","U77","U71","U77","A72","U83"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002db","Version":"03.01.47.052"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f1590032e","Version":"03.01.47.052"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900381","Version":"03.01.47.052"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f159002dc","Version":"03.01.47.052"},{"DeviceName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900294","Version":"03.01.47.052"}]},"Files":[{"Checksum":[{"Filename":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.fwpkg","SHA1Sum":"61f9e902e64927e076e41efa09c01550021f370e","SHA256Sum":"6d0d657b5ed2ee88879790fcac7038f99b7b8ec6db709ce8d5782c4042e3cd2b","SHA512Sum":"356a9658dacc87b5fd661a967fac9ab8a567b5db286196194e4b8d391369549f295db0d1e434d9d6f4c829634f46b3a9f9dff1744ba778182ba5c94d82e52f69"}],"ComponentSizeInKB":12186,"CompsigList":[],"FileList":["HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.HPb","HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.xml","payload.json"],"Name":"HPE_SR416_SR932_Gen10P_Gen11_03.01.47.052_A.fwpkg","SHA1Sum":"61f9e902e64927e076e41efa09c01550021f370e","SHA256Sum":"6d0d657b5ed2ee88879790fcac7038f99b7b8ec6db709ce8d5782c4042e3cd2b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"TypeOfChange":"1","Version":"03.01.47.052"}],"InstallationDependency":{},"Name":"Firmware Package - HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"02DB1590","SWKeyExpectedPath":"firmware"},{"Name":"032E1590","SWKeyExpectedPath":"firmware"},{"Name":"03811590","SWKeyExpectedPath":"firmware"},{"Name":"02941590","SWKeyExpectedPath":"firmware"},{"Name":"02DC1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a2ae30555f9543a989b77716df","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U63","U54","U54","U54","U58","A56","A56","A55","A55","I45","U58","U63","U59","U46","U46","A43","A42","A43","U50","A42","U60","U57","U65","U65","U62","A59"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30505a575346","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30505a575348","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-30505a57534b","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1655SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-30505a584641","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"Samsung_PM165X_GPM1655SAMD4.fwpkg","SHA1Sum":"c29ac81ebe8e58e92c15654a2ad07d3de9c3690a","SHA256Sum":"583892a4172e615263221d2e5289328774780173b10f3da89b193a8718a71f08","SHA512Sum":"7519551fdf21cd670266d9d7aeaca4b87ab7ad60677aaa735ebf077b7abf4f3abef0661f039b051492257f6414b9de8583528a3f92d8a4bc13ac33d54651ccc1"}],"ComponentSizeInKB":1947,"CompsigList":[],"FileList":["payload.json","Samsung_PM165X_GPM1655SAMD4.HPb","Samsung_PM165X_GPM1655SAMD4.xml"],"Name":"Samsung_PM165X_GPM1655SAMD4.fwpkg","SHA1Sum":"c29ac81ebe8e58e92c15654a2ad07d3de9c3690a","SHA256Sum":"583892a4172e615263221d2e5289328774780173b10f3da89b193a8718a71f08","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-30505a575346","4d2340a5-304f-3130-3630-30505a575348","4d2340a5-304f-3330-3230-30505a57534b","4d2340a5-304f-3630-3430-30505a584641"],"TypeOfChange":"2","Version":"HPD4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600PZWSH, MO003200PZWSK, MO000800PZWSF and MO006400PZXFA","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800PZWSF","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001600PZWSH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003200PZWSK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO006400PZXFA","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1c3a30d0c9094371b5e3415413","SupportedDevices":["4d2340a5-304f-3130-3630-30505a575348","4d2340a5-304f-3330-3230-30505a57534b","4d2340a5-304f-3030-3830-30505a575346","4d2340a5-304f-3630-3430-30505a584641"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"cp068666.exe","SHA1Sum":"d5add7de0b103d6b9f09017eb55b228239259c5f","SHA256Sum":"c48cad8ebb9094ae595c5a4a9139daa1923e2413bc9e73f4bfeb25c2679e2368","SHA512Sum":"ce0ad2b667ffacced251939c370dc2bfab3a30986827498b6dbdb1275ef886283c1b4a4cb3a7d20fe0d2e6e3d5a49060c5301480d129d1da34d90fb6b33690b5"}],"ComponentSizeInKB":4017,"CompsigList":["cp068666.compsig"],"FileList":["cp068666.xml","cpqsetup.exe","K401HPG5.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068666.exe","SHA1Sum":"d5add7de0b103d6b9f09017eb55b228239259c5f","SHA256Sum":"c48cad8ebb9094ae595c5a4a9139daa1923e2413bc9e73f4bfeb25c2679e2368","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4949af45d6614c159f064c1c94","SupportedDevices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U40_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073169.exe","SHA1Sum":"24856b900a1ebefa2684a2c0e55b46b29bab9c84","SHA256Sum":"5b4f87d1358cc2e2e88e6de56e21194d7e72b5e3909143daa858ff567f99a828","SHA512Sum":"4e3523070a88c5c39013ec274abaf04aeeca06a84f37520a078e7bbe8e718b94b5bf6869a510e7ba0080dbabf3e0d154a0c5951f15d95d24ef50d247c036b530"}],"ComponentSizeInKB":11437,"CompsigList":["cp073169.compsig"],"FileList":["cp073169.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U40_3.70_08_19_2026.signed.flash"],"Name":"cp073169.exe","SHA1Sum":"24856b900a1ebefa2684a2c0e55b46b29bab9c84","SHA256Sum":"5b4f87d1358cc2e2e88e6de56e21194d7e72b5e3909143daa858ff567f99a828","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_35d1e0f265554bf7bdd3d0c555","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U40","U40"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KXG50PNV2T04","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AFGA4103.sig","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AFGA4103"}]},"Files":[{"Checksum":[{"Filename":"cp070412.exe","SHA1Sum":"9bfe38acc9f10b109968e48dc066227b3ae59624","SHA256Sum":"ba48d54cad492cd5ccfa2e95216da56b0d6e74ad7f07e326351919cb4c82c2f2","SHA512Sum":"5739fe46dd42bb651f252fe43ddbbd4b72ed160b5a2af8f318b8a1331fcaeae8ec576aecbe5517b1eed203e5ed45dfa68b3872bf64acc423ea335090d4aff940"}],"ComponentSizeInKB":7468,"CompsigList":["cp070412.compsig"],"FileList":["AFGA4103.sig","cp070412.xml","cpqsetup.exe","ilorest_chif.dll","payload.json"],"Name":"cp070412.exe","SHA1Sum":"9bfe38acc9f10b109968e48dc066227b3ae59624","SHA256Sum":"ba48d54cad492cd5ccfa2e95216da56b0d6e74ad7f07e326351919cb4c82c2f2","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"AFGA4103"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Microsoft Windows - KXG50PNV2T04 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"KXG50PNV2T04","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ac220d665e8c416882baad1fef","SupportedDevices":["002340a5-584b-3547-3050-4e5632543034"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["11.0","10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H09","H10","H10","H10","H08","H08"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG4"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG4"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG4"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG4"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG4"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9e87eecb3f_0HPG4-1.1_amd64.deb","SHA1Sum":"55f7131d60767dcff89f26d313b50f7aeb1cfa8b","SHA256Sum":"0a23fa7a8deb5eb39611ff48c6e9d8533eec5e1d4bfd6b4a6f161ec0ee133f21","SHA512Sum":"de4505e3abf844eee80d8e09621cad9ed0322abf043fb6991bc158e95c353455c79149c86b9bef3db4475c715011968386ed60760b8e3bedfe3a9b46ec13fb60"}],"ComponentSizeInKB":3578,"CompsigList":["firmware-hdd-9e87eecb3f_0HPG4-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/CP072236.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/M52002TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072236.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072236.scexe"],"Name":"firmware-hdd-9e87eecb3f_0HPG4-1.1_amd64.deb","SHA1Sum":"55f7131d60767dcff89f26d313b50f7aeb1cfa8b","SHA256Sum":"0a23fa7a8deb5eb39611ff48c6e9d8533eec5e1d4bfd6b4a6f161ec0ee133f21","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWSXF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWSXH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWSXK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWUGF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWUGH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWUGK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f1dc40e25bb748459312d9e04e","SupportedDevices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-41cdb1c9da_0HPG3-2.1_amd64.deb","SHA1Sum":"7f37fae1bde5db0ab759380e97854e0f52b746fb","SHA256Sum":"06a26327322d19c744fa62bea99f47d52c2573088272934e95cc43115b26155f","SHA512Sum":"c8fcb74693ea3e2f3c3ff4da47800d92a36dfcc53e07cac4fcc287094b30648097f17a18411d8eb5f22db7f4efb61738f578d296ea5c495e8a8a69a12ca432f0"}],"ComponentSizeInKB":4746,"CompsigList":["firmware-hdd-41cdb1c9da_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/CP071736.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/WLEBsssATFG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071736.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071736.scexe"],"Name":"firmware-hdd-41cdb1c9da_0HPG3-2.1_amd64.deb","SHA1Sum":"7f37fae1bde5db0ab759380e97854e0f52b746fb","SHA256Sum":"06a26327322d19c744fa62bea99f47d52c2573088272934e95cc43115b26155f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000GWUDA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b9559ba9ab684ea891b0313d5e","SupportedDevices":["4d2340a5-3042-3431-3030-304757554441"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070964.zip","SHA1Sum":"22dbd9ae22256355e0905555b661ad6d586c1b67","SHA256Sum":"160160b8cfcb18becd032b90e717de391a2365c1c3e84d69de35b1178ed712c9","SHA512Sum":"80f0fbdf785adad5d84731f93725c437e0e7b0d838d7cca26c08b7b1202f112054484fa74f7be6e42d871abdf3dc0ffe7d0cd42a0c5f0d51db5a7d843bd4b17c"}],"ComponentSizeInKB":20359,"CompsigList":["CP070964.compsig"],"FileList":["/CP070964_BUILD_1.data","/CP070964.vmexe64","/CP070964.vmfile","/CP070964_VMw.zip","/CP070964.xml","/payload.json","/CP070964_VMw.zip/index.xml","/CP070964_VMw.zip/vendor-index.xml","/CP070964_VMw.zip/metadata.zip","/CP070964_VMw.zip/vib20/CP070964/HPE_bootbank_CP070964_HPD4.1-8.0.0.20613240.vib","/CP070964_VMw.zip/metadata.zip/vendor-index.xml","/CP070964_VMw.zip/metadata.zip/vmware.xml","/CP070964_VMw.zip/metadata.zip/vibs/CP070964-1531350772482773952.xml","/CP070964_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070964_HPD4.1-8.0.0.20613240.xml"],"Name":"CP070964.zip","SHA1Sum":"22dbd9ae22256355e0905555b661ad6d586c1b67","SHA256Sum":"160160b8cfcb18becd032b90e717de391a2365c1c3e84d69de35b1178ed712c9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070964","Version":"HPD4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JWUDB Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8bea007ef1da4844977d8351bf","SupportedDevices":["4d2340a5-3042-3431-3030-304a57554442"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.4706"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1.x86_64.rpm","SHA1Sum":"10429e62caec45e566bbe7b1cdbb6b93493b46ce","SHA256Sum":"f03a2e26a947031d4224376f1f315801c1489e25de531925d1faccf612f775cf","SHA512Sum":"d16335d02f5b254fada22fb835bc3ef1044f3a04e72ba227b7cbbea37468a4e89d0a96a1d42a7c707d7d6faac11a61065ae12da4f8a0f4b13acc02430d199cf2"}],"ComponentSizeInKB":7714,"CompsigList":["firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/CP072408.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/fw-ConnectX4-rel-12_28_4706-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072408.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072408.scexe"],"Name":"firmware-nic-mellanox-ib-cx4-cx5-1.0.18-1.1.x86_64.rpm","SHA1Sum":"10429e62caec45e566bbe7b1cdbb6b93493b46ce","SHA256Sum":"f03a2e26a947031d4224376f1f315801c1489e25de531925d1faccf612f775cf","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"TypeOfChange":"1","Version":"1.0.18"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Linux x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_IB_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b073bab29f3c444793dc894ba0","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000ef","a6b1a447-382a-5a4f-15b3-101715900257","a6b1a447-382a-5a4f-15b3-101715900255"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","16.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A47","A48","U50","U47","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U19","U46","HPE Apollo 2000 Gen10 Plus System","U61","A41","U37","A42","U56","U27","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-5dcf26fa42_0HPD3-2.1_amd64.deb","SHA1Sum":"2ee3d4363bb1f09e0a73ec5acccc71ff9e7a6203","SHA256Sum":"5d4c4ea53ab1c977246d552a3af8d59a7c60ef184ece52be03cdf29430f2e9d8","SHA512Sum":"9ee840fe3baa7ad36a51041944e3da8d3eff7487a8b65b794da6e66cf45215b57d0314f439f148e08a0cb3caa351fc209487eb129bc22c3361bf47754c83c01f"}],"ComponentSizeInKB":4332,"CompsigList":["firmware-hdd-5dcf26fa42_0HPD3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/BCHPC17M.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/CP071708.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071708.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071708.scexe"],"Name":"firmware-hdd-5dcf26fa42_0HPD3-2.1_amd64.deb","SHA1Sum":"2ee3d4363bb1f09e0a73ec5acccc71ff9e7a6203","SHA256Sum":"5d4c4ea53ab1c977246d552a3af8d59a7c60ef184ece52be03cdf29430f2e9d8","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_51fb335eb60a46d2a486c067d3","SupportedDevices":["452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42","452340a5-304f-3030-3430-304a57444b50","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3830-304a57444b56"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR216i-p_Gen10P_52.38.3-6909_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.38.3-6909"}]},"Files":[{"Checksum":[{"Filename":"HPE_MR216i-p_Gen10P_52.38.3-6909_A.fwpkg","SHA1Sum":"6d032f8806bac7e7016620fe3cef26ccda84bbcd","SHA256Sum":"d5fac6f4608b8e4260d28b667f1b1c5e6b24e8ed6cb893752f49d7d770aa29af","SHA512Sum":"240ff92aba48204f42f59b83cb35ff21caea78ef5ac96ba6f7081daa8ef860e3a7dd11db0f33e66aafff604d3859c2895413b1f470fb31f27239e370dd4d74bc"}],"ComponentSizeInKB":7347,"CompsigList":[],"FileList":["HPE_MR216i-p_Gen10P_52.38.3-6909_A.HPb","HPE_MR216i-p_Gen10P_52.38.3-6909_A.xml","payload.json"],"Name":"HPE_MR216i-p_Gen10P_52.38.3-6909_A.fwpkg","SHA1Sum":"6d032f8806bac7e7016620fe3cef26ccda84bbcd","SHA256Sum":"d5fac6f4608b8e4260d28b667f1b1c5e6b24e8ed6cb893752f49d7d770aa29af","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032b"],"TypeOfChange":"1","Version":"52.38.3-6909"}],"InstallationDependency":{},"MinimumActiveVersion":"52.26.3.5487","Name":"Firmware Package - HPE MR216i-p Gen10 Plus Tri Mode Controller","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"032B1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7d47d1747a545578bada4ab3c","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","A43","A43","A42","U60","U46","U61","A59","U84","A72","U64","U48"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072376.zip","SHA1Sum":"2cc7404006156fa696e17c45971f30029451042c","SHA256Sum":"686c9d61876413b090308797d55be44fe774d6b0f83238d98017917df909e9e3","SHA512Sum":"ca588be7a70537f98301671b14e8564b1e85977fb31dd4effcb4f836f2f7fb973b0ce1dec3a68974bc6bd9c21ea780673a35817029ca7d6925ec29d8253fc97e"}],"ComponentSizeInKB":24219,"CompsigList":["CP072376.compsig"],"FileList":["/CP072376.xml","/CP072376_VMw.zip","/payload.json","/CP072376.vmexe64","/CP072376.vmfile","/CP072376_VMw.zip/index.xml","/CP072376_VMw.zip/vendor-index.xml","/CP072376_VMw.zip/metadata.zip","/CP072376_VMw.zip/vib20/CP072376/HPE_bootbank_CP072376_1.0.2-1OEM.900.0.24755229.vib","/CP072376_VMw.zip/metadata.zip/vendor-index.xml","/CP072376_VMw.zip/metadata.zip/vmware.xml","/CP072376_VMw.zip/metadata.zip/vibs/CP072376-5588480391762199828.xml","/CP072376_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072376_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP072376.zip","SHA1Sum":"2cc7404006156fa696e17c45971f30029451042c","SHA256Sum":"686c9d61876413b090308797d55be44fe774d6b0f83238d98017917df909e9e3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP072376","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for Mellanox Open Ethernet cards","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aa3a6dd076ab43cea31d53e061","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070111.zip","SHA1Sum":"0da5e855d317f44d47e6b35a9895df0a27ea264a","SHA256Sum":"dae543bd7a32f8c15730d28f827899b5541208f49a5e574f760307b0484acab8","SHA512Sum":"6f9c3aef903d691e1c40c161f6b09ebb712e72db2e8cb8d21736e77983811002087647bde5ccbae4454a4aad6116ba168caa8b93bca6322da41b8ca0acd55dcd"}],"ComponentSizeInKB":5695,"CompsigList":["cp070111.compsig"],"FileList":["/cp070111.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedf/QLC_bootbank_qedf_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedi/QLC_bootbank_qedi_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedf-686432869232018140.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedi-5880836182664745913.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedentv-6528860809003751673.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedrntv-4334621844710657275.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.xml"],"Name":"cp070111.zip","SHA1Sum":"0da5e855d317f44d47e6b35a9895df0a27ea264a","SHA256Sum":"dae543bd7a32f8c15730d28f827899b5541208f49a5e574f760307b0484acab8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"qedi","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.90.2-1OEM.800.1.0.20613240"},{"Name":"qedf","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.90.2-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.420.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedi:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedf:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ba94294b8f824b7997263118f9","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","U46","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-305958554a42","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-305958554a43","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-305958554a44","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-305958554855","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-305958554856","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALFHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-305958554a41","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_CM7_KACM7ALFHPK4.fwpkg","SHA1Sum":"9214dd9e0e54a062fd7748d07e1d71b056e47554","SHA256Sum":"5a40fd4dc0a7c09d71013355d6c5ead183b9a9a0d22710e9c8c15f13401d0701","SHA512Sum":"4ded682fe74ec3f52a7130b2f37060d61c36957391a85b35106e37eb7e84fbfbeaf45aaf13f8f772bdc1345117d24d541c8fe5274a3d776fce660daae59a7c77"}],"ComponentSizeInKB":2458,"CompsigList":[],"FileList":["Kioxia_CM7_KACM7ALFHPK4.HPb","Kioxia_CM7_KACM7ALFHPK4.xml","payload.json"],"Name":"Kioxia_CM7_KACM7ALFHPK4.fwpkg","SHA1Sum":"9214dd9e0e54a062fd7748d07e1d71b056e47554","SHA256Sum":"5a40fd4dc0a7c09d71013355d6c5ead183b9a9a0d22710e9c8c15f13401d0701","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-305958554a42","4d2340a5-304f-3330-3230-305958554a43","4d2340a5-304f-3630-3430-305958554a44","562340a5-304f-3130-3932-305958554855","562340a5-304f-3330-3834-305958554856","562340a5-304f-3730-3638-305958554a41"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600YXUJB, MO003200YXUJC, MO006400YXUJD, VO001920YXUHU, VO003840YXUHV and VO007680YXUJA","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600YXUJB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200YXUJC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400YXUJD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920YXUHU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840YXUHV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680YXUJA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_518ac76b543d46469d9245292e","SupportedDevices":["4d2340a5-304f-3130-3630-305958554a42","4d2340a5-304f-3330-3230-305958554a43","4d2340a5-304f-3630-3430-305958554a44","562340a5-304f-3130-3932-305958554855","562340a5-304f-3330-3834-305958554856","562340a5-304f-3730-3638-305958554a41"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"cp072399.exe","SHA1Sum":"0c5c7945d2ca5eefb6f1808ba07cc0e9723003be","SHA256Sum":"e31a7e7ffb513d4a8c48cff373f0b7446f50db2e7cdc9224456eba73f040011a","SHA512Sum":"d456e192f0530c3e41b65bfa36ceddffc2718376bf76d0636194e60d3bf8526b95f77e9d78a9f5dd38377d84a3ef5d55b57146a90bcc45aeaa9918a75f6a8b95"}],"ComponentSizeInKB":29063,"CompsigList":["cp072399.compsig"],"FileList":["cp072399.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072399.exe","SHA1Sum":"0c5c7945d2ca5eefb6f1808ba07cc0e9723003be","SHA256Sum":"e31a7e7ffb513d4a8c48cff373f0b7446f50db2e7cdc9224456eba73f040011a","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.0.19"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Windows x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2b43009362174268b7b46d88e9","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","U31","U31","U41","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"SSDPEL1K375GA","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"E2010603.bin","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"E2010603"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1.x86_64.rpm","SHA1Sum":"d7c842815b6666c2eec2f0adeafe435f4fc918de","SHA256Sum":"d4b57fa432793af357c31ad29889afda5cf4c7d10543d175327f62f65ea7b8f9","SHA512Sum":"6e57219ee9aa26ff85c283eb6d7ba7adb6303aefc946e1935dd43a88eff6b371430305c1411d9dbc36563da26f4e4428d060ad77cf4cbdd2dee9c1ef0a110264"}],"ComponentSizeInKB":24470,"CompsigList":["firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/CP060386.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/intelmas","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/intelmas/intelmas.zip","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP060386.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP060386.scexe"],"Name":"firmware-hdd-intel-optane-pel1k375ga-E2010603-1.1.x86_64.rpm","SHA1Sum":"d7c842815b6666c2eec2f0adeafe435f4fc918de","SHA256Sum":"d4b57fa432793af357c31ad29889afda5cf4c7d10543d175327f62f65ea7b8f9","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"E2010603"}],"InstallationDependency":{},"Name":"Online Intel Optane SSD Flash Component for Linux - SSDPEL1K375GA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"SSDPEL1K375GA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f457b16828314c279f84d52e24","SupportedDevices":["532340a5-4453-4550-4c31-4b3337354741"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","7.0","9.0","22.04","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.76 (05/28/2026)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"U48_3.76_05_28_2026.fwpkg","SHA1Sum":"ce7f5d2c99b363c6ec35c8d99507518022ca43fb","SHA256Sum":"71e12c75f53a99e21a04ace89bb7d06c98536e4a7c0c1ab8c9668894b70d9e0b","SHA512Sum":"345f5c8def4d9fecec9d1e1de53f54bf5593e1d087d0bfc973bcade34f911a9ee67f029dab1d46960036f1320a97471c4629084b922032153244d04714ca2635"}],"ComponentSizeInKB":16424,"CompsigList":[],"FileList":["payload.json","U48_3.76_05_28_2026.signed.flash","U48_3.76_05_28_2026.xml"],"Name":"U48_3.76_05_28_2026.fwpkg","SHA1Sum":"ce7f5d2c99b363c6ec35c8d99507518022ca43fb","SHA256Sum":"71e12c75f53a99e21a04ace89bb7d06c98536e4a7c0c1ab8c9668894b70d9e0b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus (U48) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd4d9e203f8d4cffad82241bc2","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U48"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Operating System - Enhancements","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069670.exe","SHA1Sum":"1850c83f4a988cc95ff1168f24af16043035efa8","SHA256Sum":"00289058e393cff1285e7033f8ce278d50b2159af05be72e4f542de5455aa620","SHA512Sum":"e8363039b653485b97b7b233cef7c3f68dba83c9d82394439c45bc915bf01be5666cdd6617ea820fc7f13cb30e8dd023f738d295dbe9c8a65e71abcb0c9c0f9e"}],"ComponentSizeInKB":616,"CompsigList":["cp069670.compsig"],"FileList":["cp069670.xml","cpqsetup.exe","installer.dll","non-pnp/","non-pnp/amdpshed.cat","non-pnp/amdpshed.inf","non-pnp/amdpshed.sys"],"Name":"cp069670.exe","SHA1Sum":"1850c83f4a988cc95ff1168f24af16043035efa8","SHA256Sum":"00289058e393cff1285e7033f8ce278d50b2159af05be72e4f542de5455aa620","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca8078e42"],"TypeOfChange":"1","Version":"1.0.0.51"}],"InstallationDependency":{},"Name":"AMD PSHED Plug-in service for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"amdpshed.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9001e38f8173493b9fb7ad5c3a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":true,"SupportedProducts":["A55","A56","A55","A56","A42","A42","A40","A42","A43","A43","A43","A41","A47","A48","A46","HPE Cray XD295v"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SPSGen10_04.01.05.312.signed.bin","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.312"}]},"Files":[{"Checksum":[{"Filename":"SPSGen10_04.01.05.312.fwpkg","SHA1Sum":"1eadead737ed89c3af3ad53aa6b1f02bee99f40f","SHA256Sum":"a5e6d0bc072cc158384229a0cf85f42841caf1f1795b5feecbfe876b93e6fbd0","SHA512Sum":"94d98c89aac77a64479ffacbc29b351d433ca8954b9056814e860ce40b67c22670fcd15a9ed77d656202ed374706a08470bba6d62bf5ec1773b7c1933bcd86a2"}],"ComponentSizeInKB":8217,"CompsigList":[],"FileList":["payload.json","SPSGen10_04.01.05.312.signed.bin","SPSGen10_04.01.05.312.xml"],"Name":"SPSGen10_04.01.05.312.fwpkg","SHA1Sum":"1eadead737ed89c3af3ad53aa6b1f02bee99f40f","SHA256Sum":"a5e6d0bc072cc158384229a0cf85f42841caf1f1795b5feecbfe876b93e6fbd0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.312"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE Gen10 Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2b7345e3c7fc4c24803bc2dc1b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U41","U33","U40","U39","U45","U37","U38","U38","U39","H08","H08","I43","I42"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"cp068732.exe","SHA1Sum":"14a4746062f03892b84c4878b54e427eafb748f8","SHA256Sum":"bb6a32ec52e008529f825ef04711a2ab21eed48b735fbd7a6ad503c5314c7aef","SHA512Sum":"dee0482413e1ab4f577167950bdb7e6d5b55ca46fb5cf31f44064fd924cb4c95beee342e2a2d64500704a4546acaf279f7e9779607c2d121c9b207db01ee0899"}],"ComponentSizeInKB":4098,"CompsigList":["cp068732.compsig"],"FileList":["cp068732.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNNSD8.rel","setup.dll"],"Name":"cp068732.exe","SHA1Sum":"14a4746062f03892b84c4878b54e427eafb748f8","SHA256Sum":"bb6a32ec52e008529f825ef04711a2ab21eed48b735fbd7a6ad503c5314c7aef","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWWQB and MB002000JWWQA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5d391774ceff44a2a6b208614f","SupportedDevices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"3653aa90-7089-453a-899c-792827a50d67","Devices":{"Device":[{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000049535320","Version":"1.24"},{"DeviceName":"NVMe Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ISS_NVMe_BP_PIC_flashV1B24_signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00004e564d65","Version":"1.24"}]},"Files":[{"Checksum":[{"Filename":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","SHA1Sum":"633b896a37fa45ad5cd071ecf6e21a400012eee5","SHA256Sum":"78af2e9576979b534a8e4482664905540d6f2edd76f71f1afb123372a789d402","SHA512Sum":"6afe5f6af017b457e9b1998f3b3dc2320d64fd717d7bb6547fd513ec1f0c604ff489f24eeb1c6efdaa66076a64c4e045cbd12a614099d943c1890e7ec12850cb"}],"ComponentSizeInKB":37,"CompsigList":[],"FileList":["ISS_NVMe_BP_PIC_flashV1B24.xml","ISS_NVMe_BP_PIC_flashV1B24_signed.hex","payload.json"],"Name":"ISS_NVMe_BP_PIC_flashV1B24.fwpkg","SHA1Sum":"633b896a37fa45ad5cd071ecf6e21a400012eee5","SHA256Sum":"78af2e9576979b534a8e4482664905540d6f2edd76f71f1afb123372a789d402","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000049535320","00000000-0000-0000-0000-00004e564d65"],"TypeOfChange":"1","Version":"1.24"}],"InstallationDependency":{},"Name":"Firmware Package - Gen10 NVMe Backplane PIC Firmware","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"NVMePIC-Gen10","SWKeyExpectedPath":"firmware:nvmebackplane"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd4644ff6898456b8bf5d3a92e","SupportedDevices":["00000000-0000-0000-0000-00004e564d65"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","U36","U41","U40","U45","U37","U38","U38","I43","I42","A43"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070922.zip","SHA1Sum":"f58facdd9a2de598a33895b4c487d513e8cf63e5","SHA256Sum":"4513fefedba1b162edcdebb23968b4deb14039f20fde78b76d8fd80d50ca46b3","SHA512Sum":"5dca17389cfac8099fa4229e64ab642068a0f22e73bc69a5b3b270de11f4317a62255a073ea9bf1a59d93cbd86b1fa4f7c705b4d4f1734b9883b582a2882d021"}],"ComponentSizeInKB":20944,"CompsigList":["CP070922.compsig"],"FileList":["/CP070922_BUILD_7.data","/CP070922.vmexe64","/CP070922.vmfile","/CP070922_VMw.zip","/CP070922.xml","/payload.json","/CP070922_VMw.zip/index.xml","/CP070922_VMw.zip/vendor-index.xml","/CP070922_VMw.zip/metadata.zip","/CP070922_VMw.zip/vib20/CP070922/HPE_bootbank_CP070922_HPG1.7-8.0.0.20613240.vib","/CP070922_VMw.zip/metadata.zip/vendor-index.xml","/CP070922_VMw.zip/metadata.zip/vmware.xml","/CP070922_VMw.zip/metadata.zip/vibs/CP070922-8853817900184222612.xml","/CP070922_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070922_HPG1.7-8.0.0.20613240.xml"],"Name":"CP070922.zip","SHA1Sum":"f58facdd9a2de598a33895b4c487d513e8cf63e5","SHA256Sum":"4513fefedba1b162edcdebb23968b4deb14039f20fde78b76d8fd80d50ca46b3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070922","Version":"HPG1.7-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives.","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8030605e03cb42dfbd8c04f471","SupportedDevices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp068738.exe","SHA1Sum":"1b9e4ef5501f65f52d33cc3376e9d2e874304bbc","SHA256Sum":"30b46d016872244b191c192e397b9525ed6969054abbf8faece08d074cab1c2d","SHA512Sum":"fbe006eb46acdf7bc06ca1cab553e80523ee5440ab34daee2ab6b5a6048e0c541c4ead492a33fa6a3845fe4eb939201135d458b47d0a07654c528c2600ecb39c"}],"ComponentSizeInKB":4254,"CompsigList":["cp068738.compsig"],"FileList":["cp068738.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVSBPSD6.rel"],"Name":"cp068738.exe","SHA1Sum":"1b9e4ef5501f65f52d33cc3376e9d2e874304bbc","SHA256Sum":"30b46d016872244b191c192e397b9525ed6969054abbf8faece08d074cab1c2d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bb3daea065d04dc191baa120bf","SupportedDevices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068750.exe","SHA1Sum":"cb2a334b3392f6bd6b292515073997ed671f96bc","SHA256Sum":"b0bf3e8493ec71a5447a25d723fe4e04a666eef512bd788a029018b32e7c1746","SHA512Sum":"d1e82e5a81ddf7759c17a6a15255c130a5a4c3e3227facba8c2f93862e58d3a697a942913f22dd0dd4b9e234d2f295a1c9450158f95860ed4e3f88eabc53b209"}],"ComponentSizeInKB":5212,"CompsigList":["cp068750.compsig"],"FileList":["cp068750.xml","cpqsetup.exe","mnv_cli.exe","payload.json","PCHFA2BP.rel","setup.dll"],"Name":"cp068750.exe","SHA1Sum":"cb2a334b3392f6bd6b292515073997ed671f96bc","SHA256Sum":"b0bf3e8493ec71a5447a25d723fe4e04a666eef512bd788a029018b32e7c1746","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JXUCC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_20c192b14fdb4fb3a6a567aa63","SupportedDevices":["4d2340a5-3042-3431-3030-304a58554343"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071214.exe","SHA1Sum":"3085b3ffc2de5e03ab2fd8d0f68ce5395505310f","SHA256Sum":"d03f91276b40cb2d8566f3709869f7d31069e028afa1448846009ce144cf6ed2","SHA512Sum":"201f5a272fd7cb44b966868ba9787fe21d235d6da5373506f9732f15933e8639c9f19a886a4ac0ad03d7ce71301c27cd111f41c9e44dadcdabe561ed9c213b48"}],"ComponentSizeInKB":4210,"CompsigList":["cp071214.compsig"],"FileList":["cp071214.xml","cpqsetup.exe","elxdrvr-fc-14.4.624.0-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"Name":"cp071214.exe","SHA1Sum":"3085b3ffc2de5e03ab2fd8d0f68ce5395505310f","SHA256Sum":"d03f91276b40cb2d8566f3709869f7d31069e028afa1448846009ce144cf6ed2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.624.0"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ade8aa407a294fdfa0a7aa3e05","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U60_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.70 (08/20/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u60-2.70_2026_08_20-1.1.x86_64.rpm","SHA1Sum":"e42185519ad911575deebaf8cd2c315c9258d0e4","SHA256Sum":"79df496d8aeb23ab7e62942f11f4b7c50a2c0087e7813dc335369c5e3d3679a9","SHA512Sum":"06ac90c1222f14315a54fdebf2cbefaa0da83fc3b8bccbc53eb64e923bdb683dab56d5020fe783d98281ca9a8882a5db2969951535ce839d095f4e5e7ef0279c"}],"ComponentSizeInKB":16776,"CompsigList":["firmware-system-u60-2.70_2026_08_20-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.70_2026_08_20-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.70_2026_08_20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.70_2026_08_20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.70_2026_08_20-1.1/CP073280.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.70_2026_08_20-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.70_2026_08_20-1.1/U60_2.70_08_20_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.70_2026_08_20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.70_2026_08_20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u60-2.70_2026_08_20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073280.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073280.scexe"],"Name":"firmware-system-u60-2.70_2026_08_20-1.1.x86_64.rpm","SHA1Sum":"e42185519ad911575deebaf8cd2c315c9258d0e4","SHA256Sum":"79df496d8aeb23ab7e62942f11f4b7c50a2c0087e7813dc335369c5e3d3679a9","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.70_08-20-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Proliant DL20 Gen10 Plus Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_df61de2ea1f24760b47fae510f","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-smartpqi-2.1.40-020.rhel10u0.x86_64.rpm","SHA1Sum":"322c3162f95b8f23e5cc5f517fd8c1d715d90a38","SHA256Sum":"9cfefe6ec509602a3db61125d3d49360ef59d2e3d6db4385b7a5e661e12a841a","SHA512Sum":"aa3de9e0a0fdfa6dcde8c540922623007a83b02bf0cdbd723dbb6a2c844ed6c73477a2b5104b34ba2cdad33569ae9cc636725fb74d3c9773a0137e70b4ef3bee"}],"ComponentSizeInKB":114,"CompsigList":["kmod-smartpqi-2.1.40-020.rhel10u0.x86_64.compsig"],"FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.12.0-55.9.1.el10_0.x86_64","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/smartpqi","./lib/modules/6.12.0-55.9.1.el10_0.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/f7","./usr/lib/.build-id/f7/224b178390684ba55b948b52b191f226e31983","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"Name":"kmod-smartpqi-2.1.40-020.rhel10u0.x86_64.rpm","SHA1Sum":"322c3162f95b8f23e5cc5f517fd8c1d715d90a38","SHA256Sum":"9cfefe6ec509602a3db61125d3d49360ef59d2e3d6db4385b7a5e661e12a841a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.40-020"},{"Checksum":[{"Filename":"kmod-smartpqi-2.1.40-020.rhel10u1.x86_64.rpm","SHA1Sum":"bf45cd1885afa9aca388e5166428926af40c4dd2","SHA256Sum":"f33eaba79a855417d483f5e271cca76f1ffb26ade01f1e8fba4799992a9cb42b","SHA512Sum":"3b8109297fdc68f610e975fe1cb4d10d3b9cb6145dd6b38f1888434b3418192affc06a875279d1bce56c0e2bcc3911f3fbfe1267f23bf5d848ae51b909a1f79a"}],"ComponentSizeInKB":113,"CompsigList":["kmod-smartpqi-2.1.40-020.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/smartpqi","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/72","./usr/lib/.build-id/72/35b83af3187dfd926218b08de0de4926a4bb8a","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"Name":"kmod-smartpqi-2.1.40-020.rhel10u1.x86_64.rpm","SHA1Sum":"bf45cd1885afa9aca388e5166428926af40c4dd2","SHA256Sum":"f33eaba79a855417d483f5e271cca76f1ffb26ade01f1e8fba4799992a9cb42b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.40-020"}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 10 (64-bit)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3806afac3ba849ffa40bccc9bf","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","A43","HPE Apollo 2000 Gen10 Plus System","A42","U46","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","A43","I44","U60","U61","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","U71","U68","U68","U72","U68","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP56 MCX623106AS-CDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"22_49_1014-MCX623106AS-CDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30042","Version":"22.49.1014"}]},"Files":[{"Checksum":[{"Filename":"22_49_1014-MCX623106AS-CDA_Ax.pldm.fwpkg","SHA1Sum":"8bb486d6897fe0310e159b78557738da5b13befa","SHA256Sum":"6d003bd488b943a7ddda145f8067dca3bd7cd56575a1dad1e989343bc6110cb4","SHA512Sum":"5fce88b57c19c2c3dc69e5ddd02baed7e2441666847063c93b4f306284b63afbc68e5e765d8cf51e664ff3b87898a5a055e3fee025de318da7a77f9b103f4e0c"}],"ComponentSizeInKB":7741,"CompsigList":[],"FileList":["22_49_1014-MCX623106AS-CDA_Ax.pldm.signed","22_49_1014-MCX623106AS-CDA_Ax.pldm.xml","payload.json"],"Name":"22_49_1014-MCX623106AS-CDA_Ax.pldm.fwpkg","SHA1Sum":"8bb486d6897fe0310e159b78557738da5b13befa","SHA256Sum":"6d003bd488b943a7ddda145f8067dca3bd7cd56575a1dad1e989343bc6110cb4","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"TypeOfChange":"1","Version":"22.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX623106AS-CDAT Ethernet 100Gb 2-port QSFP56 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623106AS-CDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6d1c79437e2b47fc8dde5ee7a6","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101d15b30042"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U58","U58","H10","H10","U62","U63","U57","A55","A55","A56","A56","U59","U58","U69","U69","U72","U70","U68","U68","U66","A59","A66","A66","U72","U77","A72"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c7df7ceedb-HPD9-2.1.x86_64.rpm","SHA1Sum":"57ae2f4e61510c35a5bc5449cd3e6d6145ddaf21","SHA256Sum":"4fcce98b217a4fe670dace26c0a10e111d9d617ff802995cb54bd1a529075ec8","SHA512Sum":"a85f41712c23b0be003aa2a892330f3da0932075bd1c9023beb60c4aa64277cbbf83a11674d35c9be855aab5f75709a5659e553547c421bdd6356d1db4152c8c"}],"ComponentSizeInKB":5009,"CompsigList":["firmware-hdd-c7df7ceedb-HPD9-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/CP068859.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/TA14SXe0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068859.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068859.scexe"],"Name":"firmware-hdd-c7df7ceedb-HPD9-2.1.x86_64.rpm","SHA1Sum":"57ae2f4e61510c35a5bc5449cd3e6d6145ddaf21","SHA256Sum":"4fcce98b217a4fe670dace26c0a10e111d9d617ff802995cb54bd1a529075ec8","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1d6229f8dc1e47bdbf9d5dbc3f","SupportedDevices":["452340a5-3048-3030-3630-304a57485048","452340a5-3048-3030-3930-304a5748504b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"CP070946.zip","SHA1Sum":"9e47b9195758aa2c8a0eaeb4ce4f9b8eb1eb2e34","SHA256Sum":"d86676117d4e00609e7cc9c14077d016dd541417ba9d9f47318d99f49afc6d75","SHA512Sum":"1a4e9022f5b00d64a724d6ccba654c97a36229a4db0e6a943dc3f2e945605f109c9fd06884e62d80b76b3caf5676b583acef37117529e0b232fec5d82ed1aab5"}],"ComponentSizeInKB":19508,"CompsigList":["CP070946.compsig"],"FileList":["/CP070946_BUILD_4.data","/CP070946.vmexe64","/CP070946.vmfile","/CP070946_VMw.zip","/CP070946.xml","/payload.json","/CP070946_VMw.zip/index.xml","/CP070946_VMw.zip/vendor-index.xml","/CP070946_VMw.zip/metadata.zip","/CP070946_VMw.zip/vib20/CP070946/HPE_bootbank_CP070946_HPD8.4-8.0.0.20613240.vib","/CP070946_VMw.zip/metadata.zip/vendor-index.xml","/CP070946_VMw.zip/metadata.zip/vmware.xml","/CP070946_VMw.zip/metadata.zip/vibs/CP070946--2975616020979096983.xml","/CP070946_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070946_HPD8.4-8.0.0.20613240.xml"],"Name":"CP070946.zip","SHA1Sum":"9e47b9195758aa2c8a0eaeb4ce4f9b8eb1eb2e34","SHA256Sum":"d86676117d4e00609e7cc9c14077d016dd541417ba9d9f47318d99f49afc6d75","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP070946","Version":"HPD8.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000JWWQB and MB002000JWWQA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bcf5358eccd846f48b83981d44","SupportedDevices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.38.51"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.38.51"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.38.51"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.38.51"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-open-2.44.0-1.1.x86_64.rpm","SHA1Sum":"f3399dd59437348de92f40e2c02280dc3225334f","SHA256Sum":"4866a67ba9c6ad8074a34a4da86679a3004a76150c99ff89107fc23ac6dc6d10","SHA512Sum":"ed94da57668fdabb2db81a5444b8f0eb6a781455deaf0277e55b3560766334be294d3139c46117bde1af9d9772b1ac7194278a03accdedc9162b4b5cd4bafc41"}],"ComponentSizeInKB":5920,"CompsigList":["firmware-nic-bcm-open-2.44.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/CP072706.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/CP072706.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/nic_fw/BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/nic_fw/BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/nic_fw/BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/nic_fw/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-open-2.44.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072706.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072706.scexe"],"Name":"firmware-nic-bcm-open-2.44.0-1.1.x86_64.rpm","SHA1Sum":"f3399dd59437348de92f40e2c02280dc3225334f","SHA256Sum":"4866a67ba9c6ad8074a34a4da86679a3004a76150c99ff89107fc23ac6dc6d10","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"2.44.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Broadcom NX1 Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_OPEN","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_089b24726e0b4793bc34dc6be4","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U58","U58","H10","H10","U47","U46","A42","A42","A43","U46","03030202","03020102","U70"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-igb-5.20.28-1.rhel10u1.x86_64.rpm","SHA1Sum":"03802c8bedea627501fc021353951d0cafca3307","SHA256Sum":"2d56866c08df307f4ce0316934b4594b62e9fba5bcf35db142b69b5696ae63ee","SHA512Sum":"c275dcd6e70e103e69ce0b317159f06484a0f43344a792369910c71470288814cc2758dcbf794cb76c286bc2703434906733dd1e06079c8823542fe4024deb73"}],"ComponentSizeInKB":225,"CompsigList":["kmod-igb-5.20.28-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-igb.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/igb/igb.ko","./usr/share/doc/kmod-igb","./usr/share/doc/kmod-igb/COPYING","./usr/share/doc/kmod-igb/README","./usr/share/doc/kmod-igb/pci.updates","./usr/share/man/man7/igb.7.gz","./usr/share/smartupdate/kmod-igb/component.xml"],"Name":"kmod-igb-5.20.28-1.rhel10u1.x86_64.rpm","SHA1Sum":"03802c8bedea627501fc021353951d0cafca3307","SHA256Sum":"2d56866c08df307f4ce0316934b4594b62e9fba5bcf35db142b69b5696ae63ee","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca93656a5"],"TypeOfChange":"1","Version":"5.20.28-1"},{"Checksum":[{"Filename":"kmod-igb-5.20.28-1.rhel10u2.x86_64.rpm","SHA1Sum":"8a5c885696591753ab35e03dc350e4659c725b9e","SHA256Sum":"76b6f81a0df829b385ce73e6002df19a45113c916bd36e0849a95ac17188a55c","SHA512Sum":"97f79b1bdf979b3237b2c1a0f6b3df7cd6e06f25161d0a92b60fa3bc99e7ce2c33d6fd2f6f13a2191936ed4ad742000b19d782dfb93f3e37d1f04c12316cb9db"}],"ComponentSizeInKB":226,"CompsigList":["kmod-igb-5.20.28-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-igb.conf","./lib/modules/6.12.0-211.7.1.el10_2.x86_64/extra/igb/igb.ko","./usr/share/doc/kmod-igb","./usr/share/doc/kmod-igb/COPYING","./usr/share/doc/kmod-igb/README","./usr/share/doc/kmod-igb/pci.updates","./usr/share/man/man7/igb.7.gz","./usr/share/smartupdate/kmod-igb/component.xml"],"Name":"kmod-igb-5.20.28-1.rhel10u2.x86_64.rpm","SHA1Sum":"8a5c885696591753ab35e03dc350e4659c725b9e","SHA256Sum":"76b6f81a0df829b385ce73e6002df19a45113c916bd36e0849a95ac17188a55c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca93656a5"],"TypeOfChange":"1","Version":"5.20.28-1"}],"InstallationDependency":{},"Name":"HPE Intel igb Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-igb","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4b6b904535cd4dc991700d3a79","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H10","H10","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069585.exe","SHA1Sum":"45016bfe2fb59461b84aee0821288b120871583f","SHA256Sum":"362a82f7b1b8efbbe0d43dd936b27a0d56a7cc9b4dea71cad9b2c7c5bf8a59e6","SHA512Sum":"e2543668677ac9f5a8bc2b5f780d6419584317d849134777820312084f9540eef0635d247e1212568b137558958437fa4e7152e8d22cfebb35a0c846f033824c"}],"ComponentSizeInKB":868,"CompsigList":["cp069585.compsig"],"FileList":["cp069585.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"Name":"cp069585.exe","SHA1Sum":"45016bfe2fb59461b84aee0821288b120871583f","SHA256Sum":"362a82f7b1b8efbbe0d43dd936b27a0d56a7cc9b4dea71cad9b2c7c5bf8a59e6","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.732.3.0"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers Driver for Microsoft Windows 2019 edition","PackageFormat":"","PerDeviceInstallTimeSeconds":400,"RebootRequired":"yes","SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_49fe9081c9ee40c6ad89c24ecc","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A59"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.38.51"}]},"Files":[{"Checksum":[{"Filename":"cp072705.exe","SHA1Sum":"22146863f7859e611bd32fb884cf5d2cf7aaa179","SHA256Sum":"2bd3b1ebce0fec7da3875484aee12c31fb75b36f132f15cf23774519124a8311","SHA512Sum":"5a0128c6119780c3d615a3d276bbd450504466812e155d275d4eb6a2fc43009b1ed55114a30b75f3e5db81866f2ee9c35d20139be80bca97527896bc44375130"}],"ComponentSizeInKB":7857,"CompsigList":["cp072705.compsig"],"FileList":["bcmnicfwupg.exe","BMAPIa.dll","cp072705.xml","cpqsetup.exe","FW/","FW/331FLR-4x1G-14E4-1657-103C-169D.BIN","FW/331i-4x1G-14E4-1657-103C-22BE.BIN","FW/331T-4x1G-14E4-1657-103C-3383.BIN","FW/332i-2x1G-14E4-165F-103C-22E8.BIN","FW/332T-2x1G-14E4-165F-103C-1786.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp072705.exe","SHA1Sum":"22146863f7859e611bd32fb884cf5d2cf7aaa179","SHA256Sum":"2bd3b1ebce0fec7da3875484aee12c31fb75b36f132f15cf23774519124a8311","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"5.4.8.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NX1 Online Firmware Upgrade Utility Windows Server x64 Editions for HPE ProLiant Gen10 server series Only","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BcmNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_43d9dd051d4f4b12b6e5f0dbf5","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-35fd24601f_0HPD5-2.1_amd64.deb","SHA1Sum":"068ad755eee3cae619b805e3bd193d130a0a6e8c","SHA256Sum":"1d7ca12ec76c2a4cf42b6ac1097ae2ffe8fef575b037096f3ef9105c44045cfd","SHA512Sum":"733cf5c36e34f72b69a2688d1e5710eb0494941bb43f25e98201073f19ae1c602f0487770d80c8f04d3b01e8a2093fb65818ad19f4a994b5b36a5ce50c881cac"}],"ComponentSizeInKB":3656,"CompsigList":["firmware-hdd-35fd24601f_0HPD5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/CP071752.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/GPM1643ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071752.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071752.scexe"],"Name":"firmware-hdd-35fd24601f_0HPD5-2.1_amd64.deb","SHA1Sum":"068ad755eee3cae619b805e3bd193d130a0a6e8c","SHA256Sum":"1d7ca12ec76c2a4cf42b6ac1097ae2ffe8fef575b037096f3ef9105c44045cfd","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ab822b19174f4e0cbbab720147","SupportedDevices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A46_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071512.exe","SHA1Sum":"489c9bf911bd59453436400eae81d70a47b35975","SHA256Sum":"c63a149ec04301c4b163ee5affe523684a93f72391aaa38ee7a3797ba1f75dcd","SHA512Sum":"62b818e1cb6106cb59aeca4aee39724d2d1602fe39a5163e99c007b58a6fb27f767fa9d05947bc9386c6c1cfb7bc11aa67fa70e2738430635c6967a05f2655a4"}],"ComponentSizeInKB":33436,"CompsigList":["cp071512_part1.compsig","cp071512_part2.compsig"],"FileList":["A46_4.04_04_02_2026.signed.flash","cp071512.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071512.exe","SHA1Sum":"489c9bf911bd59453436400eae81d70a47b35975","SHA256Sum":"c63a149ec04301c4b163ee5affe523684a93f72391aaa38ee7a3797ba1f75dcd","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL225n Gen10 Plus (A46) Server","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f2c02701d3864e43b8528557eb","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A46"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"cp068655.exe","SHA1Sum":"414eaee2cf6ad92f24df9e62e00e9049c2bdb5ff","SHA256Sum":"3402f61eb05bdfdc21606c18a2d82388f956d0aec7913d45fc35a9da2c9fbf13","SHA512Sum":"f5fd173a5ca3eaf9d35694646b4e921d07c2766dde83c894ff25903c67b08fba454b172e1e3869046f8b6a02f1ee0056a953c1b264edc0ebc83f6d081b537c5b"}],"ComponentSizeInKB":4397,"CompsigList":["cp068655.compsig"],"FileList":["cp068655.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SSKYBT512EDB.rel"],"Name":"cp068655.exe","SHA1Sum":"414eaee2cf6ad92f24df9e62e00e9049c2bdb5ff","SHA256Sum":"3402f61eb05bdfdc21606c18a2d82388f956d0aec7913d45fc35a9da2c9fbf13","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb460e6ce42541ccaa5dad6a16","SupportedDevices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072315.zip","SHA1Sum":"7f2c3192ac45f20acb4f42508c71dceb6b649fc8","SHA256Sum":"9321acdbbebc546a09ff4b373a739d07476e314a96ea334268fa36d8afb40c31","SHA512Sum":"0339c782c1f02118ff19052af5cdb965bb553add5e5a0d05402f2a156a90fab556f39d52a0d28f91107c4c3f19c86e97799275dc2f45f700a4a1bf40b7129404"}],"ComponentSizeInKB":260,"CompsigList":["cp072315.compsig"],"FileList":["/cp072315.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/index.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/vib20/i40en/INT_bootbank_i40en_2.12.1.0-1OEM.900.0.24755229.vib","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/i40en-6330660836031686988.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.xml"],"Name":"cp072315.zip","SHA1Sum":"7f2c3192ac45f20acb4f42508c71dceb6b649fc8","SHA256Sum":"9321acdbbebc546a09ff4b373a739d07476e314a96ea334268fa36d8afb40c31","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"i40en","Version":"2.12.1.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Intel i40en Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-i40en:2.12.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.12.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2267438c81f744a1ada8ec3531","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U36","U43","U41","U33","U44","A47","A48","U47","U37","A46","U47","U38","U38","U48","02020001","03020101","A42","U56","U61","U60","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp073082.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.926"}]},"Files":[{"Checksum":[{"Filename":"cp073086.exe","SHA1Sum":"6fb44f4a314c09227bf76364e33ca5021c727e1b","SHA256Sum":"e12e63894c23e2294ce11007edb873c84c0351bbdd7d8f27cbdd557d509de1ba","SHA512Sum":"c5f3e4d094361bda0c1e0b75207029f975c5dc9a6ac06ba1a3731aa5a02a3c1703ad0983849515d3b4b18c98e8f1d44b267277fec6330bb963a1bc02071bc933"}],"ComponentSizeInKB":8842,"CompsigList":["cp073086.compsig"],"FileList":["cp073082.compsig","cp073082.zip","cp073086.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp073086.exe","SHA1Sum":"6fb44f4a314c09227bf76364e33ca5021c727e1b","SHA256Sum":"e12e63894c23e2294ce11007edb873c84c0351bbdd7d8f27cbdd557d509de1ba","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.926"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_033cedda1f3743a680c65c9f30","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U56","H10","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-megaraid_sas-07.738.06.0_rhel9u8-1.x86_64.rpm","SHA1Sum":"05af77e1bbcce1ff3434c6401b592a6422f08843","SHA256Sum":"dc4be56fffd3fc3da8ebc75e99d9750e39b329de74864aea36788453ebcb2bea","SHA512Sum":"e4c98cb621cb4fcf098ba6fc3b95570d77185cbd9436cee8f396415e625b07b57e1a7f1b1ee46fd34f4dd2788aee41f0a9f1330ebe4473fbfdc79336fbf92c54"}],"ComponentSizeInKB":141,"CompsigList":["kmod-megaraid_sas-07.738.06.0_rhel9u8-1.x86_64.compsig"],"FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/megaraid_sas","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"Name":"kmod-megaraid_sas-07.738.06.0_rhel9u8-1.x86_64.rpm","SHA1Sum":"05af77e1bbcce1ff3434c6401b592a6422f08843","SHA256Sum":"dc4be56fffd3fc3da8ebc75e99d9750e39b329de74864aea36788453ebcb2bea","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.738.06.0"},{"Checksum":[{"Filename":"kmod-megaraid_sas-07.738.06.0_rhel9u7-1.x86_64.rpm","SHA1Sum":"fd5853c0a278b9785de538085264cdba1005c302","SHA256Sum":"5283b7771683b058ddb82a816476d55154bdfc3db8a509be00f16d2a33d3b69b","SHA512Sum":"0d49a2f4bb6d00149ac5a4b7d73700069e6514f9d73cce900789f3b9cfa0a6328c5fb00e4a88c0f880bc4b0b3805c355060e93342c3fa31f04fa2388c4106e3d"}],"ComponentSizeInKB":144,"CompsigList":["kmod-megaraid_sas-07.738.06.0_rhel9u7-1.x86_64.compsig"],"FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/megaraid_sas","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"Name":"kmod-megaraid_sas-07.738.06.0_rhel9u7-1.x86_64.rpm","SHA1Sum":"fd5853c0a278b9785de538085264cdba1005c302","SHA256Sum":"5283b7771683b058ddb82a816476d55154bdfc3db8a509be00f16d2a33d3b69b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.738.06.0"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1c34eb23d4374bd59fe1dc78ee","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U46","U30","U32","U61","A42","A43","A43","A42","U60","U63","U59","U46","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD6"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD6"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD6"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070061.zip","SHA1Sum":"e2ae25f66e2f3ece746aea82be3cc27bc2ef7b13","SHA256Sum":"59ded6acc4d05daaca09761f08f36caee5e0869717668403a6fbb639dd1f2340","SHA512Sum":"32da9a3fe31f7eaf9db87aebc8e80ecb855997f4ebe4060a5519a544a4c69be48b0ec314f2837025d9f7ff8ead4c87c8267cfed298fdaac657a5907a3376e757"}],"ComponentSizeInKB":19444,"CompsigList":["CP070061.compsig"],"FileList":["/CP070061_BUILD_15.data","/CP070061.vmexe64","/CP070061.vmfile","/CP070061_VMw.zip","/CP070061.xml","/payload.json","/CP070061_VMw.zip/index.xml","/CP070061_VMw.zip/vendor-index.xml","/CP070061_VMw.zip/metadata.zip","/CP070061_VMw.zip/vib20/CP070061/HPE_bootbank_CP070061_HPD6.15-8.0.0.20613240.vib","/CP070061_VMw.zip/metadata.zip/vendor-index.xml","/CP070061_VMw.zip/metadata.zip/vmware.xml","/CP070061_VMw.zip/metadata.zip/vibs/CP070061--4504899403480904118.xml","/CP070061_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070061_HPD6.15-8.0.0.20613240.xml"],"Name":"CP070061.zip","SHA1Sum":"e2ae25f66e2f3ece746aea82be3cc27bc2ef7b13","SHA256Sum":"59ded6acc4d05daaca09761f08f36caee5e0869717668403a6fbb639dd1f2340","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070061","Version":"HPD6.15-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a22e7e8924b94faea523da1227","SupportedDevices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-035a863453-HPK5-11.1.x86_64.rpm","SHA1Sum":"84b6e1ab9ec2aa2f3679803d3a98b07af2adcf8f","SHA256Sum":"ff427c4e5df56b545d8ab5f392faf825b40c3009f4eb72e7f4ae79200700498e","SHA512Sum":"eb92bf6eaea66ceab8af4d12ff0f94ba10f66225cc3762a2e36cb674dbfe2894253f0d5e59468542db3b4c7074427f0ab49bb9005ddfb5d57cf8a6c562ce7e25"}],"ComponentSizeInKB":7202,"CompsigList":["firmware-hdd-035a863453-HPK5-11.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/CP068909.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/KPE80X0AHPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-11.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068909.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068909.scexe"],"Name":"firmware-hdd-035a863453-HPK5-11.1.x86_64.rpm","SHA1Sum":"84b6e1ab9ec2aa2f3679803d3a98b07af2adcf8f","SHA256Sum":"ff427c4e5df56b545d8ab5f392faf825b40c3009f4eb72e7f4ae79200700498e","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d4c8d4a771074416b3a178335c","SupportedDevices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-4fbb6d96e5-HPG3-2.1.x86_64.rpm","SHA1Sum":"a2d00408c228de1796f0120ddccd8473e7ede6bc","SHA256Sum":"91206b784baba0f3f8c897ca499f5f42d47e5d754e1178e97292b334db620fa2","SHA512Sum":"b94e12f407d6f31bb7e7ba0647ad7d0f3c8bdb78aea4e0e9539e123a8549277511594c586995dfc4ab746c2fc3dc21038edb26810c0354b23b2225fb01ce7bfd"}],"ComponentSizeInKB":5764,"CompsigList":["firmware-hdd-4fbb6d96e5-HPG3-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/CP068838.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/SHPEEVSBPTG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-4fbb6d96e5-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068838.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068838.scexe"],"Name":"firmware-hdd-4fbb6d96e5-HPG3-2.1.x86_64.rpm","SHA1Sum":"a2d00408c228de1796f0120ddccd8473e7ede6bc","SHA256Sum":"91206b784baba0f3f8c897ca499f5f42d47e5d754e1178e97292b334db620fa2","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6022262f43ce41b4a042d38bde","SupportedDevices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d4be2aecbb_0HPD6-2.1_amd64.deb","SHA1Sum":"b0ad241639c29f337810e02d5df8d5dc5f9f5739","SHA256Sum":"162eeef3c39842823788bff7872c4ad89710ba39b6fbd8dc047604cb1f8efd0a","SHA512Sum":"6a4ca3cd3b7bb0f1e4babd06bf8b9d0fe19d4581ba5b7f5f8ed2b7ac85bb6faa9fd182bdae61d8f0a9b1214d6a58c2983d28b03f0074127d4d9d80895a7f533d"}],"ComponentSizeInKB":4665,"CompsigList":["firmware-hdd-d4be2aecbb_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/CP071776.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/SCIMARBPNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071776.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071776.scexe"],"Name":"firmware-hdd-d4be2aecbb_0HPD6-2.1_amd64.deb","SHA1Sum":"b0ad241639c29f337810e02d5df8d5dc5f9f5739","SHA256Sum":"162eeef3c39842823788bff7872c4ad89710ba39b6fbd8dc047604cb1f8efd0a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB002000JYDNE and MB004000JYDPB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4ec7fc8ba9a6401d8dd66db3d7","SupportedDevices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-017797f12e_0HPD4-2.1_amd64.deb","SHA1Sum":"054f49920b24da13960abd6902cb79cc19e87c2b","SHA256Sum":"c125f3e09ae9ee804d27122d23d0310b03751ea749585503673cbf96eaf897ff","SHA512Sum":"e3375a2a2f1dae23b9f7af7312c84082fa399e238456bd5458cb5bba99ebf24d196b8049446b2d0965bdf338115b12e707894a43b8dbe4b97ca67c92140a2110"}],"ComponentSizeInKB":5242,"CompsigList":["firmware-hdd-017797f12e_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/CP071785.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/PCHFA2BP.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071785.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071785.scexe"],"Name":"firmware-hdd-017797f12e_0HPD4-2.1_amd64.deb","SHA1Sum":"054f49920b24da13960abd6902cb79cc19e87c2b","SHA256Sum":"c125f3e09ae9ee804d27122d23d0310b03751ea749585503673cbf96eaf897ff","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JXUCC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c21f4a1289bb45b79eecb199ad","SupportedDevices":["4d2340a5-3042-3431-3030-304a58554343"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-017797f12e-HPD4-6.1.x86_64.rpm","SHA1Sum":"5ceb4708a2a187507028a2a169407275529e130d","SHA256Sum":"fd181315d21147383bfa18d51645c0c546d24103952e849c627a118bd73d0222","SHA512Sum":"3d6ba8f8901888dd2cdbf00a502e7463d80ab3e81ee4590207f17b93721f96298b48df4c87f2fd0717c25d027040c9e1015ab42d54b27f3efdc8c1ada7935933"}],"ComponentSizeInKB":7025,"CompsigList":["firmware-hdd-017797f12e-HPD4-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/CP068851.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/PCHFA2BP.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-017797f12e-HPD4-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068851.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068851.scexe"],"Name":"firmware-hdd-017797f12e-HPD4-6.1.x86_64.rpm","SHA1Sum":"5ceb4708a2a187507028a2a169407275529e130d","SHA256Sum":"fd181315d21147383bfa18d51645c0c546d24103952e849c627a118bd73d0222","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JXUCC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_118afb87880649a9ac415ea8d3","SupportedDevices":["4d2340a5-3042-3431-3030-304a58554343"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"cp068636.exe","SHA1Sum":"461944992100242d97babe2abc7fbe320ee1a718","SHA256Sum":"3ff362b26afe88ce3714c2b38fad6888b4bb70f19c4f630d729e6e86803710c1","SHA512Sum":"258b90c3908a1e6211198e7eb78a6ac35d14aec066fc216caca13681b06e4116976b1bd181fb35f7dbc3f53c2b7f33372cd867425feb30dbf286a41bc0b5acd3"}],"ComponentSizeInKB":5844,"CompsigList":["cp068636.compsig"],"FileList":["cp068636.xml","cpqsetup.exe","KPE80X0AHPK5.rel","payload.json","setup.dll"],"Name":"cp068636.exe","SHA1Sum":"461944992100242d97babe2abc7fbe320ee1a718","SHA256Sum":"3ff362b26afe88ce3714c2b38fad6888b4bb70f19c4f630d729e6e86803710c1","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8bf4346a35984e31809f5fa031","SupportedDevices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.38.51"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.38.51"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.38.51"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.38.51"}]},"Files":[{"Checksum":[{"Filename":"CP072707.zip","SHA1Sum":"1074d586d8d44036ddf228638fe9440d69bb207b","SHA256Sum":"d5fe49ad026e113d6d1191602c131f989c4b5d8252ac4379d6d800bbf4e05dff","SHA512Sum":"c7422b90a6d9c42ce2146939cfb1168836d7714d17629191efbb5c8b6220551031dfbd5440b9e5704b959b4fd4464010011231b30f40a914aa7af18e0158ad33"}],"ComponentSizeInKB":16667,"CompsigList":["CP072707.compsig"],"FileList":["/CP072707_BUILD_1.data","/CP072707.vmexe64","/CP072707.vmfile","/CP072707_VMw.zip","/CP072707.xml","/payload.json","/CP072707_VMw.zip/index.xml","/CP072707_VMw.zip/vendor-index.xml","/CP072707_VMw.zip/metadata.zip","/CP072707_VMw.zip/vib20/CP072707/HPE_bootbank_CP072707_1.45.0.1-8.0.0.20613240.vib","/CP072707_VMw.zip/metadata.zip/vendor-index.xml","/CP072707_VMw.zip/metadata.zip/vmware.xml","/CP072707_VMw.zip/metadata.zip/vibs/CP072707--1454237943900583208.xml","/CP072707_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072707_1.45.0.1-8.0.0.20613240.xml"],"Name":"CP072707.zip","SHA1Sum":"1074d586d8d44036ddf228638fe9440d69bb207b","SHA256Sum":"d5fe49ad026e113d6d1191602c131f989c4b5d8252ac4379d6d800bbf4e05dff","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"1.45.0","VibList":[{"Name":"CP072707","Version":"1.45.0.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Broadcom NX1 Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_OPEN","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6c869096069c434c9c4dde60ec","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U58","U58","H10","H10","U47","U46","A42","A42","A43","U46","U46","U70"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"16_35_8008-MCX512F-ACH_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30116","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"16_35_8008-MCX512F-ACH_Ax_Bx.pldm.fwpkg","SHA1Sum":"1c8fc46d9362c4006516cb20ffee972052e50fbd","SHA256Sum":"3d2ef2b0962bdb360c4bd2a96d3c9acef1c6466e9bc163f7d350b4e3549d111d","SHA512Sum":"1b8e73f67071bbb9f9b9217a062347d565ef4f0fb00c1e75724e6d709802adf3088d84688730c9a10cf78ecbbba384278cc42e37a10907badcd5a7689b244357"}],"ComponentSizeInKB":5216,"CompsigList":[],"FileList":["16_35_8008-MCX512F-ACH_Ax_Bx.pldm.signed","16_35_8008-MCX512F-ACH_Ax_Bx.pldm.xml","payload.json"],"Name":"16_35_8008-MCX512F-ACH_Ax_Bx.pldm.fwpkg","SHA1Sum":"1c8fc46d9362c4006516cb20ffee972052e50fbd","SHA256Sum":"3d2ef2b0962bdb360c4bd2a96d3c9acef1c6466e9bc163f7d350b4e3549d111d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715b30116"],"TypeOfChange":"1","Version":"16.35.8008"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package(FWPKG) for HPE Ethernet 10/25Gb 2-port SFP28 MCX512F-ACHT Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX512F-ACHT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0691dac6f40a41d9b4ebca041a","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0","10.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U47","A46","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U30","U32","U60","U54","U54"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"CP070957.zip","SHA1Sum":"fde7e82f1ab91c07778c3e3d49bf37429692f965","SHA256Sum":"394f34f40ed11e75037359ce898a935ec053d5694b60927496959dd2654519b4","SHA512Sum":"0136319a521791e2ee01d41ab6801aa7e2f470cf8c2a700d4bc3923a5b4f3830155574895a3c2caee6278c0d8fa78b9153c785fbeb4cb8ded613ede45621e62d"}],"ComponentSizeInKB":17698,"CompsigList":["CP070957.compsig"],"FileList":["/CP070957_BUILD_7.data","/CP070957.vmexe64","/CP070957.vmfile","/CP070957_VMw.zip","/CP070957.xml","/payload.json","/CP070957_VMw.zip/index.xml","/CP070957_VMw.zip/vendor-index.xml","/CP070957_VMw.zip/metadata.zip","/CP070957_VMw.zip/vib20/CP070957/HPE_bootbank_CP070957_HPG6.7-8.0.0.20613240.vib","/CP070957_VMw.zip/metadata.zip/vendor-index.xml","/CP070957_VMw.zip/metadata.zip/vmware.xml","/CP070957_VMw.zip/metadata.zip/vibs/CP070957--1247269693036596716.xml","/CP070957_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070957_HPG6.7-8.0.0.20613240.xml"],"Name":"CP070957.zip","SHA1Sum":"fde7e82f1ab91c07778c3e3d49bf37429692f965","SHA256Sum":"394f34f40ed11e75037359ce898a935ec053d5694b60927496959dd2654519b4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP070957","Version":"HPG6.7-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000GWJRR and MB008000GWJRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e6345b224b6f4bc3acfd2be67b","SupportedDevices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-iavf-kmp-default-4.13.35_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"a967012ef6cd005bd854ffba73aef987e462871b","SHA256Sum":"90b084b63dd754c348036e467b87b1577061db0ecad669ddc1ef4667809107db","SHA512Sum":"f5797ec7b88df47fcd808bf13f29fa319aa17733b699caa75403203145890c5cfc3fe635ef3685c260918c91377f72b448e3029a2efec658a4b00ce6c2b9e40a"}],"ComponentSizeInKB":3469,"CompsigList":["hp-iavf-kmp-default-4.13.35_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-iavf","./lib/modules/6.4.0-150600.21-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"Name":"hp-iavf-kmp-default-4.13.35_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"a967012ef6cd005bd854ffba73aef987e462871b","SHA256Sum":"90b084b63dd754c348036e467b87b1577061db0ecad669ddc1ef4667809107db","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"TypeOfChange":"1","Version":"4.13.35-1"},{"Checksum":[{"Filename":"hp-iavf-kmp-default-4.13.35_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"5415f7078a36dff46f1d79dcebbf6ac76001edbd","SHA256Sum":"1ccb1b268f7a9eb96b67a42d88a6764dbfa9fea722adbf0df4a0dc25c4450445","SHA512Sum":"98868f333baaf18d274d3c8109bd5d135cfd2c249740ce90ab8deda4b9bebed10c44c9c30c25c7cb2a3cff931d556070a0f94ceb3b8a64b1821437978d370555"}],"ComponentSizeInKB":188,"CompsigList":["hp-iavf-kmp-default-4.13.35_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-iavf","./lib/modules/6.4.0-150700.51-default/updates/hp-iavf/iavf.ko","./usr/share/smartupdate/hp-iavf-kmp-default/component.xml"],"Name":"hp-iavf-kmp-default-4.13.35_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"5415f7078a36dff46f1d79dcebbf6ac76001edbd","SHA256Sum":"1ccb1b268f7a9eb96b67a42d88a6764dbfa9fea722adbf0df4a0dc25c4450445","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8201731a"],"TypeOfChange":"1","Version":"4.13.35-1"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]}]}]},"Name":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-iavf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2136780aa1c74f3d88e71499ad","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-15ff8086000c","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"netxtreme2-kmp-default-7.15.27_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"6b5c60cecf0d407c5978510441791c4c7c97cabc","SHA256Sum":"dddfb576244aa72d1609694c9076e6a50efd5b5dc10c9e227a753e903d406781","SHA512Sum":"6275cf8a6eb12c5cda71a1dc079892f14dfacccf388b5d87faea517abcf347c1266319f19d3b4d132833af6f981d56684d655e6deb964ed90eeaee865d3aa728"}],"ComponentSizeInKB":8359,"CompsigList":["netxtreme2-kmp-default-7.15.27_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/bnx2.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2fc.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2i.ko","./lib/modules/6.4.0-150600.21-default/updates/bnx2x.ko","./lib/modules/6.4.0-150600.21-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"Name":"netxtreme2-kmp-default-7.15.27_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"6b5c60cecf0d407c5978510441791c4c7c97cabc","SHA256Sum":"dddfb576244aa72d1609694c9076e6a50efd5b5dc10c9e227a753e903d406781","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"TypeOfChange":"1","Version":"7.15.27-1"},{"Checksum":[{"Filename":"netxtreme2-kmp-default-7.15.27_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"fa6d89e36fa58ba276e874d49be23cf677bf6f71","SHA256Sum":"c2f6ffc6dfa9e59f1af46c03bcc763ad00ba34d29739b68b94a3ced9c5f47a47","SHA512Sum":"653b2ee973f4bc44786c22997da1b7d33ef1cc48be95dc2158a09722cfe705c656d15a31a97aa48f38683a61b9946ece714dc8d08a97a23f9a45750f46fa1152"}],"ComponentSizeInKB":8405,"CompsigList":["netxtreme2-kmp-default-7.15.27_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/bnx2.ko","./lib/modules/6.4.0-150700.51-default/updates/bnx2fc.ko","./lib/modules/6.4.0-150700.51-default/updates/bnx2i.ko","./lib/modules/6.4.0-150700.51-default/updates/bnx2x.ko","./lib/modules/6.4.0-150700.51-default/updates/cnic.ko","./usr/share/smartupdate/netxtreme2-kmp-default/component.xml"],"Name":"netxtreme2-kmp-default-7.15.27_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"fa6d89e36fa58ba276e874d49be23cf677bf6f71","SHA256Sum":"c2f6ffc6dfa9e59f1af46c03bcc763ad00ba34d29739b68b94a3ced9c5f47a47","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb"],"TypeOfChange":"1","Version":"7.15.27-1"}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"netxtreme2-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dcd419b0c9944057bdc7c4a171","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16af103c1933","a6b1a447-382a-5a4f-14e4-16ad103c1917","a6b1a447-382a-5a4f-14e4-16ae103c3382","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-elx-lpfc-14.4.731.20-1.rhel10u2.x86_64.rpm","SHA1Sum":"dc6a20049b096955362ad5c2c4f3f6f5949a3f58","SHA256Sum":"4ed6208e8e629204cf3d4811b917dde973afe11fa5911687afe4c9bf09c28121","SHA512Sum":"15e06034963fc72fecbfb67d0696fc94026bfc50defc7c2ecf4cacdf1ff6978ea60c17918ff8990ccf68b5cf98509db5b2d3ae5e58685b8ba91ca69de516a3c4"}],"ComponentSizeInKB":836,"CompsigList":["kmod-elx-lpfc-14.4.731.20-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/elx-lpfc","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"Name":"kmod-elx-lpfc-14.4.731.20-1.rhel10u2.x86_64.rpm","SHA1Sum":"dc6a20049b096955362ad5c2c4f3f6f5949a3f58","SHA256Sum":"4ed6208e8e629204cf3d4811b917dde973afe11fa5911687afe4c9bf09c28121","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 10 Server Update 2 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5c78fd5e00924adda4bc86d129","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8e1e8083c5-HPG3-6.1.x86_64.rpm","SHA1Sum":"5f2baa8ff9e52995caf21da4c0ed2c12485dffd4","SHA256Sum":"0a2bb6f2f4d83fccda450c12230402e3e4a4f53613c885bd10075a0ac293b970","SHA512Sum":"dc59376aacb7940d6835381d7be4c4e4e4721cc3be7acd8c030699f43b0652ec6a16a74708be460476b2d143fdd463839cb96da1b4fe0b5c9cab128825d35161"}],"ComponentSizeInKB":9299,"CompsigList":["firmware-hdd-8e1e8083c5-HPG3-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/CP068908.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/K503HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068908.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068908.scexe"],"Name":"firmware-hdd-8e1e8083c5-HPG3-6.1.x86_64.rpm","SHA1Sum":"5f2baa8ff9e52995caf21da4c0ed2c12485dffd4","SHA256Sum":"0a2bb6f2f4d83fccda450c12230402e3e4a4f53613c885bd10075a0ac293b970","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_426ba3dc2e0c4272b5336f0e13","SupportedDevices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072095.exe","SHA1Sum":"135af32a09060d7a899431988304d310aebf38ed","SHA256Sum":"c142bb0d5d47df73c4312dca608b2ad04f31799e42f550220ce3a150573b2cb0","SHA512Sum":"57af915635523f16e1309e8546814d12c66fab17f4f2d718cf453e887577309e41ebc44f8c6a451c34165b8cd3aab811e96348542bd15d90f1bbd8efd0736e00"}],"ComponentSizeInKB":10194,"CompsigList":["cp072095.compsig"],"FileList":["cp072095.xml","cpqsetup.exe","cp_data.xml","genericmsi.dll","SSA66590_X64.msi"],"Name":"cp072095.exe","SHA1Sum":"135af32a09060d7a899431988304d310aebf38ed","SHA256Sum":"c142bb0d5d47df73c4312dca608b2ad04f31799e42f550220ce3a150573b2cb0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc02887d0"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"ssa.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssa\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0211f99c09934b039fd5186f8f","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","A46","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","O43","U48","I44","I45","U58","U58","U63","A56","A56","U54","A55","U54","U58","A55","U59","U63","U54","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U65","U65","U57","U62","U68","U68","U72","A66","A66","U68","U71","U71"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-24384980ec-HPD2-4.1.x86_64.rpm","SHA1Sum":"c2ab12e5d3e976a0bcde54c2daeda418364bef8e","SHA256Sum":"0806423c340cc0b844c0d93e0e6ea3edc8eaef1b634f056ce0a3c4953f0b4ea8","SHA512Sum":"84115a3ddb3da4e7aed3eaff9c7a0d2f89cd1852cf817fb788d4f0fe8507283dea65c8c144a97d4b38ca99d440fccc31e2dea6a977a0062fdd2fe54902d81a39"}],"ComponentSizeInKB":5421,"CompsigList":["firmware-hdd-24384980ec-HPD2-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/CP068853.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/WBCQssssASFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068853.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068853.scexe"],"Name":"firmware-hdd-24384980ec-HPD2-4.1.x86_64.rpm","SHA1Sum":"c2ab12e5d3e976a0bcde54c2daeda418364bef8e","SHA256Sum":"0806423c340cc0b844c0d93e0e6ea3edc8eaef1b634f056ce0a3c4953f0b4ea8","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_87a0067ffcf54b28965bb0d063","SupportedDevices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Files":[{"Checksum":[{"Filename":"cp068652.exe","SHA1Sum":"0b25b6cf45cc22f587cb896d91381525e9c5ed7b","SHA256Sum":"3c26def9c3523a9eb1d796282173658dc5d1347022a56603e0690ef56e272277","SHA512Sum":"f0d70a32c50e41e20f02218874b43375601bac991b5f3c005c59e23b43612517f8635c14809a6e43b4cde39ea259f54738282e00c94c9b82161a0e5a9a95e0d3"}],"ComponentSizeInKB":4581,"CompsigList":["cp068652.compsig"],"FileList":["cp068652.xml","cpqsetup.exe","KACM6ALFGPK6.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068652.exe","SHA1Sum":"0b25b6cf45cc22f587cb896d91381525e9c5ed7b","SHA256Sum":"3c26def9c3523a9eb1d796282173658dc5d1347022a56603e0690ef56e272277","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_830635266472425cad538063c1","SupportedDevices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Files":[{"Checksum":[{"Filename":"cp072205.exe","SHA1Sum":"b60be39524fcc1ea60645b0154b230dadfb4e02d","SHA256Sum":"63b4cc7429a4f83e20088bc964e091068f02790f7ba5b3d5c6dfefaf2612a0ca","SHA512Sum":"7e1acddd61e9965eed631aabe22d4eecd4ba2002914e97bc02375dd2c8de214302de72b70398acb3c1bf7584d46461581c1c98419aa73b55ee7c318c66f23852"}],"ComponentSizeInKB":5002,"CompsigList":["cp072205.compsig"],"FileList":["Config.xml","cp072205.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Tormore-Release-2.74-build-001.bin","VDUFlash.dll"],"Name":"cp072205.exe","SHA1Sum":"b60be39524fcc1ea60645b0154b230dadfb4e02d","SHA256Sum":"63b4cc7429a4f83e20088bc964e091068f02790f7ba5b3d5c6dfefaf2612a0ca","SoftwarePlatforms":[],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2972f8783d574ccebb8ad683e0","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE10X0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_U3_KPE10x0U3DK2.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b594c4543","Version":"HPK2"},{"DeviceName":"SKHynix-PE10X0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_U3_KPE10x0U3DK2.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b594c484c","Version":"HPK2"},{"DeviceName":"SKHynix-PE10X0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_U3_KPE10x0U3DK2.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b594c484e","Version":"HPK2"},{"DeviceName":"SKHynix-PE10X0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_U3_KPE10x0U3DK2.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b594c4542","Version":"HPK2"},{"DeviceName":"SKHynix-PE10X0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_U3_KPE10x0U3DK2.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b594c4846","Version":"HPK2"},{"DeviceName":"SKHynix-PE10X0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_U3_KPE10x0U3DK2.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b594c4848","Version":"HPK2"},{"DeviceName":"SKHynix-PE10X0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE10X0_U3_KPE10x0U3DK2.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b594c484b","Version":"HPK2"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PE10X0_U3_KPE10x0U3DK2.fwpkg","SHA1Sum":"15ccce8c0894dbd08a55732cdd57cc266debc606","SHA256Sum":"a5cd31be4795d9cc76b6ff4665cd4c9cb2f78ec3d51a0fb026e0c09ce4fa7b5a","SHA512Sum":"ed9e6275239b8075eeb6fd5b727bfa65ebfbfa98a5ff93a5b45900d76097eafd2212b6c5e24e2de7a65db93ea6fc9fb9b9deef1344a7966884903c37e857a3b2"}],"ComponentSizeInKB":9812,"CompsigList":[],"FileList":["payload.json","SKHynix_PE10X0_U3_KPE10x0U3DK2.HPb","SKHynix_PE10X0_U3_KPE10x0U3DK2.xml"],"Name":"SKHynix_PE10X0_U3_KPE10x0U3DK2.fwpkg","SHA1Sum":"15ccce8c0894dbd08a55732cdd57cc266debc606","SHA256Sum":"a5cd31be4795d9cc76b6ff4665cd4c9cb2f78ec3d51a0fb026e0c09ce4fa7b5a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-304b594c4543","4d2340a5-304f-3330-3230-304b594c484c","4d2340a5-304f-3630-3430-304b594c484e","562340a5-304f-3130-3932-304b594c4542","562340a5-304f-3330-3834-304b594c4846","562340a5-304f-3730-3638-304b594c4848","562340a5-304f-3531-3336-304b594c484b"],"TypeOfChange":"1","Version":"HPK2"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600KYLEC, MO003200KYLHL, MO006400KYLHN, VO001920KYLEB, VO003840KYLHF, VO007680KYLHH and VO015360KYLHK","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"MO001600KYLEC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYLHL","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYLHN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYLEB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYLHF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYLHH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYLHK","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6d7b73a47b1a4c04ac1c05d6e7","SupportedDevices":["4d2340a5-304f-3130-3630-304b594c4543","4d2340a5-304f-3330-3230-304b594c484c","4d2340a5-304f-3630-3430-304b594c484e","562340a5-304f-3130-3932-304b594c4542","562340a5-304f-3330-3834-304b594c4846","562340a5-304f-3730-3638-304b594c4848","562340a5-304f-3531-3336-304b594c484b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]},{"OS":"VMware","Version":["8.0","9.0"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP070928.zip","SHA1Sum":"9964d765a1cfd648901210667e1f6a149f7c4e79","SHA256Sum":"25af35e08244731132bae11d3ceb3f1e2bff7c17b896fc39491c65873b10c392","SHA512Sum":"5edec19cb33b5ddc984cc2d8d4a110af3360a9f7fedaa9a6ce26071597c4f424a7442381e952814a22ac85f54eae758c86b17bef7c3a4d43499eb3018efc5c06"}],"ComponentSizeInKB":19131,"CompsigList":["CP070928.compsig"],"FileList":["/CP070928_BUILD_12.data","/CP070928.vmexe64","/CP070928.vmfile","/CP070928_VMw.zip","/CP070928.xml","/payload.json","/CP070928_VMw.zip/index.xml","/CP070928_VMw.zip/vendor-index.xml","/CP070928_VMw.zip/metadata.zip","/CP070928_VMw.zip/vib20/CP070928/HPE_bootbank_CP070928_HPD5.12-8.0.0.20613240.vib","/CP070928_VMw.zip/metadata.zip/vendor-index.xml","/CP070928_VMw.zip/metadata.zip/vmware.xml","/CP070928_VMw.zip/metadata.zip/vibs/CP070928--4962651068054852886.xml","/CP070928_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070928_HPD5.12-8.0.0.20613240.xml"],"Name":"CP070928.zip","SHA1Sum":"9964d765a1cfd648901210667e1f6a149f7c4e79","SHA256Sum":"25af35e08244731132bae11d3ceb3f1e2bff7c17b896fc39491c65873b10c392","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP070928","Version":"HPD5.12-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_26dfe3b1c0b845a1b44ad71f7c","SupportedDevices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","562340a5-304f-3531-3330-305058444256","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069723.exe","SHA1Sum":"d31b6e8c5a5e394c51f9ea8c801fa31ffa426595","SHA256Sum":"2c18f6089adac226fd70ebb4b364fe9bd1a459b6b27f1719dd4cb4f623e27117","SHA512Sum":"854e44acad93cf838c25c0d664f1749e4d658af3c5adf4a1e3f1fee6bd262b04352b71c22bf67bcfdc0a2418989496a7acecb94ace6d86a0f9919e13d88c2dc8"}],"ComponentSizeInKB":583,"CompsigList":["cp069723.compsig"],"FileList":["cp069723.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"Name":"cp069723.exe","SHA1Sum":"d31b6e8c5a5e394c51f9ea8c801fa31ffa426595","SHA256Sum":"2c18f6089adac226fd70ebb4b364fe9bd1a459b6b27f1719dd4cb4f623e27117","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.1.0"}],"InstallationDependency":{},"Name":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_62b2f5fb3af64069a682ab0c56","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","U46","U46","U47","U47","U50","I44","H08","H08","H10","A48","U39","U40","U50","H10","H10","U60","U61","U56","A43","A43","A42","A42","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Files":[{"Checksum":[{"Filename":"firmware-d6020_2.74-3.1_amd64.deb","SHA1Sum":"57637f6b2a10a61dc20c96222f4177d659bef727","SHA256Sum":"3b36ae370f784e0be89a171835c08ff8aba9b57f3a1f52a897b9fa3910868846","SHA512Sum":"7e032a942089db8b8763ec8b70f8f7fbef7d16f9a3433a2a95344e038c78146a7e1f5348dc6f6a0569c24e3f204371ceb027dd5d277889a1bfa8cc1642690b57"}],"ComponentSizeInKB":2298,"CompsigList":["firmware-d6020_2.74-3.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/CP072186.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072186.scexe","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072186.scexe"],"Name":"firmware-d6020_2.74-3.1_amd64.deb","SHA1Sum":"57637f6b2a10a61dc20c96222f4177d659bef727","SHA256Sum":"3b36ae370f784e0be89a171835c08ff8aba9b57f3a1f52a897b9fa3910868846","SoftwarePlatforms":[],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a5fe4aa499a84a9992876e6e59","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp052054.zip","SHA1Sum":"e2cb73ef1d2b4f19e1917c4e7ce10857d0ea5f64","SHA256Sum":"adaa13260e578d353ef947519b19e9ceb8510f63c87058ffa9a70584ee8e6986","SHA512Sum":"ee3f0c24e44f2ac16e97846b0eec32503921fc4f0b9bbd7e604a01b821959d463063da490dfaa194899a33cca8898c73adc373716ea6f79e26b892f5000d4ee1"}],"ComponentSizeInKB":32,"CompsigList":["cp052054.compsig"],"FileList":["/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip","/cp052054.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/vib20/nmst/MEL_bootbank_nmst_4.31.0.150-1OEM.801.0.0.21495797.vib","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/vibs/nmst--3413091292116279482.xml","/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797_24604171.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.31.0.150-1OEM.801.0.0.21495797.xml"],"Name":"cp052054.zip","SHA1Sum":"e2cb73ef1d2b4f19e1917c4e7ce10857d0ea5f64","SHA256Sum":"adaa13260e578d353ef947519b19e9ceb8510f63c87058ffa9a70584ee8e6986","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.1"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299","20a6e8e4-bf33-4c71-a6bf-d9ecd0345028"],"TypeOfChange":"1","Version":"2025.03.17","VibList":[{"Name":"nmst","Version":"4.31.0.150-1OEM.801.0.0.21495797"}]}],"InstallationDependency":{},"Name":"net-mst kernel module driver component for VMware ESXi 8.0 Update 3","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"nmst:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"Mellanox-NATIVE-NMST:4.31.0.150-1OEM.801.0.0.21495797","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_710b214b710b478db82f6f2cc0","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1007103c8020","a6b1a447-382a-5a4f-15b3-1007103c801f","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101315900221"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","I38","I41","I36","U34","U17","U34","P85","P89","U30","P89","U32","P89","U31","U20","U31","U20","U36","P86","U15","U15","U22","U41","P92","P99","U40","U21","U38","U38","I36","HPE Apollo 6500 Gen10 Plus (Chassis)","U19","U56","U61","U45","U25","U37","U24","U13","U12","U13","U14","U14","HPE Apollo sx40 Server","HPE Apollo pc40 Server","HPE Apollo kl20 Server","HPE Apollo am35 Server","I40","I43","I39","I40","I42","I37"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"cp068752.exe","SHA1Sum":"1f73738859667975bc361cfdb46e0aac4153153a","SHA256Sum":"f0fce030a655ee17f8d2365ad447e6394b0e746a1738d39e3afba5577d3dc2c3","SHA512Sum":"b62cb1f98076016571c958e4448a37a8a77a8f4d8c8dfeb4e20e303a812906f402471b266b562ddeb02b0441c6f0c31e2062ed4dee8f41a0b82f05bc95a4c445"}],"ComponentSizeInKB":3578,"CompsigList":["cp068752.compsig"],"FileList":["cp068752.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WBCQssssASFD2.rel"],"Name":"cp068752.exe","SHA1Sum":"1f73738859667975bc361cfdb46e0aac4153153a","SHA256Sum":"f0fce030a655ee17f8d2365ad447e6394b0e746a1738d39e3afba5577d3dc2c3","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_658a48b6cc0742208d5882f3f0","SupportedDevices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e","4d2340a5-304f-3531-3336-304a58424656","4d2340a5-304f-3730-3638-304a58424741"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"},{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070947.zip","SHA1Sum":"63e30c3dfbbdc88574e3122f01877847136f7a79","SHA256Sum":"58c948cc2f712dcc2ea75a7886bd1c780409d1d6828025f7686ffa28a8344ecc","SHA512Sum":"88ce71fe021f245b9cdd9e2f4b3e81a242e63f73b2c9b5c96fe16c16b1f433d978bcfb752df388e2315ea31d5e2ecf98f58eb0ecfaab4db7fa1e64f9a55ba92f"}],"ComponentSizeInKB":17652,"CompsigList":["CP070947.compsig"],"FileList":["/CP070947_BUILD_4.data","/CP070947.vmexe64","/CP070947.vmfile","/CP070947_VMw.zip","/CP070947.xml","/payload.json","/CP070947_VMw.zip/index.xml","/CP070947_VMw.zip/vendor-index.xml","/CP070947_VMw.zip/metadata.zip","/CP070947_VMw.zip/vib20/CP070947/HPE_bootbank_CP070947_HPD6.4-8.0.0.20613240.vib","/CP070947_VMw.zip/metadata.zip/vendor-index.xml","/CP070947_VMw.zip/metadata.zip/vmware.xml","/CP070947_VMw.zip/metadata.zip/vibs/CP070947--6523856759400546116.xml","/CP070947_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070947_HPD6.4-8.0.0.20613240.xml"],"Name":"CP070947.zip","SHA1Sum":"63e30c3dfbbdc88574e3122f01877847136f7a79","SHA256Sum":"58c948cc2f712dcc2ea75a7886bd1c780409d1d6828025f7686ffa28a8344ecc","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3330-304a57534a50"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070947","Version":"HPD6.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a3afed40b76a47d8ad43c473bf","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":240,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Files":[{"Checksum":[{"Filename":"CP070857.zip","SHA1Sum":"ffedf089cff457188cfa3c2c4d9915a2ca24f689","SHA256Sum":"86ff9e92a615888d8a1ef4f5569c43ac0d8b4f2400a14c1cb32049456b71dee1","SHA512Sum":"d6661caa9556520d098466a904c4ee0b243fb4229d2bef53740544f4b6a70b45eccdbd6347ed73bce54af111a98aad52db35dd2d89f6f7ed4b8e843ef66d8ab9"}],"ComponentSizeInKB":17171,"CompsigList":["CP070857.compsig"],"FileList":["/CP070857_BUILD_5.data","/CP070857.vmexe","/CP070857.vmexe64","/CP070857.vmfile","/CP070857_VMw.zip","/CP070857.xml","/payload.json","/CP070857_VMw.zip/index.xml","/CP070857_VMw.zip/vendor-index.xml","/CP070857_VMw.zip/metadata.zip","/CP070857_VMw.zip/vib20/CP070857/HPE_bootbank_CP070857_1.27.5-8.0.0.20613240.vib","/CP070857_VMw.zip/metadata.zip/vendor-index.xml","/CP070857_VMw.zip/metadata.zip/vmware.xml","/CP070857_VMw.zip/metadata.zip/vibs/CP070857--3744643468949072851.xml","/CP070857_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070857_1.27.5-8.0.0.20613240.xml"],"Name":"CP070857.zip","SHA1Sum":"ffedf089cff457188cfa3c2c4d9915a2ca24f689","SHA256Sum":"86ff9e92a615888d8a1ef4f5569c43ac0d8b4f2400a14c1cb32049456b71dee1","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27","VibList":[{"Name":"CP070857","Version":"1.27.5-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE Apollo 2000 Gen10 Plus Backplane Expander FW","PackageFormat":"","PerDeviceInstallTimeSeconds":240,"RebootRequired":"no","SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ec76c6ce1cac4a33ab5731ba66","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","8.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U47","U47","A46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-elx-lpfc-14.4.731.20-1.rhel9u7.x86_64.rpm","SHA1Sum":"35a82c57ceae8eff05147e87a97b5ee8542aaa96","SHA256Sum":"1b8e6481e3fcfd719b584671705191e1d97eaec8ac7d71de62208b10a4f60f59","SHA512Sum":"a9bf2c27a7e48e9c1bff9c4ba54b9385d1bfa3c4de143f40ef6b32facd3522b155ad5c454bf4e5161ebce340d13c0bb8f5c83d1ce857e7130ed29148bc433bb7"}],"ComponentSizeInKB":830,"CompsigList":["kmod-elx-lpfc-14.4.731.20-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/elx-lpfc","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"Name":"kmod-elx-lpfc-14.4.731.20-1.rhel9u7.x86_64.rpm","SHA1Sum":"35a82c57ceae8eff05147e87a97b5ee8542aaa96","SHA256Sum":"1b8e6481e3fcfd719b584671705191e1d97eaec8ac7d71de62208b10a4f60f59","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 9 Server Update 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c1cc044340dc471284b9556fd5","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U43_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072028.exe","SHA1Sum":"11a7f4fca9ace6730abcf2e78dbf873732e3a386","SHA256Sum":"d08f2db27f1401063d1b6d78e75ea4da7f778bedfcba9397d83297cef07899e7","SHA512Sum":"ac7747a34c49a8ea1a2c44cd3508326c61a8c0fadf251fa4d1bc6651feb02851abd38f16963c74e51b016341b0f848b6e99fad8685d0fda201221d4a4a98134d"}],"ComponentSizeInKB":8918,"CompsigList":["cp072028.compsig"],"FileList":["cp072028.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U43_3.76_05_28_2026.signed.flash"],"Name":"cp072028.exe","SHA1Sum":"11a7f4fca9ace6730abcf2e78dbf873732e3a386","SHA256Sum":"d08f2db27f1401063d1b6d78e75ea4da7f778bedfcba9397d83297cef07899e7","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 (U43) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bd88dbf49ea846a38b5c4e7173","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U43"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-852266afdf-HPD6-2.1.x86_64.rpm","SHA1Sum":"1ebfb22617bc4dfa29bc9d8fe385660f78e62222","SHA256Sum":"f919ff081a5d4dccf19206007cfe57312401a73fbf89ff041b186cbac33aa20f","SHA512Sum":"4acf16d2b6b94ce6bbf8cccbb20df08c3e7345024aeee191e43c9f557a3e96dc7ae7412e1060a3bd6fa373bc9868f60167393ca1eab50a3e10c45649124bb435"}],"ComponentSizeInKB":5002,"CompsigList":["firmware-hdd-852266afdf-HPD6-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/CP068866.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/TA15SEE0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068866.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068866.scexe"],"Name":"firmware-hdd-852266afdf-HPD6-2.1.x86_64.rpm","SHA1Sum":"1ebfb22617bc4dfa29bc9d8fe385660f78e62222","SHA256Sum":"f919ff081a5d4dccf19206007cfe57312401a73fbf89ff041b186cbac33aa20f","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_56f020a0165144c8989c5eba4a","SupportedDevices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3496cc4743_0HPG3-2.1_amd64.deb","SHA1Sum":"cb4e3f98dcdf4665e2e196303144caa44710b599","SHA256Sum":"33fe1c148d78cfdffee1d2bdc4de4736ad4c3cfdbde0c56bdbfc68404b0e3a3e","SHA512Sum":"3b57325be2356e467ab6cba9791d26cfcf83ceccb583d476ad39973ae017759c4680465c75f9fd58adccb44ce9509539f762c08dcd3045fc7e002fc10ea2d806"}],"ComponentSizeInKB":4230,"CompsigList":["firmware-hdd-3496cc4743_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/CP071770.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/SLONGSPKETG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071770.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071770.scexe"],"Name":"firmware-hdd-3496cc4743_0HPG3-2.1_amd64.deb","SHA1Sum":"cb4e3f98dcdf4665e2e196303144caa44710b599","SHA256Sum":"33fe1c148d78cfdffee1d2bdc4de4736ad4c3cfdbde0c56bdbfc68404b0e3a3e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MB018000GXMTK and MB020000GXMTQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cc927d993d3e41a2ae84949c49","SupportedDevices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-faf39e0ff7_0HPD9-2.1_amd64.deb","SHA1Sum":"cd91220ebb47cb449bf0c950d120cdce4652e1d3","SHA256Sum":"df89c5dbf765b0696c4c4588515408bb17b8a4008dbd755884a9775fa9d9d734","SHA512Sum":"9f179313a598c16ba4022cc744a34acce635b3014bc5bc2ec40ba00fcd35fcf0515f1d39e811fec2eda14588542813bcb9a3144484f26afe84c946743dc0a1d3"}],"ComponentSizeInKB":3549,"CompsigList":["firmware-hdd-faf39e0ff7_0HPD9-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/CP071732.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/TAMG06scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071732.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071732.scexe"],"Name":"firmware-hdd-faf39e0ff7_0HPD9-2.1_amd64.deb","SHA1Sum":"cd91220ebb47cb449bf0c950d120cdce4652e1d3","SHA256Sum":"df89c5dbf765b0696c4c4588515408bb17b8a4008dbd755884a9775fa9d9d734","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd30be672e754b93b9db2577d7","SupportedDevices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Files":[{"Checksum":[{"Filename":"cp067914.exe","SHA1Sum":"77ab5498ec7d3ab143561e871d5d1f51cbaaeafb","SHA256Sum":"53c2faf21729c4da78199d8771a62fb9e794a9590231cf3f7a99e98533233260","SHA512Sum":"f1be145743e997726cfa3584373f4c946e40b3af1e619d7d045bcfb0f4f50340713f47ba7634203de9b93ebed16ec00919d5cc401b9b1b94923ad3804ccd2a82"}],"ComponentSizeInKB":3661,"CompsigList":["cp067914.compsig"],"FileList":["Capitola-Release-1.27.bin.fw","cp067914.xml","cpqsetup.exe","payload.json","setup.dll"],"Name":"cp067914.exe","SHA1Sum":"77ab5498ec7d3ab143561e871d5d1f51cbaaeafb","SHA256Sum":"53c2faf21729c4da78199d8771a62fb9e794a9590231cf3f7a99e98533233260","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE Apollo 2000 Gen10 Plus Backplane Expander FW","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5bd325460cd446faaf9c162a70","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U47","U47","A46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SPSGen10Plus_04.04.04.926.signed.bin","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.926"}]},"Files":[{"Checksum":[{"Filename":"SPSGen10Plus_04.04.04.926.fwpkg","SHA1Sum":"389c1af21a28be0bfb0628037bed7d24c3f11ce0","SHA256Sum":"e059f18b37587bbec54dfb3e31f5fa5459ef5ce2827a2329f752b8ebbf1f8607","SHA512Sum":"2cc272d837636776160ba2ec41384ddddfa2adf545b979a5eaf9ad85d7d12b1c66b16ba3b3f80c6cd0284cdc0762f93992b11e6fffcb73dff72b33008c4b9b9f"}],"ComponentSizeInKB":8214,"CompsigList":[],"FileList":["payload.json","SPSGen10Plus_04.04.04.926.signed.bin","SPSGen10Plus_04.04.04.926.xml"],"Name":"SPSGen10Plus_04.04.04.926.fwpkg","SHA1Sum":"389c1af21a28be0bfb0628037bed7d24c3f11ce0","SHA256Sum":"e059f18b37587bbec54dfb3e31f5fa5459ef5ce2827a2329f752b8ebbf1f8607","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.926"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Plus Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8f1a540a0b8a4feca80cf12af7","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U56","H10","H10","H10","U36","U46"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Files":[{"Checksum":[{"Filename":"cp067916.exe","SHA1Sum":"ab45da455fc8605979d9faef8470b42d9b6f2246","SHA256Sum":"5bd3d79c3cf13c93a02403ea31857860080def96250cf967ba9e04b9050e8471","SHA512Sum":"be688a324edd9c335ef4f75fc80521c0a46e5474c9247e7b2183393e1764d48e16018b7e760f82539f53658e5aa48c98e99787b4a6873780f06772a1c02a2f21"}],"ComponentSizeInKB":3542,"CompsigList":["cp067916.compsig"],"FileList":["cp067916.xml","cpqsetup.exe","firmware-Signed-5.15-build-000.bin.fw","payload.json","setup.dll"],"Name":"cp067916.exe","SHA1Sum":"ab45da455fc8605979d9faef8470b42d9b6f2246","SHA256Sum":"5bd3d79c3cf13c93a02403ea31857860080def96250cf967ba9e04b9050e8471","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ec7574dfdf54b5b857e9c488e","SupportedDevices":["422340a5-3939-4644-4237-342d07f65795"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A40","U30","P89","U41","A42","U46","U46","A43","A42","A43","A43","A42","U31"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Files":[{"Checksum":[{"Filename":"cp068664.exe","SHA1Sum":"aca88b0a26fc62634eac587eac2ae310f73622bb","SHA256Sum":"62c04c5d2325ef39b349f4b51f2d77da6d1888819c33b5707ca20796515d8b88","SHA512Sum":"c218a0a64a5590c1510e68842e4f1aca67a9687e85db5dfd4a49798741299d8db99ce3a714227e22d91e96aea31d4b4a53147c99066b0e40e67cb8a58faf1bfb"}],"ComponentSizeInKB":3927,"CompsigList":["cp068664.compsig"],"FileList":["cp068664.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNETG8.rel","setup.dll"],"Name":"cp068664.exe","SHA1Sum":"aca88b0a26fc62634eac587eac2ae310f73622bb","SHA256Sum":"62c04c5d2325ef39b349f4b51f2d77da6d1888819c33b5707ca20796515d8b88","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWWQU and MB006000GWWQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e9dad618e5094f738b2218775c","SupportedDevices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-1f19a4a64d-5.15-6.1.x86_64.rpm","SHA1Sum":"741ed5eccaa8a8a04b8b81bc05affbc222d63029","SHA256Sum":"eff9d7569abed1473c11bb8b0a5ee80afa685f2228b11178920a18d9e8a7048c","SHA512Sum":"ae0bedf857e87a6bb34c3eb78670687509a42dd6f599177b5bdc23152ab5859835b8c6feaacafa656f7b2f16ebac42804ca4e96704b6053327d171dd7725adab"}],"ComponentSizeInKB":5297,"CompsigList":["firmware-smartarray-1f19a4a64d-5.15-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/CP068826.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/firmware-Signed-5.15-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068826.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068826.scexe"],"Name":"firmware-smartarray-1f19a4a64d-5.15-6.1.x86_64.rpm","SHA1Sum":"741ed5eccaa8a8a04b8b81bc05affbc222d63029","SHA256Sum":"eff9d7569abed1473c11bb8b0a5ee80afa685f2228b11178920a18d9e8a7048c","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Supplemental Update / Online ROM Flash Component for Linux (x64) – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_00fabe6608db428a9aa80c4965","SupportedDevices":["422340a5-3939-4644-4237-342d07f65795"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A40","U30","P89","U41","A42","U46","U46","A43","A42","A43","A43","A42","U31"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"cp068644.exe","SHA1Sum":"6a3f8647269e8a34502ee7ac5da6d48540934420","SHA256Sum":"ffb18b70bb68d5007cf1774f6b0b6f23d31a2b24903a3b6974f215150b51655f","SHA512Sum":"0ace767d509d77c678674aaf1f534df74089aafb16a062cb6cf67704ecb70463812349d4e422cbdab799d2a853a78f4d6e45d257d50d572fc1ebf02b559a35b2"}],"ComponentSizeInKB":3163,"CompsigList":["cp068644.compsig"],"FileList":["cp068644.xml","cpqsetup.exe","KAPM5ALSHPDB.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068644.exe","SHA1Sum":"6a3f8647269e8a34502ee7ac5da6d48540934420","SHA256Sum":"ffb18b70bb68d5007cf1774f6b0b6f23d31a2b24903a3b6974f215150b51655f","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2ba38c58637a46b988c479eb00","SupportedDevices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"tg3-kmp-default-3.140b_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm","SHA1Sum":"b7c32ea04391ebfa3195eb935c3c1e1982ecb3db","SHA256Sum":"3cc64cb79f24a1ff64fe3fe4e11546f06d712e39f50fc0ade0c09a2397d538a2","SHA512Sum":"3e307ad6d9c2d6c48c84304140b7a49ab62795f9274348d8b8815ba2fe9ac0737a14a6338cff8932da5912070d144f33c659ef6c6b149c33dcb2b9daa09678df"}],"ComponentSizeInKB":129,"CompsigList":["tg3-kmp-default-3.140b_k6.4.0_150600.21-2.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"Name":"tg3-kmp-default-3.140b_k6.4.0_150600.21-2.sles15sp6.x86_64.rpm","SHA1Sum":"b7c32ea04391ebfa3195eb935c3c1e1982ecb3db","SHA256Sum":"3cc64cb79f24a1ff64fe3fe4e11546f06d712e39f50fc0ade0c09a2397d538a2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.140b-2"},{"Checksum":[{"Filename":"tg3-kmp-default-3.140b_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm","SHA1Sum":"537aa71302ee3f692aafbdcf50dcc3a2949456b3","SHA256Sum":"964ec49128dffcc8266e11691de0ee272848301c9d9ff164f576ec2a3a2ffd56","SHA512Sum":"b6e68b9e31f4ae85a8f8d69131450d9a988f5fb7e0d1ded70fa8ce62979a69648102a018c7b9a00bacf95c029df4ff79566f4f4b19d2879d29c3d928cfeac280"}],"ComponentSizeInKB":131,"CompsigList":["tg3-kmp-default-3.140b_k6.4.0_150700.51-2.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"Name":"tg3-kmp-default-3.140b_k6.4.0_150700.51-2.sles15sp7.x86_64.rpm","SHA1Sum":"537aa71302ee3f692aafbdcf50dcc3a2949456b3","SHA256Sum":"964ec49128dffcc8266e11691de0ee272848301c9d9ff164f576ec2a3a2ffd56","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.140b-2"}],"InstallationDependency":{},"Name":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_489e6ca1dfb34e93ae41e91303","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","02020001","03020101","A42","U56","U61","U60","U58","U58","03030202","U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U39","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB NDR200 1p OSFP MCX75310AAS Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.signed","InstallDurationSec":900,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-102115b30074","Version":"28.49.1014"}]},"Files":[{"Checksum":[{"Filename":"28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.fwpkg","SHA1Sum":"f181907f5cc590d807edeff2d516a1bb08b15ea4","SHA256Sum":"290b0dc84801ab9b092c2e51756a0795046128344d57c1220daa67a0a11ccedd","SHA512Sum":"2441a1f469338ef4894f7b68c7409e4c503872ab81d32277c10b5eaaf506d8945501799db3c4d7ae241f4e72c9729be04f0995f0fb255e8237d2c8356189dace"}],"ComponentSizeInKB":9412,"CompsigList":[],"FileList":["28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.signed","28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.xml","payload.json"],"Name":"28_49_1014-MCX75310AAS-HEAT_HPE_Ax.pldm.fwpkg","SHA1Sum":"f181907f5cc590d807edeff2d516a1bb08b15ea4","SHA256Sum":"290b0dc84801ab9b092c2e51756a0795046128344d57c1220daa67a0a11ccedd","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-102115b30074"],"TypeOfChange":"1","Version":"28.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B21 and P45642-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":900,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX75310AAS-HEAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4d81d839f3a64f16a96d99e796","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30074"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","U63","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069722.exe","SHA1Sum":"7721cc32a14c1b549e319c103e1b429d066fe5ae","SHA256Sum":"97a1759cfc9ae1322f870c31450e8e32333feedd2d53947745f12c2ead3f4241","SHA512Sum":"23783d34ada6f3c24a19105f151d43570b35740af5b8ab09696563e2d24346a51e2466d6ae7c811edda8c3599e04aeac1ea16b852f9ec5bde8af77d58f4412a6"}],"ComponentSizeInKB":566,"CompsigList":["cp069722.compsig"],"FileList":["cp069722.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"Name":"cp069722.exe","SHA1Sum":"7721cc32a14c1b549e319c103e1b429d066fe5ae","SHA256Sum":"97a1759cfc9ae1322f870c31450e8e32333feedd2d53947745f12c2ead3f4241","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.1.0"}],"InstallationDependency":{},"Name":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_60c84d67122f4120814e871a3b","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-33071590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","I44","U46","U46","U47","U47","U50","H08","H08","H10","H10","H10","U60","U61","U56","A42","A43","A43","A42","A48","U50","U39","U40","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3438-304759434e54","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3936-304759434e50","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3130-3932-304759434e46","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3330-3834-304759434e51","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3234-304759434e55","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3438-304759434e48","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3936-304759434e4b","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-304759434e4c","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3330-3834-304759434e4e","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3730-3638-304759434e45","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3234-304758505154","Version":"HPG4"},{"DeviceName":"Solidigm-S4X20-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_S4X20_4IYYHPG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304758505155","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"Solidigm_S4X20_4IYYHPG4.fwpkg","SHA1Sum":"f1041efa62e599fbc3fc7927ea2e7f8c437aba16","SHA256Sum":"1f73fa1d0c76689516d832aef9c140a9920809276addd57dad0495375425afc1","SHA512Sum":"65b5d672dc5e33dba4d4431773c20352bb4d3ca60a3ed9951ef4dafb253a0d99dfe18ba04d5085db638231484e56df7860ed3f463d8f24b9504482da9770216d"}],"ComponentSizeInKB":1459,"CompsigList":[],"FileList":["payload.json","Solidigm_S4X20_4IYYHPG4.HPb","Solidigm_S4X20_4IYYHPG4.xml"],"Name":"Solidigm_S4X20_4IYYHPG4.fwpkg","SHA1Sum":"f1041efa62e599fbc3fc7927ea2e7f8c437aba16","SHA256Sum":"1f73fa1d0c76689516d832aef9c140a9920809276addd57dad0495375425afc1","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-304759434e54","4d2340a5-304b-3030-3936-304759434e50","4d2340a5-304b-3130-3932-304759434e46","4d2340a5-304b-3330-3834-304759434e51","562340a5-304b-3030-3234-304759434e55","562340a5-304b-3030-3438-304759434e48","562340a5-304b-3030-3936-304759434e4b","562340a5-304b-3130-3932-304759434e4c","562340a5-304b-3330-3834-304759434e4e","562340a5-304b-3730-3638-304759434e45","562340a5-3052-3030-3234-304758505154","562340a5-3052-3030-3438-304758505155"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MK000480GYCNT ,MK000960GYCNP ,MK001920GYCNF ,MK003840GYCNQ ,VK000240GYCNU ,VK000480GYCNH ,VK000960GYCNK ,VK001920GYCNL ,VK003840GYCNN ,VK007680GYCNE ,VR000240GXPQT and VR000480GXPQU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GYCNT","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK000960GYCNP","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK001920GYCNF","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MK003840GYCNQ","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000240GYCNU","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000480GYCNH","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK000960GYCNK","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK001920GYCNL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK003840GYCNN","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VK007680GYCNE","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VR000240GXPQT","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"VR000480GXPQU","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8ae279136d1146d9a07e0ced51","SupportedDevices":["4d2340a5-304b-3030-3438-304759434e54","4d2340a5-304b-3030-3936-304759434e50","4d2340a5-304b-3130-3932-304759434e46","4d2340a5-304b-3330-3834-304759434e51","562340a5-304b-3030-3234-304759434e55","562340a5-304b-3030-3438-304759434e48","562340a5-304b-3030-3936-304759434e4b","562340a5-304b-3130-3932-304759434e4c","562340a5-304b-3330-3834-304759434e4e","562340a5-304b-3730-3638-304759434e45","562340a5-3052-3030-3234-304758505154","562340a5-3052-3030-3438-304758505155"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A48_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A48_4.04_04_02_2026.fwpkg","SHA1Sum":"36395ed47a36afd8a7efb7f655d1d6ed5596a1c7","SHA256Sum":"0aad28545bbe7dadf732bf045095116b15b23de38428f863ac7e4f34fc08b4da","SHA512Sum":"90cbeb45f32d6871d919b16b8c04ec81459a458d37150c91cc093623f188634e2a71ba34de05f01fca61de8844236a2588687d996252c6609e461b24f60a17db"}],"ComponentSizeInKB":32808,"CompsigList":[],"FileList":["A48_4.04_04_02_2026.signed.flash","A48_4.04_04_02_2026.xml","payload.json"],"Name":"A48_4.04_04_02_2026.fwpkg","SHA1Sum":"36395ed47a36afd8a7efb7f655d1d6ed5596a1c7","SHA256Sum":"0aad28545bbe7dadf732bf045095116b15b23de38428f863ac7e4f34fc08b4da","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_31ecb92b742e40af8dee4d261b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U39_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073166.exe","SHA1Sum":"f1ae8238305bb8a50a752e7e1fd902e872247958","SHA256Sum":"7ac172412c96a339f0aa820f2639108387c76e8d965845b6346b41fa3bbd1bd5","SHA512Sum":"61db803af2fc4dc7375b71e867b4a5297aa2363f4cb6fc054936738af6463552ed1715c17de4a4e0adfffea0de475a7af00c3c4edd8b4a87381953cc4ee3e5e2"}],"ComponentSizeInKB":11434,"CompsigList":["cp073166.compsig"],"FileList":["cp073166.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U39_3.70_08_19_2026.signed.flash"],"Name":"cp073166.exe","SHA1Sum":"f1ae8238305bb8a50a752e7e1fd902e872247958","SHA256Sum":"7ac172412c96a339f0aa820f2639108387c76e8d965845b6346b41fa3bbd1bd5","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8838686af55b4835a981fb04f3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U39","U39"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp066052.zip","SHA1Sum":"a7dd979017be67ed61120299c256e639f6e99901","SHA256Sum":"378907c9d3ccff4bc35a6bc7124b047ab90c517a90d275aaffeb5f3b493d3894","SHA512Sum":"b07ea3c41424b9dfedc83bb77b96fc3215150d650111bfdbc21083c8856c00943a3c5d2facbe0f07892ccdc58be9ab535ec1e1edc48b84422d234c7dc0506fbf"}],"ComponentSizeInKB":138,"CompsigList":["cp066052.compsig"],"FileList":["/cp066052.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/vib20/igbn/INT_bootbank_igbn_1.12.2.0-1OEM.800.1.0.20613240.vib","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vmware.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/vibs/igbn--4585876958502114762.xml","/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240_24584378.zip/metadata.zip/bulletins/Intel-igbn_1.12.2.0-1OEM.800.1.0.20613240.xml"],"Name":"cp066052.zip","SHA1Sum":"a7dd979017be67ed61120299c256e639f6e99901","SHA256Sum":"378907c9d3ccff4bc35a6bc7124b047ab90c517a90d275aaffeb5f3b493d3894","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2025.05.00","VibList":[{"Name":"igbn","Version":"1.12.2.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE Intel igbn Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.12.2.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_91eedfc8544c413bbd1e5e7e2f","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","A58","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b59445a4b","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b59445a52","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b59445a54","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b59445a55","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b59445a48","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3533-364b59445a51","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b59445a4c","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b59445a4e","Version":"HPK6"},{"DeviceName":"Micron-7500-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7500_M7500ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b59445a50","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"Micron_7500_M7500ALLHPK6.fwpkg","SHA1Sum":"18ba68fc65ddb89dea4a3d13bd3fb4eb9f5b2b62","SHA256Sum":"72971fa3e44ffaae8a7d590fd3226c4f1a2532e2f815b6ceb32199bfcebab5d1","SHA512Sum":"a4073cd4499900e720746ee01280b488ea36cafe782d3f0d60373943f0356a4154f986a24bee250419419e2ae5f324190673e15f0c643c54905b6159062c6ab6"}],"ComponentSizeInKB":2206,"CompsigList":[],"FileList":["Micron_7500_M7500ALLHPK6.HPb","Micron_7500_M7500ALLHPK6.xml","payload.json"],"Name":"Micron_7500_M7500ALLHPK6.fwpkg","SHA1Sum":"18ba68fc65ddb89dea4a3d13bd3fb4eb9f5b2b62","SHA256Sum":"72971fa3e44ffaae8a7d590fd3226c4f1a2532e2f815b6ceb32199bfcebab5d1","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304b59445a4b","4d2340a5-304f-3130-3630-304b59445a52","4d2340a5-304f-3330-3230-304b59445a54","4d2340a5-304f-3630-3430-304b59445a55","562340a5-304f-3030-3936-304b59445a48","562340a5-304f-3130-3533-364b59445a51","562340a5-304f-3130-3932-304b59445a4c","562340a5-304f-3330-3834-304b59445a4e","562340a5-304f-3730-3638-304b59445a50"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MO000800KYDZK, MO001600KYDZR, MO003200KYDZT, MO006400KYDZU, VO000960KYDZH, VO001920KYDZL, VO003840KYDZN, VO001536KYDZQ and VO007680KYDZP","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800KYDZK","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KYDZR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYDZT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYDZU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KYDZH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYDZL","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYDZN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYDZP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001536KYDZQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fc0c2a18b79a47bdbb56ae5857","SupportedDevices":["4d2340a5-304f-3630-3430-304b59445a55","4d2340a5-304f-3330-3230-304b59445a54","4d2340a5-304f-3130-3630-304b59445a52","4d2340a5-304f-3030-3830-304b59445a4b","562340a5-304f-3730-3638-304b59445a50","562340a5-304f-3330-3834-304b59445a4e","562340a5-304f-3130-3932-304b59445a4c","562340a5-304f-3030-3936-304b59445a48","562340a5-304f-3130-3533-364b59445a51"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U33_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073143.exe","SHA1Sum":"dab61f2d52234534f7e42118a04015dd9396e5a3","SHA256Sum":"2d537b6c93e1024c9b2ef1e05a5332697bec3958ee1f769bbf13eb416a4f9095","SHA512Sum":"d416bf013a6c36cd580330437919a726a5b52d621dd66f9493cbaeee35835853769384e8112e5056f42f74e51ad903e32ff80e7dad573704f59582b38ed6a7e0"}],"ComponentSizeInKB":11173,"CompsigList":["cp073143.compsig"],"FileList":["cp073143.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U33_3.70_08_19_2026.signed.flash"],"Name":"cp073143.exe","SHA1Sum":"dab61f2d52234534f7e42118a04015dd9396e5a3","SHA256Sum":"2d537b6c93e1024c9b2ef1e05a5332697bec3958ee1f769bbf13eb416a4f9095","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML110 Gen10 (U33) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dc7086e707854e8f91bc780d75","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U33"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U37_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073168.exe","SHA1Sum":"ffdef2bc57b790276168af00a42a81fdec09fec6","SHA256Sum":"64685fe2611ad60616860a4728b4d28103005bec523833836e03d6c2fbc37fa9","SHA512Sum":"0d828dd35a1e37cb9aac169fa2c6a473ff74e1b85a7d685298e2dcb4f85660eeebca505bcb0fbcf5f9d0c8312d07eccfa75397b38e1868476aa3b80cec3d1739"}],"ComponentSizeInKB":11228,"CompsigList":["cp073168.compsig"],"FileList":["cp073168.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U37_3.70_08_19_2026.signed.flash"],"Name":"cp073168.exe","SHA1Sum":"ffdef2bc57b790276168af00a42a81fdec09fec6","SHA256Sum":"64685fe2611ad60616860a4728b4d28103005bec523833836e03d6c2fbc37fa9","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL230k Gen10 (U37) Server","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_86f3d043687f4e79892026fe59","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U37"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Power Management","ComponentLocation":"","CompsigCount":0,"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Files":[{"Checksum":[{"Filename":"PICGen10-1.1.4-1.fwpkg","SHA1Sum":"903f3790b3a941f18adc03dad7ef78e5e7e56999","SHA256Sum":"631ef83cfa8ff875fa67ad904dadf0750d46dcf885c52143bb677db36e86db7e","SHA512Sum":"3bf5c5d18dfebfe42234dd1a7ff9b091b3e55c7a36c9bbb6c960ae6523f7934a552ff3f09739d7fc5f2f99687671f7ca08fbac009b30ff45c26be56127e57c3b"}],"ComponentSizeInKB":147,"CompsigList":[],"FileList":["payload.json","PICGen10-1.1.4-1.xml","PICGen10_v1.1.4_hdr.signed.hex"],"Name":"PICGen10-1.1.4-1.fwpkg","SHA1Sum":"903f3790b3a941f18adc03dad7ef78e5e7e56999","SHA256Sum":"631ef83cfa8ff875fa67ad904dadf0750d46dcf885c52143bb677db36e86db7e","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_84e80a3fb2e04c93b20e3b09f3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.0","6.5","6.7","7.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A43","A42","A43","A42","A42","A43","A41","A40","U34","U34","U46","U30","U46","U32","U31","U31","U36","U43","U60","U41","U33","U61","U44","U50","U39","U50","U56","U46","U65"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"CP070927.zip","SHA1Sum":"78cce2149044a5d286c5252d4d0ede11465655b7","SHA256Sum":"39fd25460ec06238c3355f07ee48c408d141f7adf3876435cffe36fda4c8f3cb","SHA512Sum":"30d7c32cf17d4a434e8fb5d946d315b6db7a54f58fa5d08e0402bd6c2144e6e3c0a899064e23e33c36b2fced7a59cb3758aaae47e0d4cd7c421e35a50c5563cd"}],"ComponentSizeInKB":18578,"CompsigList":["CP070927.compsig"],"FileList":["/CP070927_BUILD_9.data","/CP070927.vmexe64","/CP070927.vmfile","/CP070927_VMw.zip","/CP070927.xml","/payload.json","/CP070927_VMw.zip/index.xml","/CP070927_VMw.zip/vendor-index.xml","/CP070927_VMw.zip/metadata.zip","/CP070927_VMw.zip/vib20/CP070927/HPE_bootbank_CP070927_HPD8.9-8.0.0.20613240.vib","/CP070927_VMw.zip/metadata.zip/vendor-index.xml","/CP070927_VMw.zip/metadata.zip/vmware.xml","/CP070927_VMw.zip/metadata.zip/vibs/CP070927-8422540308775341791.xml","/CP070927_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070927_HPD8.9-8.0.0.20613240.xml"],"Name":"CP070927.zip","SHA1Sum":"78cce2149044a5d286c5252d4d0ede11465655b7","SHA256Sum":"39fd25460ec06238c3355f07ee48c408d141f7adf3876435cffe36fda4c8f3cb","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP070927","Version":"HPD8.9-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5087d4ec9b6646b484bd1f761c","SupportedDevices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mft-4.36.0-147.sles16sp0.x86_64.rpm","SHA1Sum":"0a220ef5bd7ab474d9f6f9ccbd2d9a28eb30e077","SHA256Sum":"eaaf676cd5cf61e1535fa43818c620283af500a8b097cd56334379f40bf3b93e","SHA512Sum":"bbb5a78e59cfee58303c044f64eea193933ed85cdb814e86b2b45a3673fb88d75c71ebe391dde7cba8212e24a60287f843c0e1e97c2828ae9003d5768f95e287"}],"ComponentSizeInKB":29836,"CompsigList":["mft-4.36.0-147.sles16sp0.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.sles16sp0.x86_64.rpm","SHA1Sum":"0a220ef5bd7ab474d9f6f9ccbd2d9a28eb30e077","SHA256Sum":"eaaf676cd5cf61e1535fa43818c620283af500a8b097cd56334379f40bf3b93e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"kernel-mft-mlnx-kmp-default-4.36.0_k6.12.0_160000.5-147.1.sles16sp0.x86_64.rpm","SHA1Sum":"a301c6f78bbe8a4e7859b1498cf2b84aef527131","SHA256Sum":"0a8954be6aced62605ad64e1e542a69310208a2a63fe6cf57e3f060d787c299c","SHA512Sum":"1e962f8f90c63098987efa55d31f5ddf5c85808218cf32938b7229bac454fb057e402190744a6210b8de7d830847551c075d63fea30ae19d596750708af6cc79"}],"ComponentSizeInKB":83,"CompsigList":["kernel-mft-mlnx-kmp-default-4.36.0_k6.12.0_160000.5-147.1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/mst_pci.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"Name":"kernel-mft-mlnx-kmp-default-4.36.0_k6.12.0_160000.5-147.1.sles16sp0.x86_64.rpm","SHA1Sum":"a301c6f78bbe8a4e7859b1498cf2b84aef527131","SHA256Sum":"0a8954be6aced62605ad64e1e542a69310208a2a63fe6cf57e3f060d787c299c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 16 SP0 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f399b0cc48634f37902d482c36","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","03030201","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM897.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9475583fb5-HPG1-6.1.x86_64.rpm","SHA1Sum":"36c9a3829f935c8161f3e1c0652d6dd08489765b","SHA256Sum":"c6bbc1f54ca33e16d38495cfacd8f9fcbb7ae4305aaa1298f8e83bb8e6373034","SHA512Sum":"3d5e0f91051b8022a1b4c73c344a3e236244dbfcbbeeccde24f55639da3f913b4b5b14be08f381aefd4ed12d2ab976c771be9b6f65814f7f678d8b34c5f4b3e1"}],"ComponentSizeInKB":6620,"CompsigList":["firmware-hdd-9475583fb5-HPG1-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/CP068917.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/HPG1_PM897.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068917.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068917.scexe"],"Name":"firmware-hdd-9475583fb5-HPG1-6.1.x86_64.rpm","SHA1Sum":"36c9a3829f935c8161f3e1c0652d6dd08489765b","SHA256Sum":"c6bbc1f54ca33e16d38495cfacd8f9fcbb7ae4305aaa1298f8e83bb8e6373034","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_09fad2ae6ae840ae99f4ef3701","SupportedDevices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U39_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U39_3.70_08_19_2026.fwpkg","SHA1Sum":"39e36b99d091e6c6413ec40d89aa76d4af4462c1","SHA256Sum":"102c5a5637dc99e9f0ee9e8c5011ab4f2f7a27f4e459c9af98cd402ff12d1657","SHA512Sum":"c56f25654c41b6f018960b5e3e1b6763e7ea1aea1aa86c16b8dfc930a58fc12c8e30275d7fe58746c570eb2ed360e64530265a1459c77c6200afb93fceb1f995"}],"ComponentSizeInKB":32824,"CompsigList":[],"FileList":["payload.json","U39_3.70_08_19_2026.signed.flash","U39_3.70_08_19_2026.xml"],"Name":"U39_3.70_08_19_2026.fwpkg","SHA1Sum":"39e36b99d091e6c6413ec40d89aa76d4af4462c1","SHA256Sum":"102c5a5637dc99e9f0ee9e8c5011ab4f2f7a27f4e459c9af98cd402ff12d1657","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5ee3c71d23364d1493a6836eee","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U39","U39"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp064345.zip","SHA1Sum":"e670856774f0820f8a1650db262f684097d5324f","SHA256Sum":"9f118789dc8e6c1acba834040de98b4b32a09df5d6c9bf47b3832104e3da4d27","SHA512Sum":"7ca5575c6ceb44d4cfa0b3f2b0c2b59237288dd73a2a8fa25e32d6f6ee3ab8c08317222860d545830a6ebb13fa06ef37c095869238084fdf676ac1fcc8e6e2fb"}],"ComponentSizeInKB":1487,"CompsigList":["cp064345.compsig"],"FileList":["/cp064345.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"Name":"cp064345.zip","SHA1Sum":"e670856774f0820f8a1650db262f684097d5324f","SHA256Sum":"9f118789dc8e6c1acba834040de98b4b32a09df5d6c9bf47b3832104e3da4d27","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_efd45025f131446c8a82a2b5fb","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069566.exe","SHA1Sum":"cdac6f896d70ceff4ebf7a247351a78c2bbbb644","SHA256Sum":"08e077a81acaef192ffd75e7b9a6d7d4f9aa39ac77c4103e0d0a54f6ad188e71","SHA512Sum":"aee99f6f73710f199c132198804bca6eb3879cf0cae93ca7b680978a630f991abb1f3a5b2b83bcca12a6429981383866adc0a4e5e9258fd10e7f5c8ac36a0ffe"}],"ComponentSizeInKB":3492,"CompsigList":["cp069566.compsig"],"FileList":["cp069566.xml","cpqsetup.exe","cp_data.xml","install.xml","qefcdo.sys","qefcdo_release.txt","qefcoe.cat","qefcoe.inf","qefcoe.sys","qefcoeco.dll","qefcoe_release.txt","qeiscdo.sys","qeiscdo_release.txt","qend.cat","qend.inf","qend.man","qenda.sys","qeois.cat","qeois.inf","qeois.sys","qeoisco.dll","qeois_release.txt","qevbd.cat","qevbd.inf","qevbda.sys","QLInstaller.dll","slipstream.zip"],"Name":"cp069566.exe","SHA1Sum":"cdac6f896d70ceff4ebf7a247351a78c2bbbb644","SHA256Sum":"08e077a81acaef192ffd75e7b9a6d7d4f9aa39ac77c4103e0d0a54f6ad188e71","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"TypeOfChange":"1","Version":"8.72.21.0"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"qevbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9a4d9987d9a0415894252fe50a","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-8090159002bf","a6b1a447-382a-5a4f-1077-8090159002be","a6b1a447-382a-5a4f-1077-8090159002c0","a6b1a447-382a-5a4f-1077-80801590021f","a6b1a447-382a-5a4f-1077-80841590021f","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f","a6b1a447-382a-5a4f-1077-80801590021a","a6b1a447-382a-5a4f-1077-80801590021b","a6b1a447-382a-5a4f-1077-80841590021a","a6b1a447-382a-5a4f-1077-80841590021b","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-80901590021a","a6b1a447-382a-5a4f-1077-80901590021b","a6b1a447-382a-5a4f-1077-80901590021b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Files":[{"Checksum":[{"Filename":"CP070936.zip","SHA1Sum":"aa7030601a5710b277fbf9811b367a67ff81757e","SHA256Sum":"4d5aaa63f1146ea8641b00586286ec99a42581ba09d23c2d6f875aacd6afd8c7","SHA512Sum":"f44e47bfc9dd27f1c7b0b5ff652f7fe961b09add19689b6896adeef7f6b5ea98b9659dcb0c3e94f361dc5498b72e5df06f0cb1c8b6d584697c21ad2fb97482db"}],"ComponentSizeInKB":19669,"CompsigList":["CP070936.compsig"],"FileList":["/CP070936_BUILD_4.data","/CP070936.vmexe64","/CP070936.vmfile","/CP070936_VMw.zip","/CP070936.xml","/payload.json","/CP070936_VMw.zip/index.xml","/CP070936_VMw.zip/vendor-index.xml","/CP070936_VMw.zip/metadata.zip","/CP070936_VMw.zip/vib20/CP070936/HPE_bootbank_CP070936_HPG2.4-8.0.0.20613240.vib","/CP070936_VMw.zip/metadata.zip/vendor-index.xml","/CP070936_VMw.zip/metadata.zip/vmware.xml","/CP070936_VMw.zip/metadata.zip/vibs/CP070936-5275262355044118200.xml","/CP070936_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070936_HPG2.4-8.0.0.20613240.xml"],"Name":"CP070936.zip","SHA1Sum":"aa7030601a5710b277fbf9811b367a67ff81757e","SHA256Sum":"4d5aaa63f1146ea8641b00586286ec99a42581ba09d23c2d6f875aacd6afd8c7","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2","VibList":[{"Name":"CP070936","Version":"HPG2.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_30274f09155b4fd190f10abc8a","SupportedDevices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070602.exe","SHA1Sum":"d3c7229bc8bf483e35aee681d82cb70348e557d3","SHA256Sum":"4cdf252226f0ee766177bc04a4b5afb0fe88f2db867c48fb8cb39dccec23d262","SHA512Sum":"e70128717ab54bf5cb1518d8277c25628add0991b60c249d770f95871cdd514f04188b45ef1df3d77cb4782e23aeb93fd5575c2fe70c188ed5c0989e17886044"}],"ComponentSizeInKB":1718,"CompsigList":["cp070602.compsig"],"FileList":["cp070602.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"Name":"cp070602.exe","SHA1Sum":"d3c7229bc8bf483e35aee681d82cb70348e557d3","SHA256Sum":"4cdf252226f0ee766177bc04a4b5afb0fe88f2db867c48fb8cb39dccec23d262","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3cb0e260312a4259a3a98374a1","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072685.zip","SHA1Sum":"8cc3c3b29c49dcb6d54be6a01e00e76d3eb170ef","SHA256Sum":"fcf04144e3dc8166dc6cd308a07e6e09770bc8bdbae4711746e85a0a8d1d9a90","SHA512Sum":"75451b99151f7f2ac248bd3f93a56b20c4e7bf4060250f93524b1f3a6aefe281bcda65c9687067f20cb3d562cb293713f534d349786a727f8a6286a481e96e6e"}],"ComponentSizeInKB":459,"CompsigList":["cp072685.compsig"],"FileList":["/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip","/cp072685.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/index.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_238.1.147.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_238.1.147.0-1OEM.800.1.0.20613240.vib","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/bnxtroce--6712727770626991197.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/bnxtnet-8704076471572814147.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.800.1.0.20613240.xml"],"Name":"cp072685.zip","SHA1Sum":"8cc3c3b29c49dcb6d54be6a01e00e76d3eb170ef","SHA256Sum":"fcf04144e3dc8166dc6cd308a07e6e09770bc8bdbae4711746e85a0a8d1d9a90","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"bnxtnet","Version":"238.1.147.0-1OEM.800.1.0.20613240"},{"Name":"bnxtroce","Version":"238.1.147.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:238.1.247.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtnet:238.1.147.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtroce:238.1.147.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b9ea6d3969da42ee828b008fba","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U46","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVLACBA0HPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-2c27a7a9a4_0HPD4-2.1_amd64.deb","SHA1Sum":"8de9679bfb647d19af3a3afe235ae756ec950747","SHA256Sum":"7fb65d1613df886d5d9fed0f09e312b701555546289a65eb93e985aed4648049","SHA512Sum":"8c31e0b80e4444ebcfc5ea4eab4ad116b697059e6375c560936820c814dbfeb5be71a025486676706c0e63faac859646824d11b99056e472fff93736cbf7a0f7"}],"ComponentSizeInKB":4660,"CompsigList":["firmware-hdd-2c27a7a9a4_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/CP073160.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/WVLACBA0HPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073160.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073160.scexe"],"Name":"firmware-hdd-2c27a7a9a4_0HPD4-2.1_amd64.deb","SHA1Sum":"8de9679bfb647d19af3a3afe235ae756ec950747","SHA256Sum":"7fb65d1613df886d5d9fed0f09e312b701555546289a65eb93e985aed4648049","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWKGU Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d95565374c8f43f3b4588b6fdd","SupportedDevices":["4d2340a5-3042-3430-3030-304a574b4755"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H10","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H10_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"H10_2.70_08_19_2026.fwpkg","SHA1Sum":"08e72697585e16c24779fa8988f45e58f796ae0e","SHA256Sum":"f6be016d92ff8e1a1fbbf0e62d0302248aa151ed99286303870e819cac6545c9","SHA512Sum":"2962ac1c64fad45a6173356a2dba948810bc6f4b4d7efd49eada043c87e25c8e7222b79d5d419f04a2606c809462ca6387bace5c25a03a00c06b34b34e4b04ae"}],"ComponentSizeInKB":32803,"CompsigList":[],"FileList":["H10_2.70_08_19_2026.signed.flash","H10_2.70_08_19_2026.xml","payload.json"],"Name":"H10_2.70_08_19_2026.fwpkg","SHA1Sum":"08e72697585e16c24779fa8988f45e58f796ae0e","SHA256Sum":"f6be016d92ff8e1a1fbbf0e62d0302248aa151ed99286303870e819cac6545c9","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023a"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H10","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6b0188a0ae5e499281816626e4","SupportedDevices":[],"SupportedOperatingSystems":[],"SupportedPlatforms":false,"SupportedProducts":["H10","H10","H10","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","FTP"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52004TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"CP072403.zip","SHA1Sum":"48aa1e244acc75d02a593e6c53fb0c9d801e2268","SHA256Sum":"34b2e3b4a7d38049a68f0bc0ab72a6b4d6cf26984387adc71c9af5861c26e3b5","SHA512Sum":"c140140917510d1859f3aa56689c81c8d9dc7a0794ba879e32f4eeae9397b1ee8507f54b4bf7377af895a40e0f104a5720f838673fc961e58aa614e4214cb268"}],"ComponentSizeInKB":17947,"CompsigList":["CP072403.compsig"],"FileList":["/CP072403_BUILD_1.data","/CP072403.vmexe64","/CP072403.vmfile","/CP072403_VMw.zip","/CP072403.xml","/payload.json","/CP072403_VMw.zip/index.xml","/CP072403_VMw.zip/vendor-index.xml","/CP072403_VMw.zip/metadata.zip","/CP072403_VMw.zip/vib20/CP072403/HPE_bootbank_CP072403_HPG4.1-8.0.0.20613240.vib","/CP072403_VMw.zip/metadata.zip/vendor-index.xml","/CP072403_VMw.zip/metadata.zip/vmware.xml","/CP072403_VMw.zip/metadata.zip/vibs/CP072403-7040956352853403868.xml","/CP072403_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072403_HPG4.1-8.0.0.20613240.xml"],"Name":"CP072403.zip","SHA1Sum":"48aa1e244acc75d02a593e6c53fb0c9d801e2268","SHA256Sum":"34b2e3b4a7d38049a68f0bc0ab72a6b4d6cf26984387adc71c9af5861c26e3b5","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3330-3834-30475753584c"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP072403","Version":"HPG4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK003840GWSXL Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK003840GWSXL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a87a7480a0714dadb390b9ddab","SupportedDevices":["562340a5-304b-3330-3834-30475753584c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//P14473110.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.10"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//P14473110.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.10"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//P14473110.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.10"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.10-1//firmware//P14473110.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.10"}]},"Files":[{"Checksum":[{"Filename":"cp070314.exe","SHA1Sum":"fe1e4fc07ddf1a2d699bc804d447496cc2d8c9d9","SHA256Sum":"fd049eb53434c87eadbc58bcdbb233123a5ec058e9081d0547e6c4778e09aa10","SHA512Sum":"f120d13953e368bcfb82e6352ce2f64beaae79d820d605a397e2f85938b07d2021f782acd19f6658dd7dae6e2ad52b47eaa5cf1a8670b56ae2531b472eba4dfa"}],"ComponentSizeInKB":4495,"CompsigList":["cp070314.compsig"],"FileList":["cp070314.xml","cpqsetup.exe","elxflashStandalone-windows-14.4.731.10-1/firmware/","elxflashStandalone-windows-14.4.731.10-1/firmware/B1447315.grp","elxflashStandalone-windows-14.4.731.10-1/firmware/P14473110.grp","elxflashStandalone-windows-14.4.731.10-1/win/","elxflashStandalone-windows-14.4.731.10-1/win/elxflash.bat","elxflashStandalone-windows-14.4.731.10-1/win/winlpcfg.bat","elxflashStandalone-windows-14.4.731.10-1/win/x64/","elxflashStandalone-windows-14.4.731.10-1/win/x64/elxflash.exe","elxflashStandalone-windows-14.4.731.10-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-14.4.731.10-1/win/x64/libdfc.dll","elxflashStandalone-windows-14.4.731.10-1/win/x64/readme.txt","elxflashStandalone-windows-14.4.731.10-1/win/x64/RM.INI","elxflashStandalone-windows-14.4.731.10-1/win/x64/WinLpCfg.exe","fwmatrix.txt","elxflashStandalone-windows-14.4.731.10-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","reference.xml"],"Name":"cp070314.exe","SHA1Sum":"fe1e4fc07ddf1a2d699bc804d447496cc2d8c9d9","SHA256Sum":"fd049eb53434c87eadbc58bcdbb233123a5ec058e9081d0547e6c4778e09aa10","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.04.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2025 x64","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_972da401be134113a5b3e69266","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Files":[{"Checksum":[{"Filename":"firmware-disk-enclosure_5.04-3.1_amd64.deb","SHA1Sum":"c2ac01024606e093198a2106410af9f8d856bfa2","SHA256Sum":"85f168b1f0223157765c8fb61a7e6999a580f7016bc32d71ac90c273d74324cf","SHA512Sum":"1cb794ca736e56381592cc70063c524d1189cab5252fefc4585a2ffcf89e9eabd9516fccc19a981cd067a7fb2b10dcad362f61e1503d20af84f88b1eb6b0a6ac"}],"ComponentSizeInKB":2316,"CompsigList":["firmware-disk-enclosure_5.04-3.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/CP072184.xml","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072184.scexe","./usr/lib/x86_64-linux-gnu/firmware-disk-enclosure-5.04-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072184.scexe"],"Name":"firmware-disk-enclosure_5.04-3.1_amd64.deb","SHA1Sum":"c2ac01024606e093198a2106410af9f8d856bfa2","SHA256Sum":"85f168b1f0223157765c8fb61a7e6999a580f7016bc32d71ac90c273d74324cf","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c46a5509aa964cf08d9a9fe3e3","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072297.exe","SHA1Sum":"1aaf4257241cb74822dc73e76d07dc621ae44b29","SHA256Sum":"21680bd622eccbb1c56ec2cdaa5570096f58435e7a1c01c8818a74756ff23da8","SHA512Sum":"a7cb231dbd131c1c63fe0ff426623cf814bb6829e1d2be880f27e69aee3d308fd2a5ecd15667ba5ec9c62b8447ec3e7363031c1abdbff42509d362861e088ed3"}],"ComponentSizeInKB":604,"CompsigList":["cp072297.compsig"],"FileList":["cp072297.xml","cpqsetup.exe","installer.dll","pnp/","pnp/cannonlake-h.cat","pnp/CannonLake-HSystem.inf","pnp/CannonLake-HSystemThermal.inf","pnp/coffeelake.cat","pnp/CoffeelakeSystem.inf","pnp/null_heci.cat","pnp/NULL_HECISystem.inf"],"Name":"cp072297.exe","SHA1Sum":"1aaf4257241cb74822dc73e76d07dc621ae44b29","SHA256Sum":"21680bd622eccbb1c56ec2cdaa5570096f58435e7a1c01c8818a74756ff23da8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19928.8615"}],"InstallationDependency":{},"Name":"Identifiers for Intel Xeon E-22xx Processor for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_43d9225372234f6dad6a049c03","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":true,"SupportedProducts":["U43","U44","U48","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U40_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u40-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"82a9f2adc62f36f8b1ae0be04afb25ced4fc3245","SHA256Sum":"a053775dada57edbd49801360963eb804d8bf64b5c88e161bc9950cb7c300ee3","SHA512Sum":"87f90aed1b1fc166027d6403e1b6ad7f351fa4484da76a1978fd421359359864d8486ce62d930bce8f09939e7240565ba8d316a6410a6eb9f7e71d7a40ac71e1"}],"ComponentSizeInKB":11491,"CompsigList":["firmware-system-u40-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.70_2026_08_19-1.1/CP073177.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.70_2026_08_19-1.1/U40_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u40-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073177.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073177.scexe"],"Name":"firmware-system-u40-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"82a9f2adc62f36f8b1ae0be04afb25ced4fc3245","SHA256Sum":"a053775dada57edbd49801360963eb804d8bf64b5c88e161bc9950cb7c300ee3","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8822fe2bbf0b4302989a48acfe","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","6.0","11.0","15.0","9.0","8.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U40","U40"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel9u7.x86_64.rpm","SHA1Sum":"82923536eeae167fff31cd772f84f315d3d26205","SHA256Sum":"5468cacd3c067de390ad2cc20c1ed37cbcd4e8298e793a8159a56a6fed573523","SHA512Sum":"daa74f9124ffffed42457bb10fc325e5d7fd66e852b039f668ca20e694bd76c9177ec1aac95ffe3dcf383a44a391be50279ca3af76522dec59f45e4b9b382484"}],"ComponentSizeInKB":78,"CompsigList":["kmod-kernel-mft-mlnx-4.36.0-147.1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/kernel-mft-mlnx","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/lib/.build-id","./usr/lib/.build-id/72","./usr/lib/.build-id/72/a03a9ff597f1dea9a25195d6f5b808cbc1abc4","./usr/lib/.build-id/e0","./usr/lib/.build-id/e0/5557941ae1690cf046829593e05361a19f3ab5","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"Name":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel9u7.x86_64.rpm","SHA1Sum":"82923536eeae167fff31cd772f84f315d3d26205","SHA256Sum":"5468cacd3c067de390ad2cc20c1ed37cbcd4e8298e793a8159a56a6fed573523","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"mft-4.36.0-147.rhel9u7.x86_64.rpm","SHA1Sum":"0b1881d829bd19d0ed9505644be7ebda8de7045d","SHA256Sum":"1589a5097173b4a7351377ffcf24a43a666dc54d4fc05485081ef89d31f78009","SHA512Sum":"566163602e6dd40b709ef0ec2cbd44fb2fb91d6244d508d8db3f38427fbd53ec782e4945863f42537a67f4a10bba7d246311b5d1245610d9066f5b450993570c"}],"ComponentSizeInKB":29832,"CompsigList":["mft-4.36.0-147.rhel9u7.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.rhel9u7.x86_64.rpm","SHA1Sum":"0b1881d829bd19d0ed9505644be7ebda8de7045d","SHA256Sum":"1589a5097173b4a7351377ffcf24a43a666dc54d4fc05485081ef89d31f78009","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 9 Update 7 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8c67bdbe86684bc18826a10734","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-102115b30237"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","02020001","03020101","03030201"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150700.51-150.1.sles15sp7.x86_64.rpm","SHA1Sum":"f2216e80c587a72d626faca9b632c02c235ba1ee","SHA256Sum":"05fa5081d735141345f7766c3db85e35be9bad5a7885113dc7fef414a8fd6c23","SHA512Sum":"8b6e48a69ba3b68313dfe7d196664b71e6f8c6c5bf9aba666fd1f19c308a9b53652122afab30bc1d3a4066888032e19b150ebc3c43f9f1b04c68f90842874be5"}],"ComponentSizeInKB":78,"CompsigList":["kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150700.51-150.1.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/mst_pci.ko","./lib/modules/6.4.0-150700.51-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"Name":"kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150700.51-150.1.sles15sp7.x86_64.rpm","SHA1Sum":"f2216e80c587a72d626faca9b632c02c235ba1ee","SHA256Sum":"05fa5081d735141345f7766c3db85e35be9bad5a7885113dc7fef414a8fd6c23","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"mft-4.36.0-147.sles15sp7.x86_64.rpm","SHA1Sum":"d8850582725d58314b8ab0cf9a1f79ca0a54282e","SHA256Sum":"03643b11dfd739c816e75c3c10ea58bb00eced814ba190c1cab04f333efb4314","SHA512Sum":"40be9ad533e809323e0f8e8dd95b8bd1dcd9ac8dc296d05e3f048ae285780b454a93de0539a015ec7f52b1bfb1b649f3b320fae915327386e512bb0336176cf2"}],"ComponentSizeInKB":29836,"CompsigList":["mft-4.36.0-147.sles15sp7.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.sles15sp7.x86_64.rpm","SHA1Sum":"d8850582725d58314b8ab0cf9a1f79ca0a54282e","SHA256Sum":"03643b11dfd739c816e75c3c10ea58bb00eced814ba190c1cab04f333efb4314","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP7 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_53f9c4daa268415e9a62a28018","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","03030201","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Files":[{"Checksum":[{"Filename":"firmware-d8000-0130-13.1.x86_64.rpm","SHA1Sum":"2e118faea754f64e67554dd630c3a437c6ed18e1","SHA256Sum":"afad8cfa3098956f6a185277acb959b3231aaa3470db595329ed760f5c87c5fc","SHA512Sum":"8524d92f21b2e3d80948b660dcfc1656ff957bbd4215e15e13b24ee41d7bd174259e3489a2854e06f524fbfd080a1848346051db42ff8828b52e0ec1d13cb0ec"}],"ComponentSizeInKB":13454,"CompsigList":["firmware-d8000-0130-13.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/CP072204.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072204.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072204.scexe"],"Name":"firmware-d8000-0130-13.1.x86_64.rpm","SHA1Sum":"2e118faea754f64e67554dd630c3a437c6ed18e1","SHA256Sum":"afad8cfa3098956f6a185277acb959b3231aaa3470db595329ed760f5c87c5fc","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2e7e8bfdf3b645e485e502281d","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","9.0","15.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"sut-6.9.0-17_amd64.deb","SHA1Sum":"48c0b335860d91fa57c6a370a97f108bb30b188e","SHA256Sum":"a1c117bc23345ac68004f637b9a631acbc1adb5e79ebc88514dfa57226cababf","SHA512Sum":"3ad4ce0dd94522d856637fe62d4367261841de72cc5ffd680fa92edd993eae47f503034560db8d90350325a76cd2e86ba8849163e100fe6e3a86520b58f326bc"}],"ComponentSizeInKB":19165,"CompsigList":["sut-6.9.0-17_amd64.compsig"],"FileList":["./README.txt","./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/lib/x86_64-linux-gnu/libQt5Core.so.5","./opt/sut/lib/x86_64-linux-gnu/libdouble-conversion.so.3","./opt/sut/lib/x86_64-linux-gnu/libicudata.so.70.1","./opt/sut/lib/x86_64-linux-gnu/libicui18n.so.70.1","./opt/sut/lib/x86_64-linux-gnu/libicuuc.so.70.1","./opt/sut/lib/x86_64-linux-gnu/libpcre2-16.so.0","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/share/doc/sut/changelog.gz","./usr/share/doc/sut/copyright","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml","./opt/sut/lib/x86_64-linux-gnu/libicudata.so.70","./opt/sut/lib/x86_64-linux-gnu/libicui18n.so.70","./opt/sut/lib/x86_64-linux-gnu/libicuuc.so.70"],"Name":"sut-6.9.0-17_amd64.deb","SHA1Sum":"48c0b335860d91fa57c6a370a97f108bb30b188e","SHA256Sum":"a1c117bc23345ac68004f637b9a631acbc1adb5e79ebc88514dfa57226cababf","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"6.9.0.0"}],"InstallationDependency":{},"Name":"Integrated Smart Update Tools for Ubuntu Linux x64","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c3c90f140546408cbaf7a30f31","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-102b-053a159004bd","a6b1a447-382a-5a4f-103c-3307159004bd","a6b1a447-382a-5a4f-103c-3306159004bd"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["HP Smart Update Tools (HP SUT)","A55","A55","A56","A56","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","U37","A46","U47","U38","U38","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","SPP","A42","U56","U61","U60","U64","U46","I43","I44","I42","I45","U65","U65","U58","U59","U63","U62","U63","U54","U58","U58","U72","I46","U71","R14","A66","A66","U68","HPE ProLiant DL380m Gen12","U72","U68","U69","U69","H10","U54","U54","U57","U65","H11","A58","A59","U66","U68","U74","U71","U77","A72","HPE ProLiant Compute DL384VR Gen13"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"238.1.169000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"238.1.169000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"238.1.169000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"238.1.169000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"238.1.169000"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-nxe-1.27.0-1.1.x86_64.rpm","SHA1Sum":"287b08bd4e6bc1a09f8bce9cc1354df30f53ea64","SHA256Sum":"f2638a410a628b4073b22e15392f28ac30089d2d78aafcfa4226918d13b20be1","SHA512Sum":"d142c2c8d664d54d65a484f7b4fcf096c98c835a64762ac6ed127c97db1f3a572004a2b323979846d985d3be508746b418b24488f6a864dcecbe9946201ed9a0"}],"ComponentSizeInKB":8019,"CompsigList":["firmware-nic-bcm-nxe-1.27.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/CP072710.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/CP072710.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072710.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072710.scexe"],"Name":"firmware-nic-bcm-nxe-1.27.0-1.1.x86_64.rpm","SHA1Sum":"287b08bd4e6bc1a09f8bce9cc1354df30f53ea64","SHA256Sum":"f2638a410a628b4073b22e15392f28ac30089d2d78aafcfa4226918d13b20be1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"1.27.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_54f78a9ffa874b079ea99d83d6","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03030201","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U50_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073121.exe","SHA1Sum":"4dd18369275ac8a7a00de3d2c532083650ac6e4b","SHA256Sum":"1103d8c7fafa6e503761a8008bffc19e8e62567adf1b5c060ab1857f3bf034d4","SHA512Sum":"74bf9f9648594d4e94a0111b7b05c3130e4952d2b658dd26b33d56cc3b25179f5cc9a43654e764aea0fa7b282811fff8a5c8c3a49c826ff921c8f70a16274316"}],"ComponentSizeInKB":33441,"CompsigList":["cp073121_part1.compsig","cp073121_part2.compsig"],"FileList":["cp073121.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U50_2.70_08_19_2026.signed.flash"],"Name":"cp073121.exe","SHA1Sum":"4dd18369275ac8a7a00de3d2c532083650ac6e4b","SHA256Sum":"1103d8c7fafa6e503761a8008bffc19e8e62567adf1b5c060ab1857f3bf034d4","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d45f61955fc141829dc99fbcc2","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U50"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-iavf-4.13.35-1.rhel9u8.x86_64.rpm","SHA1Sum":"55537a4861f6a069c70b6f06024cef69b84d0219","SHA256Sum":"e36c470260f3bc50e69d24c8c49c795498c06b5678e8bcf78f78526125c84733","SHA512Sum":"6467e341ec222c0155e27b24832f48c949f5d3bdd4df3f1a1a7a19afdc3d6c1b4c5ffc59dbac4a2d6ab74baa9bc5f909d7de48d1b0702155e363f45001edfd1d"}],"ComponentSizeInKB":188,"CompsigList":["kmod-hp-iavf-4.13.35-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-iavf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/a6","./usr/lib/.build-id/a6/9cb870a4fb6f78a5630512073031def0edfa75","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"Name":"kmod-hp-iavf-4.13.35-1.rhel9u8.x86_64.rpm","SHA1Sum":"55537a4861f6a069c70b6f06024cef69b84d0219","SHA256Sum":"e36c470260f3bc50e69d24c8c49c795498c06b5678e8bcf78f78526125c84733","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"TypeOfChange":"1","Version":"4.13.35-1"},{"Checksum":[{"Filename":"kmod-hp-iavf-4.13.35-1.rhel9u7.x86_64.rpm","SHA1Sum":"72d4c17634fba3ac4e301193b91473787962c276","SHA256Sum":"a5ca9033a43242d9b7d94713d38148f8c15afe1df9fee953163ae2c4c7b1a5ec","SHA512Sum":"db0e9a7ce131699b9210f26830f4d1086d4ba53c1fcb510de3a6199ca78d3fece5cbf2d8fc4100348241fb02f489f1059c6a80d8ff74c1e303b2df5b5b049ae8"}],"ComponentSizeInKB":193,"CompsigList":["kmod-hp-iavf-4.13.35-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-iavf.conf","./etc/dracut.conf.d/hp-iavf-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-iavf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-iavf/iavf.ko","./usr/lib/.build-id","./usr/lib/.build-id/5f","./usr/lib/.build-id/5f/dfebbfb32336046931cf2b6064cfa6169c34d3","./usr/share/smartupdate/kmod-hp-iavf/component.xml"],"Name":"kmod-hp-iavf-4.13.35-1.rhel9u7.x86_64.rpm","SHA1Sum":"72d4c17634fba3ac4e301193b91473787962c276","SHA256Sum":"a5ca9033a43242d9b7d94713d38148f8c15afe1df9fee953163ae2c4c7b1a5ec","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0e19bfd1"],"TypeOfChange":"1","Version":"4.13.35-1"}],"InstallationDependency":{},"Name":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-iavf","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b9dc5b91f3f0481a86bbe38c11","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-15ff8086000c","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd_5.1.0-2197.8-ubuntu24_amd64.deb","SHA1Sum":"add3bdce3be02bc71262be7f2ad5668529637694","SHA256Sum":"c00f473b10d302faeb1eea8e8fa117d7b3a4d1c0dede606ab7f50902bc98ec00","SHA512Sum":"881c60450f2ee57d21e180b5ac1fbac668cdf025e5c82b1eaf2fa75914318303ef997d7398af4bf272694de56a588e2f3617224c0fe513204c389292f9d910c3"}],"ComponentSizeInKB":8882,"CompsigList":["amsd_5.1.0-2197.8-ubuntu24_amd64.compsig"],"FileList":["./etc/default/ahslog","./etc/default/amsd","./etc/default/amsd_rev","./etc/default/cpqIde","./etc/default/cpqScsi","./etc/default/cpqiScsi","./etc/default/mr_cpqScsi","./etc/default/smad","./etc/default/smad_rev","./lib/udev/rules.d/81-cpqFca.rules","./lib/udev/rules.d/81-cpqiScsi.rules","./sbin/ahslog","./sbin/amscli","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqIde","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./sbin/smad","./sbin/smad_rev","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/share/amsd/amsd.license","./usr/share/doc/amsd/README.Debian","./usr/share/doc/amsd/changelog.Debian.gz","./usr/share/doc/amsd/copyright","./usr/share/man/man1/ahslog.1m.gz","./usr/share/man/man1/smad.1m.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/smartupdate/amsd/component.xml"],"Name":"amsd_5.1.0-2197.8-ubuntu24_amd64.deb","SHA1Sum":"add3bdce3be02bc71262be7f2ad5668529637694","SHA256Sum":"c00f473b10d302faeb1eea8e8fa117d7b3a4d1c0dede606ab7f50902bc98ec00","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"5.1.0"}],"InstallationDependency":{},"Name":"Agentless Management Service for Ubuntu 24.04 LTS","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_47ba6f67f28344e6af845518e7","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","A40","U30","U32","I42","U38","U38","U34","I43","A42","A43","A41","A42","A43","A42","A43","U46","U46","A55","A56","A55","A56","U54","U54","U54","U63","U63","U59","U58","U58","I45","I44","U69","U69","U68","U68","U68","U77","U62","U71","U77","A72","U83"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070937.zip","SHA1Sum":"da303b2c21ace83675eb0befe674404003fd1d55","SHA256Sum":"7caa72d7012d22cc83a460754705ae9e1d62afafe6c7d2ff2cf6d4022745539b","SHA512Sum":"63361e2efcc6ccf4020d9f65a0ca3a79ec6c2ccf8c63f69409945bf7ac4a641b98b4b9440bc63f82eeb27f914e884b49bec3436b59f212a7184cbb5875fdd6a2"}],"ComponentSizeInKB":17658,"CompsigList":["CP070937.compsig"],"FileList":["/CP070937_BUILD_4.data","/CP070937.vmexe64","/CP070937.vmfile","/CP070937_VMw.zip","/CP070937.xml","/payload.json","/CP070937_VMw.zip/index.xml","/CP070937_VMw.zip/vendor-index.xml","/CP070937_VMw.zip/metadata.zip","/CP070937_VMw.zip/vib20/CP070937/HPE_bootbank_CP070937_HPD6.4-8.0.0.20613240.vib","/CP070937_VMw.zip/metadata.zip/vendor-index.xml","/CP070937_VMw.zip/metadata.zip/vmware.xml","/CP070937_VMw.zip/metadata.zip/vibs/CP070937--6928732070771402113.xml","/CP070937_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070937_HPD6.4-8.0.0.20613240.xml"],"Name":"CP070937.zip","SHA1Sum":"da303b2c21ace83675eb0befe674404003fd1d55","SHA256Sum":"7caa72d7012d22cc83a460754705ae9e1d62afafe6c7d2ff2cf6d4022745539b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070937","Version":"HPD6.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNL and EG002400JWJNN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_da389c98853b4e2ca18e5a964c","SupportedDevices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Files":[{"Checksum":[{"Filename":"cp068622.exe","SHA1Sum":"ad106791b45f10a79b7c526616713b7e295fab9a","SHA256Sum":"d4c113c5e17a27eaaca1febc2db02d7696c64c54b7717aa0b28e5a5786209e85","SHA512Sum":"07bd7aec8631d8dd711aac3926c7d500681b87b4593e94c2c6015186a79b2eb9c40d0c043f4458ee0c26b62e9b307bfb3194daeefa07a96089f32a2ba8f27435"}],"ComponentSizeInKB":3336,"CompsigList":["cp068622.compsig"],"FileList":["4IYRHPG7.bin","cp068622.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068622.exe","SHA1Sum":"ad106791b45f10a79b7c526616713b7e295fab9a","SHA256Sum":"d4c113c5e17a27eaaca1febc2db02d7696c64c54b7717aa0b28e5a5786209e85","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e4aa692ceed2495eac575e3869","SupportedDevices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072197.exe","SHA1Sum":"4f3c1706e671eca5447bc28dd60dbea806997b70","SHA256Sum":"45c26b2b5f7cacdd9e2498ed1fca668f1916ddf5b7967d0d3615cfda17a5e215","SHA512Sum":"5a23d0a9b7953708ebca71924a3f9f9c7af89dfb767e55444ae9425f93a9b9bc15d42dcdcbc08a768ca6d3cf6410ba096dc1f5496610babb48e4679d643c7c02"}],"ComponentSizeInKB":2432,"CompsigList":["cp072197.compsig"],"FileList":["cp072197.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072197.exe","SHA1Sum":"4f3c1706e671eca5447bc28dd60dbea806997b70","SHA256Sum":"45c26b2b5f7cacdd9e2498ed1fca668f1916ddf5b7967d0d3615cfda17a5e215","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d18aeb44d58a4095b4b031fc00","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159000d3","a6b1a447-382a-5a4f-15b3-1016159000d4","a6b1a447-382a-5a4f-15b3-101815900246"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","U34","U34","A40","U30","P89","U32","P89","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-bdfb8e99d9_0HPD9-2.1_amd64.deb","SHA1Sum":"21e186b3739b9a52bae75ce89a241019ce0fe798","SHA256Sum":"edcc04832df7c0be99a8d63cfba58f514134f1ccf9e09db0d27d6772831dd634","SHA512Sum":"e14f605728557415e39de643e982c64e4a92f3989ea26da8ee79b39b4706446e06e217d501270683ceef202a4126e6b998e28c010edc6a8764c2d737200658f5"}],"ComponentSizeInKB":4506,"CompsigList":["firmware-hdd-bdfb8e99d9_0HPD9-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/CP071767.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/SSKYBT512ND9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071767.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071767.scexe"],"Name":"firmware-hdd-bdfb8e99d9_0HPD9-2.1_amd64.deb","SHA1Sum":"21e186b3739b9a52bae75ce89a241019ce0fe798","SHA256Sum":"edcc04832df7c0be99a8d63cfba58f514134f1ccf9e09db0d27d6772831dd634","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1f243a97265142368b07595bdd","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070317.exe","SHA1Sum":"745c11fd0a5ad847bb9828118c5dd2b5a3e7e430","SHA256Sum":"356b6eaf5017f0da75d2df098f746e5e5f778e4065ac34e72f62c85b50201019","SHA512Sum":"54ee43de41de6dd0423e8c5a04a7eeda209a09b93f07e7146af70feba2cb91ecbf852f158f7d70efbbcdd1df9926dfbce501d8e87f280846d43ea223eb3a7684"}],"ComponentSizeInKB":4202,"CompsigList":["cp070317.compsig"],"FileList":["cp070317.xml","cpqsetup.exe","elxdrvr-fc-14.4.624.1-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"Name":"cp070317.exe","SHA1Sum":"745c11fd0a5ad847bb9828118c5dd2b5a3e7e430","SHA256Sum":"356b6eaf5017f0da75d2df098f746e5e5f778e4065ac34e72f62c85b50201019","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.624.1"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_42c244c364564278b0d9a491f3","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Files":[{"Checksum":[{"Filename":"cp068758.exe","SHA1Sum":"07290ec52eb31aad45ff534799d97d338017761d","SHA256Sum":"51db9e68ced18af9c6daf2b521a63ec310c8034043ba14a94e7173b85207fb58","SHA512Sum":"a6c960a1bdae82255072b8d3d0a9746c0a27cbb400a6ebdf2aa41c3caa2e0fb515c25afc644705e47837dbbb20cab55e4a210c497afe63bd19ed919714477377"}],"ComponentSizeInKB":3919,"CompsigList":["cp068758.compsig"],"FileList":["cp068758.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG08scHPDC.rel"],"Name":"cp068758.exe","SHA1Sum":"07290ec52eb31aad45ff534799d97d338017761d","SHA256Sum":"51db9e68ced18af9c6daf2b521a63ec310c8034043ba14a94e7173b85207fb58","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JWXKH Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_82fb0e5310174d9195ce89abea","SupportedDevices":["4d2340a5-3042-3631-3030-304a57584b48"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"CP070945.zip","SHA1Sum":"f3e3b0b1dc3aad00dcadb3c351f6fae01788b39a","SHA256Sum":"ee0a148f7082560093a469ab38b7a095b60f43b2e7f3498fc33635415add06f9","SHA512Sum":"55a6c5bf74474587712bd2011433fb45a97bb804142a1af1ea8f3269309887793ec14a21d6b99e83a596b74b6bbb8321e345887dc004aad4f2f1759aaf883aa5"}],"ComponentSizeInKB":19743,"CompsigList":["CP070945.compsig"],"FileList":["/CP070945_BUILD_5.data","/CP070945.vmexe64","/CP070945.vmfile","/CP070945_VMw.zip","/CP070945.xml","/payload.json","/CP070945_VMw.zip/index.xml","/CP070945_VMw.zip/vendor-index.xml","/CP070945_VMw.zip/metadata.zip","/CP070945_VMw.zip/vib20/CP070945/HPE_bootbank_CP070945_HPD8.5-8.0.0.20613240.vib","/CP070945_VMw.zip/metadata.zip/vendor-index.xml","/CP070945_VMw.zip/metadata.zip/vmware.xml","/CP070945_VMw.zip/metadata.zip/vibs/CP070945-3651765990428512566.xml","/CP070945_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070945_HPD8.5-8.0.0.20613240.xml"],"Name":"CP070945.zip","SHA1Sum":"f3e3b0b1dc3aad00dcadb3c351f6fae01788b39a","SHA256Sum":"ee0a148f7082560093a469ab38b7a095b60f43b2e7f3498fc33635415add06f9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8","VibList":[{"Name":"CP070945","Version":"HPD8.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWWQP and MB006000JWWQN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bce0494fcaa04ee8b04c057948","SupportedDevices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp073082.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000101","Version":"04.04.04.926"}]},"Files":[{"Checksum":[{"Filename":"firmware-spsgen10plus-04.04.04.926-1.1.x86_64.rpm","SHA1Sum":"cc13f8542a67a1c44fdc6fc6945a8f491ec2874b","SHA256Sum":"14de04a4ad6072f524dcfb133bf552c8093efb064cae644f60c7ff76d0405b09","SHA512Sum":"4a824eed22b55237554964ca87da053678e356c59ac94d989b1e5e0b4bdea3898e70ec5045eac6743ee42237dccf1b613d926dac0ac0175851fa3699302e2638"}],"ComponentSizeInKB":8385,"CompsigList":["firmware-spsgen10plus-04.04.04.926-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1/CP073087.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1/cp073082.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1/cp073082.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10plus-04.04.04.926-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073087.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073087.scexe"],"Name":"firmware-spsgen10plus-04.04.04.926-1.1.x86_64.rpm","SHA1Sum":"cc13f8542a67a1c44fdc6fc6945a8f491ec2874b","SHA256Sum":"14de04a4ad6072f524dcfb133bf552c8093efb064cae644f60c7ff76d0405b09","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000101"],"TypeOfChange":"1","Version":"04.04.04.926"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Plus Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f711bc667ceb4f52a4ea9bd621","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U56","H10","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021111.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.11"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021111.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.11"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.01"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.01"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020501.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.01"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021111.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.11"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021111.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.11"}]},"Files":[{"Checksum":[{"Filename":"cp070515.exe","SHA1Sum":"86cd04f673d59d615da234abdf2eea85d5411341","SHA256Sum":"02144797e69877c3441e4394adadc35083b947cc9fb1eb8eba7a49e2d8f59684","SHA512Sum":"aa6e40ea29d1d34f3a7061184b8910fe8622e5d3e9aa8c11447209bf0c0b7e2b726d95a3e919bc6260a6becf59c0bd88740d25bd2390c6fceb2abaec9e8480ef"}],"ComponentSizeInKB":3758,"CompsigList":["cp070515.compsig"],"FileList":["QLAFWUpdate.exe","adapters.properties","bk020501.bin","cp070515.xml","cpqsetup.exe","hbaapi2_x64.dll","installer.dll","mh021111.bin","payload.json","ql2xhai2.dll","qlafwupdate.properties","qlafwupdate.txt","qlcoutil.dll","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"Name":"cp070515.exe","SHA1Sum":"86cd04f673d59d615da234abdf2eea85d5411341","SHA256Sum":"02144797e69877c3441e4394adadc35083b947cc9fb1eb8eba7a49e2d8f59684","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.04.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2025 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":250,"RebootRequired":"yes","SWKeys":[{"Name":"qlogic","SWKeyExpectedPath":"firmware:qlogic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_214e027232994194ae8fe7a78f","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"cp068621.exe","SHA1Sum":"38a1c5c19ec14ce1171cc081a078a9d7e37aa4eb","SHA256Sum":"fcfc2072131aeefdfd8b13eac286e360314b445aae1d40444952aa81428f0e0b","SHA512Sum":"2a39cfa67bdbdfab4aebe5383fc68ca32e68c4dc40d3f8decfa923833cf596c22673c18c02667468d8ce6b60c9ea04335774f17998d47a789b744ebf32ea6330"}],"ComponentSizeInKB":3003,"CompsigList":["cp068621.compsig"],"FileList":["4IYVHPG5.rel","cp068621.xml","cpqsetup.exe","payload.json","setup.dll"],"Name":"cp068621.exe","SHA1Sum":"38a1c5c19ec14ce1171cc081a078a9d7e37aa4eb","SHA256Sum":"fcfc2072131aeefdfd8b13eac286e360314b445aae1d40444952aa81428f0e0b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_97f9bd5cfe0948f8812fc1eb5a","SupportedDevices":["4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3130-3932-3047574a5048","4d2340a5-304b-3030-3234-3047574b564b","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3330-3834-3047574a504b","4d2340a5-304b-3030-3438-3047574a504e","562340a5-304b-3030-3438-3047574a5045","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3030-3936-3047574a5046"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U45_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U45_3.70_08_19_2026.fwpkg","SHA1Sum":"e352582a0bed0ce0b23be9de685971d8ca28003c","SHA256Sum":"b819f312e77e8d2ffe15853b1fe88d2571655f2f980af32caa1200422e14634d","SHA512Sum":"72d0c97d0d8773e788353af327f1c40e082f6b4d5140c0acdd966d50dab2236a4e15bf018b0abadae2211b494c6a8dfbacab0865f8c176e6253d70082a387541"}],"ComponentSizeInKB":32825,"CompsigList":[],"FileList":["payload.json","U45_3.70_08_19_2026.signed.flash","U45_3.70_08_19_2026.xml"],"Name":"U45_3.70_08_19_2026.fwpkg","SHA1Sum":"e352582a0bed0ce0b23be9de685971d8ca28003c","SHA256Sum":"b819f312e77e8d2ffe15853b1fe88d2571655f2f980af32caa1200422e14634d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_455e9c5122e64e609d73b2169c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U45","HPE Apollo 6500 Gen10 System"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-fastlinq-kmp-default-8.76.6.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"4c0dc09c554b0aff31fa6b3f18953f88c051de0f","SHA256Sum":"df0146c78d6f774634c79cbaeaddf54726d484744cf89fe5b3eb196f4d462ad2","SHA512Sum":"4b83fbe81fdda509ba2d744bbc769456b1c119e0a78e8615d6a1bebe3fd0467005ae3f08a7be12f0bca5a11b3b9ec67258b8111ce069de28aa5bea527598b116"}],"ComponentSizeInKB":17705,"CompsigList":["qlgc-fastlinq-kmp-default-8.76.6.0_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"Name":"qlgc-fastlinq-kmp-default-8.76.6.0_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"4c0dc09c554b0aff31fa6b3f18953f88c051de0f","SHA256Sum":"df0146c78d6f774634c79cbaeaddf54726d484744cf89fe5b3eb196f4d462ad2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.76.6.0-1"},{"Checksum":[{"Filename":"qlgc-fastlinq-kmp-default-8.76.6.0_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"0e07d6cb94b8fa3d10ffa29918b9d4276d005864","SHA256Sum":"7ce113ea1c1b5d80eb299b53873cad51269b5a21ebf252b75c502afaabd36d10","SHA512Sum":"f2ba98c251cb368a6fc82e53c9012e111854485f972e9f50270350fff2d7d6a8eaa5d85b51363f030db522c5c09b8c5bca8b53840ad8970d87872ca7ce6d92f2"}],"ComponentSizeInKB":17790,"CompsigList":["qlgc-fastlinq-kmp-default-8.76.6.0_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qed.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qede.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qedf.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qedi.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/qlgc-fastlinq-kmp-default/component.xml"],"Name":"qlgc-fastlinq-kmp-default-8.76.6.0_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"0e07d6cb94b8fa3d10ffa29918b9d4276d005864","SHA256Sum":"7ce113ea1c1b5d80eb299b53873cad51269b5a21ebf252b75c502afaabd36d10","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64"],"TypeOfChange":"1","Version":"8.76.6.0-1"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"qlgc-fastlinq-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b64d2e8229ab43b281ba7e5f79","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-befd42bd64-HPG3-6.1.x86_64.rpm","SHA1Sum":"521f5904c2488eb59cec95a9aa2372c677529fef","SHA256Sum":"ab5e8ea1f81b747ff4eefd86994abfdd876e1bda563a71bb3d99ecc04271f5fc","SHA512Sum":"ab02d260494eac641964648bf1d2bea2f55f8636f032d7a2ca6ec515f547b33d04f34de2c7bae7e4b845c5dc5d20119655e54204a23f5a6674099e072eef4f67"}],"ComponentSizeInKB":9810,"CompsigList":["firmware-hdd-befd42bd64-HPG3-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/CP068911.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/K511HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068911.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068911.scexe"],"Name":"firmware-hdd-befd42bd64-HPG3-6.1.x86_64.rpm","SHA1Sum":"521f5904c2488eb59cec95a9aa2372c677529fef","SHA256Sum":"ab5e8ea1f81b747ff4eefd86994abfdd876e1bda563a71bb3d99ecc04271f5fc","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2a06adfbec30486d8f4a28dfef","SupportedDevices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U39","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U39_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021b","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u39-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"787e509726945dc7817c2a982f420135c7a6493e","SHA256Sum":"d92a116cd8ec3204e97828322deb2ba27d8354c7bfe31503dc7e0503afdd9abe","SHA512Sum":"4fbee7b5480191c65750dd9455502a08752391973be5f8a564d6f009c431a56a5b9a39c992d323bbd967617590a90eb0f7b78d78b82395f0d9bbed038b658e0f"}],"ComponentSizeInKB":11387,"CompsigList":["firmware-system-u39-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.70_2026_08_19-1.1/CP073174.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.70_2026_08_19-1.1/U39_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u39-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073174.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073174.scexe"],"Name":"firmware-system-u39-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"787e509726945dc7817c2a982f420135c7a6493e","SHA256Sum":"d92a116cd8ec3204e97828322deb2ba27d8354c7bfe31503dc7e0503afdd9abe","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021b"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10/HPE ProLiant XL420 Gen10 (U39) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U39","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e66ac0d8fb1541339f39ab7e9c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U39","U39"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for ML30 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SC_ML30GEN10Plus_ME_06.00.03.708.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"SC_ML30GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"cc2ec86a530e0e3fe98669be75ebdfe5f6f58eae","SHA256Sum":"57c41dc5b94a0fae02f5b12ab83006f169e4b73e92421dd4030fe970bf020fb9","SHA512Sum":"79d346e6edbca6b7ebd24a03601621819af662f6aba5cab89f84c72c98c057382977da16eebf0d090334a51c4dacb99f8a16e22537ae59fe86bbc87eeb67003b"}],"ComponentSizeInKB":2234,"CompsigList":[],"FileList":["payload.json","SC_ML30GEN10Plus_ME_06.00.03.708.signed.bin","SC_ML30GEN10Plus_ME_06.00.03.708.xml"],"Name":"SC_ML30GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"cc2ec86a530e0e3fe98669be75ebdfe5f6f58eae","SHA256Sum":"57c41dc5b94a0fae02f5b12ab83006f169e4b73e92421dd4030fe970bf020fb9","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus Servers","PackageFormat":"FWPKG","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2d819f0ca7314dc0937fdef529","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1.x86_64.rpm","SHA1Sum":"a6567e9778b860870dd16e299701db2f5afb3416","SHA256Sum":"46547ef3a5dc6e32c3419e9633bb5a1c9334564ac3886090e7953ff605006efa","SHA512Sum":"b654a405e0fcd995f190a36bfc4cdec4317de657cb36a460d90ba63e5b8d47aad010ff750c98b61d11a4b2b3a889146f8e0c4c2cd77122262a2a4169bbf5fdaf"}],"ComponentSizeInKB":8876,"CompsigList":["firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/CP071674.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071674.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071674.scexe"],"Name":"firmware-hca-mellanox-vpi-connectx6-mft-1.0.20-1.1.x86_64.rpm","SHA1Sum":"a6567e9778b860870dd16e299701db2f5afb3416","SHA256Sum":"46547ef3a5dc6e32c3419e9633bb5a1c9334564ac3886090e7953ff605006efa","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.20"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Linux x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ecef034b6c30441abc03e163d0","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 2p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900348","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"0fd38697b7f1220d20699dbed14b0280bfc796e2","SHA256Sum":"79988e3fd27742f8440169090c366e535b20f675e73113180dce908cd92ee3a2","SHA512Sum":"3b37c5f7380203820d1f167afc7422c59c814adca8062b67cc619c7654d1c65a8a36e0899a20bb2a227c16824811f291291e9b5b88be5856c6c061afd078525f"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.signed","20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653436A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"0fd38697b7f1220d20699dbed14b0280bfc796e2","SHA256Sum":"79988e3fd27742f8440169090c366e535b20f675e73113180dce908cd92ee3a2","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900348"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 2-port QSFP56 PCIe4 x16 OCP3 MCX653436A-HDAI Adapter : HPE part numbers  P31348-B21 and P31348-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653436A-HDAI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_105eae77db3d48ce97184e7c75","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15900348"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57416 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957416A4162HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41593","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957416A4162HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41593","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957416A4162HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41593","Version":"238.1.169.0"}]},"Files":[{"Checksum":[{"Filename":"BCM238.1.169.0_BCM957416A4162HC.fwpkg","SHA1Sum":"3659913234ddf8eb130e1e688ab4c0b91034401c","SHA256Sum":"ff8d1ddaa39f6d5df18e698d1be55b30bc2be927e02fbe57d73671386cd55f45","SHA512Sum":"5b56d27becfd1e6ee86ce38484a469023e64a95c8794d59d0647b117139e93b9a3d6719feea9df756b6de793f158ebcaefbb37eb14a7cd91debc6afbfbff7564"}],"ComponentSizeInKB":1607,"CompsigList":[],"FileList":["BCM238.1.169.0_BCM957416A4162HC.HPb","BCM238.1.169.0_BCM957416A4162HC.xml","payload.json"],"Name":"BCM238.1.169.0_BCM957416A4162HC.fwpkg","SHA1Sum":"3659913234ddf8eb130e1e688ab4c0b91034401c","SHA256Sum":"ff8d1ddaa39f6d5df18e698d1be55b30bc2be927e02fbe57d73671386cd55f45","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593"],"TypeOfChange":"1","Version":"238.1.169.0"}],"InstallationDependency":{},"Name":"Broadcom Firmware Package for BCM57416 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE_57416_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1d9c02a53cca48e78de42c3b2c","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41593"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U32_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u32-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"161c67102eebe352c103e7f040f06c249ccfd102","SHA256Sum":"86472462910a909d91bc97f9f1cae0212e8dbc2160a5b93071c744ec23bf3151","SHA512Sum":"011e0f71a96592800473ef87e151a6310c40f3987359514921456ebade265f709a01776a63253a17feef65edb7881702ee405574f74dd4c274e323bcef7ca6f1"}],"ComponentSizeInKB":11575,"CompsigList":["firmware-system-u32-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.70_2026_08_19-1.1/CP073150.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.70_2026_08_19-1.1/U32_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u32-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073150.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073150.scexe"],"Name":"firmware-system-u32-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"161c67102eebe352c103e7f040f06c249ccfd102","SHA256Sum":"86472462910a909d91bc97f9f1cae0212e8dbc2160a5b93071c744ec23bf3151","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL360 Gen10 (U32) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c00e095c62f64179a92ddb8a26","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","11.0","7.0","6.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U32"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp068764.exe","SHA1Sum":"661882dd7108534a10e81a247ba00c5e8d66a0c3","SHA256Sum":"4f9f1ebbe58cc133ca56a62c3e5cbd2d0269b17d1d27c0610496d27d70d41885","SHA512Sum":"29ea68c01f52de911adc127491fea5885f95d597a211cb90221d98646fb4f0a17215b282d3c184eff754dfea7c12edddb9278fa3a70dfe7dfaa626b27c6a00fd"}],"ComponentSizeInKB":3179,"CompsigList":["cp068764.compsig"],"FileList":["cp068764.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA15SEE0HPD6.rel"],"Name":"cp068764.exe","SHA1Sum":"661882dd7108534a10e81a247ba00c5e8d66a0c3","SHA256Sum":"4f9f1ebbe58cc133ca56a62c3e5cbd2d0269b17d1d27c0610496d27d70d41885","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EG001800JWJNL and EG002400JWJNN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5388d296fb844a3388089e9558","SupportedDevices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U32_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U32_3.70_08_19_2026.fwpkg","SHA1Sum":"bef936df519d0d5a7f839b77f7bc4d66a4e2571f","SHA256Sum":"20fb253782f72e2e4b2744688b80d3e65a6c75f969c81db91bf902ac8e31da60","SHA512Sum":"aeee582a5040aba9e7b1d9e34845b9dcfed573074cd269b142d94d3c4bb94a2717b54e4c7c8808a34e4505d265ab35a3b84d2c92893dd3fa41b1adf90f38e353"}],"ComponentSizeInKB":32828,"CompsigList":[],"FileList":["payload.json","U32_3.70_08_19_2026.signed.flash","U32_3.70_08_19_2026.xml"],"Name":"U32_3.70_08_19_2026.fwpkg","SHA1Sum":"bef936df519d0d5a7f839b77f7bc4d66a4e2571f","SHA256Sum":"20fb253782f72e2e4b2744688b80d3e65a6c75f969c81db91bf902ac8e31da60","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL360 Gen10 (U32) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_485633879a6d4d05ab24001e8a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U32"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssacli-6.65-9.0.x86_64.rpm","SHA1Sum":"a2db3332734d81af7eb6f7c1bd41822b69d34570","SHA256Sum":"a3b9f01aea3532da9e9539d15d888814e006faf1086b7022c10d7c788657b26d","SHA512Sum":"5ae1bd8a3c509a2b6ccc59023ea598923f77f71233e5961d54acca2c89d7dee9dee2c8cf3dee0f34fa2e667b1421bf3cb080cbc1f0c1a4a332e8c473bd7dcb53"}],"ComponentSizeInKB":12953,"CompsigList":["ssacli-6.65-9.0.x86_64.compsig"],"FileList":["./opt/smartstorageadmin/ssacli","./opt/smartstorageadmin/ssacli/bin","./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-6.65-9.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/man/man8/ssacli.8.gz","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/smartupdate/ssacli/component.xml"],"Name":"ssacli-6.65-9.0.x86_64.rpm","SHA1Sum":"a2db3332734d81af7eb6f7c1bd41822b69d34570","SHA256Sum":"a3b9f01aea3532da9e9539d15d888814e006faf1086b7022c10d7c788657b26d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssacli","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f20df565e4f4f60a5b5d0887b","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","I45","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U63","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U57","U65","U62","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071620.exe","SHA1Sum":"27672e2ac1a1818c56aa91fcd6e41bd208c4a76f","SHA256Sum":"419c59aa2f4c96cfa2220aea9b7978de2ceb316bc3e49cd6ce31b7b7ff14053d","SHA512Sum":"5a47f658e2269e3709d9b2c42b1f89a7e8be5f6a5224f31160a4f373b78211d2915046617650f485654dc57cbd376be4712a12a36022d86e4cf8a09ca1f77e68"}],"ComponentSizeInKB":922,"CompsigList":["cp071620.compsig"],"FileList":["cp071620.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","megasas35.inf","megasas35.pdb","megasas35.RttMeta","megasas35.sys","nodev.inf"],"Name":"cp071620.exe","SHA1Sum":"27672e2ac1a1818c56aa91fcd6e41bd208c4a76f","SHA256Sum":"419c59aa2f4c96cfa2220aea9b7978de2ceb316bc3e49cd6ce31b7b7ff14053d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.738.8.0"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2025 edition","PackageFormat":"","PerDeviceInstallTimeSeconds":400,"RebootRequired":"yes","SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5be1cfb2626b4cceb0bd3f33eb","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.31"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.31"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.31"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.31"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.31"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.31"}]},"Files":[{"Checksum":[{"Filename":"cp072524.exe","SHA1Sum":"6b2d3f2bdebe0276978dd99d6cd9802bb1afb890","SHA256Sum":"a860d1d4c3cd1bea8984a834e443cb353987debbdb51b2f61d26b2540716628d","SHA512Sum":"c079833f6254d3bd619a5f33e053084db970db432bec124f34e535dc15a100a4c6c76dac5441361cc602ed72886300f2a89a6498734fdab46d34fa2793163661"}],"ComponentSizeInKB":4014,"CompsigList":["cp072524.compsig"],"FileList":["cp072524.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/hp_mbi_7.19.31.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLMAPIa.dll","QLNICFWUpg.exe","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp072524.exe","SHA1Sum":"6b2d3f2bdebe0276978dd99d6cd9802bb1afb890","SHA256Sum":"a860d1d4c3cd1bea8984a834e443cb353987debbdb51b2f61d26b2540716628d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"5.4.0.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20 GbE Multifunction Driver version 7.13.165.0 or greater is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c","SWKey":"evbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.13.165.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE QLogic NX2 Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QlNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bfba60117d4940ec81066b8b7a","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","U30","U40","U39"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp068638.exe","SHA1Sum":"b131f072e1418aecdca2ade8cfe75d27a422ce74","SHA256Sum":"863210e5ac6f4761322dce27b70e425e4a7ad009cf478737edf21f2c6348b71b","SHA512Sum":"89f77a5638da0cffa4af5ddb5a54af61874c3a7dfb8a0a20f60c2ab9ec383c334e49ed5025d87263b14198b1acca7a56e7ae31b2ef4eb27d2fd278ca4c320e56"}],"ComponentSizeInKB":3363,"CompsigList":["cp068638.compsig"],"FileList":["cp068638.xml","cpqsetup.exe","GPM1645ASAD5.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068638.exe","SHA1Sum":"b131f072e1418aecdca2ade8cfe75d27a422ce74","SHA256Sum":"863210e5ac6f4761322dce27b70e425e4a7ad009cf478737edf21f2c6348b71b","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b0168ec5461d4a2c884ee180be","SupportedDevices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL8CBA0HPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"cp073253.exe","SHA1Sum":"d798209bbade64f7e457b81750dd489981e44d10","SHA256Sum":"86e1f834e04fcf18d7e53111df0f313f34b710fd5680dafa750b5956417948fc","SHA512Sum":"cc018d05cf45f9b499807d65b3b0b3bd0958d16296f1088e552850b115b6a19ae9c190bec30f506bf9ca528a999f3cfd5d91565f5dc437891c7b0b5fe32298f9"}],"ComponentSizeInKB":4329,"CompsigList":["cp073253.compsig"],"FileList":["cp073253.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WVL8CBA0HPD3.rel"],"Name":"cp073253.exe","SHA1Sum":"d798209bbade64f7e457b81750dd489981e44d10","SHA256Sum":"86e1f834e04fcf18d7e53111df0f313f34b710fd5680dafa750b5956417948fc","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWRTD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d15c567fcce044b199a4a8c002","SupportedDevices":["4d2340a5-3042-3830-3030-304a57525444"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-24fe569b72-HPD6-2.1.x86_64.rpm","SHA1Sum":"c9b67f99ef66a6d0194dbefc1a648dc4d989d938","SHA256Sum":"482737fb747160512f4141175bfaabb9a9b5983492ce8580bc8251b8ab38dec8","SHA512Sum":"2802c4b0f0dd88b69a28af4b0c409a4cb1343a2dfc7d1bc3510d9e5d42fa48c66fa7818309d6b2eb4abf1bff5d6a8f0390a3f741cebb8befd76b18ced54f2e16"}],"ComponentSizeInKB":4998,"CompsigList":["firmware-hdd-24fe569b72-HPD6-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/CP068865.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/TA15SEN0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068865.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068865.scexe"],"Name":"firmware-hdd-24fe569b72-HPD6-2.1.x86_64.rpm","SHA1Sum":"c9b67f99ef66a6d0194dbefc1a648dc4d989d938","SHA256Sum":"482737fb747160512f4141175bfaabb9a9b5983492ce8580bc8251b8ab38dec8","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8743e3c43b1a4290be02278153","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52004TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d1cf327bc4_0HPG4-1.1_amd64.deb","SHA1Sum":"b442b0fd46686a36101aea7693758f008478d25f","SHA256Sum":"3e58b1a58062ecc55b8e25d3618135f28c67615b1b2f8f0c041fe376fba8aaf2","SHA512Sum":"b4ee5a7b3ed468b6e81a4551a1c46612707531ad4ed85e2ba9b2f1e2c0fd35db18e22f9827f5f087772a0a357941bc30850b59b35b9f5461e73a7ebee2db2ae8"}],"ComponentSizeInKB":3574,"CompsigList":["firmware-hdd-d1cf327bc4_0HPG4-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/CP072237.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/M52004TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072237.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072237.scexe"],"Name":"firmware-hdd-d1cf327bc4_0HPG4-1.1_amd64.deb","SHA1Sum":"b442b0fd46686a36101aea7693758f008478d25f","SHA256Sum":"3e58b1a58062ecc55b8e25d3618135f28c67615b1b2f8f0c041fe376fba8aaf2","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3330-3834-30475753584c"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK003840GWSXL Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK003840GWSXL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0eaa9b97953a460da7fbe706dc","SupportedDevices":["562340a5-304b-3330-3834-30475753584c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960KXAVL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304b5841564c","Version":"HPK5"},{"DeviceName":"VO001920KXAVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b58415650","Version":"HPK5"},{"DeviceName":"VO003840KXAVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b58415651","Version":"HPK5"},{"DeviceName":"VO007680KXAVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b58415652","Version":"HPK5"},{"DeviceName":"MO000800KXAVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304b5841564e","Version":"HPK5"},{"DeviceName":"MO001600KXAVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b58415654","Version":"HPK5"},{"DeviceName":"MO003200KXAVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b58415655","Version":"HPK5"},{"DeviceName":"MO006400KXAVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE80X0AHPK5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b58415656","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-035a863453_0HPK5-2.1_amd64.deb","SHA1Sum":"e2f60cbc70f4711ae0da4651d599cfb9c151b6e7","SHA256Sum":"38804b9b07d4e3637e4c2888903fa5e3e2ad1adb58f2d34ad92e8730600a6d38","SHA512Sum":"06ede65219c4a4680c7e4022ccc36b72f8d9c6087326086dd52440aef3f5e0a08f061e9c8f1493e7fc2d791f6498f48ddd1e48eb269a2612f6ea564db3a3e1f0"}],"ComponentSizeInKB":3597,"CompsigList":["firmware-hdd-035a863453_0HPK5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/CP071753.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/KPE80X0AHPK5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071753.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-035a863453-HPK5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071753.scexe"],"Name":"firmware-hdd-035a863453_0HPK5-2.1_amd64.deb","SHA1Sum":"e2f60cbc70f4711ae0da4651d599cfb9c151b6e7","SHA256Sum":"38804b9b07d4e3637e4c2888903fa5e3e2ad1adb58f2d34ad92e8730600a6d38","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304b5841564c","562340a5-304f-3130-3932-304b58415650","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656"],"TypeOfChange":"1","Version":"HPK5"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO000960KXAVL, VO001920KXAVP, VO003840KXAVQ, VO007680KXAVR, MO000800KXAVN, MO001600KXAVT, MO003200KXAVU and MO006400KXAVV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"VO000960KXAVL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO001920KXAVP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KXAVQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KXAVR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO000800KXAVN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KXAVT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KXAVU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KXAVV","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_137dd96e196d4c1aaf24f632ab","SupportedDevices":["562340a5-304f-3030-3936-304b5841564c","4d2340a5-304f-3030-3830-304b5841564e","4d2340a5-304f-3130-3630-304b58415654","4d2340a5-304f-3330-3230-304b58415655","4d2340a5-304f-3630-3430-304b58415656","562340a5-304f-3330-3834-304b58415651","562340a5-304f-3730-3638-304b58415652","562340a5-304f-3130-3932-304b58415650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072313.zip","SHA1Sum":"cef9d3cfa8a6b3bb071c4b8c65e28be69155f43a","SHA256Sum":"6fe7e439161d0677d1eefc4719265c0cc291fa3e3d05db187c5b1575aec97800","SHA512Sum":"5ed3fda4ee745040169544cfeb28962cbf0951f5dbf22c4cfbacb8a0df34756e8eff0e88aa476269aa19a04b885de5fbe561e24120a6821bc7d92ce5e7d438a9"}],"ComponentSizeInKB":304,"CompsigList":["cp072313.compsig"],"FileList":["/cp072313.xml","/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.zip","/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.zip/index.xml","/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.zip/vib20/i40en/INT_bootbank_i40en_2.12.1.0-1OEM.800.1.0.20613240.vib","/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/i40en-6988286028517542000.xml","/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Intel-i40en_2.12.1.0-1OEM.800.1.0.20613240.xml"],"Name":"cp072313.zip","SHA1Sum":"cef9d3cfa8a6b3bb071c4b8c65e28be69155f43a","SHA256Sum":"6fe7e439161d0677d1eefc4719265c0cc291fa3e3d05db187c5b1575aec97800","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"i40en","Version":"2.12.1.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE Intel i40en Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-i40en:2.12.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.12.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_370b2d2139f745e0903c63db50","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U36","U43","U41","U33","U44","A47","A48","U47","U37","A46","U47","U38","U38","U48","02020001","03020101","A42","U56","U61","U60","U64","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-18e328f036-HPG8-6.1.x86_64.rpm","SHA1Sum":"b0861590d648bbc28cd178db74a87c639a8e661a","SHA256Sum":"6bd5e6a503912a573d4fc2d1aaf337f72a587164765cbdd09f03af8b89a9efba","SHA512Sum":"6720c6c8d1f2ab9505927e9c33a0b44b74492b69a6f23d69e17537c13f7be6263aff17187ce4c17cfac1655da6c239439a55cd469f4a5cd4e55b6afbf9743c0d"}],"ComponentSizeInKB":5751,"CompsigList":["firmware-hdd-18e328f036-HPG8-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/CP068936.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/SCIMARRNETG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068936.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068936.scexe"],"Name":"firmware-hdd-18e328f036-HPG8-6.1.x86_64.rpm","SHA1Sum":"b0861590d648bbc28cd178db74a87c639a8e661a","SHA256Sum":"6bd5e6a503912a573d4fc2d1aaf337f72a587164765cbdd09f03af8b89a9efba","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4a2cf298e2444835a79f0b2da8","SupportedDevices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072689.exe","SHA1Sum":"6e895d128ccd0db821f5243c1b8e696adbcdbaff","SHA256Sum":"b3623bdcaeb0971731551a6d44a50c3bd2adc55e411f4290b5bec7932bf59683","SHA512Sum":"3380f664f09b8f9384c3c183d706496188d792a8c1e5ba748f8f2d5d96522c4eb60f3bead14a08df74d999e2568a49a06ed9418b21a64fed83f5b3a0ec93c7b4"}],"ComponentSizeInKB":1097,"CompsigList":["cp072689.compsig"],"FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp072689.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp072689.exe","SHA1Sum":"6e895d128ccd0db821f5243c1b8e696adbcdbaff","SHA256Sum":"b3623bdcaeb0971731551a6d44a50c3bd2adc55e411f4290b5bec7932bf59683","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"238.1.110.0"}],"InstallationDependency":{},"Name":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ac1b1f6b49d74f72919cc7f6fc","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16c514e41593","a6b1a447-382a-5a4f-14e4-16c514e41592","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-181b14e4e124","a6b1a447-382a-5a4f-14e4-181b14e4e324","a6b1a447-382a-5a4f-14e4-16bd14e41593","a6b1a447-382a-5a4f-14e4-16bd14e41592","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-181b14e4e124","a6b1a447-382a-5a4f-14e4-181b14e4e324","a6b1a447-382a-5a4f-14e4-16bd14e41595","a6b1a447-382a-5a4f-14e4-16bd14e41594","a6b1a447-382a-5a4f-14e4-16bd14e41597","a6b1a447-382a-5a4f-14e4-16bd14e41596","a6b1a447-382a-5a4f-14e4-16c514e41595","a6b1a447-382a-5a4f-14e4-16c514e41594","a6b1a447-382a-5a4f-14e4-16c514e41597","a6b1a447-382a-5a4f-14e4-16c514e41596","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc14e416d8","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14e4-181914e41760","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14e4-16dc14e416d6","a6b1a447-382a-5a4f-14e4-16dc14e416d7","a6b1a447-382a-5a4f-14e4-16dc14e41593","a6b1a447-382a-5a4f-14e4-16dc14e41592","a6b1a447-382a-5a4f-14e4-181914e4e124","a6b1a447-382a-5a4f-14e4-181914e4e324","a6b1a447-382a-5a4f-14e4-16c114e41593","a6b1a447-382a-5a4f-14e4-16c114e41592","a6b1a447-382a-5a4f-14e4-181914e4e124","a6b1a447-382a-5a4f-14e4-181914e4e324","a6b1a447-382a-5a4f-14e4-16c114e41595","a6b1a447-382a-5a4f-14e4-16c114e41594","a6b1a447-382a-5a4f-14e4-16c114e41597","a6b1a447-382a-5a4f-14e4-16c114e41596","a6b1a447-382a-5a4f-14e4-16dc14e41595","a6b1a447-382a-5a4f-14e4-16dc14e41594","a6b1a447-382a-5a4f-14e4-16dc14e41597","a6b1a447-382a-5a4f-14e4-16dc14e41596","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180814e41599","a6b1a447-382a-5a4f-14e4-180814e41598","a6b1a447-382a-5a4f-14e4-180914e41599","a6b1a447-382a-5a4f-14e4-180914e41598","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180614e41751","a6b1a447-382a-5a4f-14e4-180614e41599","a6b1a447-382a-5a4f-14e4-180614e41598","a6b1a447-382a-5a4f-14e4-180714e41599","a6b1a447-382a-5a4f-14e4-180714e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14E4-180800000000","a6b1a447-382a-5a4f-14E4-181B00000000","a6b1a447-382a-5a4f-14E4-180900000000","a6b1a447-382a-5a4f-14E4-181B00000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U39","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","H10","H10","H10","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072277.exe","SHA1Sum":"59624ac21535a4e411e91e8ad72a19655fdcf3d6","SHA256Sum":"b78ac3d986345cf736cba0d7a1b61c962fb711e5783befc1098e4a047a76b1c9","SHA512Sum":"5b333868629ae489b21d132b30e24dfdba4418614a04ef5c422962546dead2399e9cfda6b7d4b34895a9b6e2eb44e0f730154fbe733ff51ec6710fb8ee8a4a06"}],"ComponentSizeInKB":1404,"CompsigList":["cp072277.compsig"],"FileList":["cp072277.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"Name":"cp072277.exe","SHA1Sum":"59624ac21535a4e411e91e8ad72a19655fdcf3d6","SHA256Sum":"b78ac3d986345cf736cba0d7a1b61c962fb711e5783befc1098e4a047a76b1c9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.19.113.0"}],"InstallationDependency":{},"Name":"HPE Intel iavf Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_eaba41d9f2bb4aeab24bbf3918","SupportedDevices":["a6b1a447-382a-5a4f-8086-37CD15900000","a6b1a447-382a-5a4f-8086-37cd80860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-154c103c0000"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"CP070983.zip","SHA1Sum":"dbdf5b2b0aa1922e33b00ce32f4e12c0eb02cc40","SHA256Sum":"c7cff4643fe45fc1d87475bd32e358bbe45b15a866f9b3ff53da4bece870c313","SHA512Sum":"aae0430fa0ba2ccbfdf95924449fa8b22cdc7999a1ca88315a174007dd437705a25e5f6f208a4932580693c19b8c7f188ada10769b35b552cf10362f525883a1"}],"ComponentSizeInKB":18464,"CompsigList":["CP070983.compsig"],"FileList":["/CP070983_BUILD_2.data","/CP070983.vmexe64","/CP070983.vmfile","/CP070983_VMw.zip","/CP070983.xml","/payload.json","/CP070983_VMw.zip/index.xml","/CP070983_VMw.zip/vendor-index.xml","/CP070983_VMw.zip/metadata.zip","/CP070983_VMw.zip/vib20/CP070983/HPE_bootbank_CP070983_HPD2.2-8.0.0.20613240.vib","/CP070983_VMw.zip/metadata.zip/vendor-index.xml","/CP070983_VMw.zip/metadata.zip/vmware.xml","/CP070983_VMw.zip/metadata.zip/vibs/CP070983--2246090989153402999.xml","/CP070983_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070983_HPD2.2-8.0.0.20613240.xml"],"Name":"CP070983.zip","SHA1Sum":"dbdf5b2b0aa1922e33b00ce32f4e12c0eb02cc40","SHA256Sum":"c7cff4643fe45fc1d87475bd32e358bbe45b15a866f9b3ff53da4bece870c313","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP070983","Version":"HPD2.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a3b8ba904ca745178e3f0fb5c3","SupportedDevices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-cfd7436fcc-HPD4-5.1.x86_64.rpm","SHA1Sum":"4056985b475febfd2df1eb4cb7fbb571f9f25503","SHA256Sum":"05ade18957696c64389159ec24bcad642b6468fe5fb58c0cc1db68d77c6e69c4","SHA512Sum":"96d3d3a87a43b6ac98be6452f27532ddb8eb2984d6628700844843936bd4b5632f4893ccf1618b42fede98f319a3b364f48104cffb7d4ace94a515c0b7b4b8f8"}],"ComponentSizeInKB":6351,"CompsigList":["firmware-hdd-cfd7436fcc-HPD4-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/CP068849.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/WLEBsssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068849.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068849.scexe"],"Name":"firmware-hdd-cfd7436fcc-HPD4-5.1.x86_64.rpm","SHA1Sum":"4056985b475febfd2df1eb4cb7fbb571f9f25503","SHA256Sum":"05ade18957696c64389159ec24bcad642b6468fe5fb58c0cc1db68d77c6e69c4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWUDB Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_07622a2605684dfc8bb07322b6","SupportedDevices":["4d2340a5-3042-3431-3030-304a57554442"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp070636.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"firmware-microserverv2gen10plus_me-06.00.03.708-2.1.x86_64.rpm","SHA1Sum":"09be99fe750190cbe6a2e94801a84989039c750c","SHA256Sum":"b6013d4de0479f2d2ca14f385038f789deb26a2488c614c2fb33d595c7b2b86f","SHA512Sum":"7bf5a13f2d343e4c1a82adc496678f8a218e96ecab2032b45410afcb670cdad4409de14314ac92b287505e420bfdd4d67e73f0fb21eb299c43e99702c0e7810a"}],"ComponentSizeInKB":2398,"CompsigList":["firmware-microserverv2gen10plus_me-06.00.03.708-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/CP070638.xml","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/cp070636.compsig","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/cp070636.zip","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microserverv2gen10plus_me-06.00.03.708-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070638.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070638.scexe"],"Name":"firmware-microserverv2gen10plus_me-06.00.03.708-2.1.x86_64.rpm","SHA1Sum":"09be99fe750190cbe6a2e94801a84989039c750c","SHA256Sum":"b6013d4de0479f2d2ca14f385038f789deb26a2488c614c2fb33d595c7b2b86f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3af67b67e9344b4da2f1bbc2d4","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U64"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E4159D","Version":"20.38.51"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41591","Version":"20.38.51"},{"DeviceName":"Broadcom BCM5719 Ethernet 1Gb 4-port Base-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165714E41590","Version":"20.38.51"},{"DeviceName":"Broadcom BCM5720 Ethernet 1Gb 2-port BASE-T LOM Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F14E4159C","Version":"20.38.51"}]},"Files":[{"Checksum":[{"Filename":"cp072708.exe","SHA1Sum":"d89e4507ec7dd259f2477d463a938942f391d61e","SHA256Sum":"cf963fcb1b385a6716a644127ef92be25293dc88ce74f76a64e87c06d4c66bd1","SHA512Sum":"61de06f23143de0bef0dc1a7b533bdbe2f1b108648a66b0264c9e1b3f42908b86588757fc05e040e63e456817c5c6df78772a687996f0bb10fd38e776774ea9b"}],"ComponentSizeInKB":7488,"CompsigList":["cp072708.compsig"],"FileList":["bcmnicfwupg.exe","BMAPIa.dll","cp072708.xml","cpqsetup.exe","FW/","FW/BCM5719-LOM-4x1G-14E4-1657-14E4-159D.BIN","FW/BCM5719A1907HC-4x1G-14E4-1657-14E4-1591.BIN","FW/BCM5719N1905HC-4x1G-14E4-1657-14E4-1590.BIN","FW/BCM5720-LOM-2x1G-14E4-165F-14E4-159C.BIN","FW/firmware.json","HPWinFwUpgLib.dll","ja/","ja/NICOFUT.chm","libeay32.dll","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp072708.exe","SHA1Sum":"d89e4507ec7dd259f2477d463a938942f391d61e","SHA256Sum":"cf963fcb1b385a6716a644127ef92be25293dc88ce74f76a64e87c06d4c66bd1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165714E4159D","a6b1a447-382a-5a4f-14E4-165714E41591","a6b1a447-382a-5a4f-14E4-165714E41590","a6b1a447-382a-5a4f-14E4-165F14E4159C"],"TypeOfChange":"1","Version":"5.4.8.0"}],"InstallationDependency":{},"Name":"Broadcom NX1 Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BcmNicFwUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8974baef489c42ce94e8bda23f","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U58","U58","H10","H10","U47","U46","A42","A42","A43","U46","03030202","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A41_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072015.exe","SHA1Sum":"36f7623b8a3d3a39eaf71d40fe6818450ba9b4be","SHA256Sum":"90f58d5eb030cebc51fb927c78ffad26b7e2e47513141d3ea47a2d223ead21d2","SHA512Sum":"f9fe215c5504ad749ae882de011d49f32989efcee3bf261564901c5a37659d1a32f0f201a1d3461f2fe551453c374e833c60c269cb0d00b264580ee1067b5026"}],"ComponentSizeInKB":17738,"CompsigList":["cp072015.compsig"],"FileList":["A41_3.80_05_28_2026.signed.flash","cp072015.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp072015.exe","SHA1Sum":"36f7623b8a3d3a39eaf71d40fe6818450ba9b4be","SHA256Sum":"90f58d5eb030cebc51fb927c78ffad26b7e2e47513141d3ea47a2d223ead21d2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325 Gen10 (A41) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dc36418e9a5c444ea31a54d413","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A41"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051643.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Files":[{"Checksum":[{"Filename":"cp069596.exe","SHA1Sum":"b705b49ad24b0ac316df237c1975f14227b16910","SHA256Sum":"632968341a6337fbeebb4024a75965b644617e6e22c3a40d3b9af01ef29b49a1","SHA512Sum":"f3d9c569d86ba290b27e9e467d4a472c9312cb322da76a5445e64397a679dafdb893e280a521797ee311bfcb98fc2765c08b5d2de8b31a7d075955dd30e351f9"}],"ComponentSizeInKB":8840,"CompsigList":["cp069596.compsig"],"FileList":["cp051643.compsig","cp051643.zip","cp069596.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp069596.exe","SHA1Sum":"b705b49ad24b0ac316df237c1975f14227b16910","SHA256Sum":"632968341a6337fbeebb4024a75965b644617e6e22c3a40d3b9af01ef29b49a1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"InstallationDependency":{},"Name":"Online ROM Flash for Windows x64 -  HPE Gen10 Plus Innovation Engine Firmware  for HPE Gen10 Plus Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:sd:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_abd642129a204ef7a157ea1218","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","H10","U56","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-805abb7e9c_85032G00-2.1_amd64.deb","SHA1Sum":"e851c54c4a156d727bc1b4b08a473578bebab14d","SHA256Sum":"134c35b1c8178070c073adce920491d21222f6a1069b7c45a55172f1ea086d61","SHA512Sum":"aa39b6bc6f7973cd1ce5f830233c458b75729b01ce86433e276d1d76eaa02bde514f245728942333845a86c8b53b9ef453f543795f1c4e00ecfe95032e8b8d28"}],"ComponentSizeInKB":3933,"CompsigList":["firmware-hdd-805abb7e9c_85032G00-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/85032G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/CP071757.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071757.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071757.scexe"],"Name":"firmware-hdd-805abb7e9c_85032G00-2.1_amd64.deb","SHA1Sum":"e851c54c4a156d727bc1b4b08a473578bebab14d","SHA256Sum":"134c35b1c8178070c073adce920491d21222f6a1069b7c45a55172f1ea086d61","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4003352b072144f088efb2cf49","SupportedDevices":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":0,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_322.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.22"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_322.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.22"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_322.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.22"}]},"Files":[{"Checksum":[{"Filename":"ilo5_322.fwpkg","SHA1Sum":"70a69b05570dfc367b46ef758bddfdfdf716a9d8","SHA256Sum":"5cc0c9d2e5b0575a1e1e1c5c875c545921f503df10127731eb4666b6d32e3ae7","SHA512Sum":"7560ce36e69e4eab8b95d780a8a6f393b6315c119aace7bfee04bd73327b61276cd548cb07d3a9d20d2d2a0fb7ceafe7c6ecb0cd5f170bdad09cccad1074c9bd"}],"ComponentSizeInKB":32801,"CompsigList":[],"FileList":["ilo5_322.bin","ilo5_322.xml","payload.json","readme.txt"],"Name":"ilo5_322.fwpkg","SHA1Sum":"70a69b05570dfc367b46ef758bddfdfdf716a9d8","SHA256Sum":"5cc0c9d2e5b0575a1e1e1c5c875c545921f503df10127731eb4666b6d32e3ae7","SoftwarePlatforms":[],"TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.22"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2a89052f9bfc4e7ab480b66866","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Linux","Version":["24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U51","A47","A48","U40","U39","U47","U45","U24","U37","A46","U47","U38","U38","U48","O43","A45","U38","U38","U38","U47","U47","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U40","U50","U39","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U56","H10","U61","U60","U64","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"cp068751.exe","SHA1Sum":"a65fb6986f02b1e011b5913383dc14d4d0756cea","SHA256Sum":"53ba1ab716f10ca27ae636bb2241d1b2ca7b543eef93f44d54354b96add09501","SHA512Sum":"5641bd3c58669081d3af2e668b54abdc105d62a3cb23beac91a053657b7a3b1922df692a4d5b68efb9a0fcedae16594e9923d4af25610bdcc33d492226735242"}],"ComponentSizeInKB":3905,"CompsigList":["cp068751.compsig"],"FileList":["BCHPC17M.bin","cp068751.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068751.exe","SHA1Sum":"a65fb6986f02b1e011b5913383dc14d4d0756cea","SHA256Sum":"53ba1ab716f10ca27ae636bb2241d1b2ca7b543eef93f44d54354b96add09501","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e5d44479dcd241aa80b77c5e9a","SupportedDevices":["452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42","452340a5-304f-3030-3430-304a57444b50","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3830-304a57444b56"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08SDAeD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a575a5651","Version":"HPD3"},{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08SDAeD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a575a5652","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Toshiba_MG08Air_TAMG08SDAeD3.fwpkg","SHA1Sum":"cb4c724156dd68463a38c4c5237d5a89304ec792","SHA256Sum":"3a7bc5c43a9b028ffdcfac3fd987424486bc86afd1de644f403f99c8ded78ef7","SHA512Sum":"fe3494fa430531ab7f031fe6f71676762dc86f3e98cad49c4e007344a4fd3ce1524eab2f5c230098929efae7e1ae5d5f47f9f54c80cff9f68ae63ceb6b0b4ab7"}],"ComponentSizeInKB":1281,"CompsigList":[],"FileList":["payload.json","Toshiba_MG08Air_TAMG08SDAeD3.HPb","Toshiba_MG08Air_TAMG08SDAeD3.xml"],"Name":"Toshiba_MG08Air_TAMG08SDAeD3.fwpkg","SHA1Sum":"cb4c724156dd68463a38c4c5237d5a89304ec792","SHA256Sum":"3a7bc5c43a9b028ffdcfac3fd987424486bc86afd1de644f403f99c8ded78ef7","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a575a5651","4d2340a5-3042-3830-3030-304a575a5652"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MB006000JWZVQ and MB008000JWZVR","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWZVQ","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB008000JWZVR","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6927e5439b7746e3bda2359045","SupportedDevices":["4d2340a5-3042-3630-3030-304a575a5651","4d2340a5-3042-3830-3030-304a575a5652"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"b5f7702fda1acbb0280e468ca52f02455ecd10cf","SHA256Sum":"a1a1a2726c5b4d245532cd975b5442bbba8641cb96988a928a3bafa8bc8a0c8a","SHA512Sum":"b09cdc80e7c7dd03ead36536c570626153e9899d6c272c8faa229c2587e01abb5af010d4dfab7be811de41f3406e7b226884f884eb7327e9bea1d25126cd10e3"}],"ComponentSizeInKB":4911,"CompsigList":["qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/6.4.0-150600.21-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"Name":"qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"b5f7702fda1acbb0280e468ca52f02455ecd10cf","SHA256Sum":"a1a1a2726c5b4d245532cd975b5442bbba8641cb96988a928a3bafa8bc8a0c8a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0818951042fb470fada2ce7d5c","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b04df66fe9_0HPD5-2.1_amd64.deb","SHA1Sum":"29b59dc129b0321951dc22dee86f078e17d7bc18","SHA256Sum":"8cc2a8758b8a728ff6d996984a13ac8e0cc2804bf0c8f425708d239d156505e3","SHA512Sum":"69bbafe84538d4ca6165c89e0b9e5934f3f3012984bcec9395dfe2ec70f54afca04ff21075d0b8efca8cc307182ddc92993d7282b1a16c674cc6afce6877b105"}],"ComponentSizeInKB":4784,"CompsigList":["firmware-hdd-b04df66fe9_0HPD5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/CP071780.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/SCIMARBPESD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071780.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071780.scexe"],"Name":"firmware-hdd-b04df66fe9_0HPD5-2.1_amd64.deb","SHA1Sum":"29b59dc129b0321951dc22dee86f078e17d7bc18","SHA256Sum":"8cc2a8758b8a728ff6d996984a13ac8e0cc2804bf0c8f425708d239d156505e3","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f9efda9935f14c56a04a9de437","SupportedDevices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c7df7ceedb_0HPD9-2.1_amd64.deb","SHA1Sum":"596673c08819ebfe58be4168e182f7957324fbed","SHA256Sum":"a84368307e278f821b417615d6b3390d0f920e98725b119916b0d92ce099e585","SHA512Sum":"eca90bf838e3ff3bc85a6b8a8c52b1c426fc293f52d518eac38b8f8e489d33cd53f908ef3738a793fa5cd187c65a361328e0b4a8167e8af19138925f8cc57db9"}],"ComponentSizeInKB":3464,"CompsigList":["firmware-hdd-c7df7ceedb_0HPD9-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/CP071706.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/TA14SXe0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071706.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-c7df7ceedb-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071706.scexe"],"Name":"firmware-hdd-c7df7ceedb_0HPD9-2.1_amd64.deb","SHA1Sum":"596673c08819ebfe58be4168e182f7957324fbed","SHA256Sum":"a84368307e278f821b417615d6b3390d0f920e98725b119916b0d92ce099e585","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000900JWHPK and EH000600JWHPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c89b12216de74625b40198f036","SupportedDevices":["452340a5-3048-3030-3630-304a57485048","452340a5-3048-3030-3930-304a5748504b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021d","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021d","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021f","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021f","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021f","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021f","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809015900220","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021b","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021b","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021b","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021b","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021a","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80801590021a","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80841590021a","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80901590021a","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021d","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021f","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f015900220","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021b","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f01590021a","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002bd","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8090159002bd","Version":"8.65.31"},{"DeviceName":"HPE Qlogic FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_hp_ah_mbi_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f0159002bd","Version":"8.65.31"}]},"Files":[{"Checksum":[{"Filename":"ql_hp_ah_mbi_8.65.31_pldm.fwpkg","SHA1Sum":"f197299da2ba78e35afdea80661c2c541c52323d","SHA256Sum":"fa8bcee8cb9c865e8129ef50676938cb46f414e65445a1f01d9d64dba43fa873","SHA512Sum":"9b341f4683773928af208dcd72a0184969ed4b3958803e109d46a4997b085dca40d81aaafc01d493bf311a0a216dc005e87d118d296b7116e3d5aae9c37d9380"}],"ComponentSizeInKB":1784,"CompsigList":[],"FileList":["payload.json","ql_hp_ah_mbi_8.65.31_pldm.HPb","ql_hp_ah_mbi_8.65.31_pldm.xml"],"Name":"ql_hp_ah_mbi_8.65.31_pldm.fwpkg","SHA1Sum":"f197299da2ba78e35afdea80661c2c541c52323d","SHA256Sum":"fa8bcee8cb9c865e8129ef50676938cb46f414e65445a1f01d9d64dba43fa873","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-80801590021f","a6b1a447-382a-5a4f-1077-80841590021f","a6b1a447-382a-5a4f-1077-80901590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-80801590021b","a6b1a447-382a-5a4f-1077-80841590021b","a6b1a447-382a-5a4f-1077-80901590021b","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80801590021a","a6b1a447-382a-5a4f-1077-80841590021a","a6b1a447-382a-5a4f-1077-80901590021a","a6b1a447-382a-5a4f-1077-80f01590021d","a6b1a447-382a-5a4f-1077-80f01590021f","a6b1a447-382a-5a4f-1077-80f015900220","a6b1a447-382a-5a4f-1077-80f01590021b","a6b1a447-382a-5a4f-1077-80f01590021a","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-80f0159002bd"],"TypeOfChange":"1","Version":"8.65.31"}],"InstallationDependency":{},"MinimumActiveVersion":"8.55.12","Name":"HPE QLogic FastLinQ Firmware Package for Arrowhead adapters","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"NIC_FLQ_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_02987985902f44298f76cb2f67","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.38.51"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-2.44.0-1.1.x86_64.rpm","SHA1Sum":"d8632e1e34a9c1c7b5fe8364f9162b6b45d62b1b","SHA256Sum":"8c26321bbba7d857ea15fdfad9bc6839e73cad4bf8883cf9d9ba2c95dddc4652","SHA512Sum":"7125499712ccf9cf9aa0519da29ee6e3519f962cf6ccb5a5d16f8bef3c44478fdab07eb25ca60bb53faa625c6f00c299eaff5242c0eac7429c18af36295e18be"}],"ComponentSizeInKB":6276,"CompsigList":["firmware-nic-bcm-2.44.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/CP072703.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/CP072703.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/deps/libs/libbmapi_x64.so.6","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/nic_fw/331FLR-4x1G-14E4-1657-103C-169D.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/nic_fw/331T-4x1G-14E4-1657-103C-3383.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/nic_fw/331i-4x1G-14E4-1657-103C-22BE.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/nic_fw/332T-2x1G-14E4-165F-103C-1786.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/nic_fw/332i-2x1G-14E4-165F-103C-22E8.BIN","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-2.44.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072703.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072703.scexe"],"Name":"firmware-nic-bcm-2.44.0-1.1.x86_64.rpm","SHA1Sum":"d8632e1e34a9c1c7b5fe8364f9162b6b45d62b1b","SHA256Sum":"8c26321bbba7d857ea15fdfad9bc6839e73cad4bf8883cf9d9ba2c95dddc4652","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"2.44.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"HPE Broadcom NX1 Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b7d35cfcd9aa4c2a98568dbd54","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.31"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.31"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.31"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.31"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.31"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.31"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-qlogic-nx2-2.38.0-1.1.x86_64.rpm","SHA1Sum":"0291ede9e855398e790fa9f3f00fb7ac46f1d9c5","SHA256Sum":"c1a44f28e6bd5c3f3bbec8a64e8334e9d638d48527c6b77f58e0eb869153e847","SHA512Sum":"a348d77578a084f2d14f94d629a493dd03fb5d29feb29918cff22985a1a4d06fb342a3a5d1e9b466e4ed52fa2b9d1dd0af41ba3aa1f019a99a00205cddd9105e"}],"ComponentSizeInKB":3203,"CompsigList":["firmware-nic-qlogic-nx2-2.38.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/CP072522.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/CP072522.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/nic_fw/hp_mbi_7.19.31.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-nx2-2.38.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072522.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072522.scexe"],"Name":"firmware-nic-qlogic-nx2-2.38.0-1.1.x86_64.rpm","SHA1Sum":"0291ede9e855398e790fa9f3f00fb7ac46f1d9c5","SHA256Sum":"c1a44f28e6bd5c3f3bbec8a64e8334e9d638d48527c6b77f58e0eb869153e847","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"2.38.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","DeviceGUID":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E3-Ethernet-iSCSI-FCoE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.0.251.0-1OEM.700.1.0.15843807"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","SWKey":"qfle3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.4.51.0-1OEM.700.1.0.15843807"}]}]}]},"Name":"HPE QLogic NX2 Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_NX2","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7dc29fb9ebf54d608e3b516011","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","16.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","U30","U40","U39"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A46_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a46-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"4da91d6431aad75c7e2cbd313b7cc9132f3f71da","SHA256Sum":"92e2d7991931131cd3f87c7cf56b394d568b6a7864cbd4f6432dc8c6e6623488","SHA512Sum":"9db8dd331c0e88cbf3ff833c0e6b304f467cee71d4b5279b7a566f2d350682f90df7164123744b0ebefd616547fdc0406558adb38926520604a9ec639a167876"}],"ComponentSizeInKB":33254,"CompsigList":["firmware-system-a46-4.04_2026_04_02-1.1.x86_64_part1.compsig","firmware-system-a46-4.04_2026_04_02-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/A46_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/CP071518.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a46-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071518.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071518.scexe"],"Name":"firmware-system-a46-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"4da91d6431aad75c7e2cbd313b7cc9132f3f71da","SHA256Sum":"92e2d7991931131cd3f87c7cf56b394d568b6a7864cbd4f6432dc8c6e6623488","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant XL225n Gen10 Plus (A46) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f9594d6b3d794d5196464923ac","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","10.0","9.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A46"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070976.zip","SHA1Sum":"213b224e0234e326ff054d868a39f608bd629a30","SHA256Sum":"87b69eecbc44a2517a209f6d81806ae767f03e63c27c4bea63ceddff13d72ac0","SHA512Sum":"5b6b13db33c9818fdf8cd191807519cdfc47fdabb608c176fd1add3d48f1bdb59c06d4041ac037a8d6d44c242489ee91518be3837e95387dc624f8c92df75551"}],"ComponentSizeInKB":20121,"CompsigList":["CP070976.compsig"],"FileList":["/CP070976_BUILD_1.data","/CP070976.vmexe64","/CP070976.vmfile","/CP070976_VMw.zip","/CP070976.xml","/payload.json","/CP070976_VMw.zip/index.xml","/CP070976_VMw.zip/vendor-index.xml","/CP070976_VMw.zip/metadata.zip","/CP070976_VMw.zip/vib20/CP070976/HPE_bootbank_CP070976_HPD6.1-8.0.0.20613240.vib","/CP070976_VMw.zip/metadata.zip/vendor-index.xml","/CP070976_VMw.zip/metadata.zip/vmware.xml","/CP070976_VMw.zip/metadata.zip/vibs/CP070976-8380625430916530490.xml","/CP070976_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070976_HPD6.1-8.0.0.20613240.xml"],"Name":"CP070976.zip","SHA1Sum":"213b224e0234e326ff054d868a39f608bd629a30","SHA256Sum":"87b69eecbc44a2517a209f6d81806ae767f03e63c27c4bea63ceddff13d72ac0","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070976","Version":"HPD6.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB002000JYDNE and MB004000JYDPB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_08a2656ab1a144ed9a9cde7799","SupportedDevices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069696.exe","SHA1Sum":"094a78dd7721ba6aa3a4f78dea138aaddb07a73d","SHA256Sum":"734da7bf563045929b968b4bd2e5feff0d03f704fa1edc1c10bea898f32b54c2","SHA512Sum":"208ed479c5b47f1b08ab93d246091ec820c9b8fc38dd6f1c3de2869f3be11c2506bc65c7924f4f5db4b0909b175cc553c712a98815ec185c1614c8e24a186ec8"}],"ComponentSizeInKB":610,"CompsigList":["cp069696.compsig"],"FileList":["cp069696.xml","cpqsetup.exe","installer.dll","pnp/","pnp/NULL_HECI.cat","pnp/NULL_HECISystem.inf","pnp/RocketLake.cat","pnp/RocketLakeSystem.inf","pnp/TigerLakePCH-H.cat","pnp/TigerLakePCH-HSystem.inf"],"Name":"cp069696.exe","SHA1Sum":"094a78dd7721ba6aa3a4f78dea138aaddb07a73d","SHA256Sum":"734da7bf563045929b968b4bd2e5feff0d03f704fa1edc1c10bea898f32b54c2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19886.8592"}],"InstallationDependency":{},"Name":"Identifiers for Intel Xeon E-23xx Processor for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_eb805e4703474f4d9f67ea754a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399","10.0","10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U61","U60","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H08","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H08_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000221","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-h08-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"f5b4ec0d2b478b52e431c97887cced5a41580af2","SHA256Sum":"27ca64f65dcdcb986d39c948fc860464638819f68aec8860e754a23b35e92666","SHA512Sum":"065c27af98cd5abc99aa510cefee721d0e0620cb622dd44727ae4d533144067b23866645d3960caf29a00e0711899e95642b4bef1ae7b331aa7b75e416c72d66"}],"ComponentSizeInKB":10935,"CompsigList":["firmware-system-h08-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.70_2026_08_19-1.1/CP073192.xml","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.70_2026_08_19-1.1/H08_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-h08-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073192.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073192.scexe"],"Name":"firmware-system-h08-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"f5b4ec0d2b478b52e431c97887cced5a41580af2","SHA256Sum":"27ca64f65dcdcb986d39c948fc860464638819f68aec8860e754a23b35e92666","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant e910/e910t Server Blade (H08)","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H08","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aaaf449d40474050848ffcb9b8","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","15.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR100/EN 100Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30069","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","SHA1Sum":"a85e6a8d2bc9643ee7effbae5676e36a29391947","SHA256Sum":"9336c451573a77ece275fccdc388944e4515e15ac7686f9c0a7bc596d7f5a453","SHA512Sum":"921e58d41356a223c86c65eda3ae0ecd55296435c2478a795a37a810deb70b18a3a97497ac6dd52a2563c4d487f694eafd8601fbeee742d33ae17b71e0b3b497"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.signed","20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653105A-ECA_HPE_Ax.pldm.fwpkg","SHA1Sum":"a85e6a8d2bc9643ee7effbae5676e36a29391947","SHA256Sum":"9336c451573a77ece275fccdc388944e4515e15ac7686f9c0a7bc596d7f5a453","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR100/Ethernet 100Gb 1-port QSFP56 PCIe4 x16 MCX653105A-ECAT Adapter : HPE part numbers P23665-B21 and P23665-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653105A-ECAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ec3d440efe554dd3a41ae6e2f4","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15b30069"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U54","U58","U58","U62","U63","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08SDAnD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a575a5655","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Toshiba_MG08Air_TAMG08SDAnD3.fwpkg","SHA1Sum":"af61cb6f5c2c9be89d5ba8195154580c88a87bcf","SHA256Sum":"5a3ffcc88bd314c603494722b942ccdc8cf8a9937fb230e0fa70f647d8a1628f","SHA512Sum":"44080d9266cd1d595e8996376f90a61e1d35aa6305c8210ac25cbb18b2ec570a5cc71ff630c778463b302b1e160d5b268badfeb282445b15936980078c561f07"}],"ComponentSizeInKB":1260,"CompsigList":[],"FileList":["payload.json","Toshiba_MG08Air_TAMG08SDAnD3.HPb","Toshiba_MG08Air_TAMG08SDAnD3.xml"],"Name":"Toshiba_MG08Air_TAMG08SDAnD3.fwpkg","SHA1Sum":"af61cb6f5c2c9be89d5ba8195154580c88a87bcf","SHA256Sum":"5a3ffcc88bd314c603494722b942ccdc8cf8a9937fb230e0fa70f647d8a1628f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a575a5655"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB004000JWZVU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWZVU","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cb947df2b7494b02a1ae11bb03","SupportedDevices":["4d2340a5-3042-3430-3030-304a575a5655"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3d97759111-HPDB-4.1.x86_64.rpm","SHA1Sum":"03e418dd9e18a64ca36a73dbe171e7f3025b27fb","SHA256Sum":"229c510bc0484c83a07d7565c164a30553463f4144cc94f6f51e23d39a39671c","SHA512Sum":"a71952a34d8f3227fcc874cf1a262cd2559637c1c3e7f045c229f93000755bf4e63b4d6fd0c5d1713713f387a4c5946e5c22f4edb1daadaa4986bb68d37a2f87"}],"ComponentSizeInKB":5794,"CompsigList":["firmware-hdd-3d97759111-HPDB-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/CP068928.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/SKESTNDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068928.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068928.scexe"],"Name":"firmware-hdd-3d97759111-HPDB-4.1.x86_64.rpm","SHA1Sum":"03e418dd9e18a64ca36a73dbe171e7f3025b27fb","SHA256Sum":"229c510bc0484c83a07d7565c164a30553463f4144cc94f6f51e23d39a39671c","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_de21450efdd548ebb29ded49e6","SupportedDevices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9475583fb5_0HPG1-2.1_amd64.deb","SHA1Sum":"0ba5d30da9df71e711e47b6ae51e152da7b5fbcd","SHA256Sum":"9cacf3d8a9e61810fc11b6dbae57781b5f6f7dcd93638ff79ae39cde396dccf4","SHA512Sum":"0d253d1a3d6301d3decabb5cc675e00f9f25623c908f12e6613d6820ad6973145e6ae14058627231e172143e4a929528fb3d74ca0fa08a68da73260024952dfc"}],"ComponentSizeInKB":4137,"CompsigList":["firmware-hdd-9475583fb5_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/CP071803.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/HPG1PM897.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071803.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-9475583fb5-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071803.scexe"],"Name":"firmware-hdd-9475583fb5_0HPG1-2.1_amd64.deb","SHA1Sum":"0ba5d30da9df71e711e47b6ae51e152da7b5fbcd","SHA256Sum":"9cacf3d8a9e61810fc11b6dbae57781b5f6f7dcd93638ff79ae39cde396dccf4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_58f15fdfecdf4addbbdd5ca7ed","SupportedDevices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4_OCP_5p0_NCSIwPLDMoMCTP_80021BCD.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-15938086000c","Version":"5.00"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXV4_OCP_5p0_NCSIwPLDMoMCTP_80021BCD.fwpkg","SHA1Sum":"14dff53d6c6736234a5cca87b34041bb59585585","SHA256Sum":"ec32d4f8f6c384ba3022267ea772d1d7718205aa1b0a63eb8980591cd1a30f83","SHA512Sum":"1c2e8cafa4f26fd6d8ed7ddf2da99f7a167e976ea812406e0f2157d5dca896c05edfd027a9c807e0d922778b9d13f0ff28edfacf381f905b50b46bf4778cb015"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_XXV4_OCP_5p0_NCSIwPLDMoMCTP_80021BCD.HPb","HPE_E810_XXV4_OCP_5p0_NCSIwPLDMoMCTP_80021BCD.xml","payload.json"],"Name":"HPE_E810_XXV4_OCP_5p0_NCSIwPLDMoMCTP_80021BCD.fwpkg","SHA1Sum":"14dff53d6c6736234a5cca87b34041bb59585585","SHA256Sum":"ec32d4f8f6c384ba3022267ea772d1d7718205aa1b0a63eb8980591cd1a30f83","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000c"],"TypeOfChange":"1","Version":"5.00"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7f7ad765f7484b5b80dd90b3ce","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-3052584b5243","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-3052584b5248","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-3052584b524b","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-3052584b5242","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-3052584b5244","Version":"HPD5"},{"DeviceName":"Seagate-LangeBP-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_LangeBP_SLNGBPHPESD5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-3052584b5245","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"Seagate_LangeBP_SLNGBPHPESD5.fwpkg","SHA1Sum":"5d23f1d1eb610c65d8e1cf830c95697d0d9a44e7","SHA256Sum":"9ac1efce4d549b300896d3d3ad59f812085601f3ddf1684475267e661136ff23","SHA512Sum":"db0e960bdae7cc10b6ea8e0eb29886f098e4728aba77e1f130441a8dfc4b66347a686cb728d4bfc8b729c7b39f05338bb4fe6e009301e91d28c2f0f3646ececd"}],"ComponentSizeInKB":2120,"CompsigList":[],"FileList":["payload.json","Seagate_LangeBP_SLNGBPHPESD5.HPb","Seagate_LangeBP_SLNGBPHPESD5.xml"],"Name":"Seagate_LangeBP_SLNGBPHPESD5.fwpkg","SHA1Sum":"5d23f1d1eb610c65d8e1cf830c95697d0d9a44e7","SHA256Sum":"9ac1efce4d549b300896d3d3ad59f812085601f3ddf1684475267e661136ff23","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3936-3052584b5243","4d2340a5-304f-3130-3932-3052584b5248","4d2340a5-304f-3330-3834-3052584b524b","562340a5-304f-3030-3936-3052584b5242","562340a5-304f-3130-3932-3052584b5244","562340a5-304f-3330-3834-3052584b5245"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO000960RXKRC, MO001920RXKRH, MO003840RXKRK, VO000960RXKRB, VO001920RXKRD and VO003840RXKRE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000960RXKRC","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001920RXKRH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003840RXKRK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RXKRB","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RXKRD","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RXKRE","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_698b806535e54899a0d8cfa4fa","SupportedDevices":["4d2340a5-304f-3030-3936-3052584b5243","4d2340a5-304f-3130-3932-3052584b5248","4d2340a5-304f-3330-3834-3052584b524b","562340a5-304f-3030-3936-3052584b5242","562340a5-304f-3130-3932-3052584b5244","562340a5-304f-3330-3834-3052584b5245"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"smartpqi-kmp-default-2.1.40-020.sles16sp0.x86_64.rpm","SHA1Sum":"23c65578412b38c463e951b9a77f9990a19a32a3","SHA256Sum":"2e6b2b1c44030b3beecb17c70e4bceeb93ff6b41ad0aa49493ab31172b3cbe15","SHA512Sum":"b9022534067369814e4415cf62edf25fa0760b1924ce9114ba4c8641ce496d7733ffd73cc2de43c2871cfc744b030d477c0369272a3396868e22582a0e03c262"}],"ComponentSizeInKB":112,"CompsigList":["smartpqi-kmp-default-2.1.40-020.sles16sp0.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/smartpqi.conf","./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"Name":"smartpqi-kmp-default-2.1.40-020.sles16sp0.x86_64.rpm","SHA1Sum":"23c65578412b38c463e951b9a77f9990a19a32a3","SHA256Sum":"2e6b2b1c44030b3beecb17c70e4bceeb93ff6b41ad0aa49493ab31172b3cbe15","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.40-020"}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 16 (64-bit)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3a719c2d70eb4fc585c6c7f552","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","U46","U46","A43","A42","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","I44","U60","U61","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","U71","U68","U68","U72","U68","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-cfd7436fcc_0HPD4-2.1_amd64.deb","SHA1Sum":"d68129c06981dbff7702e7006aa9ab89ffb2cb3e","SHA256Sum":"431ae7bb268bbd928c2d85763ae30f336aed84a0e2b1b8574441baed2b2eab7e","SHA512Sum":"b6cbcd713859a092ff9ed32d77d72dce8bf19fe96a278aad6cbe8826f9023e4f8fc4723149cd4125bf51b0a2ef74c9d5f872e39e9f04395eaf0949d0b75cca46"}],"ComponentSizeInKB":4727,"CompsigList":["firmware-hdd-cfd7436fcc_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/CP071739.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/WLEBsssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071739.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-cfd7436fcc-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071739.scexe"],"Name":"firmware-hdd-cfd7436fcc_0HPD4-2.1_amd64.deb","SHA1Sum":"d68129c06981dbff7702e7006aa9ab89ffb2cb3e","SHA256Sum":"431ae7bb268bbd928c2d85763ae30f336aed84a0e2b1b8574441baed2b2eab7e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWUDB Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3686c100291e41f18ff4305bed","SupportedDevices":["4d2340a5-3042-3431-3030-304a57554442"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070929.zip","SHA1Sum":"ca87fedf08ae3adb9cf3401252db8b436ade86b7","SHA256Sum":"9bd3eb9a1f9dfd0c0ea5a5d6612e7c7b9bda6674dcac3c32a5891f3b276ca5c3","SHA512Sum":"aae37fe715c4516b24ac2f6a89ec58f224a8e78501b4d1be4316a6c19099a337775cace507275a1b0cd9995a8c167344c3598851273cf3f056e289dd1b821aad"}],"ComponentSizeInKB":19300,"CompsigList":["CP070929.compsig"],"FileList":["/CP070929_BUILD_10.data","/CP070929.vmexe64","/CP070929.vmfile","/CP070929_VMw.zip","/CP070929.xml","/payload.json","/CP070929_VMw.zip/index.xml","/CP070929_VMw.zip/vendor-index.xml","/CP070929_VMw.zip/metadata.zip","/CP070929_VMw.zip/vib20/CP070929/HPE_bootbank_CP070929_HPD4.10-8.0.0.20613240.vib","/CP070929_VMw.zip/metadata.zip/vendor-index.xml","/CP070929_VMw.zip/metadata.zip/vmware.xml","/CP070929_VMw.zip/metadata.zip/vibs/CP070929--6978806674108385801.xml","/CP070929_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070929_HPD4.10-8.0.0.20613240.xml"],"Name":"CP070929.zip","SHA1Sum":"ca87fedf08ae3adb9cf3401252db8b436ade86b7","SHA256Sum":"9bd3eb9a1f9dfd0c0ea5a5d6612e7c7b9bda6674dcac3c32a5891f3b276ca5c3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070929","Version":"HPD4.10-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b1165c56296c4e42b1e596bdb6","SupportedDevices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.70 (08/19/2026)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u31-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"5af68feeecf925c264fbe8ef9a0d5e1b9543b363","SHA256Sum":"cedc52354140f8d664dc0c4e63649de147ad92da22a025779450ba553b255568","SHA512Sum":"ddffc5ff36e3ae99f6e65a68c59426c1a925dfcf18e6163151b1abd8d726c024fca15b9e738bfa32653da9f32d95e9b48fded225d7dc669c4acd0432b56ee8df"}],"ComponentSizeInKB":11266,"CompsigList":["firmware-system-u31-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.70_2026_08_19-1.1/CP073135.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.70_2026_08_19-1.1/U31_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u31-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073135.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073135.scexe"],"Name":"firmware-system-u31-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"5af68feeecf925c264fbe8ef9a0d5e1b9543b363","SHA256Sum":"cedc52354140f8d664dc0c4e63649de147ad92da22a025779450ba553b255568","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e9c4aae8f13c432fa407bc07fe","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","11.0","6.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U31","U31"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp073057.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.216"}]},"Files":[{"Checksum":[{"Filename":"cp073059.exe","SHA1Sum":"96a07b2e60541f2cb65c447bba5bb3cd51ce7376","SHA256Sum":"f071740a2b0ad6ced3341cde8a5d15535caff00e1236dffda626f88c36c79848","SHA512Sum":"e3144c8cbf4cba72f980436039870eda047d89382a8204e171f221e1e6a9b5845e66865ff529c091fd7840485ef4ea539885e239fffaa2940e392f1040084a79"}],"ComponentSizeInKB":2590,"CompsigList":["cp073059.compsig"],"FileList":["cp073057.compsig","cp073057.zip","cp073059.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp073059.exe","SHA1Sum":"96a07b2e60541f2cb65c447bba5bb3cd51ce7376","SHA256Sum":"f071740a2b0ad6ced3341cde8a5d15535caff00e1236dffda626f88c36c79848","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.216"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a2e9f49458994ccd8e09cadfac","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U44","U43"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KXG50ZNV256G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AAGA4103.sig","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AAGA4103"},{"DeviceName":"KXG50ZNV512G","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AAGA4103.sig","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AAGA4103"},{"DeviceName":"KXG50ZNV1T","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"AAGA4103.sig","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"AAGA4103"}]},"Files":[{"Checksum":[{"Filename":"cp070452.exe","SHA1Sum":"d2e02b32dc5de3caf81a26fb208aa8850adb2fef","SHA256Sum":"21b4ffe7a85a3856be6da9def8b9cc3fed914816b0905844f42433999e538745","SHA512Sum":"da2acb2f66c44845cc3208a138438940ebda53a95b315c099cfa77ca9e612b0e61f305707f3535e4f90012d566accabc19bb717f60d4bc4946626ab992fbcd32"}],"ComponentSizeInKB":7457,"CompsigList":["cp070452.compsig"],"FileList":["AAGA4103.sig","cp070452.xml","cpqsetup.exe","ilorest_chif.dll","payload.json"],"Name":"cp070452.exe","SHA1Sum":"d2e02b32dc5de3caf81a26fb208aa8850adb2fef","SHA256Sum":"21b4ffe7a85a3856be6da9def8b9cc3fed914816b0905844f42433999e538745","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"AAGA4103"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Microsoft Windows - KXG50ZNV256G, KXG50ZNV512G and KXG50ZNV1T Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"KXG50ZNV256G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KXG50ZNV512G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KXG50ZNV1T","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d92e1c665e8f4e629035cb196f","SupportedDevices":["002340a5-584b-3547-305a-4e5632353647","002340a5-584b-3547-305a-4e5635313247","002340a5-0000-584b-4735-305a4e563154"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["11.0","10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H09","H10","H10","H10","H08","H08"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069556.exe","SHA1Sum":"baf16b649044aab51fd3ea31b8a0ddfc936f26b6","SHA256Sum":"192b9b64b9ca65fc4cbe9d09ef858150a81edfa31c0886e3af3ab87789925086","SHA512Sum":"aa9ccbd4582a8a3ef8c82d0a81246ec0b5f18a6ddd0678cb1185c4da5750ca2dbd691c3de4d44877441eb98b3137391b4fcbcbfdefe2ef075f94cce7dc880567"}],"ComponentSizeInKB":834,"CompsigList":["cp069556.compsig"],"FileList":["cp069556.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs68x64.cat","vxs68x64.din","vxs68x64.inf","vxs68x64.sys","vxsmsg.dll"],"Name":"cp069556.exe","SHA1Sum":"baf16b649044aab51fd3ea31b8a0ddfc936f26b6","SHA256Sum":"192b9b64b9ca65fc4cbe9d09ef858150a81edfa31c0886e3af3ab87789925086","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf6d17a48"],"TypeOfChange":"1","Version":"2.1.252.0"}],"InstallationDependency":{},"Name":"HPE Intel vxs Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"vxs68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0e275b595b61436795ae02fc50","SupportedDevices":["a6b1a447-382a-5a4f-8086-1565159000d1","a6b1a447-382a-5a4f-8086-1565159000d2"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"CP071676.zip","SHA1Sum":"cfe8b0de1551bbb171c2040f7bbdb063155e35a1","SHA256Sum":"099d1071ba8c198326223f3e3b4df89fa4ff1a40f758b267545a5729a4fc79d2","SHA512Sum":"91dccb3a2968555028c5abd8d18aa0ee54faf32c070e87189ee28713ed1862f5ed5ee758687e72738377ff48724a3ce034676073deb11c5a05cdebbcd830c67a"}],"ComponentSizeInKB":23408,"CompsigList":["CP071676.compsig"],"FileList":["/CP071676.xml","/CP071676_VMw.zip","/payload.json","/CP071676.vmexe64","/CP071676.vmfile","/CP071676_VMw.zip/index.xml","/CP071676_VMw.zip/vendor-index.xml","/CP071676_VMw.zip/metadata.zip","/CP071676_VMw.zip/vib20/CP071676/HPE_bootbank_CP071676_1.0.2-1OEM.900.0.24755229.vib","/CP071676_VMw.zip/metadata.zip/vendor-index.xml","/CP071676_VMw.zip/metadata.zip/vmware.xml","/CP071676_VMw.zip/metadata.zip/vibs/CP071676-5176152155996728387.xml","/CP071676_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071676_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP071676.zip","SHA1Sum":"cfe8b0de1551bbb171c2040f7bbdb063155e35a1","SHA256Sum":"099d1071ba8c198326223f3e3b4df89fa4ff1a40f758b267545a5729a4fc79d2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.4","VibList":[{"Name":"CP071676","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 9.x","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_36690d551a0948008188e18f3f","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Files":[{"Checksum":[{"Filename":"cp068623.exe","SHA1Sum":"6963bfbdefad95ee3eea3300a7a644285f15aad5","SHA256Sum":"e6a1df1c99d03f92f07b0fc9bf13fba7dd3d60d351e4201342752f9439f6b9a2","SHA512Sum":"ea0cc23ffb6a2b051f7916914fbf0cc63e9e6c2a45a604051a1ed1d0b49596e25aaa2bf022cdc7c1d8b7a830f4f4a67640c0b017ae8978f193d2dd358c965281"}],"ComponentSizeInKB":3417,"CompsigList":["cp068623.compsig"],"FileList":["4ICRHPK3.rel","cp068623.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068623.exe","SHA1Sum":"6963bfbdefad95ee3eea3300a7a644285f15aad5","SHA256Sum":"e6a1df1c99d03f92f07b0fc9bf13fba7dd3d60d351e4201342752f9439f6b9a2","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c3565c0707884cfd8788bdb7d1","SupportedDevices":["4d2340a5-304f-3630-3430-304b57565641","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3330-3230-304b57565556","562340a5-304f-3230-3030-304b57565643","4d2340a5-304f-3130-3630-304b57565555"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.14"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.14"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.02"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.02"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.14"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.14"}]},"Files":[{"Checksum":[{"Filename":"firmware-fc-qlogic-2026.06.02-1.1.x86_64.rpm","SHA1Sum":"4b0acf988ed2b97c2dd9cc9fdbb1e642fae0d649","SHA256Sum":"147b65a699fb35c7857f2cd4e70d227653391ddade9c32e51be80d3c5f010377","SHA512Sum":"4cdc2aeda80431ba3fce8f6f977fd3ad249ead64def9a638684005ce7fb2a39e4108e89f14ee9e8ae352ec7833f8305f14f47f0593da3ce335892dfaa763b5ab"}],"ComponentSizeInKB":4206,"CompsigList":["firmware-fc-qlogic-2026.06.02-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/CP072109.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/adapters.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/bk020502.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/create_conf_file.sh","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/libHBAAPI.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/libHBAAPI.so.2","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/libqlcoutil.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/libqlsdm.so","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/mh021114.bin","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/qlafwupdate","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/qlafwupdate.properties","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/qlafwupdate.sub","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/qlafwupdate.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/remove_conf_file.sh","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/setup","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x103Cx1939","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x103Cx1939/BC26xx.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x103Cx1939/FWA83xxB.DAT","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00F9","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00F9/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00F9/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00F9/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00FA","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00FA/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00FA/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x00FA/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0203","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0203/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0203/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0203/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0204","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0204/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0204/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x0204/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x022D","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x022D/PEP27BC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x022D/Q27FBC.dat","./usr/lib/x86_64-linux-gnu/firmware-fc-qlogic-2026.06.02-1.1/x1590x022D/Q27FWA.dat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072109.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072109.scexe"],"Name":"firmware-fc-qlogic-2026.06.02-1.1.x86_64.rpm","SHA1Sum":"4b0acf988ed2b97c2dd9cc9fdbb1e642fae0d649","SHA256Sum":"147b65a699fb35c7857f2cd4e70d227653391ddade9c32e51be80d3c5f010377","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.06.02"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Linux (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e334d54ac552491a8f3de21454","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072212.exe","SHA1Sum":"3b589e3e33d927ecd75a2e4e7e294bbf4cf20700","SHA256Sum":"70bbfa8f11d1bb50cb55de904e7e22f193447c8898c5565b2f04f0dfbd835e1b","SHA512Sum":"ee1e9968ba030dfe4e8901ad07226f9e3d2c2b3a83291f5363ea6974fdbdb8c6e360173e633319d9022b2adb8aea16883984964344cc5530abda91423de53972"}],"ComponentSizeInKB":560,"CompsigList":["cp072212.compsig"],"FileList":["cp072212.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"Name":"cp072212.exe","SHA1Sum":"3b589e3e33d927ecd75a2e4e7e294bbf4cf20700","SHA256Sum":"70bbfa8f11d1bb50cb55de904e7e22f193447c8898c5565b2f04f0dfbd835e1b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"TypeOfChange":"0","Version":"1.0.0.0"}],"InstallationDependency":{},"Name":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2016 and Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"Switchtec.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_746ec6dfe8134081a8df73be4e","SupportedDevices":["a6b1a447-382a-5a4f-11f8-400011f84000","a6b1a447-382a-5a4f-11f8-405211f84052"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":true,"SupportedProducts":["I44","A47","A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000800JXBEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a58424556","Version":"HPD2"},{"DeviceName":"MO001600JXBFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a58424650","Version":"HPD2"},{"DeviceName":"MO003200JXBFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a58424651","Version":"HPD2"},{"DeviceName":"MO006400JXBFR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a58424652","Version":"HPD2"},{"DeviceName":"MO000960JXBFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-304a58424641","Version":"HPD2"},{"DeviceName":"MO001920JXBFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a58424654","Version":"HPD2"},{"DeviceName":"MO003840JXBFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-304a58424655","Version":"HPD2"},{"DeviceName":"MO007680JXBGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3730-3638-304a58424741","Version":"HPD2"},{"DeviceName":"MO015360JXBFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3531-3336-304a58424656","Version":"HPD2"},{"DeviceName":"EO000400JXBEU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a58424555","Version":"HPD2"},{"DeviceName":"EO000800JXBFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a5842464c","Version":"HPD2"},{"DeviceName":"EO001600JXBFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCQssssASFD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a5842464e","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-24384980ec_0HPD2-2.1_amd64.deb","SHA1Sum":"03bfc4e5dbe4020c7b4a0d3186368080a17ae95e","SHA256Sum":"4ef3e060943e7fa210310aa9ef699ec513dce83eed298f42fd4e9dcffb637b3f","SHA512Sum":"63308ca7f918f33712df42dcf0d4a8b3afa5a6da7cab3294f9dc6ec751ba1fce5c2ba5f462c9218ca733003f8eb1fe529584cf1835dea18c2bd9ae477809da10"}],"ComponentSizeInKB":3849,"CompsigList":["firmware-hdd-24384980ec_0HPD2-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/CP071747.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/WBCQssssASFD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071747.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-24384980ec-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071747.scexe"],"Name":"firmware-hdd-24384980ec_0HPD2-2.1_amd64.deb","SHA1Sum":"03bfc4e5dbe4020c7b4a0d3186368080a17ae95e","SHA256Sum":"4ef3e060943e7fa210310aa9ef699ec513dce83eed298f42fd4e9dcffb637b3f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MO000800JXBEV, MO001600JXBFP, MO003200JXBFQ, MO006400JXBFR, MO000960JXBFA, MO001920JXBFT, MO003840JXBFU, MO007680JXBGA, MO015360JXBFV, EO000400JXBEU, EO000800JXBFL and EO001600JXBFN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800JXBEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JXBFP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JXBFQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JXBFR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000960JXBFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JXBFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003840JXBFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO007680JXBGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO015360JXBFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JXBEU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JXBFL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JXBFN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_368054cc44284a828b58c9a9cc","SupportedDevices":["4d2340a5-304f-3030-3830-304a58424556","4d2340a5-304f-3130-3630-304a58424650","4d2340a5-304f-3330-3230-304a58424651","4d2340a5-304f-3630-3430-304a58424652","4d2340a5-304f-3030-3936-304a58424641","4d2340a5-304f-3130-3932-304a58424654","4d2340a5-304f-3330-3834-304a58424655","4d2340a5-304f-3730-3638-304a58424741","4d2340a5-304f-3531-3336-304a58424656","452340a5-304f-3030-3430-304a58424555","452340a5-304f-3030-3830-304a5842464c","452340a5-304f-3130-3630-304a5842464e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072279.exe","SHA1Sum":"cf77f721f2a98a44876e54a7650b1e40e8e96076","SHA256Sum":"6d37f5046e26fb26e59bab5a0e4868b73e97acd0c42da027c5c6d68eba52287c","SHA512Sum":"54862556db5f35e1966840854bce6d4f0541bf4601350fd4e426cf02e10c1d54030ca071aa05e4e276ba8489c4c93cb6205bfde233492613c351b62477b81a31"}],"ComponentSizeInKB":1708,"CompsigList":["cp072279.compsig"],"FileList":["cp072279.xml","cpqsetup.exe","cp_data.xml","icea.cat","icea.inf","icea.sys","iceamsg.dll","install.xml","manifest_icea.man","nicdrvr.dll"],"Name":"cp072279.exe","SHA1Sum":"cf77f721f2a98a44876e54a7650b1e40e8e96076","SHA256Sum":"6d37f5046e26fb26e59bab5a0e4868b73e97acd0c42da027c5c6d68eba52287c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"TypeOfChange":"1","Version":"1.21.115.0"}],"InstallationDependency":{},"Name":"Intel icea Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"icea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\icea.inf_amd64_0d313568beecbfb3"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6743b3f314e44e8da7c9fac23d","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","U47","A46","U47","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","02020001","03020101","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072193.exe","SHA1Sum":"fbfe310ba4ad4732dfe3c438a5fc66cd3cee7912","SHA256Sum":"6dfaaa60c89d3b9b3f38dc608335a3bb6cdcc12bfcbfb936f44c21c7deba51a1","SHA512Sum":"a2f02172489a879d2855cfc06c0f83315c732847c22e2c827b502ebb0d2c78f80417c91e9a65ce20d0dc52a6a39423a834a70daf1bec4b6835995ddb576d086c"}],"ComponentSizeInKB":2434,"CompsigList":["cp072193.compsig"],"FileList":["cp072193.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072193.exe","SHA1Sum":"fbfe310ba4ad4732dfe3c438a5fc66cd3cee7912","SHA256Sum":"6dfaaa60c89d3b9b3f38dc608335a3bb6cdcc12bfcbfb936f44c21c7deba51a1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"Mellanox WinOF2 Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b04f6e745236438b8fe60bd9eb","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101815b30117","a6b1a447-382a-5a4f-15b3-101e15b30040","a6b1a447-382a-5a4f-15b3-101e15b30042","a6b1a447-382a-5a4f-15b3-101615b30102","a6b1a447-382a-5a4f-15b3-101615b30047","a6b1a447-382a-5a4f-15b3-101815b30116","a6b1a447-382a-5a4f-15b3-101815b30052","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101e15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101e15b30007"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","U47","A46","U47","U48","U47","U50","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U70","U66","U71","U72","U68","A59","U72","A66","A66","U77","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-ixgbevf-5.3.36-1.rhel9u7.x86_64.rpm","SHA1Sum":"e7167d812d7e45b79cf80c0ca4e994231b61b791","SHA256Sum":"a2f54e0d5c11271bd6382d5743e0fb19711feafda89fca8841da84bb69eceeb4","SHA512Sum":"ed7fb91bfed2ccaf97a9f1b9f6fecbc37d5b1b91c4f432cfb42ee1b246b73ee4134a9da83d547e4525496c19da3812a7766e1a69236caa4d6d43eed8f92ca07f"}],"ComponentSizeInKB":87,"CompsigList":["kmod-hp-ixgbevf-5.3.36-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbevf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/63","./usr/lib/.build-id/63/43579768eb5a278445f4d87a9094944b44ff5d","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"Name":"kmod-hp-ixgbevf-5.3.36-1.rhel9u7.x86_64.rpm","SHA1Sum":"e7167d812d7e45b79cf80c0ca4e994231b61b791","SHA256Sum":"a2f54e0d5c11271bd6382d5743e0fb19711feafda89fca8841da84bb69eceeb4","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"TypeOfChange":"1","Version":"5.3.36-1"},{"Checksum":[{"Filename":"kmod-hp-ixgbevf-5.3.36-1.rhel9u8.x86_64.rpm","SHA1Sum":"7accf66f8ee80e4291c6c4a63a5a37b084bdf6a3","SHA256Sum":"9891b70f2b1d475954554beadf3321cff849653de8ed04125534eb982d2af87e","SHA512Sum":"1c121810c7f618e0806f2b386685cd825d1f86b6249f2850db1b3d21fb5408274f534b418a07b0f63b3a83e2d6cc3065c46e865c860747255af0d587b20629bd"}],"ComponentSizeInKB":86,"CompsigList":["kmod-hp-ixgbevf-5.3.36-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-ixgbevf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-ixgbevf/ixgbevf.ko","./usr/lib/.build-id","./usr/lib/.build-id/f8","./usr/lib/.build-id/f8/f8306776d9153c34a90189f0b372b7cc29ce7e","./usr/share/smartupdate/kmod-hp-ixgbevf/component.xml"],"Name":"kmod-hp-ixgbevf-5.3.36-1.rhel9u8.x86_64.rpm","SHA1Sum":"7accf66f8ee80e4291c6c4a63a5a37b084bdf6a3","SHA256Sum":"9891b70f2b1d475954554beadf3321cff849653de8ed04125534eb982d2af87e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca2355bb8"],"TypeOfChange":"1","Version":"5.3.36-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbevf","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_18b9052e60cc49108d9908996a","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d550523365_0HPD3-2.1_amd64.deb","SHA1Sum":"ea159c0d587f8c5ba971d28106ce41d0b60096d8","SHA256Sum":"a0b052783a83ea9922bdbf22b0b9b5fada9b1372f7d664f50266d1db735c2d5a","SHA512Sum":"1b00d94fd9bfc611dfad3d75475899030aa52ab3e12c16eba1d5153439fd3dd89df98497e894c1c4a0945b834a180877c83919b4b0ce5d0c9c0a110fce0427ce"}],"ComponentSizeInKB":5242,"CompsigList":["firmware-hdd-d550523365_0HPD3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/CP071793.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/PCHFA2B3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071793.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071793.scexe"],"Name":"firmware-hdd-d550523365_0HPD3-2.1_amd64.deb","SHA1Sum":"ea159c0d587f8c5ba971d28106ce41d0b60096d8","SHA256Sum":"a0b052783a83ea9922bdbf22b0b9b5fada9b1372f7d664f50266d1db735c2d5a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f6b90f2e07d2491d85b2fc54b1","SupportedDevices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U50_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U50_2.70_08_19_2026.fwpkg","SHA1Sum":"0b0a1ce240b7feebd1e42a9fca74d43aed6bf75d","SHA256Sum":"ae69444741dcba1332b1f40536a1b592c6bf7915da03c7373520a5cef30f3a97","SHA512Sum":"7317f4e39842853384e34759792eedbdae9c5d315f9d99dd02c6ed6dc504d3590938617b12e7d63a8c8914aefdc3e4c8390b038697654ef39c8ea1e58d7bb8dc"}],"ComponentSizeInKB":32814,"CompsigList":[],"FileList":["payload.json","U50_2.70_08_19_2026.signed.flash","U50_2.70_08_19_2026.xml"],"Name":"U50_2.70_08_19_2026.fwpkg","SHA1Sum":"0b0a1ce240b7feebd1e42a9fca74d43aed6bf75d","SHA256Sum":"ae69444741dcba1332b1f40536a1b592c6bf7915da03c7373520a5cef30f3a97","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ef8103d223154a2498fe544eb3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5"]}],"SupportedPlatforms":false,"SupportedProducts":["U50"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware for Intel C242 and C...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp073057.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.216"}]},"Files":[{"Checksum":[{"Filename":"firmware-dl20ml30gen10sps-05.01.05.216-1.1.x86_64.rpm","SHA1Sum":"e62de6314879b6234015e5267d32daba6b3dc363","SHA256Sum":"508cd88400f10af2ee6017a17938154a8ba32c2ca6bae4b70098edec1c0991bb","SHA512Sum":"dcb3a551a5cbf25f01d41bb7034861cad9c69cc5dfd5ae1f14866dd04cf7a292a70b8007836e7c55b574d5f48223814ee6ae33930953ecfc8d9a1abdf512d258"}],"ComponentSizeInKB":2137,"CompsigList":["firmware-dl20ml30gen10sps-05.01.05.216-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1/CP073061.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1/cp073057.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1/cp073057.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20ml30gen10sps-05.01.05.216-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073061.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073061.scexe"],"Name":"firmware-dl20ml30gen10sps-05.01.05.216-1.1.x86_64.rpm","SHA1Sum":"e62de6314879b6234015e5267d32daba6b3dc363","SHA256Sum":"508cd88400f10af2ee6017a17938154a8ba32c2ca6bae4b70098edec1c0991bb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.216"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20/ML30 Gen10","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f8bce5b2454243278ef144cc59","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U44","U43"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8e1e8083c5_0HPG3-2.1_amd64.deb","SHA1Sum":"4732aed595a567c0187491fa2de7bb7a9ce31343","SHA256Sum":"9132f1dde3341fd8f67badbe06d1d840d4f6ed25e948b5c9a78b441b91f3926a","SHA512Sum":"ae3ad94a5b262dec517b29ec2aeb048167652317d42563f008b472c5791e00201f48c05d5ba36f226340c590c0ccf7535bc8b539e36b0d6df655b08b1be3de93"}],"ComponentSizeInKB":7096,"CompsigList":["firmware-hdd-8e1e8083c5_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/CP071802.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/K503HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071802.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8e1e8083c5-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071802.scexe"],"Name":"firmware-hdd-8e1e8083c5_0HPG3-2.1_amd64.deb","SHA1Sum":"4732aed595a567c0187491fa2de7bb7a9ce31343","SHA256Sum":"9132f1dde3341fd8f67badbe06d1d840d4f6ed25e948b5c9a78b441b91f3926a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e6673dfaae74441d91bb9c137a","SupportedDevices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-netxtreme2-7.15.27-1.rhel9u7.x86_64.rpm","SHA1Sum":"22d36fa1e57a3bedfc0cebe893c52831ae707ce5","SHA256Sum":"d29ad48db00c6e41abeff5e3511b5e5dd27affbe7336877a97f0000786e8de43","SHA512Sum":"578b2df9d76acfff20ba1667be2af1c79d90363af71099855310e49b062ef8ad006359ad100ccdfc13feaed90b821b45b9f0116a3af802b6460cd04aa61b8fde"}],"ComponentSizeInKB":8710,"CompsigList":["kmod-netxtreme2-7.15.27-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/bnx2.conf","./etc/depmod.d/bnx2f.conf","./etc/depmod.d/bnx2i.conf","./etc/depmod.d/bnx2x.conf","./etc/depmod.d/cnic.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"Name":"kmod-netxtreme2-7.15.27-1.rhel9u7.x86_64.rpm","SHA1Sum":"22d36fa1e57a3bedfc0cebe893c52831ae707ce5","SHA256Sum":"d29ad48db00c6e41abeff5e3511b5e5dd27affbe7336877a97f0000786e8de43","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"TypeOfChange":"1","Version":"7.15.27-5"},{"Checksum":[{"Filename":"kmod-netxtreme2-7.15.27-5.rhel9u8.x86_64.rpm","SHA1Sum":"56537163fa487ab1bc3ba399af5beeac2fd40787","SHA256Sum":"b41ed7fae4994c0ae0fb362530b2bc1b5a5bda945ee25ec63a5a039dc2590718","SHA512Sum":"10027af94b73077a27318761e78ecb7aa1a3973e2f3c5eeeb28bbd72113b8c0df7078164c7c665f8c4fe978e096a11154752b02ef027b0e4cb8043068705487b"}],"ComponentSizeInKB":8605,"CompsigList":["kmod-netxtreme2-7.15.27-5.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/bnx2.conf","./etc/depmod.d/bnx2f.conf","./etc/depmod.d/bnx2i.conf","./etc/depmod.d/bnx2x.conf","./etc/depmod.d/cnic.conf","./etc/dracut.conf.d/netxtreme2.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/netxtreme2","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/netxtreme2/bnx2.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/netxtreme2/bnx2fc.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/netxtreme2/bnx2i.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/netxtreme2/bnx2x.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/netxtreme2/cnic.ko","./usr/share/smartupdate/kmod-netxtreme2/component.xml"],"Name":"kmod-netxtreme2-7.15.27-5.rhel9u8.x86_64.rpm","SHA1Sum":"56537163fa487ab1bc3ba399af5beeac2fd40787","SHA256Sum":"b41ed7fae4994c0ae0fb362530b2bc1b5a5bda945ee25ec63a5a039dc2590718","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e"],"TypeOfChange":"1","Version":"7.15.27-5"}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-netxtreme2","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4456b17650ce491da0c76174db","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16af103c1933","a6b1a447-382a-5a4f-14e4-16ad103c1917","a6b1a447-382a-5a4f-14e4-16ae103c3382","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Video","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069739.exe","SHA1Sum":"c0d8e70cc76941d60df8314bdd9f164b6527c259","SHA256Sum":"044990fed406c368ad87b742fa1f26ef4647b1909c97c366922f6f3815d1e95b","SHA512Sum":"f1e1b6ba743822d78a00dcb0774be20dc5644674a7e194910bd20cc3669da66cca8ccc945e5455c2ec0e62bbcffc3f7213f611a30eb68e12beee2a87bb42fda4"}],"ComponentSizeInKB":1600,"CompsigList":["cp069739.compsig"],"FileList":["cp069739.xml","cpqsetup.exe","generic.dll","install.xml","Matrox.WddmUninstaller.exe","mxg200eh.cat","MxG200eH.inf","MxG2hDO64.sys"],"Name":"cp069739.exe","SHA1Sum":"c0d8e70cc76941d60df8314bdd9f164b6527c259","SHA256Sum":"044990fed406c368ad87b742fa1f26ef4647b1909c97c366922f6f3815d1e95b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc83136f6"],"TypeOfChange":"0","Version":"9.15.1.268"}],"InstallationDependency":{},"Name":"Matrox G200eH3 Video Controller Driver for Microsoft Windows 64-bit","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"MxG2hDO64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3c4ee434232a45659b386e450c","SupportedDevices":["a6b1a447-382a-5a4f-102b-0538159000e4","a6b1a447-382a-5a4f-102b-05381590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399","10.0.20317.25398","10.0.17600.18999","10.0","10.0"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","U61","U60","U56","A42","A43","A42","A43","H10","H08","H08","H10","H10","A48","U50","U39","U40","I41","U36","U43","U45","U37","U38","U38","U64","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57412 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957412N4120HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41594","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957412N4120HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41594","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957412N4120HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41594","Version":"238.1.169.0"}]},"Files":[{"Checksum":[{"Filename":"BCM238.1.169.0_BCM957412N4120HC.fwpkg","SHA1Sum":"5ede87bf73e63b8f120bdc4df78f5109890c8d04","SHA256Sum":"b8732203dbe8597161d53fe046df9212dfad69f899d26de523b207a89761faa3","SHA512Sum":"c003eb50f036002531584c9ec358b3324d840c1107218afc0ed2bd0a5eb83168020482204fecf9b9aa1a968c61c547922fbbfafafd715336861a619370297bd6"}],"ComponentSizeInKB":1430,"CompsigList":[],"FileList":["BCM238.1.169.0_BCM957412N4120HC.HPb","BCM238.1.169.0_BCM957412N4120HC.xml","payload.json"],"Name":"BCM238.1.169.0_BCM957412N4120HC.fwpkg","SHA1Sum":"5ede87bf73e63b8f120bdc4df78f5109890c8d04","SHA256Sum":"b8732203dbe8597161d53fe046df9212dfad69f899d26de523b207a89761faa3","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594"],"TypeOfChange":"1","Version":"238.1.169.0"}],"InstallationDependency":{},"Name":"Broadcom Firmware Package for BCM57412 OCP3 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE_57412OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_80dcff8b31174dceafcb6e57e1","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16de14e41594"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"cp072379.exe","SHA1Sum":"cb40bcc93f55bfe5c33f436034d96954b099aafa","SHA256Sum":"fc28cc53faf8eed74c569c9cbb0858fec3bc8d8c40bcd1670596e1301d19de48","SHA512Sum":"ebd58f3de492e42c618def45f02b0e08242b31f5808a6d9c3250f2a811e2b7ff33bd341e02b501318249f50373c5a27af95d46988e9ac6666fce6628fdbc71de"}],"ComponentSizeInKB":22084,"CompsigList":["cp072379.compsig"],"FileList":["cp072379.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072379.exe","SHA1Sum":"cb40bcc93f55bfe5c33f436034d96954b099aafa","SHA256Sum":"fc28cc53faf8eed74c569c9cbb0858fec3bc8d8c40bcd1670596e1301d19de48","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.0.10"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_800b0edf4bbe46f888be289c6a","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.2","6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U32","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U39","U56","U61","U37"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u1.x86_64.rpm","SHA1Sum":"43bfd10066e2d0c4abc3e47acfd854d2438a72f4","SHA256Sum":"4f4001783373cca16d13f202b1e8bc268b176eabbaec985f9d04269783ef3c6c","SHA512Sum":"db75e1b9becee6c9882f19d5eff25081069244b50d21aa294f5084df7570838de164dd7988581718ce4a86c77fec855226fb8d23976c73cb915a207d7245da3c"}],"ComponentSizeInKB":5436,"CompsigList":["kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-qla2xxx","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"Name":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u1.x86_64.rpm","SHA1Sum":"43bfd10066e2d0c4abc3e47acfd854d2438a72f4","SHA256Sum":"4f4001783373cca16d13f202b1e8bc268b176eabbaec985f9d04269783ef3c6c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 10 Update 1 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_44e21d14ab074e93920087a448","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 MCX562A-ACAI OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"16_35_8008-MCX562A-ACA_Ax_Bx.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101715b30052","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"16_35_8008-MCX562A-ACA_Ax_Bx.pldm.fwpkg","SHA1Sum":"c9e0d1561ef4ab3344cbe9b925fbd3a98d41c57a","SHA256Sum":"e91eedca6d8c59c36bd7b0346e60d58cd4007389cd3dddd4df6a22f5162375b6","SHA512Sum":"b72983a6c9014cf3e34b5c4ea6bd0a9204c1fe589a6e0886da64452c33a279bb2e6d35ccf5f8a429e28e7f1c7ffaddd90b9df212e98fb062531383c3df5eaa86"}],"ComponentSizeInKB":5513,"CompsigList":[],"FileList":["16_35_8008-MCX562A-ACA_Ax_Bx.pldm.signed","16_35_8008-MCX562A-ACA_Ax_Bx.pldm.xml","payload.json"],"Name":"16_35_8008-MCX562A-ACA_Ax_Bx.pldm.fwpkg","SHA1Sum":"c9e0d1561ef4ab3344cbe9b925fbd3a98d41c57a","SHA256Sum":"e91eedca6d8c59c36bd7b0346e60d58cd4007389cd3dddd4df6a22f5162375b6","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715b30052"],"TypeOfChange":"1","Version":"16.35.8008"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX562A-ACAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX562A-ACAI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6b991dd9868344ce9f5a5a03dc","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30052"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0","10.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","A48","U48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U54","U54"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Files":[{"Checksum":[{"Filename":"CP070917.zip","SHA1Sum":"425044d472e0b453cc19bd21350a293b2ca10ec9","SHA256Sum":"ee1fa0c53a8224247e37f8c5802fbe9c89345305181e015ab24eea1e65862e36","SHA512Sum":"392000d924b9e8e66fa53d075bc16dbd404a118b897d6e48b04892411a5b6ad0f1a8423efed8e98d3308386a20e1ca2fb6b61b0868b0c9bfa485c604b5e11b3c"}],"ComponentSizeInKB":26905,"CompsigList":["CP070917.compsig"],"FileList":["/CP070917_BUILD_3.data","/CP070917.vmexe64","/CP070917.vmfile","/CP070917_VMw.zip","/CP070917.xml","/payload.json","/CP070917_VMw.zip/index.xml","/CP070917_VMw.zip/vendor-index.xml","/CP070917_VMw.zip/metadata.zip","/CP070917_VMw.zip/vib20/CP070917/HPE_bootbank_CP070917_MPK7825Q.3-8.0.0.20613240.vib","/CP070917_VMw.zip/metadata.zip/vendor-index.xml","/CP070917_VMw.zip/metadata.zip/vmware.xml","/CP070917_VMw.zip/metadata.zip/vibs/CP070917-7693931915171505373.xml","/CP070917_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070917_MPK7825Q.3-8.0.0.20613240.xml"],"Name":"CP070917.zip","SHA1Sum":"425044d472e0b453cc19bd21350a293b2ca10ec9","SHA256Sum":"ee1fa0c53a8224247e37f8c5802fbe9c89345305181e015ab24eea1e65862e36","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q","VibList":[{"Name":"CP070917","Version":"MPK7825Q.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bf93a6c84c08409e91b268b1c8","SupportedDevices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.14"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.14"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.02"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.02"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.14"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.14"}]},"Files":[{"Checksum":[{"Filename":"CP072107.zip","SHA1Sum":"bca2e34f0617b02a0003221c55699ead44cdacae","SHA256Sum":"597eeb634d6111715fb7efe206a268095e55c29247fe8db34c0828b5aaeefaf8","SHA512Sum":"f8ca2088862163510ac3124cc17a72575dc1bb1f77525614efd7a753471a8935227dfcd4e3adfdd405d2729ba46288e597d9b618f4ee30cbb2be8b255ec50328"}],"ComponentSizeInKB":7764,"CompsigList":["CP072107.compsig"],"FileList":["/CP072107_BUILD_1.data","/CP072107.vmexe","/CP072107.vmexe64","/CP072107.vmfile","/CP072107_VMw.zip","/CP072107.xml","/payload.json","/CP072107_VMw.zip/index.xml","/CP072107_VMw.zip/vendor-index.xml","/CP072107_VMw.zip/metadata.zip","/CP072107_VMw.zip/vib20/CP072107/HPE_bootbank_CP072107_2026.06.02.1-8.0.0.20613240.vib","/CP072107_VMw.zip/metadata.zip/vendor-index.xml","/CP072107_VMw.zip/metadata.zip/vmware.xml","/CP072107_VMw.zip/metadata.zip/vibs/CP072107-4808322845179425364.xml","/CP072107_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072107_2026.06.02.1-8.0.0.20613240.xml"],"Name":"CP072107.zip","SHA1Sum":"bca2e34f0617b02a0003221c55699ead44cdacae","SHA256Sum":"597eeb634d6111715fb7efe206a268095e55c29247fe8db34c0828b5aaeefaf8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.06.02","VibList":[{"Name":"CP072107","Version":"2026.06.02.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2c98712c88e44f4eb25afe0940","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-f36d4ef431_0.39-2.1_amd64.deb","SHA1Sum":"afc5fbd46fc73decc95db8e0bbfa2289655dcb76","SHA256Sum":"7aba29e686eb580a785ff3207ce2b9118b582eec106a6fb3d1dfa23fe1f634d4","SHA512Sum":"739ba0fc9840e7011faa50c511e02afa227aac310c7a63db8aea2e79e7d6874389ac473fa42ad2f10bdde476aef91efab4a15ee792569feac70a720ecfb74e1e"}],"ComponentSizeInKB":3265,"CompsigList":["firmware-smartarray-f36d4ef431_0.39-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/CP071701.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/Eaglescanyon-Release-0.39.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071701.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071701.scexe"],"Name":"firmware-smartarray-f36d4ef431_0.39-2.1_amd64.deb","SHA1Sum":"afc5fbd46fc73decc95db8e0bbfa2289655dcb76","SHA256Sum":"7aba29e686eb580a785ff3207ce2b9118b582eec106a6fb3d1dfa23fe1f634d4","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Ubuntu – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_66f0df2fb5c049d894d56c7cfb","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":true,"SupportedProducts":["U50","U50"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.21"}]},"Files":[{"Checksum":[{"Filename":"CP071318.zip","SHA1Sum":"ac3a4b10b8b5f2480c72108bc04e8ffa0d69a95a","SHA256Sum":"98d7ec40e3dbb929dcdf3ab002a4a67d27453c1fb16ac8f65cd0fccad8c97479","SHA512Sum":"40f020683658836254215922d65b2ce5250130630619dad6cc8533e84a6f90cc2be87c4b6a2ca4bdde1ad58206701e54222eff72633f705e25556f49b101fde1"}],"ComponentSizeInKB":4727,"CompsigList":["CP071318.compsig"],"FileList":["/CP071318_BUILD_4.data","/CP071318.vmexe","/CP071318.vmexe64","/CP071318.vmfile","/CP071318_VMw.zip","/CP071318.xml","/payload.json","/CP071318_VMw.zip/index.xml","/CP071318_VMw.zip/vendor-index.xml","/CP071318_VMw.zip/metadata.zip","/CP071318_VMw.zip/vib20/CP071318/HPE_bootbank_CP071318_CP071318.4-1OEM.900.0.24755229.vib","/CP071318_VMw.zip/metadata.zip/vendor-index.xml","/CP071318_VMw.zip/metadata.zip/vmware.xml","/CP071318_VMw.zip/metadata.zip/vibs/CP071318--6414400687397042827.xml","/CP071318_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071318_CP071318.4-1OEM.900.0.24755229.xml"],"Name":"CP071318.zip","SHA1Sum":"ac3a4b10b8b5f2480c72108bc04e8ffa0d69a95a","SHA256Sum":"98d7ec40e3dbb929dcdf3ab002a4a67d27453c1fb16ac8f65cd0fccad8c97479","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01","VibList":[{"Name":"CP071318","Version":"CP071318.4-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f18aaf340f6d4f549dfdc8b844","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-238.1.165.0-rhel10u2.x86_64.rpm","SHA1Sum":"b813e3c48e023fc7fb2106fbc7796310d634ded2","SHA256Sum":"c47feb3867a9c0bf29cf1550a0172cac091498546c515b0f163b218d862cbdbe","SHA512Sum":"e11e0893472fe300711eb84f7e18a967fb2c1def9263ee36561ab13caa62e4a98949b97a28301bd60ba61aa705f22e8e017ac9a394d9edaea3497c7a25522478"}],"ComponentSizeInKB":65,"CompsigList":["libbnxt_re-238.1.165.0-rhel10u2.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/d0","./usr/lib/.build-id/d0/6474161cf0657cf6cc7f05809ec69dc882f954","./usr/lib64/libbnxt_re-238.1.165.0.so","./usr/lib64/libbnxt_re-rdmav59.so","./usr/lib64/libbnxt_re.so","./usr/lib64/pkgconfig/libbnxt_re.pc","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-238.1.165.0-rhel10u2.x86_64.rpm","SHA1Sum":"b813e3c48e023fc7fb2106fbc7796310d634ded2","SHA256Sum":"c47feb3867a9c0bf29cf1550a0172cac091498546c515b0f163b218d862cbdbe","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 2.","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ea7d44c9adb64ae6adac48aecb","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-ixgbevf-5.3.36-1.rhel10u1.x86_64.rpm","SHA1Sum":"3dc3e2b06e40a01db5699632d8ebe170715adcbe","SHA256Sum":"6680af534f015672b5ce4a55a0294652793fab63a402d857695dfe3f3d9ffb16","SHA512Sum":"243b9c83366b240bcca5fbd36d71278506633c26657d7a16f926dfcacf0b54afbbc08412040040c0eaad7bef2a2cc13e45e0ba9a5d2416fe7613f777f7c15f57"}],"ComponentSizeInKB":113,"CompsigList":["kmod-ixgbevf-5.3.36-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ixgbevf.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/ixgbevf/ixgbevf.ko","./usr/share/doc/kmod-ixgbevf","./usr/share/doc/kmod-ixgbevf/COPYING","./usr/share/doc/kmod-ixgbevf/README","./usr/share/doc/kmod-ixgbevf/pci.updates","./usr/share/man/man7/ixgbevf.7.gz","./usr/share/smartupdate/kmod-ixgbevf/component.xml"],"Name":"kmod-ixgbevf-5.3.36-1.rhel10u1.x86_64.rpm","SHA1Sum":"3dc3e2b06e40a01db5699632d8ebe170715adcbe","SHA256Sum":"6680af534f015672b5ce4a55a0294652793fab63a402d857695dfe3f3d9ffb16","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2eb7029e"],"TypeOfChange":"1","Version":"5.3.36-1"},{"Checksum":[{"Filename":"kmod-ixgbevf-5.3.36-1.rhel10u2.x86_64.rpm","SHA1Sum":"084d2125eb7bbeb3d4599aed5b308af5184c3bc0","SHA256Sum":"db11bc82f020db3afbb23744b656c46e76c3052cbcaf068dc01599639558af20","SHA512Sum":"4177271b9a71d8080edce287f6dee9403b5d59cdccc3030d0a06d36353f2f725947bbaef6a8e0f7c6a93c699fdfa949ab8e1245f3001ff52841b4b84bee006b5"}],"ComponentSizeInKB":112,"CompsigList":["kmod-ixgbevf-5.3.36-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ixgbevf.conf","./lib/modules/6.12.0-211.7.1.el10_2.x86_64/extra/ixgbevf/ixgbevf.ko","./usr/share/doc/kmod-ixgbevf","./usr/share/doc/kmod-ixgbevf/COPYING","./usr/share/doc/kmod-ixgbevf/README","./usr/share/doc/kmod-ixgbevf/pci.updates","./usr/share/man/man7/ixgbevf.7.gz","./usr/share/smartupdate/kmod-ixgbevf/component.xml"],"Name":"kmod-ixgbevf-5.3.36-1.rhel10u2.x86_64.rpm","SHA1Sum":"084d2125eb7bbeb3d4599aed5b308af5184c3bc0","SHA256Sum":"db11bc82f020db3afbb23744b656c46e76c3052cbcaf068dc01599639558af20","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2eb7029e"],"TypeOfChange":"1","Version":"5.3.36-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbevf Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ixgbevf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ixgbevf","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_89fd436745be41c68dc2c6f91e","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U68","U68","U68","U71","U69","A58","U69","U71","U72","U68","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"CP072400.zip","SHA1Sum":"65c67e6c47774941d42dfc5f07a9beb6ad9f45d2","SHA256Sum":"1e77f17d1245eb1f586b8f2395e6c455474265dc5fbc5ab8f803f3f9bd7ac15d","SHA512Sum":"3a4c9f5acf9fc4545640ee159b87293fa44f988f59aeb039fe4cf94b8fa12fa82349c5f01e92219e784600c160bd33d1264f59dcbff2be420c1d03038100c197"}],"ComponentSizeInKB":24976,"CompsigList":["CP072400.compsig"],"FileList":["/CP072400.xml","/CP072400_VMw.zip","/payload.json","/CP072400.vmexe64","/CP072400.vmfile","/CP072400_VMw.zip/index.xml","/CP072400_VMw.zip/vendor-index.xml","/CP072400_VMw.zip/metadata.zip","/CP072400_VMw.zip/vib20/CP072400/HPE_bootbank_CP072400_1.0.2-1OEM.900.0.24755229.vib","/CP072400_VMw.zip/metadata.zip/vendor-index.xml","/CP072400_VMw.zip/metadata.zip/vmware.xml","/CP072400_VMw.zip/metadata.zip/vibs/CP072400--3093516677357361105.xml","/CP072400_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072400_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP072400.zip","SHA1Sum":"65c67e6c47774941d42dfc5f07a9beb6ad9f45d2","SHA256Sum":"1e77f17d1245eb1f586b8f2395e6c455474265dc5fbc5ab8f803f3f9bd7ac15d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP072400","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 9.x","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e2484286db1447d6a8c5001d4e","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","U31","U31","U41","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-54addf5312_0HPK4-2.1_amd64.deb","SHA1Sum":"1e0357f5050fa633037224bfd16e540261acb717","SHA256Sum":"ea937c0a9565763661d8ac078577bf7d8f8d0cd21403ac98c80e275366ceda63","SHA512Sum":"55385d64f8eee1e0a0c318d85afdab3a6d191add198271f47ff6a4021ca630a94a6e92e7bd35dc683fff2e94a5097792a037978d64c2596071a35d71992e4cc5"}],"ComponentSizeInKB":3885,"CompsigList":["firmware-hdd-54addf5312_0HPK4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/CP071741.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/KPE60X1GHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071741.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071741.scexe"],"Name":"firmware-hdd-54addf5312_0HPK4-2.1_amd64.deb","SHA1Sum":"1e0357f5050fa633037224bfd16e540261acb717","SHA256Sum":"ea937c0a9565763661d8ac078577bf7d8f8d0cd21403ac98c80e275366ceda63","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2c493c29c3814b949a0d96a017","SupportedDevices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ef93133161_0HPD4-2.1_amd64.deb","SHA1Sum":"86ad753d327a978060428b246d426e0094a61b00","SHA256Sum":"ed183371daa2069723886222b54416c76864b41b0b5ea1512f790334e0df86f7","SHA512Sum":"86b088b9d0c525e554bb5f0098a1290ae169bc11490bf3856d9a925481c6ba1da1b18a62e754bdb72352b58e23010163e121093882573a6a70f5896990275bb9"}],"ComponentSizeInKB":3822,"CompsigList":["firmware-hdd-ef93133161_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/CP071746.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/WBCPssssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071746.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071746.scexe"],"Name":"firmware-hdd-ef93133161_0HPD4-2.1_amd64.deb","SHA1Sum":"86ad753d327a978060428b246d426e0094a61b00","SHA256Sum":"ed183371daa2069723886222b54416c76864b41b0b5ea1512f790334e0df86f7","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2606a03735e547cea7846aba23","SupportedDevices":["4d2340a5-304f-3630-3430-304a57554742","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3130-3630-304a57554656","452340a5-304f-3130-3630-304a57554745","4d2340a5-304f-3030-3830-304a57554655","452340a5-304f-3030-3830-304a57554744","4d2340a5-304f-3030-3430-304a57554654","452340a5-304f-3030-3430-304a57554743"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A40_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072013.exe","SHA1Sum":"17f8abfb16e397bcac00a7104f02b47b736cf4f5","SHA256Sum":"9a8afa73edcc31b7bc3310763ef37b0d80b2aafe3d4de0ccb34df4d19a238611","SHA512Sum":"6cb6880110eed26ebf4f33b02755afd04990bf7ce91b941132458614844f2f6659c35af3db98cbe71c7ed2fdcb458b83f1d7b6ff93bedeb3cef6edc6fa750673"}],"ComponentSizeInKB":17771,"CompsigList":["cp072013.compsig"],"FileList":["A40_3.80_05_28_2026.signed.flash","cp072013.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp072013.exe","SHA1Sum":"17f8abfb16e397bcac00a7104f02b47b736cf4f5","SHA256Sum":"9a8afa73edcc31b7bc3310763ef37b0d80b2aafe3d4de0ccb34df4d19a238611","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL385 Gen10 (A40) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8c2e8eb1d48849eb994fd1d003","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.25399","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A40"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072278.exe","SHA1Sum":"49c86e2c3a48172f0e6c8b5ec8e88ac858b0ff13","SHA256Sum":"8d36379370c8f11bfe04750efd44220a1e181da42182c51501eeaf0462098f77","SHA512Sum":"728f1a5a8c44563464d09cb19285b3929488a40c05841c927e6e11bf5c76498b34c60c0b4d32d2e87d256c454b2dbe5cd462e40cd1ff07d55d60f7f332f94c51"}],"ComponentSizeInKB":1708,"CompsigList":["cp072278.compsig"],"FileList":["cp072278.xml","cpqsetup.exe","cp_data.xml","icea68.cat","icea68.din","icea68.inf","icea68.sys","iceamsg.dll","install.xml","manifest_icea68.man","nicdrvr.dll"],"Name":"cp072278.exe","SHA1Sum":"49c86e2c3a48172f0e6c8b5ec8e88ac858b0ff13","SHA256Sum":"8d36379370c8f11bfe04750efd44220a1e181da42182c51501eeaf0462098f77","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b103d04"],"TypeOfChange":"1","Version":"1.21.113.0"}],"InstallationDependency":{},"Name":"Intel icea Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"icea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_080b7769ef3c4b47aa9ed95d1a","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","U47","A46","U47","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","02020001","03020101","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-igb-5.20.28-1.rhel9u8.x86_64.rpm","SHA1Sum":"8c6814534e5015d76dcf1f8b537d3b61cc1cc72d","SHA256Sum":"493a93df1601198c68c26f79c554ede332a8c8146c34873bb182957f345e2d77","SHA512Sum":"bad1b3fe00b7d87ba6867f4eb9a9699f4ef15ba87266b399333d9b1814376a4db472d3fe6e251b9d57f60917a38a3e696cb93b327876770c45a4377ec559ea7e"}],"ComponentSizeInKB":181,"CompsigList":["kmod-hp-igb-5.20.28-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-igb","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/c6","./usr/lib/.build-id/c6/2195ac5275c2bb18bb50f1799ae957f539677a","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"Name":"kmod-hp-igb-5.20.28-1.rhel9u8.x86_64.rpm","SHA1Sum":"8c6814534e5015d76dcf1f8b537d3b61cc1cc72d","SHA256Sum":"493a93df1601198c68c26f79c554ede332a8c8146c34873bb182957f345e2d77","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"TypeOfChange":"1","Version":"5.20.28-1"},{"Checksum":[{"Filename":"kmod-hp-igb-5.20.28-1.rhel9u7.x86_64.rpm","SHA1Sum":"8ec0b9e0ec4119d9e2fb4cd24eb6ee52dbe83512","SHA256Sum":"86ea9669760494b9d547e7473fbae240d17b90be56aee46ab3a0c3e3d4c398a2","SHA512Sum":"f0fdc122a59cf35f3c074dcd2ba959fc399d9fb1fd7c2fe5292fdf17466b25a3f50c6cc7cbb2c20cef4a3da64838b3e32c8fdeb96194831e089fc2a41fde107d"}],"ComponentSizeInKB":184,"CompsigList":["kmod-hp-igb-5.20.28-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-igb","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-igb/igb.ko","./usr/lib/.build-id","./usr/lib/.build-id/66","./usr/lib/.build-id/66/811b0099198aef7382e0417d4fa262622ec681","./usr/share/smartupdate/kmod-hp-igb/component.xml"],"Name":"kmod-hp-igb-5.20.28-1.rhel9u7.x86_64.rpm","SHA1Sum":"8ec0b9e0ec4119d9e2fb4cd24eb6ee52dbe83512","SHA256Sum":"86ea9669760494b9d547e7473fbae240d17b90be56aee46ab3a0c3e3d4c398a2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211"],"TypeOfChange":"1","Version":"5.20.28-1"}],"InstallationDependency":{},"Name":"HPE Intel igb Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-igb","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_70dc2184a29548c5bbb266ffb3","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H10","H10","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U61_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.70 (08/20/2026)"}]},"Files":[{"Checksum":[{"Filename":"U61_2.70_08_20_2026.fwpkg","SHA1Sum":"a4f742f5d4c67641d7b1ed260090dcc557d9536e","SHA256Sum":"b7af4e1b0318a2828fcc064953fa67056bed9d6c2b843153dd58dffd0d5dbaf1","SHA512Sum":"0a3ba37c85689f4fa3afdbdbac2cc221f40d8ce647071bfc0e19469284b56327155a054bcfa37372335859d32ce3b57923cff286c90beb5ac1b2420fab908441"}],"ComponentSizeInKB":16423,"CompsigList":[],"FileList":["payload.json","U61_2.70_08_20_2026.signed.flash","U61_2.70_08_20_2026.xml"],"Name":"U61_2.70_08_20_2026.fwpkg","SHA1Sum":"a4f742f5d4c67641d7b1ed260090dcc557d9536e","SHA256Sum":"b7af4e1b0318a2828fcc064953fa67056bed9d6c2b843153dd58dffd0d5dbaf1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.70_08-20-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant ML30 Gen10 Plus Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_faf15b74778648818e8d156ec2","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE NV60100M 100Gb 2p Strg Offload Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"22_45_1020-R8M41-63001_Ax_header.pldm.signed.flash","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101d1590037d","Version":"22.45.1020"}]},"Files":[{"Checksum":[{"Filename":"22_45_1020-R8M41-63001_Ax_header.pldm.fwpkg","SHA1Sum":"1a32f3726fcd0000115b17bbc62931684c1cda75","SHA256Sum":"428990927bca7fd1fdd09963709a552fdc38debc0f45b7208cf64dc72f937c67","SHA512Sum":"3ec2dd907ce7a48ff70649f04f7ffb97df0931da4d8299c2cf90096fac201ad147dbf05d7aecd2999f74716268457135e2ee5935243348d20769a92ea925f5e5"}],"ComponentSizeInKB":7548,"CompsigList":[],"FileList":["22_45_1020-R8M41-63001_Ax_header.pldm.signed.flash","22_45_1020-R8M41-63001_Ax_header.pldm.xml","payload.json"],"Name":"22_45_1020-R8M41-63001_Ax_header.pldm.fwpkg","SHA1Sum":"1a32f3726fcd0000115b17bbc62931684c1cda75","SHA256Sum":"428990927bca7fd1fdd09963709a552fdc38debc0f45b7208cf64dc72f937c67","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d1590037d"],"TypeOfChange":"1","Version":"22.45.1020"}],"InstallationDependency":{},"Name":"Mellanox Firmware Package(FWPKG) for HPE NVIDIA Ethernet 100Gb 2-port NVMe-oF Offload Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7319fd82a07c4804b3f42bdb8e","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101d1590037d"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","12.0","15.0","10.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","A42","U46","A43","U50","HPE Apollo 2000 Gen10 Plus System","U54","U54","U58","U58","U63","U57","A55","A55","A56","A56","U59","U58","U68","U68","U68","U71","HPE ProLiant DL380m Gen12","U71","U72","U77","U72"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U44","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U44_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021a","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u44-3.76_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"42b7708c02d146063adf73ade95d4e78d9385d7c","SHA256Sum":"36f93ce5bc9af43fd08b63adf95e7583c179aebaedcc23f2afcd712ed7a726a7","SHA512Sum":"ab4ac200f4facc2dd05e38fad487e2e9fd48bac5961879915e2cb38e61facf65d2a47c3a5c04df52fdeb96b543f4d8bcf8d21990f893510039ce9466b548a097"}],"ComponentSizeInKB":8742,"CompsigList":["firmware-system-u44-3.76_2026_05_28-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/CP072039.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/U44_3.76_05_28_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u44-3.76_2026_05_28-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072039.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072039.scexe"],"Name":"firmware-system-u44-3.76_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"42b7708c02d146063adf73ade95d4e78d9385d7c","SHA256Sum":"36f93ce5bc9af43fd08b63adf95e7583c179aebaedcc23f2afcd712ed7a726a7","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021a"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant ML30 Gen10 (U44) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U44","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fc949a58e3044ed6b20aa4c9b0","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","15.0","12.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U44"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL8WBA0HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-82894b9e0a_0HPG4-2.1_amd64.deb","SHA1Sum":"719396c249c78c07568b80bf0d859a844624e528","SHA256Sum":"6175576257f63abe51a409820ea41eea7d964a943df38ff7e7c0b97c397caf1c","SHA512Sum":"865879098a1985eaea842ad16ad341da36e2f8272fe3b97da1f305d67af29a8e5e3a97c73914d979aa7641239776ef8a15ec5f84b360028d6011462dee7c7273"}],"ComponentSizeInKB":4583,"CompsigList":["firmware-hdd-82894b9e0a_0HPG4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/CP073300.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/WVL8WBA0HPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073300.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073300.scexe"],"Name":"firmware-hdd-82894b9e0a_0HPG4-2.1_amd64.deb","SHA1Sum":"719396c249c78c07568b80bf0d859a844624e528","SHA256Sum":"6175576257f63abe51a409820ea41eea7d964a943df38ff7e7c0b97c397caf1c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000GWRTC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d020b9b7736c4d7983a3e1cd53","SupportedDevices":["4d2340a5-3042-3830-3030-304757525443"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-6fc985bd3b_0GPK8-2.1_amd64.deb","SHA1Sum":"ba1b3f32ac274db5cb443488ed0e3c8d7d7446bf","SHA256Sum":"c54c9f631ec1939414f8fdf3f04628b71c2826dfb35407723bd045f689bdf843","SHA512Sum":"7da6d8cc99b0ed49e273826a90e9ff830de82ab8bf1c9e914d9169755a9cc19d04d458135206897e4df129f15157206f05f7d6cb90b731b8785cec867c154ae0"}],"ComponentSizeInKB":4771,"CompsigList":["firmware-hdd-6fc985bd3b_0GPK8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/CP071772.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/KACD6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071772.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071772.scexe"],"Name":"firmware-hdd-6fc985bd3b_0GPK8-2.1_amd64.deb","SHA1Sum":"ba1b3f32ac274db5cb443488ed0e3c8d7d7446bf","SHA256Sum":"c54c9f631ec1939414f8fdf3f04628b71c2826dfb35407723bd045f689bdf843","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_327f159d1a0f46f9a28161a357","SupportedDevices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd_5.1.0-2197.8-ubuntu26_amd64.deb","SHA1Sum":"4f845ac7207917477cd196741777286534ec5e76","SHA256Sum":"b7ee90d1af7db1a2eb9f3265af3f66a57e11143ca22fd89323646619b95e4575","SHA512Sum":"bfb9e9b5bbfcf819f69682d9535a7664df6868da84dd4b8d6c7b24cd0275992ce0a8f4b86ff29448c984ecc5af3e14a1a04164244851173ca269730a8acd7614"}],"ComponentSizeInKB":8952,"CompsigList":["amsd_5.1.0-2197.8-ubuntu26_amd64.compsig"],"FileList":["./etc/default/ahslog","./etc/default/amsd","./etc/default/amsd_rev","./etc/default/cpqIde","./etc/default/cpqScsi","./etc/default/cpqiScsi","./etc/default/mr_cpqScsi","./etc/default/smad","./etc/default/smad_rev","./lib/udev/rules.d/81-cpqFca.rules","./lib/udev/rules.d/81-cpqiScsi.rules","./sbin/ahslog","./sbin/amscli","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqIde","./sbin/cpqScsi","./sbin/cpqiScsi","./sbin/mr_cpqScsi","./sbin/smad","./sbin/smad_rev","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/share/amsd/amsd.license","./usr/share/doc/amsd/README.Debian","./usr/share/doc/amsd/changelog.Debian.gz","./usr/share/doc/amsd/copyright","./usr/share/man/man1/ahslog.1m.gz","./usr/share/man/man1/smad.1m.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/smartupdate/amsd/component.xml"],"Name":"amsd_5.1.0-2197.8-ubuntu26_amd64.deb","SHA1Sum":"4f845ac7207917477cd196741777286534ec5e76","SHA256Sum":"b7ee90d1af7db1a2eb9f3265af3f66a57e11143ca22fd89323646619b95e4575","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"5.1.0"}],"InstallationDependency":{},"Name":"Agentless Management Service for Ubuntu 26.04 LTS","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_26c168ee6d3341d1a2a1605c63","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","A40","U30","U32","I42","U38","U38","U34","I43","A42","A43","A41","A42","A43","A42","A43","U46","U46","A55","A56","A55","A56","U54","U54","U54","U63","U63","U59","U58","U58","I45","I44","U69","U69","U68","U68","U68","U62","U77","U71","U83","A72"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-SummitAS-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_SummitAS_SUMMITSUASG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"002340a5-424d-3432-3030-30475945564b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"Seagate_SummitAS_SUMMITSUASG3.fwpkg","SHA1Sum":"9e50a13bb4f3588e642c951b1fc94ac2574bb28f","SHA256Sum":"736327814937e6586bb8ca1efc10a0f4976fb53cd1d869e3c1217cbbecd0ba12","SHA512Sum":"4b0672a4a5ab6bc011189ed2ea91affe98613b62bec1b8bed1c1f5f451bc51cfc504a79a0831217ea3a918da2fe5e6b8b7a9265e05addec7c12272b95d92bb24"}],"ComponentSizeInKB":3679,"CompsigList":[],"FileList":["payload.json","Seagate_SummitAS_SUMMITSUASG3.HPb","Seagate_SummitAS_SUMMITSUASG3.xml"],"Name":"Seagate_SummitAS_SUMMITSUASG3.fwpkg","SHA1Sum":"9e50a13bb4f3588e642c951b1fc94ac2574bb28f","SHA256Sum":"736327814937e6586bb8ca1efc10a0f4976fb53cd1d869e3c1217cbbecd0ba12","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-424d-3432-3030-30475945564b"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB24000GYEVK","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB24000GYEVK","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dcecd48f644944afa9df234dfe","SupportedDevices":["002340a5-424d-3432-3030-30475945564b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_5p0_PLDMoMCTP_80021BD4.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"5.00"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA2_SD_5p0_PLDMoMCTP_80021BD4.fwpkg","SHA1Sum":"cfa64822f50cb8c6802c82fc2eb98f2f69d8207b","SHA256Sum":"4327bce6a47b8f6d51fd78dc3ec10e795e2c383099849990cbd2f14c556ac5f1","SHA512Sum":"1e669aa3cc803d7ed2e4c6c999a9cf66d249cf4f9ecc4808437266075ea5da0fc97a1754df76720f6aa3624ad70998c2dfcecc24bb7ea2ed41e0c993da3c46e6"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_XXVDA2_SD_5p0_PLDMoMCTP_80021BD4.HPb","HPE_E810_XXVDA2_SD_5p0_PLDMoMCTP_80021BD4.xml","payload.json"],"Name":"HPE_E810_XXVDA2_SD_5p0_PLDMoMCTP_80021BD4.fwpkg","SHA1Sum":"cfa64822f50cb8c6802c82fc2eb98f2f69d8207b","SHA256Sum":"4327bce6a47b8f6d51fd78dc3ec10e795e2c383099849990cbd2f14c556ac5f1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860003"],"TypeOfChange":"1","Version":"5.00"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_406c15dcb0d2444fa3694dd1fd","SupportedDevices":["a6b1a447-382a-5a4f-8086-159b80860003"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e320db791d_0MPK78H5Q-2.1_amd64.deb","SHA1Sum":"9b687dca696b0233e3d1681c7ace71a18bf5af2b","SHA256Sum":"a348301f5bc40211e6bc5c3920c238afc05b99810331a373a489ae8f83c5550e","SHA512Sum":"ac90110b5586c19c91f3584ba5687574805e0621890026f04bf0dc83c5f685d8cf5e2dcd96b3461a11f277ec946c564a9852c5e0fe39aa2d14049eef074a8161"}],"ComponentSizeInKB":6751,"CompsigList":["firmware-hdd-e320db791d_0MPK78H5Q-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/CP071749.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/MPK78H5Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071749.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071749.scexe"],"Name":"firmware-hdd-e320db791d_0MPK78H5Q-2.1_amd64.deb","SHA1Sum":"9b687dca696b0233e3d1681c7ace71a18bf5af2b","SHA256Sum":"a348301f5bc40211e6bc5c3920c238afc05b99810331a373a489ae8f83c5550e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3 and MZXL57T6HALA-000H3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_38e0906f24c94ab59d7b8c2acf","SupportedDevices":["4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3830-3048d90154e8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"CP070948.zip","SHA1Sum":"e3f23fc0924c6a5d9614dccfea21818498a2cc94","SHA256Sum":"98a2fddb62a5f1d43c2bbd01408be501ae75cd03d5d957e1e390189d4f1ecabf","SHA512Sum":"4f8be1afb317fb8b41d784c389a53dd947cc8809e494aa59a0667677952de780e98f8f1fc235156242242cfb140c33a86b2d227f855e1aa4170c0e57d4c40013"}],"ComponentSizeInKB":17642,"CompsigList":["CP070948.compsig"],"FileList":["/CP070948_BUILD_4.data","/CP070948.vmexe64","/CP070948.vmfile","/CP070948_VMw.zip","/CP070948.xml","/payload.json","/CP070948_VMw.zip/index.xml","/CP070948_VMw.zip/vendor-index.xml","/CP070948_VMw.zip/metadata.zip","/CP070948_VMw.zip/vib20/CP070948/HPE_bootbank_CP070948_HPD9.4-8.0.0.20613240.vib","/CP070948_VMw.zip/metadata.zip/vendor-index.xml","/CP070948_VMw.zip/metadata.zip/vmware.xml","/CP070948_VMw.zip/metadata.zip/vibs/CP070948--3210713049238804245.xml","/CP070948_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070948_HPD9.4-8.0.0.20613240.xml"],"Name":"CP070948.zip","SHA1Sum":"e3f23fc0924c6a5d9614dccfea21818498a2cc94","SHA256Sum":"98a2fddb62a5f1d43c2bbd01408be501ae75cd03d5d957e1e390189d4f1ecabf","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP070948","Version":"HPD9.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9d44ca440cb54e9fb37887a240","SupportedDevices":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"cp068641.exe","SHA1Sum":"b0bb64448539df7575860edd075a005ac073f70d","SHA256Sum":"349ffe2cf282ec59c44ce0fcaf4d08087791ba0a51622fefe7b76dd7ed594836","SHA512Sum":"9ad7cd9b8e9cb21a7e735d80e18abcd20662d2f9bce8a9a822507780888ebedc9aebed0dc447cd16bca9cbaa084339aa89f016373488bf4ad1cc4eb629c1a9d1"}],"ComponentSizeInKB":5359,"CompsigList":["cp068641.compsig"],"FileList":["cp068641.xml","cpqsetup.exe","GPM173XAHPK6.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068641.exe","SHA1Sum":"b0bb64448539df7575860edd075a005ac073f70d","SHA256Sum":"349ffe2cf282ec59c44ce0fcaf4d08087791ba0a51622fefe7b76dd7ed594836","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_244a6149e7704ded8c87c64b7b","SupportedDevices":["4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43","562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U38_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073167.exe","SHA1Sum":"856869fe37e7996b0c79e3203e55fd9b3644398b","SHA256Sum":"fe31ad11858d501c5addd250df80e2ab5dd08757c688e9a509e4ea2ccb430cf5","SHA512Sum":"4c60a5946acd277558b270102e6dd40b40bddfb9c592e8810b1330be20c3534c24fc5cd481989fa896f087b1ea704340d581c2ee130303ccccf550c67a8e3d87"}],"ComponentSizeInKB":11479,"CompsigList":["cp073167.compsig"],"FileList":["cp073167.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U38_3.70_08_19_2026.signed.flash"],"Name":"cp073167.exe","SHA1Sum":"856869fe37e7996b0c79e3203e55fd9b3644398b","SHA256Sum":"fe31ad11858d501c5addd250df80e2ab5dd08757c688e9a509e4ea2ccb430cf5","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_49122d6d43a84106b9f899c2e3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U38","U38","U38","U38","U38"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"elx-lpfc-kmp-default-14.4.731.20_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"41122c6a92f7f0200ec1c09b91995bfc5e213a02","SHA256Sum":"5b789986d90cd0dd4bd93d6c12baa940fef3bc4a2d5b1eecab7dd8ed635ba2b8","SHA512Sum":"af9e8002f6216427efc01a7b24e2d0f8a234ac2270ad1d66d146577ec45d9e375e5b8a95b315b015ce0a4445f563d7ce5749b66ccf288651b84213977460dfd2"}],"ComponentSizeInKB":829,"CompsigList":["elx-lpfc-kmp-default-14.4.731.20_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"Name":"elx-lpfc-kmp-default-14.4.731.20_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"41122c6a92f7f0200ec1c09b91995bfc5e213a02","SHA256Sum":"5b789986d90cd0dd4bd93d6c12baa940fef3bc4a2d5b1eecab7dd8ed635ba2b8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_30b83a3f141d44b6818dcdc4fc","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068753.exe","SHA1Sum":"c6c1f62b8b5d694d6bdb316c02ae8a370552eabd","SHA256Sum":"a218f3c924a286b8f3aff9bdc3ae0e3c5fd60023d934fb224f10ffc18fe46c68","SHA512Sum":"5045883ca9edcc0ab61d55b5df9a3db122de1f2e432429cb7788b61d339521ec9fae8a28c80c81abf77c54cd4d82018d7a36de95df23a53cc33e8825f29f56f0"}],"ComponentSizeInKB":3552,"CompsigList":["cp068753.compsig"],"FileList":["cp068753.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WBCPssssASFD4.rel"],"Name":"cp068753.exe","SHA1Sum":"c6c1f62b8b5d694d6bdb316c02ae8a370552eabd","SHA256Sum":"a218f3c924a286b8f3aff9bdc3ae0e3c5fd60023d934fb224f10ffc18fe46c68","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cb7c7a062d0d46609b85b13dbd","SupportedDevices":["4d2340a5-304f-3630-3430-304a57554742","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3130-3630-304a57554656","452340a5-304f-3130-3630-304a57554745","4d2340a5-304f-3030-3830-304a57554655","452340a5-304f-3030-3830-304a57554744","4d2340a5-304f-3030-3430-304a57554654","452340a5-304f-3030-3430-304a57554743"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for M...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp070636.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"cp070639.exe","SHA1Sum":"f38244863bc18c58f90858e060ea40c01a3b9e22","SHA256Sum":"3db5de9eb23608b97a1af4a5ed2789d482d00bcf768a60b9c804f0d8004ca996","SHA512Sum":"b9f21a5ab4b7eb9572b5409343d04c7e296db8bfde9480e8e7c9314a4c5840a11160e62bfdb43970d0c5917187b5123eb168e4a9a74a09de6a7048d17fd7e960"}],"ComponentSizeInKB":2863,"CompsigList":["cp070639.compsig"],"FileList":["cp070636.compsig","cp070636.zip","cp070639.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp070639.exe","SHA1Sum":"f38244863bc18c58f90858e060ea40c01a3b9e22","SHA256Sum":"3db5de9eb23608b97a1af4a5ed2789d482d00bcf768a60b9c804f0d8004ca996","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant MicroServer Gen10 Plus v2","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_880be3d5af1c4f8f99ac655773","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U64"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL6WBA0HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-7f2a26e6d0-HPG5-2.1.x86_64.rpm","SHA1Sum":"8ee633d66388f51f6dbdf692acee6a3cca09fe0b","SHA256Sum":"d70b72abda2c89f21380c6e8ee37e2cc1fcb88498f1c09f096c4468bf21ed271","SHA512Sum":"2bc252d326090f5feb3c66e2b72876d237e545162bc3839ff2c035ddc2324b05724a217c4eebf663f7776eef4c089e2071795c2d4969b16124f066f7ee596a4b"}],"ComponentSizeInKB":6310,"CompsigList":["firmware-hdd-7f2a26e6d0-HPG5-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/CP073211.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/WVL6WBA0HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073211.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073211.scexe"],"Name":"firmware-hdd-7f2a26e6d0-HPG5-2.1.x86_64.rpm","SHA1Sum":"8ee633d66388f51f6dbdf692acee6a3cca09fe0b","SHA256Sum":"d70b72abda2c89f21380c6e8ee37e2cc1fcb88498f1c09f096c4468bf21ed271","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000GWKGR Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_47a6ade1e9fe40d6b3df8f2b8d","SupportedDevices":["4d2340a5-3042-3630-3030-3047574b4752"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d815900212","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee15900212","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef15900212","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d81590020c","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ee1590020c","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ef1590020c","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d615900230","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16de15900230","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c3","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c3","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c3","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d7159002c5","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec159002c5","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed159002c5","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d715900211","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec15900211","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed15900211","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16d71590020e","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ec1590020e","Version":"238.1.169000"},{"DeviceName":"HPE Broadcom NetXtreme-E adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"bcm238.1.169000.Optimized.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-16ed1590020e","Version":"238.1.169000"}]},"Files":[{"Checksum":[{"Filename":"bcm238.1.169000.Optimized.fwpkg","SHA1Sum":"98311d55229876a035f167e3fbace52cc9e7a255","SHA256Sum":"943df0c2c16a92adb2177a01d8d680953164ad688171a6f5ba63c8f7b33f7a08","SHA512Sum":"64c351a8d43c074d9aed19f0a4e7754f71a29d0d9424ba69837e7852c5099c819a3cf937934156ffdd4f2fef43ee8797b36376940b5698830244cb176857c488"}],"ComponentSizeInKB":8490,"CompsigList":[],"FileList":["bcm238.1.169000.Optimized.HPb","bcm238.1.169000.Optimized.xml","payload.json"],"Name":"bcm238.1.169000.Optimized.fwpkg","SHA1Sum":"98311d55229876a035f167e3fbace52cc9e7a255","SHA256Sum":"943df0c2c16a92adb2177a01d8d680953164ad688171a6f5ba63c8f7b33f7a08","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16d615900230","a6b1a447-382a-5a4f-14e4-16de15900230","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"TypeOfChange":"1","Version":"238.1.169000"}],"InstallationDependency":{},"MinimumActiveVersion":"226.1.107000","Name":"HPE Broadcom NetXtreme-E Firmware Package for BCM5741x adapters","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"NIC_NXE_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_40a08dc677f24d76995d52acee","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","U40","U39","U64"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-12304c1aca-HPG6-6.1.x86_64.rpm","SHA1Sum":"37516b67c70e4d7b7b2a7de23a8b1d431da3cac2","SHA256Sum":"0f289e6023ec56dc97fdf3b086eb1ef5e2bebd0b3fd03c46c3a7a7996ac75502","SHA512Sum":"9f42c38c1912d171f1015124e2868dfb922518ba97b130a1e0ae8b16e1c0e00c799c5da849aeb1c62871e0cd526756385bd9b570f826037df1d687b3f79b27c9"}],"ComponentSizeInKB":5643,"CompsigList":["firmware-hdd-12304c1aca-HPG6-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/CP068937.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/SCIMARRNNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068937.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068937.scexe"],"Name":"firmware-hdd-12304c1aca-HPG6-6.1.x86_64.rpm","SHA1Sum":"37516b67c70e4d7b7b2a7de23a8b1d431da3cac2","SHA256Sum":"0f289e6023ec56dc97fdf3b086eb1ef5e2bebd0b3fd03c46c3a7a7996ac75502","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aeeaaa3ea8b3407f9705db0c96","SupportedDevices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Files":[{"Checksum":[{"Filename":"CP070835.zip","SHA1Sum":"98e5bf69e1b08d7c4cda82b4b3e19a17bd64f5b2","SHA256Sum":"5e74b31d66b7378b5eac0ca8d9d7993562c298b3685ca97ea0850586f068c038","SHA512Sum":"aa2c20b0bbc4e5a9d35b5dde803044795ce818d8801f95ba3ca65472c5c4ffbb4ca376d8de16f8913a18ade7ee2c1e170732f810244415e627c4225ad3b520ff"}],"ComponentSizeInKB":17975,"CompsigList":["CP070835.compsig"],"FileList":["/CP070835_BUILD_2.data","/CP070835.vmexe64","/CP070835.vmfile","/CP070835_VMw.zip","/CP070835.xml","/payload.json","/CP070835_VMw.zip/index.xml","/CP070835_VMw.zip/vendor-index.xml","/CP070835_VMw.zip/metadata.zip","/CP070835_VMw.zip/vib20/CP070835/HPE_bootbank_CP070835_HPG7.2-8.0.0.20613240.vib","/CP070835_VMw.zip/metadata.zip/vendor-index.xml","/CP070835_VMw.zip/metadata.zip/vmware.xml","/CP070835_VMw.zip/metadata.zip/vibs/CP070835-7004686765859091396.xml","/CP070835_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070835_HPG7.2-8.0.0.20613240.xml"],"Name":"CP070835.zip","SHA1Sum":"98e5bf69e1b08d7c4cda82b4b3e19a17bd64f5b2","SHA256Sum":"5e74b31d66b7378b5eac0ca8d9d7993562c298b3685ca97ea0850586f068c038","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7","VibList":[{"Name":"CP070835","Version":"HPG7.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e39f1ca7652a4f25ac5993e9b3","SupportedDevices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-fastlinq-8.76.6.0-1.rhel10u1.x86_64.rpm","SHA1Sum":"01c469f3a9c111055e999009e5ed0a28343c0345","SHA256Sum":"9cc3db5171d9dd6f3947f8b9f4e8708342c0f3e52c936a3572a925fcf365e2cf","SHA512Sum":"273c82d8a1acc6c10bb16991f130c7cee1897cac93a9e7849cb13a9c865b9bf1672b780f7994c8154c55231005876cc6ae5796a9c04a2d6de9cb16a6913ce3f4"}],"ComponentSizeInKB":17548,"CompsigList":["kmod-qlgc-fastlinq-8.76.6.0-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"Name":"kmod-qlgc-fastlinq-8.76.6.0-1.rhel10u1.x86_64.rpm","SHA1Sum":"01c469f3a9c111055e999009e5ed0a28343c0345","SHA256Sum":"9cc3db5171d9dd6f3947f8b9f4e8708342c0f3e52c936a3572a925fcf365e2cf","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.6.0-5"},{"Checksum":[{"Filename":"kmod-qlgc-fastlinq-8.76.6.0-5.rhel10u2.x86_64.rpm","SHA1Sum":"349378bd7b7869b1ea13ba076cbccbe326b0cb93","SHA256Sum":"0ff435b34f80d4acddb9e554dd0640f3da450b5763478a5ed3797c8dcf52bd32","SHA512Sum":"288f4683fee2077755fc8408ca38ea3661223db5bd1f726b44485b92ddec83f29180708cf70940138612fea39d143a14f522ff869d0db314b8a7f5165e455f10"}],"ComponentSizeInKB":18035,"CompsigList":["kmod-qlgc-fastlinq-8.76.6.0-5.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-fastlinq","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"Name":"kmod-qlgc-fastlinq-8.76.6.0-5.rhel10u2.x86_64.rpm","SHA1Sum":"349378bd7b7869b1ea13ba076cbccbe326b0cb93","SHA256Sum":"0ff435b34f80d4acddb9e554dd0640f3da450b5763478a5ed3797c8dcf52bd32","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.6.0-5"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7119b11d97e4419a8c8007dcef","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069555.exe","SHA1Sum":"24c02f01035020d7f566addc560bcbc1e3d905aa","SHA256Sum":"cf9f66125d626cb6777d05e4779d150fd30d923ce400f590dc084ce4ef833139","SHA512Sum":"e61e022720ad98f8a3b8d488a344fa81c3fce687ded51b36e7b02219e72242ae68b1cfe5f6911b99c27f5033bbaec2e6fbb07029485ce43e57a9450b0b470212"}],"ComponentSizeInKB":833,"CompsigList":["cp069555.compsig"],"FileList":["cp069555.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxn68x64.cat","vxn68x64.din","vxn68x64.inf","vxn68x64.sys","vxnmsg.dll"],"Name":"cp069555.exe","SHA1Sum":"24c02f01035020d7f566addc560bcbc1e3d905aa","SHA256Sum":"cf9f66125d626cb6777d05e4779d150fd30d923ce400f590dc084ce4ef833139","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec40e07a7c"],"TypeOfChange":"1","Version":"2.1.252.0"}],"InstallationDependency":{},"Name":"HPE Intel vxn Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"vxn68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6d1aec5f11a746129491eab02c","SupportedDevices":["a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-10ed103c211b","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U41","U33","U40","U37","U38","A41","O43","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"cp068645.exe","SHA1Sum":"9a3a29fd48c789bb108eeabe590b28c5db3d2691","SHA256Sum":"80b2098234f5ffbb9dbd3d2899b59fcbca686a97a037ad4d22cd3cccbca9b87d","SHA512Sum":"e903ceed6523ddba67ff5789f9db5bac172569b0d2f7e453583afbaa71a354358dabd85bfad41f77ede94b53f20176ae6b986ad9e6e09baac8a67bfcdf96bbdb"}],"ComponentSizeInKB":4326,"CompsigList":["cp068645.compsig"],"FileList":["cp068645.xml","cpqsetup.exe","KACD6ALSGPK8.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068645.exe","SHA1Sum":"9a3a29fd48c789bb108eeabe590b28c5db3d2691","SHA256Sum":"80b2098234f5ffbb9dbd3d2899b59fcbca686a97a037ad4d22cd3cccbca9b87d","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_11806acbfb014d739d8e94a6b5","SupportedDevices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c31355433"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-951aefd63e-MPK7825Q-6.1.x86_64.rpm","SHA1Sum":"e104b26a880d4d30af200bc6fdd0912905b2c932","SHA256Sum":"38a96575f91b2ebf28e56cc1ef947119f00cf3eb99842324c1c351cc1c7c0361","SHA512Sum":"09d645265e80f413b4f0a90e1eaf58b76248ff578a168b69707a1e219025982c3dd566e54675ddbab56e045551185339108c9ed870121d2aeafbe3125bc4568c"}],"ComponentSizeInKB":9631,"CompsigList":["firmware-hdd-951aefd63e-MPK7825Q-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/CP068915.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/MPK7825Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068915.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068915.scexe"],"Name":"firmware-hdd-951aefd63e-MPK7825Q-6.1.x86_64.rpm","SHA1Sum":"e104b26a880d4d30af200bc6fdd0912905b2c932","SHA256Sum":"38a96575f91b2ebf28e56cc1ef947119f00cf3eb99842324c1c351cc1c7c0361","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-000H3 Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3c7883e497ac44e0bd4a809faf","SupportedDevices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U30_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U30_3.70_08_19_2026.fwpkg","SHA1Sum":"00e7374e40f5ccb2aa2b60f4ef5afe9abdc0d9f2","SHA256Sum":"85e7c708e506ada7d3004f5b722fcd91c5c7fca04c4be3a28518a436c0ab074f","SHA512Sum":"c9b3f233234edb7edac6985b0c72158bf974085e78b5ea3146929a9dad74aedb150d5d56cd97091f3573fe1b1494054c756979ec0c0528181dcb2cd39a0b92d0"}],"ComponentSizeInKB":32829,"CompsigList":[],"FileList":["payload.json","U30_3.70_08_19_2026.signed.flash","U30_3.70_08_19_2026.xml"],"Name":"U30_3.70_08_19_2026.fwpkg","SHA1Sum":"00e7374e40f5ccb2aa2b60f4ef5afe9abdc0d9f2","SHA256Sum":"85e7c708e506ada7d3004f5b722fcd91c5c7fca04c4be3a28518a436c0ab074f","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL380 Gen10 (U30) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_36c9d2a2e7254230aed2d56873","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U30"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072688.exe","SHA1Sum":"4c5f6f5846e5e923324849d640ec7c5ba3f02bc4","SHA256Sum":"3f5ca1a321ca0e43eff2357ea614b3ba7febfb0e081751a332e7191591fab267","SHA512Sum":"84399ef686e8665d3aac150d92b9c2548f4063aaccd4514ad33d4b01756fd06d967d15c95cb716061a5c98727a90d6941ba061674012a9339a3b5934652f9a5a"}],"ComponentSizeInKB":1100,"CompsigList":["cp072688.compsig"],"FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.sys","cp072688.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp072688.exe","SHA1Sum":"4c5f6f5846e5e923324849d640ec7c5ba3f02bc4","SHA256Sum":"3f5ca1a321ca0e43eff2357ea614b3ba7febfb0e081751a332e7191591fab267","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"238.1.110.0"}],"InstallationDependency":{},"Name":"Broadcom NetXtreme-E Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a972f020af444fc7930ea0cfb6","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16c514e41593","a6b1a447-382a-5a4f-14e4-16c514e41592","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-181b14e4e124","a6b1a447-382a-5a4f-14e4-181b14e4e324","a6b1a447-382a-5a4f-14e4-16bd14e41593","a6b1a447-382a-5a4f-14e4-16bd14e41592","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-181b14e4e124","a6b1a447-382a-5a4f-14e4-181b14e4e324","a6b1a447-382a-5a4f-14e4-16bd14e41595","a6b1a447-382a-5a4f-14e4-16bd14e41594","a6b1a447-382a-5a4f-14e4-16bd14e41597","a6b1a447-382a-5a4f-14e4-16bd14e41596","a6b1a447-382a-5a4f-14e4-16c514e41595","a6b1a447-382a-5a4f-14e4-16c514e41594","a6b1a447-382a-5a4f-14e4-16c514e41597","a6b1a447-382a-5a4f-14e4-16c514e41596","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc14e416d8","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14e4-181914e41760","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14e4-16dc14e416d6","a6b1a447-382a-5a4f-14e4-16dc14e416d7","a6b1a447-382a-5a4f-14e4-16dc14e41593","a6b1a447-382a-5a4f-14e4-16dc14e41592","a6b1a447-382a-5a4f-14e4-181914e4e124","a6b1a447-382a-5a4f-14e4-181914e4e324","a6b1a447-382a-5a4f-14e4-16c114e41593","a6b1a447-382a-5a4f-14e4-16c114e41592","a6b1a447-382a-5a4f-14e4-181914e4e124","a6b1a447-382a-5a4f-14e4-181914e4e324","a6b1a447-382a-5a4f-14e4-16c114e41595","a6b1a447-382a-5a4f-14e4-16c114e41594","a6b1a447-382a-5a4f-14e4-16c114e41597","a6b1a447-382a-5a4f-14e4-16c114e41596","a6b1a447-382a-5a4f-14e4-16dc14e41595","a6b1a447-382a-5a4f-14e4-16dc14e41594","a6b1a447-382a-5a4f-14e4-16dc14e41597","a6b1a447-382a-5a4f-14e4-16dc14e41596","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180814e41599","a6b1a447-382a-5a4f-14e4-180814e41598","a6b1a447-382a-5a4f-14e4-180914e41599","a6b1a447-382a-5a4f-14e4-180914e41598","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-180614e41751","a6b1a447-382a-5a4f-14e4-180614e41599","a6b1a447-382a-5a4f-14e4-180614e41598","a6b1a447-382a-5a4f-14e4-180714e41599","a6b1a447-382a-5a4f-14e4-180714e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14E4-180800000000","a6b1a447-382a-5a4f-14E4-181B00000000","a6b1a447-382a-5a4f-14E4-180900000000","a6b1a447-382a-5a4f-14E4-181B00000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U50","U39","02020001","03020101","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","H10","H10","H10","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U41_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073180.exe","SHA1Sum":"c409674148769886d44ff310f90d7a846f73d540","SHA256Sum":"251c273539b33c15e04d588dba9ffc869e2d945535e074a6cf92e2ec63240f7b","SHA512Sum":"0187ce5248e565dab7d3f1ce1b28fa8a5ddeb625246b1d5459b862b1036decef11232c8618aed1821ec3406b0ee1a4a3abcff82e41166c983491744a72259106"}],"ComponentSizeInKB":11248,"CompsigList":["cp073180.compsig"],"FileList":["cp073180.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U41_3.70_08_19_2026.signed.flash"],"Name":"cp073180.exe","SHA1Sum":"c409674148769886d44ff310f90d7a846f73d540","SHA256Sum":"251c273539b33c15e04d588dba9ffc869e2d945535e074a6cf92e2ec63240f7b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML350 Gen10 (U41) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_860853a88d04446f9ef6a25161","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U41"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072194.exe","SHA1Sum":"bdec293e21f03241085289c2782131ff9f908c16","SHA256Sum":"0e51ebcd369d2e1a1330fca8f7af721585a3622634826f7c94466fd361efa99f","SHA512Sum":"a68cfc09871c47f0438be68d80571f873442dc7d7f4f58db17cb3a48569c9463b65ef7d5a7695e504bdb4a7e6c1f57d0854e2d306cf980d1d5f30054289c3859"}],"ComponentSizeInKB":2432,"CompsigList":["cp072194.compsig"],"FileList":["cp072194.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072194.exe","SHA1Sum":"bdec293e21f03241085289c2782131ff9f908c16","SHA256Sum":"0e51ebcd369d2e1a1330fca8f7af721585a3622634826f7c94466fd361efa99f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"Mellanox WinOF2 Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cae1e2a7f96f4f1ab1031483d8","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101815b30117","a6b1a447-382a-5a4f-15b3-101e15b30040","a6b1a447-382a-5a4f-15b3-101e15b30042","a6b1a447-382a-5a4f-15b3-101615b30102","a6b1a447-382a-5a4f-15b3-101615b30047","a6b1a447-382a-5a4f-15b3-101815b30116","a6b1a447-382a-5a4f-15b3-101815b30052","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101e15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101e15b30007"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","U47","A46","U47","U48","U47","U50","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U70","U66","U71","U72","U68","A59","U72","A66","A66","U77","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505a57534c","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30505a57534e","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30505a575350","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30505a584642","Version":"HPD4"},{"DeviceName":"Samsung-PM165X-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM165X_GPM1653SAMD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-30505a584555","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"Samsung_PM165X_GPM1653SAMD4.fwpkg","SHA1Sum":"3e486a890f623ff9eb2aa10cb1c42554675bd7a9","SHA256Sum":"35feb07648f869b17ebe0c4406d5c1d0aec7cf665a48250be9663162ddb20aeb","SHA512Sum":"6847ff9e59d2bf533a5b81090d2fd41790e79be1f5209a19ccc8c68730845552e9816df0e5bd0ad9ba4326645b508ed7f091877ef49e8c8954600f5f3fc4cea9"}],"ComponentSizeInKB":1948,"CompsigList":[],"FileList":["payload.json","Samsung_PM165X_GPM1653SAMD4.HPb","Samsung_PM165X_GPM1653SAMD4.xml"],"Name":"Samsung_PM165X_GPM1653SAMD4.fwpkg","SHA1Sum":"3e486a890f623ff9eb2aa10cb1c42554675bd7a9","SHA256Sum":"35feb07648f869b17ebe0c4406d5c1d0aec7cf665a48250be9663162ddb20aeb","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-30505a57534c","562340a5-304f-3130-3932-30505a57534e","562340a5-304f-3330-3834-30505a575350","562340a5-304f-3730-3638-30505a584642","562340a5-304f-3531-3336-30505a584555"],"TypeOfChange":"2","Version":"HPD4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - VO000960PZWSL, VO001920PZWSN, VO003840PZWSP, VO007680PZXFB and VO015360PZXEU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960PZWSL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920PZWSN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PZWSP","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PZXFB","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO015360PZXEU","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ddbc160c7a4b4f22b8db349e39","SupportedDevices":["562340a5-304f-3030-3936-30505a57534c","562340a5-304f-3130-3932-30505a57534e","562340a5-304f-3330-3834-30505a575350","562340a5-304f-3730-3638-30505a584642","562340a5-304f-3531-3336-30505a584555"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"WDC-ParisD-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"WDC_ParisD_WPDQTK90HPG2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3032-3030-3047584d5656","Version":"HPG2"}]},"Files":[{"Checksum":[{"Filename":"WDC_ParisD_WPDQTK90HPG2.fwpkg","SHA1Sum":"fce0a3bfd666d37204ac0b5a9945dec77aafe58c","SHA256Sum":"102fafc3cdbf0e3bb763d93d8ed34705647951b17272755c545f4badab665420","SHA512Sum":"09c5098ef1ccc8491766015c23d61c09d59ee6840a2b792f5dca54364f8a93ab786bba7d71ca60fe2033a9e68ad340fccfd9fdf6371a85f1e9af2e73421c3c9b"}],"ComponentSizeInKB":7059,"CompsigList":[],"FileList":["payload.json","WDC_ParisD_WPDQTK90HPG2.HPb","WDC_ParisD_WPDQTK90HPG2.xml"],"Name":"WDC_ParisD_WPDQTK90HPG2.fwpkg","SHA1Sum":"fce0a3bfd666d37204ac0b5a9945dec77aafe58c","SHA256Sum":"102fafc3cdbf0e3bb763d93d8ed34705647951b17272755c545f4badab665420","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3032-3030-3047584d5656"],"TypeOfChange":"1","Version":"HPG2"}],"InstallationDependency":{},"Name":"Universal Firmware Package for Drives - MB020000GXMVV","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000GXMVV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_511886ad94e74f72b769198052","SupportedDevices":["4d2340a5-3042-3032-3030-3047584d5656"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","7.0","15.0","9.0","16.0","10.0","26.04","24.04"]},{"OS":"VMware","Version":["8.0","9.0","9.1"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u7.x86_64.rpm","SHA1Sum":"706e583477a7e996f71e9b1044822e0d48ca013e","SHA256Sum":"3482450d5607fe67b35a712ad0b30121877c1261d46cb4bca171f9f28af9999d","SHA512Sum":"0f65ae381db703dcb22ace23464191e301ff7bea60e1cdef5e03111dd13841eed19a5ee904db711123ab2ad8ec9c9cb57c3bbcd650fdcc590573b97b9e040d7d"}],"ComponentSizeInKB":2639,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u7.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/06","./usr/lib/.build-id/06/c91c827e1c797a4ecb27d3e6a56d84b74d22df","./usr/lib/.build-id/10","./usr/lib/.build-id/10/d947fac5ec503d927e58fdfa821a634829738e","./usr/lib/.build-id/16","./usr/lib/.build-id/16/bfa88252e0d166cd5142998f8e863fe0c8fff8","./usr/lib/.build-id/1e","./usr/lib/.build-id/1e/f05f986f49aa67602464f7e33bf768f1614fae","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/48767f2130a07febc84c74cb5fa7a9620e64de","./usr/lib/.build-id/40","./usr/lib/.build-id/40/a3981455e5891a562f0fd698351a0f02bba6ae","./usr/lib/.build-id/4a","./usr/lib/.build-id/4a/0e36cb854a52462d7e096baf4fd6efaa3af81f","./usr/lib/.build-id/4f","./usr/lib/.build-id/4f/528ea5eb8f7481b97d12c44e480dd4d3e36026","./usr/lib/.build-id/60","./usr/lib/.build-id/60/26c9c6dafc8ae663e32176881a01f7b2c950ee","./usr/lib/.build-id/64","./usr/lib/.build-id/64/22de79525b447ddb1448745f5d8635f9e32fcb","./usr/lib/.build-id/69","./usr/lib/.build-id/69/e6b7a70d8da5c1666fce5e0fc1e1e1a8659184","./usr/lib/.build-id/87","./usr/lib/.build-id/87/f7169e8759f0e55131800404777eff6aa87655","./usr/lib/.build-id/88","./usr/lib/.build-id/88/7f1fd08f5cf3bc68002b8e4d98041e537bd2d9","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/4d69ff3b5f35a79957a59da55975a9fb1f7eab","./usr/lib/.build-id/91","./usr/lib/.build-id/91/03097315ab544a74dd3027ff83d1ddf7d12640","./usr/lib/.build-id/94","./usr/lib/.build-id/94/8aad76812eeaf5cf8dfea3b66aaeec21c00b3c","./usr/lib/.build-id/a3","./usr/lib/.build-id/a3/aac8cc43a7b1ae248e693e47d5b17298f52127","./usr/lib/.build-id/a7","./usr/lib/.build-id/a7/b1abfeaa9011b0db9af18f2b3be92b6eecdc2f","./usr/lib/.build-id/ad","./usr/lib/.build-id/ad/c70fdf8790b5999a7b560aac69680db7ed2fe7","./usr/lib/.build-id/c0","./usr/lib/.build-id/c0/ff1f3f8335059454c4aabac82dc7040fa04881","./usr/lib/.build-id/cd","./usr/lib/.build-id/cd/0c01094285274e728b2160a1cce6afb805bc12","./usr/lib/.build-id/df","./usr/lib/.build-id/df/8140d774c81739357a45be24834702d609e668","./usr/lib/.build-id/e2","./usr/lib/.build-id/e2/4e91897066b8f592a295c0a7fba68dfec65156","./usr/lib/.build-id/f5","./usr/lib/.build-id/f5/92e5dfc914e9e6ba53a93380a805d39f77e168","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.8.84","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/libvma","./usr/share/doc/libvma/CHANGES","./usr/share/doc/libvma/README","./usr/share/doc/mlnx-ofa_kernel","./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/perftest","./usr/share/doc/perftest/COPYING","./usr/share/doc/perftest/README","./usr/share/doc/perftest/runme","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/libvma","./usr/share/licenses/libvma/LICENSE","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u7.x86_64.rpm","SHA1Sum":"706e583477a7e996f71e9b1044822e0d48ca013e","SHA256Sum":"3482450d5607fe67b35a712ad0b30121877c1261d46cb4bca171f9f28af9999d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u7.x86_64.rpm","SHA1Sum":"b8aa9f57a4f706d4143aa8f5690c6ee2fd7e9e05","SHA256Sum":"078a3186b7835a03421a76383bbae57a29617cf4e549835b4a6984394c115782","SHA512Sum":"f22ea14f77a10b773ce66ee2aaaea61bc34b4e00a6afe0f6308e4d4eb9774324dc82516e2cbefd95463f8aa8ee9b0f242256155a6c754f4794e81ac0a5228105"}],"ComponentSizeInKB":2751,"CompsigList":["kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/lib/.build-id","./usr/lib/.build-id/03","./usr/lib/.build-id/03/ca921d2fe77722e760b930268fb2670170af32","./usr/lib/.build-id/08","./usr/lib/.build-id/08/baad327f9d93c712e9a2f70872401f83bb2610","./usr/lib/.build-id/0f","./usr/lib/.build-id/0f/d83fb3a1a9ce47ed1981e64f9168d33cf007ab","./usr/lib/.build-id/11","./usr/lib/.build-id/11/06e45f9c6dd63b0f749e014e6b4821eb528b85","./usr/lib/.build-id/11/6ed93595afb4ff5cdcee3c83ed9cacfb6643dc","./usr/lib/.build-id/12","./usr/lib/.build-id/12/e8a74bb3ef71c820a2f9a798f380c85f046e04","./usr/lib/.build-id/1e","./usr/lib/.build-id/1e/f81423a6ed6bbbcf4d6500e25e4ae95a101f78","./usr/lib/.build-id/1f","./usr/lib/.build-id/1f/5afa2155c8bf34ad4cbfbf07c092301b6d425e","./usr/lib/.build-id/21","./usr/lib/.build-id/21/a3e72c8cc6ffcbdb5a2fe1aa0a1698c884f121","./usr/lib/.build-id/24","./usr/lib/.build-id/24/3c71a5ce053703c57ae72bff7ff3edaa8b70ef","./usr/lib/.build-id/29","./usr/lib/.build-id/29/bc9ac72374bf1ead7d7fbb3a68586525f8d122","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/3597a25617829251fe6575e48303e5d779f635","./usr/lib/.build-id/2f","./usr/lib/.build-id/2f/50e6da4622e9c37dcbcda8a03bbc16f0e3003e","./usr/lib/.build-id/35","./usr/lib/.build-id/35/474bed860e0c9464ee2ffeb7c27ed242b9cd71","./usr/lib/.build-id/39","./usr/lib/.build-id/39/d5b8f283de89dcbec0a80d65f715c9dddb32be","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/e840f9b65b5094da00b10c4e7882a20afc8e87","./usr/lib/.build-id/46","./usr/lib/.build-id/46/40ee3a443f92e3798c917d3da419d51231f59d","./usr/lib/.build-id/5b","./usr/lib/.build-id/5b/c55c12c1a7d2d0b1812c40111ba4af0a9104da","./usr/lib/.build-id/60","./usr/lib/.build-id/60/41505d735f13a982046a232aadec3d8c25a697","./usr/lib/.build-id/66","./usr/lib/.build-id/66/2367f423960b6da7701bdea49460f12224c51c","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/58de3cbc4ed51441d7eed34781b1d679f8edd2","./usr/lib/.build-id/71","./usr/lib/.build-id/71/7bda78ce72488fce8a128d5d85fcb1f6953536","./usr/lib/.build-id/74","./usr/lib/.build-id/74/d6e21fb55d9070408b241aaff1b5a7e5552bc6","./usr/lib/.build-id/75","./usr/lib/.build-id/75/f992ae2b6fcc108f2d4a6cd47aeb3d7fcb9ff0","./usr/lib/.build-id/81","./usr/lib/.build-id/81/e5bccf1d755ea4b810497b0e86b837be8c498b","./usr/lib/.build-id/ab","./usr/lib/.build-id/ab/4ce8a002c51911c919c0d0d1ea36bec960e585","./usr/lib/.build-id/ba","./usr/lib/.build-id/ba/64fa1e1ee642e6bc52da2c3d1f59b17c09d228","./usr/lib/.build-id/be","./usr/lib/.build-id/be/7f853647e0584031e9002c3c33875cef4229c1","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/4f18e7bbf2dc66414d18abe38d2a1a5448efcd","./usr/lib/.build-id/d0","./usr/lib/.build-id/d0/51f1fbd417dc91655307268c5bae1dd7f72fc4","./usr/lib/.build-id/d0/7245b776b35d1241b8a63455719ac554428bd8","./usr/lib/.build-id/d7","./usr/lib/.build-id/d7/7364aa3b349f13140e4c810505526efb67bd02","./usr/lib/.build-id/da","./usr/lib/.build-id/da/759ed4c2819545b30c116944cd70a9a6d9ba7c","./usr/lib/.build-id/da/a6ac4851ddaa965a909dea5bb446fe02a8c5cc","./usr/lib/.build-id/dc","./usr/lib/.build-id/dc/59fbb1b9f5de83ecfd0f0519013a21d90babc5","./usr/lib/.build-id/e0","./usr/lib/.build-id/e0/821c08e13b6c839c67a9cf6deec92e22bbdd18","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/95eb07d5f89a040769eb65a627ec377a7f4674","./usr/lib/.build-id/ed","./usr/lib/.build-id/ed/1d242776d2ebc978fa45b360b2bab6e52746d9","./usr/lib/.build-id/ee","./usr/lib/.build-id/ee/001a94655a76cb7d2f5ece0b2a2da20ebc0e34","./usr/lib/.build-id/f0","./usr/lib/.build-id/f0/a04857415e7ae02b2474119c93ea38293aa4eb","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/5cc6c4bc5520aa7f6f9cce5d641e8108af5ef6","./usr/lib/.build-id/fc","./usr/lib/.build-id/fc/2014543b4c6ddce1deb4359d19b90a578d0df0","./usr/lib/.build-id/fd","./usr/lib/.build-id/fd/6c6f116d2eaf63fef96b9268c47e36a4595e45","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"Name":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u7.x86_64.rpm","SHA1Sum":"b8aa9f57a4f706d4143aa8f5690c6ee2fd7e9e05","SHA256Sum":"078a3186b7835a03421a76383bbae57a29617cf4e549835b4a6984394c115782","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"Name":"Linux","Value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"Name":"Linux","Value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"Name":"Linux","Value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"Name":"Linux","Value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 9 Update 7 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4c6e93ae47304847bd2c986692","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE e910 QSFP+ 4x10G Network Riser","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Backplane_4x10G_NCSI_4p30_80001A42.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37ce80860000","Version":"1.2684"},{"DeviceName":"HPE e910 1G RJ45 Network Rsr","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37d180860000","Version":"1.2684"},{"DeviceName":"HPE e910 2p 10GbE SFP+ Mod","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37d380860000","Version":"1.2684"}]},"Files":[{"Checksum":[{"Filename":"cp070383.exe","SHA1Sum":"e2fcbfeb56241899a7330bcb8ed4511a18f3c3e8","SHA256Sum":"fdf19b3027d88f840dfd5d9db30a427869cbc289e135d263f985966b819f1e3d","SHA512Sum":"97d3c19629af027d7114e1cc843013ea715cbb96f572fe9e79375876ef351afdfc47f73410945a467990669663a368db47939009d77b093060aac9917a5b7099"}],"ComponentSizeInKB":10750,"CompsigList":["cp070383.compsig"],"FileList":["BootIMG.FLB","cp070383.xml","cpqsetup.exe","ilorest_chif.dll","Immediate_offset_1.txt","Immediate_offset_2.txt","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","iSCSI.txt","iv.txt","LBG_B2_Backplane_4x10G_NCSI_4p30_80001FC8.bin","LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001FE8.bin","nvmupdatew64e.exe","OCP_Configuration.txt","payload.json","payload_version.txt","QSFP.cfg","RJ45.cfg","SFP.cfg","version.txt"],"Name":"cp070383.exe","SHA1Sum":"e2fcbfeb56241899a7330bcb8ed4511a18f3c3e8","SHA256Sum":"fdf19b3027d88f840dfd5d9db30a427869cbc289e135d263f985966b819f1e3d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37ce80860000","a6b1a447-382a-5a4f-8086-37d180860000","a6b1a447-382a-5a4f-8086-37d380860000"],"TypeOfChange":"1","Version":"4.30"}],"InstallationDependency":{},"Name":"HPE Edgeline X722 NIC Firmware Component for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"x722","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_66b90de597c94dbfaf7482bc51","SupportedDevices":["a6b1a447-382a-5a4f-8086-37D380860000","a6b1a447-382a-5a4f-8086-37D180860000","a6b1a447-382a-5a4f-8086-37CE80860000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-ixgbe-6.4.4-1.rhel9u7.x86_64.rpm","SHA1Sum":"ddcbe5460564ae7cb95121a82d24001222543354","SHA256Sum":"9f9f55cbf1d735c5e8c7ea52d9a6d28e38dd9356d6bdbae0072abd0d32a80a2f","SHA512Sum":"8c271eac9e41d3b22ac0e8c1c2b9117b1b4fa2dd468a11a093c7706724d0af7b1d576043d59f8e41f55cc923c16a23f67a41d3e8ae9880334cd7b8f6bd6cb2a0"}],"ComponentSizeInKB":381,"CompsigList":["kmod-hp-ixgbe-6.4.4-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbe","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/01","./usr/lib/.build-id/01/3b2a02fa853d5437909975b78dd6581b51d3ab","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"Name":"kmod-hp-ixgbe-6.4.4-1.rhel9u7.x86_64.rpm","SHA1Sum":"ddcbe5460564ae7cb95121a82d24001222543354","SHA256Sum":"9f9f55cbf1d735c5e8c7ea52d9a6d28e38dd9356d6bdbae0072abd0d32a80a2f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"TypeOfChange":"1","Version":"6.4.4-1"},{"Checksum":[{"Filename":"kmod-hp-ixgbe-6.4.4-1.rhel9u8.x86_64.rpm","SHA1Sum":"e87955c028782a3e09e3a871ba39e08607a9d4fa","SHA256Sum":"1181891859e640b9fb36e7e21198d83fc3937cb8e478e737d52e5b12c8a1bfe3","SHA512Sum":"5c27113a2df7915d0eca2a3d22b39b6387fabaf038c8455efaa351910f53f0b651e9a9a3b88039035ce15f76ecc5d0c3d7d2bb04eff2259c7c657fbb644e2309"}],"ComponentSizeInKB":375,"CompsigList":["kmod-hp-ixgbe-6.4.4-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-ixgbe","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-ixgbe/ixgbe.ko","./usr/lib/.build-id","./usr/lib/.build-id/92","./usr/lib/.build-id/92/f57ee87985ec4019cc2c352605143a5f221b23","./usr/share/smartupdate/kmod-hp-ixgbe/component.xml"],"Name":"kmod-hp-ixgbe-6.4.4-1.rhel9u8.x86_64.rpm","SHA1Sum":"e87955c028782a3e09e3a871ba39e08607a9d4fa","SHA256Sum":"1181891859e640b9fb36e7e21198d83fc3937cb8e478e737d52e5b12c8a1bfe3","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccba99d79"],"TypeOfChange":"1","Version":"6.4.4-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-ixgbe","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7d4c1933a9a04d07941d18e4b7","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_OCP_5p0_NCSIwPLDMoMCTP_80021BD1.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"5.00"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_CQDA2_OCP_5p0_NCSIwPLDMoMCTP_80021BD1.fwpkg","SHA1Sum":"fb91851c5eda36659721c8fdbe738d93344d0fe2","SHA256Sum":"162e5e6459f3054192f84fb2f154fbfc9c09cc01b474a94c58249a47a902d191","SHA512Sum":"bf151c7b356b294d9fd74166efe146a148d666fbc723db459ebecb56f1e503297bc08de8f6ae74c77dcb5dcf674dc8c4f9eca11219f9e54dc794cb9d6563643c"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_CQDA2_OCP_5p0_NCSIwPLDMoMCTP_80021BD1.HPb","HPE_E810_CQDA2_OCP_5p0_NCSIwPLDMoMCTP_80021BD1.xml","payload.json"],"Name":"HPE_E810_CQDA2_OCP_5p0_NCSIwPLDMoMCTP_80021BD1.fwpkg","SHA1Sum":"fb91851c5eda36659721c8fdbe738d93344d0fe2","SHA256Sum":"162e5e6459f3054192f84fb2f154fbfc9c09cc01b474a94c58249a47a902d191","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860006"],"TypeOfChange":"1","Version":"5.00"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_CQ2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_50c47f60cb1d4295b8394942c2","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860006"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069726.exe","SHA1Sum":"7bea197f62d9237ad3698c56654b63ff50f8f820","SHA256Sum":"02d38376c18d1911600c94d899e1bf0e79e6235b53ad5c906374ca7f1fdcf315","SHA512Sum":"5fd4d0f9b25b60b0dbc302194225feddb27e103d32195d237b023836a27d2bb717e35f19b624096f36abc87c9666855ff9fd10caac60d99afde61ecaa15b14f3"}],"ComponentSizeInKB":589,"CompsigList":["cp069726.compsig"],"FileList":["cp069726.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"Name":"cp069726.exe","SHA1Sum":"7bea197f62d9237ad3698c56654b63ff50f8f820","SHA256Sum":"02d38376c18d1911600c94d899e1bf0e79e6235b53ad5c906374ca7f1fdcf315","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.2.0"}],"InstallationDependency":{},"Name":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\nechesasr.inf_amd64_4549a532e2f9c151"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_154a444b0711470cab8f62e39a","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","U46","U46","U47","U47","U50","I44","H08","H08","H10","A48","U39","U40","U50","H10","H10","U60","U61","U56","A43","A43","A42","A42","U64"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8a0371a425-HPDC-3.1.x86_64.rpm","SHA1Sum":"1743ea6b0661b9e243936f4bab2c016bec404da3","SHA256Sum":"5b6e7f65ec68723ca9bf31054ebc2e54ec01f5d1440f1991a826ad9d6efe92e4","SHA512Sum":"45a6411ae938e45d353bd0408e409c4ae227354be912486442ad3159c6f7090a40fde22d179164fa4192baff4877be53742fe7e20eb031e1103c4edac30d57e7"}],"ComponentSizeInKB":5733,"CompsigList":["firmware-hdd-8a0371a425-HPDC-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/CP068858.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/TAMG08scHPDC.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068858.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068858.scexe"],"Name":"firmware-hdd-8a0371a425-HPDC-3.1.x86_64.rpm","SHA1Sum":"1743ea6b0661b9e243936f4bab2c016bec404da3","SHA256Sum":"5b6e7f65ec68723ca9bf31054ebc2e54ec01f5d1440f1991a826ad9d6efe92e4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JWXKH Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_32c19a99dc72438aa00618642c","SupportedDevices":["4d2340a5-3042-3631-3030-304a57584b48"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-cf0b6cabe1_0HPD4-2.1_amd64.deb","SHA1Sum":"0680317ae8bd200dcd1b569e6c5285bd040495ee","SHA256Sum":"a3b05c193d9beb36d169677f60831cf3aa36a7c6533fcd4900cdf2d44205e32f","SHA512Sum":"2f508c268741753f7cd13656dd708465f9c401c57f51da1145db6477219e2712c8df988201833b1d79f616327582c50a31b2d999d58a39d3b243d9cb8f0e329f"}],"ComponentSizeInKB":4515,"CompsigList":["firmware-hdd-cf0b6cabe1_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/CP071784.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/SHPEEVANSSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071784.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071784.scexe"],"Name":"firmware-hdd-cf0b6cabe1_0HPD4-2.1_amd64.deb","SHA1Sum":"0680317ae8bd200dcd1b569e6c5285bd040495ee","SHA256Sum":"a3b05c193d9beb36d169677f60831cf3aa36a7c6533fcd4900cdf2d44205e32f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3b1777d993b140908654ed4a59","SupportedDevices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3631-3030-304a575a4845","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3231-3030-304a575a4842"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070519.zip","SHA1Sum":"8d1aba01c3ad5582fbd38c3480a2bcec49457805","SHA256Sum":"cafe16b17284c014dee5a36ba1cae4ebe900f870095eccd2c4bad09942ad6439","SHA512Sum":"cebda026ad80a7fa83fe0d95aa03a572a0fbcb8bc65efbe77f7a45bcc9504a99efe75ead6bebbf3ae3fc9ef40a6c95aa4658a8827c902c373bc3621112bedc53"}],"ComponentSizeInKB":701,"CompsigList":["cp070519.compsig"],"FileList":["/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip","/cp070519.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/index.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/vendor-index.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_91.5.5.86.0-1OEM.900.0.24755229.vib","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/qlnativefc--987473699257504115.xml","/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/MRVL-QLogic-FC_91.5.5.86.0-1OEM.900.0.24755229.xml"],"Name":"cp070519.zip","SHA1Sum":"8d1aba01c3ad5582fbd38c3480a2bcec49457805","SHA256Sum":"cafe16b17284c014dee5a36ba1cae4ebe900f870095eccd2c4bad09942ad6439","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2026.04.01","VibList":[{"Name":"qlnativefc","Version":"91.5.5.86.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE QLogic Fibre Channel driver component for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":380,"RebootRequired":"yes","SWKeys":[{"Name":"qlnativefc:91.5.5.86.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:91.5.5.86.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ce00fbd4b013426f98c16e3080","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071619.exe","SHA1Sum":"91fb7fc4480afb83a951d77c85bfaff973002d03","SHA256Sum":"f4c7cacec059c99c4d4009aed23437835a06a16dbbdfc53e7d7440b4beb6f5a2","SHA512Sum":"961f29aef61f398cf7976c5b8d57cae19a620543ee801fa23dbfb0cb63e31dd9163411118fd33f3c47d7e2f3b74657097766b2403f396d5e8e915e201dbb0e4e"}],"ComponentSizeInKB":895,"CompsigList":["cp071619.compsig"],"FileList":["cp071619.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","megasas35.cat","MegaSas35.inf","MegaSas35.pdb","MegaSas35.RttMeta","MegaSas35.sys","nodev.inf"],"Name":"cp071619.exe","SHA1Sum":"91fb7fc4480afb83a951d77c85bfaff973002d03","SHA256Sum":"f4c7cacec059c99c4d4009aed23437835a06a16dbbdfc53e7d7440b4beb6f5a2","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec63a924ea"],"TypeOfChange":"1","Version":"7.738.8.0"}],"InstallationDependency":{},"Name":"MR416i-p, MR416i-a, MR216i-p, MR216i-a Gen10p Controllers and MR416i-o, MR416i-p, MR216i-o, MR216i-p, MR408i-o , MR408i-p Gen11 Controllers driver for Microsoft Windows 2022 edition","PackageFormat":"","PerDeviceInstallTimeSeconds":400,"RebootRequired":"yes","SWKeys":[{"Name":"MegaSas35.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_21a9dd1addbc499dabcf4dce54","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-mellanox-eth-only-mft-1.0.10-1.1.x86_64.rpm","SHA1Sum":"bf1d4027be16ccf32ae485866cdffb2764e7d4ea","SHA256Sum":"e67a5f1464f1387c42c579cb1abbeb34947c10405fe286ad741436a2deea323f","SHA512Sum":"41d912623d3a23a7a2da3759ad314335179d8c5dc4db2cf50a722790baa267534e1ed7faa1cad3347b53fb537c2374367734ea3c7a44853111f5cd54601d5ae6"}],"ComponentSizeInKB":3289,"CompsigList":["firmware-nic-mellanox-eth-only-mft-1.0.10-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/CP072378.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-eth-only-mft-1.0.10-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072378.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072378.scexe"],"Name":"firmware-nic-mellanox-eth-only-mft-1.0.10-1.1.x86_64.rpm","SHA1Sum":"bf1d4027be16ccf32ae485866cdffb2764e7d4ea","SHA256Sum":"e67a5f1464f1387c42c579cb1abbeb34947c10405fe286ad741436a2deea323f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.10"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fbf1b708f83c4ea7a20f0bf507","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["6.0","7.0","8.0","11.0","12.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","U32","A43","A43","A43","A47","A48","U40","U50","U47","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","U61","U37","A42","U56"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"12dda8adb3ce8996e5c68af5660a4b792a6d10d0","SHA256Sum":"6071be4257c3f9a77b0ee523bdfde0e97a54bcfc368d30454ba4bf6ff3e24ad7","SHA512Sum":"e01b3af4edfbe504c5a8955b2c2ddd007507e2ac8132a3b145db4d33d4e0be96a82e37eb562cd20e9b41da5b32529e2cd72ec1a8615b1d6f5c5c3a71c099d35a"}],"ComponentSizeInKB":4811,"CompsigList":["qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/6.4.0-150700.51-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"Name":"qlgc-qla2xxx-kmp-default-10.02.15.00_k1_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"12dda8adb3ce8996e5c68af5660a4b792a6d10d0","SHA256Sum":"6071be4257c3f9a77b0ee523bdfde0e97a54bcfc368d30454ba4bf6ff3e24ad7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.15.00-k1"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3829a63eceed47e4a618463a0a","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-6fc985bd3b-GPK8-4.1.x86_64.rpm","SHA1Sum":"4e3b9f5caa71ece323a7e4874769839b6158dc6d","SHA256Sum":"e4e70ee788f00bcedbf62137e058ca311fe3ea58aa47907359a927ca10ae76de","SHA512Sum":"f6b2c27093fa18eceefb1fb89b7e7a9103b0cc7eb587cd3bcde358b6d73aa09c7aa92e28518a2a1c501ae9f85c7cd98799df314b342841e51ea18be24230dad6"}],"ComponentSizeInKB":6147,"CompsigList":["firmware-hdd-6fc985bd3b-GPK8-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/CP068920.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/KACD6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6fc985bd3b-GPK8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068920.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068920.scexe"],"Name":"firmware-hdd-6fc985bd3b-GPK8-4.1.x86_64.rpm","SHA1Sum":"4e3b9f5caa71ece323a7e4874769839b6158dc6d","SHA256Sum":"e4e70ee788f00bcedbf62137e058ca311fe3ea58aa47907359a927ca10ae76de","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b5a913647d7640cd9a84628e9c","SupportedDevices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c31355433"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"cp068770.exe","SHA1Sum":"92f52c9381b9436b2fd927590fc06d003dcbfd06","SHA256Sum":"cfc1cb5428ff669cb4b07da4083dd5f626452f761dc995d7f1300595684fee38","SHA512Sum":"764d1517488c63111d8f3d850790c6ee2ccd9898a2590fc06f5a9b138ca2ca94cc9cd9e48c53ddf4093114532998e56d05d4e85e5dd07b440c98e13ed4be1978"}],"ComponentSizeInKB":3902,"CompsigList":["cp068770.compsig"],"FileList":["cp068770.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG08acHPG5.REL"],"Name":"cp068770.exe","SHA1Sum":"92f52c9381b9436b2fd927590fc06d003dcbfd06","SHA256Sum":"cfc1cb5428ff669cb4b07da4083dd5f626452f761dc995d7f1300595684fee38","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB016000GWXKK Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1bb16f5a976f41e0bd3d2e4fe9","SupportedDevices":["4d2340a5-3042-3631-3030-304757584b4b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b58565948","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58565a44","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58565a45","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b58565946","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b58565a41","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b58565a42","Version":"HPK4"},{"DeviceName":"Kioxia-CM7-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CM7_KACM7ALSHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3531-3336-304b58565a43","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_CM7_KACM7ALSHPK4.fwpkg","SHA1Sum":"a1992396bc7f3ca5335b7c4d42d1b4a539a7d68f","SHA256Sum":"f6e47615b74a8caa93eb06f71dbbcc31855fca777bb2113b3bb95f91ffc03110","SHA512Sum":"bad5e96610ac11070414253f053ae95bc89cff25424ac490307c9c456a07e7c1981b1176b0d2adaa2ccd0c2d33fd7780fa66cb18c11c9b877f32f8b3c93aebf1"}],"ComponentSizeInKB":2331,"CompsigList":[],"FileList":["Kioxia_CM7_KACM7ALSHPK4.HPb","Kioxia_CM7_KACM7ALSHPK4.xml","payload.json"],"Name":"Kioxia_CM7_KACM7ALSHPK4.fwpkg","SHA1Sum":"a1992396bc7f3ca5335b7c4d42d1b4a539a7d68f","SHA256Sum":"f6e47615b74a8caa93eb06f71dbbcc31855fca777bb2113b3bb95f91ffc03110","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-304b58565948","4d2340a5-304f-3330-3230-304b58565a44","4d2340a5-304f-3630-3430-304b58565a45","562340a5-304f-3130-3932-304b58565946","562340a5-304f-3330-3834-304b58565a41","562340a5-304f-3730-3638-304b58565a42","562340a5-304f-3531-3336-304b58565a43"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600KXVYH, MO003200KXVZD, MO006400KXVZE, VO001920KXVYF, VO003840KXVZA, VO007680KXVZB and VO015360KXVZC","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600KXVYH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXVZD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXVZE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXVYF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXVZA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXVZB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KXVZC","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5c536fa4fdef41e08d38b08ff1","SupportedDevices":["4d2340a5-304f-3130-3630-304b58565948","4d2340a5-304f-3330-3230-304b58565a44","4d2340a5-304f-3630-3430-304b58565a45","562340a5-304f-3130-3932-304b58565946","562340a5-304f-3330-3834-304b58565a41","562340a5-304f-3730-3638-304b58565a42","562340a5-304f-3531-3336-304b58565a43"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL6CBA0HPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a886842a99_0HPD4-2.1_amd64.deb","SHA1Sum":"a737ddde4d26fd5d53bf0598f3a21923c18d8ccc","SHA256Sum":"d46b9ac2ec6442e5a7e21135eff6119bbf178c0a1356668985f1597bb401e15d","SHA512Sum":"5082d888dda01bedb325b1671ec539c75b7e4be4260d61d61f3e2fc7f9292ad24a16728a13144da66af8e7b2cc9dc0b7eabe6b9236844f2c4c3cc28976749896"}],"ComponentSizeInKB":4672,"CompsigList":["firmware-hdd-a886842a99_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/CP073202.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/WVL6CBA0HPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073202.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073202.scexe"],"Name":"firmware-hdd-a886842a99_0HPD4-2.1_amd64.deb","SHA1Sum":"a737ddde4d26fd5d53bf0598f3a21923c18d8ccc","SHA256Sum":"d46b9ac2ec6442e5a7e21135eff6119bbf178c0a1356668985f1597bb401e15d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000JWKGN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_64e68e72e86146af9f97185388","SupportedDevices":["4d2340a5-3042-3630-3030-304a574b474e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U43_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u43-3.76_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"108e46a8d61ac7818cf07ecc1b718847ba816637","SHA256Sum":"7000699fc2b5e792004931da7451a2199614f92701df3df7730d489f2c26371d","SHA512Sum":"37a9fed6899f439985e28653cd623464865a7080bed6bb6d34c51e97f8c9c0d87cbf7f3a51ce8b2d9562b36fbafaf1b82f5b888ee54447e9da782d947bdcd6b1"}],"ComponentSizeInKB":8728,"CompsigList":["firmware-system-u43-3.76_2026_05_28-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/CP072030.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/U43_3.76_05_28_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u43-3.76_2026_05_28-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072030.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072030.scexe"],"Name":"firmware-system-u43-3.76_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"108e46a8d61ac7818cf07ecc1b718847ba816637","SHA256Sum":"7000699fc2b5e792004931da7451a2199614f92701df3df7730d489f2c26371d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL20 Gen10 (U43) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a572ec5bb5af4115a450a56483","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","15.0","12.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U60_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.70 (08/20/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073272.exe","SHA1Sum":"1a83462e5c130a6218a7594c117f200d5476c3f2","SHA256Sum":"79a856a1ad6fbdec40eb24c0e9e92584912f048b38648402d48352002025dff3","SHA512Sum":"c20ff5d03fe329ac822463393b4f1b230ef0daee33fe913afdccc9d86ad289d97e99804cecc3d6789d48eff6c69e341badbf181d356e387aca1b5d967c2bcf9a"}],"ComponentSizeInKB":17045,"CompsigList":["cp073272.compsig"],"FileList":["cp073272.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U60_2.70_08_20_2026.signed.flash"],"Name":"cp073272.exe","SHA1Sum":"1a83462e5c130a6218a7594c117f200d5476c3f2","SHA256Sum":"79a856a1ad6fbdec40eb24c0e9e92584912f048b38648402d48352002025dff3","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.70_08-20-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL20 Gen10 Plus Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e3286b867f4a44179a752609c1","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-18e328f036_0HPG8-2.1_amd64.deb","SHA1Sum":"859ea9b57bb26fbf7bd0c7612223110de0be7638","SHA256Sum":"6cc4322155f54d18d0aa885ce189ffc6b16170b5e337bb1cc3c71194304f208c","SHA512Sum":"3f4be5d4dab6901b3f84539083665c87f6c39ea992fe308ee003ca20559eb1e247344d14999909e2bca1bf92118d6e6b04ff8b6a4aac119e016c0d4e5d252f4c"}],"ComponentSizeInKB":4222,"CompsigList":["firmware-hdd-18e328f036_0HPG8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/CP071731.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/SCIMARRNETG8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071731.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-18e328f036-HPG8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071731.scexe"],"Name":"firmware-hdd-18e328f036_0HPG8-2.1_amd64.deb","SHA1Sum":"859ea9b57bb26fbf7bd0c7612223110de0be7638","SHA256Sum":"6cc4322155f54d18d0aa885ce189ffc6b16170b5e337bb1cc3c71194304f208c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000GWWQU and MB006000GWWQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_18bd953b7d614725834386e84b","SupportedDevices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"amsd-5.1.0-2197.8.rhel10.x86_64.rpm","SHA1Sum":"c8bdafa680e90b06802a9109a9430a9a2367bfd6","SHA256Sum":"248e9f03cfde476831a20e764ed5c9f430a32c98682b5f73615e88d2af3ed0a7","SHA512Sum":"13b09aff29cf73333220cb635c003d8c3a87b00297ca711000f62deef7813c3be00504121f23211438b2bffbdb20975fe2e8d2354ac03d840cee03badcb3471b"}],"ComponentSizeInKB":11698,"CompsigList":["amsd-5.1.0-2197.8.rhel10.x86_64.compsig"],"FileList":["./etc/sysconfig/ahslog","./etc/sysconfig/amsd","./etc/sysconfig/amsd_rev","./etc/sysconfig/cpqFca","./etc/sysconfig/cpqFca_rev","./etc/sysconfig/cpqIde","./etc/sysconfig/cpqIde_rev","./etc/sysconfig/cpqScsi","./etc/sysconfig/cpqScsi_rev","./etc/sysconfig/cpqiScsi","./etc/sysconfig/mr_cpqScsi","./etc/sysconfig/mr_cpqScsi_rev","./etc/sysconfig/smad","./etc/sysconfig/smad_rev","./opt/amsd","./opt/amsd/amsd.license","./sbin/ahslog","./sbin/amscli","./sbin/cpqiScsi","./usr/lib/.build-id","./usr/lib/.build-id/0b","./usr/lib/.build-id/0b/0d7a6906b056bd4a56de172db3579041d1c4ea","./usr/lib/.build-id/0b/0d7a6906b056bd4a56de172db3579041d1c4ea.1","./usr/lib/.build-id/59","./usr/lib/.build-id/59/923023b45852957d8dfed3aaf5008524ed223e","./usr/lib/.build-id/59/923023b45852957d8dfed3aaf5008524ed223e.1","./usr/lib/.build-id/71","./usr/lib/.build-id/71/c93b3aabb92c83b21239ac65f501af7db5a634","./usr/lib/.build-id/75","./usr/lib/.build-id/75/5ec3e6b3009df57c6dc166209a47912f601112","./usr/lib/.build-id/86","./usr/lib/.build-id/86/4eef18b4bce47a4cf28b57b5a16c2c0e8f626d","./usr/lib/.build-id/86/4eef18b4bce47a4cf28b57b5a16c2c0e8f626d.1","./usr/lib/.build-id/9f","./usr/lib/.build-id/9f/42e7d3e2bd7c04ef483a1c90f5e5f215f7be73","./usr/lib/.build-id/9f/42e7d3e2bd7c04ef483a1c90f5e5f215f7be73.1","./usr/lib/.build-id/cb","./usr/lib/.build-id/cb/b40781e383a6f036155697b909edc2526d47d9","./usr/lib/.build-id/cb/b40781e383a6f036155697b909edc2526d47d9.1","./usr/lib/.build-id/fd","./usr/lib/.build-id/fd/432790f6231df705632b82b47db627c979bb3e","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/c89126471bf249ecf9dfbcaddb0841008ae4cb","./usr/lib/.build-id/fe/c89126471bf249ecf9dfbcaddb0841008ae4cb.1","./usr/lib/systemd/system/ahslog.service","./usr/lib/systemd/system/amsd.service","./usr/lib/systemd/system/amsd_rev.service","./usr/lib/systemd/system/cpqFca.service","./usr/lib/systemd/system/cpqFca_rev.service","./usr/lib/systemd/system/cpqIde.service","./usr/lib/systemd/system/cpqIde_rev.service","./usr/lib/systemd/system/cpqScsi.service","./usr/lib/systemd/system/cpqScsi_rev.service","./usr/lib/systemd/system/cpqiScsi.service","./usr/lib/systemd/system/mr_cpqScsi.service","./usr/lib/systemd/system/mr_cpqScsi_rev.service","./usr/lib/systemd/system/smad.service","./usr/lib/systemd/system/smad_rev.service","./usr/lib/udev/rules.d/81-cpqFca.rules","./usr/lib/udev/rules.d/81-cpqiScsi.rules","./usr/share/man/man8/ahslog.8.gz","./usr/share/man/man8/amsd.8.gz","./usr/share/man/man8/cpqFca.8.gz","./usr/share/man/man8/cpqIde.8.gz","./usr/share/man/man8/cpqScsi.8.gz","./usr/share/man/man8/cpqiScsi.8.gz","./usr/share/man/man8/mr_cpqScsi.8.gz","./usr/share/man/man8/smad.8.gz","./usr/share/smartupdate/amsd/component.xml","./sbin/amsd","./sbin/amsd_rev","./sbin/cpqFca","./sbin/cpqFca_rev","./sbin/cpqIde","./sbin/cpqIde_rev","./sbin/cpqScsi","./sbin/cpqScsi_rev","./sbin/mr_cpqScsi","./sbin/mr_cpqScsi_rev","./sbin/smad","./sbin/smad_rev"],"Name":"amsd-5.1.0-2197.8.rhel10.x86_64.rpm","SHA1Sum":"c8bdafa680e90b06802a9109a9430a9a2367bfd6","SHA256Sum":"248e9f03cfde476831a20e764ed5c9f430a32c98682b5f73615e88d2af3ed0a7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb37bf5ae"],"TypeOfChange":"1","Version":"5.1.0"}],"InstallationDependency":{},"Name":"Agentless Management Service (iLO 5 and above) for Red Hat Enterprise Linux 10 Server","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"amsd","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8d2f7f926b6b48a4a5fa35568b","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-103c-330615903307","a6b1a447-382a-5a4f-103c-330715903307","a6b1a447-382a-5a4f-103c-3307159004bd","a6b1a447-382a-5a4f-103c-3306159004bd"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U43","U41","U33","U44","A47","A48","U40","U47","U45","U24","U37","A46","U47","U38","U38","A45","U50","U46","I43","I45","I44","I42","A42","U54","U54","U54","U61","U60","U58","U58","U63","U63","A55","A55","A56","A56","U59","U64","U58","U62","U57","U65","U65","A58","U69","U69","H11","U71","U72","U68","U68","U68","U66","U71","U68","I46","U72","U70","A59","U73","A66","A66","U74","U77","U71","U77","U83","A72"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.70 (08/19/2026)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073132.exe","SHA1Sum":"d1cf2b2aebb7598a9497a749292b6b152b769e5f","SHA256Sum":"18be8bdfb87de1e11b2a12769d84c5ce423e0f592daea231b9e6dd5c1b0f77e7","SHA512Sum":"a1fa1e0a8b087e7f01458c4c0dd41b92f0adcc7c4af45d479e512902a43c709d99ea3fc792f3adf66de0e708cdfbe7fdb13c464d2c00cd89db6a73ffbcd93860"}],"ComponentSizeInKB":11235,"CompsigList":["cp073132.compsig"],"FileList":["cp073132.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U31_3.70_08_19_2026.signed.flash"],"Name":"cp073132.exe","SHA1Sum":"d1cf2b2aebb7598a9497a749292b6b152b769e5f","SHA256Sum":"18be8bdfb87de1e11b2a12769d84c5ce423e0f592daea231b9e6dd5c1b0f77e7","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fbd3a001d8b5465a9a7b138ba9","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U31","U31"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071254.exe","SHA1Sum":"cc6c717cd49042a5569b741613227a2eff08ee6a","SHA256Sum":"424c11a39e26d576d0370a55ea556617f39ac0821e53183ef294574002a938a9","SHA512Sum":"4352d412e16664d3e9c895877b387b931c17953d57cb1e67c1d664c652d11fe98161dcdba0571df65afd9953348cf2ef8fe2621da411b4d6e0271cfd4c8fe621"}],"ComponentSizeInKB":1719,"CompsigList":["cp071254.compsig"],"FileList":["cp071254.xml","cpqsetup.exe","install.xml","ql2300.cat","ql2300.sys","ql2x00.inf","QLOGIC","qlsrvc.exe","QlStorInstaller.dll","readme.txt","release.txt","SysConfig.frm","SysConfig.frm.ja","txtsetup.oem"],"Name":"cp071254.exe","SHA1Sum":"cc6c717cd49042a5569b741613227a2eff08ee6a","SHA256Sum":"424c11a39e26d576d0370a55ea556617f39ac0821e53183ef294574002a938a9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfcb30565"],"TypeOfChange":"1","Version":"9.4.11.20"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 QLogic Storport Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"ql2300.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_127103a853ce4c17a64765cb78","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398"]},{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072316.zip","SHA1Sum":"1e18153ebe666402fe21a220861d73e56cbf59c4","SHA256Sum":"2bbdcf189f83c0da685be92ee00e4c26669ada8a2df0a0e8a355aa47ca21acd1","SHA512Sum":"f1a1862eaf42dfee9cecd05d0d57fb6ff52bd08aa4a57541a65f99b3747fbc9e6981571b242bef27afd2a78f0faecf254ae1e694a5a90d82cad8a7bb01965b65"}],"ComponentSizeInKB":912,"CompsigList":["cp072316.compsig"],"FileList":["/cp072316.xml","/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.zip","/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.zip/index.xml","/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.zip/vib20/icen/INT_bootbank_icen_2.6.5.0-1OEM.800.1.0.20613240.vib","/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/icen-3138655778806053384.xml","/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Intel-icen_2.6.5.0-1OEM.800.1.0.20613240.xml"],"Name":"cp072316.zip","SHA1Sum":"1e18153ebe666402fe21a220861d73e56cbf59c4","SHA256Sum":"2bbdcf189f83c0da685be92ee00e4c26669ada8a2df0a0e8a355aa47ca21acd1","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"icen","Version":"2.6.5.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"Intel icen Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-icen:2.6.5.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:2.6.5.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_17317945e19f4f0eb85825be72","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-124a80860001","a6b1a447-382a-5a4f-8086-124a80860008","a6b1a447-382a-5a4f-8086-124a80860004","a6b1a447-382a-5a4f-8086-124a80860002","a6b1a447-382a-5a4f-8086-124980860002","a6b1a447-382a-5a4f-8086-124980860005"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H08","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U47","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssaducli-6.65-9.0.x86_64.rpm","SHA1Sum":"4156d8be76e28e7cf4713c882bf4595dfd8c8b85","SHA256Sum":"328bcff7be9369cf60f8c6776f468ee8e677a0dfb08681731d4f008ea30c496a","SHA512Sum":"879883eafc01705e143dcd1107298df370b88f5d002dab47edf0d99c8c6f87080137966745f381a2388de837804ea64ee8c48b2658ff6e3c3a98916c214bd016"}],"ComponentSizeInKB":3586,"CompsigList":["ssaducli-6.65-9.0.x86_64.compsig"],"FileList":["./opt/smartstorageadmin/ssaducli","./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/man/man8/ssaducli.8.gz","./usr/sbin/ssaducli","./usr/share/smartupdate/ssaducli/component.xml"],"Name":"ssaducli-6.65-9.0.x86_64.rpm","SHA1Sum":"4156d8be76e28e7cf4713c882bf4595dfd8c8b85","SHA256Sum":"328bcff7be9369cf60f8c6776f468ee8e677a0dfb08681731d4f008ea30c496a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssaducli","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c5049f2c88a84b789bbbbc8650","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A47","A48","U47","A46","U47","I44","U63","I45","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","U14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","Carbondale14","U19","Carbondale14","Carbondale14","I40","I37","I39","I40","U57","U65","U62","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"cp068647.exe","SHA1Sum":"14b5d32bc1127aeb7f9659270d0b02083e073c43","SHA256Sum":"c8783d5e235cd847f1aa33655a68ce15b2f833ce6d1e476e32a2013e28a6d070","SHA512Sum":"63a9b42a95c9f5a692b6b6ba9bea929d9c134df7bc923f0e390d7dc9778bf9ca9b6b4197a93ef03a15f3c0691a4f1c1173d80ee7f4a7381183f8360011fb01fc"}],"ComponentSizeInKB":3650,"CompsigList":["cp068647.compsig"],"FileList":["cp068647.xml","cpqsetup.exe","KARM5ALSHPD8.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068647.exe","SHA1Sum":"14b5d32bc1127aeb7f9659270d0b02083e073c43","SHA256Sum":"c8783d5e235cd847f1aa33655a68ce15b2f833ce6d1e476e32a2013e28a6d070","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f2fede41d4c74f11919547b30c","SupportedDevices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZ1LB960HAJQ-00007","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"EDA7602Q.bin","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"EDA7602Q"},{"DeviceName":"MZ1LB1T9HALS-00007","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"EDA7602Q.bin","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"EDA7602Q"}]},"Files":[{"Checksum":[{"Filename":"cp070450.exe","SHA1Sum":"d696ce86946a31e2d11a9e3f37be97722fa67079","SHA256Sum":"132377578ac6296559d4826dd661535538a15e26120020311eb0a2c20e33c9ba","SHA512Sum":"99628d684a4344016e3ff51386ba19e8cf33ea991969106c6dbde88b1878bddbaa481c1ce3df3f57a20e6d0866e79f0eab27c3573a086d2a0bb7155ab7424ac2"}],"ComponentSizeInKB":7022,"CompsigList":["cp070450.compsig"],"FileList":["cp070450.xml","cpqsetup.exe","EDA7602Q.bin","ilorest_chif.dll","payload.json"],"Name":"cp070450.exe","SHA1Sum":"d696ce86946a31e2d11a9e3f37be97722fa67079","SHA256Sum":"132377578ac6296559d4826dd661535538a15e26120020311eb0a2c20e33c9ba","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"EDA7602Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Microsoft Windows - MZ1LB960HAJQ-00007, MZ1LB1T9HALS-00007 and MZ1LB3T8HMLA-00007 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MZ1LB960HAJQ-00007","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZ1LB1T9HALS-00007","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8bb509c565c0443b889276758c","SupportedDevices":["4d2340a5-315a-424c-3154-3948c2e5811f","4d2340a5-315a-424c-3936-304820becacc","4d2340a5-315a-424c-3354-384894df255d"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["11.0","10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H09","H10","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U47_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U47_2.70_08_19_2026.fwpkg","SHA1Sum":"f0091e23fca290910b441bf50620b388ca6c4198","SHA256Sum":"5f37eebf84fe326a205b8e080b406e1fc77cd18f96456f53968b42ed4b36be5d","SHA512Sum":"7615533ccc661e2a76803925e9af80b8bf2d6902fd6ff5c5a497e82635efbcc3e40469afd137c39ed1a5912d2cd9ff6029fe202fd0283fbf2f1f5435bf9fd3b6"}],"ComponentSizeInKB":32817,"CompsigList":[],"FileList":["payload.json","U47_2.70_08_19_2026.signed.flash","U47_2.70_08_19_2026.xml"],"Name":"U47_2.70_08_19_2026.fwpkg","SHA1Sum":"f0091e23fca290910b441bf50620b388ca6c4198","SHA256Sum":"5f37eebf84fe326a205b8e080b406e1fc77cd18f96456f53968b42ed4b36be5d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47)","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_74a11012fc0a40c780d1ed0cfb","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U47","U47"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-020fc874ad_0HPD3-2.1_amd64.deb","SHA1Sum":"3d8669f8bf7eb71a5998c05c4709831027c74ea9","SHA256Sum":"d756556c961dcb2041c9592dd3c46e13c0d83e47aec0f149c90ab5ecba16c5dd","SHA512Sum":"99baee857886f8d1e6ac3d05cb1bd5449e68ac8bc33a68fe16e4787ab78e2cfb0f1652df07ca5f8dc222a5d24189ff2e563b7807242240e7656bb9fcde89ced6"}],"ComponentSizeInKB":4509,"CompsigList":["firmware-hdd-020fc874ad_0HPD3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/CP071801.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/SLONGSPKESD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071801.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071801.scexe"],"Name":"firmware-hdd-020fc874ad_0HPD3-2.1_amd64.deb","SHA1Sum":"3d8669f8bf7eb71a5998c05c4709831027c74ea9","SHA256Sum":"d756556c961dcb2041c9592dd3c46e13c0d83e47aec0f149c90ab5ecba16c5dd","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - MB018000JXMTH and MB020000JXMTP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7183100acd934e559d8a2b05c5","SupportedDevices":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071589.exe","SHA1Sum":"3769074f2537137af88ef70529e66336ee348d6d","SHA256Sum":"ba831c4fd9c2c6d0bb840b521718f4a6d8525151ef40e099eb50796fff788d00","SHA512Sum":"b6879a7f362d7d9823e3169883e0ee7bf1ca08f7aff6e10853f7bda098515d6f4a2b756f3aa738a8d9f2c099013cf729c6f0ecd37fcaaf86ed99eee200e9e657"}],"ComponentSizeInKB":958,"CompsigList":["cp071589.compsig"],"FileList":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp071589.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp071589.exe","SHA1Sum":"3769074f2537137af88ef70529e66336ee348d6d","SHA256Sum":"ba831c4fd9c2c6d0bb840b521718f4a6d8525151ef40e099eb50796fff788d00","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"TypeOfChange":"1","Version":"221.0.10.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NX1 1Gb Driver for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"b57nd60a.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a7d1b02525a54541b5c62e7367","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U37","U38","U38","O43","U40","U39","02020001","03020101","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","A59","U66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070843.zip","SHA1Sum":"043932c26c7d96accc31e39b8d17549ca639a9c9","SHA256Sum":"1f7ed0cd4fadad9adef2273e2d0737af00c3774272c505365208cdb3c2f98ec2","SHA512Sum":"0cc65d6cdaaabca2c2f3b5830db9184b08efbadfa8c966f8ddf7dfd8736ab455d81a9131e55e65a3814c476b8553069b7ad32e4ee9e820b38679a27d099b39f2"}],"ComponentSizeInKB":1486,"CompsigList":["cp070843.compsig"],"FileList":["/cp070843.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"Name":"cp070843.zip","SHA1Sum":"043932c26c7d96accc31e39b8d17549ca639a9c9","SHA256Sum":"1f7ed0cd4fadad9adef2273e2d0737af00c3774272c505365208cdb3c2f98ec2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7c18c1bccaff4d8ca61e5a5c02","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u8.x86_64.rpm","SHA1Sum":"e477525f87f850f9d7408f5d65b83ed0c8ea63b8","SHA256Sum":"29aa84069e354cf138498c1e84ef0c7d94d4e0f542538f4a14c9515c17163a2c","SHA512Sum":"e64a2b56ad02cd3d016c90eb290c744f1c801f175ca37cdede44334f85d2cac958773897ab3e3939499ebf5ba87584a5b3dc764b8bb5a6a74119e3e096a4bc0a"}],"ComponentSizeInKB":1404,"CompsigList":["kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"Name":"kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u8.x86_64.rpm","SHA1Sum":"e477525f87f850f9d7408f5d65b83ed0c8ea63b8","SHA256Sum":"29aa84069e354cf138498c1e84ef0c7d94d4e0f542538f4a14c9515c17163a2c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-238.1.165.0"},{"Checksum":[{"Filename":"kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u7.x86_64.rpm","SHA1Sum":"5cc0d07ce596e33eaaa00dea270face441dfff91","SHA256Sum":"59939cb0c8d912b9c7cf0b9fadfd99e2eca35c89986a76d15a0ba90590705287","SHA512Sum":"cc85a2aca65b3b04ad4d57912badbc8d7f98dbad149a77f13498e819e220f78a2c49ef43106470c300711516cfdca83a5c31e03f0c7a30fd777b2edb808ee2ea"}],"ComponentSizeInKB":1427,"CompsigList":["kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"Name":"kmod-bnxt_en-1.10.3-238.1.165.0.rhel9u7.x86_64.rpm","SHA1Sum":"5cc0d07ce596e33eaaa00dea270face441dfff91","SHA256Sum":"59939cb0c8d912b9c7cf0b9fadfd99e2eca35c89986a76d15a0ba90590705287","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3bbecc404a204fa0b0a460d366","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVLACBA0HPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp073157.exe","SHA1Sum":"663878b838ff9d54d36ca4844280089b217a1087","SHA256Sum":"a3f61229a86f566c2c6144c765cf7dce7d7310da3f63df502198499e30b9d887","SHA512Sum":"c4d330fcf0d284453b3103c16cdf81d3e14f687bf7bc944a2ccc1025d74b2bed7a86e40df79b09fb881504961e355c3bdcf09e8bc0eb35647521cf4a9ee610df"}],"ComponentSizeInKB":4447,"CompsigList":["cp073157.compsig"],"FileList":["cp073157.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WVLACBA0HPD4.rel"],"Name":"cp073157.exe","SHA1Sum":"663878b838ff9d54d36ca4844280089b217a1087","SHA256Sum":"a3f61229a86f566c2c6144c765cf7dce7d7310da3f63df502198499e30b9d887","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000JWKGU Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b2b7e69d0afa4b3aba39eaa14e","SupportedDevices":["4d2340a5-3042-3430-3030-304a574b4755"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ixgbevf-kmp-default-5.3.36_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"dd6d90e60552b3e68fece71b998f8158645e370e","SHA256Sum":"f58d0354b947ba767160ea680f0670d6a46eadd52f563531c84179f8138556b8","SHA512Sum":"c7ad8b3b42d995b993d63753b8745587389f69e5e9bd97034fca2e459abc32abc279cfd5d552821cc4f2e6f39ff189cf84131a0e3469537d648988878d9751fa"}],"ComponentSizeInKB":106,"CompsigList":["ixgbevf-kmp-default-5.3.36_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/ixgbevf.ko","./usr/share/doc/packages/ixgbevf-kmp-default","./usr/share/doc/packages/ixgbevf-kmp-default/COPYING","./usr/share/doc/packages/ixgbevf-kmp-default/README","./usr/share/man/man7/ixgbevf.7.gz","./usr/share/pci.ids.d/pci.ids.ixgbevf-kmp-5.3.36","./usr/share/smartupdate/ixgbevf-kmp-default/component.xml"],"Name":"ixgbevf-kmp-default-5.3.36_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"dd6d90e60552b3e68fece71b998f8158645e370e","SHA256Sum":"f58d0354b947ba767160ea680f0670d6a46eadd52f563531c84179f8138556b8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0183d0f4"],"TypeOfChange":"1","Version":"5.3.36-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3026c56f695140fb80f8650cf8","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"cp072360.exe","SHA1Sum":"15b4772a01ff6d9dfecfa3de400f30dfaf09eaf5","SHA256Sum":"37425bc92e97599670bc2b64c5dd98a948528da9488fa999bef581e016e8b704","SHA512Sum":"f6aa30516945a891ed19f84e5351235c4d42f17bd3a8fa6c0f511aa8d64efbf5890d797ba19b28341ff997de9a537bc1a9f51978d497c1c7dc8ac6f969bf7e26"}],"ComponentSizeInKB":26861,"CompsigList":["cp072360.compsig"],"FileList":["cp072360.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072360.exe","SHA1Sum":"15b4772a01ff6d9dfecfa3de400f30dfaf09eaf5","SHA256Sum":"37425bc92e97599670bc2b64c5dd98a948528da9488fa999bef581e016e8b704","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.0.25"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox Ethernet only adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_479ac3db85f34b889bce665537","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.2","6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","P89","U32","P89","U36","U22","U41","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U39","U19","U56","U61","U45","U25","U37","HPE ProLiant SL4500 Chassis","U39","HPE Apollo 6500 Gen10 System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.23"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.23"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.23"}]},"Files":[{"Checksum":[{"Filename":"CP071763.zip","SHA1Sum":"d7d525f9fa1803a1b7b9856e3199e3ea27141806","SHA256Sum":"6aa5bfbcad67e10213e953a453bb0d0b7d9bdc9802620b2c3bcba6bb02d6df0b","SHA512Sum":"4cfdd95f9af9af18fd55db2966378258ad7aa3ac26f34eea7e69a7dd4a57e9ea1c50227a022b53041f3a6ce604045d444f11019e705e0d30f3234409074cfad5"}],"ComponentSizeInKB":24992,"CompsigList":["CP071763.compsig"],"FileList":["/CP071763_BUILD_1.data","/CP071763.vmexe64","/CP071763.vmfile","/CP071763_VMw.zip","/CP071763.xml","/payload.json","/CP071763_VMw.zip/index.xml","/CP071763_VMw.zip/vendor-index.xml","/CP071763_VMw.zip/metadata.zip","/CP071763_VMw.zip/vib20/CP071763/HPE_bootbank_CP071763_8.23.1-8.0.0.20613240.vib","/CP071763_VMw.zip/metadata.zip/vendor-index.xml","/CP071763_VMw.zip/metadata.zip/vmware.xml","/CP071763_VMw.zip/metadata.zip/vibs/CP071763-5125222314466472080.xml","/CP071763_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071763_8.23.1-8.0.0.20613240.xml"],"Name":"CP071763.zip","SHA1Sum":"d7d525f9fa1803a1b7b9856e3199e3ea27141806","SHA256Sum":"6aa5bfbcad67e10213e953a453bb0d0b7d9bdc9802620b2c3bcba6bb02d6df0b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.23","VibList":[{"Name":"CP071763","Version":"8.23.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_46e1db2d8433437d9b3010ccc1","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["A41","A40"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-tg3-3.140b-1.rhel9u8.x86_64.rpm","SHA1Sum":"9ea9509a2e6594a961cc73a64f34329ae2e2aad9","SHA256Sum":"1bdf1860dca011080cc76a2911c5a926b76955a3db469ddf8e5ff9e69fdc2c13","SHA512Sum":"ce5e70b3ea78c08f556034a4ef9a589aa5af54a252e82e8f8e0efd3b3e054d79f653ca35cb6cbee65bcc0959cb9afbbff4bf5caeaa6c70ec411c411c1cd2b132"}],"ComponentSizeInKB":160,"CompsigList":["kmod-tg3-3.140b-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/tg3.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/tg3","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/f4","./usr/lib/.build-id/f4/2ce2504eb948ce3f7f81db28d36dd059e8f653","./usr/share/smartupdate/kmod-tg3/component.xml"],"Name":"kmod-tg3-3.140b-1.rhel9u8.x86_64.rpm","SHA1Sum":"9ea9509a2e6594a961cc73a64f34329ae2e2aad9","SHA256Sum":"1bdf1860dca011080cc76a2911c5a926b76955a3db469ddf8e5ff9e69fdc2c13","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.140b-1"},{"Checksum":[{"Filename":"kmod-tg3-3.140b-1.rhel9u7.x86_64.rpm","SHA1Sum":"45c0510ea6f3977f6e9b8ca8c5b7189272a7d196","SHA256Sum":"b6395da4186a9ba366debe3b85d1b075ec8ece892774ad60045d850bb1c3e2bf","SHA512Sum":"1e3281085c286757732e7e926ea305eed75bff35451008a7d0bfaa74fbad7f07652f800c7de1e6f4a96bbc857b1c001791badafbf3afb3a52855e2f26c0a28a9"}],"ComponentSizeInKB":161,"CompsigList":["kmod-tg3-3.140b-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/tg3.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/tg3","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/d3","./usr/lib/.build-id/d3/f876496795b4aa1cdb05e5d14cfeb0bb1fbc75","./usr/share/smartupdate/kmod-tg3/component.xml"],"Name":"kmod-tg3-3.140b-1.rhel9u7.x86_64.rpm","SHA1Sum":"45c0510ea6f3977f6e9b8ca8c5b7189272a7d196","SHA256Sum":"b6395da4186a9ba366debe3b85d1b075ec8ece892774ad60045d850bb1c3e2bf","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.140b-1"}],"InstallationDependency":{},"Name":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_feb9a0fa256449f3974850859b","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","02020001","03020101","A42","U56","U61","U60","U58","U58","03030202","U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U39","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072196.exe","SHA1Sum":"68636e3a4e3eb762f03a7aeb21402d150a310672","SHA256Sum":"b2fbe0b233124652d05ae4be171c94ef3c8f9a4e9a26f5e4f46e02c867d38fb4","SHA512Sum":"aacee2222dd2767997bbdc6404d78656b7e445e6f631d224b518685cdda2883f496f2d4b99dd5dcc59ba2d54b82e4079bff3d2871608644ec7f158826934d830"}],"ComponentSizeInKB":2434,"CompsigList":["cp072196.compsig"],"FileList":["cp072196.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072196.exe","SHA1Sum":"68636e3a4e3eb762f03a7aeb21402d150a310672","SHA256Sum":"b2fbe0b233124652d05ae4be171c94ef3c8f9a4e9a26f5e4f46e02c867d38fb4","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_35cc99ba78f4424693990bb311","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159000d3","a6b1a447-382a-5a4f-15b3-1016159000d4","a6b1a447-382a-5a4f-15b3-101815900246"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","U34","U34","A40","U30","P89","U32","P89","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08ADAeG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3630-3030-3047575a564c","Version":"HPG3"},{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08ADAeG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3830-3030-3047575a564e","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"Toshiba_MG08Air_TAMG08ADAeG3.fwpkg","SHA1Sum":"f08231e60ff630527f7f35a652abbe1348965d21","SHA256Sum":"7eb28ad95d2e036e5141cd435f5162cc7a53e373089a2ea8c98253e010c5247e","SHA512Sum":"d73c1366eba27fab03a6f3631e2afaf9f70034f1f7c387ccd881efc5c049da84e3d78743ed1d275a9f8dc8b618f3ca6ff4fe077f974bc8de16fd9bf739831256"}],"ComponentSizeInKB":1252,"CompsigList":[],"FileList":["payload.json","Toshiba_MG08Air_TAMG08ADAeG3.HPb","Toshiba_MG08Air_TAMG08ADAeG3.xml"],"Name":"Toshiba_MG08Air_TAMG08ADAeG3.fwpkg","SHA1Sum":"f08231e60ff630527f7f35a652abbe1348965d21","SHA256Sum":"7eb28ad95d2e036e5141cd435f5162cc7a53e373089a2ea8c98253e010c5247e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047575a564c","4d2340a5-3042-3830-3030-3047575a564e"],"TypeOfChange":"2","Version":"HPG3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB006000GWZVL and MB008000GWZVN","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWZVL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB008000GWZVN","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_22b25cb7056247fca6f226ad38","SupportedDevices":["4d2340a5-3042-3630-3030-3047575a564c","4d2340a5-3042-3830-3030-3047575a564e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssa-6.65-9.0_amd64.deb","SHA1Sum":"11025e8cf7d4f1a23e64234fc0d4c3faef66663e","SHA256Sum":"0d62f86c317968940e3dd72f0fa7ec4e6f452692afcff406a99df65e6a2df43c","SHA512Sum":"834179f8d5b8ac562a8bc613d58b8be51d324064ef7d04375208806d8d2ec672ca8a159dbcfc3c176171066660ed0aec0b5ee03f6345df6ca927a26942fb347b"}],"ComponentSizeInKB":7416,"CompsigList":["ssa-6.65-9.0_amd64.compsig"],"FileList":["./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/sbin/ssa","./usr/share/doc/ssa/changelog.Debian.gz","./usr/share/doc/ssa/copyright","./usr/share/man/man8/ssa.8.gz","./usr/share/smartupdate/ssa/component.xml"],"Name":"ssa-6.65-9.0_amd64.deb","SHA1Sum":"11025e8cf7d4f1a23e64234fc0d4c3faef66663e","SHA256Sum":"0d62f86c317968940e3dd72f0fa7ec4e6f452692afcff406a99df65e6a2df43c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssa","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f380215792b04537b788d24d31","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","U63","I45","U58","U58","U58","U59","U54","U54","U63","U54","A56","A56","A55","A55","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U18","U18","U18","U21","U25","U27","U24","U13","U13","U12","U14","U14","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","Carbondale14","Carbondale14","U19","Carbondale14","I40","I37","I39","I40","U57","U65","U62","U65","U71","A66","U71","U68","U68","A66","U68","U72"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ice-kmp-default-2.6.6_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"aa989eec35868c8fb5731ad8b95c0ae06f6f8a8e","SHA256Sum":"dccf929098a79ea4612887b50a733506040ce855402e991b36ddcc4733617052","SHA512Sum":"399802f90f06381c4d01e09a049cc1ae5c3dff0ab18f9c7f82022eb84ec962fe1ae1c5b6e3bbd4c332435babe0e3b7e98cc28e47a9e611fcfa9825437a7e2913"}],"ComponentSizeInKB":1150,"CompsigList":["ice-kmp-default-2.6.6_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./usr/lib/modules/6.12.0-160000.5-default/updates/ice.ko","./usr/share/doc/packages/ice-kmp-default","./usr/share/doc/packages/ice-kmp-default/COPYING","./usr/share/doc/packages/ice-kmp-default/README","./usr/share/man/man7/ice.7.gz","./usr/share/pci.ids.d/pci.ids.ice-kmp-2.6.6","./usr/share/smartupdate/ice-kmp-default/component.xml"],"Name":"ice-kmp-default-2.6.6_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"aa989eec35868c8fb5731ad8b95c0ae06f6f8a8e","SHA256Sum":"dccf929098a79ea4612887b50a733506040ce855402e991b36ddcc4733617052","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20e3b114"],"TypeOfChange":"1","Version":"2.6.6-1"}],"InstallationDependency":{},"Name":"Intel ice Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ice-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d65b82bad0b54ab6883005c835","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-579e80860001","a6b1a447-382a-5a4f-8086-579E80860000","a6b1a447-382a-5a4f-8086-12d380860007","a6b1a447-382a-5a4f-8086-124a80860001","a6b1a447-382a-5a4f-8086-124a80860008","a6b1a447-382a-5a4f-8086-124a80860004","a6b1a447-382a-5a4f-8086-124a80860002","a6b1a447-382a-5a4f-8086-124980860002","a6b1a447-382a-5a4f-8086-124980860005"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d39e7a7e75_0HPG1-2.1_amd64.deb","SHA1Sum":"4ac856d35a43d3dcc4370ffb222b231a46e82444","SHA256Sum":"908372dac49325de0533112949507c0d17fb60466f2bd5c29c63fb50f7fdd8e0","SHA512Sum":"f7afd5ae13c76b80185ebed1fdf87ae3755613d394fc5428d54a4424aa8a23a18fb5e65e60074b1525eb0c18ca26218746743520da160c74a83784105cd2be48"}],"ComponentSizeInKB":4004,"CompsigList":["firmware-hdd-d39e7a7e75_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/CP071775.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/TATCATSATAG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071775.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071775.scexe"],"Name":"firmware-hdd-d39e7a7e75_0HPG1-2.1_amd64.deb","SHA1Sum":"4ac856d35a43d3dcc4370ffb222b231a46e82444","SHA256Sum":"908372dac49325de0533112949507c0d17fb60466f2bd5c29c63fb50f7fdd8e0","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_93013fee33d943c18951b5045b","SupportedDevices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3936-304b59445054","Version":"HPK6"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-304b59445055","Version":"HPK6"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3330-3834-304b59445056","Version":"HPK6"},{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3730-3638-304b59445141","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"Samsung_PM9A3_GPM9A3SAHPK6.fwpkg","SHA1Sum":"f7b2a4cdf23cca06910d78b2ebfc23a2ac5a8605","SHA256Sum":"08e9d14dd7cae0b3670db0bc83ba12f3fd2f40a407f363283e58e28ec672518a","SHA512Sum":"69af49cee07d4c393e44f47cc135db5f25c25688a2737b9011836e2cdd791b47a1bcc0a07b829abd74e2cf5eda7699d8bc4db1f5d8f2e43aced6f6a5392dcc0d"}],"ComponentSizeInKB":3095,"CompsigList":[],"FileList":["payload.json","Samsung_PM9A3_GPM9A3SAHPK6.HPb","Samsung_PM9A3_GPM9A3SAHPK6.xml"],"Name":"Samsung_PM9A3_GPM9A3SAHPK6.fwpkg","SHA1Sum":"f7b2a4cdf23cca06910d78b2ebfc23a2ac5a8605","SHA256Sum":"08e9d14dd7cae0b3670db0bc83ba12f3fd2f40a407f363283e58e28ec672518a","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3936-304b59445054","562340a5-304b-3130-3932-304b59445055","562340a5-304b-3330-3834-304b59445056","562340a5-304b-3730-3638-304b59445141"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  VK000960KYDPT, VK001920KYDPU, VK003840KYDPV and VK007680KYDQA","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000960KYDPT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK001920KYDPU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK003840KYDPV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VK007680KYDQA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_46c24384109040aea7a6064e47","SupportedDevices":["562340a5-304b-3030-3936-304b59445054","562340a5-304b-3130-3932-304b59445055","562340a5-304b-3330-3834-304b59445056","562340a5-304b-3730-3638-304b59445141"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp073007.zip","SHA1Sum":"c987e451b7f5cc511afb1ace05cfe2adac7124bf","SHA256Sum":"f7431fb258504b4dd38f4be7391a8c2e121b0899ec30cd4ee0add6b303e9eea4","SHA512Sum":"80025bef1e5f1024fa2cb1253e45da7ad414619167e4352f19a10415a01adaf5d2c16069e0d2fbc248eac08c44ba72711763be8f2017bdba34e20155ccc875eb"}],"ComponentSizeInKB":586,"CompsigList":["cp073007.compsig"],"FileList":["/cp073007.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/index.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/vib20/icen/INT_bootbank_icen_2.6.5.0-1OEM.900.0.24755229.vib","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/icen-7127160694824065909.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-icen_2.6.5.0-1OEM.900.0.24755229.xml"],"Name":"cp073007.zip","SHA1Sum":"c987e451b7f5cc511afb1ace05cfe2adac7124bf","SHA256Sum":"f7431fb258504b4dd38f4be7391a8c2e121b0899ec30cd4ee0add6b303e9eea4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"icen","Version":"2.6.5.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"Intel icen Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-icen:2.6.5.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:2.6.5.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1d68588b779147c2ae2a8fbf32","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-124a80860001","a6b1a447-382a-5a4f-8086-124a80860008","a6b1a447-382a-5a4f-8086-124a80860004","a6b1a447-382a-5a4f-8086-124a80860002","a6b1a447-382a-5a4f-8086-124980860002","a6b1a447-382a-5a4f-8086-124980860005"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H08","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U47","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCD6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCD6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCD6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCD6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCD6XVUL12T8","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-5856-554c31325438","Version":"GPK8"},{"DeviceName":"KCD6XLUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c39363047","Version":"GPK8"},{"DeviceName":"KCD6XLUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31543932","Version":"GPK8"},{"DeviceName":"KCD6XLUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c33543834","Version":"GPK8"},{"DeviceName":"KCD6XLUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c37543638","Version":"GPK8"},{"DeviceName":"KCD6XLUL15T3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACD6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-3644-584c-554c31355433","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"CP070925.zip","SHA1Sum":"7da08468ac0b000e3c73db3b4b29c28325a66a5f","SHA256Sum":"87534bafa2c1063677e4dcc049e6528ea4b1949d156864ccd1c526039ddfe84e","SHA512Sum":"161a60b53131f3d021310afa661f6ce5d67c2d51a622eafe3e54141efe1ed0f77f36666ae09816382225e57fd217ae958d2308fdcf4c5cce57037b0dc3cab655"}],"ComponentSizeInKB":19940,"CompsigList":["CP070925.compsig"],"FileList":["/CP070925_BUILD_5.data","/CP070925.vmexe64","/CP070925.vmfile","/CP070925_VMw.zip","/CP070925.xml","/payload.json","/CP070925_VMw.zip/index.xml","/CP070925_VMw.zip/vendor-index.xml","/CP070925_VMw.zip/metadata.zip","/CP070925_VMw.zip/vib20/CP070925/HPE_bootbank_CP070925_GPK8.5-8.0.0.20613240.vib","/CP070925_VMw.zip/metadata.zip/vendor-index.xml","/CP070925_VMw.zip/metadata.zip/vmware.xml","/CP070925_VMw.zip/metadata.zip/vibs/CP070925-6561887990288194908.xml","/CP070925_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070925_GPK8.5-8.0.0.20613240.xml"],"Name":"CP070925.zip","SHA1Sum":"7da08468ac0b000e3c73db3b4b29c28325a66a5f","SHA256Sum":"87534bafa2c1063677e4dcc049e6528ea4b1949d156864ccd1c526039ddfe84e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-584c-554c31355433"],"TypeOfChange":"1","Version":"GPK8","VibList":[{"Name":"CP070925","Version":"GPK8.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - KCD6XVUL800G, KCD6XVUL1T60, KCD6XVUL3T20, KCD6XVUL6T40, KCD6XVUL12T8, KCD6XLUL960G, KCD6XLUL1T92, KCD6XLUL3T84, KCD6XLUL7T68 and KCD6XLUL15T3 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCD6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XVUL12T8","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCD6XLUL15T3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e34678c4a67f460192b88fd336","SupportedDevices":["002340a5-434b-3644-584c-554c37543638","002340a5-434b-3644-5856-554c36543430","002340a5-434b-3644-5856-554c31543630","002340a5-434b-3644-5856-554c38303047","002340a5-434b-3644-5856-554c33543230","002340a5-434b-3644-5856-554c31325438","002340a5-434b-3644-584c-554c39363047","002340a5-434b-3644-584c-554c31543932","002340a5-434b-3644-584c-554c33543834","002340a5-434b-3644-584c-554c31355433"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-6b7ce3da0e_0HPG2-2.1_amd64.deb","SHA1Sum":"3a551b4b6342b0cc2801592b90bf5d3c00f78357","SHA256Sum":"72a4fba14cf7efb9144ec7e90b4ef417166359bbcb3dd0f012b02d6c6595fbfc","SHA512Sum":"163beb91584d29926b8e2ac0a9e518f0f9e2855a8d16fe8d53671938af6a29858282992f58fa7c0f54ea84726f6f67999f739de5abc7e16c508c3fc355d831e2"}],"ComponentSizeInKB":4438,"CompsigList":["firmware-hdd-6b7ce3da0e_0HPG2-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/CP071735.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071735.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071735.scexe"],"Name":"firmware-hdd-6b7ce3da0e_0HPG2-2.1_amd64.deb","SHA1Sum":"3a551b4b6342b0cc2801592b90bf5d3c00f78357","SHA256Sum":"72a4fba14cf7efb9144ec7e90b4ef417166359bbcb3dd0f012b02d6c6595fbfc","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c58ad9f5f0084b4ebf812c3995","SupportedDevices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072686.zip","SHA1Sum":"322c9f9fc179fce50d6343894af76ebfd8727133","SHA256Sum":"af33aac32a33b9764459561e0d2e8d3250d306c44ccdd92214824f62b7e8d6ac","SHA512Sum":"edb2306d163657aedfad7d9668cdd4a36da1ddf4d772d455283e99215a493ac4b3283314662f5cea4b04d8c7f78f624e2a72b67d54ae88ad909f14873795afe8"}],"ComponentSizeInKB":383,"CompsigList":["cp072686.compsig"],"FileList":["/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip","/cp072686.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/index.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_238.1.147.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_238.1.147.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtroce-192341177695114936.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtnet--7805444915192846666.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.xml"],"Name":"cp072686.zip","SHA1Sum":"322c9f9fc179fce50d6343894af76ebfd8727133","SHA256Sum":"af33aac32a33b9764459561e0d2e8d3250d306c44ccdd92214824f62b7e8d6ac","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"bnxtroce","Version":"238.1.147.0-1OEM.900.0.24755229"},{"Name":"bnxtnet","Version":"238.1.147.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:238.1.247.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtroce:238.1.147.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtnet:238.1.147.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a31ca273c7334d8899c66f8c6f","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U46","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57416 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957416N4160HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d814e41592","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957416N4160HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ee14e41592","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57416 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957416N4160HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ef14e41592","Version":"238.1.169.0"}]},"Files":[{"Checksum":[{"Filename":"BCM238.1.169.0_BCM957416N4160HC.fwpkg","SHA1Sum":"33da959b74139d15bdb46a4691ce52617b971796","SHA256Sum":"110ce103c34c5c327d546327e8e9ab8c2b705ae708f3fffcca9cf58821b50e9d","SHA512Sum":"afdd24b6dccff25e76a26efa09a82da44fffd212944f7764b18b21ec9363ffc87ce29295571aa2533d09b6ad58270e3af834ab9caef83eca2f8962dbb60fe115"}],"ComponentSizeInKB":1608,"CompsigList":[],"FileList":["BCM238.1.169.0_BCM957416N4160HC.HPb","BCM238.1.169.0_BCM957416N4160HC.xml","payload.json"],"Name":"BCM238.1.169.0_BCM957416N4160HC.fwpkg","SHA1Sum":"33da959b74139d15bdb46a4691ce52617b971796","SHA256Sum":"110ce103c34c5c327d546327e8e9ab8c2b705ae708f3fffcca9cf58821b50e9d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41592"],"TypeOfChange":"1","Version":"238.1.169.0"}],"InstallationDependency":{},"Name":"Broadcom Firmware Package for BCM57416 OCP3 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE_57416OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_514cf4556ff647d982607379f2","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ef14e41592"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072097.exe","SHA1Sum":"8457d5973764d5a4edda877c75efc313e256e69c","SHA256Sum":"bacce6928643839f47035a252ebc1434565bd00be09aec579a447d092f765036","SHA512Sum":"5d929462aa9145f838f49d506af87f61273d5018e3ed61099db241efe18179385cc7baaedbe375f868f1bb4fd4c837a4483ab3cc24c2a61886514801d75e31ac"}],"ComponentSizeInKB":3491,"CompsigList":["cp072097.compsig"],"FileList":["cp072097.xml","cpqsetup.exe","cp_data.xml","genericmsi.dll","SSADU66590_X64.msi"],"Name":"cp072097.exe","SHA1Sum":"8457d5973764d5a4edda877c75efc313e256e69c","SHA256Sum":"bacce6928643839f47035a252ebc1434565bd00be09aec579a447d092f765036","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecdf9a8250"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"ssaducli.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssaducli\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_67b2f9aee63c4fadb663be4789","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A43","A43","A43","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A47","A48","U47","A46","U47","A42","U46","I44","U63","I45","U58","U59","U54","U54","U54","U63","U58","U58","A56","A56","A55","A55","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U57","U65","U65","U62","U71","U71","U68","U68","U72","A66","A66","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Files":[{"Checksum":[{"Filename":"firmware-d3000_6.00-3.1_amd64.deb","SHA1Sum":"9e43c92756a4ce261616d1f24b64d039bc5cdbee","SHA256Sum":"32ad158f9e25babd750b58503f39b36a1b9818bd9775377d7a337f2843174ff5","SHA512Sum":"a8066c3938f41e7c084bee05bf1eff1bb82ce1783bf3dc6060bbdde9ad8a95345ca4df660dc41d949f958885a68591b0f6cf5d8eb02fa6043c5448ebf337c4be"}],"ComponentSizeInKB":2316,"CompsigList":["firmware-d3000_6.00-3.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/CP072185.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/Reveille-Release-6.00-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072185.scexe","./usr/lib/x86_64-linux-gnu/firmware-d3000-6.00-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072185.scexe"],"Name":"firmware-d3000_6.00-3.1_amd64.deb","SHA1Sum":"9e43c92756a4ce261616d1f24b64d039bc5cdbee","SHA256Sum":"32ad158f9e25babd750b58503f39b36a1b9818bd9775377d7a337f2843174ff5","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1706b7d577f04dafbe67fa8bad","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 840z Mezzanine FIO Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4-rel-12_28_4706-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000EF","Version":"12.28.4706"},{"DeviceName":"HPE Apollo InfiniBand EDR 100Gb 2-port 841z Mezzanine Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900257","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900255","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"cp072409.exe","SHA1Sum":"17b616100bf4b4f247e704d4ded3b55d8057fb57","SHA256Sum":"8258d8a1cd833a1d02e547e53f25a5f241297115377fdfed36f9aa93ecde5767","SHA512Sum":"588f12d519cfdb131dea20cc2a54a5d938c8d79c60eda1e31b78068158b96fc1a19fc420c93a94066fb22f7077918e66cb00760b0ae9fcbbb38c216331df585e"}],"ComponentSizeInKB":26997,"CompsigList":["cp072409.compsig"],"FileList":["cp072409.xml","cpqsetup.exe","fw-ConnectX4-rel-12_28_4706-843400-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","fw-ConnectX5-rel-16_35_8008-872723-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","fw-ConnectX5-rel-16_35_8008-872725-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072409.exe","SHA1Sum":"17b616100bf4b4f247e704d4ded3b55d8057fb57","SHA256Sum":"8258d8a1cd833a1d02e547e53f25a5f241297115377fdfed36f9aa93ecde5767","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000EF","a6b1a447-382a-5a4f-15B3-101715900257","a6b1a447-382a-5a4f-15B3-101715900255"],"TypeOfChange":"1","Version":"1.0.0.18"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE Mellanox IB only ConnectX4 and ConnectX5 devices on Windows x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_IB_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_52e36eafdb29438aae24ab5ed2","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000ef","a6b1a447-382a-5a4f-15b3-101715900257","a6b1a447-382a-5a4f-15b3-101715900255"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A47","A48","U50","U47","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U19","U46","HPE Apollo 2000 Gen10 Plus System","U61","A41","U37","A42","U56","U27","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-41cdb1c9da-HPG3-5.1.x86_64.rpm","SHA1Sum":"8a1e2dcabe269dc301216be9324894bbe27f4279","SHA256Sum":"ec0826bea4e3419cb64cbd652f0985a5ef997549e0ffc8210c5b12a007011182","SHA512Sum":"3c972c69e9bd50e22532dc7dd0ddb6ad49e5c6ae129aae861bb8962a071909ab37779243362a6c41008862f13eb92a2cfd765d1db47ea5e3cd64fef0d9364e6e"}],"ComponentSizeInKB":6383,"CompsigList":["firmware-hdd-41cdb1c9da-HPG3-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/CP068848.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/WLEBsssATFG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-41cdb1c9da-HPG3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068848.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068848.scexe"],"Name":"firmware-hdd-41cdb1c9da-HPG3-5.1.x86_64.rpm","SHA1Sum":"8a1e2dcabe269dc301216be9324894bbe27f4279","SHA256Sum":"ec0826bea4e3419cb64cbd652f0985a5ef997549e0ffc8210c5b12a007011182","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWUDA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_26783d282a644af9b665b99090","SupportedDevices":["4d2340a5-3042-3431-3030-304757554441"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLHCCBA0HPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-aaf1014ede-HPD5-1.1.x86_64.rpm","SHA1Sum":"757323de371566b4c093a2734247c854d0dee949","SHA256Sum":"c5bb29255ec1059664f44d8d14e4756633564bc58708bd701227e26eb8064d2c","SHA512Sum":"234e56b7bb46817da9602092277bf4175f70f7d51a47a3c78fa9d649209431601ef4d2db8e78b47f88fd3acdb8d4da21c49715ffc489e503e8be8c571a606929"}],"ComponentSizeInKB":6170,"CompsigList":["firmware-hdd-aaf1014ede-HPD5-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/CP072249.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/WLHCCBA0HPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072249.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072249.scexe"],"Name":"firmware-hdd-aaf1014ede-HPD5-1.1.x86_64.rpm","SHA1Sum":"757323de371566b4c093a2734247c854d0dee949","SHA256Sum":"c5bb29255ec1059664f44d8d14e4756633564bc58708bd701227e26eb8064d2c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7d6aa1a7ebe547dcbf57ecee73","SupportedDevices":["4d2340a5-3042-3231-3030-304a57444644"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071901.exe","SHA1Sum":"f82faba6630eaaf2b8be098c0e9f3788d0af2a87","SHA256Sum":"e45c822a0e7d8729b27415a8eaa8f624598386afc03b565fe7006c485ec8733e","SHA512Sum":"ec072616b6d2706c78a8a6772a6a2d81ecb113ab6a24ea14cf3e81febb95292996688253397d72a28b5b062936d05f1708a51b8250efec355cde62a919390ea3"}],"ComponentSizeInKB":790,"CompsigList":["cp071901.compsig"],"FileList":["cp071901.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","smartpqi.cat","smartpqi.inf","SmartPqi.sys"],"Name":"cp071901.exe","SHA1Sum":"f82faba6630eaaf2b8be098c0e9f3788d0af2a87","SHA256Sum":"e45c822a0e7d8729b27415a8eaa8f624598386afc03b565fe7006c485ec8733e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"TypeOfChange":"1","Version":"1016.38.0.1003"}],"InstallationDependency":{},"Name":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2022 and Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"SmartPqi.sys","SWKeyExpectedPath":"%systemdrive%\\cpqsystem\\pnpdrvs"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fa741ed6213f4d85b53532d541","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","A43","U48","U46","U46","A42","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U60","U61","I45","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U58","U59","U63","I44","U57","U65","U65","U62","U71","A66","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"cp068757.exe","SHA1Sum":"c5556e20e4d511de3fed10f8293d1becb63e6d68","SHA256Sum":"db528426cdce592b369e2bc13677c63c7d9191c827eb28148babdc156b938f1f","SHA512Sum":"8f4c6a2685a9c4eebc2feebec6dbdc58621a83e2aac038fd0d69df8eaf2cf8d1061e4bfbad5b8424c83e4fe2d266ee1f7b021b474b58529a6b502f8e8f865bd5"}],"ComponentSizeInKB":3203,"CompsigList":["cp068757.compsig"],"FileList":["cp068757.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG06scHPD9.REL"],"Name":"cp068757.exe","SHA1Sum":"c5556e20e4d511de3fed10f8293d1becb63e6d68","SHA256Sum":"db528426cdce592b369e2bc13677c63c7d9191c827eb28148babdc156b938f1f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWJRQ and MB006000JWJRP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_76ebd18092bc4839b75f22e866","SupportedDevices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp073058.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.216"}]},"Files":[{"Checksum":[{"Filename":"firmware-microservergen10plussps-05.01.05.216-1.1.x86_64.rpm","SHA1Sum":"3e1d40e22f62807c84d06047f441e7dfd650b7ae","SHA256Sum":"c9fd0a4dded280e541a7acc9f494619f006d6966622bfa69bd74cfb54e2d45b8","SHA512Sum":"3fb139007e05eb1b4dd230399e23e91db68f8335f891ed31d9d93ca5a1594a97630c3af1d4d4349537e4820bf96474874327b30d5004dc69caae899f20ab258a"}],"ComponentSizeInKB":2132,"CompsigList":["firmware-microservergen10plussps-05.01.05.216-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1/CP073062.xml","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1/cp073058.compsig","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1/cp073058.zip","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-microservergen10plussps-05.01.05.216-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073062.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073062.scexe"],"Name":"firmware-microservergen10plussps-05.01.05.216-1.1.x86_64.rpm","SHA1Sum":"3e1d40e22f62807c84d06047f441e7dfd650b7ae","SHA256Sum":"c9fd0a4dded280e541a7acc9f494619f006d6966622bfa69bd74cfb54e2d45b8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.216"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_968b1c271ba046cbaa18725e66","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U48"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLHCWBA0HPG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-059b8654a6-HPG6-1.1.x86_64.rpm","SHA1Sum":"d3dc0e2377ba2b702b26f536318d4d3cf24654b2","SHA256Sum":"748c74713fb9759f8add5139e0fdac47546ec8daa5df6af870132a26a4ee4827","SHA512Sum":"63ee98ad11127ed419ad052b127b97f8908463549dff6a8625d5deb8b98e863be891ff5883b9742b9559774a6caba1e997e4b2d08871de2ce4d9820ef8f15421"}],"ComponentSizeInKB":6184,"CompsigList":["firmware-hdd-059b8654a6-HPG6-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/CP072238.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/WLHCWBA0HPG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072238.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072238.scexe"],"Name":"firmware-hdd-059b8654a6-HPG6-1.1.x86_64.rpm","SHA1Sum":"d3dc0e2377ba2b702b26f536318d4d3cf24654b2","SHA256Sum":"748c74713fb9759f8add5139e0fdac47546ec8daa5df6af870132a26a4ee4827","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWDFE Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3782d66ff7504cc9b8caabdc77","SupportedDevices":["4d2340a5-3042-3231-3030-304757444645"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069550.exe","SHA1Sum":"992fe0d542e99ec44af8166c0d379c7c7e39cf93","SHA256Sum":"4acd8f6e53a5866b135665830f22c7e1e9387aef8458a577d7f6d79ce4114643","SHA512Sum":"d23f754d7aed622fa920bc6269bbde2ba0828074a2dc6a96841c91eafd27978d15591d740c8c609a18332f95b62fa4be32455801b97389bc02510a6a1630a593"}],"ComponentSizeInKB":1015,"CompsigList":["cp069550.compsig"],"FileList":["cp069550.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs68x64.cat","ixs68x64.din","ixs68x64.inf","ixs68x64.sys","ixsmsg.dll","nicdrvr.dll"],"Name":"cp069550.exe","SHA1Sum":"992fe0d542e99ec44af8166c0d379c7c7e39cf93","SHA256Sum":"4acd8f6e53a5866b135665830f22c7e1e9387aef8458a577d7f6d79ce4114643","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecee44d472"],"TypeOfChange":"1","Version":"4.1.254.0"}],"InstallationDependency":{},"Name":"HPE Intel ixs Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"ixs68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_139342fddb704f7abff074902a","SupportedDevices":["a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3630-3030-304759444e4c","Version":"HPG4"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3830-3030-304759445045","Version":"HPG4"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPETG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3031-3030-304759444e4e","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"Seagate_CimarronBP_SCIMARBPETG4.fwpkg","SHA1Sum":"842440cd46a3b456897604f5efb5a636c98ce85d","SHA256Sum":"1380d55773ddcd4828e2d6388a5be330499d38c17c8d9ba9a58c4ef2c4c4df1c","SHA512Sum":"20cbb8d97053d1835429befc0de740aa69f5145d465d6f888a5321e7d74f0d22d70dc480d7ac87aedda1f382e3fe77fa798202ba30e98314a9154644585e0ca8"}],"ComponentSizeInKB":2562,"CompsigList":[],"FileList":["payload.json","Seagate_CimarronBP_SCIMARBPETG4.HPb","Seagate_CimarronBP_SCIMARBPETG4.xml"],"Name":"Seagate_CimarronBP_SCIMARBPETG4.fwpkg","SHA1Sum":"842440cd46a3b456897604f5efb5a636c98ce85d","SHA256Sum":"1380d55773ddcd4828e2d6388a5be330499d38c17c8d9ba9a58c4ef2c4c4df1c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304759444e4c","4d2340a5-3042-3830-3030-304759445045","4d2340a5-3042-3031-3030-304759444e4e"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB006000GYDNL, MB008000GYDPE and MB010000GYDNN","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GYDNL","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB008000GYDPE","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB010000GYDNN","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0be86abeb599456ea5c1845fc6","SupportedDevices":["4d2340a5-3042-3630-3030-304759444e4c","4d2340a5-3042-3830-3030-304759445045","4d2340a5-3042-3031-3030-304759444e4e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-ixgbe-6.4.4-1.rhel10u1.x86_64.rpm","SHA1Sum":"36782112ee027c0f6cc12bdad6ade8d435ca93f1","SHA256Sum":"548dd46b41c634008d3ea5c6d192f07ddf6c2d74841e4e014aa792276bea6add","SHA512Sum":"847e132329bebe5ffb4989587c2330d0bf1f2609dce3be19ffce21990f71f58965d7ae57da71a1f60a705e2f01e9d3f89e5af74421bd244797d2022908e40d09"}],"ComponentSizeInKB":444,"CompsigList":["kmod-ixgbe-6.4.4-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ixgbe.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/ixgbe/ixgbe.ko","./usr/share/doc/kmod-ixgbe","./usr/share/doc/kmod-ixgbe/COPYING","./usr/share/doc/kmod-ixgbe/README","./usr/share/doc/kmod-ixgbe/pci.updates","./usr/share/man/man7/ixgbe.7.gz","./usr/share/smartupdate/kmod-ixgbe/component.xml"],"Name":"kmod-ixgbe-6.4.4-1.rhel10u1.x86_64.rpm","SHA1Sum":"36782112ee027c0f6cc12bdad6ade8d435ca93f1","SHA256Sum":"548dd46b41c634008d3ea5c6d192f07ddf6c2d74841e4e014aa792276bea6add","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec510c02b3"],"TypeOfChange":"1","Version":"6.4.4-1"},{"Checksum":[{"Filename":"kmod-ixgbe-6.4.4-1.rhel10u2.x86_64.rpm","SHA1Sum":"a4d0e302d7755e0c6436162f80300d3d54f6918b","SHA256Sum":"e3a47eca108aaa2fb1742432f040db2b7c355922f5f05a92d994fc9e5f2efafa","SHA512Sum":"87a0ad505fbf7019ac6b4685b5c193be800637eb46df3f90cae73d929efc300ad70a23bb0fff42fe3921d7c1fc423a612ab106fdb8a417a4ded4958fbd2e540c"}],"ComponentSizeInKB":444,"CompsigList":["kmod-ixgbe-6.4.4-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ixgbe.conf","./lib/modules/6.12.0-211.7.1.el10_2.x86_64/extra/ixgbe/ixgbe.ko","./usr/share/doc/kmod-ixgbe","./usr/share/doc/kmod-ixgbe/COPYING","./usr/share/doc/kmod-ixgbe/README","./usr/share/doc/kmod-ixgbe/pci.updates","./usr/share/man/man7/ixgbe.7.gz","./usr/share/smartupdate/kmod-ixgbe/component.xml"],"Name":"kmod-ixgbe-6.4.4-1.rhel10u2.x86_64.rpm","SHA1Sum":"a4d0e302d7755e0c6436162f80300d3d54f6918b","SHA256Sum":"e3a47eca108aaa2fb1742432f040db2b7c355922f5f05a92d994fc9e5f2efafa","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec510c02b3"],"TypeOfChange":"1","Version":"6.4.4-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbe Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ixgbe","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ixgbe","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3b117e96360a4e04af1266d67a","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U68","U68","U68","U71","U69","A58","U69","U71","U72","U68","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a07a420ed1_0HPD5-2.1_amd64.deb","SHA1Sum":"8b29852e27e19667777c8df9f76e6219706cb87f","SHA256Sum":"ee836d4d9f421e91dc35a91b15629147f029473f3c84b4c2f03c33e0c14763d8","SHA512Sum":"53906b7d3ccf6b459907047f56f7fcde8e899f70671dc8801cd9cb9fa823273b9ecbfcccb68053b284ffab417c79788844bcf49cf9fe3609bde87a55bfca5553"}],"ComponentSizeInKB":3654,"CompsigList":["firmware-hdd-a07a420ed1_0HPD5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/CP071750.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/GPM1645ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071750.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a07a420ed1-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071750.scexe"],"Name":"firmware-hdd-a07a420ed1_0HPD5-2.1_amd64.deb","SHA1Sum":"8b29852e27e19667777c8df9f76e6219706cb87f","SHA256Sum":"ee836d4d9f421e91dc35a91b15629147f029473f3c84b4c2f03c33e0c14763d8","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_03da487f589342e099df1431ab","SupportedDevices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 548SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-P11338-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159002C1","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072381.zip","SHA1Sum":"e4d6869a59dfa2714e1fd6bcfa9e8a3042efbb33","SHA256Sum":"7df51076a33bac3533cedbbe045df9d873dc2d85047bac50d12dedb139c3148f","SHA512Sum":"7c512b0fd86bf0d3c784ba74440a88f9260fcedd683b7a3545cb10dae4331dbedd61b6ac745880fceb3a50a72b8b4951529fea6a51c9854400e543461349b0cc"}],"ComponentSizeInKB":16290,"CompsigList":["CP072381.compsig"],"FileList":["/CP072381.xml","/CP072381_VMw.zip","/payload.json","/CP072381.vmexe64","/CP072381.vmfile","/CP072381_VMw.zip/index.xml","/CP072381_VMw.zip/vendor-index.xml","/CP072381_VMw.zip/metadata.zip","/CP072381_VMw.zip/vib20/CP072381/HPE_bootbank_CP072381_1.0.2-1OEM.900.0.24755229.vib","/CP072381_VMw.zip/metadata.zip/vendor-index.xml","/CP072381_VMw.zip/metadata.zip/vmware.xml","/CP072381_VMw.zip/metadata.zip/vibs/CP072381-7047738796017372873.xml","/CP072381_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072381_1.0.2-1OEM.900.0.24755229.xml"],"Name":"CP072381.zip","SHA1Sum":"e4d6869a59dfa2714e1fd6bcfa9e8a3042efbb33","SHA256Sum":"7df51076a33bac3533cedbbe045df9d873dc2d85047bac50d12dedb139c3148f","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.1.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1015159002C1"],"TypeOfChange":"1","Version":"1.0.3","VibList":[{"Name":"CP072381","Version":"1.0.2-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 9.x) for HPE Ethernet 10Gb 2-port 548SFP+ Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_768259f2d4064386950b73a309","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1015159002c1"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U32","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","U37"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072293.exe","SHA1Sum":"63b4f09772a1467aa054e7e5b303c769d630e0a3","SHA256Sum":"d3c0e822aafdac22b161f668f3d3128d49886a5875e5e87ca0e50621ed8f20ab","SHA512Sum":"e34e7c7717d9c2aa8012923e8108be6757fad618822328d3be380cf53be232aa00a7d8a20bab25b5a3060902bd94ce8fe3c9b2ef319348a043ff83da9e99e39c"}],"ComponentSizeInKB":584,"CompsigList":["cp072293.compsig"],"FileList":["cp072293.xml","cpqsetup.exe","generic.dll","install.xml","nechesasr.cat","nechesasr.inf","nechesasr.sys","scripts/","scripts/Get-AsrSettings.ps1","scripts/Set-AsrPreTimeoutNMI.ps1","scripts/Set-AsrTimeout.ps1"],"Name":"cp072293.exe","SHA1Sum":"63b4f09772a1467aa054e7e5b303c769d630e0a3","SHA256Sum":"d3c0e822aafdac22b161f668f3d3128d49886a5875e5e87ca0e50621ed8f20ab","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec215b6a97"],"TypeOfChange":"0","Version":"4.7.1.0"}],"InstallationDependency":{},"Name":"iLO 5 Automatic Server Recovery Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"nechesasr.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_84e5ca253cd54184b167df1077","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U36","U43","U41","U33","U44","A47","U40","U39","U45","U37","A46","U38","U38","U48","I43","I42","U46","U46","U47","U47","U50","I44","U61","U60","U56","A43","A42","A43","A42","A48","U50","U40","U39","U64","H10","H10","H08","H10","H08"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM6 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM6_1.06_C.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"9675b54e-1c96-44c3-a7a1-901506000000","Version":"1.06"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM6_1.06_C.fwpkg","SHA1Sum":"d8f757a2385ab268684855c04d5f3ee2a0ccf41d","SHA256Sum":"36078ab3983e421460463905c6c01415462d5d42997adf60a5e58772dc5ac31d","SHA512Sum":"9442e9ff77d6cf87cc87499fe21f7410c89b2a2ba22e3f5ceab87cdb6e924033428d6e90efc8b8d7eff2a99f2fe840326e098c5628fcd9db46f215d0acf6cf8f"}],"ComponentSizeInKB":121,"CompsigList":[],"FileList":["HPE_UBM6_1.06_C.HPb"],"Name":"HPE_UBM6_1.06_C.fwpkg","SHA1Sum":"d8f757a2385ab268684855c04d5f3ee2a0ccf41d","SHA256Sum":"36078ab3983e421460463905c6c01415462d5d42997adf60a5e58772dc5ac31d","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901506000000"],"TypeOfChange":"1","Version":"1.06"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"Name":"Firmware Package - UBM6 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11/Gen12 servers usage","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM6PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8d2f93658aad402bbbab030a31","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","7.0","12.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A56","A56","A55","A55","U54","U54","U54","U63","U58","U63","U59","I45","U46","U30","A42","U46","U32","A43","A43","A42","U46","U69","R11","U71","U71","U68","U68","U72","U68","I46"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A40_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a40-3.80_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"d7b2ebc4c96a7ff7f42fa725997e76d6c5826beb","SHA256Sum":"3ec0d4961355f8506e94e37bbc4e0cc9c8ac85c5bac9dd1f7dc0aba062600ba2","SHA512Sum":"3e361f290647d839195a30bc1f9e1802f5bdb3471ea4b3cdbc4e702d825850d4c6285a199efc1b3c52b9f0f3dd02b500c14d6dddbf593b8d0ed5b4d8578defdb"}],"ComponentSizeInKB":17609,"CompsigList":["firmware-system-a40-3.80_2026_05_28-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/A40_3.80_05_28_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/CP072017.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a40-3.80_2026_05_28-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072017.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072017.scexe"],"Name":"firmware-system-a40-3.80_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"d7b2ebc4c96a7ff7f42fa725997e76d6c5826beb","SHA256Sum":"3ec0d4961355f8506e94e37bbc4e0cc9c8ac85c5bac9dd1f7dc0aba062600ba2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL385 Gen10 (A40) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c6a1656defb24fbaa92badd433","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A40"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"sut-6.9.0-75.linux.x86_64.rpm","SHA1Sum":"77ff1edf01e2bd8e9d2fca43fc5bec268eeee04c","SHA256Sum":"1876654dadb14abb64ba28e7a780688ae305a593ee998312b0bbc7754005978d","SHA512Sum":"db743571d8e57ef1a8d366e48c11edf72931d3363ae42f30ccd003d957ca219277d5df628d1bf985c53787a4f32f077dad3d5490a0e98c1b882bbba07424c9b5"}],"ComponentSizeInKB":9599,"CompsigList":["sut-6.9.0-75.linux.x86_64.compsig"],"FileList":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/816b227696b91815670f9329216c873743e950","./usr/lib/.build-id/95","./usr/lib/.build-id/95/14bec01bfd84c7aed6f15532b3d7373e2b5853","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"Name":"sut-6.9.0-75.linux.x86_64.rpm","SHA1Sum":"77ff1edf01e2bd8e9d2fca43fc5bec268eeee04c","SHA256Sum":"1876654dadb14abb64ba28e7a780688ae305a593ee998312b0bbc7754005978d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"6.9.0.0"}],"InstallationDependency":{},"MinimumActiveVersion":"5.3.0","Name":"Integrated Smart Update Tools for Linux x64","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0d079a2f41b0438cbb6b475d68","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-103c-3307159004bd","a6b1a447-382a-5a4f-103c-3306159004bd","a6b1a447-382a-5a4f-102b-053a159004bd"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["HP Smart Update Tools (HP SUT)","A55","A55","A56","A56","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","U37","A46","U47","U38","U38","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","SPP","A42","U56","U61","U60","U64","U46","I43","I44","I42","I45","U65","U65","U58","U59","U63","U62","U63","U54","U58","U58","U69","U71","U69","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U72","U77","R13","U70","H08","H10","U54","U54","U57","U65","H11","A58","A59","U66","U68","A66","U74","A66","U71","U77","A72","HPE ProLiant Compute DL384VR Gen13","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG4"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG4"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG4"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG4"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG4"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"cp072125.exe","SHA1Sum":"eb4a6dc85cd145a837f97d23ce7d070bd942715b","SHA256Sum":"421acde3f433fb673d9d2dc2a5343ef0035783dd76f9baf876d60e8859c0bc00","SHA512Sum":"d86f8118cbf42d5d6345e3ac85add8502a279007176fda6125408e4459c16f2900da25da907e4267603c5e887122f0f1b96db7678fa64d1f92a6e40337a9aa0f"}],"ComponentSizeInKB":3304,"CompsigList":["cp072125.compsig"],"FileList":["cp072125.xml","cpqsetup.exe","M52002TBHPG4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp072125.exe","SHA1Sum":"eb4a6dc85cd145a837f97d23ce7d070bd942715b","SHA256Sum":"421acde3f433fb673d9d2dc2a5343ef0035783dd76f9baf876d60e8859c0bc00","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWSXF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWSXH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWSXK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWUGF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWUGH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWUGK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0ea92126033f4244a2f4aa640b","SupportedDevices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100","10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57414 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957414N4140HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41596","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957414N4140HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41596","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 OCP3 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957414N4140HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41596","Version":"238.1.169.0"}]},"Files":[{"Checksum":[{"Filename":"BCM238.1.169.0_BCM957414N4140HC.fwpkg","SHA1Sum":"15cb91966d9943a16f46cae50084ad5b355721eb","SHA256Sum":"e9c9a5600712519b04763937f5b477d1e94ec2553f7f8efb8076224a140eb7ee","SHA512Sum":"cf4dd7a2bb8805580bcb7af0778ddac33ec640ce81241893f5ddf76c28c8bc1d821613e0a4c955d83df249ad1c76b337fb982aeb9fae0da8480bf33b2fc64574"}],"ComponentSizeInKB":1430,"CompsigList":[],"FileList":["BCM238.1.169.0_BCM957414N4140HC.HPb","BCM238.1.169.0_BCM957414N4140HC.xml","payload.json"],"Name":"BCM238.1.169.0_BCM957414N4140HC.fwpkg","SHA1Sum":"15cb91966d9943a16f46cae50084ad5b355721eb","SHA256Sum":"e9c9a5600712519b04763937f5b477d1e94ec2553f7f8efb8076224a140eb7ee","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596"],"TypeOfChange":"1","Version":"238.1.169.0"}],"InstallationDependency":{},"Name":"Broadcom Firmware Package for BCM57414 OCP3 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE_957414OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6a79b38ffa4f4bab94ad18f163","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16ec14e41596"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U61","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U61_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023c","Version":"v2.70 (08/20/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073271.exe","SHA1Sum":"5845489a4b367fb3dbefd35485d18507197f5ccc","SHA256Sum":"2a3ddc32d194cd98eb48e9f055b45d6b17876de4ecd9cad89f23c497a0f1d8ae","SHA512Sum":"e40f0837e8b799a13a16038be1f41c9bb93dbc480b85575d24e7e6c7a34b1a9a4cc1c67a62c3a7b1cbd69b9b14c341d68af2c19a1fdde9384165981544e75ac9"}],"ComponentSizeInKB":17046,"CompsigList":["cp073271.compsig"],"FileList":["cp073271.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U61_2.70_08_20_2026.signed.flash"],"Name":"cp073271.exe","SHA1Sum":"5845489a4b367fb3dbefd35485d18507197f5ccc","SHA256Sum":"2a3ddc32d194cd98eb48e9f055b45d6b17876de4ecd9cad89f23c497a0f1d8ae","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023c"],"TypeOfChange":"1","Version":"2.70_08-20-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant ML30 Gen10 Plus Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U61","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6c2fa7fc9a50419d9ef2e8a254","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3438-3047584e5842","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3936-3047584e5a4b","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3030-3936-3053584e5843","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3130-3932-3047584e5a4c","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3130-3932-3053584e5a50","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304b-3330-3834-3047584e5a4e","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3234-3047584e5755","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3438-3047584e5a41","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3438-3053584e5756","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3030-3936-3047584e5a42","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-3047584e5a43","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3130-3932-3053584e5a46","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3330-3834-3047584e5a44","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304b-3730-3638-3047584e5a45","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3234-3047584e5841","Version":"HPG1"},{"DeviceName":"Micron-5400-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_5400_M5400ALLHPG1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-3047584e5a48","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"Micron_5400_M5400ALLHPG1.fwpkg","SHA1Sum":"27aee03c83eca71eef5cec16d5fa21b6125d949c","SHA256Sum":"8983bfd85cf5d061b13ae383f81c8907a90f1a737b7910ff88e0f255ba4cbb4c","SHA512Sum":"0894d1d5cea5a027b2ef3571b34831842b261eb9f288f28e314aff4760df709ba7528d074df4016a22817a7ae71551cbaf86454fdf0534d97c476431bf528ed1"}],"ComponentSizeInKB":4812,"CompsigList":[],"FileList":["Micron_5400_M5400ALLHPG1.HPb","Micron_5400_M5400ALLHPG1.xml","payload.json"],"Name":"Micron_5400_M5400ALLHPG1.fwpkg","SHA1Sum":"27aee03c83eca71eef5cec16d5fa21b6125d949c","SHA256Sum":"8983bfd85cf5d061b13ae383f81c8907a90f1a737b7910ff88e0f255ba4cbb4c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-3047584e5842","4d2340a5-304b-3030-3936-3047584e5a4b","4d2340a5-304b-3030-3936-3053584e5843","4d2340a5-304b-3130-3932-3047584e5a4c","4d2340a5-304b-3130-3932-3053584e5a50","4d2340a5-304b-3330-3834-3047584e5a4e","562340a5-304b-3030-3234-3047584e5755","562340a5-304b-3030-3438-3047584e5a41","562340a5-304b-3030-3438-3053584e5756","562340a5-304b-3030-3936-3047584e5a42","562340a5-304b-3130-3932-3047584e5a43","562340a5-304b-3130-3932-3053584e5a46","562340a5-304b-3330-3834-3047584e5a44","562340a5-304b-3730-3638-3047584e5a45","562340a5-3052-3030-3234-3047584e5841","562340a5-3052-3030-3438-3047584e5a48"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Universal Firmware Package for Drives - MK000480GXNXB, MK000960GXNZK, MK001920GXNZL, MK003840GXNZN, VK000240GXNWU, VK000480GXNZA, VK000960GXNZB, VK001920GXNZC, VK003840GXNZD, VK007680GXNZE, VK000480SXNWV, VK001920SXNZF, MK000960SXNXC and MK001920SXNZP","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GXNXB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GXNZK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GXNZL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GXNZN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GXNWU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GXNZA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GXNZB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GXNZC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GXNZD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GXNZE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480SXNWV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920SXNZF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960SXNXC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920SXNZP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VR000240GXNXA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VR000480GXNZH","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_02859ac29430461593ee92cdbd","SupportedDevices":["4d2340a5-304b-3030-3438-3047584e5842","4d2340a5-304b-3030-3936-3047584e5a4b","4d2340a5-304b-3130-3932-3047584e5a4c","4d2340a5-304b-3330-3834-3047584e5a4e","562340a5-304b-3030-3234-3047584e5755","562340a5-304b-3030-3438-3047584e5a41","562340a5-304b-3030-3936-3047584e5a42","562340a5-304b-3130-3932-3047584e5a43","562340a5-304b-3330-3834-3047584e5a44","4d2340a5-304b-3030-3936-3053584e5843","4d2340a5-304b-3130-3932-3053584e5a50","562340a5-304b-3130-3932-3053584e5a46","562340a5-304b-3030-3438-3053584e5756","562340a5-304b-3730-3638-3047584e5a45","562340a5-3052-3030-3234-3047584e5841","562340a5-3052-3030-3438-3047584e5a48"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp068736.exe","SHA1Sum":"d2555ff54cbe38ca56f7ae1fcdc9698cc9708ae2","SHA256Sum":"1d8695c16716ee1f7ac34baccdeaa9f78e3bd81d8ba3e1cd872c0b7e993c4db2","SHA512Sum":"2270d275486e440dc0e39ebc1cf29d7b23665e4cf457cb65cd254b04efc4ecafcb4840119e50627cef6cbbdb19ad522ca46e92bfa657a9bbf9cd65dcae67c519"}],"ComponentSizeInKB":4404,"CompsigList":["cp068736.compsig"],"FileList":["cp068736.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARBPNSD6.rel","setup.dll"],"Name":"cp068736.exe","SHA1Sum":"d2555ff54cbe38ca56f7ae1fcdc9698cc9708ae2","SHA256Sum":"1d8695c16716ee1f7ac34baccdeaa9f78e3bd81d8ba3e1cd872c0b7e993c4db2","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB002000JYDNE and MB004000JYDPB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_98f0ab5aa0074cff977bf2a348","SupportedDevices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U37_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u37-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"8c5964585f1dd6f85cfc20e05e9954a16977a840","SHA256Sum":"db6f47ed854f2186bce65c30f4be779dcbe1cd051e9cd2b40a3bb95553e9e2b1","SHA512Sum":"809851dc022f4be3507e054a39a6d97861f0b5509d5f8489afb1a63a9d803d891b0e869085e3b0a0af1fc5408966d5bebc5470b99428c63f062d55dddd3293dd"}],"ComponentSizeInKB":11348,"CompsigList":["firmware-system-u37-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.70_2026_08_19-1.1/CP073176.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.70_2026_08_19-1.1/U37_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u37-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073176.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073176.scexe"],"Name":"firmware-system-u37-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"8c5964585f1dd6f85cfc20e05e9954a16977a840","SHA256Sum":"db6f47ed854f2186bce65c30f4be779dcbe1cd051e9cd2b40a3bb95553e9e2b1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant XL230k Gen10 (U37) Server","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8c760e7573304e1681ee6a1a63","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","11.0","7.0","6.0","15.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U37"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSSD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3432-3030-304a59455645","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Seagate_Summit_SUMMITSUSSD3.fwpkg","SHA1Sum":"78ccea21d0e3d89d7de5138d3e62155cf39cb078","SHA256Sum":"b757e443c9fd1481c37b651d9e4a08ebfcd60ae7cf9f5de03ebdafa9c0863913","SHA512Sum":"3e37c790469677483d8344f7b1a7c95d4cd0d586975276b7637e114b492ba046314b2ab2e8a2bbdaa539918514b31ff26bd42db94b5a5671c0a50d68bbfcc58e"}],"ComponentSizeInKB":3679,"CompsigList":[],"FileList":["payload.json","Seagate_Summit_SUMMITSUSSD3.HPb","Seagate_Summit_SUMMITSUSSD3.xml"],"Name":"Seagate_Summit_SUMMITSUSSD3.fwpkg","SHA1Sum":"78ccea21d0e3d89d7de5138d3e62155cf39cb078","SHA256Sum":"b757e443c9fd1481c37b651d9e4a08ebfcd60ae7cf9f5de03ebdafa9c0863913","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-424d-3432-3030-304a59455645"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB24000JYEVE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB24000JYEVE","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_54c9602889d54d00bfe7cae757","SupportedDevices":["002340a5-424d-3432-3030-304a59455645"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.5"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.5"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.5"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//B1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.5"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.5-1//firmware//P1447315.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.5"}]},"Files":[{"Checksum":[{"Filename":"cp071321.exe","SHA1Sum":"06656463282ab83ce9b4cb2ac65551dd634ccadd","SHA256Sum":"583eec777a41e327fa6d69f2e531df3bbc46b7441f6647b75d68f73f255a92c6","SHA512Sum":"a904f9337b81f60e9fefbce193bceaf056b7c920dfd20a0fade2a2386547f3b0b2c9167845f08b1eb9981d263d6129650a6432dd52e428175cef712832bad2ba"}],"ComponentSizeInKB":4467,"CompsigList":["cp071321.compsig"],"FileList":["cp071321.xml","cpqsetup.exe","elxflashStandalone-windows-14.4.731.5-1/firmware/","elxflashStandalone-windows-14.4.731.5-1/firmware/B1447315.grp","elxflashStandalone-windows-14.4.731.5-1/firmware/P1447315.grp","elxflashStandalone-windows-14.4.731.5-1/win/","elxflashStandalone-windows-14.4.731.5-1/win/elxflash.bat","elxflashStandalone-windows-14.4.731.5-1/win/winlpcfg.bat","elxflashStandalone-windows-14.4.731.5-1/win/x64/","elxflashStandalone-windows-14.4.731.5-1/win/x64/elxflash.exe","elxflashStandalone-windows-14.4.731.5-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-14.4.731.5-1/win/x64/libdfc.dll","elxflashStandalone-windows-14.4.731.5-1/win/x64/readme.txt","elxflashStandalone-windows-14.4.731.5-1/win/x64/RM.INI","elxflashStandalone-windows-14.4.731.5-1/win/x64/WinLpCfg.exe","fwmatrix.txt","elxflashStandalone-windows-14.4.731.5-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","reference.xml"],"Name":"cp071321.exe","SHA1Sum":"06656463282ab83ce9b4cb2ac65551dd634ccadd","SHA256Sum":"583eec777a41e327fa6d69f2e531df3bbc46b7441f6647b75d68f73f255a92c6","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2016/2019 x64","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_366a2fedcb0c4b1a941ad360ef","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSND3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3231-3030-304a5945534e","Version":"HPD3"},{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSND3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3631-3030-304a59455643","Version":"HPD3"},{"DeviceName":"Seagate-Summit-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Summit_SUMMITSUSND3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-424d-3032-3030-304a59455644","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Seagate_Summit_SUMMITSUSND3.fwpkg","SHA1Sum":"7f2b1192df02cde396e7efcb7c3674f0fddc652d","SHA256Sum":"1452e5d30ef9fa05e95baf7a678ccc8829560d560eea739188b9812298215723","SHA512Sum":"ef0fbebe30bd3b39dc37fb7deba9d1d26840978ece723b1ce93762ca990009783b261d496e1a695834271d7bfc45ba9b476ba9b2e4ae2c5721d929e1fa713fe4"}],"ComponentSizeInKB":3682,"CompsigList":[],"FileList":["payload.json","Seagate_Summit_SUMMITSUSND3.HPb","Seagate_Summit_SUMMITSUSND3.xml"],"Name":"Seagate_Summit_SUMMITSUSND3.fwpkg","SHA1Sum":"7f2b1192df02cde396e7efcb7c3674f0fddc652d","SHA256Sum":"1452e5d30ef9fa05e95baf7a678ccc8829560d560eea739188b9812298215723","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-424d-3231-3030-304a5945534e","002340a5-424d-3631-3030-304a59455643","002340a5-424d-3032-3030-304a59455644"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB12000JYESN, MB16000JYEVC, MB20000JYEVD","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB12000JYESN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB16000JYEVC","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MB20000JYEVD","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_83ab6972351c42d3b0ce1fc4cf","SupportedDevices":["002340a5-424d-3231-3030-304a5945534e","002340a5-424d-3631-3030-304a59455643","002340a5-424d-3032-3030-304a59455644"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070019.zip","SHA1Sum":"83a39a47c7c3467bd16cf53addf0860ea05d772b","SHA256Sum":"d426d861c24500204e130f618f3ad4b67f9ecd8ba8442e2ae64a690907053bf8","SHA512Sum":"1f74f9f7e4c7b1bc80133d3e2983f230c73c76e06c17fa206f6f1ef07ee5030ff6aef8b9dc737cfc480a07179f58036e97704326be54dce61b1396f50f8b249f"}],"ComponentSizeInKB":21,"CompsigList":["cp070019.compsig"],"FileList":["/cp070019.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/index.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/vendor-index.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/vib20/ilo/HPE_bootbank_ilo_800.10.9.1.4-1OEM.800.1.0.20613240.vib","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/ilo--1061765975396018296.xml","/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/ilo-driver_800.10.9.1.4-1OEM.800.1.0.20613240.xml"],"Name":"cp070019.zip","SHA1Sum":"83a39a47c7c3467bd16cf53addf0860ea05d772b","SHA256Sum":"d426d861c24500204e130f618f3ad4b67f9ecd8ba8442e2ae64a690907053bf8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec948d20a3","20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"ilo","Version":"800.10.9.1.4-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE iLO Driver Bundle Smart Component for ESXi 8.0 and ESXi 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"ilo-driver:800.10.9.1.4-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ilo:800.10.9.1.4-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_be8b2b439bf74624967d809ec0","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U41","U33","U37","U38","U38","U40","A41","U43","U44","A42","A43","U31","U31","A46","U48","U39","U46","A42","U46","A43","A43","A42","U47","U47","I44","I43","I42","U61","U60","A48","A47","U45","U50","U54","U54","U54","U58","U58","U59","U46","A56","A56","A55","A55","U56","U64","U65","U62","U63","U58","U63","I45","U57","U65","U65","A58","H11"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072292.exe","SHA1Sum":"339ef9d0b355a988ee5989ee7e34f0c0012b522f","SHA256Sum":"fa144e5d714b001782d7c080b17b944a84cdf59df03904c4909fa945df9f66b9","SHA512Sum":"eb548b2186c801513e96f3ce656ecf14b744632542cb5055ecfc287137c350e4ac1e3288d202f34603dcebc532783166b4c6821bdb95958d6ce86ee824b33c01"}],"ComponentSizeInKB":567,"CompsigList":["cp072292.compsig"],"FileList":["cp072292.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"Name":"cp072292.exe","SHA1Sum":"339ef9d0b355a988ee5989ee7e34f0c0012b522f","SHA256Sum":"fa144e5d714b001782d7c080b17b944a84cdf59df03904c4909fa945df9f66b9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.1.0"}],"InstallationDependency":{},"Name":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4ce3ef0c8916442f8dca8bbc3f","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-33071590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U36","U43","U41","U33","U44","A47","U40","U39","U45","U37","A46","U38","U38","U48","I43","I42","I44","U46","U46","U47","U47","U50","U61","U60","U56","A43","A42","A43","A42","A48","U50","U40","U39","U64","H10","H10","H10","H08","H08"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c566d63ca0_0HPG7-2.1_amd64.deb","SHA1Sum":"ce07b2b28977abe4de3ceeeb2a1a1f6796a23d73","SHA256Sum":"5121286818c03e9f6ec0e1eba1713e5d96611d10cf4f9c4bef320af7e532ed69","SHA512Sum":"c0c10f9dd0f4856d3f6dcf1f5cb777bb3387a66557f278c585dea0120b0d7dcdb9998da1e0db214208ff6479cab2f62a63ccc6122fbedaf11e2e766021bddbd8"}],"ComponentSizeInKB":3527,"CompsigList":["firmware-hdd-c566d63ca0_0HPG7-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/4IYRHPG7.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/CP071809.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071809.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071809.scexe"],"Name":"firmware-hdd-c566d63ca0_0HPG7-2.1_amd64.deb","SHA1Sum":"ce07b2b28977abe4de3ceeeb2a1a1f6796a23d73","SHA256Sum":"5121286818c03e9f6ec0e1eba1713e5d96611d10cf4f9c4bef320af7e532ed69","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_81d63be85ca4491fa746a01bba","SupportedDevices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG4"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG4"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG4"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG4"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG4"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9e87eecb3f-HPG4-1.1.x86_64.rpm","SHA1Sum":"949621b0c3452817b1706827c7a9739441c7fe97","SHA256Sum":"c89399ac69cb1d5ab7d4f32b9ea5c2b23fde7c48280f5144aecbd424b9074998","SHA512Sum":"631189040de65477929c4bf40ffc782b2a403d1d49c46f36375e5c444b35e7edbcb4766b1f728bddd631a1728eacf53e6ab949f69681a188ed9a747c9c32c887"}],"ComponentSizeInKB":5158,"CompsigList":["firmware-hdd-9e87eecb3f-HPG4-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/CP072124.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/M52002TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9e87eecb3f-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072124.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072124.scexe"],"Name":"firmware-hdd-9e87eecb3f-HPG4-1.1.x86_64.rpm","SHA1Sum":"949621b0c3452817b1706827c7a9739441c7fe97","SHA256Sum":"c89399ac69cb1d5ab7d4f32b9ea5c2b23fde7c48280f5144aecbd424b9074998","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWSXF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWSXH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWSXK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWUGF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWUGH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWUGK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ba6b193738c04fac9ce493b05d","SupportedDevices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-fastlinq-8.76.6.0-1.rhel9u7.x86_64.rpm","SHA1Sum":"89e675e74559d9d67fc6e29224cf225087c70979","SHA256Sum":"51f77bbf9ec8ab860447c23f1bb830eba616bb9b06fe086f3546a68823bc7dc0","SHA512Sum":"e2f7d1e3d7ee83ceb69ebc4616ecf887fbe47f59b03b0da33da4345900c40dc0e891cbc33f28eb9048b9a064d27819b354c57edb7d0b349e041c87f173d2f55f"}],"ComponentSizeInKB":17346,"CompsigList":["kmod-qlgc-fastlinq-8.76.6.0-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"Name":"kmod-qlgc-fastlinq-8.76.6.0-1.rhel9u7.x86_64.rpm","SHA1Sum":"89e675e74559d9d67fc6e29224cf225087c70979","SHA256Sum":"51f77bbf9ec8ab860447c23f1bb830eba616bb9b06fe086f3546a68823bc7dc0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.6.0-5"},{"Checksum":[{"Filename":"kmod-qlgc-fastlinq-8.76.6.0-5.rhel9u8.x86_64.rpm","SHA1Sum":"9310e8aacd0ed5782c43da46bcebeefab19386c3","SHA256Sum":"5b0633d671a5560582008e69bb3364e8c438d24f8a93f9c8382e05ad1ee171bc","SHA512Sum":"2f8f521b9369c9fc031d34e50c380b2813a5c03f35030edfd2c64699d2f8cbfb7a54eb1bd7b4bb40a5613826cf428cab91fd6d7ea40afb5c5fd6c302075d538f"}],"ComponentSizeInKB":17200,"CompsigList":["kmod-qlgc-fastlinq-8.76.6.0-5.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/qed.conf","./etc/depmod.d/qede.conf","./etc/depmod.d/qedf.conf","./etc/depmod.d/qedi.conf","./etc/depmod.d/qedr.conf","./etc/dracut.conf.d/fastlinq.conf","./lib/firmware/qed","./lib/firmware/qed/qed_init_values_zipped-8.72.1.0.bin","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-fastlinq","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-fastlinq/qed.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-fastlinq/qede.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-fastlinq/qedf.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-fastlinq/qedi.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-fastlinq/qedr.ko","./usr/share/smartupdate/kmod-qlgc-fastlinq/component.xml"],"Name":"kmod-qlgc-fastlinq-8.76.6.0-5.rhel9u8.x86_64.rpm","SHA1Sum":"9310e8aacd0ed5782c43da46bcebeefab19386c3","SHA256Sum":"5b0633d671a5560582008e69bb3364e8c438d24f8a93f9c8382e05ad1ee171bc","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd6456294"],"TypeOfChange":"1","Version":"8.76.6.0-5"}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-qlgc-fastlinq","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_58b43226cfb743ba9bc4e215af","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.31"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.31"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.31"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.31"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.31"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.31"}]},"Files":[{"Checksum":[{"Filename":"CP072520.zip","SHA1Sum":"a4428d5972216b7c65f31b7d09ff414fba460724","SHA256Sum":"59c0787d61768e0242e15e12614dc202e3f6c72517955286b1fc129547e735cf","SHA512Sum":"dbf7a0cf8df07c70e5677617020cd7a2c392076c5cde82e143a80b9203e543757cb7c1ec83af9557220aa215f5608aad1c4a8cc92d0b99e82dba449999d7896c"}],"ComponentSizeInKB":10534,"CompsigList":["CP072520.compsig"],"FileList":["/CP072520_BUILD_1.data","/CP072520.vmexe64","/CP072520.vmfile","/CP072520_VMw.zip","/CP072520.xml","/payload.json","/CP072520_VMw.zip/index.xml","/CP072520_VMw.zip/vendor-index.xml","/CP072520_VMw.zip/metadata.zip","/CP072520_VMw.zip/vib20/CP072520/HPE_bootbank_CP072520_4.21.0.1-8.0.0.20613240.vib","/CP072520_VMw.zip/metadata.zip/vendor-index.xml","/CP072520_VMw.zip/metadata.zip/vmware.xml","/CP072520_VMw.zip/metadata.zip/vibs/CP072520--8509050085311058702.xml","/CP072520_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072520_4.21.0.1-8.0.0.20613240.xml"],"Name":"CP072520.zip","SHA1Sum":"a4428d5972216b7c65f31b7d09ff414fba460724","SHA256Sum":"59c0787d61768e0242e15e12614dc202e3f6c72517955286b1fc129547e735cf","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"4.21.0","VibList":[{"Name":"CP072520","Version":"4.21.0.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9d8f1880497e43a28b16fefeb1","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A40","A41","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000800JWZJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3830-304a575a4a50","Version":"HPD5"},{"DeviceName":"VO001600JWZJQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3630-304a575a4a51","Version":"HPD5"},{"DeviceName":"VO003200JWZJR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3230-304a575a4a52","Version":"HPD5"},{"DeviceName":"VO006400JWZJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1645ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3630-3430-304a575a4a54","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP070912.zip","SHA1Sum":"cb0b1d96cb4ee6c104a5b7e84a6c29f579b08e2c","SHA256Sum":"09153868ed91b8f3b04dbc9deeace0c665f0b5c516196c237a1e4ee909644702","SHA512Sum":"a728feab8a91f2ab7105dc91b1b88ae1d7a9878bf67a981447cc3c3f98643b43f6079bc289900812c2953129be66c932f1e097028e948d2a4e7cba78b22690de"}],"ComponentSizeInKB":18029,"CompsigList":["CP070912.compsig"],"FileList":["/CP070912_BUILD_3.data","/CP070912.vmexe64","/CP070912.vmfile","/CP070912_VMw.zip","/CP070912.xml","/payload.json","/CP070912_VMw.zip/index.xml","/CP070912_VMw.zip/vendor-index.xml","/CP070912_VMw.zip/metadata.zip","/CP070912_VMw.zip/vib20/CP070912/HPE_bootbank_CP070912_HPD5.3-8.0.0.20613240.vib","/CP070912_VMw.zip/metadata.zip/vendor-index.xml","/CP070912_VMw.zip/metadata.zip/vmware.xml","/CP070912_VMw.zip/metadata.zip/vibs/CP070912-115404499603795932.xml","/CP070912_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070912_HPD5.3-8.0.0.20613240.xml"],"Name":"CP070912.zip","SHA1Sum":"cb0b1d96cb4ee6c104a5b7e84a6c29f579b08e2c","SHA256Sum":"09153868ed91b8f3b04dbc9deeace0c665f0b5c516196c237a1e4ee909644702","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3830-304a575a4a50","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3630-3430-304a575a4a54"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP070912","Version":"HPD5.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VO000800JWZJP, VO001600JWZJQ, VO003200JWZJR and VO006400JWZJT  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000800JWZJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001600JWZJQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003200JWZJR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO006400JWZJT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6a872aeea25942bb845dca350f","SupportedDevices":["562340a5-304f-3630-3430-304a575a4a54","562340a5-304f-3330-3230-304a575a4a52","562340a5-304f-3130-3630-304a575a4a51","562340a5-304f-3030-3830-304a575a4a50"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.70 (08/19/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.70 (08/19/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U46_2.70_08_19_2026.fwpkg","SHA1Sum":"f4e7e5319cee646308350511953128a6318e4e41","SHA256Sum":"3b9f14e87244bafa8fb085fe91ea88f7ee48f0fcafef695e1ea470273ed3d869","SHA512Sum":"ae96e4aeb9a79d399a1d5973707d7b69c07a23962c536d5204b2dabd645565af666d73c963b12faf2ca3f34f2af2368361616d6a3f8e5df28d3e46d5b52dec3b"}],"ComponentSizeInKB":32820,"CompsigList":[],"FileList":["payload.json","U46_2.70_08_19_2026.signed.flash","U46_2.70_08_19_2026.xml"],"Name":"U46_2.70_08_19_2026.fwpkg","SHA1Sum":"f4e7e5319cee646308350511953128a6318e4e41","SHA256Sum":"3b9f14e87244bafa8fb085fe91ea88f7ee48f0fcafef695e1ea470273ed3d869","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_620f41e25e0940ceaf19462b2f","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U46","U46","U46"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP070916.zip","SHA1Sum":"c528f709ce2d97dd63711a60701ed121fb7543d0","SHA256Sum":"5d57507e4bd335bf2748e02246063ee13b21d0a2c91211e2ca7fcd96a0ee7802","SHA512Sum":"3acabbdad3171884103f1581ee27a9cb5b2b141505ea95bf0fa078da6b9502ac5d16d16d0ef3f3e2fa385cc732bb921b825df0786a36e9ff631a40981da80dbb"}],"ComponentSizeInKB":18029,"CompsigList":["CP070916.compsig"],"FileList":["/CP070916_BUILD_3.data","/CP070916.vmexe64","/CP070916.vmfile","/CP070916_VMw.zip","/CP070916.xml","/payload.json","/CP070916_VMw.zip/index.xml","/CP070916_VMw.zip/vendor-index.xml","/CP070916_VMw.zip/metadata.zip","/CP070916_VMw.zip/vib20/CP070916/HPE_bootbank_CP070916_HPD5.3-8.0.0.20613240.vib","/CP070916_VMw.zip/metadata.zip/vendor-index.xml","/CP070916_VMw.zip/metadata.zip/vmware.xml","/CP070916_VMw.zip/metadata.zip/vibs/CP070916-7105643938265783076.xml","/CP070916_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070916_HPD5.3-8.0.0.20613240.xml"],"Name":"CP070916.zip","SHA1Sum":"c528f709ce2d97dd63711a60701ed121fb7543d0","SHA256Sum":"5d57507e4bd335bf2748e02246063ee13b21d0a2c91211e2ca7fcd96a0ee7802","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP070916","Version":"HPD5.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3e19ea5a7209484d8acd365d65","SupportedDevices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070975.zip","SHA1Sum":"0f0111a979f76a6c66383666dbaf04e28edbb8aa","SHA256Sum":"3f0e081c81171a61d995e7d38ef5ab00cb93f1151b880089bbfefdcdf17698d9","SHA512Sum":"ad58eaad34793f6bfc0dcb789d927baecf2902328d52587f73c4a7a8467399564510b691c615b815ca78f8bd38ef51c38f9a89076653fbbc809db8e04888dfb0"}],"ComponentSizeInKB":19204,"CompsigList":["CP070975.compsig"],"FileList":["/CP070975_BUILD_1.data","/CP070975.vmexe64","/CP070975.vmfile","/CP070975_VMw.zip","/CP070975.xml","/payload.json","/CP070975_VMw.zip/index.xml","/CP070975_VMw.zip/vendor-index.xml","/CP070975_VMw.zip/metadata.zip","/CP070975_VMw.zip/vib20/CP070975/HPE_bootbank_CP070975_HPG3.1-8.0.0.20613240.vib","/CP070975_VMw.zip/metadata.zip/vendor-index.xml","/CP070975_VMw.zip/metadata.zip/vmware.xml","/CP070975_VMw.zip/metadata.zip/vibs/CP070975--6893248138539057085.xml","/CP070975_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070975_HPG3.1-8.0.0.20613240.xml"],"Name":"CP070975.zip","SHA1Sum":"0f0111a979f76a6c66383666dbaf04e28edbb8aa","SHA256Sum":"3f0e081c81171a61d995e7d38ef5ab00cb93f1151b880089bbfefdcdf17698d9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070975","Version":"HPG3.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cdeedd7c8b84433196596bb951","SupportedDevices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072375.zip","SHA1Sum":"e62ca7e096c066edc007b92abc44f7f7a473f677","SHA256Sum":"395dd6eaff19ae079b00d9d43e16231884e41113d6e08e598d3d97151255bca8","SHA512Sum":"5767fe2d545c79e8767508f0e68925288f5664d8a2fc3c11abd037be24e93fd8dd8541264b5c865e5cc6e9d697b86d3818714d673267229617f0f83bf97f8cff"}],"ComponentSizeInKB":28273,"CompsigList":["CP072375.compsig"],"FileList":["/CP072375.xml","/CP072375_VMw.zip","/payload.json","/CP072375.vmexe64","/CP072375.vmfile","/CP072375_VMw.zip/index.xml","/CP072375_VMw.zip/vendor-index.xml","/CP072375_VMw.zip/metadata.zip","/CP072375_VMw.zip/vib20/CP072375/HPE_bootbank_CP072375_1.0.0-8.0.0.21495797.vib","/CP072375_VMw.zip/metadata.zip/vendor-index.xml","/CP072375_VMw.zip/metadata.zip/vmware.xml","/CP072375_VMw.zip/metadata.zip/vibs/CP072375-8912976216253258533.xml","/CP072375_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072375_1.0.0-8.0.0.21495797.xml"],"Name":"CP072375.zip","SHA1Sum":"e62ca7e096c066edc007b92abc44f7f7a473f677","SHA256Sum":"395dd6eaff19ae079b00d9d43e16231884e41113d6e08e598d3d97151255bca8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.8","VibList":[{"Name":"CP072375","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for Mellanox Open Ethernet cards","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_36b15fed590740dc90977b735c","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-24fe569b72_0HPD6-2.1_amd64.deb","SHA1Sum":"b766059b0a7f25837e23cc50615c31e813cdada5","SHA256Sum":"3d511413a2fbad5404ed5a625d139b7b44affe66c6acdb53821f2cb71cffc0c3","SHA512Sum":"94a18550ee26cb05a8b20a8326cf37a42e5cdbce5a7b79b8372c19929d903ac1bd184289f0554fd2416d4da892f50f039ae32ccb1664395863f023f0a12ca67e"}],"ComponentSizeInKB":3474,"CompsigList":["firmware-hdd-24fe569b72_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/CP071704.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/TA15SEN0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071704.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-24fe569b72-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071704.scexe"],"Name":"firmware-hdd-24fe569b72_0HPD6-2.1_amd64.deb","SHA1Sum":"b766059b0a7f25837e23cc50615c31e813cdada5","SHA256Sum":"3d511413a2fbad5404ed5a625d139b7b44affe66c6acdb53821f2cb71cffc0c3","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c770bd228a124fa68b071f4769","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp067481.zip","SHA1Sum":"3467ad2cd622f77d9a778c5a76a60b0b1422b6cb","SHA256Sum":"b69576b8f846b5fea2f9a27744160fb86ff7ad5063cb64aaf4c2bf7ee4d42f63","SHA512Sum":"007b20968e6bde7df47bc29b0c458101abb0792a3b8d82ff02f0318e4c90cd972d90d82b45adedd3db38d58d49d027075d5bf74bbe5e9082cc8c49a31ad3d226"}],"ComponentSizeInKB":120,"CompsigList":["cp067481.compsig"],"FileList":["/cp067481.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vib20/igbn/INT_bootbank_igbn_1.13.2.0-1OEM.900.0.24580437.vib","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vmware.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vibs/igbn-831206253632276349.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/bulletins/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.xml"],"Name":"cp067481.zip","SHA1Sum":"3467ad2cd622f77d9a778c5a76a60b0b1422b6cb","SHA256Sum":"b69576b8f846b5fea2f9a27744160fb86ff7ad5063cb64aaf4c2bf7ee4d42f63","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2025.11.00","VibList":[{"Name":"igbn","Version":"1.13.2.0-1OEM.900.0.24580437"}]}],"InstallationDependency":{},"Name":"HPE Intel igbn Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_eb551c6b6b314fbfa83789debb","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","A58","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Files":[{"Checksum":[{"Filename":"CP072200.zip","SHA1Sum":"77562c6f3854e68f19f6bb3b863edefa883d1f0c","SHA256Sum":"34a05eb7e912901014329086b51810e163875e282e763c8815040de039488c1e","SHA512Sum":"3d29b51b56b5cdc37acd573ec6200d50737350611a227a88d556f1c8e08f6e6764c6994c8b5a41c405878ee42df3c43a6d74d25166bca9dd13a72dd2e9d86830"}],"ComponentSizeInKB":8143,"CompsigList":["CP072200.compsig"],"FileList":["/CP072200_BUILD_1.data","/CP072200.vmcfg","/CP072200.vmexe64","/CP072200.vmfile","/CP072200_VMw.zip","/CP072200.xml","/payload.json","/CP072200_VMw.zip/index.xml","/CP072200_VMw.zip/vendor-index.xml","/CP072200_VMw.zip/metadata.zip","/CP072200_VMw.zip/vib20/CP072200/HPE_bootbank_CP072200_6.00.1-8.0.0.20613240.vib","/CP072200_VMw.zip/metadata.zip/vendor-index.xml","/CP072200_VMw.zip/metadata.zip/vmware.xml","/CP072200_VMw.zip/metadata.zip/vibs/CP072200--195979244729356799.xml","/CP072200_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072200_6.00.1-8.0.0.20613240.xml"],"Name":"CP072200.zip","SHA1Sum":"77562c6f3854e68f19f6bb3b863edefa883d1f0c","SHA256Sum":"34a05eb7e912901014329086b51810e163875e282e763c8815040de039488c1e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00","VibList":[{"Name":"CP072200","Version":"6.00.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0a93984f97a24bb9be208e1bdf","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60","U46"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072272.exe","SHA1Sum":"9be49851630030e2384d719101fb57fac4556fa7","SHA256Sum":"3296e8727562f6c2b68843a8bcd1b9e4f43f38c00f24eb25d2373da479f1feeb","SHA512Sum":"f370ebfa7c9953285861adc742e580c697c49c02d2c6826c15d42773e5301cc460a1403a70f9b784e76f44d459aa0ffe8ed4efbd1985dabb32699fd6816e62f8"}],"ComponentSizeInKB":1534,"CompsigList":["cp072272.compsig"],"FileList":["cp072272.xml","cpqsetup.exe","cp_data.xml","i40eb68.cat","i40eb68.din","i40eb68.inf","i40eb68.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp072272.exe","SHA1Sum":"9be49851630030e2384d719101fb57fac4556fa7","SHA256Sum":"3296e8727562f6c2b68843a8bcd1b9e4f43f38c00f24eb25d2373da479f1feeb","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520"],"TypeOfChange":"1","Version":"1.25.114.0"}],"InstallationDependency":{},"Name":"HPE Intel i40eb Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40eb68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4022f66dba744f6ba3c95b7acc","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-iavf-4.13.35-1.rhel10u1.x86_64.rpm","SHA1Sum":"b8d9875b44235a0fcdc89eba1fb2556bcd9d96c5","SHA256Sum":"76281384517b01b3d5eb8c981434edbe1226d7fb1f3e8d845d221e854624366c","SHA512Sum":"17e74533b06e92b91a981310fc665d874971b05e2da605a379b20bf72ba6a32bf8d052fc7069f40f9f38d66281b62abab0a5c9905b8acccc5d9f8536c3b4c154"}],"ComponentSizeInKB":232,"CompsigList":["kmod-iavf-4.13.35-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-iavf.conf","./etc/modprobe.d/iavf.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/iavf/iavf.ko","./usr/share/doc/kmod-iavf","./usr/share/doc/kmod-iavf/COPYING","./usr/share/doc/kmod-iavf/README","./usr/share/doc/kmod-iavf/pci.updates","./usr/share/man/man7/iavf.7.gz","./usr/share/smartupdate/kmod-iavf/component.xml"],"Name":"kmod-iavf-4.13.35-1.rhel10u1.x86_64.rpm","SHA1Sum":"b8d9875b44235a0fcdc89eba1fb2556bcd9d96c5","SHA256Sum":"76281384517b01b3d5eb8c981434edbe1226d7fb1f3e8d845d221e854624366c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec52bf8d0b"],"TypeOfChange":"1","Version":"4.13.35-1"},{"Checksum":[{"Filename":"kmod-iavf-4.13.35-1.rhel10u2.x86_64.rpm","SHA1Sum":"40e1a78ac7cc0ca0e19fe06d6d3cae3790738983","SHA256Sum":"85e52f4d2e497b54e1c5e9b70cb4469a7c85da7e302e830d07ed99dde1ff226b","SHA512Sum":"9f8852a8d2f4b07a0f96126312c996dbd24d76b4eb54211eb89f264e2e5c01fece41e51de0f927d72b084c37dc78f1e0eea50083e8679a9edccb23e1e47ebe15"}],"ComponentSizeInKB":232,"CompsigList":["kmod-iavf-4.13.35-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-iavf.conf","./etc/modprobe.d/iavf.conf","./lib/modules/6.12.0-211.7.1.el10_2.x86_64/extra/iavf/iavf.ko","./usr/share/doc/kmod-iavf","./usr/share/doc/kmod-iavf/COPYING","./usr/share/doc/kmod-iavf/README","./usr/share/doc/kmod-iavf/pci.updates","./usr/share/man/man7/iavf.7.gz","./usr/share/smartupdate/kmod-iavf/component.xml"],"Name":"kmod-iavf-4.13.35-1.rhel10u2.x86_64.rpm","SHA1Sum":"40e1a78ac7cc0ca0e19fe06d6d3cae3790738983","SHA256Sum":"85e52f4d2e497b54e1c5e9b70cb4469a7c85da7e302e830d07ed99dde1ff226b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec52bf8d0b"],"TypeOfChange":"1","Version":"4.13.35-1"}],"InstallationDependency":{},"Name":"HPE Intel iavf Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-iavf","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-iavf","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3918c3b8e67947428b4d71114a","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-15ff8086000c","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"storcli-007.3811.0300-1.noarch.rpm","SHA1Sum":"078ddf9dae1aa33dc5bb142b77d2ea6ce1b98895","SHA256Sum":"170131153c62e798ba7054af14aadd383a0248e3094ad5ea0ff3506986073cf3","SHA512Sum":"b45c15ccd54c4db6c0121f04228f91a568c840dcf81a8b16ee9d314f1d548745834d3f811b8322d63eb8f9135a6e52f53d8ce99f73c381c55b23f795bc8e3cce"}],"ComponentSizeInKB":2813,"CompsigList":["storcli-007.3811.0300-1.noarch.compsig"],"FileList":["./opt/MegaRAID/storcli/storcli","./opt/MegaRAID/storcli/storcli64","./usr/share/smartupdate/storcli/component.xml"],"Name":"storcli-007.3811.0300-1.noarch.rpm","SHA1Sum":"078ddf9dae1aa33dc5bb142b77d2ea6ce1b98895","SHA256Sum":"170131153c62e798ba7054af14aadd383a0248e3094ad5ea0ff3506986073cf3","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"007.3811.0300"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for Linux 64-bit (for Gen10P and Gen11 Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"storcli","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a39a8a9e3aa149f89cefbd87d5","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","A72","U71","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-smartpqi-2.1.40-020.rhel9u6.x86_64.rpm","SHA1Sum":"cdefdfd9dd6b84c7fb27d44bd8e16ec029ac894d","SHA256Sum":"342d50525c1774429799a9bf6e32f1ca7932ce4f2a3f433444f1986a437164f8","SHA512Sum":"b4be3472a04e92bd5af177828f83612be1429d84c7f8065990ea29f0bea1d93d66889598f66b7b5e18360619e6b2bee8c101059bc86aa7b6404317c2d58c774b"}],"ComponentSizeInKB":105,"CompsigList":["kmod-smartpqi-2.1.40-020.rhel9u6.x86_64.compsig"],"FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/5.14.0-570.12.1.el9_6.x86_64","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/smartpqi","./lib/modules/5.14.0-570.12.1.el9_6.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/26","./usr/lib/.build-id/26/e9067561782d0a333267c894be04e55a12adae","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"Name":"kmod-smartpqi-2.1.40-020.rhel9u6.x86_64.rpm","SHA1Sum":"cdefdfd9dd6b84c7fb27d44bd8e16ec029ac894d","SHA256Sum":"342d50525c1774429799a9bf6e32f1ca7932ce4f2a3f433444f1986a437164f8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.40-020"},{"Checksum":[{"Filename":"kmod-smartpqi-2.1.40-020.rhel9u7.x86_64.rpm","SHA1Sum":"7f222a06553851eda39d9fbae82ba34ee437cf73","SHA256Sum":"ec1e4fe7ceb338243fdb40416ae2d81cb5e04020788766d5aa95d0378906fd9d","SHA512Sum":"ee6de5b6c3e3243a25fa9fd18d02449389c14dbc4c38cf020896cff0b136784b983783d00039d1d1767e65c6cbadb516f7b2246577943fcaf32d8339f3e136f2"}],"ComponentSizeInKB":112,"CompsigList":["kmod-smartpqi-2.1.40-020.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/smartpqi.conf","./etc/dracut.conf.d/smartpqi.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/smartpqi","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/smartpqi/smartpqi.ko","./usr/lib/.build-id","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/e0e8e0426e1533fa14b7726280b4f746c2f833","./usr/share/smartupdate/kmod-smartpqi/component.xml"],"Name":"kmod-smartpqi-2.1.40-020.rhel9u7.x86_64.rpm","SHA1Sum":"7f222a06553851eda39d9fbae82ba34ee437cf73","SHA256Sum":"ec1e4fe7ceb338243fdb40416ae2d81cb5e04020788766d5aa95d0378906fd9d","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec91247558"],"TypeOfChange":"1","Version":"2.1.40-020"}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for Red Hat Enterprise Linux 9 (64-bit)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-smartpqi","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d90f018f760941ecab340cd568","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","A43","HPE Apollo 2000 Gen10 Plus System","A42","U46","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","A43","I44","U60","U61","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","U71","U68","U68","U72","U68","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900382","Version":"8.23"},{"DeviceName":"HPE_SR_Gen10_SR308i_Gen11","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_SR_Gen10_8.23_A.HPb","InstallDurationSec":400,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f15900383","Version":"8.23"}]},"Files":[{"Checksum":[{"Filename":"HPE_SR_Gen10_8.23_A.fwpkg","SHA1Sum":"0bbae64c779f1c3f5a1adbccdf4f23285292ffef","SHA256Sum":"71e9da6a6a8663c26e5a1376fdee476c7664f7a66cc5f27694ba58afba92eaf0","SHA512Sum":"8552a5e518756d5f8b9f7438453f8b842f94522ed4bff78183d9b1d6affab26517e2dc0af0ff9524ece0166834c042c02c7ce798202333dcc42f49c4c0c0effc"}],"ComponentSizeInKB":11835,"CompsigList":[],"FileList":["HPE_SR_Gen10_8.23_A.HPb","HPE_SR_Gen10_8.23_A.xml","payload.json"],"Name":"HPE_SR_Gen10_8.23_A.fwpkg","SHA1Sum":"0bbae64c779f1c3f5a1adbccdf4f23285292ffef","SHA256Sum":"71e9da6a6a8663c26e5a1376fdee476c7664f7a66cc5f27694ba58afba92eaf0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f15900383"],"TypeOfChange":"1","Version":"8.23"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"MinimumActiveVersion":"5.61","Name":"Firmware Package  - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P204i-c, P416ie-m and P816i-a SR Gen10 and SR308i-o,SR308i-p Gen11 controllers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":400,"RebootRequired":"yes","SWKeys":[{"Name":"03831590","SWKeyExpectedPath":"firmware"},{"Name":"03821590","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"1100103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7b32c1640d704503b329228d12","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","10.0"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A56","A56","A55","A55","U58","U54","U54","U54","U63","U58","U58","U59","U63","U34","U34","A42","U46","U30","A42","U46","U32","A43","A43","A43","U31","U31","U36","U41","U33","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U50","U39","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U61","U60","U46","U57","U65","U65","U62","U64","U43","U44","U50","U71","U71","U68","U68","A66","A66","U68","U72"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ef93133161-HPD4-4.1.x86_64.rpm","SHA1Sum":"f47c954b8b2fb2d1182df2756cfd01fd6d737749","SHA256Sum":"f8867e559a63ee939b9634c764c4402fd9a63827694c92e48b90965f9707279f","SHA512Sum":"c325adf0188cfa19b068f8e5bf8c0cb9be17cb2123c937602a1f58f4e3cf33d00a37182371a82b64b4e1536f36c8536c2daecda9f5a3b73571db4d28454b35e1"}],"ComponentSizeInKB":5394,"CompsigList":["firmware-hdd-ef93133161-HPD4-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/CP068854.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/WBCPssssASFD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ef93133161-HPD4-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068854.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068854.scexe"],"Name":"firmware-hdd-ef93133161-HPD4-4.1.x86_64.rpm","SHA1Sum":"f47c954b8b2fb2d1182df2756cfd01fd6d737749","SHA256Sum":"f8867e559a63ee939b9634c764c4402fd9a63827694c92e48b90965f9707279f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_728eef229104453693c5a71e67","SupportedDevices":["4d2340a5-304f-3630-3430-304a57554742","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3130-3630-304a57554656","452340a5-304f-3130-3630-304a57554745","4d2340a5-304f-3030-3830-304a57554655","452340a5-304f-3030-3830-304a57554744","4d2340a5-304f-3030-3430-304a57554654","452340a5-304f-3030-3430-304a57554743"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ae6b41e855_0HPD8-2.1_amd64.deb","SHA1Sum":"09e388af557cc23397f53a5ccc515c929c008b2b","SHA256Sum":"c3cd8762d60b06e00dc3a21160e35c01501febf4908dd57d7c5dbf2d38feb7a2","SHA512Sum":"df3068436d427846c111b84113ab75cc377a4e68effc969ff76a391cb210e49c4b2464bc95aa93d75f0f9445a95d51eb4ac30a88bfdfa1983daa8ff0920b71db"}],"ComponentSizeInKB":4472,"CompsigList":["firmware-hdd-ae6b41e855_0HPD8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/CP071781.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/SCIMARRNESD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071781.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071781.scexe"],"Name":"firmware-hdd-ae6b41e855_0HPD8-2.1_amd64.deb","SHA1Sum":"09e388af557cc23397f53a5ccc515c929c008b2b","SHA256Sum":"c3cd8762d60b06e00dc3a21160e35c01501febf4908dd57d7c5dbf2d38feb7a2","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e4343e7341204d8faedd7a7588","SupportedDevices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL6CBA0HPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp073200.exe","SHA1Sum":"27f2d2771d95f5db6ec9e7b1fd86e71d387461c3","SHA256Sum":"cee37327b75c4bb2bad09212b019cc326239bd8cde52b679a70a8f8da877260a","SHA512Sum":"1acf2c86e6f4d863e6a7f8fded76bcb8a3af1071beff32893656e26ae9f5c7c3bb2dbac40abb715d6588867a11cb427deeb3869907be9c52b2301bad26070670"}],"ComponentSizeInKB":4458,"CompsigList":["cp073200.compsig"],"FileList":["cp073200.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WVL6CBA0HPD4.rel"],"Name":"cp073200.exe","SHA1Sum":"27f2d2771d95f5db6ec9e7b1fd86e71d387461c3","SHA256Sum":"cee37327b75c4bb2bad09212b019cc326239bd8cde52b679a70a8f8da877260a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JWKGN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_723197e200d949c08076e0e471","SupportedDevices":["4d2340a5-3042-3630-3030-304a574b474e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 661SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./XXV710DA2_8p30_CFGID12p0_OEMGEN_J65979.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-158b15900253","Version":"8.30"}]},"Files":[{"Checksum":[{"Filename":"firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1.x86_64.rpm","SHA1Sum":"e1ac47651ca19b1bd3094a56f0c368cceba7ad27","SHA256Sum":"32affc2266eac4735a156ca97f3fd3324fd7f42687ca5f43e40035136f406aa0","SHA512Sum":"a9c6cede2d61e0e866ba3d59b002a22e6f9b7cd8aa801c62bc6f770ce678e306e0da62a8e36c24ae00d039ffe46f464445f5c958b44a2590b0f2af4b263237cf"}],"ComponentSizeInKB":9685,"CompsigList":["firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/661SFP.cfg","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/CP071036.xml","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/FVL_25G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/XXV710DA2_9p20_CFGID12p0_OEMGEN.bin","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/iSCSI.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/iv.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/nvmupdatew64e","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/payload_version.txt","./usr/lib/x86_64-linux-gnu/firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071036.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071036.scexe"],"Name":"firmware-intel-661sfp28-e2a1937d845d42ec9b6ec589ebce44d3-9.20-1.1.x86_64.rpm","SHA1Sum":"e1ac47651ca19b1bd3094a56f0c368cceba7ad27","SHA256Sum":"32affc2266eac4735a156ca97f3fd3324fd7f42687ca5f43e40035136f406aa0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-158b15900253"],"TypeOfChange":"1","Version":"9.20"}],"InstallationDependency":{},"Name":"HPE Edgeline 661SFP28 NIC Firmware Pack for Linux","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"XXV710_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a48ea6f356ad447b82d413492a","SupportedDevices":["a6b1a447-382a-5a4f-8086-158b15900253"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","7.0","20.4","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","H10","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Samsung-PM9A3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Samsung_PM9A3_GPM9A3SAHPK4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304b584c5846","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"Samsung_PM9A3_GPM9A3SAHPK4.fwpkg","SHA1Sum":"2c23039e2f867225671fab0fcc1b9a982089fae1","SHA256Sum":"34e915bce71521266b3218cf37d2e1c1c0356161eaf17d09daa806633be4da48","SHA512Sum":"0258b498eb36187a81244b63daeb9e4d1517671799ad2a1abbdf11e34d1e449de38e5fa83af80924da72dccd7e99e7ea9884bfe942085bb22d799a37ad744171"}],"ComponentSizeInKB":3091,"CompsigList":[],"FileList":["payload.json","Samsung_PM9A3_GPM9A3SAHPK4.HPb","Samsung_PM9A3_GPM9A3SAHPK4.xml"],"Name":"Samsung_PM9A3_GPM9A3SAHPK4.fwpkg","SHA1Sum":"2c23039e2f867225671fab0fcc1b9a982089fae1","SHA256Sum":"34e915bce71521266b3218cf37d2e1c1c0356161eaf17d09daa806633be4da48","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3052-3030-3438-304b584c5846"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  VR000480KXLXF","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VR000480KXLXF","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f8a034bd867140ceab209744ed","SupportedDevices":["562340a5-3052-3030-3438-304b584c5846"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"cp068625.exe","SHA1Sum":"0bcbcd48753624ff53a395a5d159853e30363e3e","SHA256Sum":"4695f7465eec97b497cd6c7b1f01749178ac5829a5b6faeffb87c7590b3dc111","SHA512Sum":"95dd710bffc24b25aea6b3324a706580f973d82215c584ff3f122b950795816dd5868f9502e0a4afd551b08a024243cdb5ecefda9c5ac7f5f817ca10e458c49a"}],"ComponentSizeInKB":5335,"CompsigList":["cp068625.compsig"],"FileList":["cp068625.xml","cpqsetup.exe","KPE60X1GHPK4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068625.exe","SHA1Sum":"0bcbcd48753624ff53a395a5d159853e30363e3e","SHA256Sum":"4695f7465eec97b497cd6c7b1f01749178ac5829a5b6faeffb87c7590b3dc111","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_292d8b1e06bf4f8796fc78a8ed","SupportedDevices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 661SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./XXV710DA2_8p30_CFGID12p0_OEMGEN_J65979.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-158b15900253","Version":"8.30"}]},"Files":[{"Checksum":[{"Filename":"cp070454.exe","SHA1Sum":"db4993be7b53c1f6191828fd80fac24bb7cb72de","SHA256Sum":"af44cbc044c00bea0b358ae2167d9cef325abde880e27868699950e43919016e","SHA512Sum":"c621b47955c65540cde8ba80eb1306aa6a3d42e9f06186a075d4d3cc39e52f3360abc989ff8b64e5e6b4a5cecefed49e76b8475f302192aea3574abbf2f1445a"}],"ComponentSizeInKB":9654,"CompsigList":["cp070454.compsig"],"FileList":["661SFP.cfg","BootIMG.FLB","cp070454.xml","cpqsetup.exe","FVL_25G_Adapter_VPD_MAP.txt","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","iSCSI.txt","iv.txt","nvmupdatew64e.exe","payload.json","payload_version.txt","XXV710DA2_9p20_CFGID12p0_OEMGEN.bin"],"Name":"cp070454.exe","SHA1Sum":"db4993be7b53c1f6191828fd80fac24bb7cb72de","SHA256Sum":"af44cbc044c00bea0b358ae2167d9cef325abde880e27868699950e43919016e","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-158b15900253"],"TypeOfChange":"1","Version":"9.20"}],"InstallationDependency":{},"Name":"HPE Edgeline 661SFP28 NIC Firmware Pack for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"XXV710_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c28f2857d33846b1a33081f250","SupportedDevices":["a6b1a447-382a-5a4f-8086-158b15900253"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","H10","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072871.zip","SHA1Sum":"1d91f7e313175329934ff4cc0eef249279c04651","SHA256Sum":"74439f47043cf4794104232aa3f85282f3f5a5b2af86ebb44609355f3da573cd","SHA512Sum":"23120babb6c5441fda3990738c81ad1c2f17162246714bb14c8f3df8a64f48786b043cc581040a26db9625035ea3a5c442223b26b42afb50f9ec773b2826a595"}],"ComponentSizeInKB":6374,"CompsigList":["cp072871.compsig"],"FileList":["/cp072871.xml","/sutComponent_800.6.9.0.32-0-signed_component.zip","/sutComponent_800.6.9.0.32-0-signed_component.zip/index.xml","/sutComponent_800.6.9.0.32-0-signed_component.zip/vendor-index.xml","/sutComponent_800.6.9.0.32-0-signed_component.zip/metadata.zip","/sutComponent_800.6.9.0.32-0-signed_component.zip/vib20/sut/HPE_bootbank_sut_800.6.9.0.32-1OEM.802.0.0.22380479.vib","/sutComponent_800.6.9.0.32-0-signed_component.zip/metadata.zip/vendor-index.xml","/sutComponent_800.6.9.0.32-0-signed_component.zip/metadata.zip/vmware.xml","/sutComponent_800.6.9.0.32-0-signed_component.zip/metadata.zip/vibs/sut-5052667152260837848.xml","/sutComponent_800.6.9.0.32-0-signed_component.zip/metadata.zip/bulletins/sutComponent_800.6.9.0.32-0.xml","/sutComponent_800.6.9.0.32-0-signed_component.zip/metadata.zip/configSchemas/sut-800.6.9.0.32-1OEM.802.0.0.22380479-schema.json"],"Name":"cp072871.zip","SHA1Sum":"1d91f7e313175329934ff4cc0eef249279c04651","SHA256Sum":"74439f47043cf4794104232aa3f85282f3f5a5b2af86ebb44609355f3da573cd","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.2"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf4d60f54"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"sut","Version":"800.6.9.0.32-1OEM.802.0.0.22380479"}]}],"InstallationDependency":{},"Name":"Integrated Smart Update Tools 6.9.0 for ESXi 8.0, ESXi 9.0 and ESXi 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":150,"RebootRequired":"yes","SWKeys":[{"Name":"sutComponent:800.6.9.0.32-0","SWKeyExpectedPath":"software.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e2f8d735d6954ff09a17bca887","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["HP Smart Update Tools (HP SUT)","A55","A55","A56","A56","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","A46","U47","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","A42","U56","U61","U60","U64","U46","I43","I45","I44","I42","U65","U65","U58","U59","U57","U63","U62","U63","U58","U58","U54","U54","U54","U71","U69","U69","U71","U68","U72","U68","U68","HPE ProLiant DL380m Gen12","R13","U70","I46","U72","U77","H10","U65","H11","A58","U66","U68","A66","A66","U71","A72","HPE ProLiant Compute DL384VR Gen13","HPE ProLiant ML30 Gen13 Server","A55","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"CP070974.zip","SHA1Sum":"355f0fdcd64b48fd684cf5c0d2a1a8590669e71c","SHA256Sum":"39c7f30ffe64a656a2575341d9c6c3d5c98b21c0203c87170c30a218e64b1199","SHA512Sum":"e244a4cdcaa9701467a09b447780e316f4e063088342d7b90f725bd22543ef231f18fae74d58420c174cb09227f09dacd83498375beb209aa16469e025ae7e5f"}],"ComponentSizeInKB":19826,"CompsigList":["CP070974.compsig"],"FileList":["/CP070974_BUILD_1.data","/CP070974.vmexe64","/CP070974.vmfile","/CP070974_VMw.zip","/CP070974.xml","/payload.json","/CP070974_VMw.zip/index.xml","/CP070974_VMw.zip/vendor-index.xml","/CP070974_VMw.zip/metadata.zip","/CP070974_VMw.zip/vib20/CP070974/HPE_bootbank_CP070974_HPD6.1-8.0.0.20613240.vib","/CP070974_VMw.zip/metadata.zip/vendor-index.xml","/CP070974_VMw.zip/metadata.zip/vmware.xml","/CP070974_VMw.zip/metadata.zip/vibs/CP070974--1594029885113675755.xml","/CP070974_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070974_HPD6.1-8.0.0.20613240.xml"],"Name":"CP070974.zip","SHA1Sum":"355f0fdcd64b48fd684cf5c0d2a1a8590669e71c","SHA256Sum":"39c7f30ffe64a656a2575341d9c6c3d5c98b21c0203c87170c30a218e64b1199","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6","VibList":[{"Name":"CP070974","Version":"HPD6.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_409411b90dd3417d9971976ae9","SupportedDevices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3610B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186e25083e","Version":"6.00"},{"DeviceName":"HPE D3710B 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-6.00-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18227c1658","Version":"6.00"}]},"Files":[{"Checksum":[{"Filename":"cp072207.exe","SHA1Sum":"79dc00cc4789616ceb11430105ea95cf14a14af1","SHA256Sum":"78e2e0d5a6397d538b4d5a7b9b06d739b05b2278e997bfd57325d9dc81ab40f2","SHA512Sum":"5a2eb681519a1567444f4887d9003fa4e229b6185b7ea14599a85d598fba0412d690818cf4dd9b985fa112c5eb32cacc1d3d215b3dbabebf7b7e6312da2a912b"}],"ComponentSizeInKB":5026,"CompsigList":["cp072207.compsig"],"FileList":["Config.xml","cp072207.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-6.00-build-000.bin","VDUFlash.dll"],"Name":"cp072207.exe","SHA1Sum":"79dc00cc4789616ceb11430105ea95cf14a14af1","SHA256Sum":"78e2e0d5a6397d538b4d5a7b9b06d739b05b2278e997bfd57325d9dc81ab40f2","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd186e25083e","b99dfb74-f0bc-464f-b418-cd18227c1658"],"TypeOfChange":"1","Version":"6.00"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3610B/D3710B 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3610B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710B","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e7b5b08f30ae4968ad47cf785c","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072276.exe","SHA1Sum":"9ce7d7341be07c77a671ef496a06f1a20f3146f1","SHA256Sum":"fd786df777613d358c9b443f32fcf226e3628a347e1d3b18ff231c0bf6229872","SHA512Sum":"c5c24d8f4012567be70541da01a475e02b2824e153c8cb9da6a2fd6176a9e14115807b64c345e6ebf3778533759ebeb41077ca28fce30d5b6304b1c1a14940c0"}],"ComponentSizeInKB":1405,"CompsigList":["cp072276.compsig"],"FileList":["cp072276.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"Name":"cp072276.exe","SHA1Sum":"9ce7d7341be07c77a671ef496a06f1a20f3146f1","SHA256Sum":"fd786df777613d358c9b443f32fcf226e3628a347e1d3b18ff231c0bf6229872","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.19.113.0"}],"InstallationDependency":{},"Name":"HPE Intel iavf Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fdfd757a18fe4f85b4fab1de50","SupportedDevices":["a6b1a447-382a-5a4f-8086-37CD15900000","a6b1a447-382a-5a4f-8086-37cd80860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-154c103c0000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068747.exe","SHA1Sum":"cce44c2241988e373511e6996b4850ffebc641bd","SHA256Sum":"88c03aed91155b0f886a5e1ff73a73101b213591ae5d5ed0c0f1968489fbf4e4","SHA512Sum":"657e215ac79880fb1345069cc32f6ddeec4897d913a4c4412990b2e5f286582ccb7aa92415ba5d33cea3845e72c01385bfb3ce448cd006f523071520b4cf67c2"}],"ComponentSizeInKB":4557,"CompsigList":["cp068747.compsig"],"FileList":["cp068747.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEBsssATFG3.rel"],"Name":"cp068747.exe","SHA1Sum":"cce44c2241988e373511e6996b4850ffebc641bd","SHA256Sum":"88c03aed91155b0f886a5e1ff73a73101b213591ae5d5ed0c0f1968489fbf4e4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWUDA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2dbde1482fdc4b03bbfab4b3b3","SupportedDevices":["4d2340a5-3042-3431-3030-304757554441"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A48_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071581.exe","SHA1Sum":"1c6ab55ae82c217f649f562cd27112c51147fcb5","SHA256Sum":"ecfd2a269d4b57b39cf2c0c2bd02108755d4c5eac2be3ac8bd88ecbf2a015abf","SHA512Sum":"02b3e5f6daae1e011a5a54bf31d2646407e49fdbe1736cd663fb881b6a3e6f742d6c01656aa12135bbceef1efc0dcaffcd0a5755a646079787b1d2a6c528a173"}],"ComponentSizeInKB":33434,"CompsigList":["cp071581_part1.compsig","cp071581_part2.compsig"],"FileList":["A48_4.04_04_02_2026.signed.flash","cp071581.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071581.exe","SHA1Sum":"1c6ab55ae82c217f649f562cd27112c51147fcb5","SHA256Sum":"ecfd2a269d4b57b39cf2c0c2bd02108755d4c5eac2be3ac8bd88ecbf2a015abf","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6230481f66494d54afb86d2b24","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"42fc70be-bb87-4bdb-8e7c-db1c9af52957","Devices":{"Device":[{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000242","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000221","Version":"2.1.0"}]},"Files":[{"Checksum":[{"Filename":"cp072094.exe","SHA1Sum":"003de43c383523a813cca136277699e78fb430b0","SHA256Sum":"3103210bae68e2efa1febb1341d7cbde8b4a4f5c8c4cd4622127a3e18a19ecc3","SHA512Sum":"bd90798e377b3549b6ced2aaa75bedd164d65d59b74a36a2d556429584ec6f50509614fc7510f14807b790127d6d2776c4c2b85b51ec5498489b6da77226e618"}],"ComponentSizeInKB":905,"CompsigList":["cp072094.compsig"],"FileList":["ACCE_2.1.0s.bin","cp072094.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp072094.exe","SHA1Sum":"003de43c383523a813cca136277699e78fb430b0","SHA256Sum":"3103210bae68e2efa1febb1341d7cbde8b4a4f5c8c4cd4622127a3e18a19ecc3","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000242","00000000-0000-0000-0000-00000000023a","00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"2.1.0"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 -  HPE Edgeline Chassis Controller Firmware","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"ACCE","SWKeyExpectedPath":"firmware:ACC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b4e3a5d725374940aea4439eb7","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["HPE Edgeline EL8000t Converged Edge System","FTP","H11","H08","H10","H11"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-1a541ed00d_0GPK6-2.1_amd64.deb","SHA1Sum":"1af762ee6f3356a20c05fddb4140c3242e6b32bb","SHA256Sum":"c93452f08753d156ce25ec9efafab571a1e158490a6be4133f0741a978d37c89","SHA512Sum":"7b9598af03ed7926305c74b5e1ddd21bba8b9ad98ae72fe066c50c5728a571be8a2497e2279d21ee84c305c1db516aa84f1a683c46313341f3788f6859dadfb7"}],"ComponentSizeInKB":5031,"CompsigList":["firmware-hdd-1a541ed00d_0GPK6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/CP071773.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/KACM6ALFGPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071773.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071773.scexe"],"Name":"firmware-hdd-1a541ed00d_0GPK6-2.1_amd64.deb","SHA1Sum":"1af762ee6f3356a20c05fddb4140c3242e6b32bb","SHA256Sum":"c93452f08753d156ce25ec9efafab571a1e158490a6be4133f0741a978d37c89","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0b60d101ae594e83a0300f19a7","SupportedDevices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000800KWWFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3830-304b57574645","Version":"HPK4"},{"DeviceName":"MK001600KWWFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3630-304b57574646","Version":"HPK4"},{"DeviceName":"MK003200KWWFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3230-304b57574648","Version":"HPK4"},{"DeviceName":"MK006400KWWFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3630-3430-304b5757464b","Version":"HPK4"},{"DeviceName":"VK000960KWWFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304b5757464c","Version":"HPK4"},{"DeviceName":"VK001920KWWFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304b5757464e","Version":"HPK4"},{"DeviceName":"VK003840KWWFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304b57574650","Version":"HPK4"},{"DeviceName":"VK007680KWWFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KPE60X1GHPK4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-304b57574651","Version":"HPK4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-54addf5312-HPK4-3.1.x86_64.rpm","SHA1Sum":"fbb983282fb7826e440b017a2ade3149f0cb330a","SHA256Sum":"a2d0a41d8933e4bfc6c4effa8dd15dac4c49700f837e4caf2da9cfdc2da7f7c8","SHA512Sum":"27dcc5bf13c9f71f3be42216fc4f165e45fcb5cb10b2e043329cac5252acde9290ea4ed1c9b40d382e36e8172c5299a3e3e8bd4e0ab4b3d9420cdd8ccd1b4667"}],"ComponentSizeInKB":7216,"CompsigList":["firmware-hdd-54addf5312-HPK4-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/CP068906.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/KPE60X1GHPK4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-54addf5312-HPK4-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068906.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068906.scexe"],"Name":"firmware-hdd-54addf5312-HPK4-3.1.x86_64.rpm","SHA1Sum":"fbb983282fb7826e440b017a2ade3149f0cb330a","SHA256Sum":"a2d0a41d8933e4bfc6c4effa8dd15dac4c49700f837e4caf2da9cfdc2da7f7c8","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3830-304b57574645","4d2340a5-304b-3130-3630-304b57574646","4d2340a5-304b-3330-3230-304b57574648","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3030-3936-304b5757464c","562340a5-304b-3130-3932-304b5757464e","562340a5-304b-3330-3834-304b57574650","562340a5-304b-3730-3638-304b57574651"],"TypeOfChange":"1","Version":"HPK4"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - MK000800KWWFE, MK001600KWWFF, MK003200KWWFH, MK006400KWWFK, VK000960KWWFL, VK001920KWWFN, VK003840KWWFP and VK007680KWWFQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000800KWWFE","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK001600KWWFF","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK003200KWWFH","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MK006400KWWFK","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK000960KWWFL","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK001920KWWFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK003840KWWFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VK007680KWWFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7ebf0ab82df74654bb70a9bc31","SupportedDevices":["562340a5-304b-3730-3638-304b57574651","4d2340a5-304b-3630-3430-304b5757464b","562340a5-304b-3330-3834-304b57574650","4d2340a5-304b-3330-3230-304b57574648","562340a5-304b-3130-3932-304b5757464e","4d2340a5-304b-3130-3630-304b57574646","562340a5-304b-3030-3936-304b5757464c","002340a5-4b4d-3030-3830-304b57574645"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"238.1.169000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"238.1.169000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"238.1.169000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"238.1.169000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"238.1.169000"}]},"Files":[{"Checksum":[{"Filename":"cp072712.exe","SHA1Sum":"c8c338409b10542995184b37b5b7b1f03d1a1a40","SHA256Sum":"71ff740f935f47d1cd28b7b28f4122ac5b24907935918c47573aa211614f6f31","SHA512Sum":"67209c7a634cd5fd56bcf699af6628e73a8e56c0b11b965c3f97a28e8926b4cfbe7966e19d62c862f6f020837b3750c0379f210222e953279985da2ce75767ac"}],"ComponentSizeInKB":10282,"CompsigList":["cp072712.compsig"],"FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp072712.xml","cpqsetup.exe","FW/","FW/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","FW/535T-2x10-14E4-16D8-1590-020C.PKG","FW/536I-2x10-14E4-16D6-1590-0230.pkg","FW/537SFP-2x10-14E4-16D7-1590-02C3.pkg","FW/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","FW/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","FW/631SFP28-2x25-14E4-16D7-1590-020E.PKG","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp072712.exe","SHA1Sum":"c8c338409b10542995184b37b5b7b1f03d1a1a40","SHA256Sum":"71ff740f935f47d1cd28b7b28f4122ac5b24907935918c47573aa211614f6f31","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"5.4.8.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_981272a47da9437b849236f683","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03030201","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWWQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757575155","Version":"HPG8"},{"DeviceName":"MB006000GWWQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNETG8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304757575154","Version":"HPG8"}]},"Files":[{"Checksum":[{"Filename":"CP070943.zip","SHA1Sum":"535ab5414ac218884cbf9873978ef54f1efd655a","SHA256Sum":"bbbf608125dbd56d41308e8ff8b233ace6968fc8600ab0738b7f9682428a4a27","SHA512Sum":"456fee72b9cc0d305ab69b9ac68aad21dfd5ef9313ecaaede4586625089ed69ea076026f9f816eab7dfb3f1c455b7ec469dc4569bf577c05805524ccbb968bf0"}],"ComponentSizeInKB":19165,"CompsigList":["CP070943.compsig"],"FileList":["/CP070943_BUILD_6.data","/CP070943.vmexe64","/CP070943.vmfile","/CP070943_VMw.zip","/CP070943.xml","/payload.json","/CP070943_VMw.zip/index.xml","/CP070943_VMw.zip/vendor-index.xml","/CP070943_VMw.zip/metadata.zip","/CP070943_VMw.zip/vib20/CP070943/HPE_bootbank_CP070943_HPG8.6-8.0.0.20613240.vib","/CP070943_VMw.zip/metadata.zip/vendor-index.xml","/CP070943_VMw.zip/metadata.zip/vmware.xml","/CP070943_VMw.zip/metadata.zip/vibs/CP070943--985892147586158893.xml","/CP070943_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070943_HPG8.6-8.0.0.20613240.xml"],"Name":"CP070943.zip","SHA1Sum":"535ab5414ac218884cbf9873978ef54f1efd655a","SHA256Sum":"bbbf608125dbd56d41308e8ff8b233ace6968fc8600ab0738b7f9682428a4a27","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"TypeOfChange":"1","Version":"HPG8","VibList":[{"Name":"CP070943","Version":"HPG8.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWWQU and MB006000GWWQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWWQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB006000GWWQT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_44cf669ea6404c639e893adc61","SupportedDevices":["4d2340a5-3042-3830-3030-304757575155","4d2340a5-3042-3630-3030-304757575154"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPS7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-951aefd63e_0MPK7825Q-2.1_amd64.deb","SHA1Sum":"d2dda7eb38a8ad9825c1a6ddbebd65fd292dd5ab","SHA256Sum":"608897f606848e37bf76918b0db3cbbfd98c5b4ed2e7a5dc4782a504bf32498e","SHA512Sum":"c8a6e86b0c318851b863f4e914196136767b9ef81bcf302f4b0e64490eca19a4fad58b08aed2bfee933ff38f95434145a59f9a1669c69c5382ee20db7fe31e96"}],"ComponentSizeInKB":6733,"CompsigList":["firmware-hdd-951aefd63e_0MPK7825Q-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/CP071808.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/MPS7825Q.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071808.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-951aefd63e-MPK7825Q-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071808.scexe"],"Name":"firmware-hdd-951aefd63e_0MPK7825Q-2.1_amd64.deb","SHA1Sum":"d2dda7eb38a8ad9825c1a6ddbebd65fd292dd5ab","SHA256Sum":"608897f606848e37bf76918b0db3cbbfd98c5b4ed2e7a5dc4782a504bf32498e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) -MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3 and MZXLR7T6HALA-000H3  Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_696664c5e09d42098393ad8af5","SupportedDevices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL8WBA0HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-82894b9e0a-HPG4-2.1.x86_64.rpm","SHA1Sum":"9de9f51f9a24d9a09e9e7c360b0c0fedd90205a7","SHA256Sum":"5ad76277a88b15cb0122b781562b89b31647eabfa3928692c2b67f1f668d7870","SHA512Sum":"8d2de042ac796c841491f1718c725ca56ba8cca887bbcd9b29ecc9789c30d8f3e2504e39d13a847fb22d4158bbb6e194e46880d75ea6dd49d328c3fa1a1c1820"}],"ComponentSizeInKB":6182,"CompsigList":["firmware-hdd-82894b9e0a-HPG4-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/CP073299.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/WVL8WBA0HPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-82894b9e0a-HPG4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073299.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073299.scexe"],"Name":"firmware-hdd-82894b9e0a-HPG4-2.1.x86_64.rpm","SHA1Sum":"9de9f51f9a24d9a09e9e7c360b0c0fedd90205a7","SHA256Sum":"5ad76277a88b15cb0122b781562b89b31647eabfa3928692c2b67f1f668d7870","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000GWRTC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2da994de5e124c74be35a571ea","SupportedDevices":["4d2340a5-3042-3830-3030-304757525443"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Files":[{"Checksum":[{"Filename":"CP070951.zip","SHA1Sum":"fdc7c6436cc01ff6e22386a739f38f5df17c1197","SHA256Sum":"9cd69dff272fd77cbfaaf4e2f814b1c3cfc7b6d44e255f3803d476e5684e36d4","SHA512Sum":"ac5bf8b06d5ee5627d0686fa89154d2aeec00e6b52c959216acbde895788964038a43809c9115fd2f1792fec8bbf670626aed2c8c700dc1d2db842388f5c5c60"}],"ComponentSizeInKB":19116,"CompsigList":["CP070951.compsig"],"FileList":["/CP070951_BUILD_2.data","/CP070951.vmexe64","/CP070951.vmfile","/CP070951_VMw.zip","/CP070951.xml","/payload.json","/CP070951_VMw.zip/index.xml","/CP070951_VMw.zip/vendor-index.xml","/CP070951_VMw.zip/metadata.zip","/CP070951_VMw.zip/vib20/CP070951/HPE_bootbank_CP070951_HPDC.2-8.0.0.20613240.vib","/CP070951_VMw.zip/metadata.zip/vendor-index.xml","/CP070951_VMw.zip/metadata.zip/vmware.xml","/CP070951_VMw.zip/metadata.zip/vibs/CP070951--7149723854572770878.xml","/CP070951_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070951_HPDC.2-8.0.0.20613240.xml"],"Name":"CP070951.zip","SHA1Sum":"fdc7c6436cc01ff6e22386a739f38f5df17c1197","SHA256Sum":"9cd69dff272fd77cbfaaf4e2f814b1c3cfc7b6d44e255f3803d476e5684e36d4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC","VibList":[{"Name":"CP070951","Version":"HPDC.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JWXKH Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_399805b170d2473b88e5eaba95","SupportedDevices":["4d2340a5-3042-3631-3030-304a57584b48"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U47_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073097.exe","SHA1Sum":"9ec61c409f4754410dd2301da4514be4b22e76eb","SHA256Sum":"df16b81570eab14787cb4cc449b3c0842389a793a9116d7fa5c32030dd630003","SHA512Sum":"18e34a4393e8fef63187dcef52a3235545f023068ec39774e4099dc33fe96e90804e26d0d366b4c259357a7b24b53dfa55cee8037d4e4d4e965768caa9c6a828"}],"ComponentSizeInKB":33439,"CompsigList":["cp073097_part1.compsig","cp073097_part2.compsig"],"FileList":["cp073097.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U47_2.70_08_19_2026.signed.flash"],"Name":"cp073097.exe","SHA1Sum":"9ec61c409f4754410dd2301da4514be4b22e76eb","SHA256Sum":"df16b81570eab14787cb4cc449b3c0842389a793a9116d7fa5c32030dd630003","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47)","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ac89fb7fb6d944df817eb8d67a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U47","U47","FTP"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"iavf-kmp-default-4.13.35_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"37b2d7552857e3831c8b2d10dccf00adea6e9ad1","SHA256Sum":"b446023a5bd927416781490b1d78fc4a757ce79f123857306746b5361bd04a9a","SHA512Sum":"1a467cdc4c6b58ea991e96d0f164233fadcd0fc2da9bfe20fe12d6a2f2460338a081116739134cc359719374a97750ea94545cb89e8161ca81383c74779d8ce4"}],"ComponentSizeInKB":223,"CompsigList":["iavf-kmp-default-4.13.35_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/iavf.ko","./usr/share/doc/packages/iavf-kmp-default","./usr/share/doc/packages/iavf-kmp-default/COPYING","./usr/share/doc/packages/iavf-kmp-default/README","./usr/share/man/man7/iavf.7.gz","./usr/share/pci.ids.d/pci.ids.iavf-kmp-4.13.35","./usr/share/smartupdate/iavf-kmp-default/component.xml"],"Name":"iavf-kmp-default-4.13.35_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"37b2d7552857e3831c8b2d10dccf00adea6e9ad1","SHA256Sum":"b446023a5bd927416781490b1d78fc4a757ce79f123857306746b5361bd04a9a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec99229626"],"TypeOfChange":"1","Version":"4.13.35-1"}],"InstallationDependency":{},"Name":"HPE Intel iavf Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"iavf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_27ec8c782c104bd58f9c2d7a50","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-15ff8086000c","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-12d380860007"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"cp068731.exe","SHA1Sum":"b5d626da7d6e17b54a903a95414f2f985d831aed","SHA256Sum":"d407186cef9820b83cc17ef223acb56e90fb3d94f3d2870e24665d0b9a01354f","SHA512Sum":"f4473bd4f50f5681018b71469b2f632edb7b6400dc4e8bc1f619bad36db31d674dee4caf545cef5e52054bd75dc74f0cb9dc8e1bd442e506e4ebe974b8737079"}],"ComponentSizeInKB":4212,"CompsigList":["cp068731.compsig"],"FileList":["cp068731.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNESD8.rel","setup.dll"],"Name":"cp068731.exe","SHA1Sum":"b5d626da7d6e17b54a903a95414f2f985d831aed","SHA256Sum":"d407186cef9820b83cc17ef223acb56e90fb3d94f3d2870e24665d0b9a01354f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000JWWQP and MB006000JWWQN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8aa7071f46d84a058e94d59287","SupportedDevices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-7a1edae8e7-HPG1-8.1.x86_64.rpm","SHA1Sum":"17858aa2a8590fdb2faab13c5c487c65ba32cd83","SHA256Sum":"c1c1d7c0069241cdbc33ce9c8057fb30775d2539a718443aa87b960e994cc00a","SHA512Sum":"bf0d7dd6f56f8153ae5125145a3cc39a3d4d58a1cf724ab85cc3628db746f1636bf3683c6c399c66673ad877be69003b08f694ed230ce24ca71dec816e2997d5"}],"ComponentSizeInKB":5878,"CompsigList":["firmware-hdd-7a1edae8e7-HPG1-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/CP068804.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/SHPEEVANSTG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068804.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068804.scexe"],"Name":"firmware-hdd-7a1edae8e7-HPG1-8.1.x86_64.rpm","SHA1Sum":"17858aa2a8590fdb2faab13c5c487c65ba32cd83","SHA256Sum":"c1c1d7c0069241cdbc33ce9c8057fb30775d2539a718443aa87b960e994cc00a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f8863e8510334a8fb6bd7e4316","SupportedDevices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel10u1.x86_64.rpm","SHA1Sum":"38de33bbfa9e3531fa5b9c11c2df8d5cc6c1ebb4","SHA256Sum":"03b9ff5c69105fb44bd4ab696559ace0b1168bcac9cc12b5853959d9d3e26daa","SHA512Sum":"435e10725938d0294e7372d29f890975e6cc892aca46467373ee69fb930d5df0571d1a058561ca807351125221bdea2ab25902353c7a6142f3c9a83ad0f11b6d"}],"ComponentSizeInKB":79,"CompsigList":["kmod-kernel-mft-mlnx-4.36.0-147.1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/kernel-mft-mlnx","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/lib/.build-id","./usr/lib/.build-id/dc","./usr/lib/.build-id/dc/56d9087076c17dba1b6619d764bb304de7b43e","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/bf648a8419210c90603ea1bd80200bd9170677","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"Name":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel10u1.x86_64.rpm","SHA1Sum":"38de33bbfa9e3531fa5b9c11c2df8d5cc6c1ebb4","SHA256Sum":"03b9ff5c69105fb44bd4ab696559ace0b1168bcac9cc12b5853959d9d3e26daa","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"mft-4.36.0-147.rhel10u1.x86_64.rpm","SHA1Sum":"a62902960f2e92500f24b481e40c46c6537806cf","SHA256Sum":"139d525659bca95268dc2045a8812b9a1ef33d820127911b4dd2a449dbbc0fde","SHA512Sum":"44728181dd4c72d93d236ce86cf2f14f28ff8903d41e8891bf455ef53e472d2e0132ce543fa63acdf1e25b943683b9c3b8a95c30b0c51aef08e3998d9f6a7cb6"}],"ComponentSizeInKB":29822,"CompsigList":["mft-4.36.0-147.rhel10u1.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.rhel10u1.x86_64.rpm","SHA1Sum":"a62902960f2e92500f24b481e40c46c6537806cf","SHA256Sum":"139d525659bca95268dc2045a8812b9a1ef33d820127911b4dd2a449dbbc0fde","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 10 Update 1 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8f82b73bec6445349f439556e4","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-102115b30237"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","02020001","03020101","03030201"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"MRStorageAdministrator-008.018.011.000-00.rhel10.x86_64.rpm","SHA1Sum":"0cdda248b49c9e7736b71cd01c7a820756394634","SHA256Sum":"1b5535121f39e2e1f4e6b68568e9a698d3068d9abeab55f4c7811737732888c0","SHA512Sum":"2ba0e170790dbd3beb014e46ca505627188c45717ec7bb7ce773b7457d952d36249a2d50c66248d9b34ed45dfc25281f7c44d12539bae96133c289a0914c094d"}],"ComponentSizeInKB":29273,"CompsigList":["MRStorageAdministrator-008.018.011.000-00.rhel10.x86_64.compsig"],"FileList":["./etc/init.d/LsiSASH","./opt/HPEMRSA/LSIStorageAuthority","./opt/HPEMRSA/LSIStorageAuthority/bin","./opt/HPEMRSA/LSIStorageAuthority/bin/LSA","./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so.4","./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib8.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibir-3.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so","./opt/HPEMRSA/LSIStorageAuthority/bin/lsistorageauthority.service","./opt/HPEMRSA/LSIStorageAuthority/bin/mrsstorageauthority.service","./opt/HPEMRSA/LSIStorageAuthority/bin/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer","./opt/HPEMRSA/LSIStorageAuthority/bin/storelib8conf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconfit.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/temp","./opt/HPEMRSA/LSIStorageAuthority/conf","./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf","./opt/HPEMRSA/LSIStorageAuthority/conf/languages","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr8_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_errors_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode8.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs","./opt/HPEMRSA/LSIStorageAuthority/logs","./opt/HPEMRSA/LSIStorageAuthority/plugins","./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/report","./opt/HPEMRSA/LSIStorageAuthority/server","./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win","./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types","./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/docs","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru","./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/README","./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/html","./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-Chg-Personality1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-LSA7_set_adjust_task_rate.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure1-InstallShieldWizardDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure2-PortConfigurationSettingsDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure3-DestinationFolderDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure4-ConfigureRangeOfEventsToGenerateAlertNotifications.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA8_set_task_priority.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_NVMe_Thermal_Poll_Interval.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_alert_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_manage_power_save_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_writecache_policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_changing_behavior_modes.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-EnableUnmapFeatureDuringVolumeCreation.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-FW-Activation-Status.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Factory-Defaults.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Restore-Factory-Defaults.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Viewing-Protected-Drive-Groups.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-device-reporting-order-hpe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ChangeDrive-Security.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure23-EnableOrDisableTheScsiUnmapFeature.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ManagePCIe-Storage-Interface2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_UpdateFW_2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_profile3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_tape_drive_7.4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/MSM_IR_OH_icon_Tape_drive.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/Replace-a-Missing-Drive.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/config-login-no-login-localhost-remote-access.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-available-drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume-add-phy-drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-expand-online-capacity-volume.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-drives.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-modify-physical-function.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function-info.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-protected-arrays.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-drives.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-show-protected-arrays.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-drive-power-control.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-drive-power-control.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-expand-online-capacity-vd.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-lsa-spin-down.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-managing-power-save-settings.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-op-phy-functions.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-auto-assign-policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-device-reporting-order.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-help-auto-assign-policy.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-make-jbod-choices.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-manage-sid-ownership.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-physical-functions-operations.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-spin-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_function_profile_mngmt.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_manage_sid_ownership.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties_dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-hpe-nvram-clear.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-nvme-thermal-poll-interval.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr8-nvme-drive-format.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v10550932.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036741.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036763.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036906.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11169464.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049673.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049745.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12382402.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13070587.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13292421.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v26717125.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v8285855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9157473.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9506612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9508081.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9894102.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/97AB61D67CC8D4791C6CB34B01AEDD99.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/53EF515E4B68F4375CDAB62B8BF5DF72.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/59AE9E2C0EDDF3AAB8FA2CAAE04CA10B.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/2EE840FAFCB91D1EAD07D1F6BA3F09A2.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/B607368818C162A84762061F2C356C99.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/5F36DB58B87376D92AE07C107220CAFC.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/logs","./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log","./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log","./opt/HPEMRSA/LSIStorageAuthority/server/nginx","./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/start.log","./opt/HPEMRSA/LSIStorageAuthority/server/temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9","./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh","./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh","./usr/lib/.build-id","./usr/lib/.build-id/00","./usr/lib/.build-id/00/6409b5707928d043f68afe4991697e50b79671","./usr/lib/.build-id/00/6409b5707928d043f68afe4991697e50b79671.1","./usr/lib/.build-id/0d","./usr/lib/.build-id/0d/8aa3aa399ec364adf42205be9468b804983669","./usr/lib/.build-id/1e","./usr/lib/.build-id/1e/4ab9e5ac3873f1e9e96ccb8d456aa9b8c8421e","./usr/lib/.build-id/1e/d82579e740ef91bd7925299955ef4fcb9da651","./usr/lib/.build-id/1e/d82579e740ef91bd7925299955ef4fcb9da651.1","./usr/lib/.build-id/22","./usr/lib/.build-id/22/6d68df44845b0c7dc5ef410f3f668e54d98d4a","./usr/lib/.build-id/29","./usr/lib/.build-id/29/5ebed48961c1f0be76d28e65e4ad918a48d7a9","./usr/lib/.build-id/33","./usr/lib/.build-id/33/458cfa214cc81fc145bd5f6907efd7e0aafd1b","./usr/lib/.build-id/3d","./usr/lib/.build-id/3d/38c62e56eb18f90588f0c0671b2649c0f19429","./usr/lib/.build-id/3e","./usr/lib/.build-id/3e/92220a201aa84dee762fab7a95ab79efe15379","./usr/lib/.build-id/3e/92220a201aa84dee762fab7a95ab79efe15379.1","./usr/lib/.build-id/69","./usr/lib/.build-id/69/634d282a5acf1996cfd0836ddf65a032d681b9","./usr/lib/.build-id/69/634d282a5acf1996cfd0836ddf65a032d681b9.1","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/4ddf43f85d29be91e0ed25d4ad7b1254fab378","./usr/lib/.build-id/6c/4ddf43f85d29be91e0ed25d4ad7b1254fab378.1","./usr/lib/.build-id/7d","./usr/lib/.build-id/7d/1d76522d03644c92e51daf661ea0cb87e3ac60","./usr/lib/.build-id/7d/1d76522d03644c92e51daf661ea0cb87e3ac60.1","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/12e9baa47f8f05096c26585d622e8399db8b42","./usr/lib/.build-id/8c/12e9baa47f8f05096c26585d622e8399db8b42.1","./usr/lib/.build-id/93","./usr/lib/.build-id/93/7ff067ea0ac8b14a9d72809610cf202fba9bcb","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/196810755f0eef617025b491d1a9a794eb6de4","./usr/lib/.build-id/a1/196810755f0eef617025b491d1a9a794eb6de4.1","./usr/lib/.build-id/a2","./usr/lib/.build-id/a2/0980fd24b5096e329b22ef027bce82656c8a3b","./usr/lib/.build-id/a9","./usr/lib/.build-id/a9/c802296b807a1d057ab3d0a55348bf07e14390","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/283a31fc643caa7e0c8ac92a4b38efa6b20b24","./usr/lib/.build-id/c3","./usr/lib/.build-id/c3/60ad11822954dfc9c8dfe8a8d78966318c0a90","./usr/lib/.build-id/cf","./usr/lib/.build-id/cf/c4093ce682b4099d4294bc3232dc9218cf4425","./usr/lib/.build-id/cf/c4093ce682b4099d4294bc3232dc9218cf4425.1","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/8f1a74a48ef91989b2522a2059876facfdf263","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/8de4be87dc2c1a42d5d3bde990aa9bc5f99d66","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/dce544ac29ba70ee7deffb7c53adc4d0c45ba3","./usr/share/smartupdate/MRStorageAdministrator/component.xml"],"Name":"MRStorageAdministrator-008.018.011.000-00.rhel10.x86_64.rpm","SHA1Sum":"0cdda248b49c9e7736b71cd01c7a820756394634","SHA256Sum":"1b5535121f39e2e1f4e6b68568e9a698d3068d9abeab55f4c7811737732888c0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"TypeOfChange":"1","Version":"8.18.11.0"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator for RHEL10 (HPE MRSA for MR Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"MRStorageAdministrator","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_81f2f117928541698f4d9a2ce9","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448","a6b1a447-382a-5a4f-1000-00b315900453"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U54","U54","U58","U63","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.4008.0"}]},"Files":[{"Checksum":[{"Filename":"CP072304.zip","SHA1Sum":"9ba52954b7930bb6bb342f06c38044a052b5b20d","SHA256Sum":"de544019e6abdff3ccd7630407fc2793d81e6c5b0cf14f03e41960a367942d4a","SHA512Sum":"df0076d92e454ceaea983e42c4dc2a26eb2dce832dc355aeb3a32a7bfc606b9ee906384445126b7dbfd59f4f719645f127baab269cb0da13c9c96349b1a3b768"}],"ComponentSizeInKB":23873,"CompsigList":["CP072304.compsig"],"FileList":["/CP072304_BUILD_8.data","/CP072304.vmexe64","/CP072304.vmfile","/CP072304_VMw.zip","/CP072304.xml","/payload.json","/CP072304_VMw.zip/index.xml","/CP072304_VMw.zip/vendor-index.xml","/CP072304_VMw.zip/metadata.zip","/CP072304_VMw.zip/vib20/CP072304/HPE_bootbank_CP072304_3.31.0.8-8.0.0.20613240.vib","/CP072304_VMw.zip/metadata.zip/vendor-index.xml","/CP072304_VMw.zip/metadata.zip/vmware.xml","/CP072304_VMw.zip/metadata.zip/vibs/CP072304-2024059307294975662.xml","/CP072304_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072304_3.31.0.8-8.0.0.20613240.xml"],"Name":"CP072304.zip","SHA1Sum":"9ba52954b7930bb6bb342f06c38044a052b5b20d","SHA256Sum":"de544019e6abdff3ccd7630407fc2793d81e6c5b0cf14f03e41960a367942d4a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"3.31.0","VibList":[{"Name":"CP072304","Version":"3.31.0.8-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Intel Online Firmware Upgrade Utility VMware for HPE ProLiant Gen9 and Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_393e2f6d7ca34ce29ffffe487f","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-1521103c337f"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","U36","U39","U45","O43","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL8WBA0HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"cp073298.exe","SHA1Sum":"b0755a2342752917210adea3e8af00ca4ca033f6","SHA256Sum":"01b64f1eb88b87344fa281881a204cb48608385edb8a9992d30ee6761d74a412","SHA512Sum":"be47447c1d486ad28e6652e4c944428047e0ef3f73f442bf23a33a2125794496fcc8e727fff1a2d6dfa9f6cbefdc8e8443fcf15c3685227956d07d4d37bad714"}],"ComponentSizeInKB":4351,"CompsigList":["cp073298.compsig"],"FileList":["cp073298.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WVL8WBA0HPG4.rel"],"Name":"cp073298.exe","SHA1Sum":"b0755a2342752917210adea3e8af00ca4ca033f6","SHA256Sum":"01b64f1eb88b87344fa281881a204cb48608385edb8a9992d30ee6761d74a412","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB008000GWRTC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e602fd44d8d64b41980dce5415","SupportedDevices":["4d2340a5-3042-3830-3030-304757525443"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u2.x86_64.rpm","SHA1Sum":"1740569f471134c462ab83ec9dc5fb3442d4c141","SHA256Sum":"aaf007fd929ad56600bec9ed51b4786f2af0e8f8511c79db983862445fd83fa0","SHA512Sum":"f0f985a0a93443f262825de5c70917902343264a4e99187e2cf5b729003927d508a76d40ae9e9875c2d85923690e1d473f0f74713ed22968b8a68947b652d7a7"}],"ComponentSizeInKB":1995,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u2.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/02","./usr/lib/.build-id/02/e44353fa850ffd9aa7bb85810373e293fb4e7f","./usr/lib/.build-id/12","./usr/lib/.build-id/12/06539ee0904cf829de0309f963cca7d87987e2","./usr/lib/.build-id/18","./usr/lib/.build-id/18/69a48c0f71c97ea9549a621a335b65695e853e","./usr/lib/.build-id/1a","./usr/lib/.build-id/1a/2e82d2b820a1a913fd5d95ce5761e2fb3e4176","./usr/lib/.build-id/1c","./usr/lib/.build-id/1c/35ea925090feeabe0e2a5d163f9fe655b04bff","./usr/lib/.build-id/2c","./usr/lib/.build-id/2c/440f5567574df7af8855587bc46b58689a074f","./usr/lib/.build-id/2c/966d6358b5acecc83d9890c87d24c2af1b634d","./usr/lib/.build-id/5e","./usr/lib/.build-id/5e/385d753f92aef1a637ec7878741b42d0080d58","./usr/lib/.build-id/80","./usr/lib/.build-id/80/da383987f7cc582a9fcb9fe23434464f856d70","./usr/lib/.build-id/9d","./usr/lib/.build-id/9d/4e8f94e5990b582d39daafc25c0db54042cc23","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/5e99478d4c4c043de8f4aeac9dfc819531fd88","./usr/lib/.build-id/a7","./usr/lib/.build-id/a7/b0c1ae3cfa518477a57da1c88a73f6a4b23e8c","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/22acac57daafbbfcd5b01b060812511e16904c","./usr/lib/.build-id/b9","./usr/lib/.build-id/b9/80b11215e601a3e8f1b6db28731435ac013754","./usr/lib/.build-id/bc","./usr/lib/.build-id/bc/b44092db5ea572f5267751014c44525dccdc82","./usr/lib/.build-id/ca","./usr/lib/.build-id/ca/6d55c7d5898beb5eab4d6491aeeb3a9b0ff501","./usr/lib/.build-id/d9","./usr/lib/.build-id/d9/17c74cf52fadfb67b2eed0c095eeefb92fa17b","./usr/lib/.build-id/dc","./usr/lib/.build-id/dc/54705c1e468f44ffef135c4e81e43c795a0b57","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/c7c2b1ba487b6299289ada024edc44132b730b","./usr/lib/.build-id/ed","./usr/lib/.build-id/ed/d9abe05bf048dc95e705d1cede5b6e63d0299f","./usr/lib/.build-id/f2","./usr/lib/.build-id/f2/ad50a9a16131c71b4751c781ee1b9baf220d83","./usr/lib/.build-id/f6","./usr/lib/.build-id/f6/5def2aa440070a9c216922fce9fcb2da27d652","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/mlnx-ofa_kernel","./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/perftest","./usr/share/doc/perftest/COPYING","./usr/share/doc/perftest/README","./usr/share/doc/perftest/runme","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u2.x86_64.rpm","SHA1Sum":"1740569f471134c462ab83ec9dc5fb3442d4c141","SHA256Sum":"aaf007fd929ad56600bec9ed51b4786f2af0e8f8511c79db983862445fd83fa0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u2.x86_64.rpm","SHA1Sum":"ae78e0ad4a3cea03a8180d3ef31126fedf6792fb","SHA256Sum":"bed6324c9eb13a8fb2ace61e968764a4e4c7d9d5068fde86b88ce45ef2236f80","SHA512Sum":"1f0300dd4ef52eaa422c695557477dbdd4eda091b08df678af1dd58c474508d37853e2d70e6fe6b2b5da2c48467ebbb59de6fe8bd68d3301dfb966717d48c095"}],"ComponentSizeInKB":2766,"CompsigList":["kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/lib/.build-id","./usr/lib/.build-id/06","./usr/lib/.build-id/06/6454e03ae0514fac741df14a4bc4ffb2801147","./usr/lib/.build-id/0a","./usr/lib/.build-id/0a/4a94c3b4de3e997a69011820b5c9d4053f2ad7","./usr/lib/.build-id/15","./usr/lib/.build-id/15/d703d62cbbd4e2820b7e43d72930efcd85f7a9","./usr/lib/.build-id/1f","./usr/lib/.build-id/1f/5cd29fd23cd6c6726af2ac735157502ba6f7a2","./usr/lib/.build-id/20","./usr/lib/.build-id/20/a544f2c62cd305a272d07cb12a4058cb17cc9c","./usr/lib/.build-id/26","./usr/lib/.build-id/26/938f6bd95026be5c2d482abb94692d566f95b0","./usr/lib/.build-id/2a","./usr/lib/.build-id/2a/16596591ea13c9b4e4bd263fa37ea58ecb3429","./usr/lib/.build-id/32","./usr/lib/.build-id/32/28303957e913e9f7e4da8d6f7763795ee92879","./usr/lib/.build-id/37","./usr/lib/.build-id/37/5d097b48092f435aa9025eff9b93b6888c2442","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/90c7a9036bf9a0f77a385887b58adb6915596f","./usr/lib/.build-id/3b","./usr/lib/.build-id/3b/7d18a172fc48ef6377ff742dccb72472ffb807","./usr/lib/.build-id/4b","./usr/lib/.build-id/4b/acbaa34ce8b6c5b3664441c7d5bd23a1943f93","./usr/lib/.build-id/4e","./usr/lib/.build-id/4e/595375cf68fd142090882011b0090ad18010b5","./usr/lib/.build-id/52","./usr/lib/.build-id/52/f71b78cd9318a2919c0fa70cb2f94db96cc38c","./usr/lib/.build-id/55","./usr/lib/.build-id/55/94b1cf220e46e12288006a08580d2134ad40fe","./usr/lib/.build-id/5b","./usr/lib/.build-id/5b/0494c8c0dcf4e87d4f706c94a6f83f614c142b","./usr/lib/.build-id/5c","./usr/lib/.build-id/5c/0948744717fbed5b8079ff7fe94319a0838c47","./usr/lib/.build-id/5f","./usr/lib/.build-id/5f/b90a986dc064f981678d3f31ab87d39e26df10","./usr/lib/.build-id/62","./usr/lib/.build-id/62/6aba4b3d67b519ab96c0f79146102263479590","./usr/lib/.build-id/62/fb5f29c801d3ffd564a90b33cacf31b59c0f7c","./usr/lib/.build-id/64","./usr/lib/.build-id/64/50460cee9b33f4cf6fdce5469c7abb25a458cb","./usr/lib/.build-id/6a","./usr/lib/.build-id/6a/d3be36ccaabe4f1774914f78834d735579e078","./usr/lib/.build-id/6f","./usr/lib/.build-id/6f/b734af9b6bc3b4a6a4bfd4d7e1492b3fa6a926","./usr/lib/.build-id/7f","./usr/lib/.build-id/7f/82a1ac22a03daa4f14fcf90c000b2719458ce0","./usr/lib/.build-id/89","./usr/lib/.build-id/89/527646a93cc188f927fdb933651b4c13eeb77d","./usr/lib/.build-id/89/ae8cd102de82b60999ffaaccb85bd347c8b83a","./usr/lib/.build-id/8b","./usr/lib/.build-id/8b/403d1fa776f4143538624ebe51e1db0b2f9dba","./usr/lib/.build-id/9d","./usr/lib/.build-id/9d/9c783838a14b74c7c3f68dc2b4671f887308bc","./usr/lib/.build-id/a3","./usr/lib/.build-id/a3/3907fc72d96e29145fe9f9eb33350c23c67037","./usr/lib/.build-id/b5","./usr/lib/.build-id/b5/af6a4c030692aae8b1690e4725cdb8d9c24490","./usr/lib/.build-id/b7","./usr/lib/.build-id/b7/c6666999ece56c1ce326d967f6114673a36ab8","./usr/lib/.build-id/b8","./usr/lib/.build-id/b8/5382f519888770f5b1efd1c3bc510312026ba7","./usr/lib/.build-id/bf","./usr/lib/.build-id/bf/84a68a7573b643407fab6414c1d6d48b1df679","./usr/lib/.build-id/c9","./usr/lib/.build-id/c9/9420c21ba9e70a67dac2654174760f46bb145d","./usr/lib/.build-id/d4","./usr/lib/.build-id/d4/eb5bf4239f25adbaf27478e6fc68d62700a6e5","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/a14d6fcb691ba51f1829c78e6ffb10fe2d3de0","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/434fcce9679ed5293e96307053af637f5808ac","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/0546c43cd6e740a7efea0c49e5534ee9fe0014","./usr/lib/.build-id/ef","./usr/lib/.build-id/ef/34659f71d902658b6c13291e698085e9e041dd","./usr/lib/.build-id/f8","./usr/lib/.build-id/f8/25d63578bbde9fa7ed954506fbce2125db61dd","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"Name":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u2.x86_64.rpm","SHA1Sum":"ae78e0ad4a3cea03a8180d3ef31126fedf6792fb","SHA256Sum":"bed6324c9eb13a8fb2ace61e968764a4e4c7d9d5068fde86b88ce45ef2236f80","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"Name":"Linux","Value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"Name":"Linux","Value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"Name":"Linux","Value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"Name":"Linux","Value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 10 Update 2 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8457e49b96d649779011852620","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U69","U69","U70","A72","U68","U68","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLHCCBA0HPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp072248.exe","SHA1Sum":"5cef178eb7081809aa985537adfd8d66062ee548","SHA256Sum":"234af8aed5b34928a6fbb1d6263c7ad2027df037c3defd592cce43b7818cecce","SHA512Sum":"6954af10f920ed98c949bdd97cc3d0ccb54e66dae07db686e7c01196b60954bef80cb0fd84e99b17e59cfb856c578ec12191b86a1e31ec317ee60df643b9e411"}],"ComponentSizeInKB":4325,"CompsigList":["cp072248.compsig"],"FileList":["cp072248.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLHCCBA0HPD5.rel"],"Name":"cp072248.exe","SHA1Sum":"5cef178eb7081809aa985537adfd8d66062ee548","SHA256Sum":"234af8aed5b34928a6fbb1d6263c7ad2027df037c3defd592cce43b7818cecce","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JWDFD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2183e35c540a4158ae2c29d455","SupportedDevices":["4d2340a5-3042-3231-3030-304a57444644"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15b30068","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"192da1f6675ae43b202c36917bae35383bb2ccac","SHA256Sum":"de818b35e4d202af32e1f8df0d0172412a023a5867f2f39d50ba4a42bedd1c3d","SHA512Sum":"7cb986c91a849d48a135255a17573747f234e1432034e1bfd987edc4d6de13abc905559442d9ec3262c6a3368c6f16f436b43c182499654a09c5f1871112432d"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.signed","20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653105A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"192da1f6675ae43b202c36917bae35383bb2ccac","SHA256Sum":"de818b35e4d202af32e1f8df0d0172412a023a5867f2f39d50ba4a42bedd1c3d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 MCX653105A-HDAT Adapter : HPE part numbers P23664-B21 and P23664-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653105A-HDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_78cb53d697014ce796cce57d53","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15b30068"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072294.exe","SHA1Sum":"b9ec83849c8e42130d52c335c2632ed2d492d0aa","SHA256Sum":"55e4ae14c098b45d03384662a2a80bc8848a9f37541e155f6d8884d4d7a331fe","SHA512Sum":"5c0cf8f91493e5c31c74ac3b12c805ec1e39d298a4944caba25cfc90da14bfdd04b6b2f65001ae2a00c66e4b7e9ad540c068f11f89a54430cdfe6581ebcf05ea"}],"ComponentSizeInKB":602,"CompsigList":["cp072294.compsig"],"FileList":["cp072294.xml","cpqsetup.exe","installer.dll","pnp/","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"Name":"cp072294.exe","SHA1Sum":"b9ec83849c8e42130d52c335c2632ed2d492d0aa","SHA256Sum":"55e4ae14c098b45d03384662a2a80bc8848a9f37541e155f6d8884d4d7a331fe","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19006.8299"}],"InstallationDependency":{},"Name":"Identifiers for Intel Xeon Scalable Processors (First and Second Generation) for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_139acb881eb2411c8512277544","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","U32","U31","U31","U41","U33","U40","U39","I43","I42","03020101","02020001","U39","U40","I41","U36","U45","U37","U38","U38","H08","H08","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a27c95663d_0HPK6-2.1_amd64.deb","SHA1Sum":"e873e4959db56ee481b773981471f172e79213ca","SHA256Sum":"8cc9d49395be9eb28151ee3346d04a1a76e8ee5ad87f926b6b8e253d550e8e6d","SHA512Sum":"a4dc38960982702c4f65aecf1904c52ff0b232a669dfdbdc0c913b2ae91100e56274b9df0b5f3e3ec6e8ac7fdd9c334ed2022699206b1ee122eb9fff514e6976"}],"ComponentSizeInKB":5649,"CompsigList":["firmware-hdd-a27c95663d_0HPK6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/CP071813.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/GPM173XAHPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071813.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071813.scexe"],"Name":"firmware-hdd-a27c95663d_0HPK6-2.1_amd64.deb","SHA1Sum":"e873e4959db56ee481b773981471f172e79213ca","SHA256Sum":"8cc9d49395be9eb28151ee3346d04a1a76e8ee5ad87f926b6b8e253d550e8e6d","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3bc62e2d2bcd411692af30d380","SupportedDevices":["4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43","562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072684.exe","SHA1Sum":"10d5274f23ec3bd91ba0f72cbba5c003d6f6576d","SHA256Sum":"0bb3ccad3715da5087f364a4f08119f8f96e5a19c97e5361087fddb0508deb12","SHA512Sum":"d7ce0f6b6d597ab25d87617cba7e70e3e8d9de5d2f0e0afb2caae1bdb0af475fb20fd0502a5a70eed73cf8d944020da328d1462568bb0f78b7a0455e1ad3b0a9"}],"ComponentSizeInKB":1099,"CompsigList":["cp072684.compsig"],"FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.man","bnxtnd.sys","cp072684.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp072684.exe","SHA1Sum":"10d5274f23ec3bd91ba0f72cbba5c003d6f6576d","SHA256Sum":"0bb3ccad3715da5087f364a4f08119f8f96e5a19c97e5361087fddb0508deb12","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"238.1.110.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d0a82fb822934cd4a56234c279","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c1159016d7","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U37","U38","U38","O43","U26","U39","02020001","03020101","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLHCWBA0HPG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"CP072363.zip","SHA1Sum":"3e7fe537fb48810e5934d16c74c40563b9c5d1c7","SHA256Sum":"56599bbe48d5834df4a54faf78f646c93a8a698b1af2e6a08755f5dcf072e598","SHA512Sum":"1743e42cb4ddb3782578a245ab672f6cf36202c627951177c06349f808f0b36e8a62eb9956774aff1fa67549bf2e29bf882e676e5adfa81a7b56bcae78974d83"}],"ComponentSizeInKB":19992,"CompsigList":["CP072363.compsig"],"FileList":["/CP072363_BUILD_1.data","/CP072363.vmexe64","/CP072363.vmfile","/CP072363_VMw.zip","/CP072363.xml","/payload.json","/CP072363_VMw.zip/index.xml","/CP072363_VMw.zip/vendor-index.xml","/CP072363_VMw.zip/metadata.zip","/CP072363_VMw.zip/vib20/CP072363/HPE_bootbank_CP072363_HPG6.1-8.0.0.20613240.vib","/CP072363_VMw.zip/metadata.zip/vendor-index.xml","/CP072363_VMw.zip/metadata.zip/vmware.xml","/CP072363_VMw.zip/metadata.zip/vibs/CP072363--9130305697406643904.xml","/CP072363_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072363_HPG6.1-8.0.0.20613240.xml"],"Name":"CP072363.zip","SHA1Sum":"3e7fe537fb48810e5934d16c74c40563b9c5d1c7","SHA256Sum":"56599bbe48d5834df4a54faf78f646c93a8a698b1af2e6a08755f5dcf072e598","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"2","Version":"HPG6","VibList":[{"Name":"CP072363","Version":"HPG6.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GWDFE Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_07820cc09c7b4bd48f980864a4","SupportedDevices":["4d2340a5-3042-3231-3030-304757444645"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Files":[{"Checksum":[{"Filename":"CP072202.zip","SHA1Sum":"1e30cfbb7ed29b7a43538bffb51344eb3f323d70","SHA256Sum":"5121e652c263afef92ff303bf3f9550d55230d704787763b7d7f61db43f2c587","SHA512Sum":"17040a1d74ebfc890934e370900629acdf9df0a39c28f71b4106bf7cb5985f06b8ac717283c37fba6a6ef034f1a1f7baffc2a8cb0fc3ee7e62f6a20c16de0e11"}],"ComponentSizeInKB":27844,"CompsigList":["CP072202.compsig"],"FileList":["/CP072202_BUILD_1.data","/CP072202.vmcfg","/CP072202.vmexe64","/CP072202.vmfile","/CP072202_VMw.zip","/CP072202.xml","/payload.json","/CP072202_VMw.zip/index.xml","/CP072202_VMw.zip/vendor-index.xml","/CP072202_VMw.zip/metadata.zip","/CP072202_VMw.zip/vib20/CP072202/HPE_bootbank_CP072202_0130.1-8.0.0.20613240.vib","/CP072202_VMw.zip/metadata.zip/vendor-index.xml","/CP072202_VMw.zip/metadata.zip/vmware.xml","/CP072202_VMw.zip/metadata.zip/vibs/CP072202-3501987899116073482.xml","/CP072202_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072202_0130.1-8.0.0.20613240.xml"],"Name":"CP072202.zip","SHA1Sum":"1e30cfbb7ed29b7a43538bffb51344eb3f323d70","SHA256Sum":"5121e652c263afef92ff303bf3f9550d55230d704787763b7d7f61db43f2c587","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130","VibList":[{"Name":"CP072202","Version":"0130.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8c3e4a5f95f245e992ca37eb50","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8173816d98_0HPD6-2.1_amd64.deb","SHA1Sum":"3cc121fb184d5a28e5e34fd587cc0cb41ff510e7","SHA256Sum":"94405ce7e7a5d15d303d91d6875f4d04cf045098a67d0b62f73fcb018c597a05","SHA512Sum":"bbf0be47689a7cc4c6fd1b5a714aceb08b8b1ffff0386adaa0098355ff2a9c7e603f8920ae78de1b2ac10d6559e3dbfefc59f5b986bd298d74bc1cbb709ff067"}],"ComponentSizeInKB":4500,"CompsigList":["firmware-hdd-8173816d98_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/CP071783.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/SHPEEVSBPSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071783.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071783.scexe"],"Name":"firmware-hdd-8173816d98_0HPD6-2.1_amd64.deb","SHA1Sum":"3cc121fb184d5a28e5e34fd587cc0cb41ff510e7","SHA256Sum":"94405ce7e7a5d15d303d91d6875f4d04cf045098a67d0b62f73fcb018c597a05","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b4db6fa551e4400dbd12068749","SupportedDevices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Files":[{"Checksum":[{"Filename":"cp072974.exe","SHA1Sum":"3feb062bceef8a4ff69fc34f1ac07de27238aa80","SHA256Sum":"f1be1de8abd1514fbaafcb5d7eafbb72c42ed749dd0c31fc779682eb2639aee0","SHA512Sum":"f92d1f813d665ce88c14db89e1b9da9b1e568b8acde6395e25c38a3e0f9da5ae8a3b9d5b2a1d8ad4c2d572dabed8ce9de5dd6e3167522056cd0ecc2218508738"}],"ComponentSizeInKB":5028,"CompsigList":["cp072974.compsig"],"FileList":["Config.xml","cp072974.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","Reveille-Release-5.04-build-000.bin","VDUFlash.dll"],"Name":"cp072974.exe","SHA1Sum":"3feb062bceef8a4ff69fc34f1ac07de27238aa80","SHA256Sum":"f1be1de8abd1514fbaafcb5d7eafbb72c42ed749dd0c31fc779682eb2639aee0","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_663302605cc44e07bd03c7f247","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071621.exe","SHA1Sum":"5a7749e1ae2fdfbf89d446dfb15241c1e1892e86","SHA256Sum":"5e116713f7f8f3725af1fb3dbfbfa000a89fa22a5370cf4c9aca67306509cb96","SHA512Sum":"6fc57da3e0db9852ec292f66e473f12b648ce4bab8dfae8602a1599e5d9af2f91fb318e4afc7c112f27f5df28d8b1a0960fc7b9a30e0a61456c340d1ffee6e37"}],"ComponentSizeInKB":3101,"CompsigList":["cp071621.compsig"],"FileList":["cp071621.xml","cpqsetup.exe","cp_data.xml","install.xml","multisetup.dll","StorCLI.msi"],"Name":"cp071621.exe","SHA1Sum":"5a7749e1ae2fdfbf89d446dfb15241c1e1892e86","SHA256Sum":"5e116713f7f8f3725af1fb3dbfbfa000a89fa22a5370cf4c9aca67306509cb96","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2ca7733b"],"TypeOfChange":"1","Version":"7.3811.300.0"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for Windows 64-bit (for Gen10P and Gen11 Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"storcli64.exe","SWKeyExpectedPath":"%programfiles%\\MR Storage Administrator\\StorCLI\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_beb24f23bf464c8bbeba55c829","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","A72","U71","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"CP070973.zip","SHA1Sum":"430a4cafaf15db210e1ec798b78944b959f94d08","SHA256Sum":"9a61c74e3a2731eeb35158351c982178da6170b4608e98a6d5ff313f9d9dd2cf","SHA512Sum":"98cb6947051fedf9a945e8dcfdf64b7a540aa03f814b4693c5212eab379b75e5ae9241d0b3f30dd0965f892d12719685e357263740903ec52d0dbac8594f5ce2"}],"ComponentSizeInKB":19839,"CompsigList":["CP070973.compsig"],"FileList":["/CP070973_BUILD_1.data","/CP070973.vmexe64","/CP070973.vmfile","/CP070973_VMw.zip","/CP070973.xml","/payload.json","/CP070973_VMw.zip/index.xml","/CP070973_VMw.zip/vendor-index.xml","/CP070973_VMw.zip/metadata.zip","/CP070973_VMw.zip/vib20/CP070973/HPE_bootbank_CP070973_HPD3.1-8.0.0.20613240.vib","/CP070973_VMw.zip/metadata.zip/vendor-index.xml","/CP070973_VMw.zip/metadata.zip/vmware.xml","/CP070973_VMw.zip/metadata.zip/vibs/CP070973-8686616375770771222.xml","/CP070973_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070973_HPD3.1-8.0.0.20613240.xml"],"Name":"CP070973.zip","SHA1Sum":"430a4cafaf15db210e1ec798b78944b959f94d08","SHA256Sum":"9a61c74e3a2731eeb35158351c982178da6170b4608e98a6d5ff313f9d9dd2cf","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP070973","Version":"HPD3.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000JXMTH and MB020000JXMTP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0b23aee1aa6a4d6b9845af9a57","SupportedDevices":["4d2340a5-3042-3831-3030-304a584d5448","4d2340a5-3042-3032-3030-304a584d5450"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP070977.zip","SHA1Sum":"e7203020ce26e2ff576b6928d8db60e0d6f9912b","SHA256Sum":"5f78f1b7271189eac337f5faf32aca9389f714b097aaa20903c02d543dd35983","SHA512Sum":"f70ece9413fd69e1d5380e620abb7d78304d4ead6bdceb2f61c27730bed4b543a6fb996a4f863ef8cf2fef1b1870d1eed4b538b35b307a738b1b239e12754254"}],"ComponentSizeInKB":20411,"CompsigList":["CP070977.compsig"],"FileList":["/CP070977_BUILD_1.data","/CP070977.vmexe64","/CP070977.vmfile","/CP070977_VMw.zip","/CP070977.xml","/payload.json","/CP070977_VMw.zip/index.xml","/CP070977_VMw.zip/vendor-index.xml","/CP070977_VMw.zip/metadata.zip","/CP070977_VMw.zip/vib20/CP070977/HPE_bootbank_CP070977_HPD5.1-8.0.0.20613240.vib","/CP070977_VMw.zip/metadata.zip/vendor-index.xml","/CP070977_VMw.zip/metadata.zip/vmware.xml","/CP070977_VMw.zip/metadata.zip/vibs/CP070977--9212995779401950624.xml","/CP070977_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070977_HPD5.1-8.0.0.20613240.xml"],"Name":"CP070977.zip","SHA1Sum":"e7203020ce26e2ff576b6928d8db60e0d6f9912b","SHA256Sum":"5f78f1b7271189eac337f5faf32aca9389f714b097aaa20903c02d543dd35983","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5","VibList":[{"Name":"CP070977","Version":"HPD5.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_315516f1ec37413aab0857e0a7","SupportedDevices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA4_FH_5p0_PLDMoMCTP_80021BD5.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"5.00"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA4_FH_5p0_PLDMoMCTP_80021BD5.fwpkg","SHA1Sum":"6780bf5b59a209db503e4059bae16a44154cdcdb","SHA256Sum":"0c5d5b207268c9f0686bc2d72ba6d36a393908337d7e8c7e89734d931682b8e2","SHA512Sum":"4efc308494f65f69ab9e4dc0158d147563c634421b4a88137390b5bf32b216059339a65b6f427e23aaadce06d1011e057076f3772b93f31bf39e2201ce1663ec"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_XXVDA4_FH_5p0_PLDMoMCTP_80021BD5.HPb","HPE_E810_XXVDA4_FH_5p0_PLDMoMCTP_80021BD5.xml","payload.json"],"Name":"HPE_E810_XXVDA4_FH_5p0_PLDMoMCTP_80021BD5.fwpkg","SHA1Sum":"6780bf5b59a209db503e4059bae16a44154cdcdb","SHA256Sum":"0c5d5b207268c9f0686bc2d72ba6d36a393908337d7e8c7e89734d931682b8e2","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159380860005"],"TypeOfChange":"1","Version":"5.00"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cfe636094af84ccbb92d0b19e0","SupportedDevices":["a6b1a447-382a-5a4f-8086-159380860005"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Files":[{"Checksum":[{"Filename":"CP070868.zip","SHA1Sum":"30ff74b44b224c08505f24534f56f4afb2c73194","SHA256Sum":"d0d511df2501b1c205de724fb8121ee82b1b77767197ab29d94373ba3869d7a2","SHA512Sum":"5b8e6607d9d7a30c063bde67e28a3527f975bc63657c025d483a9632636f9a70e29b203b405d1ce182c2ea2e3db9b9d40626546a08d7561702bae0bb834ccfe3"}],"ComponentSizeInKB":17111,"CompsigList":["CP070868.compsig"],"FileList":["/CP070868_BUILD_3.data","/CP070868.vmexe","/CP070868.vmexe64","/CP070868.vmfile","/CP070868_VMw.zip","/CP070868.xml","/payload.json","/CP070868_VMw.zip/index.xml","/CP070868_VMw.zip/vendor-index.xml","/CP070868_VMw.zip/metadata.zip","/CP070868_VMw.zip/vib20/CP070868/HPE_bootbank_CP070868_5.15.3-8.0.0.20613240.vib","/CP070868_VMw.zip/metadata.zip/vendor-index.xml","/CP070868_VMw.zip/metadata.zip/vmware.xml","/CP070868_VMw.zip/metadata.zip/vibs/CP070868-7075707163769057284.xml","/CP070868_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070868_5.15.3-8.0.0.20613240.xml"],"Name":"CP070868.zip","SHA1Sum":"30ff74b44b224c08505f24534f56f4afb2c73194","SHA256Sum":"d0d511df2501b1c205de724fb8121ee82b1b77767197ab29d94373ba3869d7a2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15","VibList":[{"Name":"CP070868","Version":"5.15.3-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7db5b7e04388458db3d1228278","SupportedDevices":["422340a5-3939-4644-4237-342d07f65795"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A40","U30","P89","U41","A42","U46","U46","A43","A42","A43","A43","A42","U31"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssa-6.65-9.0.x86_64.rpm","SHA1Sum":"32745c5c181925e3108f5d1391a4e6da1a683d36","SHA256Sum":"1b837fc3381ce9f9b070a3305ab9771568dd2ac40a847863b9171dcec8ed6764","SHA512Sum":"52bcad76fe94888d284c2a4c274deec357db1793a1b34a9d9ed499ec78728e1e393a78bddc1d487f08ae1bf8cc1a49056f4000d7f766a48d9d549f7d406d187f"}],"ComponentSizeInKB":9572,"CompsigList":["ssa-6.65-9.0.x86_64.compsig"],"FileList":["./opt/smartstorageadmin/ssa","./opt/smartstorageadmin/ssa/HTML","./opt/smartstorageadmin/ssa/HTML/SSA1","./opt/smartstorageadmin/ssa/HTML/SSA1/css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-bold-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/fonts/hps-euro-regular-woff.woff","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/animated-overlay.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_18_b81900_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_diagonals-thick_20_666666_40x40.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_flat_10_000000_40x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_f6f6f6_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_100_fdf5ce_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_glass_65_ffffff_1x400.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_gloss-wave_35_f6a828_500x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_100_eeeeee_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-bg_highlight-soft_75_ffe45c_1x100.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_222222_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_228ef1_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ef8c08_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffd27a_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/images/ui-icons_ffffff_256x240.png","./opt/smartstorageadmin/ssa/HTML/SSA1/css/jquery/ui-lightness/jquery-ui-1.10.3.custom.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/css/ssa.min.css","./opt/smartstorageadmin/ssa/HTML/SSA1/favicon.ico","./opt/smartstorageadmin/ssa/HTML/SSA1/images","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM","./opt/smartstorageadmin/ssa/HTML/SSA1/images/OEM/logo.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysasssd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/arraysatassd20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/critical20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/degraded20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/embedctrl20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/help20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat12.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/infostat20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/msadevice20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/okay20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/sasssdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdaspare20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdasparerbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassddriverbld20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspare20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdspareerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudrive20.png","./opt/smartstorageadmin/ssa/HTML/SSA1/images/satassdudriveerase20.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/spacer12.gif","./opt/smartstorageadmin/ssa/HTML/SSA1/images/ssa.png","./opt/smartstorageadmin/ssa/HTML/SSA1/index.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/globals.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jBox.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-1.11.2.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-migrate-1.2.1.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery-ui-1.10.3.custom.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.tools.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/jquery.ui.selectablessa.js","./opt/smartstorageadmin/ssa/HTML/SSA1/js/ssa.min.js","./opt/smartstorageadmin/ssa/HTML/SSA1/ssa.htm","./opt/smartstorageadmin/ssa/HTML/SSA1/ssainit.htm","./opt/smartstorageadmin/ssa/HTML/strings","./opt/smartstorageadmin/ssa/HTML/strings/HPE","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HPE/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/HStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/MStrings.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_de_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_en_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_es_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_fr_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_it_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ja_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_pt_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_ru_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/OEM/StringMap_zh_versioned.json","./opt/smartstorageadmin/ssa/HTML/strings/StringMaps.json","./opt/smartstorageadmin/ssa/README.TXT","./opt/smartstorageadmin/ssa/bin","./opt/smartstorageadmin/ssa/bin/ssa","./opt/smartstorageadmin/ssa/bin/ssaclient","./opt/smartstorageadmin/ssa/bin/upgrade.txt","./opt/smartstorageadmin/ssa/ssa.license","./usr/man/man8/ssa.8.gz","./usr/sbin/ssa","./usr/share/smartupdate/ssa/component.xml"],"Name":"ssa-6.65-9.0.x86_64.rpm","SHA1Sum":"32745c5c181925e3108f5d1391a4e6da1a683d36","SHA256Sum":"1b837fc3381ce9f9b070a3305ab9771568dd2ac40a847863b9171dcec8ed6764","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec08c060d2"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) for Linux 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssa","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_81f4244b8dd0486ba9d71c3ba3","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","U63","I45","U58","U58","U58","U59","U54","U54","U63","U54","A56","A56","A55","A55","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U18","U18","U18","U21","U25","U27","U24","U13","U13","U12","U14","U14","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","Carbondale14","Carbondale14","U19","Carbondale14","I40","I37","I39","I40","U57","U65","U62","U65","U71","A66","U71","U68","U68","A66","U68","U72"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"42fc70be-bb87-4bdb-8e7c-db1c9af52957","Devices":{"Device":[{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000242","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000221","Version":"2.1.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-acce-2.1.0-1.1.x86_64.rpm","SHA1Sum":"5ff39f4f7ea1c055210b75c4a7b9dcacaf98d0b9","SHA256Sum":"5ff30191887d6b280a56e0d12484704b9ce4c90184342b0c13db8f710da1e9f1","SHA512Sum":"ca6db0898fe719d3837061b7c30aab3066cce9b05754f4344d64d14c76386555dcdea021ca9b455449688fd47c2cf941710d80fc65566f1644534410cf76029c"}],"ComponentSizeInKB":428,"CompsigList":["firmware-acce-2.1.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/ACCE_2.1.0s.bin","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/CP073070.xml","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-acce-2.1.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073070.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073070.scexe"],"Name":"firmware-acce-2.1.0-1.1.x86_64.rpm","SHA1Sum":"5ff39f4f7ea1c055210b75c4a7b9dcacaf98d0b9","SHA256Sum":"5ff30191887d6b280a56e0d12484704b9ce4c90184342b0c13db8f710da1e9f1","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000242","00000000-0000-0000-0000-00000000023a","00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"2.1.0"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - HPE Edgeline Chassis Controller Firmware","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"ACCE","SWKeyExpectedPath":"firmware:sd:ACC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8f9f5fcb6f21497eb211091633","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","22.04","24.04","26.04","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","HPE Edgeline EL8000t Converged Edge System","FTP","H10","H11","H11"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-megaraid_sas-07.738.06.0_rhel10u2-1.x86_64.rpm","SHA1Sum":"3da214f44e4c3c9c1039e96d3e6de99e96b8eb19","SHA256Sum":"79a0a0cebca842c9ea19732b7d692f11df67880c66794bfcbc2422e7c0fdf650","SHA512Sum":"30a9af8525a789e5051ff0b4f3700e5410afa1de82822f884a3c24f722bc59eb95ebe69362122d0ed7b1dd9b7212e7ea6fead385a332b25a0d4325d7dce52dd8"}],"ComponentSizeInKB":144,"CompsigList":["kmod-megaraid_sas-07.738.06.0_rhel10u2-1.x86_64.compsig"],"FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/megaraid_sas","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"Name":"kmod-megaraid_sas-07.738.06.0_rhel10u2-1.x86_64.rpm","SHA1Sum":"3da214f44e4c3c9c1039e96d3e6de99e96b8eb19","SHA256Sum":"79a0a0cebca842c9ea19732b7d692f11df67880c66794bfcbc2422e7c0fdf650","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.738.06.0"},{"Checksum":[{"Filename":"kmod-megaraid_sas-07.738.06.0_rhel10u1-1.x86_64.rpm","SHA1Sum":"742b6aca76c93920661170a83fba000cc2b6202c","SHA256Sum":"6b3f1ceb945b2b8978db2f338157041aef175835670e3d0bb28a0b52a6766578","SHA512Sum":"283123ae13b0a2f357f075157a5333c2ec4ad55a1480ba1c487eefa06c8e36123b27a00323d0fa17067a10d9fbe6628e5aa5cae00fe0e26b07e8263f45602a3d"}],"ComponentSizeInKB":144,"CompsigList":["kmod-megaraid_sas-07.738.06.0_rhel10u1-1.x86_64.compsig"],"FileList":["./etc/depmod.d/megaraid_sas.conf","./etc/dracut.conf.d/megaraid_sas.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/megaraid_sas","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/megaraid_sas/megaraid_sas.ko","./usr/share/smartupdate/kmod-megaraid_sas/component.xml"],"Name":"kmod-megaraid_sas-07.738.06.0_rhel10u1-1.x86_64.rpm","SHA1Sum":"742b6aca76c93920661170a83fba000cc2b6202c","SHA256Sum":"6b3f1ceb945b2b8978db2f338157041aef175835670e3d0bb28a0b52a6766578","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec2a52c499"],"TypeOfChange":"1","Version":"07.738.06.0"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver for 64-bit Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-megaraid_sas","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_343efb5f46d247279aad328529","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U46","U30","U32","U61","A42","A43","A43","A42","U60","U63","U59","U46","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp073085.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.312"}]},"Files":[{"Checksum":[{"Filename":"firmware-spsgen10-04.01.05.312-1.1.x86_64.rpm","SHA1Sum":"5453c06f43e6181f4fb4846122353aa6a3f7da39","SHA256Sum":"169359e34332a9728f7dadc5325c05da1c367eb15c7f64762a6358b395d8047a","SHA512Sum":"39a431a014e7c1b0e24f4ae89686518d635aabfcfa3f1c1bcf0f1ee952eb14ccf9f448cf45daa3ffaf3d1ed93af5c1abab8cd99ec909393acb30347ca032b7e6"}],"ComponentSizeInKB":3270,"CompsigList":["firmware-spsgen10-04.01.05.312-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1/CP073091.xml","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1/cp073085.compsig","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1/cp073085.zip","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-spsgen10-04.01.05.312-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073091.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073091.scexe"],"Name":"firmware-spsgen10-04.01.05.312-1.1.x86_64.rpm","SHA1Sum":"5453c06f43e6181f4fb4846122353aa6a3f7da39","SHA256Sum":"169359e34332a9728f7dadc5325c05da1c367eb15c7f64762a6358b395d8047a","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.312"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","DeviceGUID":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","SWKey":"IE-Gen10","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"0.1.4.0"}]}]}]},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE Gen10 Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2b826415aa8849ddbbea9a2764","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U41","U33","U40","U39","U45","U37","U38","U38","U39","H08","H08","I43","I42"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6FRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c31543932","Version":"GPK6"},{"DeviceName":"KCM6FRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4652-554c33543834","Version":"GPK6"},{"DeviceName":"KCM6FVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c31543630","Version":"GPK6"},{"DeviceName":"KCM6FVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALFGPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-4656-554c33543230","Version":"GPK6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-1a541ed00d-GPK6-4.1.x86_64.rpm","SHA1Sum":"595a0eb2302237a16f49dfbd798aeae8368ab6bf","SHA256Sum":"a75f21aca37d7f6a11a7d5b1d6c5086c82667593bf09f8b714ec4ff22f732b91","SHA512Sum":"e353a70c1bc074907f0b5683b9f523d1df323bee1302ec378c22caa2f37fa9d5f18bb39c0b20d4997b4bc49d2eaac4dad8e6302bdc4239f35be6955c9756cab4"}],"ComponentSizeInKB":6385,"CompsigList":["firmware-hdd-1a541ed00d-GPK6-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/CP068925.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/KACM6ALFGPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-1a541ed00d-GPK6-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068925.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068925.scexe"],"Name":"firmware-hdd-1a541ed00d-GPK6-4.1.x86_64.rpm","SHA1Sum":"595a0eb2302237a16f49dfbd798aeae8368ab6bf","SHA256Sum":"a75f21aca37d7f6a11a7d5b1d6c5086c82667593bf09f8b714ec4ff22f732b91","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c31543630","002340a5-434b-364d-4656-554c33543230"],"TypeOfChange":"1","Version":"GPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - KCM6FRUL1T92, KCM6FRUL3T84, KCM6FVUL1T60 and KCM6FVUL3T20  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6FRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6FVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f99825a1487a46a4b05ef9db9b","SupportedDevices":["002340a5-434b-364d-4652-554c31543932","002340a5-434b-364d-4652-554c33543834","002340a5-434b-364d-4656-554c33543230","002340a5-434b-364d-4656-554c31543630"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"CP070926.zip","SHA1Sum":"e5ca82dc1ea061ff5360df32122e8316d54fc2c2","SHA256Sum":"ef51f38d976605891d2612df2b6c3154f22fd428705deabd2d0e48546cb5d5ec","SHA512Sum":"4a56992042c8fdc60ebd2bcc215f5ec0527d98b35499a7f1a370ad65648100f0e37f76b04ec56ba2846abc5c2a325b915944a659290ab860436b8835755192b2"}],"ComponentSizeInKB":17627,"CompsigList":["CP070926.compsig"],"FileList":["/CP070926_BUILD_2.data","/CP070926.vmexe64","/CP070926.vmfile","/CP070926_VMw.zip","/CP070926.xml","/payload.json","/CP070926_VMw.zip/index.xml","/CP070926_VMw.zip/vendor-index.xml","/CP070926_VMw.zip/metadata.zip","/CP070926_VMw.zip/vib20/CP070926/HPE_bootbank_CP070926_HPDB.2-8.0.0.20613240.vib","/CP070926_VMw.zip/metadata.zip/vendor-index.xml","/CP070926_VMw.zip/metadata.zip/vmware.xml","/CP070926_VMw.zip/metadata.zip/vibs/CP070926-5751307503826378903.xml","/CP070926_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070926_HPDB.2-8.0.0.20613240.xml"],"Name":"CP070926.zip","SHA1Sum":"e5ca82dc1ea061ff5360df32122e8316d54fc2c2","SHA256Sum":"ef51f38d976605891d2612df2b6c3154f22fd428705deabd2d0e48546cb5d5ec","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP070926","Version":"HPDB.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA, EO001600JWTCB  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_20ee252f4a0f422bb799cfa92b","SupportedDevices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U38_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u38-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"b23d9d8c58d3674468fa952426189870c2892ce7","SHA256Sum":"c7365169e6b6debeadee73716532e072b57d12a03a0d3940d88bd653a4d53143","SHA512Sum":"da8e301054c0351b375eb3a65533471692d59bc61804dba49218ad7d8e1a4a7ede76a3e949911c28588ed3d503f348b76727fa5a307b87dac0b4c1b41d6c74d0"}],"ComponentSizeInKB":11549,"CompsigList":["firmware-system-u38-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.70_2026_08_19-1.1/CP073175.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.70_2026_08_19-1.1/U38_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u38-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073175.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073175.scexe"],"Name":"firmware-system-u38-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"b23d9d8c58d3674468fa952426189870c2892ce7","SHA256Sum":"c7365169e6b6debeadee73716532e072b57d12a03a0d3940d88bd653a4d53143","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_37c1be902d964fa28a6790766c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","6.0","11.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U38","U38","U38","U38","U38"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b04df66fe9-HPD5-2.1.x86_64.rpm","SHA1Sum":"cb33486cafbd20d0f1298d22a21169bd35d9edb8","SHA256Sum":"2e17168c58f84f9e4b4626f9bba5c8c35e138c6ab510427abbed453f4f92b556","SHA512Sum":"c789c15352edac3a9ef32a9c4298d01896173dfe369bea59429c90f9455773fedefbc8c7d3cf8a0dc74c38af318f79046d9c2bf73655683aecb3ff10ad669dd3"}],"ComponentSizeInKB":6379,"CompsigList":["firmware-hdd-b04df66fe9-HPD5-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/CP068805.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/SCIMARBPESD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b04df66fe9-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068805.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068805.scexe"],"Name":"firmware-hdd-b04df66fe9-HPD5-2.1.x86_64.rpm","SHA1Sum":"cb33486cafbd20d0f1298d22a21169bd35d9edb8","SHA256Sum":"2e17168c58f84f9e4b4626f9bba5c8c35e138c6ab510427abbed453f4f92b556","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4e33cb3609b14b61a246f9ddee","SupportedDevices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H08","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H08_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000221","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"H08_3.70_08_19_2026.fwpkg","SHA1Sum":"61d72aa5891ef5b5358ec304c5f5ddd912b0ed8f","SHA256Sum":"4683b6b6b59fea1d57f491379404e677bc0da76b6ad61a82ac21180f23447485","SHA512Sum":"079f1d46b0c31504ec8d96a95744485a61bc953b765d8b9225a9c7c9a3bef261a0ee99ab279936c321735db1763d9629bfaf2b2277b291b596272f422c2d0761"}],"ComponentSizeInKB":32802,"CompsigList":[],"FileList":["H08_3.70_08_19_2026.signed.flash","H08_3.70_08_19_2026.xml","payload.json"],"Name":"H08_3.70_08_19_2026.fwpkg","SHA1Sum":"61d72aa5891ef5b5358ec304c5f5ddd912b0ed8f","SHA256Sum":"4683b6b6b59fea1d57f491379404e677bc0da76b6ad61a82ac21180f23447485","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant e910/e910t Server Blade (H08)","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H08","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_012ce77813e64b0fb9fecfe35e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","6.7","6.5","6.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070980.zip","SHA1Sum":"cff9e1d4aafe4a1f7abd42db7e86a6377be48d48","SHA256Sum":"49e46b102ce09ef37867725f02d89940097a68a49f75cb0ea8a9c09d8985544c","SHA512Sum":"042d1af5ab606ff2a94c776681f9150eeccdc049ad54436ad4cfb7b518124394110f304a0e42a5ffafcdc226a2a2e13d6a7d4de913388b25e1039231ad6a37d9"}],"ComponentSizeInKB":19432,"CompsigList":["CP070980.compsig"],"FileList":["/CP070980_BUILD_1.data","/CP070980.vmexe64","/CP070980.vmfile","/CP070980_VMw.zip","/CP070980.xml","/payload.json","/CP070980_VMw.zip/index.xml","/CP070980_VMw.zip/vendor-index.xml","/CP070980_VMw.zip/metadata.zip","/CP070980_VMw.zip/vib20/CP070980/HPE_bootbank_CP070980_HPG1.1-8.0.0.20613240.vib","/CP070980_VMw.zip/metadata.zip/vendor-index.xml","/CP070980_VMw.zip/metadata.zip/vmware.xml","/CP070980_VMw.zip/metadata.zip/vibs/CP070980-8031440250491075634.xml","/CP070980_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070980_HPG1.1-8.0.0.20613240.xml"],"Name":"CP070980.zip","SHA1Sum":"cff9e1d4aafe4a1f7abd42db7e86a6377be48d48","SHA256Sum":"49e46b102ce09ef37867725f02d89940097a68a49f75cb0ea8a9c09d8985544c","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070980","Version":"HPG1.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0bb9e1358c3844569b41cf17a7","SupportedDevices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-92d876cfea-4ICRHPK3-15.1.x86_64.rpm","SHA1Sum":"4a3ccd3b466572bc8b5004fac711e56f22567fd5","SHA256Sum":"1ae2ea17b7661bb2d2409f06a4e2f2508f3c5dcd351a7ac0230aad2502d9efcc","SHA512Sum":"7a54d8e5dd70b82458ceb2b715011f527c6bacbb480ae866cef71ee60259037a0ad39c1b928ce7242c6a04260aadec6757dc6f8cabe4f7d6c8e631cd070491af"}],"ComponentSizeInKB":5261,"CompsigList":["firmware-hdd-92d876cfea-4ICRHPK3-15.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/4ICRHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/CP068776.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068776.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068776.scexe"],"Name":"firmware-hdd-92d876cfea-4ICRHPK3-15.1.x86_64.rpm","SHA1Sum":"4a3ccd3b466572bc8b5004fac711e56f22567fd5","SHA256Sum":"1ae2ea17b7661bb2d2409f06a4e2f2508f3c5dcd351a7ac0230aad2502d9efcc","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c40a36ef0eb14c6ca2d92be35d","SupportedDevices":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM4 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM4_1.28_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"9675b54e-1c96-44c3-a7a1-901504000000","Version":"1.28"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM4_1.28_A.fwpkg","SHA1Sum":"eea641e905c4d17eede010160e4c9312951edaa0","SHA256Sum":"b51cc22e1ea974bee1ce2c9166bdc1a8a837670a4780214598ad87ecf7446709","SHA512Sum":"7b92c09a6fc05c7f8de6b9dc416fa967c169afe4a8bad0491468457a5fd97494eb926c020a5dc38d195ecb86ec2990e4322402e084f6d900121a86ad5532a096"}],"ComponentSizeInKB":56,"CompsigList":[],"FileList":["HPE_UBM4_1.28_A.HPb"],"Name":"HPE_UBM4_1.28_A.fwpkg","SHA1Sum":"eea641e905c4d17eede010160e4c9312951edaa0","SHA256Sum":"b51cc22e1ea974bee1ce2c9166bdc1a8a837670a4780214598ad87ecf7446709","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901504000000"],"TypeOfChange":"1","Version":"1.28"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"Name":"Firmware Package - UBM4 Backplane PIC PLDM Firmware for Gen10P/Gen11/Gen12 servers usage","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM4PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_54772058817b4c3bba32c6f330","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","7.0","12.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I45","A55","A55","A56","A56","U54","U54","U63","U58","U58","U59","U46","A42","U46","A43","A43","A42","U46","U69","U69","R11","U71","U71"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"cp068659.exe","SHA1Sum":"af6ea578929b6ee878c66beca85c3a65bba7cca4","SHA256Sum":"dac205138011be8e9ea207df82eee79d86ed2d02409c0c4ecd17016ae470a7a0","SHA512Sum":"cb355d0b58a75244daaf6c37688266f0efa4abe7a18ec009354b32dba3e3bddf020d1b9837ac0c8ff27181c73c13081c61b77779085eb1f3aef3ef1d51a25311"}],"ComponentSizeInKB":4230,"CompsigList":["cp068659.compsig"],"FileList":["cp068659.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SMOBULABPSD2.rel"],"Name":"cp068659.exe","SHA1Sum":"af6ea578929b6ee878c66beca85c3a65bba7cca4","SHA256Sum":"dac205138011be8e9ea207df82eee79d86ed2d02409c0c4ecd17016ae470a7a0","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7d67acb393844eddb9adb9967c","SupportedDevices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG6"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG6"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG6"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e0171a2936_0HPG6-2.1_amd64.deb","SHA1Sum":"fb2cc90644ea59db85f7c012b4053bf4a9e02e87","SHA256Sum":"a2f8ee7c30090d2319b01ad79416acc6aa852e505b09da4775fd64a79f9ce491","SHA512Sum":"ee38aeb64b85a9c5e964d9d1bd39d0594eb8a9cc7933a0d7d8a858a256e9bdfbd6cecca0a3b839a8c501ed0bc5720f20aa5d59ab0d9f18004c6cf588fa880e14"}],"ComponentSizeInKB":4491,"CompsigList":["firmware-hdd-e0171a2936_0HPG6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/CP071790.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/TAMG09acHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071790.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071790.scexe"],"Name":"firmware-hdd-e0171a2936_0HPG6-2.1_amd64.deb","SHA1Sum":"fb2cc90644ea59db85f7c012b4053bf4a9e02e87","SHA256Sum":"a2f8ee7c30090d2319b01ad79416acc6aa852e505b09da4775fd64a79f9ce491","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_736373fe26494dd29398bb40cc","SupportedDevices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57414 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957414A4142HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d714e41597","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957414A4142HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ec14e41597","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57414 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957414A4142HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16ed14e41597","Version":"238.1.169.0"}]},"Files":[{"Checksum":[{"Filename":"BCM238.1.169.0_BCM957414A4142HC.fwpkg","SHA1Sum":"6517020805709ef78ec08c6963912518b615c80e","SHA256Sum":"bdb95302db4945689bbf36b722fb5fafbc72f1ed9f35ac54a0aa5e52a2003369","SHA512Sum":"f747a2b4f78dc63e62922f821156026122e19a756a3f2aed5e4956f9e54c597fa80823f6504149a3c21b69def09137df06d572ec29730fc97db86ee24fa249e9"}],"ComponentSizeInKB":1430,"CompsigList":[],"FileList":["BCM238.1.169.0_BCM957414A4142HC.HPb","BCM238.1.169.0_BCM957414A4142HC.xml","payload.json"],"Name":"BCM238.1.169.0_BCM957414A4142HC.fwpkg","SHA1Sum":"6517020805709ef78ec08c6963912518b615c80e","SHA256Sum":"bdb95302db4945689bbf36b722fb5fafbc72f1ed9f35ac54a0aa5e52a2003369","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41597"],"TypeOfChange":"1","Version":"238.1.169.0"}],"InstallationDependency":{},"Name":"Broadcom Firmware Package for BCM57414 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE_57414_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_135e5222c6bf4449a335649d77","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41597"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072286.exe","SHA1Sum":"2836b16187e3194c33a20cc2da1d1d08f5d2b63a","SHA256Sum":"98445fa23eaf0b37e93477f49df82077d8a3b4f3b407d0b1295e0010f97491fc","SHA512Sum":"18f72576f7f04894a8dc3f53d6bb3f6cc4a22a7f1f7f6ad5246a9fdfcee8c4bdab222d6ffde0b9516f8e47f01ea776d8580a88363fa2501b6c41bdeff6ddd2b8"}],"ComponentSizeInKB":1407,"CompsigList":["cp072286.compsig"],"FileList":["cp072286.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","manifest_iavf68.man","nicdrvr.dll"],"Name":"cp072286.exe","SHA1Sum":"2836b16187e3194c33a20cc2da1d1d08f5d2b63a","SHA256Sum":"98445fa23eaf0b37e93477f49df82077d8a3b4f3b407d0b1295e0010f97491fc","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"TypeOfChange":"1","Version":"1.19.113.0"}],"InstallationDependency":{},"Name":"Intel iavf Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"iavf68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4637f1033165432baa49b033c4","SupportedDevices":["a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-188980860000","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-37cd80860001"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR216i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR216i-a_Gen10P_52.38.3-6909_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.38.3-6909"}]},"Files":[{"Checksum":[{"Filename":"HPE_MR216i-a_Gen10P_52.38.3-6909_A.fwpkg","SHA1Sum":"ee1b458a5a2338692108c69413e388fa6512865e","SHA256Sum":"5214e972d8eb347a5c262ac362f3af4656ab4834b8bca2ad02f5bf4a1626f8e2","SHA512Sum":"e7e25687abcd9fb1a73f7be51526dfecec03ab750edb2f9a9c0252a897d390d8dfdf4e13c4115f0e6878550a99a10591602891fdbc52cad6c789451230dfabe1"}],"ComponentSizeInKB":7347,"CompsigList":[],"FileList":["HPE_MR216i-a_Gen10P_52.38.3-6909_A.HPb","HPE_MR216i-a_Gen10P_52.38.3-6909_A.xml","payload.json"],"Name":"HPE_MR216i-a_Gen10P_52.38.3-6909_A.fwpkg","SHA1Sum":"ee1b458a5a2338692108c69413e388fa6512865e","SHA256Sum":"5214e972d8eb347a5c262ac362f3af4656ab4834b8bca2ad02f5bf4a1626f8e2","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032c"],"TypeOfChange":"1","Version":"52.38.3-6909"}],"InstallationDependency":{},"MinimumActiveVersion":"52.26.3.5487","Name":"Firmware Package - HPE MR216i-a Gen10 Plus Tri Mode Controller","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"032C1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_56d7e63aed554aa396dc8a5af0","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","A43","A43","A42","U60","U46","U61","A59","U84","A72","U48","U64"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070958.zip","SHA1Sum":"075ef07e003ee69d4a16509f83a826b389107784","SHA256Sum":"796e933eb1c001bf17a2cd34b137037289fffbf76c8b0aa20263db42933029b5","SHA512Sum":"b137a06a7425e6f1727008d07754c32fb006f5c8e9e278fd3c43a2193984e6a81717cc2946703a9d34ead9afae9596ba0eb4cd75f14268b29f9b116685ac86d9"}],"ComponentSizeInKB":18402,"CompsigList":["CP070958.compsig"],"FileList":["/CP070958_BUILD_3.data","/CP070958.vmexe64","/CP070958.vmfile","/CP070958_VMw.zip","/CP070958.xml","/payload.json","/CP070958_VMw.zip/index.xml","/CP070958_VMw.zip/vendor-index.xml","/CP070958_VMw.zip/metadata.zip","/CP070958_VMw.zip/vib20/CP070958/HPE_bootbank_CP070958_HPG1.3-8.0.0.20613240.vib","/CP070958_VMw.zip/metadata.zip/vendor-index.xml","/CP070958_VMw.zip/metadata.zip/vmware.xml","/CP070958_VMw.zip/metadata.zip/vibs/CP070958--6853494265629143548.xml","/CP070958_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070958_HPG1.3-8.0.0.20613240.xml"],"Name":"CP070958.zip","SHA1Sum":"075ef07e003ee69d4a16509f83a826b389107784","SHA256Sum":"796e933eb1c001bf17a2cd34b137037289fffbf76c8b0aa20263db42933029b5","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070958","Version":"HPG1.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7bcf258c03cd4168a6f023bf56","SupportedDevices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A47_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a47-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"2e9cf730e768cf0c6afbcf62be285028caeaa09d","SHA256Sum":"db7c0c12237ffd5d2b5478a9d539a1da7307f2a5a8305c14e38cfa44785b1e52","SHA512Sum":"45216853afdae3333228c55d457d39e7f06747257fd521f237367e9e6db7c0da8afb15a5cfff4dabaa82140bb2b45ff58bfa52a67095bc62679740fa6a2403ac"}],"ComponentSizeInKB":33239,"CompsigList":["firmware-system-a47-4.04_2026_04_02-1.1.x86_64_part2.compsig","firmware-system-a47-4.04_2026_04_02-1.1.x86_64_part1.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/A47_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/CP071586.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a47-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071586.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071586.scexe"],"Name":"firmware-system-a47-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"2e9cf730e768cf0c6afbcf62be285028caeaa09d","SHA256Sum":"db7c0c12237ffd5d2b5478a9d539a1da7307f2a5a8305c14e38cfa44785b1e52","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a87bb893bc0c4ad4976f4fac8b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","10.0","9.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A47","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U47_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000227","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u47-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"f7b42589909e66a26560da9fae462f515c4b6d6d","SHA256Sum":"07e6c45db8b44d8e09fa6135adcab2f9e96d74feafa0d796387633115d60d330","SHA512Sum":"6047e24f4054549d3e3b69f1d99e14204f7372473c8d4403291ff35b0a6d5eca027c6bcfde26fa4f60aa1259b5743d8c5c9db9c79a417c64745690339b5f4820"}],"ComponentSizeInKB":33282,"CompsigList":["firmware-system-u47-2.70_2026_08_19-1.1.x86_64_part2.compsig","firmware-system-u47-2.70_2026_08_19-1.1.x86_64_part1.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.70_2026_08_19-1.1/CP073104.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.70_2026_08_19-1.1/U47_2.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u47-2.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073104.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073104.scexe"],"Name":"firmware-system-u47-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"f7b42589909e66a26560da9fae462f515c4b6d6d","SHA256Sum":"07e6c45db8b44d8e09fa6135adcab2f9e96d74feafa0d796387633115d60d330","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000227"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant XL220n/XL290n Gen10 Plus 1U Node and 2U Node Configure-to-order Server (U47)","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d90df28f9e8649d1bf908f526e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U47","U47"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ixgbe-kmp-default-6.4.4_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"e84d11d7a8dff73d0cca57cb27bcfd36c780b3e7","SHA256Sum":"65b9363887ad89f6493054e4081ebaf4141e56e3f422107490cb4aecc0c05691","SHA512Sum":"f6ee464d7c301aa826ebee0b5eb0ca7305613958e05776eec87d0c36a203aa556e9add9e6a54e977d6ca5b23b4d3be82b3583fb3f09ce6b270576bc5c0822a2a"}],"ComponentSizeInKB":442,"CompsigList":["ixgbe-kmp-default-6.4.4_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/ixgbe.ko","./usr/share/doc/packages/ixgbe-kmp-default","./usr/share/doc/packages/ixgbe-kmp-default/COPYING","./usr/share/doc/packages/ixgbe-kmp-default/README","./usr/share/man/man7/ixgbe.7.gz","./usr/share/pci.ids.d/pci.ids.ixgbe-kmp-6.4.4","./usr/share/smartupdate/ixgbe-kmp-default/component.xml"],"Name":"ixgbe-kmp-default-6.4.4_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"e84d11d7a8dff73d0cca57cb27bcfd36c780b3e7","SHA256Sum":"65b9363887ad89f6493054e4081ebaf4141e56e3f422107490cb4aecc0c05691","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb870faaa"],"TypeOfChange":"1","Version":"6.4.4-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fcff21ff9a944665b0611f2432","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071622.zip","SHA1Sum":"79d66eb3109dc2c4277e8e06b5dbdf3886ace327","SHA256Sum":"c46b0dfd5b95a2ea4d0f11884a4370267bbff43050a447b8c98bcfe73710807d","SHA512Sum":"3a4c0b03a2397646320ce84f6f241fbe7f640a93cd9698a05b051eb1026309920d35250309ca78d629a0d225ac0b442960f26818f40af4ebafd4a56f6f4e6935"}],"ComponentSizeInKB":16807,"CompsigList":["cp071622.compsig"],"FileList":["/BCM-storcli_007.3811.0300-01.zip","/BCM_bootbank_storcli_007.3811.0300-01.vib","/cp071622.xml","/BCM-storcli_007.3811.0300-01.zip/index.xml","/BCM-storcli_007.3811.0300-01.zip/vendor-index.xml","/BCM-storcli_007.3811.0300-01.zip/metadata.zip","/BCM-storcli_007.3811.0300-01.zip/vib20/storcli/BCM_bootbank_storcli_007.3811.0300-01.vib","/BCM-storcli_007.3811.0300-01.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3811.0300-01.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3811.0300-01.zip/metadata.zip/vibs/storcli--952383875572067941.xml","/BCM-storcli_007.3811.0300-01.zip/metadata.zip/bulletins/BCM-storcli_007.3811.0300-01.xml"],"Name":"cp071622.zip","SHA1Sum":"79d66eb3109dc2c4277e8e06b5dbdf3886ace327","SHA256Sum":"c46b0dfd5b95a2ea4d0f11884a4370267bbff43050a447b8c98bcfe73710807d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2026.09.01","VibList":[{"Name":"storcli","Version":"007.3811.0300-01"}]}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for VMware8.0 (For Gen10P and Gen11 Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"BCM-storcli:007.3811.0300-01","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3811.0300-01","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1dd76d6e014e4441a78996be34","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U54","U54","U54","U58","U63","U58","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","A72","U71","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB NDR200/EN 200G 1p OSFP Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.signed","InstallDurationSec":900,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-102115b30085","Version":"28.49.1014"}]},"Files":[{"Checksum":[{"Filename":"28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.fwpkg","SHA1Sum":"42d62ce023470bd177169a833920a6dad9d62f5a","SHA256Sum":"532147711a3796789474b755ca7b7b43cedd1108666f24cef27684ef74cbf317","SHA512Sum":"7e7acb9c9dfbd7155294a71ed97e9fd1afae3fcd0d179ae1f8401d0ebc12da35568e9805384c75593b5c81360f2140da8ecfceb7fe57a997edc05b4ece47001d"}],"ComponentSizeInKB":9397,"CompsigList":[],"FileList":["28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.signed","28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.xml","payload.json"],"Name":"28_49_1014-MCX75310AAS-HEAT_HPE2_Ax.pldm.fwpkg","SHA1Sum":"42d62ce023470bd177169a833920a6dad9d62f5a","SHA256Sum":"532147711a3796789474b755ca7b7b43cedd1108666f24cef27684ef74cbf317","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-102115b30085"],"TypeOfChange":"1","Version":"28.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand NDR200/Ethernet 200Gb 1-port OSFP PCIe5 x16 MCX75310AAS-HEAT Adapter : HPE part numbers  P45642-B22 and P45642-H22","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":900,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX75310AAS-HEAT_VPI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_13c7d34506c44a52be6fdd355e","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30085"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0","10.0"]},{"OS":"VMware","Version":["9.0","8.0","7.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","U63","A55","A55","A56","A56","U59","U58","U72","U70","A59","U66","U71","U71","U68","U68","U68","A66","A66","U72"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1.x86_64.rpm","SHA1Sum":"96e69ad710f39b2d9f9453a622a9ede92c5a1e04","SHA256Sum":"a58de6ead5c4a03aaa4f1c04989a6bf38b910fd1492414d56c09250358d1264d","SHA512Sum":"a239d890a2c628a1b26554f464fec5669dee973b0ad83998ee2676460129397d347d9b34bb1b2c918989a43cf188abf613dfbf5a0b65e9ef3c110c374d2d661d"}],"ComponentSizeInKB":9614,"CompsigList":["firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/CP072398.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072398.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072398.scexe"],"Name":"firmware-hca-mellanox-vpi-connectx4-1.0.20-1.1.x86_64.rpm","SHA1Sum":"96e69ad710f39b2d9f9453a622a9ede92c5a1e04","SHA256Sum":"a58de6ead5c4a03aaa4f1c04989a6bf38b910fd1492414d56c09250358d1264d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.20"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on Linux x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_42a5424fc6714cbeb6b3632056","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","8.0","9.0","12.0","15.0","16.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","U31","U31","U41","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"MLX MCX6314 10/25GbE 2p SFP28 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_49_1014-MCX631432AS-ADA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101f15b30007","Version":"26.49.1014"}]},"Files":[{"Checksum":[{"Filename":"26_49_1014-MCX631432AS-ADA_Ax.pldm.fwpkg","SHA1Sum":"313745cff3a80c63db206cbb3be8bbc126629478","SHA256Sum":"ac350ec06a178ba9a4498a67a1cf39d2c9a04004bae355ddbe788d4287bc32e8","SHA512Sum":"adfefe221f94d7b4ce7714e1fbcc5762aca6bed02b44ea9fc86cfec75de4a295acd95590fa7c6c13a3c86b0e4eb122483916179927d8c1baab768d1e507fd4cc"}],"ComponentSizeInKB":7184,"CompsigList":[],"FileList":["26_49_1014-MCX631432AS-ADA_Ax.pldm.signed","26_49_1014-MCX631432AS-ADA_Ax.pldm.xml","payload.json"],"Name":"26_49_1014-MCX631432AS-ADA_Ax.pldm.fwpkg","SHA1Sum":"313745cff3a80c63db206cbb3be8bbc126629478","SHA256Sum":"ac350ec06a178ba9a4498a67a1cf39d2c9a04004bae355ddbe788d4287bc32e8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f15b30007"],"TypeOfChange":"1","Version":"26.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) - Mellanox MCX631432AS-ADAI Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX631432AS-ADAI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_26ed76e01e9a47fea5fd1b580a","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f15b30007"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U62","U63","U57","A55","A55","A56","A56","U59","U58","U69","U69","U72","U70","U63","U65","U68","U68","U68","U66","A66","A66","U72","U77","A72"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070906.zip","SHA1Sum":"895f07a386d908cd9b52be454b65bbfdf02c555b","SHA256Sum":"8db5ab0a0198d619cd4fb4e20ef27f1dbc47ecb5dfdd72d4d012879c5a12589b","SHA512Sum":"04ec9d65dd55834baa688ede36760048422c21128be0f5f5116b94c9aec35da1f746a69ec4f0e7059dd708a167e1031d3711f29bdcb83c8da9f3c77914cdbf6a"}],"ComponentSizeInKB":26252,"CompsigList":["CP070906.compsig"],"FileList":["/CP070906_BUILD_4.data","/CP070906.vmexe64","/CP070906.vmfile","/CP070906_VMw.zip","/CP070906.xml","/payload.json","/CP070906_VMw.zip/index.xml","/CP070906_VMw.zip/vendor-index.xml","/CP070906_VMw.zip/metadata.zip","/CP070906_VMw.zip/vib20/CP070906/HPE_bootbank_CP070906_HPG3.4-8.0.0.20613240.vib","/CP070906_VMw.zip/metadata.zip/vendor-index.xml","/CP070906_VMw.zip/metadata.zip/vmware.xml","/CP070906_VMw.zip/metadata.zip/vibs/CP070906--8050592796358486694.xml","/CP070906_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070906_HPG3.4-8.0.0.20613240.xml"],"Name":"CP070906.zip","SHA1Sum":"895f07a386d908cd9b52be454b65bbfdf02c555b","SHA256Sum":"8db5ab0a0198d619cd4fb4e20ef27f1dbc47ecb5dfdd72d4d012879c5a12589b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070906","Version":"HPG3.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_16bc02ecd29b4d0fba5f0cfb39","SupportedDevices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150600.21-150.1.sles15sp6.x86_64.rpm","SHA1Sum":"ee69d688055dd32b0781180538a84d77b5275605","SHA256Sum":"f717708c908e581db9e102f66932c57ff1afc88e875ff32e0d1b23d8631b4da9","SHA512Sum":"1f505cd7846de4a144bbca5bbc9ebaf4b8d2d529b39d81c873130aa947fbca34a2c3e5cac13f07596db3ae73a1480e07294a010ce72f4663e7890ecfd0b552fe"}],"ComponentSizeInKB":78,"CompsigList":["kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150600.21-150.1.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/mst_pci.ko","./lib/modules/6.4.0-150600.21-default/updates/mst_pciconf.ko","./usr/share/smartupdate/kernel-mft-mlnx-kmp-default/component.xml"],"Name":"kernel-mft-mlnx-kmp-default-4.36.0_k6.4.0_150600.21-150.1.sles15sp6.x86_64.rpm","SHA1Sum":"ee69d688055dd32b0781180538a84d77b5275605","SHA256Sum":"f717708c908e581db9e102f66932c57ff1afc88e875ff32e0d1b23d8631b4da9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"mft-4.36.0-147.sles15sp6.x86_64.rpm","SHA1Sum":"0a0cdda1ff29c4608f69e0eb22da35e27a365c0d","SHA256Sum":"656892c414ea5f8c346af2876c6631376fbefb681069024d13bbcb152aa25133","SHA512Sum":"a87bd750a9881b7463cea4384e8b9e7551d93d7faab0b566aa15a66e450919a8625739ec9a146f506df7cb5211fe5cb27a56db967728c71d6d13f00313759bd5"}],"ComponentSizeInKB":29836,"CompsigList":["mft-4.36.0-147.sles15sp6.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.sles15sp6.x86_64.rpm","SHA1Sum":"0a0cdda1ff29c4608f69e0eb22da35e27a365c0d","SHA256Sum":"656892c414ea5f8c346af2876c6631376fbefb681069024d13bbcb152aa25133","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for SUSE Linux Enterprise Server 15 SP6 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kernel-mft-mlnx-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_286ec51774394c74a66df96ff7","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","03030201","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b58554a54","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b58554a55","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58554a56","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58554b41","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b58554a4e","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b58554a50","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b58554a51","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b58554a52","Version":"HPK3"},{"DeviceName":"Kioxia-CD8-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_CD8_KACD8ALSHPK3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3531-3336-304b59475a51","Version":"HPK3"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_CD8_KACD8ALSHPK3.fwpkg","SHA1Sum":"2dbfae94556f62477d6cf57a4f50c4697a0f2e36","SHA256Sum":"879e1af39616e1d8a4360d3b776f772800515c3aa89850aa267116baab85475d","SHA512Sum":"c602394bc6732d6b18596884608f429b86673da520b2b68b37f93f9ddc626237622ecd2dc532d397c3155bfba88631f2641a3cb49c220fa588f3bbaeabebccf4"}],"ComponentSizeInKB":2077,"CompsigList":[],"FileList":["Kioxia_CD8_KACD8ALSHPK3.HPb","Kioxia_CD8_KACD8ALSHPK3.xml","payload.json"],"Name":"Kioxia_CD8_KACD8ALSHPK3.fwpkg","SHA1Sum":"2dbfae94556f62477d6cf57a4f50c4697a0f2e36","SHA256Sum":"879e1af39616e1d8a4360d3b776f772800515c3aa89850aa267116baab85475d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304b58554a54","4d2340a5-304f-3130-3630-304b58554a55","4d2340a5-304f-3330-3230-304b58554a56","4d2340a5-304f-3630-3430-304b58554b41","562340a5-304f-3030-3936-304b58554a4e","562340a5-304f-3130-3932-304b58554a50","562340a5-304f-3330-3834-304b58554a51","562340a5-304f-3730-3638-304b58554a52","562340a5-304f-3531-3336-304b59475a51"],"TypeOfChange":"1","Version":"HPK3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO000800KXUJT, MO001600KXUJU, MO003200KXUJV, MO006400KXUKA, VO000960KXUJN, VO001920KXUJP, VO003840KXUJQ, VO007680KXUJR and VO015360KYGZQ","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MO000800KXUJT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXUJU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXUJV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXUKA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KXUJN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXUJP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXUJQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXUJR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYGZQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8e76fb6200624a4db4f41115e1","SupportedDevices":["4d2340a5-304f-3030-3830-304b58554a54","4d2340a5-304f-3130-3630-304b58554a55","4d2340a5-304f-3330-3230-304b58554a56","4d2340a5-304f-3630-3430-304b58554b41","562340a5-304f-3030-3936-304b58554a4e","562340a5-304f-3130-3932-304b58554a50","562340a5-304f-3330-3834-304b58554a51","562340a5-304f-3730-3638-304b58554a52","562340a5-304f-3531-3336-304b59475a51"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070909.zip","SHA1Sum":"de0967bb06664cd4ced8a8481234bc7cffe2cdd2","SHA256Sum":"ead59706ea2540add06539a03007509499b86c5a180fe8e08cf96c2c96190cc2","SHA512Sum":"45a69f6224afcf579650e13368f7cb813d9b166ee7455c7f8d2b4358ea9d205965390c0b6faad69d15131ce3a32c21ae8bae7bc859d8476e65490889dc882120"}],"ComponentSizeInKB":27288,"CompsigList":["CP070909.compsig"],"FileList":["/CP070909_BUILD_4.data","/CP070909.vmexe64","/CP070909.vmfile","/CP070909_VMw.zip","/CP070909.xml","/payload.json","/CP070909_VMw.zip/index.xml","/CP070909_VMw.zip/vendor-index.xml","/CP070909_VMw.zip/metadata.zip","/CP070909_VMw.zip/vib20/CP070909/HPE_bootbank_CP070909_HPG3.4-8.0.0.20613240.vib","/CP070909_VMw.zip/metadata.zip/vendor-index.xml","/CP070909_VMw.zip/metadata.zip/vmware.xml","/CP070909_VMw.zip/metadata.zip/vibs/CP070909-3650224511072593898.xml","/CP070909_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070909_HPG3.4-8.0.0.20613240.xml"],"Name":"CP070909.zip","SHA1Sum":"de0967bb06664cd4ced8a8481234bc7cffe2cdd2","SHA256Sum":"ead59706ea2540add06539a03007509499b86c5a180fe8e08cf96c2c96190cc2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070909","Version":"HPG3.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a89f4e51e04040aa83574f9aa1","SupportedDevices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-a_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR416i-a_Gen10P_52.38.3-6909_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.38.3-6909"}]},"Files":[{"Checksum":[{"Filename":"HPE_MR416i-a_Gen10P_52.38.3-6909_A.fwpkg","SHA1Sum":"6f1c78b698b40d6861cbd1f0327597d8f12ad0b9","SHA256Sum":"2339e6a8ea133b94f79871d941fdd39f0bc751c088c077f0c798ab6e119d063b","SHA512Sum":"cb438e1a78d5957084e25fbb6df840b219050a87cdf53cbb54c02a2450ce6a8dd75bad6246e460dea22e97a23e354e5fcb92bbd5b1062980fba7863173e06acc"}],"ComponentSizeInKB":7347,"CompsigList":[],"FileList":["HPE_MR416i-a_Gen10P_52.38.3-6909_A.HPb","HPE_MR416i-a_Gen10P_52.38.3-6909_A.xml","payload.json"],"Name":"HPE_MR416i-a_Gen10P_52.38.3-6909_A.fwpkg","SHA1Sum":"6f1c78b698b40d6861cbd1f0327597d8f12ad0b9","SHA256Sum":"2339e6a8ea133b94f79871d941fdd39f0bc751c088c077f0c798ab6e119d063b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032a"],"TypeOfChange":"1","Version":"52.38.3-6909"}],"InstallationDependency":{},"MinimumActiveVersion":"52.26.3.5487","Name":"Firmware Package - HPE MR416i-a Gen10 Plus Tri Mode Controller","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"032A1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c343a079b3464b2a8b538f00b5","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","A43","A43","A42","U60","U46","U61","A59","U84","A72","U64","U48"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Files":[{"Checksum":[{"Filename":"CP070837.zip","SHA1Sum":"24b45e9f8c2de8d1509bddd1b01931e613f4c4cc","SHA256Sum":"9b33e83409cdf472ca25bc1d91fd48c47a3876166468294b43a30a3c45b2969a","SHA512Sum":"3047e0ecdf8f6401590fe8dc14960f56f215a36c45c94a437ac374cfb5acb5d0e59deb0c415832839768d2d93675b6ca95745be9fb1de4445d08117358946cae"}],"ComponentSizeInKB":18140,"CompsigList":["CP070837.compsig"],"FileList":["/CP070837_BUILD_3.data","/CP070837.vmexe64","/CP070837.vmfile","/CP070837_VMw.zip","/CP070837.xml","/payload.json","/CP070837_VMw.zip/index.xml","/CP070837_VMw.zip/vendor-index.xml","/CP070837_VMw.zip/metadata.zip","/CP070837_VMw.zip/vib20/CP070837/HPE_bootbank_CP070837_4ICRHPK3.3-8.0.0.20613240.vib","/CP070837_VMw.zip/metadata.zip/vendor-index.xml","/CP070837_VMw.zip/metadata.zip/vmware.xml","/CP070837_VMw.zip/metadata.zip/vibs/CP070837-4626515825514893688.xml","/CP070837_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070837_4ICRHPK3.3-8.0.0.20613240.xml"],"Name":"CP070837.zip","SHA1Sum":"24b45e9f8c2de8d1509bddd1b01931e613f4c4cc","SHA256Sum":"9b33e83409cdf472ca25bc1d91fd48c47a3876166468294b43a30a3c45b2969a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3","VibList":[{"Name":"CP070837","Version":"4ICRHPK3.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_96311744a0b246349db25dab30","SupportedDevices":["4d2340a5-304f-3630-3430-304b57565641","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3330-3230-304b57565556","562340a5-304f-3230-3030-304b57565643","4d2340a5-304f-3130-3630-304b57565555"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GWXFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757584646","Version":"HPG3"},{"DeviceName":"MK000960GWXFH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757584648","Version":"HPG3"},{"DeviceName":"MK001920GWXFK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475758464b","Version":"HPG3"},{"DeviceName":"MK003840GWXFL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K503HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475758464c","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068637.exe","SHA1Sum":"4cdf59dcb6a950cd956af4e0e8ffff8bd953a0c4","SHA256Sum":"a8e84d46bac7e538737a7d41fb77cc8eb427ad8f35ffcecfeee63d6fbe5cc5db","SHA512Sum":"b876a4ef911a16a2cd2586962b82cb35a4432cf0fb2e88b787317a2f198bdf3ae05cc8f2e3909b81422cd463a55b78536a6b2e54c88b03fa870f11dc229f3c3f"}],"ComponentSizeInKB":7484,"CompsigList":["cp068637.compsig"],"FileList":["cp068637.xml","cpqsetup.exe","K503HPG3.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068637.exe","SHA1Sum":"4cdf59dcb6a950cd956af4e0e8ffff8bd953a0c4","SHA256Sum":"a8e84d46bac7e538737a7d41fb77cc8eb427ad8f35ffcecfeee63d6fbe5cc5db","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-304757584646","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3330-3834-30475758464c"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GWXFF, MK000960GWXFH, MK001920GWXFK and MK003840GWXFL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GWXFF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWXFH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWXFK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWXFL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3b227ec4622c46b1a335f928e0","SupportedDevices":["4d2340a5-304b-3330-3834-30475758464c","4d2340a5-304b-3130-3932-30475758464b","4d2340a5-304b-3030-3936-304757584648","4d2340a5-304b-3030-3438-304757584646"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"cp068646.exe","SHA1Sum":"c2d5c0dff623eca4cbc4b2692e2c856362d96661","SHA256Sum":"0de0c680e1af08b3a0a0e01165b231eec2f8302a54a0e24ba379c076ca1071d1","SHA512Sum":"579567c9177fb6685fa36d463c5222f2b22f1fcddaea7536f62fce1dfb63d06cdea50cab53cd8cb25c26c943f9a45a35311451c44b073b9a1adeff267745052b"}],"ComponentSizeInKB":4326,"CompsigList":["cp068646.compsig"],"FileList":["cp068646.xml","cpqsetup.exe","KACM6ALSGPK8.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068646.exe","SHA1Sum":"c2d5c0dff623eca4cbc4b2692e2c856362d96661","SHA256Sum":"0de0c680e1af08b3a0a0e01165b231eec2f8302a54a0e24ba379c076ca1071d1","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_40522dcb139844feadb9548f07","SupportedDevices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"cp068653.exe","SHA1Sum":"ec8140c31ab69e09487811a2b32576841b5f3a35","SHA256Sum":"fa56b2951d63bd48e23d3d92b32fe35a74ddb4b6c3c0d69ca662a8306ad9d885","SHA512Sum":"94f814c719229efc9db1bb4e8e6628ad23d82b79912d107a169280ef561c02518fecf3f3515920688fcceb3b1d854ac2c91d46b787ce056b477e987b500898bc"}],"ComponentSizeInKB":4236,"CompsigList":["cp068653.compsig"],"FileList":["cp068653.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SSKYBT512ND9.rel"],"Name":"cp068653.exe","SHA1Sum":"ec8140c31ab69e09487811a2b32576841b5f3a35","SHA256Sum":"fa56b2951d63bd48e23d3d92b32fe35a74ddb4b6c3c0d69ca662a8306ad9d885","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_189d6977f8aa4eb9928f0801d6","SupportedDevices":["452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp073058.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.216"}]},"Files":[{"Checksum":[{"Filename":"cp073060.exe","SHA1Sum":"088945dddbca7e66b1b9065c0d494124cb124127","SHA256Sum":"e48754c86429b1f2b72ec09e18c63de1f87847f2ecbbee910f9ec7784183dee1","SHA512Sum":"7dc5540bd0b30b46907163338ac0fd6de7b21f04661fd51708ef02e8c42728b1cfdf02d458fdaffc9c303c95c649e1440bb8962e7de9718bc544802eb21a3c8a"}],"ComponentSizeInKB":2587,"CompsigList":["cp073060.compsig"],"FileList":["cp073058.compsig","cp073058.zip","cp073060.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp073060.exe","SHA1Sum":"088945dddbca7e66b1b9065c0d494124cb124127","SHA256Sum":"e48754c86429b1f2b72ec09e18c63de1f87847f2ecbbee910f9ec7784183dee1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.216"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE MicroServer Gen10 Plus","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e0030b8a0d144450aedbdf1415","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["FTP","U48"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072275.exe","SHA1Sum":"276121fdf15a34775164bcccc692b3ec36714613","SHA256Sum":"46247ed889989b052ebe958024c4843a9ce191bdf8a3463bb49ec1d3cdea3abf","SHA512Sum":"7c061ab062b26a39e36bd5239ce8ed6ba65ce53d8346ad1bba944d1405631ff31e1882c77660d877ddfbbcf1e8390df8bbf25006d6253fa0c4777cb96caba1f5"}],"ComponentSizeInKB":1406,"CompsigList":["cp072275.compsig"],"FileList":["cp072275.xml","cpqsetup.exe","cp_data.xml","iavf68.cat","iavf68.din","iavf68.inf","iavf68.sys","iavfmsg.dll","install.xml","manifest_iavf68.man","nicdrvr.dll"],"Name":"cp072275.exe","SHA1Sum":"276121fdf15a34775164bcccc692b3ec36714613","SHA256Sum":"46247ed889989b052ebe958024c4843a9ce191bdf8a3463bb49ec1d3cdea3abf","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec76b7ab5a"],"TypeOfChange":"1","Version":"1.19.113.0"}],"InstallationDependency":{},"Name":"HPE Intel iavf Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"iavf68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_83591aa086f940bc9c6f7bd269","SupportedDevices":["a6b1a447-382a-5a4f-8086-37CD15900000","a6b1a447-382a-5a4f-8086-37cd80860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-154c103c0000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-ice-2.6.6-1.rhel10u1.x86_64.rpm","SHA1Sum":"b521de8a97bfafc87298467022af207f9b02c30d","SHA256Sum":"d87c3936c70decc285e4dab403e17fae9f2b5cd3c7a79c7e4238404f366c0c88","SHA512Sum":"f1865d740b6de06387fc59c57af007744635698f3d092225d26f309955143372a04c949280e2219ea701d4507c1fbd0479df30db73a902997576adc35a3529a6"}],"ComponentSizeInKB":1180,"CompsigList":["kmod-ice-2.6.6-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ice.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/ice/ice.ko","./usr/share/doc/kmod-ice","./usr/share/doc/kmod-ice/COPYING","./usr/share/doc/kmod-ice/README","./usr/share/doc/kmod-ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"Name":"kmod-ice-2.6.6-1.rhel10u1.x86_64.rpm","SHA1Sum":"b521de8a97bfafc87298467022af207f9b02c30d","SHA256Sum":"d87c3936c70decc285e4dab403e17fae9f2b5cd3c7a79c7e4238404f366c0c88","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.6.6-1"},{"Checksum":[{"Filename":"kmod-ice-2.6.6-1.rhel10u2.x86_64.rpm","SHA1Sum":"cfc622403682de1dabe59403eec11795d15bcb72","SHA256Sum":"250a8d31aa76f0d0f1755e9d05a1dfde57d4e954ca5ff6c3989bb49b7e9dfbd0","SHA512Sum":"4223a39547f8a91348b74ea0ec343cae8d583955ae7fc138f1c12ce828e73e407704072a185e45519c7bc089245ebe20c821b1686c7d2a333141b0b43ef11fbb"}],"ComponentSizeInKB":1180,"CompsigList":["kmod-ice-2.6.6-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-ice.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/6.12.0-211.7.1.el10_2.x86_64/extra/ice/ice.ko","./usr/share/doc/kmod-ice","./usr/share/doc/kmod-ice/COPYING","./usr/share/doc/kmod-ice/README","./usr/share/doc/kmod-ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"Name":"kmod-ice-2.6.6-1.rhel10u2.x86_64.rpm","SHA1Sum":"cfc622403682de1dabe59403eec11795d15bcb72","SHA256Sum":"250a8d31aa76f0d0f1755e9d05a1dfde57d4e954ca5ff6c3989bb49b7e9dfbd0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.6.6-1"}],"InstallationDependency":{},"Name":"Intel ice Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_76271aff95c6420cb01615efee","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-579e80860001","a6b1a447-382a-5a4f-8086-579E80860000","a6b1a447-382a-5a4f-8086-12d380860007","a6b1a447-382a-5a4f-8086-124a80860001","a6b1a447-382a-5a4f-8086-124a80860008","a6b1a447-382a-5a4f-8086-124a80860004","a6b1a447-382a-5a4f-8086-124a80860002","a6b1a447-382a-5a4f-8086-124980860002","a6b1a447-382a-5a4f-8086-124980860005"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070846.zip","SHA1Sum":"744f21b9a12f17deaa2c9f89fe29da860f5c5fcc","SHA256Sum":"3bd9b2167e9f7f414d1adb607d46e0e32eef2714abf241ea633632c25f1dae94","SHA512Sum":"074be49c32867591ea9cdc9cd0a1d221fef422f130e2e51efd218561d311fe75e46db2725b0ea953421885d4c55af75b9776e3df94a698caab46f48d7c825d51"}],"ComponentSizeInKB":119,"CompsigList":["cp070846.compsig"],"FileList":["/cp070846.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/vib20/igbn/INT_bootbank_igbn_1.13.2.0-1OEM.900.0.24580437.vib","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vendor-index.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vmware.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/vibs/igbn-831206253632276349.xml","/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.zip/metadata.zip/bulletins/Intel-igbn_1.13.2.0-1OEM.900.0.24580437.xml"],"Name":"cp070846.zip","SHA1Sum":"744f21b9a12f17deaa2c9f89fe29da860f5c5fcc","SHA256Sum":"3bd9b2167e9f7f414d1adb607d46e0e32eef2714abf241ea633632c25f1dae94","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd203bbc1","20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"igbn","Version":"1.13.2.0-1OEM.900.0.24580437"}]}],"InstallationDependency":{},"Name":"HPE Intel igbn Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"igbn:1.13.2.0-1OEM.900.0.24580437","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_69e604474754449c9774e704fe","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","A58","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.70 (08/20/2026)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.70 (08/20/2026)"}]},"Files":[{"Checksum":[{"Filename":"U64_2.70_08_20_2026.fwpkg","SHA1Sum":"bce29c19403af0beef654232aaf3667af11185b0","SHA256Sum":"e6fdece3986128084f50eb684c57d7f10d76934f3a0fbfd0bb260a685e56dca6","SHA512Sum":"8d23158b50805e6a4dc531bfaf7a2c1576ab5bd7f91a766fcc484111a02a3bd257bf59bc9942c6d04662d6932dc9fc5ddad456f6889b648927923c3cb962303d"}],"ComponentSizeInKB":16420,"CompsigList":[],"FileList":["payload.json","U64_2.70_08_20_2026.signed.flash","U64_2.70_08_20_2026.xml"],"Name":"U64_2.70_08_20_2026.fwpkg","SHA1Sum":"bce29c19403af0beef654232aaf3667af11185b0","SHA256Sum":"e6fdece3986128084f50eb684c57d7f10d76934f3a0fbfd0bb260a685e56dca6","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.70_08-20-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bd091593b3b04e3684b9f81712","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U64"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070566.exe","SHA1Sum":"92355eab30f42ffb9ac51aaaef09bc9bf1f5718f","SHA256Sum":"cd627b4e8c4fdd69357d68ec323f4fe2229429f7ae08b0aa30b2d291db14cc69","SHA512Sum":"78965fb6056bcaad72253502110b8a440b1934b12f8b7dfdd20ccfb79ddcf88af2afef9d0e978f94a5d579c3538a78bd99c6b3e6e0f59741fd656b9d1e09fb25"}],"ComponentSizeInKB":834,"CompsigList":["cp070566.compsig"],"FileList":["cp070566.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs.cat","vxs.inf","vxs.sys","vxsmsg.dll"],"Name":"cp070566.exe","SHA1Sum":"92355eab30f42ffb9ac51aaaef09bc9bf1f5718f","SHA256Sum":"cd627b4e8c4fdd69357d68ec323f4fe2229429f7ae08b0aa30b2d291db14cc69","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"TypeOfChange":"1","Version":"2.3.7.0"}],"InstallationDependency":{},"Name":"HPE Intel vxs Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"vxs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\vxs.inf_amd64_d6120d6ae1cc028c"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2fe26351e0574dc19e3b9b2986","SupportedDevices":["a6b1a447-382a-5a4f-8086-1565159000d1","a6b1a447-382a-5a4f-8086-1565159000d2"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-7b5e8400dd_1.27-2.1_amd64.deb","SHA1Sum":"d1cab569ca6d68dc6e6fc8b69c25550417b05a26","SHA256Sum":"503c3adee4b322819a8501912c43575677fb5608e453cf6e2b67e63c16777ab6","SHA512Sum":"0b5d6d226cffed111fe2d3ce03a5267b909efc09f5bea65835224bc5c600d8a0c0d051c722bbac4d2ec4415ad966510579471d18c41f6a759391126db37ac2d4"}],"ComponentSizeInKB":3255,"CompsigList":["firmware-smartarray-7b5e8400dd_1.27-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/CP071700.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/Capitola-Release-1.27.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071700.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071700.scexe"],"Name":"firmware-smartarray-7b5e8400dd_1.27-2.1_amd64.deb","SHA1Sum":"d1cab569ca6d68dc6e6fc8b69c25550417b05a26","SHA256Sum":"503c3adee4b322819a8501912c43575677fb5608e453cf6e2b67e63c16777ab6","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Ubuntu – HPE Apollo 2000 Gen10 Plus Backplane Expander FW","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_85e49e85ca434469899db308f7","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":true,"SupportedProducts":["U47","U47","A46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069562.exe","SHA1Sum":"cfe422f523e8126666565d08b4eec0bf12fca554","SHA256Sum":"77d97e35082bd43a7f06e38b6f57b0f0a2b343f58a6f7e09577425d332584895","SHA512Sum":"c889ed512af65793c982f1bd760fad6492744c0db798e182b3ecb5ecbbc5a2bde3fc8b5f9a983d22b69578026a071321fcd4139798fc67ca46e33f5a9a8598e3"}],"ComponentSizeInKB":3381,"CompsigList":["cp069562.compsig"],"FileList":["bcm10ginstaller.dll","bnxfcdo.sys","bnxfcdo_release.txt","bxfcoe.cat","bxfcoe.inf","bxfcoe.sys","bxfcoeco.dll","bxfcoe_release.txt","bxnd.cat","bxnd.inf","bxnd60a.sys","bxois.cat","bxois.inf","bxois.sys","bxoisco.dll","bxois_release.txt","cp069562.xml","cpqsetup.exe","cp_data.xml","evbd.cat","evbd.inf","evbda.sys","install.xml","QLogic_slipstream.zip","qnxcdo.sys","qnxcdo_release.txt"],"Name":"cp069562.exe","SHA1Sum":"cfe422f523e8126666565d08b4eec0bf12fca554","SHA256Sum":"77d97e35082bd43a7f06e38b6f57b0f0a2b343f58a6f7e09577425d332584895","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9bc6b74c"],"TypeOfChange":"1","Version":"7.13.221.0"}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Drivers for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"evbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4cf57e3d1f7b41a89f2a4e1fbd","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ad103c2231"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U39","J10","U40"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.31"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.31"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.31"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.31"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.31"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.31"}]},"Files":[{"Checksum":[{"Filename":"cp072521.exe","SHA1Sum":"eba2e234dddd2167c0aa3e8fba842ef3aeedb55d","SHA256Sum":"8d4b6fdfa58b5901c8ee183a2a7ec0ac104e58e774c86cf9f36da98733e6427d","SHA512Sum":"5e1fd3cbb15b7af08703a6afd5d973096509f3e9cd70e0c0075ca57bb98e6385245dc1647176d1e801efc342a129f06578410bd6503fca48d5ea74ad016e6312"}],"ComponentSizeInKB":3063,"CompsigList":["cp072521.compsig"],"FileList":["cp072521.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.65.31.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp072521.exe","SHA1Sum":"eba2e234dddd2167c0aa3e8fba842ef3aeedb55d","SHA256Sum":"8d4b6fdfa58b5901c8ee183a2a7ec0ac104e58e774c86cf9f36da98733e6427d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"5.3.8.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","SWKey":"qevbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.37.37.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLBBFWUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_305550f1fdb44572b1d105d469","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GWTSV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-304757545356","Version":"HPG7"},{"DeviceName":"VK000480GWTTA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757545441","Version":"HPG7"},{"DeviceName":"VK000960GWTTB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757545442","Version":"HPG7"},{"DeviceName":"VK001920GWTTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757545443","Version":"HPG7"},{"DeviceName":"VK003840GWTTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757545444","Version":"HPG7"},{"DeviceName":"MK000480GWTTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757545448","Version":"HPG7"},{"DeviceName":"MK000960GWTTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475754544b","Version":"HPG7"},{"DeviceName":"MK001920GWTTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475754544c","Version":"HPG7"},{"DeviceName":"MK003840GWTTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYRHPG7.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475754544e","Version":"HPG7"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c566d63ca0-HPG7-6.1.x86_64.rpm","SHA1Sum":"860c1aa2ec2b50bc8842395e7b15a4215466b410","SHA256Sum":"1840c6ca0deeaf1933ed0fbc31f3a91af570711f63889d0e4dafbfa6522c88ec","SHA512Sum":"24b404cab93c42ff2c4e75623b2f73289702a9e13a3cc1dceb282be89a66f9452f0707a31781b2d7441cbacb4d40d292f13e27e841cefca82385e9fecb22a17e"}],"ComponentSizeInKB":5179,"CompsigList":["firmware-hdd-c566d63ca0-HPG7-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/4IYRHPG7.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/CP068904.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c566d63ca0-HPG7-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068904.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068904.scexe"],"Name":"firmware-hdd-c566d63ca0-HPG7-6.1.x86_64.rpm","SHA1Sum":"860c1aa2ec2b50bc8842395e7b15a4215466b410","SHA256Sum":"1840c6ca0deeaf1933ed0fbc31f3a91af570711f63889d0e4dafbfa6522c88ec","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-304757545356","562340a5-304b-3030-3438-304757545441","562340a5-304b-3030-3936-304757545442","562340a5-304b-3130-3932-304757545443","562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3030-3438-304757545448","4d2340a5-304b-3030-3936-30475754544b","4d2340a5-304b-3130-3932-30475754544c","4d2340a5-304b-3330-3834-30475754544e"],"TypeOfChange":"1","Version":"HPG7"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWTSV, VK000480GWTTA, VK000960GWTTB, VK001920GWTTC, VK003840GWTTD, MK000480GWTTH, MK000960GWTTK, MK001920GWTTL and MK003840GWTTN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GWTSV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWTTA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTTB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTTC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTTD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWTTH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWTTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWTTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GWTTN","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7ad7b70347e749eb8fa34cb98f","SupportedDevices":["562340a5-304b-3330-3834-304757545444","4d2340a5-304b-3330-3834-30475754544e","562340a5-304b-3130-3932-304757545443","4d2340a5-304b-3130-3932-30475754544c","562340a5-304b-3030-3936-304757545442","4d2340a5-304b-3030-3936-30475754544b","562340a5-304b-3030-3438-304757545441","4d2340a5-304b-3030-3438-304757545448","562340a5-304b-3030-3234-304757545356"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"CP070938.zip","SHA1Sum":"911fc9e15f700361d2fcd3768c321a0d54057a41","SHA256Sum":"3f62e06a69cfc529632a83021c86d0c4571f9f7b1a4f22966ff036652ba87162","SHA512Sum":"ccdd7efa9d89c14097f602a2ebea807e4bfcb5bcbca4960130ff93e2c42df9ba03a2633140ff90401da2479caed431d8faf8d7dae0590ace9050e1ab7f9f0c4d"}],"ComponentSizeInKB":19779,"CompsigList":["CP070938.compsig"],"FileList":["/CP070938_BUILD_4.data","/CP070938.vmexe64","/CP070938.vmfile","/CP070938_VMw.zip","/CP070938.xml","/payload.json","/CP070938_VMw.zip/index.xml","/CP070938_VMw.zip/vendor-index.xml","/CP070938_VMw.zip/metadata.zip","/CP070938_VMw.zip/vib20/CP070938/HPE_bootbank_CP070938_HPD2.4-8.0.0.20613240.vib","/CP070938_VMw.zip/metadata.zip/vendor-index.xml","/CP070938_VMw.zip/metadata.zip/vmware.xml","/CP070938_VMw.zip/metadata.zip/vibs/CP070938-4885375148488135081.xml","/CP070938_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070938_HPD2.4-8.0.0.20613240.xml"],"Name":"CP070938.zip","SHA1Sum":"911fc9e15f700361d2fcd3768c321a0d54057a41","SHA256Sum":"3f62e06a69cfc529632a83021c86d0c4571f9f7b1a4f22966ff036652ba87162","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2","VibList":[{"Name":"CP070938","Version":"HPD2.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi -MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4fc4092bc1fb4b8392c7b9be08","SupportedDevices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM893.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-abd133f0de_0HPG1-2.1_amd64.deb","SHA1Sum":"8ad0d130d68affb7fadc15b370960366ecc8e020","SHA256Sum":"c093a99faf5dfc13354d736202eef25a9b3fa5629a015af6ea61abb9f17c6a7e","SHA512Sum":"c12afaac06bc960b9e31d24704965b4a276c642efa60507673de6eab36354ab6bbdee870012f7d6f3ead165a54162d5d1bfaeeb061bdcb73401fa072bf79e035"}],"ComponentSizeInKB":5082,"CompsigList":["firmware-hdd-abd133f0de_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/CP071810.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/HPG1PM893.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071810.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071810.scexe"],"Name":"firmware-hdd-abd133f0de_0HPG1-2.1_amd64.deb","SHA1Sum":"8ad0d130d68affb7fadc15b370960366ecc8e020","SHA256Sum":"c093a99faf5dfc13354d736202eef25a9b3fa5629a015af6ea61abb9f17c6a7e","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1f67021e4f1d49838ef1fc29ea","SupportedDevices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U56_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U56_2.70_08_19_2026.fwpkg","SHA1Sum":"4882b958a7b5a131d5795fb2ecd33c46b18dc9a9","SHA256Sum":"6e78bc6098b5f8cfb7edc696595b29f2f686a82d4155b85d1f26a18a0cc89617","SHA512Sum":"5cc0b0342eccab445b81b4926be5474c794fda7291b827a818adb3af22a52c06aa8e33a74d089a0d06ac8371dbe5da06ecc23a31a87567ef6043d088321233eb"}],"ComponentSizeInKB":32816,"CompsigList":[],"FileList":["payload.json","U56_2.70_08_19_2026.signed.flash","U56_2.70_08_19_2026.xml"],"Name":"U56_2.70_08_19_2026.fwpkg","SHA1Sum":"4882b958a7b5a131d5795fb2ecd33c46b18dc9a9","SHA256Sum":"6e78bc6098b5f8cfb7edc696595b29f2f686a82d4155b85d1f26a18a0cc89617","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000239"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE DL110 Gen10 Plus Telco (U56) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U56","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5feb23c65deb46ff8cdb306f96","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U56","FTP"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070110.zip","SHA1Sum":"12aee9c789b6e34b2b2b499ae7c6d7c583196d9d","SHA256Sum":"2abaecd4753503aae231a7810c3dd7ad4d6400f864889b86c876166da27c92d4","SHA512Sum":"d2f3e8da7bc8a1610f8bd9c47f182fe648daa75feee43eb0039c0107f7a22903a82a231c474d7059e2b93df1d91efb35d9d72e35572b388252231d0c823c4139"}],"ComponentSizeInKB":5696,"CompsigList":["cp070110.compsig"],"FileList":["/cp070110.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedf/QLC_bootbank_qedf_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedi/QLC_bootbank_qedi_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedf-686432869232018140.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedi-5880836182664745913.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedentv-6528860809003751673.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedrntv-4334621844710657275.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.xml"],"Name":"cp070110.zip","SHA1Sum":"12aee9c789b6e34b2b2b499ae7c6d7c583196d9d","SHA256Sum":"2abaecd4753503aae231a7810c3dd7ad4d6400f864889b86c876166da27c92d4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"qedi","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.90.2-1OEM.800.1.0.20613240"},{"Name":"qedf","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.90.2-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.420.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedi:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedf:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b512340daadb4de6affb7413b3","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","U46","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-bdfb8e99d9-HPD9-2.1.x86_64.rpm","SHA1Sum":"0a6fa7ab81b025a3681bc05cac8ff5c3b3fe7c40","SHA256Sum":"2d218a9cbcc865581237ece8c2821acdffa82be92b319e7bb29618ebf9dbefce","SHA512Sum":"1367d5b1bdddff5c6364f58573288d87651949b8c1cb837adb99a002679f29ada8dc6dfa24e7be148ba7209ff07ac6cf9d526303d0dbab126d88a1ba7f341656"}],"ComponentSizeInKB":6090,"CompsigList":["firmware-hdd-bdfb8e99d9-HPD9-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/CP068926.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/SSKYBT512ND9.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-bdfb8e99d9-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068926.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068926.scexe"],"Name":"firmware-hdd-bdfb8e99d9-HPD9-2.1.x86_64.rpm","SHA1Sum":"0a6fa7ab81b025a3681bc05cac8ff5c3b3fe7c40","SHA256Sum":"2d218a9cbcc865581237ece8c2821acdffa82be92b319e7bb29618ebf9dbefce","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_241ac77ec9144d9c9a5d27ff91","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072211.exe","SHA1Sum":"b989fb18b400175bd481bc80740b60c51143dafc","SHA256Sum":"b4b797450b7fbc9deb5d90912089d78b1c824b5cee06af7142f02fa957018ae6","SHA512Sum":"666df95e30d30d5bffbffb3bc9ed130eb35b5c1edb46005fb8ec69b52ac881a2899035c16e1696448c8aa36814d6fb927983f252a741b29f3e522ff2e51381ed"}],"ComponentSizeInKB":624,"CompsigList":["cp072211.compsig"],"FileList":["cp072211.xml","cpqsetup.exe","genericmsi.dll","nvmeejectfix5.msi","nvmefix5.cab"],"Name":"cp072211.exe","SHA1Sum":"b989fb18b400175bd481bc80740b60c51143dafc","SHA256Sum":"b4b797450b7fbc9deb5d90912089d78b1c824b5cee06af7142f02fa957018ae6","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82a707e7"],"TypeOfChange":"0","Version":"1.1.0.0"}],"InstallationDependency":{},"Name":"NVMe Drive Eject NMI Fix for Intel Xeon Processor Scalable Family for Microsoft Windows 64-bit","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"nvmeejectfix5.dll","SWKeyExpectedPath":"%ProgramFiles%\\nvmefix"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0f87f198423d4d10939ef6b615","SupportedDevices":["a6b1a447-382a-5a4f-8086-2020159000ea"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U36","U41","U33","U40","U39","U37","U38","U38","I43","I42","U45"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-492a9952f6_0HPG5-2.1_amd64.deb","SHA1Sum":"8cda1e6655406b77be6b9b0b6a90fbf8b7306e76","SHA256Sum":"a038657a41d17441c8d469999aadfe56460bcc02cd4523b0904ee562797f4480","SHA512Sum":"c43887d6d33e9dbdc218158087cca64fad51106bd729ae350b31cdb8dc4cc49b3f4398479ea5b99256fdb65c5d80e9294507698f82f986638eedebc5f433f785"}],"ComponentSizeInKB":3505,"CompsigList":["firmware-hdd-492a9952f6_0HPG5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/CP071748.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/K401HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071748.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-492a9952f6-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071748.scexe"],"Name":"firmware-hdd-492a9952f6_0HPG5-2.1_amd64.deb","SHA1Sum":"8cda1e6655406b77be6b9b0b6a90fbf8b7306e76","SHA256Sum":"a038657a41d17441c8d469999aadfe56460bcc02cd4523b0904ee562797f4480","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_105aea76e7234a4898a01ef7c5","SupportedDevices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069545.exe","SHA1Sum":"c498c79eb1547160c6711959e62f3f62de7048e9","SHA256Sum":"2b221c1557aa85cabc16e6d1feb002a2b5f526e102ff0d556887575e26d5524c","SHA512Sum":"6f4b0efef83bd447f33cf183498ea8e36519ef10048bd6cb1fdf47255610dfb91d9b7769915aa8c699b052c198e22ebba81ea2a10677a314da000c0601ff8e8e"}],"ComponentSizeInKB":1054,"CompsigList":["cp069545.compsig"],"FileList":["cp069545.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069545.exe","SHA1Sum":"c498c79eb1547160c6711959e62f3f62de7048e9","SHA256Sum":"2b221c1557aa85cabc16e6d1feb002a2b5f526e102ff0d556887575e26d5524c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.1.24.0"}],"InstallationDependency":{},"Name":"Intel i350 Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755374"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bc3de517782147afa79bbf057e","SupportedDevices":["a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072355.zip","SHA1Sum":"9b7b4e1cffe13f7650b5fdad53820558e87e3581","SHA256Sum":"f486d6f1f329407a58ecc6eba5fba5d42c893fef053ee7dba71273b62b860a43","SHA512Sum":"9f2545bcedef2a8c411760891aa25f8606e05279df1855b3e2ac44617439d55f8032fa96f2f0d68bc66ca75fc8a48b50a792b67b2043cbb8efa88f03ef1b6a01"}],"ComponentSizeInKB":13623,"CompsigList":["cp072355.compsig"],"FileList":["/cp072355.xml","/MIS_bootbank_ssacli2_6.65.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.65.11.0-0.zip","/ssacli2-component_6.65.11.0-0.zip/index.xml","/ssacli2-component_6.65.11.0-0.zip/vendor-index.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip","/ssacli2-component_6.65.11.0-0.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.65.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vmware.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vibs/ssacli2--6784777076922694234.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/bulletins/ssacli2-component_6.65.11.0-0.xml"],"Name":"cp072355.zip","SHA1Sum":"9b7b4e1cffe13f7650b5fdad53820558e87e3581","SHA256Sum":"f486d6f1f329407a58ecc6eba5fba5d42c893fef053ee7dba71273b62b860a43","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"ssacli2","Version":"6.65.11.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 9.1 for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"ssacli2-component:6.65.11.0-0","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.65.11.0-1OEM.900.0.24755229","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a7ff1a6911524f75b9f7126152","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U43","U41","U33","U44","U40","U45","U37","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","U51","A47","A48","U50","U47","A46","U47","A48","U48","U47","U47","U50","U46","I44","U38","U38","U38","U40","U40","U39","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U46","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","P92","P95","P99","U23","O42","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I39","I40","I37","U57","U62","U65","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-6b7ce3da0e-HPG2-14.1.x86_64.rpm","SHA1Sum":"9ca0feb21f5b356d0325483f791f4b720651628e","SHA256Sum":"d74415ef6caf672dc69f1f7adab7e81e5d8be56ccf7ceb317f984582b8d1f871","SHA512Sum":"7b8fae301d646a3fcf71c0ad4caa14a76f24a9ca1c91f88498288844991d542148239599676e01a6ce80d0e2bc9935032e19c2386a651b7757e87f9a2973449a"}],"ComponentSizeInKB":6016,"CompsigList":["firmware-hdd-6b7ce3da0e-HPG2-14.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/CP068930.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/SMOBULABPTG2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-6b7ce3da0e-HPG2-14.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068930.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068930.scexe"],"Name":"firmware-hdd-6b7ce3da0e-HPG2-14.1.x86_64.rpm","SHA1Sum":"9ca0feb21f5b356d0325483f791f4b720651628e","SHA256Sum":"d74415ef6caf672dc69f1f7adab7e81e5d8be56ccf7ceb317f984582b8d1f871","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_550deb8b0471468da76947e52e","SupportedDevices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a05f29cef3-HPDD-4.1.x86_64.rpm","SHA1Sum":"2d9ed8425fecf3dbedf1830b11bd5c90d8e3dafa","SHA256Sum":"fab19de9378e1abc091abef651330298e984a6f6684a8c36167fd680ebdacf97","SHA512Sum":"467e70a9d37db0c1fb0b8ef0f578d0558b4cdd84141435db7208255e09a3b42ff20bca03b93efc5fb937fecf6f1d6b619092571859c0e273e2f27c96b3cbfa29"}],"ComponentSizeInKB":5878,"CompsigList":["firmware-hdd-a05f29cef3-HPDD-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/CP068929.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/SKESTEDD.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068929.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068929.scexe"],"Name":"firmware-hdd-a05f29cef3-HPDD-4.1.x86_64.rpm","SHA1Sum":"2d9ed8425fecf3dbedf1830b11bd5c90d8e3dafa","SHA256Sum":"fab19de9378e1abc091abef651330298e984a6f6684a8c36167fd680ebdacf97","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4d0081a2928643a98e1eabd433","SupportedDevices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"cp068739.exe","SHA1Sum":"f504b1a99ed489c0d59054d9fef246ee33ba9c13","SHA256Sum":"6518d6c36ee3fcd9bf2eb8e64c03d39dc5258b19854754723bd4f9f9045cb357","SHA512Sum":"cf139036ef406edbbe6cb0746349d2f14011ca0f5ce439c4963707e94f193d719cdfa4239851b212eafa2fdeb798ea75c987d55b48dad78d7a210336df4fa00b"}],"ComponentSizeInKB":4262,"CompsigList":["cp068739.compsig"],"FileList":["cp068739.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SLONGSPKESD3.rel"],"Name":"cp068739.exe","SHA1Sum":"f504b1a99ed489c0d59054d9fef246ee33ba9c13","SHA256Sum":"6518d6c36ee3fcd9bf2eb8e64c03d39dc5258b19854754723bd4f9f9045cb357","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB018000JXMTH and MB020000JXMTP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_03a98050888847a781c6cde05e","SupportedDevices":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-ice-2.6.6-1.rhel9u7.x86_64.rpm","SHA1Sum":"07618cdfbf991507a41fb2a21a189167dbeac682","SHA256Sum":"fcfed4fee3ac59fdf450708cdf8c814b7e1e4eff756844f84b4126e3ff6658bd","SHA512Sum":"c94ac3a3aa17c197e23568fbf13273030bea18e37bc2ef4eb5029370be69efa5ac5d5cf8ed96ee48c97c66c5569372d70c69d4fd4810aa918e7fe9d62ada0939"}],"ComponentSizeInKB":1163,"CompsigList":["kmod-ice-2.6.6-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/ice","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/71","./usr/lib/.build-id/71/aef77c633db2ace36e7a818bc8be1fdbce2ffa","./usr/share/doc/ice","./usr/share/doc/ice/COPYING","./usr/share/doc/ice/README","./usr/share/doc/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"Name":"kmod-ice-2.6.6-1.rhel9u7.x86_64.rpm","SHA1Sum":"07618cdfbf991507a41fb2a21a189167dbeac682","SHA256Sum":"fcfed4fee3ac59fdf450708cdf8c814b7e1e4eff756844f84b4126e3ff6658bd","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.6.6-1"},{"Checksum":[{"Filename":"kmod-ice-2.6.6-1.rhel9u8.x86_64.rpm","SHA1Sum":"d0a784dc5039167e154eff957779bb7f3d1ea121","SHA256Sum":"20d592b611923d2b958052af619506e4e280a7eebcecdab56e99be0f1a11bcac","SHA512Sum":"ea524b7029d588d0e5a7d5428b1bfa6c22ed19fd705914b564c86773ff016aa46faec8883e1799dcda1d878be583e9905d34e63c2341212c2f40e1a777cdc435"}],"ComponentSizeInKB":1148,"CompsigList":["kmod-ice-2.6.6-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/ice.conf","./etc/dracut.conf.d/ice-oob.conf","./lib/firmware/updates/intel/ice/ddp/LICENSE","./lib/firmware/updates/intel/ice/ddp/ice-1.3.59.0.pkg","./lib/firmware/updates/intel/ice/ddp/ice.pkg","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/ice","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/ice/ice.ko","./usr/lib/.build-id","./usr/lib/.build-id/17","./usr/lib/.build-id/17/5aa8808f0b50a58e8d94e49d28892d3480ec12","./usr/share/doc/ice","./usr/share/doc/ice/COPYING","./usr/share/doc/ice/README","./usr/share/doc/ice/pci.updates","./usr/share/man/man7/ice.7.gz","./usr/share/smartupdate/kmod-ice/component.xml"],"Name":"kmod-ice-2.6.6-1.rhel9u8.x86_64.rpm","SHA1Sum":"d0a784dc5039167e154eff957779bb7f3d1ea121","SHA256Sum":"20d592b611923d2b958052af619506e4e280a7eebcecdab56e99be0f1a11bcac","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eca436a7e9"],"TypeOfChange":"1","Version":"2.6.6-1"}],"InstallationDependency":{},"Name":"Intel ice Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-ice","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_386d43e38b534bcc872f726cfc","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-15938086000e","a6b1a447-382a-5a4f-8086-12d380860005","a6b1a447-382a-5a4f-8086-579e80860001","a6b1a447-382a-5a4f-8086-579E80860000","a6b1a447-382a-5a4f-8086-12d380860007","a6b1a447-382a-5a4f-8086-124a80860001","a6b1a447-382a-5a4f-8086-124a80860008","a6b1a447-382a-5a4f-8086-124a80860004","a6b1a447-382a-5a4f-8086-124a80860002","a6b1a447-382a-5a4f-8086-124980860002","a6b1a447-382a-5a4f-8086-124980860005"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U47","U45","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","U47","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U77","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM2 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM2_1.24_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"9675b54e-1c96-44c3-a7a1-901502000000","Version":"1.24"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM2_1.24_A.fwpkg","SHA1Sum":"508ce0e13241f66a3f0f518b9b1f7f7ae6731bf3","SHA256Sum":"776e0fd1d10a8e33dcfbca384115097925b68974f476d7d9daf9967646c403b3","SHA512Sum":"81037776b5bafeb1d0624129833c7dac3ebd788d3cde2a6b93bc1f17f55c4acef6bc47943a340dc344f51131f9c021516bd9046ee775226735b120cf0cf849b8"}],"ComponentSizeInKB":56,"CompsigList":[],"FileList":["HPE_UBM2_1.24_A.HPb"],"Name":"HPE_UBM2_1.24_A.fwpkg","SHA1Sum":"508ce0e13241f66a3f0f518b9b1f7f7ae6731bf3","SHA256Sum":"776e0fd1d10a8e33dcfbca384115097925b68974f476d7d9daf9967646c403b3","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901502000000"],"TypeOfChange":"1","Version":"1.24"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.22.3-4597 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR416i-o/SR932i-p controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus/Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4597"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.22.3 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.22.3-4650"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 SR308i-o/SR308i-p controller firmware version 5.32 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.32"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus Controller firmware version 03.01.14.062 or greater is required and should be already active for firmware update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.14.062"}]}]}]},"Name":"Firmware Package - UBM2 Backplane PIC PLDM Firmware for Gen10/Gen10P/Gen11 Servers/Gen12 servers usage","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM2PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f81b94ee382e489eaba675dd29","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","7.0","12.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U54","U54","U63","U58","U46","U46","A43","A43","A43","U50","A42","U61","U60","U46","U68","U68","U71","U71"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068734.exe","SHA1Sum":"44e80f8d3e3c47d83a932cccebd85748a9b968ed","SHA256Sum":"f8760e07694a1dd4c515f4962a56ec9d369998810083167f6307ebfeebaf6e14","SHA512Sum":"afd777b1ebc37a7e3b0c913d958d608f8a264f98c544b543ce0933671576d063a88a18a1d2dd61faae5cdafa1c18bcbcf8362a5e395b5079e8a5e2f953ceeee7"}],"ComponentSizeInKB":4263,"CompsigList":["cp068734.compsig"],"FileList":["cp068734.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVANSSD4.rel"],"Name":"cp068734.exe","SHA1Sum":"44e80f8d3e3c47d83a932cccebd85748a9b968ed","SHA256Sum":"f8760e07694a1dd4c515f4962a56ec9d369998810083167f6307ebfeebaf6e14","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_27683fdd56684a358c88bdcb0e","SupportedDevices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-aef2a690c9-HPG5-13.1.x86_64.rpm","SHA1Sum":"23a48311e02dd55e4e81e78baeda38cef4aacbc7","SHA256Sum":"06c0a19d1abcc106cc8ef5a8301f16a0c89a70b569db53d309e1d158293c449d","SHA512Sum":"4333f33fe66a9d028b3f278e5766919a2c5abbdf05f651e91d9a265ff4d241d841b391a784380f76a21e32bc29e14ff3493bcd7414da84c1ae096cd4c46ff8e0"}],"ComponentSizeInKB":4414,"CompsigList":["firmware-hdd-aef2a690c9-HPG5-13.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/CP068905.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068905.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068905.scexe"],"Name":"firmware-hdd-aef2a690c9-HPG5-13.1.x86_64.rpm","SHA1Sum":"23a48311e02dd55e4e81e78baeda38cef4aacbc7","SHA256Sum":"06c0a19d1abcc106cc8ef5a8301f16a0c89a70b569db53d309e1d158293c449d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_89e45fac4c3a461283ecd1b976","SupportedDevices":["4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3130-3932-3047574a5048","4d2340a5-304b-3030-3234-3047574b564b","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3330-3834-3047574a504b","4d2340a5-304b-3030-3438-3047574a504e","562340a5-304b-3030-3438-3047574a5045","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3030-3936-3047574a5046"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"4149ebb7-d64b-4654-b679-4280f349ea50","Devices":{"Device":[{"DeviceName":"UBM1 Backplane PIC","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_UBM1_1.50_B.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"9675b54e-1c96-44c3-a7a1-901501000000","Version":"1.50"}]},"Files":[{"Checksum":[{"Filename":"HPE_UBM1_1.50_B.fwpkg","SHA1Sum":"aa69de110882ea44ed24dfc0ffd36fe313874971","SHA256Sum":"3b671d7b8254a139a1ceb158d3da59234bb3c0383f74a290acfc5fbdbd09592c","SHA512Sum":"8544e6267a06663c9a4afd46fde1124944668fe8411d5544b97cfaae827f60a72c7769708cf5bc32203c7e78e4f5705d1c0631bdd2a5d32acaad7a8ab212a5d6"}],"ComponentSizeInKB":72,"CompsigList":[],"FileList":["HPE_UBM1_1.50_B.HPb","HPE_UBM1_1.50_B.xml","payload.json"],"Name":"HPE_UBM1_1.50_B.fwpkg","SHA1Sum":"aa69de110882ea44ed24dfc0ffd36fe313874971","SHA256Sum":"3b671d7b8254a139a1ceb158d3da59234bb3c0383f74a290acfc5fbdbd09592c","SoftwarePlatforms":[],"TargetGUIDs":["9675b54e-1c96-44c3-a7a1-901501000000"],"TypeOfChange":"1","Version":"1.50"}],"InstallationDependency":{},"Name":"Firmware Package - UBM1 Backplane PIC PLDM Firmware","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"UBM1PIC","SWKeyExpectedPath":"firmware:sd:ubm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d10b739117e4429a82a718b116","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","12.0","7.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A43","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","HPE Apollo 2000 Gen10 Plus System","I44"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWRTN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475752544e","Version":"HPG2"},{"DeviceName":"MB012000GWRTL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475752544c","Version":"HPG2"},{"DeviceName":"MB010000GWRTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPTG2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-30475752544b","Version":"HPG2"}]},"Files":[{"Checksum":[{"Filename":"cp068658.exe","SHA1Sum":"2874b0150038b077f4e6a38e04b2dc5b5a18e005","SHA256Sum":"cac170f20d7b045e706ed24e1659f1788be4930024d44725449a246d8529ba86","SHA512Sum":"6c5f37784e184003a1e55cee4bf01d9a9fd1931a95b717e61c854f931b74a8c73c1b6fe7f9aca042ab0e410b81bd0506b4a87f9f704a96fc1ee69441f56c1032"}],"ComponentSizeInKB":4179,"CompsigList":["cp068658.compsig"],"FileList":["cp068658.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SMOBULABPTG2.rel"],"Name":"cp068658.exe","SHA1Sum":"2874b0150038b077f4e6a38e04b2dc5b5a18e005","SHA256Sum":"cac170f20d7b045e706ed24e1659f1788be4930024d44725449a246d8529ba86","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"TypeOfChange":"1","Version":"HPG2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000GWRTN, MB012000GWRTL and MB010000GWRTK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWRTN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWRTL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB010000GWRTK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0055eb2e6f1a4b82856baa2214","SupportedDevices":["4d2340a5-3042-3431-3030-30475752544e","4d2340a5-3042-3231-3030-30475752544c","4d2340a5-3042-3031-3030-30475752544b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVLAWBA0HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ca21e169e2-HPG5-2.1.x86_64.rpm","SHA1Sum":"d098471ce8a62ee2587ba839e665efcf0eaec0f0","SHA256Sum":"798def177d8c78f6fc2bcba360319d141fb82467900e0a7b47b58f8d26b446cb","SHA512Sum":"f2f6e92c22de66a3dadc7014f2d6c1aa63dbf33df236e2f26b9524ac81abdcd332151a45a83ceb9a1e276302d0feec0b652e5fc987e06385cece5ac3080197bd"}],"ComponentSizeInKB":6296,"CompsigList":["firmware-hdd-ca21e169e2-HPG5-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/CP073206.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/WVLAWBA0HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ca21e169e2-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073206.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073206.scexe"],"Name":"firmware-hdd-ca21e169e2-HPG5-2.1.x86_64.rpm","SHA1Sum":"d098471ce8a62ee2587ba839e665efcf0eaec0f0","SHA256Sum":"798def177d8c78f6fc2bcba360319d141fb82467900e0a7b47b58f8d26b446cb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000GWKGV Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_71898064dab04c748b9ac84210","SupportedDevices":["4d2340a5-3042-3430-3030-3047574b4756"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u1.x86_64.rpm","SHA1Sum":"0c7dea8933eab983e86ba83836e8231c7b74c182","SHA256Sum":"6a0e05e4e396433da4f5dba4e019c7713a7782ed6a6274615315b108565c8cab","SHA512Sum":"8709baa620c73ab75843bacf8a62b95778457f06c1fa5419ce9ff94ee672b503122e5ad058e0bfd9a5ba5e1f810d7088a9be4e187f789d25bcd71a18c7d52800"}],"ComponentSizeInKB":2758,"CompsigList":["kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/lib/.build-id","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/7548d4b31e2423b17e226b3ac0379bd0bc3639","./usr/lib/.build-id/0d","./usr/lib/.build-id/0d/2900e9fd035d8d91f101d0b7c4e707dd565fc5","./usr/lib/.build-id/13","./usr/lib/.build-id/13/50b3f3488fd6a731d2d99791b1877bbabc8877","./usr/lib/.build-id/24","./usr/lib/.build-id/24/e6792abf338746ad0942f99a3ade351cdacb29","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/a961a970c43e50f9be03f8133a57ecac30ece4","./usr/lib/.build-id/45","./usr/lib/.build-id/45/0dd756691f6d92d075c2bc45f1d7cd5d82195c","./usr/lib/.build-id/48","./usr/lib/.build-id/48/8d294ed312862acf93e6a40e0ac55c6ed37596","./usr/lib/.build-id/4d","./usr/lib/.build-id/4d/83d2d42f3b4915ca93aec9fd3b8baf3dc91cf7","./usr/lib/.build-id/55","./usr/lib/.build-id/55/27db42e0f3f2c8680ee23d1b520cc90f5c68b7","./usr/lib/.build-id/58","./usr/lib/.build-id/58/9ca6a18b97cf17da851ff93b705998cc8834f9","./usr/lib/.build-id/60","./usr/lib/.build-id/60/a66e0d9a24c4ec8f61a5c4c46b740fc121f621","./usr/lib/.build-id/60/ac67b5788a5d56dea213984d1136b2f7811b02","./usr/lib/.build-id/73","./usr/lib/.build-id/73/aca6043e13126e4674c80680ec1e7f239d58d4","./usr/lib/.build-id/76","./usr/lib/.build-id/76/ae8190ca552a75e99b692288e1e30246cc177a","./usr/lib/.build-id/78","./usr/lib/.build-id/78/47726bbe631136f696f4e730da0f17f5173639","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/06eba570171d3283bf0b1de5a584d0589aa9bf","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/568a1439937da66d73f5223a881f9b47b527ff","./usr/lib/.build-id/8c/9e3f7b7189d77b6796b086c82c36e70623a488","./usr/lib/.build-id/8e","./usr/lib/.build-id/8e/b514b3c88d446275910cc5165edfbdd6f1b5f7","./usr/lib/.build-id/94","./usr/lib/.build-id/94/2b9960de1e00ecba8fccd172f8d3c8ca0fc364","./usr/lib/.build-id/96","./usr/lib/.build-id/96/aa91cd3e37f3a2b327b1d757ffafe8ad13d684","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/7dabc9c0fd44f1417171b00eb2e95f562891e4","./usr/lib/.build-id/b8","./usr/lib/.build-id/b8/6683559f7e9cc3e3cb2d6a9a73db2b0c4f86ed","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/4a37ea09ab94e75a8eaf28762c02094a50bcbd","./usr/lib/.build-id/bd","./usr/lib/.build-id/bd/3f22b80c827c92264ab22b51b5eafaedd565b9","./usr/lib/.build-id/be","./usr/lib/.build-id/be/8ea687d8c33858cfc34697600a90186358b4f0","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/5501b2b9a08eb37602df0f7d944ff69f40a94c","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/d29cbda3708e9fbecc60a68b79b7a8d0d73206","./usr/lib/.build-id/d4","./usr/lib/.build-id/d4/185da50db436bef19f5165757345a328021d35","./usr/lib/.build-id/d7","./usr/lib/.build-id/d7/7b568ebdb8626178a6ca31649f1eee4e199fbf","./usr/lib/.build-id/d9","./usr/lib/.build-id/d9/c7ba5819e9725721b5efaf5d56b854b64ae4be","./usr/lib/.build-id/e4","./usr/lib/.build-id/e4/e41670a17af1b411ed0587c858d85b3306b38b","./usr/lib/.build-id/e5","./usr/lib/.build-id/e5/8c15560c7422ad86a53e34f03cfd3b924f573d","./usr/lib/.build-id/e7","./usr/lib/.build-id/e7/b460ea20448aa65a6cce12c0c8e5969f322e3b","./usr/lib/.build-id/ee","./usr/lib/.build-id/ee/89009c87319a1af4ef176e114a77b9914b6353","./usr/lib/.build-id/f0","./usr/lib/.build-id/f0/d3098487911ee8dfc068fa0c98caeb65a5ea33","./usr/lib/.build-id/f3","./usr/lib/.build-id/f3/46171a5b24c7ca69accd4e438bdec6d6fc7d50","./usr/lib/.build-id/f5","./usr/lib/.build-id/f5/b0ecc1311fc341352125e37d8542f02bfde07c","./usr/lib/.build-id/fc","./usr/lib/.build-id/fc/fe1658382c898dc8ec8d82403cdc42038992fb","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/449874232faa11d41ce038efd430d043a22af6","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"Name":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel10u1.x86_64.rpm","SHA1Sum":"0c7dea8933eab983e86ba83836e8231c7b74c182","SHA256Sum":"6a0e05e4e396433da4f5dba4e019c7713a7782ed6a6274615315b108565c8cab","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u1.x86_64.rpm","SHA1Sum":"7ec36f55051084ea6defdc034d9a64ead2088c74","SHA256Sum":"17d7a572cc79b855d004858ab94e81d52bf1692ffe5758ae96026895bc22c0b7","SHA512Sum":"8e226cef53ee34071f8691d929ea23543c6272a8568fb294b921a6c7135a9b24cf395db119f807cc91272406c787961e68db2905401c1dae9738aefba88f6864"}],"ComponentSizeInKB":1992,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u1.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/02","./usr/lib/.build-id/02/e44353fa850ffd9aa7bb85810373e293fb4e7f","./usr/lib/.build-id/12","./usr/lib/.build-id/12/06539ee0904cf829de0309f963cca7d87987e2","./usr/lib/.build-id/18","./usr/lib/.build-id/18/69a48c0f71c97ea9549a621a335b65695e853e","./usr/lib/.build-id/1a","./usr/lib/.build-id/1a/2e82d2b820a1a913fd5d95ce5761e2fb3e4176","./usr/lib/.build-id/1c","./usr/lib/.build-id/1c/35ea925090feeabe0e2a5d163f9fe655b04bff","./usr/lib/.build-id/2c","./usr/lib/.build-id/2c/440f5567574df7af8855587bc46b58689a074f","./usr/lib/.build-id/2c/966d6358b5acecc83d9890c87d24c2af1b634d","./usr/lib/.build-id/5e","./usr/lib/.build-id/5e/385d753f92aef1a637ec7878741b42d0080d58","./usr/lib/.build-id/80","./usr/lib/.build-id/80/da383987f7cc582a9fcb9fe23434464f856d70","./usr/lib/.build-id/9d","./usr/lib/.build-id/9d/4e8f94e5990b582d39daafc25c0db54042cc23","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/5e99478d4c4c043de8f4aeac9dfc819531fd88","./usr/lib/.build-id/a7","./usr/lib/.build-id/a7/b0c1ae3cfa518477a57da1c88a73f6a4b23e8c","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/22acac57daafbbfcd5b01b060812511e16904c","./usr/lib/.build-id/b9","./usr/lib/.build-id/b9/80b11215e601a3e8f1b6db28731435ac013754","./usr/lib/.build-id/bc","./usr/lib/.build-id/bc/b44092db5ea572f5267751014c44525dccdc82","./usr/lib/.build-id/ca","./usr/lib/.build-id/ca/6d55c7d5898beb5eab4d6491aeeb3a9b0ff501","./usr/lib/.build-id/d9","./usr/lib/.build-id/d9/17c74cf52fadfb67b2eed0c095eeefb92fa17b","./usr/lib/.build-id/dc","./usr/lib/.build-id/dc/54705c1e468f44ffef135c4e81e43c795a0b57","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/c7c2b1ba487b6299289ada024edc44132b730b","./usr/lib/.build-id/ed","./usr/lib/.build-id/ed/d9abe05bf048dc95e705d1cede5b6e63d0299f","./usr/lib/.build-id/f2","./usr/lib/.build-id/f2/ad50a9a16131c71b4751c781ee1b9baf220d83","./usr/lib/.build-id/f6","./usr/lib/.build-id/f6/5def2aa440070a9c216922fce9fcb2da27d652","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/mlnx-ofa_kernel","./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/perftest","./usr/share/doc/perftest/COPYING","./usr/share/doc/perftest/README","./usr/share/doc/perftest/runme","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel10u1.x86_64.rpm","SHA1Sum":"7ec36f55051084ea6defdc034d9a64ead2088c74","SHA256Sum":"17d7a572cc79b855d004858ab94e81d52bf1692ffe5758ae96026895bc22c0b7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"Name":"Linux","Value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"Name":"Linux","Value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"Name":"Linux","Value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"Name":"Linux","Value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 10 Update 1 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9c87aa8b9d084acfb0a4160890","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U69","U69","U70","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"CP070836.zip","SHA1Sum":"f6a5c835371f83caf4e4032c03d14b2df58d85eb","SHA256Sum":"ab246757832935e805e158c16b072e09b63449d5f9784d787e8b845f0cf819f8","SHA512Sum":"0f38b03aa36d0f4a69b6fbd39c4851710ab6112aa0e28e64e9e0c53edb9e8dedc286c4e805930fe10ecaf97687c8a59ffbb8722cc2a3903c37b791015699f88d"}],"ComponentSizeInKB":16261,"CompsigList":["CP070836.compsig"],"FileList":["/CP070836_BUILD_5.data","/CP070836.vmexe64","/CP070836.vmfile","/CP070836_VMw.zip","/CP070836.xml","/payload.json","/CP070836_VMw.zip/index.xml","/CP070836_VMw.zip/vendor-index.xml","/CP070836_VMw.zip/metadata.zip","/CP070836_VMw.zip/vib20/CP070836/HPE_bootbank_CP070836_HPG5.5-8.0.0.20613240.vib","/CP070836_VMw.zip/metadata.zip/vendor-index.xml","/CP070836_VMw.zip/metadata.zip/vmware.xml","/CP070836_VMw.zip/metadata.zip/vibs/CP070836--6060580474925906781.xml","/CP070836_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070836_HPG5.5-8.0.0.20613240.xml"],"Name":"CP070836.zip","SHA1Sum":"f6a5c835371f83caf4e4032c03d14b2df58d85eb","SHA256Sum":"ab246757832935e805e158c16b072e09b63449d5f9784d787e8b845f0cf819f8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP070836","Version":"HPG5.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1b1a70ed4f854fe5b5518a7d13","SupportedDevices":["4d2340a5-304b-3130-3932-3047574a5051","4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3330-3834-3047574a504b","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3234-3047574a5044"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072687.zip","SHA1Sum":"1429617b3730f251283bded0c9e277e04de1852f","SHA256Sum":"4d46a070c526a210e9756f9975e252967fd955c34f91e03d71d63e9be3fc3556","SHA512Sum":"37d503372a9e308d26ec58d2291e516a84eb3a6b53e9c53781bee5a60be87904ef1a9b6b347399d9332b76fd570278920ca22f8f1273d8578c2a67a6c1ec75d6"}],"ComponentSizeInKB":383,"CompsigList":["cp072687.compsig"],"FileList":["/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip","/cp072687.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/index.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/vib20/bnxtroce/BCM_bootbank_bnxtroce_238.1.147.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/vib20/bnxtnet/BCM_bootbank_bnxtnet_238.1.147.0-1OEM.900.0.24755229.vib","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtroce-192341177695114936.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/bnxtnet--7805444915192846666.xml","/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Broadcom-bnxt-Net-RoCE_238.1.247.0-1OEM.900.0.24755229.xml"],"Name":"cp072687.zip","SHA1Sum":"1429617b3730f251283bded0c9e277e04de1852f","SHA256Sum":"4d46a070c526a210e9756f9975e252967fd955c34f91e03d71d63e9be3fc3556","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc7b58dd7","20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","20a6e8e4-bf33-4c71-a6bf-d9ec158e843a"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"bnxtroce","Version":"238.1.147.0-1OEM.900.0.24755229"},{"Name":"bnxtnet","Version":"238.1.147.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-bnxt-Net-RoCE:238.1.247.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"bnxtroce:238.1.147.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"bnxtnet:238.1.147.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8d56d4eb74fb4f34803f873d49","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U46","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-12304c1aca_0HPG6-2.1_amd64.deb","SHA1Sum":"5fdbbc738a916f3a737d7bd517d99d3aadb24bba","SHA256Sum":"5c40609ef1d739062eb79c42422145ecc191900c3b2b14dfaf093bbf16fc99f4","SHA512Sum":"695eb05cf2c4e4f34f0299504fc817036734f7089ca54502686853bf14b3b3f34632d77bc0832d06a9872be42e1e23138066885fadbb5de06d073d089db93ce2"}],"ComponentSizeInKB":4125,"CompsigList":["firmware-hdd-12304c1aca_0HPG6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/CP071714.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/SCIMARRNNTG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071714.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-12304c1aca-HPG6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071714.scexe"],"Name":"firmware-hdd-12304c1aca_0HPG6-2.1_amd64.deb","SHA1Sum":"5fdbbc738a916f3a737d7bd517d99d3aadb24bba","SHA256Sum":"5c40609ef1d739062eb79c42422145ecc191900c3b2b14dfaf093bbf16fc99f4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ba0acc28c7684fd7a70ed9c0e3","SupportedDevices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"storcli_007.3811.0300_all.deb","SHA1Sum":"2e14aaea12a1e1cc94d520d224e919316856d6b7","SHA256Sum":"ae5f3d9f6e64e399f71ae0693831b339c00a6c6c0160729d5faf90efcbf49d56","SHA512Sum":"188da0d9fb567e7e76ea1bdf8d59b2b07f0ddc8e0449ff5394f13d8f76c1168b2dafd71ab5ff9210561d5469fe72b66c9fb5233317ac5c21db964f4077146fa0"}],"ComponentSizeInKB":2275,"CompsigList":["storcli_007.3811.0300_all.compsig"],"FileList":["./opt/MegaRAID/storcli/storcli64","./usr/share/smartupdate/storcli/component.xml"],"Name":"storcli_007.3811.0300_all.deb","SHA1Sum":"2e14aaea12a1e1cc94d520d224e919316856d6b7","SHA256Sum":"ae5f3d9f6e64e399f71ae0693831b339c00a6c6c0160729d5faf90efcbf49d56","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"007.3811.0300"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for Ubuntu (for Gen10P and Gen11 Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"storcli","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f295695a8fa546af80d2d5c908","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","A72","U71","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"CP070961.zip","SHA1Sum":"5ea3802c1de14ac33186af4c4d5b3c7c1c12981a","SHA256Sum":"0780c30ae6088fe290d2f25cbe659ac8282391aa4dd65c4c3d7b645bd2568dbf","SHA512Sum":"1142972fe3bb96403eea19e7068e6a4e2fd81f0c3d4750db4e15b4550ddc7ca6bfa41572f8f03711df49afc306406a33a33dc9cc37d118e1da120e906d214f36"}],"ComponentSizeInKB":19092,"CompsigList":["CP070961.compsig"],"FileList":["/CP070961_BUILD_2.data","/CP070961.vmexe64","/CP070961.vmfile","/CP070961_VMw.zip","/CP070961.xml","/payload.json","/CP070961_VMw.zip/index.xml","/CP070961_VMw.zip/vendor-index.xml","/CP070961_VMw.zip/metadata.zip","/CP070961_VMw.zip/vib20/CP070961/HPE_bootbank_CP070961_HPD3.2-8.0.0.20613240.vib","/CP070961_VMw.zip/metadata.zip/vendor-index.xml","/CP070961_VMw.zip/metadata.zip/vmware.xml","/CP070961_VMw.zip/metadata.zip/vibs/CP070961--8461313719284613183.xml","/CP070961_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070961_HPD3.2-8.0.0.20613240.xml"],"Name":"CP070961.zip","SHA1Sum":"5ea3802c1de14ac33186af4c4d5b3c7c1c12981a","SHA256Sum":"0780c30ae6088fe290d2f25cbe659ac8282391aa4dd65c4c3d7b645bd2568dbf","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP070961","Version":"HPD3.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_99d27394991345fd9a3b2b711d","SupportedDevices":["4d2340a5-304f-3330-3230-304a57444c42","4d2340a5-304f-3130-3630-304a57444c41","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3830-304a57444b56","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3430-304a57444b50"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_M7450ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304b584e5845","Version":"HPK6"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_M7450ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3936-304b584e5a55","Version":"HPK6"},{"DeviceName":"Micron-7450-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450_M7450ALLHPK6.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3053-3130-3932-304b584e5846","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"Micron_7450_M7450ALLHPK6.fwpkg","SHA1Sum":"48e62474c0a88b83452f480b3da1b55025c07154","SHA256Sum":"aa9331908842d084644d563bb3c855d373ff9fbd5ea29eac650902ac2138dbd8","SHA512Sum":"5769e975c119541d90f8919467fb4a147de67bc19250154b5f01ce552344b1b86172a2ec521d00af612fd0ce25a494069176733851b9c7fed358b775553fa205"}],"ComponentSizeInKB":2330,"CompsigList":[],"FileList":["Micron_7450_M7450ALLHPK6.HPb","Micron_7450_M7450ALLHPK6.xml","payload.json"],"Name":"Micron_7450_M7450ALLHPK6.fwpkg","SHA1Sum":"48e62474c0a88b83452f480b3da1b55025c07154","SHA256Sum":"aa9331908842d084644d563bb3c855d373ff9fbd5ea29eac650902ac2138dbd8","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3052-3030-3438-304b584e5845","562340a5-3052-3030-3936-304b584e5a55","562340a5-3053-3130-3932-304b584e5846"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - VR000480KXNXE,VR000960KXNZU and VS001920KXNXF","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VR000480KXNXE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR000960KXNZU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VS001920KXNXF","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9f6c84bee6ee48b58e6726b4f1","SupportedDevices":["562340a5-3052-3030-3438-304b584e5845","562340a5-3052-3030-3936-304b584e5a55","562340a5-3053-3130-3932-304b584e5846"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZ1LB3T8HMLA-00007","FirmwareImages":[{"DelayAfterInstallSec":10,"FileName":"EDB7602Q.bin","InstallDurationSec":"120","Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-144d-a808144da801","Version":"EDB7602Q"}]},"Files":[{"Checksum":[{"Filename":"cp070453.exe","SHA1Sum":"8746188910fb9f6c072e78b968ab90ebb2129a67","SHA256Sum":"6a619af1a8daec6baaa2472933927144869178c307f5ed542d444acad328e1d8","SHA512Sum":"218ef96f026b1b5d9a68f465c9a034d84122567b6168ddf1618ac0eaaef839c388d8553841c75b0e4831303eaf8f787ebf8c987a6bad9ea7adfab53c3d5bc464"}],"ComponentSizeInKB":7022,"CompsigList":["cp070453.compsig"],"FileList":["cp070453.xml","cpqsetup.exe","EDB7602Q.bin","ilorest_chif.dll","payload.json"],"Name":"cp070453.exe","SHA1Sum":"8746188910fb9f6c072e78b968ab90ebb2129a67","SHA256Sum":"6a619af1a8daec6baaa2472933927144869178c307f5ed542d444acad328e1d8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-144d-a808144da801"],"TypeOfChange":"1","Version":"EDB7602Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Microsoft Windows - MZ1LB3T8HMLA-00007 Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MZ1LB3T8HMLA-00007","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aa09ce6818eb43509673c73cdf","SupportedDevices":["4d2340a5-315a-424c-3354-384894df255d"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["11.0","10.0.20317.25398","10.0.17600.18999","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H09","H10","H10","H10","H08","H08"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U40_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020f","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U40_3.70_08_19_2026.fwpkg","SHA1Sum":"c8454e2aa3337466a3b0a7961c51e837f8da18a9","SHA256Sum":"3af9c325e7d38257ba4ca2ac680215b896177d7be852c5e5b2b8aafd7acbf10e","SHA512Sum":"8d344777e9a7a5fa25d932472d3aae155cb9c2a4a33a02cf864994afbf06bced8ebec1967c406e4d6ddc173dd44d4c941709bd42736fb55e45b011b07deb9e6f"}],"ComponentSizeInKB":32824,"CompsigList":[],"FileList":["payload.json","U40_3.70_08_19_2026.signed.flash","U40_3.70_08_19_2026.xml"],"Name":"U40_3.70_08_19_2026.fwpkg","SHA1Sum":"c8454e2aa3337466a3b0a7961c51e837f8da18a9","SHA256Sum":"3af9c325e7d38257ba4ca2ac680215b896177d7be852c5e5b2b8aafd7acbf10e","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020f"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 4510 Gen10/HPE ProLiant XL450 Gen10 (U40) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1e7169efdf0546d6b82bf52e92","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U40","U40"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072271.exe","SHA1Sum":"48a24461ded5dababece1ffc9f64267cc17d2d9e","SHA256Sum":"cadf00739c05a2631025d1b805e88ed7de18e784410a336e53c3bde1a4902f9c","SHA512Sum":"bbc5995e477d8492c2c92e40988f3d888cd1e3dcf950862e8c77e1c0b791de8b4f79458ead5e3726cd1fcef58e58fb78fb1cf723b057ea2333571eb82ba735c7"}],"ComponentSizeInKB":1227,"CompsigList":["cp072271.compsig"],"FileList":["cp072271.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp072271.exe","SHA1Sum":"48a24461ded5dababece1ffc9f64267cc17d2d9e","SHA256Sum":"cadf00739c05a2631025d1b805e88ed7de18e784410a336e53c3bde1a4902f9c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.25.115.0"}],"InstallationDependency":{},"Name":"HPE Intel i40ea Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7c732cd7890c4a8ba6f0ee3a35","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572103C0000","a6b1a447-382a-5a4f-8086-158A15900000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"CP070924.zip","SHA1Sum":"d94a05f402e6b1c0ca0c733da595780dc11a36d4","SHA256Sum":"031ed4a301b48f6df33ccd4fbe2218595e78593b906a8b614131df2b69c33424","SHA512Sum":"75e24bd36826cbf32774385d7656cf1eb3c516ba890b4b74d0b86f44b2713d1a8781b7d1e5cf74b430803927cfc8a4e1a8b938420c552066a966d285e7c21704"}],"ComponentSizeInKB":19940,"CompsigList":["CP070924.compsig"],"FileList":["/CP070924_BUILD_4.data","/CP070924.vmexe64","/CP070924.vmfile","/CP070924_VMw.zip","/CP070924.xml","/payload.json","/CP070924_VMw.zip/index.xml","/CP070924_VMw.zip/vendor-index.xml","/CP070924_VMw.zip/metadata.zip","/CP070924_VMw.zip/vib20/CP070924/HPE_bootbank_CP070924_GPK8.4-8.0.0.20613240.vib","/CP070924_VMw.zip/metadata.zip/vendor-index.xml","/CP070924_VMw.zip/metadata.zip/vmware.xml","/CP070924_VMw.zip/metadata.zip/vibs/CP070924-1277334331218524609.xml","/CP070924_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070924_GPK8.4-8.0.0.20613240.xml"],"Name":"CP070924.zip","SHA1Sum":"d94a05f402e6b1c0ca0c733da595780dc11a36d4","SHA256Sum":"031ed4a301b48f6df33ccd4fbe2218595e78593b906a8b614131df2b69c33424","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8","VibList":[{"Name":"CP070924","Version":"GPK8.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a85bf349ded846479cba888747","SupportedDevices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072280.exe","SHA1Sum":"8bc5f70056ceb9d41242a9bacbc8aa15e1f9c355","SHA256Sum":"61c9d6529631fa10eccc5ff0c058a481c4dac72df8185c0250b2d361f114d02b","SHA512Sum":"73d4d6939ac3e52c7976e11b2a3903bd71b510fc59b5d98e1d6e47869363d9b56f1dbac5de97faf93f072017c346b879b611acda1df9becefbbd4c21b61b0e30"}],"ComponentSizeInKB":1707,"CompsigList":["cp072280.compsig"],"FileList":["cp072280.xml","cpqsetup.exe","cp_data.xml","icea.cat","icea.inf","icea.sys","iceamsg.dll","install.xml","manifest_icea.man","nicdrvr.dll"],"Name":"cp072280.exe","SHA1Sum":"8bc5f70056ceb9d41242a9bacbc8aa15e1f9c355","SHA256Sum":"61c9d6529631fa10eccc5ff0c058a481c4dac72df8185c0250b2d361f114d02b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec340d3099"],"TypeOfChange":"1","Version":"1.21.114.0"}],"InstallationDependency":{},"Name":"Intel icea Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"icea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\icea.inf_amd64_0d313568beecbfb3"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c1ca0e6099a242c18172d0b856","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","U47","A46","U47","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","02020001","03020101","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Files":[{"Checksum":[{"Filename":"CP072199.zip","SHA1Sum":"c57f6a5f27a1bd2094681cf7caa1d963d32012dd","SHA256Sum":"2499dad9aac868cfc1d7a830e7c95cdedbcaf10796ccffdaf1037eadcfae6917","SHA512Sum":"7e3ef9c0dd715eecdf8d915e6b466a080efb21044c38437b6f2576a3b54237bb1a91d815365b537cdd2d057bbd6b64744652519ff76bb265f3976c6d18a0e8d6"}],"ComponentSizeInKB":8151,"CompsigList":["CP072199.compsig"],"FileList":["/CP072199_BUILD_1.data","/CP072199.vmcfg","/CP072199.vmexe64","/CP072199.vmfile","/CP072199_VMw.zip","/CP072199.xml","/payload.json","/CP072199_VMw.zip/index.xml","/CP072199_VMw.zip/vendor-index.xml","/CP072199_VMw.zip/metadata.zip","/CP072199_VMw.zip/vib20/CP072199/HPE_bootbank_CP072199_5.04.1-8.0.0.20613240.vib","/CP072199_VMw.zip/metadata.zip/vendor-index.xml","/CP072199_VMw.zip/metadata.zip/vmware.xml","/CP072199_VMw.zip/metadata.zip/vibs/CP072199-8439978499155422694.xml","/CP072199_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072199_5.04.1-8.0.0.20613240.xml"],"Name":"CP072199.zip","SHA1Sum":"c57f6a5f27a1bd2094681cf7caa1d963d32012dd","SHA256Sum":"2499dad9aac868cfc1d7a830e7c95cdedbcaf10796ccffdaf1037eadcfae6917","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04","VibList":[{"Name":"CP072199","Version":"5.04.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_58fe379fbd0f4e37a3ac67cb3e","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60","U46"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4T adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4T_O_SEC_5p0_PLDMoMCTP_80021BD2.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-15938086000e","Version":"5.00"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXV4T_O_SEC_5p0_PLDMoMCTP_80021BD2.fwpkg","SHA1Sum":"e3a306466afaf47ba5742a8f6b9d941ff49451ed","SHA256Sum":"10f5bba78aa090161e67c5e337f39eb17d4d4f950b5e1f75499e09a3505ac4b1","SHA512Sum":"01627668b44d05937468194f10fa8e647d059dddb4d409a650689f512902c038619cd2376e3691229eb8486605ecdff97a70b581c39e15214b991aa301c9fc41"}],"ComponentSizeInKB":10278,"CompsigList":[],"FileList":["HPE_E810_XXV4T_O_SEC_5p0_PLDMoMCTP_80021BD2.HPb","HPE_E810_XXV4T_O_SEC_5p0_PLDMoMCTP_80021BD2.xml","payload.json"],"Name":"HPE_E810_XXV4T_O_SEC_5p0_PLDMoMCTP_80021BD2.fwpkg","SHA1Sum":"e3a306466afaf47ba5742a8f6b9d941ff49451ed","SHA256Sum":"10f5bba78aa090161e67c5e337f39eb17d4d4f950b5e1f75499e09a3505ac4b1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000e"],"TypeOfChange":"1","Version":"5.00"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4T_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_953b84dae8ae42ceb8874bcd9e","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","8.0","9.0","15.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u7.x86_64.rpm","SHA1Sum":"4d7cf2775b0a2bd4bacf111f7ffa18cedb145ee8","SHA256Sum":"955989f6aa1831ff275ff4f05236c2ab54e9d52b3c7415b4b07660c43b73c37b","SHA512Sum":"cf6222fe2ea3ac970ebba57d1e2d4068a7b311462a1688d9c961b62dc1a8bd431a9bf0160a631c598d6d274d77bfb772829233ef06c44b8927700b0369177fef"}],"ComponentSizeInKB":5309,"CompsigList":["kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-qla2xxx","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"Name":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u7.x86_64.rpm","SHA1Sum":"4d7cf2775b0a2bd4bacf111f7ffa18cedb145ee8","SHA256Sum":"955989f6aa1831ff275ff4f05236c2ab54e9d52b3c7415b4b07660c43b73c37b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 9 update 7 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_22bda95782ad41e5a1e212825e","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071895.zip","SHA1Sum":"9e6dc9e9d3d95b884f2477d1736df0d5b8006139","SHA256Sum":"e2e26305d2a6f5bb42883645e79aaa08d49dd3420588b76feff98b54347529fa","SHA512Sum":"d55515cf8a5612eb0ac78fc187de2887668e82ac23e60736f485b0f24226aa0c2040427a3300ffce85580506f0d7c6a06956aeec6432a4b7d9530766ae3ed0f4"}],"ComponentSizeInKB":411,"CompsigList":["cp071895.compsig"],"FileList":["/cp071895.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip","/MIS_bootbank_smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.vib","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/index.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/vib20/smartpqi/MIS_bootbank_smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.vib","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/smartpqi-2527423866099698718.xml","/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Microchip-smartpqi_80.4902.0.103-1OEM.800.1.0.20613240.xml"],"Name":"cp071895.zip","SHA1Sum":"9e6dc9e9d3d95b884f2477d1736df0d5b8006139","SHA256Sum":"e2e26305d2a6f5bb42883645e79aaa08d49dd3420588b76feff98b54347529fa","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c","20a6e8e4-bf33-4c71-a6bf-d9ec72979cda"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"smartpqi","Version":"80.4902.0.103-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 8.0 (Driver Component).","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"Microchip-smartpqi:80.4902.0.103-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"smartpqi:80.4902.0.103-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_728c9f02e41c4eda8aa424c034","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","A42","U32","U46","A43","A43","A43","A41","U31","U31","U36","U41","U33","A47","A48","U40","U39","U47","U37","A46","U47","U38","U38","U48","O43","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U50","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U61","U60","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","A66","U71","A66","U68","U72","U68","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071896.zip","SHA1Sum":"68dc76f3797564e3de6210555a477cb00d7ad695","SHA256Sum":"fbbe5e7c4e209d184c71df30d576dc30d6a4bc43580e43bbcb9c5595f725a1cc","SHA512Sum":"a2d9f32ba7bacaf7755768b94e189e66b6c200ed62465d4a47e5c35fde871585b60fdd34e5d8077e5341bf63f2a83b07a2c3f172fad9d6acebe5352607bbbb5e"}],"ComponentSizeInKB":343,"CompsigList":["cp071896.compsig"],"FileList":["/cp071896.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip","/MIS_bootbank_smartpqi_90.4902.0.103-1OEM.900.0.24755229.vib","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/index.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/vendor-index.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/vib20/smartpqi/MIS_bootbank_smartpqi_90.4902.0.103-1OEM.900.0.24755229.vib","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip/vibs/smartpqi--6695129977023339273.xml","/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Microchip-smartpqi_90.4902.0.103-1OEM.900.0.24755229.xml"],"Name":"cp071896.zip","SHA1Sum":"68dc76f3797564e3de6210555a477cb00d7ad695","SHA256Sum":"fbbe5e7c4e209d184c71df30d576dc30d6a4bc43580e43bbcb9c5595f725a1cc","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec12e3fc5c","20a6e8e4-bf33-4c71-a6bf-d9ec72979cda"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"smartpqi","Version":"90.4902.0.103-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10 Smart Array and Gen10 Plus and Gen11 Smart RAID Controller Driver for VMware vSphere 9.0 (Driver Component).","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"Microchip-smartpqi:90.4902.0.103-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"smartpqi:90.4902.0.103-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_198e59df9cd946a39158461466","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","A42","U32","U46","A43","A43","A43","A41","U31","U31","U36","U41","U33","A47","A48","U40","U39","U47","U37","A46","U47","U38","U38","U48","O43","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U50","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U61","U60","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","A66","U71","A66","U68","U72","U68","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"igb-kmp-default-5.20.28_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"f48efffe9938a223f6f586c1331ad896883cc13b","SHA256Sum":"17ca06f055ec6512fc36ad2f48923538e1420d6bf9993d7243a9de4981034b04","SHA512Sum":"d305c4edb0314bdb9cb208c1df4d04486bd3aee810a1e2dc36d9988dcea5d20919b2b61a2fce442773a0d1a673fb7a52afa247f90a57ddc6779c15d9d1d612f5"}],"ComponentSizeInKB":217,"CompsigList":["igb-kmp-default-5.20.28_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/igb.ko","./usr/share/doc/packages/igb-kmp-default","./usr/share/doc/packages/igb-kmp-default/COPYING","./usr/share/doc/packages/igb-kmp-default/README","./usr/share/man/man7/igb.7.gz","./usr/share/pci.ids.d/pci.ids.igb-kmp-5.20.28","./usr/share/smartupdate/igb-kmp-default/component.xml"],"Name":"igb-kmp-default-5.20.28_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"f48efffe9938a223f6f586c1331ad896883cc13b","SHA256Sum":"17ca06f055ec6512fc36ad2f48923538e1420d6bf9993d7243a9de4981034b04","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1df98b3d"],"TypeOfChange":"1","Version":"5.20.28-1"}],"InstallationDependency":{},"Name":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"igb-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b0d045ca58a4440dbd32f71051","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H10","H10","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.70 (08/20/2026)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.70 (08/20/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u64-2.70_2026_08_20-1.1.x86_64.rpm","SHA1Sum":"fc5922d30b53e596260a9d6edaa1adb5bf4e6e82","SHA256Sum":"a9e572c9834d74158c85ae4a0da1ad57bf888218ecbd82bda7bd622807b6c148","SHA512Sum":"255558e17f3b221154127f1e748d9c4c65cfc9a571c0d0118b7bf367312acaa199158583d68d6725a5619fa68f03d21949e1fe437ca71c5fc6be4a650db48078"}],"ComponentSizeInKB":16735,"CompsigList":["firmware-system-u64-2.70_2026_08_20-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.70_2026_08_20-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.70_2026_08_20-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.70_2026_08_20-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.70_2026_08_20-1.1/CP073277.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.70_2026_08_20-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.70_2026_08_20-1.1/U64_2.70_08_20_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.70_2026_08_20-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.70_2026_08_20-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u64-2.70_2026_08_20-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073277.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073277.scexe"],"Name":"firmware-system-u64-2.70_2026_08_20-1.1.x86_64.rpm","SHA1Sum":"fc5922d30b53e596260a9d6edaa1adb5bf4e6e82","SHA256Sum":"a9e572c9834d74158c85ae4a0da1ad57bf888218ecbd82bda7bd622807b6c148","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.70_08-20-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d86ad8d823164ff38fab0372ac","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U64"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_FVL4HP.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.4008.0"}]},"Files":[{"Checksum":[{"Filename":"cp072305.exe","SHA1Sum":"9b0cbe93b1c706b411b0d67968c6f216b31e448e","SHA256Sum":"17a18c9dfb4531c8a911be53b9dff1aa14208fb99ef9fa578e7422ea73dcc346","SHA512Sum":"6d370dafc5fa0e9c8d111c79980015b28911c06bbcdfc47fbc3a2ac258339d2a04c727199d462c9681b6b92f316d0e88da3667f36875619b71ce7ed758cbf7bf"}],"ComponentSizeInKB":12436,"CompsigList":["cp072305.compsig"],"FileList":["cp072305.xml","cpqsetup.exe","FW/","FW/BootIMG.FLB","FW/BootIMG_FVL4HP.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP.txt","FW/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.txt","FW/HPE_361T.txt","FW/HPE_361T_H65030-003_2.25_80001147.txt","FW/HPE_366FLR_G41713-00x_800011A1.txt","FW/HPE_366T_MAP.txt","FW/HPE_366T_Quad_H73104-00x_800011F1.txt","FW/HPE_369i_88E1512_P01_88E1512_P23_NCSI_6p00_80003AC3.bin","FW/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","FW/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","FW/HPE_40G_Adapter_VPD_MAP.txt","FW/HPE_562FLR-SFP_DP_H47655-000_11p1p7_9p50_8000F231.bin","FW/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","FW/HPE_562SFP_DP_H44490-000_11p1p7_9p50_8000F232.bin","FW/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","FW/HPE_563i_KR_DP_800035C0.bin","FW/HPE_568i_Backplane_2x10G_P01_NCSI_6p00_80003AC4.bin","FW/HPE_Apollo_PHY_Auto_Detect_NCSI_6p00_80003AC2.bin","FW/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_6p00_80003AC5.bin","FW/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","FW/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","FW/HPE_XG_SGVL_Adapter_VPD_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp072305.exe","SHA1Sum":"9b0cbe93b1c706b411b0d67968c6f216b31e448e","SHA256Sum":"17a18c9dfb4531c8a911be53b9dff1aa14208fb99ef9fa578e7422ea73dcc346","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"5.4.9.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","SWKey":"e1r63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","SWKey":"e1r64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","SWKey":"e1r65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","SWKey":"ixn63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","SWKey":"ixt63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","SWKey":"ixt64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","SWKey":"ixn64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","SWKey":"ixt65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","SWKey":"ixn65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","SWKey":"i40ea63.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","SWKey":"i40ea64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","SWKey":"i40ea65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","SWKey":"ixs64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","SWKey":"ixs65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","SWKey":"i40eb65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","SWKey":"i40eb64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","SWKey":"e1r68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","SWKey":"i40ea68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","SWKey":"i40eb68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","SWKey":"ixn68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","SWKey":"ixs68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","SWKey":"ixt68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.1.197.0"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","SWKey":"icea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","SWKey":"iavf.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","SWKey":"ixs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","SWKey":"vxs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Intel Online Firmware Upgrade Utility for Windows Server x64 Editions for HPE ProLiant Gen9 and Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"HPNVMUpdate.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6c31fa6811a24d1da9a65e7fae","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-1521103c337f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","U36","U39","U45","O43","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000222","Version":"v3.76 (05/28/2026)"},{"DeviceName":"System BIOS - U48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U48_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000224","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp072034.exe","SHA1Sum":"3c3ae80a9d81fc7b890d91de0a92949f1f1535f3","SHA256Sum":"58865c692bf960fcf3627a635cf2c9d4fec6a30ddf6fb7fe6b40d8f896c365db","SHA512Sum":"400667c419d51f821b47450c8966e1695b4c479987e997d53f59d789ae41ef79d04b8c837db9352c249a9663bc3b0926a949bff572a6fff8190b1dcbb8a1e4f6"}],"ComponentSizeInKB":8767,"CompsigList":["cp072034.compsig"],"FileList":["cp072034.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U48_3.76_05_28_2026.signed.flash"],"Name":"cp072034.exe","SHA1Sum":"3c3ae80a9d81fc7b890d91de0a92949f1f1535f3","SHA256Sum":"58865c692bf960fcf3627a635cf2c9d4fec6a30ddf6fb7fe6b40d8f896c365db","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000222","00000000-0000-0000-0000-000000000224"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus (U48) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e5f6d5aeca9a40f384e5f97d0e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U48"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072957.exe","SHA1Sum":"1f6b57a277380ee8d8336a81c6c683dcee599b9e","SHA256Sum":"a65cb641a1d53b9d70ae6266f34b3e3db92c5da7b6bef78caa0acec3d9feeae9","SHA512Sum":"8b611396f9c00d6c909d387254807b26335cc4fcedae00cfcee01563704f5ecb652a65619ed151807cb80c49416494ae5c8a5feda6a92a0f4083db2c1a845977"}],"ComponentSizeInKB":19288,"CompsigList":["cp072957.compsig"],"FileList":["ams.cab","ams.msi","cp072957.xml","cpqsetup.exe","install.xml","multisetup.dll","SmaInstall.cab","VC_redist.x64.exe"],"Name":"cp072957.exe","SHA1Sum":"1f6b57a277380ee8d8336a81c6c683dcee599b9e","SHA256Sum":"a65cb641a1d53b9d70ae6266f34b3e3db92c5da7b6bef78caa0acec3d9feeae9","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8b303467"],"TypeOfChange":"1","Version":"2.90.0.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Agentless Management Service for Microsoft Windows x64","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"ams.exe","SWKeyExpectedPath":"%ProgramFiles%\\OEM\\AMS\\service"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b7d18c7fd7c44f0b925857a166","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-33061590027f","a6b1a447-382a-5a4f-103c-33071590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","A40","U30","U32","U41","U33","U40","U37","U38","U38","A41","U43","U44","A42","A43","U48","U31","U31","U39","U45","I43","I42","H09","U39","A42","A43","A43","A42","I44","U46","U46","U47","U47","U50","A47","A48","A46","U61","U60","U56","H08","H08","H10","U64","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWKGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVLACBA0HPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a574b4755","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-2c27a7a9a4-HPD4-2.1.x86_64.rpm","SHA1Sum":"931c812907f63a6ced12be8707e3e37ed0345aa0","SHA256Sum":"56339f96eebdde555e0f79e342c75681ed812bbe4cb4352a189a92e071e4cc26","SHA512Sum":"b537e7644b1282178efc921d040b20178ef46e72fe6ba4dd8f2e6bc0a455c6a83fbd11d6224feef190425d1f561b34b12cbe0f6a2adddd7480726482ba25286d"}],"ComponentSizeInKB":6277,"CompsigList":["firmware-hdd-2c27a7a9a4-HPD4-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/CP073158.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/WVLACBA0HPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-2c27a7a9a4-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073158.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073158.scexe"],"Name":"firmware-hdd-2c27a7a9a4-HPD4-2.1.x86_64.rpm","SHA1Sum":"931c812907f63a6ced12be8707e3e37ed0345aa0","SHA256Sum":"56339f96eebdde555e0f79e342c75681ed812bbe4cb4352a189a92e071e4cc26","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a574b4755"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWKGU Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWKGU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_89a8c56e31f74798987f0f335a","SupportedDevices":["4d2340a5-3042-3430-3030-304a574b4755"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072096.exe","SHA1Sum":"d38162a403a460f9595044cae05cdd40d504f9c6","SHA256Sum":"ec5de94ef691ea6e804ada02d701dfbd265cca5a29573706e4a7ac19d3c06fa5","SHA512Sum":"7d5cd8b31a6b43c2ef31a82b9ae3829475fd3d16169cb9e4d44eba1f11556204cb43605317d248ffbf30d8cbd59a231969d28fb4538fcff0ca9f1ff7b830c47a"}],"ComponentSizeInKB":8983,"CompsigList":["cp072096.compsig"],"FileList":["cp072096.xml","cpqsetup.exe","cp_data.xml","genericmsi.dll","SSACLI66590_X64.msi"],"Name":"cp072096.exe","SHA1Sum":"d38162a403a460f9595044cae05cdd40d504f9c6","SHA256Sum":"ec5de94ef691ea6e804ada02d701dfbd265cca5a29573706e4a7ac19d3c06fa5","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9f015b42"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI for Windows 64-bit for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"ssacli.exe","SWKeyExpectedPath":"%ProgramFiles%\\Smart Storage Administrator\\ssacli\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9d9360f5551246ff8132f5231c","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A42","A47","A48","U50","U47","A46","U47","U50","A43","A43","A43","HPE Apollo 6500 Gen10 Plus (Chassis)","U48","O43","I44","I45","U63","U58","U59","U54","U54","U54","U63","U58","U58","A56","A56","A55","A55","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U57","U65","U65","U62","U68","U71","U71","U68","U72","A66","A66","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_NS204i_1.2.14.1034","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1034_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1034"},{"DeviceName":"HPE_NS204i_1.2.14.1034","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1034_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1034"},{"DeviceName":"HPE_NS204i_1.2.14.1034","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1034_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1034"},{"DeviceName":"HPE_NS204i_1.2.14.1034","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1034_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1034"},{"DeviceName":"HPE_NS204i_1.2.14.1034","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1034_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900455","Version":"1.2.14.1034"},{"DeviceName":"HPE_NS204i_1.2.14.1034","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1034_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030f","Version":"1.2.14.1034"},{"DeviceName":"HPE_NS204i_1.2.14.1034","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1034_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900310","Version":"1.2.14.1034"},{"DeviceName":"HPE_NS204i_1.2.14.1034","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_NS204i_1.2.14.1034_A.HPb","InstallDurationSec":600,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159004c4","Version":"1.2.14.1034"}]},"Files":[{"Checksum":[{"Filename":"HPE_NS204i_1.2.14.1034_A.fwpkg","SHA1Sum":"72ca69fa663d65823a82f328e55a402918b4a504","SHA256Sum":"7bbc89fec09f8a461881f1dcf03075bb28243b54d2150cc3d4ee0df04551647c","SHA512Sum":"0d1d275d1eacc0876eb53d4aab15dff821e365a6c61b5524b2fd9a8e4902fe5e7e6a168e06637e7e8ccdc6bdc28185a1537fc1ff98f378ab1ad1001584401f3a"}],"ComponentSizeInKB":7219,"CompsigList":[],"FileList":["HPE_NS204i_1.2.14.1034_A.HPb","HPE_NS204i_1.2.14.1034_A.xml","payload.json"],"Name":"HPE_NS204i_1.2.14.1034_A.fwpkg","SHA1Sum":"72ca69fa663d65823a82f328e55a402918b4a504","SHA256Sum":"7bbc89fec09f8a461881f1dcf03075bb28243b54d2150cc3d4ee0df04551647c","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900455","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-224115900310","a6b1a447-382a-5a4f-1b4b-2241159004c4"],"TypeOfChange":"1","Version":"1.2.14.1034"}],"InstallationDependency":{},"MinimumActiveVersion":"1.2.14.1018","Name":"Firmware Package - HPE NS204mff Boot Controller, HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"03791590","SWKeyExpectedPath":"firmware"},{"Name":"03801590","SWKeyExpectedPath":"firmware"},{"Name":"02F61590","SWKeyExpectedPath":"firmware"},{"Name":"030E1590","SWKeyExpectedPath":"firmware"},{"Name":"04551590","SWKeyExpectedPath":"firmware"},{"Name":"030F1590","SWKeyExpectedPath":"firmware"},{"Name":"03101590","SWKeyExpectedPath":"firmware"},{"Name":"04C41590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4a4df0491dad41fc9dfff517e3","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900455","a6b1a447-382a-5a4f-1b4b-224115900310","a6b1a447-382a-5a4f-1b4b-22411590030f","a6b1a447-382a-5a4f-1b4b-2241159004c4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0","22.04"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","I45","U58","U58","U54","U58","U54","U54","U63","U59","U63","U34","U34","A42","U46","U30","A42","U46","U32","A43","A43","A43","U41","U33","A47","A48","U47","A46","U47","U48","U40","U50","U39","I44","A42","H10","U61","U60","H10","H10","U46","U65","U65","U69","U69","I46","H11","U72","U68","U68","U68","U70","HPE Cray XD665","U68","A66","A66","U72","A59","A72"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"b34e5677-21dc-45d3-872b-42f76fee9053","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp073085.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-86800a000101","Version":"04.01.05.312"}]},"Files":[{"Checksum":[{"Filename":"cp073089.exe","SHA1Sum":"6ca0a9d781230a0baed7b51ef2ad7b21c540c703","SHA256Sum":"d9442868c0848b176d3df159f88d020525874b113a289c5d1378bdbc8fe7d7a1","SHA512Sum":"2be0497649dac36f301eb1c3afc4ac913b07a5964aea4ec798cc6be74c859f7570e03739bfc314d732672d4e11c4e5c0ac48661029bb0fc4636f06137006d319"}],"ComponentSizeInKB":3705,"CompsigList":["cp073089.compsig"],"FileList":["cp073085.compsig","cp073085.zip","cp073089.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp073089.exe","SHA1Sum":"6ca0a9d781230a0baed7b51ef2ad7b21c540c703","SHA256Sum":"d9442868c0848b176d3df159f88d020525874b113a289c5d1378bdbc8fe7d7a1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-86800a000101"],"TypeOfChange":"1","Version":"04.01.05.312"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","DeviceGUID":"C734E171-8721-48C9-9ED6-D5BC7DA5EF8D","Message":"HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers version 0.1.4.0 or newer","OSVersion":{},"RequirementGUID":"A6B1A447-382A-5A4F-3C10-3C100A000303","SWKey":"IE-Gen10","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"0.1.4.0"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE Gen10 Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e86faaa9ceec4a21983724bed3","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U41","U33","U40","U39","U45","U37","U38","U38","U39","H08","H08","I43","I42"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-igb-kmp-default-6.20.28_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"a128ee4709684c6520ee4a21e0202a04524f61de","SHA256Sum":"c5861bfb7abd28e2ba3fa492b2b54eb8cbd2447213cc47d1e7be24f0a9483ede","SHA512Sum":"432f1f7e87f22e36d1370dce8188abec6e288fffe7d1f18fdb041e06115e069a75d746e2a5e4e4a1829e13f51c61145f780fc0e4cadf9580500b63a313ec743e"}],"ComponentSizeInKB":175,"CompsigList":["hp-igb-kmp-default-6.20.28_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-igb","./lib/modules/6.4.0-150700.51-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"Name":"hp-igb-kmp-default-6.20.28_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"a128ee4709684c6520ee4a21e0202a04524f61de","SHA256Sum":"c5861bfb7abd28e2ba3fa492b2b54eb8cbd2447213cc47d1e7be24f0a9483ede","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"TypeOfChange":"1","Version":"6.20.28-1"},{"Checksum":[{"Filename":"hp-igb-kmp-default-6.20.28_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"f731340b141e676ad34115a79f15e4b8dcca6de0","SHA256Sum":"e5bd41e77fdca0d4793232e9d26fb05709f380017a36c8a8c25d06294bdf4b15","SHA512Sum":"df691d9b5abb420d8e1c9a27fb21dca6c52b5dbe4aae5bd7c015090e223afa7431e95005f6e2e4346eed653284fdc92d006909e83a369b37a8daa0c9fbbfa8d3"}],"ComponentSizeInKB":4164,"CompsigList":["hp-igb-kmp-default-6.20.28_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-igb.conf","./etc/dracut.conf.d/hp-igb-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-igb","./lib/modules/6.4.0-150600.21-default/updates/hp-igb/igb.ko","./usr/share/smartupdate/hp-igb-kmp-default/component.xml"],"Name":"hp-igb-kmp-default-6.20.28_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"f731340b141e676ad34115a79f15e4b8dcca6de0","SHA256Sum":"e5bd41e77fdca0d4793232e9d26fb05709f380017a36c8a8c25d06294bdf4b15","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646"],"TypeOfChange":"1","Version":"6.20.28-1"}],"InstallationDependency":{},"Name":"HPE Intel igb Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-igb-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c68d67c0519d4d5e9c0d5084fa","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H10","H10","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","U77","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JXUCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2BP.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a58554343","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070962.zip","SHA1Sum":"4a3c6e9eb8a0ff119b2d8f4e9c1c4947ca345253","SHA256Sum":"cd7eaa974a2310a2e0e686af5982358ebf1c2b5f270f7c864122425804fb5865","SHA512Sum":"bfe69fd88db28aaf198f4a3c31150cf65fac20a2738bdc31ad29ce418fd68159d4118eb1da8893ddf0d83a02084b43e5d17d8ddf508e91366214510e082634ba"}],"ComponentSizeInKB":21736,"CompsigList":["CP070962.compsig"],"FileList":["/CP070962_BUILD_1.data","/CP070962.vmexe64","/CP070962.vmfile","/CP070962_VMw.zip","/CP070962.xml","/payload.json","/CP070962_VMw.zip/index.xml","/CP070962_VMw.zip/vendor-index.xml","/CP070962_VMw.zip/metadata.zip","/CP070962_VMw.zip/vib20/CP070962/HPE_bootbank_CP070962_HPD4.1-8.0.0.20613240.vib","/CP070962_VMw.zip/metadata.zip/vendor-index.xml","/CP070962_VMw.zip/metadata.zip/vmware.xml","/CP070962_VMw.zip/metadata.zip/vibs/CP070962-7134521735386207040.xml","/CP070962_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070962_HPD4.1-8.0.0.20613240.xml"],"Name":"CP070962.zip","SHA1Sum":"4a3c6e9eb8a0ff119b2d8f4e9c1c4947ca345253","SHA256Sum":"cd7eaa974a2310a2e0e686af5982358ebf1c2b5f270f7c864122425804fb5865","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a58554343"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070962","Version":"HPD4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000JXUCC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JXUCC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_218411b58a6c4fb0a9950324bd","SupportedDevices":["4d2340a5-3042-3431-3030-304a58554343"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Power Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Files":[{"Checksum":[{"Filename":"cp069607.exe","SHA1Sum":"f37922cfcb32c0ab27f57886127205222c0118b9","SHA256Sum":"eff91846781264d2ec7fddd521ac097395e732e87ae7113e1d5315febbb1c1b7","SHA512Sum":"3c706aa8b6ef48090abf1e9f175bd140b417ab502d1f9efb6e45493bbfa7eef99f021d8d6e232127d00862fd00ce940d4a5613809e9e8df4904692c536eb1601"}],"ComponentSizeInKB":667,"CompsigList":["cp069607.compsig"],"FileList":["cp069607.xml","cpqsetup.exe","LICENSE.txt","payload.json","PICGen10_v1.1.4_hdr.signed.hex","SecureFlash64.dll"],"Name":"cp069607.exe","SHA1Sum":"f37922cfcb32c0ab27f57886127205222c0118b9","SHA256Sum":"eff91846781264d2ec7fddd521ac097395e732e87ae7113e1d5315febbb1c1b7","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash for Windows x64 - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7bdaa82f3b0243c79e8496b113","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["A43","A42","A43","A42","A43","A42","A41","A40","U34","U34","U46","U30","U46","U32","U31","U60","U43","U32","U41","U33","U61","U44","U50","U39","U50","U39","U56"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072281.exe","SHA1Sum":"9c1d0cc2fbd4e6fd8a460c0251d3df10a7856f3f","SHA256Sum":"093fa9445baaf229971b67676225dcf98d996d938ae1d9730e774de51bdde3bf","SHA512Sum":"739e5a246806faf2ac7dea7f934a3e36809764265ca00d5ea7ded778b047e89baa9b953807a2c25d45e1b79ea03f82b108f3649f1b2a29407f939ac255efab4f"}],"ComponentSizeInKB":1230,"CompsigList":["cp072281.compsig"],"FileList":["cp072281.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp072281.exe","SHA1Sum":"9c1d0cc2fbd4e6fd8a460c0251d3df10a7856f3f","SHA256Sum":"093fa9445baaf229971b67676225dcf98d996d938ae1d9730e774de51bdde3bf","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"TypeOfChange":"1","Version":"1.25.113.0"}],"InstallationDependency":{},"Name":"Intel i40ea Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40ea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_63875bd3279548b08338d2615d","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-157280860000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","H08","H08","H10","H10","H10","A42","U46","U46","A43","A43","A47","A48","U47","A46","U47","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U47","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000240GWKVK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3234-3047574b564b","Version":"HPG5"},{"DeviceName":"MK000480GWJPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-3047574a504e","Version":"HPG5"},{"DeviceName":"MK000960GWJPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-3047574a5050","Version":"HPG5"},{"DeviceName":"MK001920GWJPQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-3047574a5051","Version":"HPG5"},{"DeviceName":"VK000240GWJPD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-3047574a5044","Version":"HPG5"},{"DeviceName":"VK000480GWJPE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-3047574a5045","Version":"HPG5"},{"DeviceName":"VK000960GWJPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-3047574a5046","Version":"HPG5"},{"DeviceName":"VK001920GWJPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-3047574a5048","Version":"HPG5"},{"DeviceName":"VK003840GWJPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4IYVHPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-3047574a504b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-aef2a690c9_0HPG5-2.1_amd64.deb","SHA1Sum":"8af87e104b47843e11399b876e4dee746e29bb73","SHA256Sum":"eb899e2c76f4eac16aafb6f76e66fc4fb35ba5879491ab29984303b20e9c69a6","SHA512Sum":"f3276f165e176b5e56ae162154c747e4cd47160d72d797ba1f4b542d24b10a381e4e92b124911fc925347704c3b4f7cc7f190f1a70b9fe716efeddb0b010324d"}],"ComponentSizeInKB":3020,"CompsigList":["firmware-hdd-aef2a690c9_0HPG5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/4IYVHPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/CP071740.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071740.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-aef2a690c9-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071740.scexe"],"Name":"firmware-hdd-aef2a690c9_0HPG5-2.1_amd64.deb","SHA1Sum":"8af87e104b47843e11399b876e4dee746e29bb73","SHA256Sum":"eb899e2c76f4eac16aafb6f76e66fc4fb35ba5879491ab29984303b20e9c69a6","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3234-3047574b564b","4d2340a5-304b-3030-3438-3047574a504e","4d2340a5-304b-3030-3936-3047574a5050","4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3030-3438-3047574a5045","562340a5-304b-3030-3936-3047574a5046","562340a5-304b-3130-3932-3047574a5048","562340a5-304b-3330-3834-3047574a504b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000240GWJPD, VK000480GWJPE, VK000960GWJPF, VK001920GWJPH, VK003840GWJPK, MK000240GWKVK, MK000480GWJPN, MK000960GWJPP and MK001920GWJPQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"MK000240GWKVK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWJPN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWJPP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWJPQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000240GWJPD","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GWJPE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWJPF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWJPH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWJPK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_236dc077387a4562b1c1d010c8","SupportedDevices":["4d2340a5-304b-3130-3932-3047574a5051","562340a5-304b-3130-3932-3047574a5048","4d2340a5-304b-3030-3234-3047574b564b","562340a5-304b-3030-3234-3047574a5044","562340a5-304b-3330-3834-3047574a504b","4d2340a5-304b-3030-3438-3047574a504e","562340a5-304b-3030-3438-3047574a5045","4d2340a5-304b-3030-3936-3047574a5050","562340a5-304b-3030-3936-3047574a5046"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp068639.exe","SHA1Sum":"886df1f2d9de7e06392c89fd6a95399413544354","SHA256Sum":"3963f7e2f3c2ea44dce9e2071c5d6d057a92bfc7e222bdf0bc4e61a3e5ddfdb4","SHA512Sum":"e9779bcd90c05727eacb2141c0407757e0622c5cddc8f6cde98c1b2b21c9a33120e64dc59a523cc52050e707aa2f2fd601fc967896a6b758efdd6e44dee7e360"}],"ComponentSizeInKB":3363,"CompsigList":["cp068639.compsig"],"FileList":["cp068639.xml","cpqsetup.exe","GPM1643ASAD5.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068639.exe","SHA1Sum":"886df1f2d9de7e06392c89fd6a95399413544354","SHA256Sum":"3963f7e2f3c2ea44dce9e2071c5d6d057a92bfc7e222bdf0bc4e61a3e5ddfdb4","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_23d8ca08b6234a54bf8d875213","SupportedDevices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d550523365-HPD3-6.1.x86_64.rpm","SHA1Sum":"0cdddbd0447af5b7367cbfc8e447e4a7c096767a","SHA256Sum":"9015b33f9db4806ea4ad0ad594d36aaf326891015f73f23a8668d2d4d4b1d19b","SHA512Sum":"6689a5b9126da7bd87b4087b6b3e472c0f93074d1c6fca45dd766f463b279420bd0132c3fab77f6d4167d4444231a62bd598c27b601a4da3a5329d912c7f5f7e"}],"ComponentSizeInKB":7037,"CompsigList":["firmware-hdd-d550523365-HPD3-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/CP068850.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/PCHFA2B3.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d550523365-HPD3-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068850.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068850.scexe"],"Name":"firmware-hdd-d550523365-HPD3-6.1.x86_64.rpm","SHA1Sum":"0cdddbd0447af5b7367cbfc8e447e4a7c096767a","SHA256Sum":"9015b33f9db4806ea4ad0ad594d36aaf326891015f73f23a8668d2d4d4b1d19b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB016000JXLBA and MB018000JXLAU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cd1b23f75c144dcbb22cd0a6a6","SupportedDevices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWUDB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57554442","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068748.exe","SHA1Sum":"e23e814d9ce520c4e56d5ce5053f8652b366094e","SHA256Sum":"f3ece865a1af1c77d8571eaf8629954effa0bed8fcc26463849a85e4cba56f7d","SHA512Sum":"e1c74508e3f2a38b8c3ac32791259d31ec6d0cca411badd67243a38cab35e60fa468d1c05488a5104601cd35605fa946ffac2c333d334c8ea18fcf8dc5d16c30"}],"ComponentSizeInKB":4526,"CompsigList":["cp068748.compsig"],"FileList":["cp068748.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WLEBsssASFD4.rel"],"Name":"cp068748.exe","SHA1Sum":"e23e814d9ce520c4e56d5ce5053f8652b366094e","SHA256Sum":"f3ece865a1af1c77d8571eaf8629954effa0bed8fcc26463849a85e4cba56f7d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57554442"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB014000JWUDB Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWUDB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e33b47e3812f43beab0d6c1014","SupportedDevices":["4d2340a5-3042-3431-3030-304a57554442"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070511.zip","SHA1Sum":"4061b9f9f6c304ed2b8e7a22e31ac12f2534bdc2","SHA256Sum":"3f5bbbd969e34c7b8d95a0a4fc759beb344921cdc9559f95c42214fae5ae08ae","SHA512Sum":"aa059e21be4d3fdeaea9ddea95fe42d55999fbe7e537aff4f913b5d0b2daf90b9ca85a0f2553a7cfc0f1889e4faa016583f73836761283707dd6e2cf030ade3f"}],"ComponentSizeInKB":702,"CompsigList":["cp070511.compsig"],"FileList":["/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip","/cp070511.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/index.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/vendor-index.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.5.86.0-1OEM.900.0.24755229.vib","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/qlnativefc--6136840453486731005.xml","/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.5.86.0-1OEM.900.0.24755229.xml"],"Name":"cp070511.zip","SHA1Sum":"4061b9f9f6c304ed2b8e7a22e31ac12f2534bdc2","SHA256Sum":"3f5bbbd969e34c7b8d95a0a4fc759beb344921cdc9559f95c42214fae5ae08ae","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2026.04.01","VibList":[{"Name":"qlnativefc","Version":"5.5.86.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE QLogic Fibre Channel driver component for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":380,"RebootRequired":"yes","SWKeys":[{"Name":"qlnativefc:5.5.86.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.5.86.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3c77b3aa54094ea49e74eddd39","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000GWUDA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLEBsssATFG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304757554441","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070965.zip","SHA1Sum":"fb35fca5349fa508fba7abf4d29fe8c9a9275b28","SHA256Sum":"cf9e99f5f3d5e36f16636374f4f88e0212fa306b7cfba5057585c5b8470a6141","SHA512Sum":"d0a324230014c4f451c161b259a50fef38e95bff67c7277e0e28ed083c7df1913559d5f401cfb5be60d2cd349f9e50187bf6962a0d7dfa1a3c12531a00ce05f8"}],"ComponentSizeInKB":20416,"CompsigList":["CP070965.compsig"],"FileList":["/CP070965_BUILD_3.data","/CP070965.vmexe64","/CP070965.vmfile","/CP070965_VMw.zip","/CP070965.xml","/payload.json","/CP070965_VMw.zip/index.xml","/CP070965_VMw.zip/vendor-index.xml","/CP070965_VMw.zip/metadata.zip","/CP070965_VMw.zip/vib20/CP070965/HPE_bootbank_CP070965_HPG3.3-8.0.0.20613240.vib","/CP070965_VMw.zip/metadata.zip/vendor-index.xml","/CP070965_VMw.zip/metadata.zip/vmware.xml","/CP070965_VMw.zip/metadata.zip/vibs/CP070965--9132676996004971802.xml","/CP070965_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070965_HPG3.3-8.0.0.20613240.xml"],"Name":"CP070965.zip","SHA1Sum":"fb35fca5349fa508fba7abf4d29fe8c9a9275b28","SHA256Sum":"cf9e99f5f3d5e36f16636374f4f88e0212fa306b7cfba5057585c5b8470a6141","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3431-3030-304757554441"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070965","Version":"HPG3.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB014000GWUDA Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000GWUDA","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c142554cd76f48fba9ff8f98b1","SupportedDevices":["4d2340a5-3042-3431-3030-304757554441"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071617.zip","SHA1Sum":"01bb1918a82630020f4e87fa96267115f242d17b","SHA256Sum":"c0358e75b73d7ab0ab6c7467a0a53d4b142ee9565ca5c7bf6fd14f23810281e9","SHA512Sum":"20cce70ae6cd16f265723a1e4fa011c4ea5b860d86895d698d35509dc127c65b84da70309591fdc5aae9bcd5805ba2405d68dd50a2752fd7fcf0efec9ce94d16"}],"ComponentSizeInKB":240,"CompsigList":["cp071617.compsig"],"FileList":["/BCM-esx-8.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.zip","/BCM_bootbank_lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.vib","/cp071617.xml","/BCM-esx-8.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.zip/index.xml","/BCM-esx-8.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.zip/vendor-index.xml","/BCM-esx-8.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.zip/metadata.zip","/BCM-esx-8.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.vib","/BCM-esx-8.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/BCM-esx-8.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/BCM-esx-8.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/lsi-mr3-1143528017168839478.xml","/BCM-esx-8.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.738.04.00-1OEM.800.1.0.20613240.xml"],"Name":"cp071617.zip","SHA1Sum":"01bb1918a82630020f4e87fa96267115f242d17b","SHA256Sum":"c0358e75b73d7ab0ab6c7467a0a53d4b142ee9565ca5c7bf6fd14f23810281e9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd","20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"TypeOfChange":"1","Version":"2026.09.01","VibList":[{"Name":"lsi-mr3","Version":"7.738.04.00-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-lsi-mr3:7.738.04.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"lsi-mr3:7.738.04.00-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_33c570e0d3b346a3961025d28a","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U32","A43","A43","U61","A42","U60","U46","A43","A42","U65","U65","I46","U72","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-f36d4ef431-0.39-8.1.x86_64.rpm","SHA1Sum":"872ff0bb863964a87047485163fac701d47e0f3f","SHA256Sum":"4c1b76c1cf88cad95a8abe4cb096bcfb99a15c836e040343463ae8abcc3bc41a","SHA512Sum":"db1a2847b26a6fce7cf07b545065b177c942877fd2da09b820847bd1a3a732aaf4983542a414026a40167584f207b89eea6e4497aab2d477302fe20a2068c704"}],"ComponentSizeInKB":4978,"CompsigList":["firmware-smartarray-f36d4ef431-0.39-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/CP068825.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/Eaglescanyon-Release-0.39.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f36d4ef431-0.39-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068825.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068825.scexe"],"Name":"firmware-smartarray-f36d4ef431-0.39-8.1.x86_64.rpm","SHA1Sum":"872ff0bb863964a87047485163fac701d47e0f3f","SHA256Sum":"4c1b76c1cf88cad95a8abe4cb096bcfb99a15c836e040343463ae8abcc3bc41a","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Linux (x64) – HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ca06346fe34e428ca900a93a55","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U50","U50"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"CP071677.zip","SHA1Sum":"e07b4aa080ea3ba21cf7b97842dc834f99127e26","SHA256Sum":"12e1fb42b8f72bb9f7f2cbe14edcdd158d6df24c60839c0834fe81eacfb47429","SHA512Sum":"e539172aec80c99d79b7c3112e10913f12f1e9c43480e31c6cde6fcd7dcd89816dd36dd78b853a54306d8cec5f1ba22c03965f64da0808a5bcf59cfa12740fd8"}],"ComponentSizeInKB":30171,"CompsigList":["CP071677.compsig"],"FileList":["/CP071677.xml","/CP071677_VMw.zip","/payload.json","/CP071677.vmexe64","/CP071677.vmfile","/CP071677_VMw.zip/index.xml","/CP071677_VMw.zip/vendor-index.xml","/CP071677_VMw.zip/metadata.zip","/CP071677_VMw.zip/vib20/CP071677/HPE_bootbank_CP071677_1.0.0-8.0.0.21495797.vib","/CP071677_VMw.zip/metadata.zip/vendor-index.xml","/CP071677_VMw.zip/metadata.zip/vmware.xml","/CP071677_VMw.zip/metadata.zip/vibs/CP071677-7005355894148604731.xml","/CP071677_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071677_1.0.0-8.0.0.21495797.xml"],"Name":"CP071677.zip","SHA1Sum":"e07b4aa080ea3ba21cf7b97842dc834f99127e26","SHA256Sum":"12e1fb42b8f72bb9f7f2cbe14edcdd158d6df24c60839c0834fe81eacfb47429","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"},{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.10","VibList":[{"Name":"CP071677","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on VMware ESXi 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_db5ae8dbfb694cc99c9b73d4be","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071644.zip","SHA1Sum":"63e5872de17dc74f5c871250114f1c6326221aeb","SHA256Sum":"edc40f97f7eab7d05650f13ca78cb8de98f5c577ac2cde1af2959c935f30aa03","SHA512Sum":"74b8e14b461aed4406ecf3d34f82a590d506296d3a0665f58603eeeed81f24398ce9bf3e5078523b2b8e526e034633f73746da2ba7d8a366e19fb025eaf493d4"}],"ComponentSizeInKB":202,"CompsigList":["cp071644.compsig"],"FileList":["/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip","/BCM_bootbank_lsi-mr3_7.738.04.00-1OEM.900.0.24755229.vib","/cp071644.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/index.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/vendor-index.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.738.04.00-1OEM.900.0.24755229.vib","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip/vibs/lsi-mr3-4830308415655909628.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.xml"],"Name":"cp071644.zip","SHA1Sum":"63e5872de17dc74f5c871250114f1c6326221aeb","SHA256Sum":"edc40f97f7eab7d05650f13ca78cb8de98f5c577ac2cde1af2959c935f30aa03","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd","20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"TypeOfChange":"1","Version":"2026.09.01","VibList":[{"Name":"lsi-mr3","Version":"7.738.04.00-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-lsi-mr3:7.738.04.00-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"lsi-mr3:7.738.04.00-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_086c0ace5c284b75b8ea48754e","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U32","A43","A43","U61","A42","U60","U46","A43","A42","U65","U65","I46","U72","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"MicroserverGen10PlusSPS_05.01.05.216.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.216"}]},"Files":[{"Checksum":[{"Filename":"MicroserverGen10PlusSPS_05.01.05.216.fwpkg","SHA1Sum":"da15cedfc6d754ff8502fa64d446c87f5c9a49f8","SHA256Sum":"2c35c6309814c0348c4e8188851fe1b34ab157576fbaf1267e9a73ebed994242","SHA512Sum":"c3dfbac0c8891e19c93f416ae768859725dc11967f31db9521119da3f7465a0764701eb11f6af5fb98f8da36addc6ed00c9dc18b5a53f1184dc9a449e4245d02"}],"ComponentSizeInKB":8212,"CompsigList":[],"FileList":["MicroserverGen10PlusSPS_05.01.05.216.signed.bin","MicroserverGen10PlusSPS_05.01.05.216.xml","payload.json"],"Name":"MicroserverGen10PlusSPS_05.01.05.216.fwpkg","SHA1Sum":"da15cedfc6d754ff8502fa64d446c87f5c9a49f8","SHA256Sum":"2c35c6309814c0348c4e8188851fe1b34ab157576fbaf1267e9a73ebed994242","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.216"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE MicroServer Gen10 Plus","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10Plus","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aa8fd9f328dc48e9924f36712e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U48"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PS10x0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_U3_KPS10x0U3DK3.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b59464646","Version":"HPK3"},{"DeviceName":"SKHynix-PS10x0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_U3_KPS10x0U3DK3.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b59464554","Version":"HPK3"},{"DeviceName":"SKHynix-PS10x0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_U3_KPS10x0U3DK3.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b59464555","Version":"HPK3"},{"DeviceName":"SKHynix-PS10x0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_U3_KPS10x0U3DK3.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b59464645","Version":"HPK3"},{"DeviceName":"SKHynix-PS10x0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_U3_KPS10x0U3DK3.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b59464550","Version":"HPK3"},{"DeviceName":"SKHynix-PS10x0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_U3_KPS10x0U3DK3.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b59464551","Version":"HPK3"},{"DeviceName":"SKHynix-PS10x0_U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PS10x0_U3_KPS10x0U3DK3.HPb","InstallDurationSec":300,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3531-3336-304b59464552","Version":"HPK3"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PS10x0_U3_KPS10x0U3DK3.fwpkg","SHA1Sum":"d93434ec217455d869569c40136454e5186a71f8","SHA256Sum":"81bc4eacd5f37f46df1b788bab2322d38588d876bd851fc2486e613175795f65","SHA512Sum":"253888ffabf737212c24cd14391242fe14066aa992675bd845f8a3b3a72ba6ccc1e84b2a65194eed7b0e8bb717e464c24e378fc05dd14c5d4ee8cf8744fefd84"}],"ComponentSizeInKB":9821,"CompsigList":[],"FileList":["payload.json","SKHynix_PS10x0_U3_KPS10x0U3DK3.HPb","SKHynix_PS10x0_U3_KPS10x0U3DK3.xml"],"Name":"SKHynix_PS10x0_U3_KPS10x0U3DK3.fwpkg","SHA1Sum":"d93434ec217455d869569c40136454e5186a71f8","SHA256Sum":"81bc4eacd5f37f46df1b788bab2322d38588d876bd851fc2486e613175795f65","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-304b59464646","4d2340a5-304f-3330-3230-304b59464554","4d2340a5-304f-3630-3430-304b59464555","562340a5-304f-3130-3932-304b59464645","562340a5-304f-3330-3834-304b59464550","562340a5-304f-3730-3638-304b59464551","562340a5-304f-3531-3336-304b59464552"],"TypeOfChange":"1","Version":"HPK3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MO001600KYFFF, MO003200KYFET, MO006400KYFEU, VO001920KYFFE, VO003840KYFEP, VO007680KYFEQ and VO015360KYFER","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"MO001600KYFFF","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KYFET","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KYFEU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KYFFE","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KYFEP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KYFEQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO015360KYFER","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f74b93045b324f49bae87a2668","SupportedDevices":["562340a5-304f-3531-3336-304b59464552","562340a5-304f-3730-3638-304b59464551","562340a5-304f-3330-3834-304b59464550","562340a5-304f-3130-3932-304b59464645","4d2340a5-304f-3630-3430-304b59464555","4d2340a5-304f-3330-3230-304b59464554","4d2340a5-304f-3130-3630-304b59464646"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","9.0","16.0","10.0","26.04","22.04"]},{"OS":"VMware","Version":["8.0","9.0","9.1"]},{"OS":"Azure","Version":["10.0.26100.26100","10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A41_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a41-3.80_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"863476cbf2d3daa8925f205d0013ebd3dc2691f1","SHA256Sum":"537bdba65dd5ca25230edc9e4be2c1c3f3edf8705e129c4ba72d5e1794548a7a","SHA512Sum":"b47296156dd17511ee079e86626c56c798dd7c012b3a2a2859792a02a41f6c5573e22e2d0980d965211c299a195169219e23c13cda5ee0ad8b980cad3142f3ea"}],"ComponentSizeInKB":17520,"CompsigList":["firmware-system-a41-3.80_2026_05_28-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/A41_3.80_05_28_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/CP072020.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a41-3.80_2026_05_28-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072020.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072020.scexe"],"Name":"firmware-system-a41-3.80_2026_05_28-1.1.x86_64.rpm","SHA1Sum":"863476cbf2d3daa8925f205d0013ebd3dc2691f1","SHA256Sum":"537bdba65dd5ca25230edc9e4be2c1c3f3edf8705e129c4ba72d5e1794548a7a","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL325 Gen10 (A41) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_baf932484c904f228a81c0690d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A41"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u8.x86_64.rpm","SHA1Sum":"e8ca88559175a57c3b89dc84357e58d5f349bc01","SHA256Sum":"a1015142fd81ba2106cb0375004e172b87a40a585912c2c7d43193d63ebcdc51","SHA512Sum":"6fd19e27f3ea0de57108589be7fe6c8d30ea9d593f56f4f7263444a568be86088b388c9b67e41d9d613cd753c77f20adedaa95924f95f176e7897ce3b7b8b48b"}],"ComponentSizeInKB":2643,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u8.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/.build-id","./usr/lib/.build-id/06","./usr/lib/.build-id/06/c91c827e1c797a4ecb27d3e6a56d84b74d22df","./usr/lib/.build-id/10","./usr/lib/.build-id/10/d947fac5ec503d927e58fdfa821a634829738e","./usr/lib/.build-id/16","./usr/lib/.build-id/16/bfa88252e0d166cd5142998f8e863fe0c8fff8","./usr/lib/.build-id/1e","./usr/lib/.build-id/1e/f05f986f49aa67602464f7e33bf768f1614fae","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/48767f2130a07febc84c74cb5fa7a9620e64de","./usr/lib/.build-id/40","./usr/lib/.build-id/40/a3981455e5891a562f0fd698351a0f02bba6ae","./usr/lib/.build-id/4a","./usr/lib/.build-id/4a/0e36cb854a52462d7e096baf4fd6efaa3af81f","./usr/lib/.build-id/4f","./usr/lib/.build-id/4f/528ea5eb8f7481b97d12c44e480dd4d3e36026","./usr/lib/.build-id/60","./usr/lib/.build-id/60/26c9c6dafc8ae663e32176881a01f7b2c950ee","./usr/lib/.build-id/64","./usr/lib/.build-id/64/22de79525b447ddb1448745f5d8635f9e32fcb","./usr/lib/.build-id/69","./usr/lib/.build-id/69/e6b7a70d8da5c1666fce5e0fc1e1e1a8659184","./usr/lib/.build-id/87","./usr/lib/.build-id/87/f7169e8759f0e55131800404777eff6aa87655","./usr/lib/.build-id/88","./usr/lib/.build-id/88/7f1fd08f5cf3bc68002b8e4d98041e537bd2d9","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/4d69ff3b5f35a79957a59da55975a9fb1f7eab","./usr/lib/.build-id/91","./usr/lib/.build-id/91/03097315ab544a74dd3027ff83d1ddf7d12640","./usr/lib/.build-id/94","./usr/lib/.build-id/94/8aad76812eeaf5cf8dfea3b66aaeec21c00b3c","./usr/lib/.build-id/a3","./usr/lib/.build-id/a3/aac8cc43a7b1ae248e693e47d5b17298f52127","./usr/lib/.build-id/a7","./usr/lib/.build-id/a7/b1abfeaa9011b0db9af18f2b3be92b6eecdc2f","./usr/lib/.build-id/ad","./usr/lib/.build-id/ad/c70fdf8790b5999a7b560aac69680db7ed2fe7","./usr/lib/.build-id/c0","./usr/lib/.build-id/c0/ff1f3f8335059454c4aabac82dc7040fa04881","./usr/lib/.build-id/cd","./usr/lib/.build-id/cd/0c01094285274e728b2160a1cce6afb805bc12","./usr/lib/.build-id/df","./usr/lib/.build-id/df/8140d774c81739357a45be24834702d609e668","./usr/lib/.build-id/e2","./usr/lib/.build-id/e2/4e91897066b8f592a295c0a7fba68dfec65156","./usr/lib/.build-id/f5","./usr/lib/.build-id/f5/92e5dfc914e9e6ba53a93380a805d39f77e168","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.8.84","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/libibverbs","./usr/share/doc/libibverbs/libibverbs.md","./usr/share/doc/librdmacm","./usr/share/doc/librdmacm/librdmacm.md","./usr/share/doc/libvma","./usr/share/doc/libvma/CHANGES","./usr/share/doc/libvma/README","./usr/share/doc/mlnx-ofa_kernel","./usr/share/doc/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/mlnx-tools","./usr/share/doc/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/perftest","./usr/share/doc/perftest/COPYING","./usr/share/doc/perftest/README","./usr/share/doc/perftest/runme","./usr/share/doc/rdma-core","./usr/share/doc/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/rdma-core/README.md","./usr/share/doc/rdma-core/tag_matching.md","./usr/share/doc/rdma-core/udev.md","./usr/share/licenses/libvma","./usr/share/licenses/libvma/LICENSE","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.rhel9u8.x86_64.rpm","SHA1Sum":"e8ca88559175a57c3b89dc84357e58d5f349bc01","SHA256Sum":"a1015142fd81ba2106cb0375004e172b87a40a585912c2c7d43193d63ebcdc51","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u8.x86_64.rpm","SHA1Sum":"1cbb681c14dfad107362c2638e195ecd906259a5","SHA256Sum":"f4866970c64ec0fb63952adbe851982b93db9d9e83ac723bbe4d9b777f8655f8","SHA512Sum":"f71c71a7135b14dbc32e30d71082bfaf38138570ca0b8783be2d06bd6f439e0b2b8e541622ad74e8629a26758dc572ce888dc5898402cd2cd899a985f45f162f"}],"ComponentSizeInKB":2715,"CompsigList":["kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/zz01-mlnx-ofa_kernel-bnxt_re.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-cifs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-efa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-hfi1.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ipoib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_iser.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_isert.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srp.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_srpt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_umad.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-ib_uverbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-irdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-iw_cxgb4.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mana_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx4_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5-vfio-pci.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_core.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_dpll.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_fwctl.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_ib.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx5_vdpa.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlx_compat.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxdevm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxfw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-mlxsw_spectrum.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvme-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-nvmet-rdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-opa_vnic.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-qedr.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_cm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_rxe.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdma_ucm.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rdmavt.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-rpcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-siw.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-svcrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-usnic_verbs.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-vmw_pvrdma.conf","./etc/depmod.d/zz01-mlnx-ofa_kernel-xprtrdma.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/compat","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/compat/mlx_compat.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_cm.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_core.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_ucm.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_umad.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/iw_cm.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_cm.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/efa/efa.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/sw/siw/siw.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/host/nvme-rdma.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/fs","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/fs/cifs","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/fs/cifs/cifs.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/mlxdevm/mlxdevm.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/mlnx-ofa_kernel/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/704e7abc42177e2128d40dc318b88925f98a5b","./usr/lib/.build-id/08/dd9a21622b0d24503f8e5d58b35229ed243ac5","./usr/lib/.build-id/11","./usr/lib/.build-id/11/2ed8a9e4ea240ea679404b86dfb04f9a015c56","./usr/lib/.build-id/11/fd74195d6842dd2df66899133cc608a34847a3","./usr/lib/.build-id/18","./usr/lib/.build-id/18/0f8330d95e3b996c48aa56aee926936cd8600c","./usr/lib/.build-id/1b","./usr/lib/.build-id/1b/7467b922167fd19742666d2ea73e27cac32b50","./usr/lib/.build-id/24","./usr/lib/.build-id/24/ebc0db87f796dbae31c7d2b4331d6419cd98fc","./usr/lib/.build-id/27","./usr/lib/.build-id/27/d9bad8ce91cdfa2f95bc61b69bcba4200cbfae","./usr/lib/.build-id/2a","./usr/lib/.build-id/2a/b1f426e239840c6547dc5f79526cbf4f2ebaec","./usr/lib/.build-id/2b","./usr/lib/.build-id/2b/58e4aa7b640e1ae26753eb13d59a8781c80dcf","./usr/lib/.build-id/2c","./usr/lib/.build-id/2c/d6961b34ffdedfd2a82fa09473fa653930d282","./usr/lib/.build-id/31","./usr/lib/.build-id/31/0d36f4c9f88fdaacdb5358480974075e6e0006","./usr/lib/.build-id/35","./usr/lib/.build-id/35/657bd534ca0482a8565ec411c7b77af01d9a31","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/c71248c8147c91d07362df9fdb6efe6e8448c7","./usr/lib/.build-id/40","./usr/lib/.build-id/40/79a2f16e5a4112c87168f2c50860dea894fef6","./usr/lib/.build-id/4e","./usr/lib/.build-id/4e/0061b424d0bddd091b89b586fb7de125434263","./usr/lib/.build-id/54","./usr/lib/.build-id/54/dd5db0fb4052a3e14b0335c66e1ddb7ed11bf3","./usr/lib/.build-id/55","./usr/lib/.build-id/55/33b3011d9213b54e2809111b19a05b52a45988","./usr/lib/.build-id/59","./usr/lib/.build-id/59/bbef9ef8ca2184f1bec652844feb33f55d57cd","./usr/lib/.build-id/5c","./usr/lib/.build-id/5c/04edf9e06aa03794a53d91a24b8e434f4f06c9","./usr/lib/.build-id/5f","./usr/lib/.build-id/5f/ef79c08865897850f9f47f1f0503920c46b790","./usr/lib/.build-id/60","./usr/lib/.build-id/60/9a5534a3cf0abe9e29d4d8f7a4acc6546918ad","./usr/lib/.build-id/64","./usr/lib/.build-id/64/2fdda65b4cee529fb9c6e1b2b60548b69205aa","./usr/lib/.build-id/67","./usr/lib/.build-id/67/5906bbf1f17ab4e67102956cfbc531fd07ad98","./usr/lib/.build-id/69","./usr/lib/.build-id/69/4df5828387e42ffe71477fbd9f28fc5f4faa1b","./usr/lib/.build-id/6e","./usr/lib/.build-id/6e/134c5ec72437de490b8415db3a9c24d1c172cc","./usr/lib/.build-id/88","./usr/lib/.build-id/88/fb6c119c9034313c984ab88116493149b68a18","./usr/lib/.build-id/8e","./usr/lib/.build-id/8e/83d3263da0b6445fd3d31e7826fd729778d04b","./usr/lib/.build-id/9c","./usr/lib/.build-id/9c/f23d4d4ddd07d475bed11352eda3251433de84","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/a1a140e5b0b6c5b71862490069943e2776cdd2","./usr/lib/.build-id/a4","./usr/lib/.build-id/a4/e95ccd26a792b1a7565af25a71655fad3ec8fd","./usr/lib/.build-id/a8","./usr/lib/.build-id/a8/4b7a1a0c50dd4c0580a11c12902d1234fbbd3c","./usr/lib/.build-id/a8/6df975ea6a35a50eb32e4597c41c2b92fb297c","./usr/lib/.build-id/aa","./usr/lib/.build-id/aa/04812e399cbf42aea028ca47dc829159ec0282","./usr/lib/.build-id/b4","./usr/lib/.build-id/b4/ab62442cf7e5a354464caf9a5d103fc5ec80e6","./usr/lib/.build-id/bc","./usr/lib/.build-id/bc/a460e026689be91cf56baa1032d0f0710d429b","./usr/lib/.build-id/ce","./usr/lib/.build-id/ce/e7cb3e5d8856b462f587d6b30b92478233640c","./usr/lib/.build-id/d7","./usr/lib/.build-id/d7/a8999f885763bdf22eb83250e2b8914f69a0ff","./usr/lib/.build-id/df","./usr/lib/.build-id/df/0eba2667ad94e10eae316fde83e13dd080c466","./usr/lib/.build-id/f1","./usr/lib/.build-id/f1/414cef0eff85233c68c01fbe94315a191ea9c2","./usr/lib/.build-id/f3","./usr/lib/.build-id/f3/429b39317410fa16b9d6807774c1443677eee5","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/52f18148e62297e981f1f128ae33c0c6e09ee3","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/44246158db13feeec8773362228955f1d8b02a","./usr/share/smartupdate/kmod-mlnx-ofa_kernel/component.xml"],"Name":"kmod-mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.1.rhel9u8.x86_64.rpm","SHA1Sum":"1cbb681c14dfad107362c2638e195ecd906259a5","SHA256Sum":"f4866970c64ec0fb63952adbe851982b93db9d9e83ac723bbe4d9b777f8655f8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9ec3e2fdd81"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 9 x86_64)","OSVersion":{"Name":"Linux","Value":"6.9"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 6 Update 10 x86_64)","OSVersion":{"Name":"Linux","Value":"6.10"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 4 x86_64)","OSVersion":{"Name":"Linux","Value":"7.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (Red Hat Enterprise Linux 7 Update 5 x86_64)","OSVersion":{"Name":"Linux","Value":"7.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for Red Hat Enterprise Linux 9 Update 8 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_763c62076fe64fec9f3e5d02bd","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","A72","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071618.zip","SHA1Sum":"5d97eec89332f4ed425cb2d801c34cf3160f4d54","SHA256Sum":"fd7a91cbe0a026e631c98e49e36b3bbd53461d1ca83db2fe13eeab512a4658a9","SHA512Sum":"a33c5518ff36c965e64ad70b881df66d3b02a7039019c9bc8b8f064beee46ea32e784965c80e3a077820d89ca6c6e4a501662f2977635283d20ec0e7a05c88f7"}],"ComponentSizeInKB":203,"CompsigList":["cp071618.compsig"],"FileList":["/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip","/BCM_bootbank_lsi-mr3_7.738.04.00-1OEM.900.0.24755229.vib","/cp071618.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/index.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/vendor-index.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/vib20/lsi-mr3/BCM_bootbank_lsi-mr3_7.738.04.00-1OEM.900.0.24755229.vib","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip/vibs/lsi-mr3-4830308415655909628.xml","/BCM-esx-9.0.0-Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Broadcom-lsi-mr3_7.738.04.00-1OEM.900.0.24755229.xml"],"Name":"cp071618.zip","SHA1Sum":"5d97eec89332f4ed425cb2d801c34cf3160f4d54","SHA256Sum":"fd7a91cbe0a026e631c98e49e36b3bbd53461d1ca83db2fe13eeab512a4658a9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec8d473edd","20a6e8e4-bf33-4c71-a6bf-d9ec5f2989ba"],"TypeOfChange":"1","Version":"2026.09.01","VibList":[{"Name":"lsi-mr3","Version":"7.738.04.00-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus Controllers and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 Controllers Driver (64-bit) for vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"Broadcom-lsi-mr3:7.738.04.00-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"lsi-mr3:7.738.04.00-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1d46277dceaf4f53882420780e","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U32","A43","A43","U61","A42","U60","U46","A43","A42","U65","U65","I46","U72","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE 12Gb SAS Expander Card","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"firmware-Signed-5.15-build-000.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c097d8f0","Version":"5.15"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-1f19a4a64d_5.15-2.1_amd64.deb","SHA1Sum":"ce35ff97b5281b74988e4f7fece31a08c2bafd73","SHA256Sum":"8231942422d5cd383457895f658bdfd8d969e45c81786d79abd3cab15ddd7ff5","SHA512Sum":"6cd1ae627c50e3357a9f8a3d90a376987b1cff061f037bc15eec6ad1375b0d380622d8e3f88a024069657b31503aee455e783a1d7fb23890c323f696a8ffd2f5"}],"ComponentSizeInKB":3383,"CompsigList":["firmware-smartarray-1f19a4a64d_5.15-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/CP071713.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/firmware-Signed-5.15-build-000.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071713.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-1f19a4a64d-5.15-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071713.scexe"],"Name":"firmware-smartarray-1f19a4a64d_5.15-2.1_amd64.deb","SHA1Sum":"ce35ff97b5281b74988e4f7fece31a08c2bafd73","SHA256Sum":"8231942422d5cd383457895f658bdfd8d969e45c81786d79abd3cab15ddd7ff5","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18c097d8f0"],"TypeOfChange":"1","Version":"5.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Supplemental Update / Online ROM Flash Component for Ubuntu – HPE 12Gb/s SAS Expander Firmware for HPE Smart Array Controllers and HPE HBA Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"12G SAS Exp Card","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7131ee6d05744824b0805744c4","SupportedDevices":["422340a5-3939-4644-4237-342d07f65795"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A40","U30","P89","U41","A42","U46","U46","A43","A42","A43","A43","A42","U31"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.14"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.14"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.02"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//bk020502.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.02"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.14"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//mh021114.bin","InstallDurationSec":250,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.14"}]},"Files":[{"Checksum":[{"Filename":"cp072110.exe","SHA1Sum":"a11fb67c888b081bcc7dbb9e3ed0a7c5b9dffaf9","SHA256Sum":"69f72a0a9ad8eefb74d4a2f21b149806e284db9e0b2ad41d36d577474b189967","SHA512Sum":"d8d4a6605828c4c2ad6106748cece5df6117478843fc4c60310f8b0597ed34c32c4ebc6ddd67655c87a517a0ca3f04d932aab4ea9540a446a4a8c2af16a74076"}],"ComponentSizeInKB":3774,"CompsigList":["cp072110.compsig"],"FileList":["QLAFWUpdate.exe","adapters.properties","bk020502.bin","cp072110.xml","cpqsetup.exe","hbaapi2_x64.dll","installer.dll","mh021114.bin","payload.json","ql2xhai2.dll","qlafwupdate.properties","qlafwupdate.txt","qlcoutil.dll","qlsdm.dll","reference.xml","runquery.bat","x103Cx1939/BC26xx.DAT","x103Cx1939/FWA83xxB.DAT","x1590x00F9/PEP27BC.dat","x1590x00F9/Q27FBC.dat","x1590x00F9/Q27FWA.dat","x1590x00FA/PEP27BC.dat","x1590x00FA/Q27FBC.dat","x1590x00FA/Q27FWA.dat","x1590x0203/PEP27BC.dat","x1590x0203/Q27FBC.dat","x1590x0203/Q27FWA.dat","x1590x0204/PEP27BC.dat","x1590x0204/Q27FBC.dat","x1590x0204/Q27FWA.dat","x1590x022D/PEP27BC.dat","x1590x022D/Q27FBC.dat","x1590x022D/Q27FWA.dat"],"Name":"cp072110.exe","SHA1Sum":"a11fb67c888b081bcc7dbb9e3ed0a7c5b9dffaf9","SHA256Sum":"69f72a0a9ad8eefb74d4a2f21b149806e284db9e0b2ad41d36d577474b189967","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.06.02"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters - Microsoft Windows Server 2022 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":250,"RebootRequired":"yes","SWKeys":[{"Name":"qlogic","SWKeyExpectedPath":"firmware:qlogic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7a716a33c1994ec0bf295c6268","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070987.zip","SHA1Sum":"bca5296d0f9541698bfe7db46376533b7b7423d2","SHA256Sum":"79c8f1b0337be9579def423a3ba2b64621e61560b2b37331bd1e7a3d1fe2c9ba","SHA512Sum":"05e908a72fe9332ea50d610f3222c9c360196d6b577ec43b06f832e6058a02556982a7c70c903b90da0f51889f04d65f7792927b6b07535f4fd45c739fa7b2bc"}],"ComponentSizeInKB":32,"CompsigList":["cp070987.compsig"],"FileList":["/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip","/cp070987.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/index.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/vib20/nmst/MEL_bootbank_nmst_4.34.1.11-1OEM.900.0.24755229.vib","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip/vibs/nmst-5319458696017701934.xml","/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Mellanox-NATIVE-NMST_4.34.1.11-1OEM.900.0.24755229.xml"],"Name":"cp070987.zip","SHA1Sum":"bca5296d0f9541698bfe7db46376533b7b7423d2","SHA256Sum":"79c8f1b0337be9579def423a3ba2b64621e61560b2b37331bd1e7a3d1fe2c9ba","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec89537299","20a6e8e4-bf33-4c71-a6bf-d9ecd0345028"],"TypeOfChange":"1","Version":"2026.02.23","VibList":[{"Name":"nmst","Version":"4.34.1.11-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"net-mst kernel module driver component for VMware ESXi 9uX","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"nmst:4.34.1.11-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"Mellanox-NATIVE-NMST:4.34.1.11-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ebb932514aa840c6ba553450ad","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1007103c8020","a6b1a447-382a-5a4f-15b3-1007103c801f","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-1007103c22f4","a6b1a447-382a-5a4f-15b3-1007103c22f2","a6b1a447-382a-5a4f-15b3-1007103c22f3","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-1007103c22f5","a6b1a447-382a-5a4f-15b3-1007103c22f1","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101315900221"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","I38","I41","I36","U34","U17","U34","P85","P89","U30","P89","U32","P89","U31","U20","U31","U20","U36","P86","U15","U15","U22","U41","P92","P99","U40","U21","U38","U38","I36","HPE Apollo 6500 Gen10 Plus (Chassis)","U19","U56","U61","U45","U25","U37","U24","U13","U12","U13","U14","U14","HPE Apollo sx40 Server","HPE Apollo pc40 Server","HPE Apollo kl20 Server","HPE Apollo am35 Server","I40","I43","I39","I40","I42","I37"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U56","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U56_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000239","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u56-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"5841886ab6018b603211a0d08458040ba925c20c","SHA256Sum":"aba96c9c49acd041b3aab21b97be82c5d84fe1f3063d1985a15331b6c3ec3033","SHA512Sum":"ae5a611bbca9e38f89794726b0cd5e177bd44cf8453359aa3b1ac3b7b7b00cf0bd3e250c8ed70ed04b64df863c4266314b404cd64f8e6bcc8edbb4cf135d9014"}],"ComponentSizeInKB":33317,"CompsigList":["firmware-system-u56-2.70_2026_08_19-1.1.x86_64_part2.compsig","firmware-system-u56-2.70_2026_08_19-1.1.x86_64_part1.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.70_2026_08_19-1.1/CP073099.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.70_2026_08_19-1.1/U56_2.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u56-2.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073099.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073099.scexe"],"Name":"firmware-system-u56-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"5841886ab6018b603211a0d08458040ba925c20c","SHA256Sum":"aba96c9c49acd041b3aab21b97be82c5d84fe1f3063d1985a15331b6c3ec3033","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000239"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE DL110 Gen10 Plus Telco (U56) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U56","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cfa735d358ee4a9c887c47d20d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U56","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Ethernet 200Gb 1-port QSFP56 MCX623105AS-VDAT Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"22_49_1014-MCX623105AS-VDA_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101d15b30040","Version":"22.49.1014"}]},"Files":[{"Checksum":[{"Filename":"22_49_1014-MCX623105AS-VDA_Ax.pldm.fwpkg","SHA1Sum":"e6ff510b438315442d05e329025e4ce5446fe768","SHA256Sum":"5b29dc816a95ea62b7d1ba611ab171d55ed23d95b5ebd1d51245440ec6fe12f8","SHA512Sum":"e2649e8fa768b1bb0742634c7ab901835da751332623bdda2facf35f3b460745ea77593085abd7a4affd8519752184f37b70706cdc432d8e8c44026435e50e09"}],"ComponentSizeInKB":7717,"CompsigList":[],"FileList":["22_49_1014-MCX623105AS-VDA_Ax.pldm.signed","22_49_1014-MCX623105AS-VDA_Ax.pldm.xml","payload.json"],"Name":"22_49_1014-MCX623105AS-VDA_Ax.pldm.fwpkg","SHA1Sum":"e6ff510b438315442d05e329025e4ce5446fe768","SHA256Sum":"5b29dc816a95ea62b7d1ba611ab171d55ed23d95b5ebd1d51245440ec6fe12f8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"TypeOfChange":"1","Version":"22.49.1014"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for Mellanox MCX623105AS-VDAT Ethernet 200Gb 1-port QSFP56 Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ca0d92b413c840778ce6748f61","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U62","U63","A55","A55","A56","A56","U59","U58","A59"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072270.exe","SHA1Sum":"8de8b3a70179b9fb93858e757f64c7e03b7b53ba","SHA256Sum":"ed54a9fdc37812dffb2762202fb151d443b784b0c50c507b253773b1b09e28ce","SHA512Sum":"2666e54977d8784021eee124b3f91bed24512128193f7707f2e0a98e4712e32a5f705a060dcbc3b9edfa8dbddd74134ac7a94b3548a24624af0ebdaf8fc90f83"}],"ComponentSizeInKB":1230,"CompsigList":["cp072270.compsig"],"FileList":["cp072270.xml","cpqsetup.exe","cp_data.xml","i40ea68.cat","i40ea68.din","i40ea68.inf","i40ea68.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp072270.exe","SHA1Sum":"8de8b3a70179b9fb93858e757f64c7e03b7b53ba","SHA256Sum":"ed54a9fdc37812dffb2762202fb151d443b784b0c50c507b253773b1b09e28ce","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532"],"TypeOfChange":"1","Version":"1.25.113.0"}],"InstallationDependency":{},"Name":"HPE Intel i40ea Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40ea68.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_989777fca94e4213b0c40fbeef","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572103C0000","a6b1a447-382a-5a4f-8086-158A15900000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp068650.exe","SHA1Sum":"ba46621b84faaedee4245d5565d825d7b6e6d6f4","SHA256Sum":"f9d5f1710756a94fb07262d2f72699271b7cb6c170b7a34bf763c2f2195c4616","SHA512Sum":"2789275918626bffcc89f9ef150b2265566ac37e3fe244a1e3f260fe8677d0a856b79ec25b6b8357674cdb4c1d3290fb5076ab4214a7eb7f4104c42382c59eb3"}],"ComponentSizeInKB":3924,"CompsigList":["cp068650.compsig"],"FileList":["cp068650.xml","cpqsetup.exe","KAPM6ALSHPD5.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068650.exe","SHA1Sum":"ba46621b84faaedee4245d5565d825d7b6e6d6f4","SHA256Sum":"f9d5f1710756a94fb07262d2f72699271b7cb6c170b7a34bf763c2f2195c4616","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_24c1872edd3c444aab7090b24f","SupportedDevices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","562340a5-304f-3531-3330-305058444256","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL8CBA0HPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8b26d1ef02_0HPD3-2.1_amd64.deb","SHA1Sum":"0fdeef1525cf509f6e23a69a2eb2205be9ac2250","SHA256Sum":"04d11ddec2855d219a1d1949a052b4542aa4ab0638c01861bc964403a84fcc83","SHA512Sum":"b2019cc941835413f91ab97bb0cedbc29b20e1db301ac6f06aadea6064a4a356354c5adb411b27875181c555f5b50c1449ead54269f10adc1c6a0c272e16b2b5"}],"ComponentSizeInKB":4559,"CompsigList":["firmware-hdd-8b26d1ef02_0HPD3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/CP073255.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/WVL8CBA0HPD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073255.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073255.scexe"],"Name":"firmware-hdd-8b26d1ef02_0HPD3-2.1_amd64.deb","SHA1Sum":"0fdeef1525cf509f6e23a69a2eb2205be9ac2250","SHA256Sum":"04d11ddec2855d219a1d1949a052b4542aa4ab0638c01861bc964403a84fcc83","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB008000JWRTD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c816526ef2cc4dfc938efb7cd8","SupportedDevices":["4d2340a5-3042-3830-3030-304a57525444"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-805abb7e9c-85032G00-13.1.x86_64.rpm","SHA1Sum":"8f1571bfeda95b7a465d39e22ca1b98047b22d50","SHA256Sum":"706d9b4aa33867604d31011fc21bacccdec0223524925883b7fd3a56be01fe38","SHA512Sum":"3aa9704ca240cca34dab8513c4db1ebd244c33ffe380caaec7dbea3cb08dff361b7c195bd65a6aadaf11baab12386d09f64e0cb7ff8a4059ad8c56a74d9d3e42"}],"ComponentSizeInKB":7527,"CompsigList":["firmware-hdd-805abb7e9c-85032G00-13.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/85032G00_mp.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/CP068910.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-805abb7e9c-85032G00-13.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068910.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068910.scexe"],"Name":"firmware-hdd-805abb7e9c-85032G00-13.1.x86_64.rpm","SHA1Sum":"8f1571bfeda95b7a465d39e22ca1b98047b22d50","SHA256Sum":"706d9b4aa33867604d31011fc21bacccdec0223524925883b7fd3a56be01fe38","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3438-304b58414c42"],"TypeOfChange":"1","Version":"85032G00"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_25502ba383f94660b9ac0d565f","SupportedDevices":["562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3030-3438-304b58414c42"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Toshiba-MG08Air-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Toshiba_MG08Air_TAMG08ADAnG3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3430-3030-3047575a5654","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"Toshiba_MG08Air_TAMG08ADAnG3.fwpkg","SHA1Sum":"fde1ea65f338efa599f73c4ba2d71e02e92ffbf2","SHA256Sum":"c6bb621e978e8c5760bdefa134779c4265431722a3e5060d37f52eaf60bfea4a","SHA512Sum":"c2a0008f42757f359b3fc7337809d2da708d86102fcaa3eca3f349a873341dd533d93c96802da34b79bccd8c1dae5da72464cb7ba0f6e0862602f3d17cf03316"}],"ComponentSizeInKB":1242,"CompsigList":[],"FileList":["payload.json","Toshiba_MG08Air_TAMG08ADAnG3.HPb","Toshiba_MG08Air_TAMG08ADAnG3.xml"],"Name":"Toshiba_MG08Air_TAMG08ADAnG3.fwpkg","SHA1Sum":"fde1ea65f338efa599f73c4ba2d71e02e92ffbf2","SHA256Sum":"c6bb621e978e8c5760bdefa134779c4265431722a3e5060d37f52eaf60bfea4a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047575a5654"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MB004000GWZVT","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWZVT","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9077ed7856b1465a8395a8ce4b","SupportedDevices":["4d2340a5-3042-3430-3030-3047575a5654"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8f501d6cf1_0HPD4-2.1_amd64.deb","SHA1Sum":"7d6873b3e5a6870916735e9d932d844adebbc20b","SHA256Sum":"36e516c917299af9ea44b5cec7adaeaae1e2818633b7784ebfef64f75f7d6939","SHA512Sum":"d374bdc47add5eb55f83f8b905da1b39eac725983378eb5f2d5da4a6ac43424eea948516a27152928350c8af9acdb636117ffbca66daa94de2bd1c22994a53ec"}],"ComponentSizeInKB":4452,"CompsigList":["firmware-hdd-8f501d6cf1_0HPD4-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/CP071755.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/KAPM6ALFHPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071755.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071755.scexe"],"Name":"firmware-hdd-8f501d6cf1_0HPD4-2.1_amd64.deb","SHA1Sum":"7d6873b3e5a6870916735e9d932d844adebbc20b","SHA256Sum":"36e516c917299af9ea44b5cec7adaeaae1e2818633b7784ebfef64f75f7d6939","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9f0d865638f1452fbdb337a725","SupportedDevices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.21"}]},"Files":[{"Checksum":[{"Filename":"firmware-fc-emulex-2026.06.01-1.4.x86_64.rpm","SHA1Sum":"f0e8ddf28119f2897c9eea2f987d14c1c542061c","SHA256Sum":"82c34f2b65d2512c266323a1c9accd4eec87951e4c4e39c07bc4d3c987784385","SHA512Sum":"0a908188de4a9ba8bf4fda79c5e593c383045425a2e2d2dabbbe9fb019de54c5c39f6677d81824269f6fe92c87ce900e3feff8ea5bfa2387318caa7dbfa8a28a"}],"ComponentSizeInKB":13947,"CompsigList":["firmware-fc-emulex-2026.06.01-1.4.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/.setup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/CP071319.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/elxflashStandalone-linux-14.4.731.21-1.zip","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/firmware","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/firmware/B14473121.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/firmware/P14473121.grp","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/fwmatrix.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/hpe_fw_matrix.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/payload.json","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/reference.xml","./usr/lib/x86_64-linux-gnu/firmware-fc-emulex-2026.06.01-1.4/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071319.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071319.scexe"],"Name":"firmware-fc-emulex-2026.06.01-1.4.x86_64.rpm","SHA1Sum":"f0e8ddf28119f2897c9eea2f987d14c1c542061c","SHA256Sum":"82c34f2b65d2512c266323a1c9accd4eec87951e4c4e39c07bc4d3c987784385","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ac5358a08e71413698d2d477d2","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770068","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770068","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770069","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770069","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770070","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770070","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770071","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770071","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770073","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770073","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770072","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770072","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770074","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770074","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770077","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770077","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770077","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770078","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-809010770078","Version":"8.65.31"},{"DeviceName":"Marvell FastLinQ adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ql_ah_mbi_open_8.65.31_pldm.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80f010770078","Version":"8.65.31"}]},"Files":[{"Checksum":[{"Filename":"ql_ah_mbi_open_8.65.31_pldm.fwpkg","SHA1Sum":"15730fdf2e1ea522067fc88f9a743e48c15004b9","SHA256Sum":"6c788d1613cfa43b11de18d00ee496a2057a21acfe61fcbaf63511a1e2b29ad0","SHA512Sum":"1f9573c1a6f8e14c3124c1b75a1fb8577c8518a418be5b222469792e3d33930267aec068acbbbb26aeff01d435d92e28139eb84872c5829a24ca104deb6685ba"}],"ComponentSizeInKB":1908,"CompsigList":[],"FileList":["payload.json","ql_ah_mbi_open_8.65.31_pldm.HPb","ql_ah_mbi_open_8.65.31_pldm.xml"],"Name":"ql_ah_mbi_open_8.65.31_pldm.fwpkg","SHA1Sum":"15730fdf2e1ea522067fc88f9a743e48c15004b9","SHA256Sum":"6c788d1613cfa43b11de18d00ee496a2057a21acfe61fcbaf63511a1e2b29ad0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-80f010770068","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-80f010770069","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-80f010770070","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-80f010770071","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-809010770073","a6b1a447-382a-5a4f-1077-80f010770073","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-80f010770072","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-80f010770074","a6b1a447-382a-5a4f-1077-807010770077","a6b1a447-382a-5a4f-1077-809010770077","a6b1a447-382a-5a4f-1077-80f010770077","a6b1a447-382a-5a4f-1077-807010770078","a6b1a447-382a-5a4f-1077-809010770078","a6b1a447-382a-5a4f-1077-80f010770078"],"TypeOfChange":"1","Version":"8.65.31"}],"InstallationDependency":{},"MinimumActiveVersion":"8.55.12","Name":"Marvell FastLinQ Firmware Package for Arrowhead adapters","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MARVELL_FLQ_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4c842fe47e1c4a31bbb03ff382","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","12.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","A47","A48","U46"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a27c95663d-HPK6-5.1.x86_64.rpm","SHA1Sum":"632a6f9f75c5931ff2c08c4b95d8499f00294996","SHA256Sum":"d55055e32976b6c3eb8b69dd7be1ef612b87771ff92bc58feff5ecd2e11f1e9a","SHA512Sum":"63bc80a83db727ac74fd14ed14befe101aee9462e1296567b483e75c9972f479f32260d9c0cada0d75c487be66c77aac34df281f8c3c8c84966efcf5d793f19a"}],"ComponentSizeInKB":7186,"CompsigList":["firmware-hdd-a27c95663d-HPK6-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/CP068916.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/GPM173XAHPK6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a27c95663d-HPK6-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068916.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068916.scexe"],"Name":"firmware-hdd-a27c95663d-HPK6-5.1.x86_64.rpm","SHA1Sum":"632a6f9f75c5931ff2c08c4b95d8499f00294996","SHA256Sum":"d55055e32976b6c3eb8b69dd7be1ef612b87771ff92bc58feff5ecd2e11f1e9a","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_378e98a7adff433fa1102dd3d4","SupportedDevices":["4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43","562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3815d4b024-GPK8-4.1.x86_64.rpm","SHA1Sum":"89067d369f8d26e3ed35b0fcae06c335633e21d1","SHA256Sum":"961034c61d8c6ac996e37e634db202b240665ee625e6e390360a6364ef923a81","SHA512Sum":"1654eed99f66dcfe3a01ef808a70fab3fb6bfce5811b669392df70302e295dd69cf29f75a7384f0fc51df22068b11413001e766e4815a9888adc95353089b8c6"}],"ComponentSizeInKB":6142,"CompsigList":["firmware-hdd-3815d4b024-GPK8-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/CP068921.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/KACM6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068921.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068921.scexe"],"Name":"firmware-hdd-3815d4b024-GPK8-4.1.x86_64.rpm","SHA1Sum":"89067d369f8d26e3ed35b0fcae06c335633e21d1","SHA256Sum":"961034c61d8c6ac996e37e634db202b240665ee625e6e390360a6364ef923a81","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e10cdbf81fd44dc998fb58d4e8","SupportedDevices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 568i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37CE15900215","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900216","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 369i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900247","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C339E","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C17D1","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 4-port 366T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C8157","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FC","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D2","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572103C22FD","Version":"11.1.7"},{"DeviceName":"HPE Ethernet 10Gb 2-port 562T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1563159000D1","Version":"10.55.3"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMSFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D315900219","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 368FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D115900217","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 563i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_FVL4HP.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1581159000F8","Version":"1.1375.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port 568FLR-MMT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37D215900218","Version":"1.4008.0"},{"DeviceName":"HPE Ethernet 1Gb 2-port 361i Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521103C337F","Version":"1.4008.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-intel-1.38.0-1.1.x86_64.rpm","SHA1Sum":"5e996bc57624f9fc73719ca83e56d47d77304c5c","SHA256Sum":"c8eee5890978cb99f3c20d922f23c87d4fe1d3806093cab012e8b1ce9673b364","SHA512Sum":"7967466114a3617faf3e88a548e5018458487c4e2a6a14bb627857d6c4abb77b2a58989359067bbd21f81f705154cac4a4a50c1480eb17b5bc3a9144d337bfb0"}],"ComponentSizeInKB":10182,"CompsigList":["firmware-nic-intel-1.38.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/CP072303.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/CP072303.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/BootIMG_FVL4HP.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_361T.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_361T_H65030-003_2.25_80001147.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_361i_I350_2p_Cu_NCSI_1.61_WOL_8000119A.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_366FLR_G41713-00x_800011A1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_366FLR_G41713-00x_800011A1.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_366T_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_366T_Quad_H73104-00x_800011F1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_366T_Quad_H73104-00x_800011F1.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_369i_88E1512_P01_88E1512_P23_NCSI_6p00_80003AC3.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_40G_Adapter_562FLR-SFP_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_40G_Adapter_KR_VPD_MAP_FVL4HP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_40G_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_562FLR-SFP_DP_H47655-000_11p1p7_9p50_8000F231.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_562FLR-T_B0_AT2_10p55p3_3p30_800016F1.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_562SFP_DP_H44490-000_11p1p7_9p50_8000F232.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_562T_B0_AT2_MCTP_10p55p3_3p30_800016EF.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_563i_KR_DP_800035C0.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_568i_Backplane_2x10G_P01_NCSI_6p00_80003AC4.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_Apollo_PHY_Auto_Detect_NCSI_6p00_80003AC2.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_DL160_PHY_Auto_Detect_P01_88E1512_P23_NCSI_6p00_80003AC5.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_568i_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_FVL_FPK_Adapter_LOM_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_XG_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/HPE_XG_SGVL_Adapter_VPD_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-intel-1.38.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072303.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072303.scexe"],"Name":"firmware-nic-intel-1.38.0-1.1.x86_64.rpm","SHA1Sum":"5e996bc57624f9fc73719ca83e56d47d77304c5c","SHA256Sum":"c8eee5890978cb99f3c20d922f23c87d4fe1d3806093cab012e8b1ce9673b364","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37CE15900215","a6b1a447-382a-5a4f-8086-37D115900216","a6b1a447-382a-5a4f-8086-37D115900247","a6b1a447-382a-5a4f-8086-1521103C339E","a6b1a447-382a-5a4f-8086-1521103C17D1","a6b1a447-382a-5a4f-8086-1521103C8157","a6b1a447-382a-5a4f-8086-1572103C22FC","a6b1a447-382a-5a4f-8086-1563159000D2","a6b1a447-382a-5a4f-8086-1572103C22FD","a6b1a447-382a-5a4f-8086-1563159000D1","a6b1a447-382a-5a4f-8086-37D315900219","a6b1a447-382a-5a4f-8086-37D115900217","a6b1a447-382a-5a4f-8086-1581159000F8","a6b1a447-382a-5a4f-8086-37D215900218","a6b1a447-382a-5a4f-8086-1521103C337F"],"TypeOfChange":"1","Version":"1.38.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1df98b3d","SWKey":"igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca93656a5","SWKey":"kmod-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec805649d9","SWKey":"kmod-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecdb806fec","SWKey":"i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Drivers for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36","SWKey":"hp-ixgbe-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for SUSE Linux Enterprise Server 16 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb870faaa","SWKey":"ixgbe-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixgbe Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccba99d79","SWKey":"kmod-hp-ixgbe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"HPE Intel Online Firmware Upgrade Utility Linux x86_64 for HPE ProLiant Gen9 and Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL","SWKeyExpectedPath":"firmware:intel_nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_414d6554262e4352b6071552bf","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1521103c337f"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","U36","U39","U45","O43","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp073024.zip","SHA1Sum":"9d1319aedf27f3f22b927a70f020774307f5d518","SHA256Sum":"924fae1ed26c29fa6739b2f0e4a94c608707b61831eb3feb31394b7f541a80e4","SHA512Sum":"c4437d9956b9b7afdc23e63e3249dad35ddb4a62fb6900ce5ab5f4f9be2690ac2e036c8c429a4e4045533cebc7288c40a140906f15f68abd0efbf9d0c7e27a76"}],"ComponentSizeInKB":211,"CompsigList":["cp073024.compsig"],"FileList":["/cp073024.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/index.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/vib20/ixgben/INT_bootbank_ixgben_1.24.1.0-1OEM.900.0.24755229.vib","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/ixgben--6710869395507768838.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.xml"],"Name":"cp073024.zip","SHA1Sum":"9d1319aedf27f3f22b927a70f020774307f5d518","SHA256Sum":"924fae1ed26c29fa6739b2f0e4a94c608707b61831eb3feb31394b7f541a80e4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"ixgben","Version":"1.24.1.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Intel ixgben Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-ixgben:1.24.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.24.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_edf4d4deba224e06adebb19ea0","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U39","U45","U37","U38","U38","02020001","03020101","A59","U77","A66","A66","A72","03020102","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b1c9eaf74c_0HPDB-2.1_amd64.deb","SHA1Sum":"987dc84773633e6a8198993e90efbb239ad98440","SHA256Sum":"321a8842b1f285a5463840787f5fbc0d4da973628d1aae659cb61d70de6540f6","SHA512Sum":"a7dafc34a5c540c4d2e3300cfe2b6a483f0b6165c06abdcd168719b8cf96cd585fb6153bd55da3cb24f28497315d890d7329d6842189b749d117b92eba05bb71"}],"ComponentSizeInKB":4657,"CompsigList":["firmware-hdd-b1c9eaf74c_0HPDB-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/CP071766.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/SSKYBT512EDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071766.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071766.scexe"],"Name":"firmware-hdd-b1c9eaf74c_0HPDB-2.1_amd64.deb","SHA1Sum":"987dc84773633e6a8198993e90efbb239ad98440","SHA256Sum":"321a8842b1f285a5463840787f5fbc0d4da973628d1aae659cb61d70de6540f6","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9cb13839f7f44dbf9998bbb2eb","SupportedDevices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE Eth 10/25Gb 2p Sec Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"26_45_1020-S2A69-63001_Ax_header.pldm.signed.flash","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15b3-101f159003fe","Version":"26.45.1020"}]},"Files":[{"Checksum":[{"Filename":"26_45_1020-S2A69-63001_Ax_header.pldm.fwpkg","SHA1Sum":"578d4a9d11725775a998f33b3b764d6f3dcbdb95","SHA256Sum":"1988a10fa3d0478665264b56ca84f62f8be4240d70afc595650352aab0a080a8","SHA512Sum":"dbf17703239579cb4d3ae70e730dc706eb39e580bd074eda5b9f2cb190aa6363270d49a3e116d875900b19d50a823f3640539bc0fe67714b3594ac73e0648411"}],"ComponentSizeInKB":6994,"CompsigList":[],"FileList":["26_45_1020-S2A69-63001_Ax_header.pldm.signed.flash","26_45_1020-S2A69-63001_Ax_header.pldm.xml","payload.json"],"Name":"26_45_1020-S2A69-63001_Ax_header.pldm.fwpkg","SHA1Sum":"578d4a9d11725775a998f33b3b764d6f3dcbdb95","SHA256Sum":"1988a10fa3d0478665264b56ca84f62f8be4240d70afc595650352aab0a080a8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101f159003fe"],"TypeOfChange":"1","Version":"26.45.1020"}],"InstallationDependency":{},"Name":"Mellanox Firmware Package(FWPKG) for NVIDIA Ethernet 10/25Gb 2-port SFP28 NVMe-oF Crypto Adapter for HPE","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_PA_MCX623105AS-VDAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_66bb24ccc3574c59912c4b9116","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101f159003fe"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","12.0","15.0"]},{"OS":"VMware","Version":["8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","A42","U46","A43","U50","HPE Apollo 2000 Gen10 Plus System","U54","U54","U58","U58","U63","U57","A55","A55","A56","A56","U59","U58","U68","U68","U68","U71","HPE ProLiant DL380m Gen12","U71","U72","U77","U72"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U33_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U33_3.70_08_19_2026.fwpkg","SHA1Sum":"b950624a95f95dc9e5041d4b5ed5a45626e11c8e","SHA256Sum":"2654b20617c68cdbcec670e0482d501449148986502c54c9d6529cbf4ffb686f","SHA512Sum":"1074f5f81091ae8077530e6149f1a9a9618db25a9f6516a10a7901486ac6302f9dee4a5935503d679812deb07103c13f9546afc4cd05ebcb90a9635337c934d4"}],"ComponentSizeInKB":32827,"CompsigList":[],"FileList":["payload.json","U33_3.70_08_19_2026.signed.flash","U33_3.70_08_19_2026.xml"],"Name":"U33_3.70_08_19_2026.fwpkg","SHA1Sum":"b950624a95f95dc9e5041d4b5ed5a45626e11c8e","SHA256Sum":"2654b20617c68cdbcec670e0482d501449148986502c54c9d6529cbf4ffb686f","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant ML110 Gen10 (U33) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_694e32b5161649a1be21ce667a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.0","6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U33"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALFHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058565255","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALFHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058565252","Version":"HPD3"},{"DeviceName":"Kioxia-PM7-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_PM7_KAPM7ALFHPD3.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058565254","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_PM7_KAPM7ALFHPD3.fwpkg","SHA1Sum":"a623f578c663db154b05fc1512812ac47370b13f","SHA256Sum":"85216452bb60f9c10acbdddcad11748f412dbcbd90db437482b591d1deb573b3","SHA512Sum":"b6ee1f30dec529a0b9f1c5b4453c49a19ca804910d32ec7f9fab6062e4ba25d496ba296815d152f8bbf9dd240aef7276b6f354b055082401dd8234c3d415d7f4"}],"ComponentSizeInKB":1621,"CompsigList":[],"FileList":["Kioxia_PM7_KAPM7ALFHPD3.HPb","Kioxia_PM7_KAPM7ALFHPD3.xml","payload.json"],"Name":"Kioxia_PM7_KAPM7ALFHPD3.fwpkg","SHA1Sum":"a623f578c663db154b05fc1512812ac47370b13f","SHA256Sum":"85216452bb60f9c10acbdddcad11748f412dbcbd90db437482b591d1deb573b3","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-305058565255","562340a5-304f-3330-3834-305058565252","562340a5-304f-3730-3638-305058565254"],"TypeOfChange":"2","Version":"HPD3"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO001600PXVRU, VO003840PXVRR and VO007680PXVRT","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600PXVRU","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840PXVRR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680PXVRT","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cfb3c1b576564b7fafa4c9bdcc","SupportedDevices":["562340a5-304f-3730-3638-305058565254","562340a5-304f-3330-3834-305058565252","4d2340a5-304f-3130-3630-305058565255"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e320db791d-MPK78H5Q-6.1.x86_64.rpm","SHA1Sum":"dba0b59c9a99ba00af0a63b0796a04f0b4707d1b","SHA256Sum":"6f0f7ddbf954db11bfac41e02bda371373371c79711631462591ac9ec6bbe591","SHA512Sum":"796af13fde2ba57587090aec50580653c5ce8a5f1a6c000cbfc04c0a6e837998b063fc119ad4277fc1ad7463f789908bcc5e9acfa4a51dee731f4dc9e4e38361"}],"ComponentSizeInKB":9663,"CompsigList":["firmware-hdd-e320db791d-MPK78H5Q-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/CP068912.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/MPK78H5Q.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e320db791d-MPK78H5Q-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068912.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068912.scexe"],"Name":"firmware-hdd-e320db791d-MPK78H5Q-6.1.x86_64.rpm","SHA1Sum":"dba0b59c9a99ba00af0a63b0796a04f0b4707d1b","SHA256Sum":"6f0f7ddbf954db11bfac41e02bda371373371c79711631462591ac9ec6bbe591","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Linux (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1070be9bbbed4c4086fa6ad674","SupportedDevices":["4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3830-3048d90154e8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB001000GWJAN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-3047574a414e","Version":"HPG1"},{"DeviceName":"MB002000GWFWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757465741","Version":"HPG1"},{"DeviceName":"MB004000GWFWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TATCATSATAG1.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757465742","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d39e7a7e75-HPG1-15.1.x86_64.rpm","SHA1Sum":"b1bb096ab0886b6fe4af19db55bd1a4a71df5e9c","SHA256Sum":"1c5da7435c7e896f1d27219528d9f9ed4f79ec18a72b135baa7026a315ddb3eb","SHA512Sum":"dab1642a00e2f719ae9419291930e780062d1cb691e24254a10dac4c801337dfb65ef81a2bf5a5378b8538aad5c5c4f5bf486c8c11509e0d1d2b21544ba027db"}],"ComponentSizeInKB":5377,"CompsigList":["firmware-hdd-d39e7a7e75-HPG1-15.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/CP068855.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/TATCATSATAG1.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d39e7a7e75-HPG1-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068855.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068855.scexe"],"Name":"firmware-hdd-d39e7a7e75-HPG1-15.1.x86_64.rpm","SHA1Sum":"b1bb096ab0886b6fe4af19db55bd1a4a71df5e9c","SHA256Sum":"1c5da7435c7e896f1d27219528d9f9ed4f79ec18a72b135baa7026a315ddb3eb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3130-3030-3047574a414e","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3430-3030-304757465742"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB001000GWJAN, MB002000GWFWA and MB004000GWFWB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB001000GWJAN","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWFWA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB004000GWFWB","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7123f9b68d74ac2a66fa30f9b","SupportedDevices":["4d2340a5-3042-3430-3030-304757465742","4d2340a5-3042-3230-3030-304757465741","4d2340a5-3042-3130-3030-3047574a414e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-42aff4675b-HPD5-2.1.x86_64.rpm","SHA1Sum":"df129b058635f8a851fa802deda698e30d2705e0","SHA256Sum":"ea1001cc06988b542ee1892e0e53c8c93aa0cbe2de3ec0cf74a757f5adf33581","SHA512Sum":"a214cefdcfa383e1463c7fa660d8ec83a60a54c77258ed62ef6aad809f2c531ae2558d191682fb8624f96c5ab5f7e5ca56a85563d4ae710a60227aa5f6bff2ec"}],"ComponentSizeInKB":5747,"CompsigList":["firmware-hdd-42aff4675b-HPD5-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/CP068923.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/KAPM6ALSHPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068923.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068923.scexe"],"Name":"firmware-hdd-42aff4675b-HPD5-2.1.x86_64.rpm","SHA1Sum":"df129b058635f8a851fa802deda698e30d2705e0","SHA256Sum":"ea1001cc06988b542ee1892e0e53c8c93aa0cbe2de3ec0cf74a757f5adf33581","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1acfb6855d7e460f8e0c563239","SupportedDevices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3531-3330-305058444256","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907bf452-0f78-4311-ab8a-4fc6f1c1688e","Devices":{"Device":[{"DeviceName":"HPE D3600 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18da6dd779","Version":"5.04"},{"DeviceName":"HPE D3700 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd186af467e1","Version":"5.04"},{"DeviceName":"HPE D3610 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18142a1148","Version":"5.04"},{"DeviceName":"HPE D3710 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"Reveille-Release-5.04-build-000.bin","InstallDurationSec":900,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18c6ad21a7","Version":"5.04"}]},"Files":[{"Checksum":[{"Filename":"firmware-d3000-5.04-18.1.x86_64.rpm","SHA1Sum":"1a789003460c57dea29adeb0b6ee1c602dcf1109","SHA256Sum":"6818468e920bd0056937fcb66be519a4802f4825d8d9f77c27daff69a649f18e","SHA512Sum":"fa190815851db15f9132f926420f43508642c850930043afd7f865f44cac8fb8bffa3fdba24b85f7dbd75a48706d2e5917c8533d9c0fc0349159497fe25e2877"}],"ComponentSizeInKB":3605,"CompsigList":["firmware-d3000-5.04-18.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/CP072210.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/Reveille-Release-5.04-build-000.bin","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d3000-5.04-18.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072210.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072210.scexe"],"Name":"firmware-d3000-5.04-18.1.x86_64.rpm","SHA1Sum":"1a789003460c57dea29adeb0b6ee1c602dcf1109","SHA256Sum":"6818468e920bd0056937fcb66be519a4802f4825d8d9f77c27daff69a649f18e","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"TypeOfChange":"1","Version":"5.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D3600/D3700/D3610/D3710 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D3600","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3700","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3610","SWKeyExpectedPath":"firmware:sd:disk_enclosure"},{"Name":"D3710","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ce30312f59f4c64a37da66b32","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18da6dd779","b99dfb74-f0bc-464f-b418-cd18142a1148","b99dfb74-f0bc-464f-b418-cd186af467e1","b99dfb74-f0bc-464f-b418-cd18c6ad21a7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","9.0","15.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U41_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U41_3.70_08_19_2026.fwpkg","SHA1Sum":"72250e9b88763de971c2d39dfed48e8293ddf2d6","SHA256Sum":"8da8a273f47ac79437e0e160442c92a0d2c543a52da9efa63a8334060215993d","SHA512Sum":"aae675f35a31aaa0580d5f55dae357511afeb953a6605aa9e2d4557ec7c88d5f62ffacc75ee1607c5f1c81beda089d7e4865d257cb1336b90b25cf50f2e72d41"}],"ComponentSizeInKB":32827,"CompsigList":[],"FileList":["payload.json","U41_3.70_08_19_2026.signed.flash","U41_3.70_08_19_2026.xml"],"Name":"U41_3.70_08_19_2026.fwpkg","SHA1Sum":"72250e9b88763de971c2d39dfed48e8293ddf2d6","SHA256Sum":"8da8a273f47ac79437e0e160442c92a0d2c543a52da9efa63a8334060215993d","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant ML350 Gen10 (U41) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f5b70556e0f7440d9cc27597fe","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U41"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000253","Version":"v2.70 (08/20/2026)"},{"DeviceName":"System BIOS - U64","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U64_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000254","Version":"v2.70 (08/20/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073270.exe","SHA1Sum":"8964fd930dfcc10955d1931c2ec01dae65d33839","SHA256Sum":"34f6c64deaca0bb610c906d7cbf29fcb4bc27df5390c8edcedff6796404916a5","SHA512Sum":"36b760c7683c40599e6f22d42da6d6e6a8273555660c3676dbdbca8ec9a07ce317ee8ddd4e2f6111e04cf3646a2b5f463721b92336eced6afd6eb2cddd28526b"}],"ComponentSizeInKB":17042,"CompsigList":["cp073270.compsig"],"FileList":["cp073270.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U64_2.70_08_20_2026.signed.flash"],"Name":"cp073270.exe","SHA1Sum":"8964fd930dfcc10955d1931c2ec01dae65d33839","SHA256Sum":"34f6c64deaca0bb610c906d7cbf29fcb4bc27df5390c8edcedff6796404916a5","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000253","00000000-0000-0000-0000-000000000254"],"TypeOfChange":"1","Version":"2.70_08-20-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant MicroServer Gen10 Plus v2 (U64) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U64","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_abd22380f94f41839350d42b69","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U64"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWRTD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL8CBA0HPD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57525444","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8b26d1ef02-HPD3-2.1.x86_64.rpm","SHA1Sum":"51127325151ab9f28c8541e3ef594a5511ce2df6","SHA256Sum":"b47f97f6775a5383bb7db693179443dd54af8b5afd50687046488fbde6bf9a47","SHA512Sum":"359102a98ea1639a43a6be8995202711765ad6da1933053e1f819f74c36d2ed916a41aefdfc361454512465194b7e065b53b65b780e0c255de3ff012744fe6e8"}],"ComponentSizeInKB":6157,"CompsigList":["firmware-hdd-8b26d1ef02-HPD3-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/CP073254.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/WVL8CBA0HPD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8b26d1ef02-HPD3-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073254.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073254.scexe"],"Name":"firmware-hdd-8b26d1ef02-HPD3-2.1.x86_64.rpm","SHA1Sum":"51127325151ab9f28c8541e3ef594a5511ce2df6","SHA256Sum":"b47f97f6775a5383bb7db693179443dd54af8b5afd50687046488fbde6bf9a47","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57525444"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWRTD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWRTD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bf2cdef02ee0408f98a94e8936","SupportedDevices":["4d2340a5-3042-3830-3030-304a57525444"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM238.1.169.0_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41599","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM238.1.169.0_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41599","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM238.1.169.0_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41599","Version":"238.1.169.0"}]},"Files":[{"Checksum":[{"Filename":"BCM238.1.169.0_BCM957504-P425H.fwpkg","SHA1Sum":"d269b3c994dc48981fde1634b72a0ce48322fa7e","SHA256Sum":"1e7c8e5098cc80349b5efe9e74273a5f787ac1b20d786fa67e1738947aa9cde4","SHA512Sum":"69e919fe172f08a9d8dd58c14fbc28e0bbf6b5716a831811a7d6e898cf76090d17e36c42edd15fa56a7afd4f1c8c64f1f5503c715397a4a4a5c40be69becccc9"}],"ComponentSizeInKB":2920,"CompsigList":[],"FileList":["BCM238.1.169.0_BCM957504-P425H.HPb","BCM238.1.169.0_BCM957504-P425H.xml","payload.json"],"Name":"BCM238.1.169.0_BCM957504-P425H.fwpkg","SHA1Sum":"d269b3c994dc48981fde1634b72a0ce48322fa7e","SHA256Sum":"1e7c8e5098cc80349b5efe9e74273a5f787ac1b20d786fa67e1738947aa9cde4","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180414e41599"],"TypeOfChange":"1","Version":"238.1.169.0"}],"InstallationDependency":{},"MinimumActiveVersion":"235.1.220.0","Name":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE_57504_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b0acd3902e4d46d98ca2ff8d95","SupportedDevices":["a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-175114e41599"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","H10","H10","H10","U46"],"Type":"ComboFirmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8d68452816-HPD9-2.1.x86_64.rpm","SHA1Sum":"9eb0fae9635cd26524bd9306f3984ee5126580d7","SHA256Sum":"2cd03f3386457becf4703bee44256b4bc67ec6f6c78978ea485729d1c5cfa3bd","SHA512Sum":"5c2ec6da98749c340f3924e6687b9a85630c68657d3bd17bbb93ba691c7882dec28e0d8220fe5970bfd66772c82d16fae620a71b502508ccf019e40380b06138"}],"ComponentSizeInKB":5012,"CompsigList":["firmware-hdd-8d68452816-HPD9-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/CP068860.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/TA14SXn0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068860.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068860.scexe"],"Name":"firmware-hdd-8d68452816-HPD9-2.1.x86_64.rpm","SHA1Sum":"9eb0fae9635cd26524bd9306f3984ee5126580d7","SHA256Sum":"2cd03f3386457becf4703bee44256b4bc67ec6f6c78978ea485729d1c5cfa3bd","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8973e5e1313f4302babcdb7c39","SupportedDevices":["452340a5-3048-3030-3330-304a5748504c","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3930-304a57485050"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H10","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H10_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-h10-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"f6bb1dca345d15e9467bc6e4040f1c63b264cc22","SHA256Sum":"2d7920943f39d690758030fd8bac2adc19f9dd508ba21bc5243b887126165688","SHA512Sum":"1571f0fcf6736900a715419f3adc73581044418c1bf8aa970470c98ca3dba9bfaffc55b4d13c1cb51bfc993f46980a3e3013cc5653af2b3a9e220693e39ebb84"}],"ComponentSizeInKB":33226,"CompsigList":["firmware-system-h10-2.70_2026_08_19-1.1.x86_64_part1.compsig","firmware-system-h10-2.70_2026_08_19-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.70_2026_08_19-1.1/CP073120.xml","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.70_2026_08_19-1.1/H10_2.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-h10-2.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073120.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073120.scexe"],"Name":"firmware-system-h10-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"f6bb1dca345d15e9467bc6e4040f1c63b264cc22","SHA256Sum":"2d7920943f39d690758030fd8bac2adc19f9dd508ba21bc5243b887126165688","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023a"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H10","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d649910b496e46dfb0ffc6dd73","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","15.0","8.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["HPE Edgeline EL8000t Converged Edge System","H10","FTP","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e4c","Version":"HPD6"},{"DeviceName":"EG002400JWJNN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEE0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-852266afdf_0HPD6-2.1_amd64.deb","SHA1Sum":"0e7a0df2284e331c6ff6520a9ca5a97b98769415","SHA256Sum":"bb65e144aed79b86d9f60f6679357f402c044e22f821105e264c838d1eb684f5","SHA512Sum":"334863ad46db3fbf52e23bb8a7a4b6e29d7f7f5aba88a417344b6e1bbd4aa10152a83fb3022b04cff6dab9122db047d4e8b287fbdae325ff3581ba2bc6a428e4"}],"ComponentSizeInKB":3472,"CompsigList":["firmware-hdd-852266afdf_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/CP071765.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/TA15SEE0HPD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071765.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-852266afdf-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071765.scexe"],"Name":"firmware-hdd-852266afdf_0HPD6-2.1_amd64.deb","SHA1Sum":"0e7a0df2284e331c6ff6520a9ca5a97b98769415","SHA256Sum":"bb65e144aed79b86d9f60f6679357f402c044e22f821105e264c838d1eb684f5","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e4c","452340a5-3047-3230-3430-304a574a4e4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EG001800JWJNL and EG002400JWJNN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b6f4fc0cfd7b45808926f3cdb3","SupportedDevices":["452340a5-3047-3230-3430-304a574a4e4e","452340a5-3047-3130-3830-304a574a4e4c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069521.exe","SHA1Sum":"0173147547c8c3cbd37a36d87cb27ca1315f72d7","SHA256Sum":"006c412c6ed4ed7a9bf431c360d2216600183725e376c1734a4213bb2717c108","SHA512Sum":"1161b0af14bd3abd1762bba145ecd770342e5e115fcc07d95678a20be3a72e59122067dadd79ba897103047d04f42daf9e06db09b6825ff8a04ab654b82e5006"}],"ComponentSizeInKB":1054,"CompsigList":["cp069521.compsig"],"FileList":["cp069521.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069521.exe","SHA1Sum":"0173147547c8c3cbd37a36d87cb27ca1315f72d7","SHA256Sum":"006c412c6ed4ed7a9bf431c360d2216600183725e376c1734a4213bb2717c108","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.1.24.0"}],"InstallationDependency":{},"Name":"HPE Intel E1R Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f339b773d97449db8bc0d1ac2b","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","H08","H08","H10","H10","H10","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400JWDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57444b50","Version":"HPD3"},{"DeviceName":"EO000800JWDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57444b51","Version":"HPD3"},{"DeviceName":"EO001600JWDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57444b52","Version":"HPD3"},{"DeviceName":"MO000400JWDKU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57444b55","Version":"HPD3"},{"DeviceName":"MO000800JWDKV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57444b56","Version":"HPD3"},{"DeviceName":"MO001600JWDLA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57444c41","Version":"HPD3"},{"DeviceName":"MO003200JWDLB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"BCHPC17M.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57444c42","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-5dcf26fa42-HPD3-5.1.x86_64.rpm","SHA1Sum":"caed8742ed3070f3d8d75c5d401b41d2ffb7aa32","SHA256Sum":"395804142dcfc9ca7c0101a7d61f307ab725d632ac6417a3eb655e1ed873963a","SHA512Sum":"3eb943f9a5a448ec09904546b88bb7ae0bdb66e0d104c7704c49fe912474ab6076c855e28c675f9bc399625b50fbf09e4ca35a9382a864d7637126a661cb4e45"}],"ComponentSizeInKB":5738,"CompsigList":["firmware-hdd-5dcf26fa42-HPD3-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/BCHPC17M.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/CP068852.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-5dcf26fa42-HPD3-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068852.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068852.scexe"],"Name":"firmware-hdd-5dcf26fa42-HPD3-5.1.x86_64.rpm","SHA1Sum":"caed8742ed3070f3d8d75c5d401b41d2ffb7aa32","SHA256Sum":"395804142dcfc9ca7c0101a7d61f307ab725d632ac6417a3eb655e1ed873963a","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-304a57444b50","452340a5-304f-3030-3830-304a57444b51","452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3030-3430-304a57444b55","4d2340a5-304f-3030-3830-304a57444b56","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - EO000400JWDKP, EO000800JWDKQ, EO001600JWDKR, MO000400JWDKU, MO000800JWDKV, MO001600JWDLA and MO003200JWDLB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400JWDKP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWDKQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWDKR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWDKU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWDKV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWDLA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWDLB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7d25ddccca094465af5c279763","SupportedDevices":["452340a5-304f-3130-3630-304a57444b52","4d2340a5-304f-3130-3630-304a57444c41","4d2340a5-304f-3330-3230-304a57444c42","452340a5-304f-3030-3430-304a57444b50","4d2340a5-304f-3030-3430-304a57444b55","452340a5-304f-3030-3830-304a57444b51","4d2340a5-304f-3030-3830-304a57444b56"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.21"}]},"Files":[{"Checksum":[{"Filename":"CP071317.zip","SHA1Sum":"faecc96d0bc2548fbe6f0554675d652f8adfb916","SHA256Sum":"ca5fa5049033b027104c66f47806de942e0f1ac50af52424d096ec08ba9c2fd4","SHA512Sum":"4441881f2e077e246de9daf4c732bd9e1f79515b61d3533d8d16c37f40d34cf0d39597812e918fb9dba90cb51eea1485ec9b1d6e4267fc104aa9c04f2c6172ff"}],"ComponentSizeInKB":5624,"CompsigList":["CP071317.compsig"],"FileList":["/CP071317_BUILD_3.data","/CP071317.vmexe","/CP071317.vmexe64","/CP071317.vmfile","/CP071317_VMw.zip","/CP071317.xml","/payload.json","/CP071317_VMw.zip/index.xml","/CP071317_VMw.zip/vendor-index.xml","/CP071317_VMw.zip/metadata.zip","/CP071317_VMw.zip/vib20/CP071317/HPE_bootbank_CP071317_2026.06.01.3-8.0.0.20613240.vib","/CP071317_VMw.zip/metadata.zip/vendor-index.xml","/CP071317_VMw.zip/metadata.zip/vmware.xml","/CP071317_VMw.zip/metadata.zip/vibs/CP071317-1236188951939555293.xml","/CP071317_VMw.zip/metadata.zip/bulletins/Smart-Component-CP071317_2026.06.01.3-8.0.0.20613240.xml"],"Name":"CP071317.zip","SHA1Sum":"faecc96d0bc2548fbe6f0554675d652f8adfb916","SHA256Sum":"ca5fa5049033b027104c66f47806de942e0f1ac50af52424d096ec08ba9c2fd4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01","VibList":[{"Name":"CP071317","Version":"2026.06.01.3-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for VMware vSphere  8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2995636f8942413eac7ae898cb","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-befd42bd64_0HPG3-2.1_amd64.deb","SHA1Sum":"c627aae360a53ddf622e38a26585991cc4e826b0","SHA256Sum":"1cc9e37ae9a4d9d931ad167bd169f2a8744aa230ba1c4b233c583d5dd934b197","SHA512Sum":"1bb91b3b236493f7bf667c3d06f7eaad269c60fb5827aafe4579f8f669cd5b0543c796282bb52b2d978c5f729d45e6229d6d6334d6efc10bb04e02e5da99f82e"}],"ComponentSizeInKB":7486,"CompsigList":["firmware-hdd-befd42bd64_0HPG3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/CP071811.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/K511HPG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071811.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-befd42bd64-HPG3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071811.scexe"],"Name":"firmware-hdd-befd42bd64_0HPG3-2.1_amd64.deb","SHA1Sum":"c627aae360a53ddf622e38a26585991cc4e826b0","SHA256Sum":"1cc9e37ae9a4d9d931ad167bd169f2a8744aa230ba1c4b233c583d5dd934b197","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_326bafcd936d4f7aaf50e7de12","SupportedDevices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//HPE_X710DA2_OCP3_9p57_CFGID7p2_K97342_80010346.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.4002.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//HPE_X710DA2_9p57_CFGID7p2_K97470_80010350.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.4002.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.4002.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.4002.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.4002.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.4002.0"}]},"Files":[{"Checksum":[{"Filename":"cp072309.exe","SHA1Sum":"ac91e058961e178db99457b9029c0efbd8d94c00","SHA256Sum":"1b5a17497a3a21887d147a47faf47392cffccfe20c99c32c6229f9b8d50ec6ff","SHA512Sum":"ae98a41da82b621e44bac71ae1acc0aa98f9bc726f3c3a06c9eb6ba6c2b8d8991da8f1a6979b299bcf2b7c5ed610c48d9880c1f32bb2f20632528beea7ed1809"}],"ComponentSizeInKB":7062,"CompsigList":["cp072309.compsig"],"FileList":["cp072309.xml","cpqsetup.exe","FW/","FW/BootIMG_ISA.FLB","FW/hpesinglenvmconfig.txt","FW/HPE_1G_Adapter_VPD_MAP_ISA.txt","FW/HPE_i350T4_K68277_8000123F.txt","FW/HPE_i350T4_OCP_K53978_80001234.txt","FW/HPE_I350_2p_Cu_NCSI_1.61_8000119C.txt","FW/HPE_I350_4p_Cu_NCSI_1.61_8000119D.txt","FW/HPE_X710DA2_9p57_CFGID7p2_K97470_80010350.bin","FW/HPE_X710DA2_OCP3_9p57_CFGID7p2_K97342_80010346.bin","FW/HPE_X710_DA_OCP3_EEPROM_MAP.txt","FW/hpnvmupdate.cfg","HPNVMUpdate.exe","install.bat","iqvsw64e.cat","iqvsw64e.inf","iqvsw64e.sys","ja/","ja/NICOFUT.chm","NICOFUT.chm","nvmupdate.bat","nvmupdatewin64e.dll","ofvpdfixW64e.exe","OnlineFWUpgrade.dll","payload.json","rfendfixW64e.exe","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp072309.exe","SHA1Sum":"ac91e058961e178db99457b9029c0efbd8d94c00","SHA256Sum":"1b5a17497a3a21887d147a47faf47392cffccfe20c99c32c6229f9b8d50ec6ff","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"5.4.8.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca94d0369","SWKey":"e1r63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5963c8f7","SWKey":"e1r64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec090ca3ac","SWKey":"e1r65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec08dc7810","SWKey":"ixn63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecaf3c08f1","SWKey":"ixt63x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3804451b","SWKey":"ixt64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44051c","SWKey":"ixn64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2bead763","SWKey":"ixt65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn/ixt Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8a51872f","SWKey":"ixn65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.16.202.0"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca9730c7d","SWKey":"i40ea63.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc261833","SWKey":"i40ea64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3bb214b3","SWKey":"i40ea65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec45933bde","SWKey":"ixs64x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2cbf818e","SWKey":"ixs65x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec507d6c9c","SWKey":"i40eb65.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec77fc8d87","SWKey":"i40eb64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel E1R Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312","SWKey":"e1r68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecc6f71532","SWKey":"i40ea68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec24ae2520","SWKey":"i40eb68.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixn Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b","SWKey":"ixn68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecee44d472","SWKey":"ixs68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixt Driver for Windows Server 2019 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.17600"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5c8e5025","SWKey":"ixt68x64.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.1.197.0"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel e1r Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec743e0890","SWKey":"e1r.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40ea Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a","SWKey":"i40ea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40eb Driver for Windows Server 2025 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d","SWKey":"i40eb.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel icea Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec340d3099","SWKey":"icea.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel iavf Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b","SWKey":"iavf.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel ixs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b","SWKey":"ixs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel vxs Driver for Windows Server 2022 must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"10.0.20317"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727","SWKey":"vxs.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"Intel Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"HPNVMUpdate.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e6c6e73ba9ce43278873c850b4","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["02020001","03020101","A59","A42","U46","U46","A43","A47","A48","A46","U47","U48","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","A42","U46","U77","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069551.exe","SHA1Sum":"0f6a563758edbd7548fc32917e79375c18fcddaf","SHA256Sum":"2bafd7d88d662165a8e744dc76355866aa66805ca28e367e8c97e419f0887fdb","SHA512Sum":"a855b6484ff605e570fd60dc41020eb4cb4aca4f2b2aba1fdc0ee013025e7dab55bd08b7eed9a847d167f5aab0333074cf0260b46397000da111bcac9061a5bd"}],"ComponentSizeInKB":1013,"CompsigList":["cp069551.compsig"],"FileList":["cp069551.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs.cat","ixs.inf","ixs.sys","ixsmsg.dll","nicdrvr.dll"],"Name":"cp069551.exe","SHA1Sum":"0f6a563758edbd7548fc32917e79375c18fcddaf","SHA256Sum":"2bafd7d88d662165a8e744dc76355866aa66805ca28e367e8c97e419f0887fdb","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"TypeOfChange":"1","Version":"4.1.254.0"}],"InstallationDependency":{},"Name":"HPE Intel ixs Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"ixs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\ixs.inf_amd64_166a1f78fe537c55"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b70a0115b54549caa0ab62a22d","SupportedDevices":["a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"cp068656.exe","SHA1Sum":"b8b3bd831761906cd1ebb330c47d4948f56331d2","SHA256Sum":"0e778a085ea22546d937519806556fa9b9ecefae2eaa48d8c924e428aada2021","SHA512Sum":"b2c276a44228fbe0a6e90799dab313ef0580ec566da670b2d09e67661ce58dfb615454fc4346f36b521ada4875dd1844b51381885a24780553f8abd8d5f9e936"}],"ComponentSizeInKB":3935,"CompsigList":["cp068656.compsig"],"FileList":["cp068656.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SKESTNDB.rel"],"Name":"cp068656.exe","SHA1Sum":"b8b3bd831761906cd1ebb330c47d4948f56331d2","SHA256Sum":"0e778a085ea22546d937519806556fa9b9ecefae2eaa48d8c924e428aada2021","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_06611b50fde44566a65773be61","SupportedDevices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e4f147cdd2-HPG5-1.1.x86_64.rpm","SHA1Sum":"3e2aa09c4314f9ce7635fe9ecd4c43ca098233bd","SHA256Sum":"89a14560da4c211c0a8e41477edfca72d3771f958952ed651dbc8053911bd293","SHA512Sum":"c54dfe6a30d2a6a8efffd5b8f115ddee95dec84d6f01c87886cb3e7d47a085f5c6a019d2f64d2bad96973227a8c2bcdd5edd580187ce098d944a944f3aafa20c"}],"ComponentSizeInKB":5716,"CompsigList":["firmware-hdd-e4f147cdd2-HPG5-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/CP068771.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/TAMG08acHPG5.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068771.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068771.scexe"],"Name":"firmware-hdd-e4f147cdd2-HPG5-1.1.x86_64.rpm","SHA1Sum":"3e2aa09c4314f9ce7635fe9ecd4c43ca098233bd","SHA256Sum":"89a14560da4c211c0a8e41477edfca72d3771f958952ed651dbc8053911bd293","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB016000GWXKK Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6e6d29bd80284557a538b51f01","SupportedDevices":["4d2340a5-3042-3631-3030-304757584b4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H08","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H08_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000221","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073190.exe","SHA1Sum":"04426ec7321f9c4362fdace787d3324fe9b86ab2","SHA256Sum":"0ab0c8ccd92074bababaf61c29f8a596f71373940e2e105a51cb5af623416608","SHA512Sum":"e03094cadfc9cb3cc1d1062776a8860cd087ec14ad99bf970a6810656c409d531047ec35a21cebe941fa681165428c08a1bcdba650aee7a2515003aa149b16dc"}],"ComponentSizeInKB":11158,"CompsigList":["cp073190.compsig"],"FileList":["cp073190.xml","cpqsetup.exe","H08_3.70_08_19_2026.signed.flash","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp073190.exe","SHA1Sum":"04426ec7321f9c4362fdace787d3324fe9b86ab2","SHA256Sum":"0ab0c8ccd92074bababaf61c29f8a596f71373940e2e105a51cb5af623416608","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant e910/e910t Server Blade (H08)","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H08","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_821b27b13d444da296fb2fc6fb","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0","10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072296.exe","SHA1Sum":"b72c5083e1512f9d0efdd40e9425ab00572b79c4","SHA256Sum":"14af75a627c6c328ae0723c0d78742fc63e96f5f58ebc2d38b6196276ea5ed97","SHA512Sum":"0bea4de19c456c87534244bdd760a40d9809e26ac61cd099047bf49af4e8ef4270e705e6492bac212b4ecdafdeb2b6587f937a0bb51d05fccbfed8b4184ce3f8"}],"ComponentSizeInKB":622,"CompsigList":["cp072296.compsig"],"FileList":["cp072296.xml","cpqsetup.exe","installer.dll","pnp/","pnp/IceLakeX.cat","pnp/IceLakeXSystem.inf","pnp/lewisburg.cat","pnp/LewisburgSystem.inf","pnp/Server_Common.cat","pnp/Server_CommonSystem.inf","pnp/Server_CommonSystemNorthpeak.inf","pnp/Skylake-E.cat","pnp/Skylake-ESystem.inf"],"Name":"cp072296.exe","SHA1Sum":"b72c5083e1512f9d0efdd40e9425ab00572b79c4","SHA256Sum":"14af75a627c6c328ae0723c0d78742fc63e96f5f58ebc2d38b6196276ea5ed97","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"10.1.19879.8585"}],"InstallationDependency":{},"Name":"Identifiers for Intel Xeon Scalable Processors (Third Generation) for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_de4203a2dcc2446ea1d693aca4","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","U56","H10","H10","H10","U50"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071992.exe","SHA1Sum":"55ea60534d445f17a725ee3a892547d8028d2fd8","SHA256Sum":"4a7d018fcf2eb4ae7d34cf45bcb8c8caf93545bb657937f4310f3ce001661838","SHA512Sum":"0d5a0d7b328ef6b4deeb7f45cb1748eb5a77419ceea3296e3c481e2d39ce867b6496eeaea5d9ac45c1534240d4dba68079d7b2e1eafa41eda94509a5532ec85f"}],"ComponentSizeInKB":705,"CompsigList":["cp071992.compsig"],"FileList":["cp071992.xml","cpqsetup.exe","installer.dll","pnp/","pnp/AMDCCP.cat","pnp/AMDCCP.inf","pnp/amddrtm.cat","pnp/amddrtm.dll","pnp/amddrtm.inf","pnp/AMDPCIDev.cat","pnp/AMDPCIDev.inf","pnp/amdpsp.cat","pnp/amdpsp.inf","pnp/SMBUSamd.cat","pnp/SMBUSamd.inf"],"Name":"cp071992.exe","SHA1Sum":"55ea60534d445f17a725ee3a892547d8028d2fd8","SHA256Sum":"4a7d018fcf2eb4ae7d34cf45bcb8c8caf93545bb657937f4310f3ce001661838","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"8.3.14.329"}],"InstallationDependency":{},"Name":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows Server 2022 and 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a9fea24f197844038515593beb","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","A40","A43","A41","A46","A47","A42","A43","A43","A42","A48"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE90X0_SED-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE90X0_SED_KPE9010SHPK2.HPb","InstallDurationSec":180,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3936-305959585052","Version":"HPK2"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PE90X0_SED_KPE9010SHPK2.fwpkg","SHA1Sum":"dc7466f6b7ee57ffc5b178e3e9877efe912ec83f","SHA256Sum":"0ee879e26b98d681ddb9d0e434be54a7444b56c3524440517560cfd008ccdc79","SHA512Sum":"07906367ba6ce2e59a17c61a1a1698bbf5769419fd3e0e8d5c8eb28ce0e03167c590f1d56348be6966557f3f9e72143d2beaae618c9410bff725c01b0c06ae63"}],"ComponentSizeInKB":1944,"CompsigList":[],"FileList":["payload.json","SKHynix_PE90X0_SED_KPE9010SHPK2.HPb","SKHynix_PE90X0_SED_KPE9010SHPK2.xml"],"Name":"SKHynix_PE90X0_SED_KPE9010SHPK2.fwpkg","SHA1Sum":"dc7466f6b7ee57ffc5b178e3e9877efe912ec83f","SHA256Sum":"0ee879e26b98d681ddb9d0e434be54a7444b56c3524440517560cfd008ccdc79","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3052-3030-3936-305959585052"],"TypeOfChange":"1","Version":"HPK2"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  VR000960YYXPR","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":180,"RebootRequired":"no","SWKeys":[{"Name":"VR000960YYXPR","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5dba513ef7be49eebd9375bee8","SupportedDevices":["562340a5-3052-3030-3936-305959585052"],"SupportedOperatingSystems":[],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services (SPS) E3 Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"DL20ML30Gen10SPS_05.01.05.216.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-a3601590028d","Version":"05.01.05.216"}]},"Files":[{"Checksum":[{"Filename":"DL20ML30Gen10SPS_05.01.05.216.fwpkg","SHA1Sum":"84596e794f602d33b5b48163b5c1fb48745af2a2","SHA256Sum":"388f38a55a4549e97d75966f358d487ae88f05fe3f6f5e7deedbe5f13e0d4f6a","SHA512Sum":"753a8af23b3acd7d863fdade2558be30429d89ce567ec86d2deb049caee04a16835d7985e1d65018831ad43374b1c6eeff29470ff7910fb901afb5905edd7b37"}],"ComponentSizeInKB":1963,"CompsigList":[],"FileList":["DL20ML30Gen10SPS_05.01.05.216.signed.bin","DL20ML30Gen10SPS_05.01.05.216.xml","payload.json"],"Name":"DL20ML30Gen10SPS_05.01.05.216.fwpkg","SHA1Sum":"84596e794f602d33b5b48163b5c1fb48745af2a2","SHA256Sum":"388f38a55a4549e97d75966f358d487ae88f05fe3f6f5e7deedbe5f13e0d4f6a","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-a3601590028d"],"TypeOfChange":"1","Version":"05.01.05.216"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware  for HPE Gen10 Servers","PackageFormat":"FWPKG","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d464730ba8854d9b8f7c34abae","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U43","U44"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MO000400JWUFT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57554654","Version":"HPD4"},{"DeviceName":"MO000800JWUFU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57554655","Version":"HPD4"},{"DeviceName":"MO001600JWUFV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57554656","Version":"HPD4"},{"DeviceName":"MO003200JWUGA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57554741","Version":"HPD4"},{"DeviceName":"MO006400JWUGB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57554742","Version":"HPD4"},{"DeviceName":"EO000400JWUGC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57554743","Version":"HPD4"},{"DeviceName":"EO000800JWUGD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57554744","Version":"HPD4"},{"DeviceName":"EO001600JWUGE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WBCPssssASFD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57554745","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070985.zip","SHA1Sum":"51c1431e0aa81b8e75e923ac142d5925b007b39f","SHA256Sum":"f480a5fcc807bdd0fb47a28cf72b85b85634e4bc7ba52e640d849279d8c63872","SHA512Sum":"04e83c185fa096ffd3faee979b85e4c73547c3981eb1c095656dd8cdf0562d355c054557c8520fa2fa4cd3fa85d8afec541114ee6d217974170d5c5d67650e44"}],"ComponentSizeInKB":18408,"CompsigList":["CP070985.compsig"],"FileList":["/CP070985_BUILD_2.data","/CP070985.vmexe64","/CP070985.vmfile","/CP070985_VMw.zip","/CP070985.xml","/payload.json","/CP070985_VMw.zip/index.xml","/CP070985_VMw.zip/vendor-index.xml","/CP070985_VMw.zip/metadata.zip","/CP070985_VMw.zip/vib20/CP070985/HPE_bootbank_CP070985_HPD4.2-8.0.0.20613240.vib","/CP070985_VMw.zip/metadata.zip/vendor-index.xml","/CP070985_VMw.zip/metadata.zip/vmware.xml","/CP070985_VMw.zip/metadata.zip/vibs/CP070985--4096589684061340777.xml","/CP070985_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070985_HPD4.2-8.0.0.20613240.xml"],"Name":"CP070985.zip","SHA1Sum":"51c1431e0aa81b8e75e923ac142d5925b007b39f","SHA256Sum":"f480a5fcc807bdd0fb47a28cf72b85b85634e4bc7ba52e640d849279d8c63872","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304f-3030-3430-304a57554654","4d2340a5-304f-3030-3830-304a57554655","4d2340a5-304f-3130-3630-304a57554656","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3630-3430-304a57554742","452340a5-304f-3030-3430-304a57554743","452340a5-304f-3030-3830-304a57554744","452340a5-304f-3130-3630-304a57554745"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070985","Version":"HPD4.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MO000400JWUFT, MO000800JWUFU, MO001600JWUFV, MO003200JWUGA, MO006400JWUGB, EO000400JWUGC, EO000800JWUGD and EO001600JWUGE  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000400JWUFT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWUFU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWUFV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWUGA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWUGB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWUGC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWUGD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWUGE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c2c06eb8c3ad475c83a108987b","SupportedDevices":["4d2340a5-304f-3630-3430-304a57554742","4d2340a5-304f-3330-3230-304a57554741","4d2340a5-304f-3130-3630-304a57554656","452340a5-304f-3130-3630-304a57554745","4d2340a5-304f-3030-3830-304a57554655","452340a5-304f-3030-3830-304a57554744","4d2340a5-304f-3030-3430-304a57554654","452340a5-304f-3030-3430-304a57554743"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-tg3-3.140b-1.rhel10u1.x86_64.rpm","SHA1Sum":"449d546cab5adb598c5d9391fca3bbe4c056d2b7","SHA256Sum":"eafe7d1a28bfcff40302c4e5a75294db5bb70823194a7f388dbd2325cf1d927a","SHA512Sum":"1fd7764d9d70efe6e0097c6ee01d63b33b19ecf09a70b524845ea9c95ae0ad476a87b05aee1f2e7f1a0e1fb038f00dcc5a5626e2e8582e58c2d6de273d5cccb2"}],"ComponentSizeInKB":163,"CompsigList":["kmod-tg3-3.140b-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/tg3.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/tg3","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/65","./usr/lib/.build-id/65/ae9dc44655a730ea8c824e69b7c7bb32c1df60","./usr/share/smartupdate/kmod-tg3/component.xml"],"Name":"kmod-tg3-3.140b-1.rhel10u1.x86_64.rpm","SHA1Sum":"449d546cab5adb598c5d9391fca3bbe4c056d2b7","SHA256Sum":"eafe7d1a28bfcff40302c4e5a75294db5bb70823194a7f388dbd2325cf1d927a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.140b-1"},{"Checksum":[{"Filename":"kmod-tg3-3.140b-1.rhel10u2.x86_64.rpm","SHA1Sum":"1e609b422e8579fb4c87be9b25ad98e0792c3477","SHA256Sum":"f10e8c2b3af5151d550c7dea67d2ae2e84b611b0eee93b9f1f6cbb65346362f3","SHA512Sum":"2bd4e67bac099533c839ed263926da5bd083ab3425aeafd4743a63e43fadacec9287a18ae97b6dafd544d17a676089e326c3b807902257545d75ff4b67855381"}],"ComponentSizeInKB":163,"CompsigList":["kmod-tg3-3.140b-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/tg3.conf","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/tg3","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/tg3/tg3.ko","./usr/lib/.build-id","./usr/lib/.build-id/07","./usr/lib/.build-id/07/1366838bbe2ec41d25297a1aa18ff1ee523338","./usr/share/smartupdate/kmod-tg3/component.xml"],"Name":"kmod-tg3-3.140b-1.rhel10u2.x86_64.rpm","SHA1Sum":"1e609b422e8579fb4c87be9b25ad98e0792c3477","SHA256Sum":"f10e8c2b3af5151d550c7dea67d2ae2e84b611b0eee93b9f1f6cbb65346362f3","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6"],"TypeOfChange":"1","Version":"3.140b-1"}],"InstallationDependency":{},"Name":"HPE Broadcom tg3 Ethernet Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-tg3","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9c49ee19d58543b99d302ba61a","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","02020001","03020101","A42","U56","U61","U60","U58","U58","03030202","U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U39","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072864.exe","SHA1Sum":"d2a1c76c72bebcec6541bd63b697ee2c1f3eb887","SHA256Sum":"cff86ecdee1aa2bc6feecf58175412360296fba26fb0acd791b682dfb00c25c8","SHA512Sum":"c677777f0b33b5cdb19b50408faaf6f737c2decf58cac2499b647d8fc0f5552e55c661ca60f5bcfbf984220db99e27756abefbbeb0383cebfe9a4f495ec66247"}],"ComponentSizeInKB":949,"CompsigList":["cp072864.compsig"],"FileList":["b57nd60a.cat","b57nd60a.inf","b57nd60a.sys","cp072864.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp072864.exe","SHA1Sum":"d2a1c76c72bebcec6541bd63b697ee2c1f3eb887","SHA256Sum":"cff86ecdee1aa2bc6feecf58175412360296fba26fb0acd791b682dfb00c25c8","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3f40450a"],"TypeOfChange":"1","Version":"221.0.10.0"}],"InstallationDependency":{},"Name":"Broadcom NX1 1Gb Driver for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"b57nd60a.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_310036dd60f245e88157295894","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","U54","U54","U56","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","A59","U72","U70","U72","U68","A66","A66","U77","03030202","A72"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Management","ComponentLocation":"","CompsigCount":0,"DeviceClass":"42fc70be-bb87-4bdb-8e7c-db1c9af52957","Devices":{"Device":[{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000242","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"2.1.0"},{"DeviceName":"HPE Apollo Chassis Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"ACCE_2.1.0s.bin","InstallDurationSec":60,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000221","Version":"2.1.0"}]},"Files":[{"Checksum":[{"Filename":"ACCE_2.1.0s.fwpkg","SHA1Sum":"4b88ae979d68c2495b0184da89c051d776da8527","SHA256Sum":"b278c4def815c8291f2893c6664eaf79b31b5c10d5caa1130043f5ecfd67b144","SHA512Sum":"f0e1471227f36d46cb132ac9f87242623be9027293111340b7d19b9007d60df6b8a801863afd49fb1fb744249b87c30821cd67313eefc7c63f3a757d1fd33907"}],"ComponentSizeInKB":540,"CompsigList":[],"FileList":["ACCE_2.1.0s.bin","ACCE_2.1.0s.xml","payload.json"],"Name":"ACCE_2.1.0s.fwpkg","SHA1Sum":"4b88ae979d68c2495b0184da89c051d776da8527","SHA256Sum":"b278c4def815c8291f2893c6664eaf79b31b5c10d5caa1130043f5ecfd67b144","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000242","00000000-0000-0000-0000-00000000023a","00000000-0000-0000-0000-000000000221"],"TypeOfChange":"1","Version":"2.1.0"}],"InstallationDependency":{},"Name":"ROM Flash Universal Firmware Package - HPE Edgeline Chassis Controller Firmware","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"ACCE","SWKeyExpectedPath":"firmware:sd:ACC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8ef1372cc2f1413cafa10ecf61","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7","7.0","8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","H08","HPE Edgeline EL8000t Converged Edge System","H10","H11","H11"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel10u2.x86_64.rpm","SHA1Sum":"4fb1695f5047d5c39bccaff4ff1630dbafa537b2","SHA256Sum":"0a6ed96e2be8c81dfe4d3ef718c1f7f7dc5dd21ef80d3c28e0bdd9707185c4f1","SHA512Sum":"a896630bfe44b27e21947f9c6acd343de515da4aab4b0435d6eb057c65e76b6b5fdc7d6cea58d3a467fba95d4bf4aa75f98a525e7d81d56a8de9cfc0b4becc16"}],"ComponentSizeInKB":79,"CompsigList":["kmod-kernel-mft-mlnx-4.36.0-147.1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/kernel-mft-mlnx","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/lib/.build-id","./usr/lib/.build-id/07","./usr/lib/.build-id/07/16ba68ea84f2bc4676a279a1a209393a75dfda","./usr/lib/.build-id/52","./usr/lib/.build-id/52/9652b1fb916b832232006bf449038d7b33f9ad","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"Name":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel10u2.x86_64.rpm","SHA1Sum":"4fb1695f5047d5c39bccaff4ff1630dbafa537b2","SHA256Sum":"0a6ed96e2be8c81dfe4d3ef718c1f7f7dc5dd21ef80d3c28e0bdd9707185c4f1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"mft-4.36.0-147.rhel10u2.x86_64.rpm","SHA1Sum":"39af788486d54762d16744363a3c1ba8da2f45ee","SHA256Sum":"9b26ddff3881e26126ee541a0e3b175dde4d66c11587a50366ed80a473cd4602","SHA512Sum":"9f1b03c38b6183c33b6d1b9b033c810ea8ee2892f9898e9c85e9214da90e970f12633ba51e48c0a7c625be8e31051d6d5988fd852adf2117bbbe5cfd01b35cb6"}],"ComponentSizeInKB":29822,"CompsigList":["mft-4.36.0-147.rhel10u2.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.rhel10u2.x86_64.rpm","SHA1Sum":"39af788486d54762d16744363a3c1ba8da2f45ee","SHA256Sum":"9b26ddff3881e26126ee541a0e3b175dde4d66c11587a50366ed80a473cd4602","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecca403118","20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 10 Update 2 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4b157441ab1546209e5508f361","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-102115b30237"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","02020001","03020101","03030201"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A40","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A40_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020a","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"A40_3.80_05_28_2026.fwpkg","SHA1Sum":"8732d7e6f0a1f75669828e8ae7516935dc4247a6","SHA256Sum":"61260e5779451b1c0ce78c81757e470bcfea20a7f51442b34e6d23a65956a7e0","SHA512Sum":"52e7dea201805f95d30e4b38b0af79b4be1e352697f1b65361c1e1e5e4ebae4832948bf555fec2e3258a54efca73a309895ef0b518c186577465da46c4999643"}],"ComponentSizeInKB":32812,"CompsigList":[],"FileList":["A40_3.80_05_28_2026.signed.flash","A40_3.80_05_28_2026.xml","payload.json"],"Name":"A40_3.80_05_28_2026.fwpkg","SHA1Sum":"8732d7e6f0a1f75669828e8ae7516935dc4247a6","SHA256Sum":"61260e5779451b1c0ce78c81757e470bcfea20a7f51442b34e6d23a65956a7e0","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020a"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL385 Gen10 (A40) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A40","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_02c72a0573f849ad93254c1a37","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A40"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":2,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_322.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.22"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_322.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.22"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_322.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.22"}]},"Files":[{"Checksum":[{"Filename":"firmware-ilo5-3.22-1.1.x86_64.rpm","SHA1Sum":"2143a0fd6f30effda2156320d346a07c8f84469c","SHA256Sum":"fbea7cc7f1698284b3132678a0c21c3aeefbe2c404b1df92900deae796acf8fb","SHA512Sum":"01c79d3b83916148d8fb05752e52718a38ab6c3a872182fe5aecfc692e7d7cb985488694ea008de738c97fdc91a125166accc711a0d62646af3d9d6e258dcd57"}],"ComponentSizeInKB":33313,"CompsigList":["firmware-ilo5-3.22-1.1.x86_64_part1.compsig","firmware-ilo5-3.22-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1/CP072781.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1/ilo5_322.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-3.22-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072781.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072781.scexe"],"Name":"firmware-ilo5-3.22-1.1.x86_64.rpm","SHA1Sum":"2143a0fd6f30effda2156320d346a07c8f84469c","SHA256Sum":"fbea7cc7f1698284b3132678a0c21c3aeefbe2c404b1df92900deae796acf8fb","SoftwarePlatforms":[],"TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.22"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_00fcc9aa4af048a597e2935ba9","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","8.0","9.0","12.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U51","A47","A48","U40","U39","U47","U45","U24","U37","A46","U47","U38","U38","U48","O43","A45","U38","U38","U38","U47","U47","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U40","U50","U39","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U56","H10","U61","U60","U64","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-i40e-2.30.18-1.rhel10u1.x86_64.rpm","SHA1Sum":"dfe2bf26815254e6c95fed3b03abb2677f98413e","SHA256Sum":"4b20d1389dd1f50cad91842b752c12cc6367ebb3b5be188fea17203ce209eeec","SHA512Sum":"d0c3d59c6498b759c1adc87dd5115d03b4dae02ab573c9a0f6602b95967df7c0eb692ef58dd793d9a2b8747eefa271e8bdd7ae90ac2eab3a72f1d7232fe162d6"}],"ComponentSizeInKB":541,"CompsigList":["kmod-i40e-2.30.18-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-i40e.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/i40e/i40e.ko","./usr/share/doc/kmod-i40e","./usr/share/doc/kmod-i40e/COPYING","./usr/share/doc/kmod-i40e/README","./usr/share/doc/kmod-i40e/pci.updates","./usr/share/man/man7/i40e.7.gz","./usr/share/smartupdate/kmod-i40e/component.xml"],"Name":"kmod-i40e-2.30.18-1.rhel10u1.x86_64.rpm","SHA1Sum":"dfe2bf26815254e6c95fed3b03abb2677f98413e","SHA256Sum":"4b20d1389dd1f50cad91842b752c12cc6367ebb3b5be188fea17203ce209eeec","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec805649d9"],"TypeOfChange":"1","Version":"2.30.18-1"},{"Checksum":[{"Filename":"kmod-i40e-2.30.18-1.rhel10u2.x86_64.rpm","SHA1Sum":"8bc68257811da54817eb2db71ecf9375d67346af","SHA256Sum":"baaf0058ddd28aa6394f8a9910a464462e05dfd837056a40a10f99b2b2123e04","SHA512Sum":"b6fc8a485a3fb3a995f1ab6fad5aaa78e62eaa9d9b785b08ebba3482ece5cbb1b741c3a88edeac92c0ade66747b014aa1ee7e6cf8469bb40d240ee5e4ebd1804"}],"ComponentSizeInKB":541,"CompsigList":["kmod-i40e-2.30.18-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/kmod-i40e.conf","./lib/modules/6.12.0-211.7.1.el10_2.x86_64/extra/i40e/i40e.ko","./usr/share/doc/kmod-i40e","./usr/share/doc/kmod-i40e/COPYING","./usr/share/doc/kmod-i40e/README","./usr/share/doc/kmod-i40e/pci.updates","./usr/share/man/man7/i40e.7.gz","./usr/share/smartupdate/kmod-i40e/component.xml"],"Name":"kmod-i40e-2.30.18-1.rhel10u2.x86_64.rpm","SHA1Sum":"8bc68257811da54817eb2db71ecf9375d67346af","SHA256Sum":"baaf0058ddd28aa6394f8a9910a464462e05dfd837056a40a10f99b2b2123e04","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec805649d9"],"TypeOfChange":"1","Version":"2.30.18-1"}],"InstallationDependency":{},"Name":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-i40e","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1a52709e4c5947b2bfe3f847d1","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-elx-lpfc-14.4.731.20-1.rhel9u8.x86_64.rpm","SHA1Sum":"e5217617de418af3c81e11a6b5e1a4d6545bb449","SHA256Sum":"dc98068ea22feb240e4e71ceaa110411bbe76fce5483b38ba4390fcf9f9af2a7","SHA512Sum":"b6d820687b9e68f8b4f708a1b4410fe81b602f1df00a1aed7dbd7810a508b7e88bf71a129d86180721f8ee159c764882ae9a40c9bf7d0e0ab2f9e8e8f920f4f8"}],"ComponentSizeInKB":805,"CompsigList":["kmod-elx-lpfc-14.4.731.20-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/elx-lpfc","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"Name":"kmod-elx-lpfc-14.4.731.20-1.rhel9u8.x86_64.rpm","SHA1Sum":"e5217617de418af3c81e11a6b5e1a4d6545bb449","SHA256Sum":"dc98068ea22feb240e4e71ceaa110411bbe76fce5483b38ba4390fcf9f9af2a7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 9 Server Update 8 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0f94a53064be4a13acc85b7401","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles16sp0.x86_64.rpm","SHA1Sum":"55be3bf6c2f08c20bd6cff25e90bb3a8acbe32cd","SHA256Sum":"e3e758462525856a308ae9df7ea7b503c72939df5b01e1759858155748838731","SHA512Sum":"e23b05cd0da72f92cf74c69332f5f6a8163d116a87b7d9df681094141c88bc49a2bcba64bf463ac31fd99ed1d90433ce1188ca191a64e7a54232b2b489520bc2"}],"ComponentSizeInKB":2345,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles16sp0.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/libexec/mlx4-setup.sh","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/mlnx-ofa_kernel","./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/perftest","./usr/share/doc/packages/perftest/COPYING","./usr/share/doc/packages/perftest/README","./usr/share/doc/packages/perftest/runme","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles16sp0.x86_64.rpm","SHA1Sum":"55be3bf6c2f08c20bd6cff25e90bb3a8acbe32cd","SHA256Sum":"e3e758462525856a308ae9df7ea7b503c72939df5b01e1759858155748838731","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"mlnx-ofa_kernel-kmp-default-26.04_k6.12.0_160000.5-OFED.26.04.0.8.6.1.1.sles16sp0.x86_64.rpm","SHA1Sum":"ecc2d7bc65e882dac4a59efb0a7b32f129e8f555","SHA256Sum":"750c78428e04f63eeef6ded88059b9a0c6048bcc9b384157fea4c262c56e7cb3","SHA512Sum":"0b10b10c1d4cd67e888df86db631558e3c3963b2fa7ab7c23ac28650249d3a7aeaf18758567bac6c5fc916df369ffdc80e7606eab58d705e0b0ad92373249c62"}],"ComponentSizeInKB":2707,"CompsigList":["mlnx-ofa_kernel-kmp-default-26.04_k6.12.0_160000.5-OFED.26.04.0.8.6.1.1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/compat","./usr/lib/modules/6.12.0-160000.5-default/updates/compat/mlx_compat.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/block","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/block/rnbd","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/block/rnbd/rnbd-client.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/block/rnbd/rnbd-server.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/fwctl","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/fwctl/fwctl.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/fwctl/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/fwctl/mlx5/mlx5_fwctl.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_cm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_core.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_ucm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_umad.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/ib_uverbs.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/iw_cm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/rdma_cm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/core/rdma_ucm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/cxgb4","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/efa","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/efa/efa.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/hfi1","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/irdma","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/irdma/irdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mana","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mana/mana_ib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mlx4","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mthca","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/ocrdma","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/qedr","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/qib","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/usnic","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/vmw_pvrdma","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/rdmavt","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/rxe","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/siw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/sw/siw/siw.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/ipoib","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/iser","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/isert","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/opa_vnic","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/rtrs","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/srp","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/srpt","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlxfw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlxsw","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme/host","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme/host/nvme-rdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme/target","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/nvme/target/nvmet-rdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vdpa","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vdpa/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vfio","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vfio/pci","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vfio/pci/mlx5","./usr/lib/modules/6.12.0-160000.5-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net","./usr/lib/modules/6.12.0-160000.5-default/updates/net/9p","./usr/lib/modules/6.12.0-160000.5-default/updates/net/9p/9pnet_rdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/mlxdevm","./usr/lib/modules/6.12.0-160000.5-default/updates/net/mlxdevm/mlxdevm.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/rds","./usr/lib/modules/6.12.0-160000.5-default/updates/net/rds/rds_rdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/smc","./usr/lib/modules/6.12.0-160000.5-default/updates/net/smc/smc.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/smc/smc_diag.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc/xprtrdma","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"Name":"mlnx-ofa_kernel-kmp-default-26.04_k6.12.0_160000.5-OFED.26.04.0.8.6.1.1.sles16sp0.x86_64.rpm","SHA1Sum":"ecc2d7bc65e882dac4a59efb0a7b32f129e8f555","SHA256Sum":"750c78428e04f63eeef6ded88059b9a0c6048bcc9b384157fea4c262c56e7cb3","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for SUSE LINUX Enterprise Server 16 SP0(AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_01d2bfaaf7ff40f0a8341275e8","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Firmware for DL20 Gen10 Plus","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"SC_DL20GEN10Plus_ME_06.00.03.708.signed.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"SC_DL20GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"4cdb0affacd98bee3fd9493d5e1b0e9eefbfb8d1","SHA256Sum":"175e26930057a7345bf3b14f5a25070045e2c8170565d8140324b82c9983dffb","SHA512Sum":"31006bb31e0b12b10364dbef069e1e79b0a6ccdc890726b99013c18924df950cbe247645a7524854d4c60f0cb193cf616a23dc3055345aa6ebceb8f959f1968a"}],"ComponentSizeInKB":2234,"CompsigList":[],"FileList":["payload.json","SC_DL20GEN10Plus_ME_06.00.03.708.signed.bin","SC_DL20GEN10Plus_ME_06.00.03.708.xml"],"Name":"SC_DL20GEN10Plus_ME_06.00.03.708.fwpkg","SHA1Sum":"4cdb0affacd98bee3fd9493d5e1b0e9eefbfb8d1","SHA256Sum":"175e26930057a7345bf3b14f5a25070045e2c8170565d8140324b82c9983dffb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus Servers","PackageFormat":"FWPKG","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b80ea0c364894c39803e12217a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52004TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"cp072134.exe","SHA1Sum":"e96c2317c1c11cfd344140eac3bad04937ebbe6e","SHA256Sum":"86acc823cc3cca15dbc1eb2f1835e508989a819e43cea8fdeb2611ebf9d7238c","SHA512Sum":"1aa0ecfb409782995b0f598f3ea96ab172d8c94a278914611106645b1ea89504f72e1ab40721b2f7d5a7d9f8b0d42420ac2587948c487b311ef6471fb0917a58"}],"ComponentSizeInKB":3307,"CompsigList":["cp072134.compsig"],"FileList":["cp072134.xml","cpqsetup.exe","M52004TBHPG4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp072134.exe","SHA1Sum":"e96c2317c1c11cfd344140eac3bad04937ebbe6e","SHA256Sum":"86acc823cc3cca15dbc1eb2f1835e508989a819e43cea8fdeb2611ebf9d7238c","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3330-3834-30475753584c"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK003840GWSXL  Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK003840GWSXL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8f573ab37db44c01ba67b0c544","SupportedDevices":["562340a5-304b-3330-3834-30475753584c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100","10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068733.exe","SHA1Sum":"61b1db87c89a90c0f9feb0a020b7dd0ea0801f05","SHA256Sum":"ee6c61a61e9be69bf9651f9cf8b923af5c3e73f66ca98dc70eba832e0c8b91c4","SHA512Sum":"f89555e03df4e0576386cbc15d56111e29078258af79268eef5fecc8bcc8060a85a93de43252988f1cf87f68d3a7ef0d65c1a8ff6524b29c2d5af20798ba9f87"}],"ComponentSizeInKB":4060,"CompsigList":["cp068733.compsig"],"FileList":["cp068733.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVANSTG1.rel"],"Name":"cp068733.exe","SHA1Sum":"61b1db87c89a90c0f9feb0a020b7dd0ea0801f05","SHA256Sum":"ee6c61a61e9be69bf9651f9cf8b923af5c3e73f66ca98dc70eba832e0c8b91c4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f4ad092bde7c4e34aa17c38fe5","SupportedDevices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a42-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"8ba236f2998b55a8aa6d9b91e8dfab2e5057ce52","SHA256Sum":"016ba4e6dfff7ada5cfc1bd122b1e93b4faf6bac387d78b13d6e404a080d89a2","SHA512Sum":"8c81b0214015d56e9175588a29c7854d07ee7f3d0faf42131be6273dc28ec9ae6b0f2c2656e227ac44bd09a5e3607cc80f504c114391ddbbf8064abf3056c60b"}],"ComponentSizeInKB":33310,"CompsigList":["firmware-system-a42-4.04_2026_04_02-1.1.x86_64_part2.compsig","firmware-system-a42-4.04_2026_04_02-1.1.x86_64_part1.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/A42_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/CP071520.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a42-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071520.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071520.scexe"],"Name":"firmware-system-a42-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"8ba236f2998b55a8aa6d9b91e8dfab2e5057ce52","SHA256Sum":"016ba4e6dfff7ada5cfc1bd122b1e93b4faf6bac387d78b13d6e404a080d89a2","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5a1272a0f2a74c92bc7882904f","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A42","A42"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-10385ef3e6-HPD2-15.1.x86_64.rpm","SHA1Sum":"330bbaabe9ea4da638b0301a24cc757a34721257","SHA256Sum":"7d3e46811527af7da5b4e1d2ff79b78196b9fe5562ea3119ee25797af0bd25ef","SHA512Sum":"461b68dd818602275cecc459d56baa88c458aa386a94be3b9a9645a1b2c3920655329f7fc8dc47cfdd9d07cff3bbec3492417b2b9dc57a2cd6272268386e5709"}],"ComponentSizeInKB":6063,"CompsigList":["firmware-hdd-10385ef3e6-HPD2-15.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/CP068931.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-15.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068931.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068931.scexe"],"Name":"firmware-hdd-10385ef3e6-HPD2-15.1.x86_64.rpm","SHA1Sum":"330bbaabe9ea4da638b0301a24cc757a34721257","SHA256Sum":"7d3e46811527af7da5b4e1d2ff79b78196b9fe5562ea3119ee25797af0bd25ef","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_27009a68f379417b83776e4d99","SupportedDevices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072283.exe","SHA1Sum":"1127b87d03fd614e27584cb1002f3c53cbc10a1e","SHA256Sum":"cf9c0d628df133003960da4f03ecdd1bcdc54f70aa169b82e53954e16cd45504","SHA512Sum":"53c0fe487c82288a342cb4e0401ba7c76632908d66c241aeaa193fe7cc6abaa89e4cc4f9b9e48c7728133ad180371647bf44f86f47d119728e410b2564d0b6fa"}],"ComponentSizeInKB":1227,"CompsigList":["cp072283.compsig"],"FileList":["cp072283.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp072283.exe","SHA1Sum":"1127b87d03fd614e27584cb1002f3c53cbc10a1e","SHA256Sum":"cf9c0d628df133003960da4f03ecdd1bcdc54f70aa169b82e53954e16cd45504","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.25.117.0"}],"InstallationDependency":{},"Name":"Intel i40ea Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ed5735e8fdb845a4969c43833f","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-157280860000","a6b1a447-382a-5a4f-8086-1572103C0000","a6b1a447-382a-5a4f-8086-158A15900000"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","H08","H08","H10","H10","H10","A42","U46","U46","A43","A43","A47","A48","U47","A46","U47","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U47","H09","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-iegen10-0.2.3.0-8.1.x86_64.rpm","SHA1Sum":"12580bac8941a23f70f709b3471a42f1fbb6953d","SHA256Sum":"84554e850710f76c18ba689b4bbafc67cc1d0c20a5b45a3b731095a1f5c9a84e","SHA512Sum":"c57978a3a8b07a701375e1269e7f0a031e09a17f564aac57e35b6f8517865ac4b405f2ced27c00017c7c513f763be8d62b73e51dfb1a2ac3a9d379f7192a2b7a"}],"ComponentSizeInKB":6327,"CompsigList":["firmware-iegen10-0.2.3.0-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/CP068486.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051154.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051154.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051155.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/cp051155.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10-0.2.3.0-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068486.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068486.scexe"],"Name":"firmware-iegen10-0.2.3.0-8.1.x86_64.rpm","SHA1Sum":"12580bac8941a23f70f709b3471a42f1fbb6953d","SHA256Sum":"84554e850710f76c18ba689b4bbafc67cc1d0c20a5b45a3b731095a1f5c9a84e","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:sd:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e91049f03c4649bd991453920d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U34","U30","U32","U31","U31","U41","U33","U40","U37","U38","U38","I43","I42","U45","U39","U39","H08","H08"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB020000JXMTP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-304a584d5450","Version":"HPD3"},{"DeviceName":"MB018000JXMTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKESD3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584d5448","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-020fc874ad-HPD3-3.1.x86_64.rpm","SHA1Sum":"58931f3ff064143a8e6620e52e79e79a612830f1","SHA256Sum":"6fdfc86e270ceb9f9abf27852270a0946fe4c2258c57a5b1f3c24543d0d78f48","SHA512Sum":"9a7966d70d56966a9624029c6c1f1210b59349a36fa625f147257c0ce6badfe86846f24e09971226d32983e9ac3440e255ac198c491ce8221e79309f4910cc78"}],"ComponentSizeInKB":6072,"CompsigList":["firmware-hdd-020fc874ad-HPD3-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/CP068840.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/SLONGSPKESD3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-020fc874ad-HPD3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068840.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068840.scexe"],"Name":"firmware-hdd-020fc874ad-HPD3-3.1.x86_64.rpm","SHA1Sum":"58931f3ff064143a8e6620e52e79e79a612830f1","SHA256Sum":"6fdfc86e270ceb9f9abf27852270a0946fe4c2258c57a5b1f3c24543d0d78f48","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000JXMTH and MB020000JXMTP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB020000JXMTP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXMTH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_46f9341a20c14989b9f4611fd9","SupportedDevices":["4d2340a5-3042-3032-3030-304a584d5450","4d2340a5-3042-3831-3030-304a584d5448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3496cc4743-HPG3-3.1.x86_64.rpm","SHA1Sum":"e0e96f283f0c4124acba8b2db0857916d92d2902","SHA256Sum":"9d791e64373b8d8fd4a0efea711dae81bc021f90392364e2162b0600d7334f31","SHA512Sum":"e694aebed2b3e6b6b3419cead44c162a917fbc0bad9fca80284dd82751a7e97abf7ed559ba75a75c5d13183437c875e69be5fbaf866f965284123a079bc92df6"}],"ComponentSizeInKB":5769,"CompsigList":["firmware-hdd-3496cc4743-HPG3-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/CP068841.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/SLONGSPKETG3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3496cc4743-HPG3-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068841.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068841.scexe"],"Name":"firmware-hdd-3496cc4743-HPG3-3.1.x86_64.rpm","SHA1Sum":"e0e96f283f0c4124acba8b2db0857916d92d2902","SHA256Sum":"9d791e64373b8d8fd4a0efea711dae81bc021f90392364e2162b0600d7334f31","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - MB018000GXMTK and MB020000GXMTQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_65c8ee31d6f74304bdfd954b3f","SupportedDevices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8fafc9efb2-HPD8-5.1.x86_64.rpm","SHA1Sum":"667073d8caeb03a11e92bcfa3902861b96a70bbd","SHA256Sum":"55113065e28e63c620ccf59b18253b23a39944acb7538de114d674b8b8619792","SHA512Sum":"2ff132e32ac2b3cdcbc8924f231744381c97185530137b25741190b798e52087a5a834a42365659e4b55de0bc7b591cc7f0f270bde6951c764052817f8dbefce"}],"ComponentSizeInKB":5478,"CompsigList":["firmware-hdd-8fafc9efb2-HPD8-5.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/CP068922.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/KARM5ALSHPD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-5.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068922.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068922.scexe"],"Name":"firmware-hdd-8fafc9efb2-HPD8-5.1.x86_64.rpm","SHA1Sum":"667073d8caeb03a11e92bcfa3902861b96a70bbd","SHA256Sum":"55113065e28e63c620ccf59b18253b23a39944acb7538de114d674b8b8619792","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d983b2865074432aa1669f5c01","SupportedDevices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U32","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U32_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000204","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073144.exe","SHA1Sum":"8849af5c93ce2d1d6a59c7d5a86efc4dd6627f4a","SHA256Sum":"084817e902d3d7ad73ef5b608b2f8321e3231b25badc58c98573b2b2ccb589fc","SHA512Sum":"91089191e7bc3458aa3a36411d1f2f4f608538a2fbdfb0c6689e03a0233ea7ce1056ab63c26ef55d18cadf39155e068ff6433d165bc08eb8e7cbccc33e1e5f31"}],"ComponentSizeInKB":11446,"CompsigList":["cp073144.compsig"],"FileList":["cp073144.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U32_3.70_08_19_2026.signed.flash"],"Name":"cp073144.exe","SHA1Sum":"8849af5c93ce2d1d6a59c7d5a86efc4dd6627f4a","SHA256Sum":"084817e902d3d7ad73ef5b608b2f8321e3231b25badc58c98573b2b2ccb589fc","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000204"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360 Gen10 (U32) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U32","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_134836513e8642bc9706dd6f4c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U32"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"cp072374.exe","SHA1Sum":"fa7dc1d79096055dd638abdb2db92b338ac5d773","SHA256Sum":"f0e0a1eac865538c5c47955210165396326538b3d1830f8bc93e774040e6b5ed","SHA512Sum":"e6f3e8fbaa4fd76d3f8fb55c9ccffb46601a82e27087c69b692e940bd01aa3870fcfcd678ddb8e25696e804782ea76ef2822cf3a6c2f95f26c00d29958b54cd5"}],"ComponentSizeInKB":27681,"CompsigList":["cp072374.compsig"],"FileList":["cp072374.xml","cpqsetup.exe","fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp072374.exe","SHA1Sum":"fa7dc1d79096055dd638abdb2db92b338ac5d773","SHA256Sum":"f0e0a1eac865538c5c47955210165396326538b3d1830f8bc93e774040e6b5ed","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.0.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for Mellanox Open Ethernet cards","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8792fb7da0f44d89a52050c82c","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"692b6eb6b0235f150e545687cd8afcbf2dad6e17","SHA256Sum":"bcacf925453aca70ea9d97c03212aa50a3268e5d5d51f3eee47122b7f1789812","SHA512Sum":"a97a60aeb5d7da2f3b09092c6d477d1b255d7c291095246670e7e3cf7bcf10e97b90c0e4c89006f2ba5eb2f761298d69481e0328f3f2c9cadf9bf7c3d8f8d464"}],"ComponentSizeInKB":1483,"CompsigList":["hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"Name":"hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"692b6eb6b0235f150e545687cd8afcbf2dad6e17","SHA256Sum":"bcacf925453aca70ea9d97c03212aa50a3268e5d5d51f3eee47122b7f1789812","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"TypeOfChange":"1","Version":"5.3.36-1"},{"Checksum":[{"Filename":"hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"cf6c4a2249a9ebf0257cd5ca093b71d44a226423","SHA256Sum":"1e58e6c041b818eb082207c4c4cbcfedfcd0fdbdb51aee28ea63bd49ac419721","SHA512Sum":"6fceb4a51618ee5f1dc24a531bd4c2440418ae71d51baa0dcb334202563c04bdd1deaf0f337a34a1a82ae715792a2651c768f7e1fb9e597346f215f5a9df5d34"}],"ComponentSizeInKB":88,"CompsigList":["hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbevf.conf","./etc/dracut.conf.d/hp-ixgbevf-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbevf","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbevf/ixgbevf.ko","./usr/share/smartupdate/hp-ixgbevf-kmp-default/component.xml"],"Name":"hp-ixgbevf-kmp-default-5.3.36_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"cf6c4a2249a9ebf0257cd5ca093b71d44a226423","SHA256Sum":"1e58e6c041b818eb082207c4c4cbcfedfcd0fdbdb51aee28ea63bd49ac419721","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecc0badb49"],"TypeOfChange":"1","Version":"5.3.36-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbevf Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbevf-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fef8f994b9ac4588ae27e311a3","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30525a575550","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30525a575551","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30525a575552","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30525a575556","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30525a575554","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30525a575641","Version":"HPD1"},{"DeviceName":"Kioxia-RM6-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Kioxia_RM6_KARM6ALSHPD1.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30525a575555","Version":"HPD1"}]},"Files":[{"Checksum":[{"Filename":"Kioxia_RM6_KARM6ALSHPD1.fwpkg","SHA1Sum":"cf427842c7a2529914edf395b4b2de49317e46af","SHA256Sum":"7aa9bfd38c3345367cf5ea56ccbfd853b81a59a92dc9c9a262f3edd4242dcecc","SHA512Sum":"5dfb9b7aac876057e507009462efa93f99a2079dcd7dd7ee33eaeb20b89be75a667d4c5f100237f237e1d6e2a2c50777db757fd7fedfb139c97b4e84fc0e40a8"}],"ComponentSizeInKB":1131,"CompsigList":[],"FileList":["Kioxia_RM6_KARM6ALSHPD1.HPb","Kioxia_RM6_KARM6ALSHPD1.xml","payload.json"],"Name":"Kioxia_RM6_KARM6ALSHPD1.fwpkg","SHA1Sum":"cf427842c7a2529914edf395b4b2de49317e46af","SHA256Sum":"7aa9bfd38c3345367cf5ea56ccbfd853b81a59a92dc9c9a262f3edd4242dcecc","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-30525a575550","562340a5-304f-3030-3936-30525a575551","562340a5-304f-3130-3932-30525a575552","562340a5-304f-3130-3932-30525a575556","562340a5-304f-3330-3834-30525a575554","562340a5-304f-3330-3834-30525a575641","562340a5-304f-3730-3638-30525a575555"],"TypeOfChange":"1","Version":"HPD1"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - VO000960RZWUP, VO000960RZWUQ, VO001920RZWUR, VO001920RZWUV, VO003840RZWUT, VO003840RZWVA and VO007680RZWUU","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO007680RZWUU","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RZWVA","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RZWUT","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RZWUV","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RZWUR","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RZWUQ","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RZWUP","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9f078413ab6e4fb6aeab7cecca","SupportedDevices":["562340a5-304f-3030-3936-30525a575550","562340a5-304f-3030-3936-30525a575551","562340a5-304f-3130-3932-30525a575552","562340a5-304f-3130-3932-30525a575556","562340a5-304f-3330-3834-30525a575554","562340a5-304f-3330-3834-30525a575641","562340a5-304f-3730-3638-30525a575555"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072870.exe","SHA1Sum":"4a5190e8b3f7eb6edbb5c8462c25fa9674b5be2f","SHA256Sum":"5a115428a6087e484b2125f2e2cc928e46d26cc1986cd76bf57d2d94d4e12ccc","SHA512Sum":"79c084622ad5ec7d3f17493ee356c4e9c41cb2a5384759416757b1d0671543b78084b6b8732b967a57836f040d0ae27fff6dc0bed84dc66692c0b5c984c0132a"}],"ComponentSizeInKB":26972,"CompsigList":["cp072870.compsig"],"FileList":["CHIF/","CHIF/X64/","cp069672.exe","cp069674.exe","cp069676.exe","cp069698.exe","cp069722.exe","cp069724.exe","cp072870.xml","cpqsetup.exe","cp_data.xml","HPSUT/","HPSUT/X64/","install.xml","multisetup.dll","sut.msi","sutinstaller.exe","sut_cfg_default.dat","sut_config_en.xml","sut_config_ja.xml"],"Name":"cp072870.exe","SHA1Sum":"4a5190e8b3f7eb6edbb5c8462c25fa9674b5be2f","SHA256Sum":"5a115428a6087e484b2125f2e2cc928e46d26cc1986cd76bf57d2d94d4e12ccc","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4db0e49b"],"TypeOfChange":"1","Version":"6.9.0.0"}],"InstallationDependency":{},"Name":"Integrated Smart Update Tools for Windows x64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"sut.exe","SWKeyExpectedPath":"%ProgramFiles%\\SUT\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ef17a1d5308f446b885feeefb1","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-33061590027f","a6b1a447-382a-5a4f-103c-33071590027f","a6b1a447-382a-5a4f-103c-3306159003ba","a6b1a447-382a-5a4f-103c-3307159003ba","a6b1a447-382a-5a4f-102b-053a159004bd","a6b1a447-382a-5a4f-103c-3307159004bd","a6b1a447-382a-5a4f-103c-3306159004bd"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A56","A56","A55","A55","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","U37","A46","U47","U38","U38","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","A42","U56","U61","U60","U64","U46","I43","I45","I44","I42","U59","U63","U65","U65","U58","U63","U71","U69","U69","U68","U68","U68","U72","U70","U66","U71","U72","I46","U68","HPE ProLiant DL380m Gen12","U77","H08","H08","H10","U54","U54","U57","U65","H11","A58","A66","U74","A66","U71","U34","U39","A72","HPE ProLiant Compute DL384VR Gen13","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071514.exe","SHA1Sum":"ca8e7b7534f6f845fbc21815f8bed6a68b0d5385","SHA256Sum":"72a0557963c09f47ec692ed53c75fa67e0c2b5fd337585a3b437e849cd736305","SHA512Sum":"53a217893cc48a9d8d552b05a6cb7d37b8bbd651983fb3c4c308381cc610ed72b7e2d0dc4bd4d34446c9e32029f8b0d7a6fb828b110eb272e71315e97045612c"}],"ComponentSizeInKB":33443,"CompsigList":["cp071514_part1.compsig","cp071514_part2.compsig"],"FileList":["A43_4.04_04_02_2026.signed.flash","cp071514.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071514.exe","SHA1Sum":"ca8e7b7534f6f845fbc21815f8bed6a68b0d5385","SHA256Sum":"72a0557963c09f47ec692ed53c75fa67e0c2b5fd337585a3b437e849cd736305","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_177c1fd153c546f19de544df3b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A43","A43","A43"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"CP070944.zip","SHA1Sum":"769247ee17b9fbe3e7758e929ace4f85f61cd280","SHA256Sum":"413d0964f1ad4a301c9c6f5f83de003dfb3c646a27c28d9e51b1aa5fc71e0a46","SHA512Sum":"ff0f7e8cb3f229b3fb1ccee5350fbf118c7058953f88925b80ea4653ae19da8567273befb325e3b47aa15add3f78819e15bb6fbf08b1d2571a55ebd1fe201a94"}],"ComponentSizeInKB":18946,"CompsigList":["CP070944.compsig"],"FileList":["/CP070944_BUILD_4.data","/CP070944.vmexe64","/CP070944.vmfile","/CP070944_VMw.zip","/CP070944.xml","/payload.json","/CP070944_VMw.zip/index.xml","/CP070944_VMw.zip/vendor-index.xml","/CP070944_VMw.zip/metadata.zip","/CP070944_VMw.zip/vib20/CP070944/HPE_bootbank_CP070944_HPG6.4-8.0.0.20613240.vib","/CP070944_VMw.zip/metadata.zip/vendor-index.xml","/CP070944_VMw.zip/metadata.zip/vmware.xml","/CP070944_VMw.zip/metadata.zip/vibs/CP070944--5501498643801557585.xml","/CP070944_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070944_HPG6.4-8.0.0.20613240.xml"],"Name":"CP070944.zip","SHA1Sum":"769247ee17b9fbe3e7758e929ace4f85f61cd280","SHA256Sum":"413d0964f1ad4a301c9c6f5f83de003dfb3c646a27c28d9e51b1aa5fc71e0a46","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP070944","Version":"HPG6.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_47742ac5bd55468d8b87a10d45","SupportedDevices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD6"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD6"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD6"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp070058.exe","SHA1Sum":"66d0faf63ec3031c65dd7fe366947041cccd4a2a","SHA256Sum":"7ebfa3197ebc7db127870af975b864c84d8ba1356a5d748708a925d710f73d4f","SHA512Sum":"5a52d50b7d0060275abaf8d255bf9f62b1d9b1c016a9584ee9e6fa474ad357410ce9bc4ea834d2370fb2420f74d7852fbfffe33e3be8d5e53fa749e9eedb775a"}],"ComponentSizeInKB":4082,"CompsigList":["cp070058.compsig"],"FileList":["cp070058.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG09scHPD6.REL"],"Name":"cp070058.exe","SHA1Sum":"66d0faf63ec3031c65dd7fe366947041cccd4a2a","SHA256Sum":"7ebfa3197ebc7db127870af975b864c84d8ba1356a5d748708a925d710f73d4f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f811131bece14cf8bf32f4ab99","SupportedDevices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Files":[{"Checksum":[{"Filename":"CP072201.zip","SHA1Sum":"6e43acf483ff1667d1799d52ca1d95cc25703fec","SHA256Sum":"f741cfee18a3dafe61689a5e5bb1c0844d211e02789abf2f1c854ab73809e1ff","SHA512Sum":"44af0e81df0f494ee9c36fd34c6928864a317927765f34cf6b58cc5b047d8e034d4deb3320a43daf39b3afec4dcbed16366992a2871c805abf7292b0a7daacda"}],"ComponentSizeInKB":8094,"CompsigList":["CP072201.compsig"],"FileList":["/CP072201_BUILD_1.data","/CP072201.vmcfg","/CP072201.vmexe64","/CP072201.vmfile","/CP072201_VMw.zip","/CP072201.xml","/payload.json","/CP072201_VMw.zip/index.xml","/CP072201_VMw.zip/vendor-index.xml","/CP072201_VMw.zip/metadata.zip","/CP072201_VMw.zip/vib20/CP072201/HPE_bootbank_CP072201_2.74.1-8.0.0.20613240.vib","/CP072201_VMw.zip/metadata.zip/vendor-index.xml","/CP072201_VMw.zip/metadata.zip/vmware.xml","/CP072201_VMw.zip/metadata.zip/vibs/CP072201--7509126339200158816.xml","/CP072201_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072201_2.74.1-8.0.0.20613240.xml"],"Name":"CP072201.zip","SHA1Sum":"6e43acf483ff1667d1799d52ca1d95cc25703fec","SHA256Sum":"f741cfee18a3dafe61689a5e5bb1c0844d211e02789abf2f1c854ab73809e1ff","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74","VibList":[{"Name":"CP072201","Version":"2.74.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for VMware (ESXi)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_402bcd7460114831b54fa922f2","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U46"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 2-port QSFP28 MCX516A-CCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715B30117","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ MCX4121A-XCHT Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30102","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 10Gb/25Gb 2-port SFP28 MCX4621A-ACAB OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101515B30047","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-open-mellanox-eth-mft-1.0.15-1.1.x86_64.rpm","SHA1Sum":"0b573c9bf08f488d2b1aa6ac652b473655b35dd0","SHA256Sum":"a1ae7fbba20393aa2a953a3655912848de9318fd9f39f901a72b36855bd0d7ee","SHA512Sum":"b3df347841829902b047740590465012a835efb6875d4a8188a652ea39bb5eeef3eb8fbab8db85948a0ef2c3cfe0b22358a54265baf70ee89a35effbe3783acb"}],"ComponentSizeInKB":8500,"CompsigList":["firmware-nic-open-mellanox-eth-mft-1.0.15-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/CP072373.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-MCX4121A-XCH_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-MCX4621A-ACA_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-MCX516A-CCH_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-open-mellanox-eth-mft-1.0.15-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072373.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072373.scexe"],"Name":"firmware-nic-open-mellanox-eth-mft-1.0.15-1.1.x86_64.rpm","SHA1Sum":"0b573c9bf08f488d2b1aa6ac652b473655b35dd0","SHA256Sum":"a1ae7fbba20393aa2a953a3655912848de9318fd9f39f901a72b36855bd0d7ee","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715B30117","a6b1a447-382a-5a4f-15B3-101515B30102","a6b1a447-382a-5a4f-15B3-101515B30047"],"TypeOfChange":"1","Version":"1.0.15"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for Mellanox Open Ethernet cards","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_Open_NIC_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4a736a953ed24711b39f9e1fd7","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["6.0","11.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U30","A42","U46","U32","A43","A43","A43","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLHCCBA0HPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"CP072337.zip","SHA1Sum":"d30e8d85d47d2d8e7c4458cd83840c9befa09b64","SHA256Sum":"09d496dd5fd9e0ada16cd834fc53156608be7a6dabe0efcfd77b8870b26a401c","SHA512Sum":"a556f138b06c2305eb907c2aa2b9cd4079dc0a39b1be1ce52c4883d041f84bcbd5820039f9adc79bea67e7bf5c70b39cd7ac1b4acf3791d9956971b1a6cbf358"}],"ComponentSizeInKB":19948,"CompsigList":["CP072337.compsig"],"FileList":["/CP072337_BUILD_3.data","/CP072337.vmexe64","/CP072337.vmfile","/CP072337_VMw.zip","/CP072337.xml","/payload.json","/CP072337_VMw.zip/index.xml","/CP072337_VMw.zip/vendor-index.xml","/CP072337_VMw.zip/metadata.zip","/CP072337_VMw.zip/vib20/CP072337/HPE_bootbank_CP072337_HPD5.3-8.0.0.20613240.vib","/CP072337_VMw.zip/metadata.zip/vendor-index.xml","/CP072337_VMw.zip/metadata.zip/vmware.xml","/CP072337_VMw.zip/metadata.zip/vibs/CP072337-2721442525364836120.xml","/CP072337_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072337_HPD5.3-8.0.0.20613240.xml"],"Name":"CP072337.zip","SHA1Sum":"d30e8d85d47d2d8e7c4458cd83840c9befa09b64","SHA256Sum":"09d496dd5fd9e0ada16cd834fc53156608be7a6dabe0efcfd77b8870b26a401c","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"2","Version":"HPD5","VibList":[{"Name":"CP072337","Version":"HPD5.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB012000JWDFD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e06c8024986747a4a23292afc5","SupportedDevices":["4d2340a5-3042-3231-3030-304a57444644"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"cp068761.exe","SHA1Sum":"0b28732d2c1fdb1eec129fb44593983d1d82837f","SHA256Sum":"615cbe017d733f7b1ef0f76ea738d25cae6aa6c8b67bb57314a56fcd128cf356","SHA512Sum":"9cbaa79ea31ebbb01c31d34ce37fdb3ccdac3bb5066d19e46666b391ded03600dd9cf806695aa7ad18dc64561e2097cd45a697910483adcf5bfce86f9cbb37e5"}],"ComponentSizeInKB":3173,"CompsigList":["cp068761.compsig"],"FileList":["cp068761.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA14SXn0HPD9.REL"],"Name":"cp068761.exe","SHA1Sum":"0b28732d2c1fdb1eec129fb44593983d1d82837f","SHA256Sum":"615cbe017d733f7b1ef0f76ea738d25cae6aa6c8b67bb57314a56fcd128cf356","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_636289ed1ad14379824d9cf5ca","SupportedDevices":["452340a5-3048-3030-3330-304a5748504c","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3930-304a57485050"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068740.exe","SHA1Sum":"ccd011f0dd5486cf962427728d45682ccbc8654c","SHA256Sum":"0f9828da4575730c65185ef212845802818e87a98b31768ded464df8ac7b544a","SHA512Sum":"0b83bcd9df24c7b040e0a60994a490486636e33db2cf0c53bd8d17d0c1fa12eff273425ebbbf32d9ad9d6e7a7ddbdd3c37f364f24554f3177595c9215f8eac21"}],"ComponentSizeInKB":3960,"CompsigList":["cp068740.compsig"],"FileList":["cp068740.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SLONGSPKETG3.rel"],"Name":"cp068740.exe","SHA1Sum":"ccd011f0dd5486cf962427728d45682ccbc8654c","SHA256Sum":"0f9828da4575730c65185ef212845802818e87a98b31768ded464df8ac7b544a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB018000GXMTK and MB020000GXMTQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_129ea91123b74a9c988498381b","SupportedDevices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072273.exe","SHA1Sum":"573b0794d6319faca9949900b8b4f6124b7c4280","SHA256Sum":"68a49fcc37cba1edf006ac51bb189912a6eda8f07a68c4089d5721bca40d1de7","SHA512Sum":"8098e3b59ea362d6eaad3efe9a7cf800e2f584bf0a7ea86bc7ac4ec88911a0bb4d8eab5cf7b8c0ddf87c145f9b4ebc27176cb15d78480c72b60008aa801a97cb"}],"ComponentSizeInKB":1532,"CompsigList":["cp072273.compsig"],"FileList":["cp072273.xml","cpqsetup.exe","cp_data.xml","i40eb.cat","i40eb.inf","i40eb.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp072273.exe","SHA1Sum":"573b0794d6319faca9949900b8b4f6124b7c4280","SHA256Sum":"68a49fcc37cba1edf006ac51bb189912a6eda8f07a68c4089d5721bca40d1de7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"TypeOfChange":"1","Version":"1.25.112.0"}],"InstallationDependency":{},"Name":"HPE Intel i40eb Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40eb.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\i40eb.inf_amd64_e2860b19128ec940"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c05056a7fb51495cbb752b08cf","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"CP070923.zip","SHA1Sum":"2c900cf6a82272494a55712ffd7ad7dc3b07aab2","SHA256Sum":"ce5530ce8fc220ffe243cfe71eb58c0ec0cf100ea8661c4c60ccd7580437a600","SHA512Sum":"5acdaf2db78f163541b4f86b9302f35e15c52ac1d681c032600c49d48398aa34dea26537d46ec3dedaf285c63d19b52522818a43c4e473462095a0cc199f7dce"}],"ComponentSizeInKB":20932,"CompsigList":["CP070923.compsig"],"FileList":["/CP070923_BUILD_2.data","/CP070923.vmexe64","/CP070923.vmfile","/CP070923_VMw.zip","/CP070923.xml","/payload.json","/CP070923_VMw.zip/index.xml","/CP070923_VMw.zip/vendor-index.xml","/CP070923_VMw.zip/metadata.zip","/CP070923_VMw.zip/vib20/CP070923/HPE_bootbank_CP070923_HPG1.2-8.0.0.20613240.vib","/CP070923_VMw.zip/metadata.zip/vendor-index.xml","/CP070923_VMw.zip/metadata.zip/vmware.xml","/CP070923_VMw.zip/metadata.zip/vibs/CP070923-9035409907771952477.xml","/CP070923_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070923_HPG1.2-8.0.0.20613240.xml"],"Name":"CP070923.zip","SHA1Sum":"2c900cf6a82272494a55712ffd7ad7dc3b07aab2","SHA256Sum":"ce5530ce8fc220ffe243cfe71eb58c0ec0cf100ea8661c4c60ccd7580437a600","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1","VibList":[{"Name":"CP070923","Version":"HPG1.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives.","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ba8fd5a6656246d3a58f5f6849","SupportedDevices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE 100GbE 1p QSFP28 MCX515A-CCAT Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"16_35_8008-MCX515A-CCA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101715900346","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"16_35_8008-MCX515A-CCA_HPE_Ax.pldm.fwpkg","SHA1Sum":"c22630112fa8ce536f4682996fa74aadc95a9f8e","SHA256Sum":"46fc159c072d28a503f397490f39ab471109825affcbc30c987a5543578120a2","SHA512Sum":"48526d30e0ccbb8f17bcd6ef3d2524225dea26dd9929f6f819658778e3ed3f59e1642640bbc45a5969ed4e84a61d336895772f2f8355675c9be34e539161ab0b"}],"ComponentSizeInKB":5523,"CompsigList":[],"FileList":["16_35_8008-MCX515A-CCA_HPE_Ax.pldm.signed","16_35_8008-MCX515A-CCA_HPE_Ax.pldm.xml","payload.json"],"Name":"16_35_8008-MCX515A-CCA_HPE_Ax.pldm.fwpkg","SHA1Sum":"c22630112fa8ce536f4682996fa74aadc95a9f8e","SHA256Sum":"46fc159c072d28a503f397490f39ab471109825affcbc30c987a5543578120a2","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101715900346"],"TypeOfChange":"1","Version":"16.35.8008"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE Ethernet 100Gb 1-port QSFP28 PCIe3 x16 MCX515A-CCAT Adapter : HPE part numbers P31246-B21 and P31246-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX515A-CCAT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4dcbfa450d7e4f94a5cb148a3a","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900346"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0","10.0"]},{"OS":"VMware","Version":["7.0","8.0","6.5","6.7","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U54","U58","U58","U63","A55","A55","A56","A56","U59","U34","U34","U30","P89","U32","P89","U36","U22","U41","HPE ProLiant SL4500 Chassis","U40","U39","U45","U25","U37","U38","U38","HPE Apollo 6500 Gen10 System","U39","U19"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"CP070949.zip","SHA1Sum":"c67a8f5fce1ab7e316ce45248bcc8a7cdfa9c69a","SHA256Sum":"1b1c5b053a10fb0d701334122991f6b2367cf18ba1e1dd49d7eefcd564e0a949","SHA512Sum":"d6977f48ce34e0bb7efecb256668ef5ca6d9c1e6fa34041e06fc31d59924de81522e622f0e35e16ff01e00191de2276bb6eb02e18c4b343ee0be609c414f14b1"}],"ComponentSizeInKB":17643,"CompsigList":["CP070949.compsig"],"FileList":["/CP070949_BUILD_3.data","/CP070949.vmexe64","/CP070949.vmfile","/CP070949_VMw.zip","/CP070949.xml","/payload.json","/CP070949_VMw.zip/index.xml","/CP070949_VMw.zip/vendor-index.xml","/CP070949_VMw.zip/metadata.zip","/CP070949_VMw.zip/vib20/CP070949/HPE_bootbank_CP070949_HPD9.3-8.0.0.20613240.vib","/CP070949_VMw.zip/metadata.zip/vendor-index.xml","/CP070949_VMw.zip/metadata.zip/vmware.xml","/CP070949_VMw.zip/metadata.zip/vibs/CP070949--7028351664280872651.xml","/CP070949_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070949_HPD9.3-8.0.0.20613240.xml"],"Name":"CP070949.zip","SHA1Sum":"c67a8f5fce1ab7e316ce45248bcc8a7cdfa9c69a","SHA256Sum":"1b1c5b053a10fb0d701334122991f6b2367cf18ba1e1dd49d7eefcd564e0a949","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP070949","Version":"HPD9.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EH000900JWHPK and EH000600JWHPH   Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e72ec704d8c548e18aafd628ed","SupportedDevices":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960RWUEV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554556","Version":"HPD8"},{"DeviceName":"VO001920RWUFA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554641","Version":"HPD8"},{"DeviceName":"VO003840RWUFB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554642","Version":"HPD8"},{"DeviceName":"VO007680RWUFC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305257554643","Version":"HPD8"},{"DeviceName":"VO000960RWUFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-305257554644","Version":"HPD8"},{"DeviceName":"VO001920RWUFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305257554645","Version":"HPD8"},{"DeviceName":"VO003840RWUFF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KARM5ALSHPD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305257554646","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8fafc9efb2_0HPD8-2.1_amd64.deb","SHA1Sum":"9faf0a8333a2d7fcdb70dc891a79f2b49a063bff","SHA256Sum":"5664c7db5e1d6618a453a153f9523122667301d53220b9bb0092cb1b3b2d6ec4","SHA512Sum":"ff366250c0e788cf70f6846da7b4f1c8a3b5f82efbcfe4692aaafac3fbc99811aadcbb1051c8743bd09e0a3ec77c649714d354dad2085e4d7c157084b9484eea"}],"ComponentSizeInKB":4083,"CompsigList":["firmware-hdd-8fafc9efb2_0HPD8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/CP071812.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/KARM5ALSHPD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071812.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8fafc9efb2-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071812.scexe"],"Name":"firmware-hdd-8fafc9efb2_0HPD8-2.1_amd64.deb","SHA1Sum":"9faf0a8333a2d7fcdb70dc891a79f2b49a063bff","SHA256Sum":"5664c7db5e1d6618a453a153f9523122667301d53220b9bb0092cb1b3b2d6ec4","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-305257554556","562340a5-304f-3130-3932-305257554641","562340a5-304f-3330-3834-305257554642","562340a5-304f-3730-3638-305257554643","562340a5-304f-3030-3936-305257554644","562340a5-304f-3130-3932-305257554645","562340a5-304f-3330-3834-305257554646"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - VO000960RWUEV, VO001920RWUFA, VO003840RWUFB, VO007680RWUFC, VO000960RWUFD, VO001920RWUFE and VO003840RWUFF Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960RWUEV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680RWUFC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960RWUFD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920RWUFE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840RWUFF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d39d718821fc45bd8a67807715","SupportedDevices":["562340a5-304f-3730-3638-305257554643","562340a5-304f-3330-3834-305257554646","562340a5-304f-3330-3834-305257554642","562340a5-304f-3130-3932-305257554645","562340a5-304f-3130-3932-305257554641","562340a5-304f-3030-3936-305257554644","562340a5-304f-3030-3936-305257554556"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-mellanox-ethernet-only-1.0.25-1.1.x86_64.rpm","SHA1Sum":"b9477257f7218d2d3c9e4ecd46fe441bf87b42c9","SHA256Sum":"4bae72773bf49b15d5bb7d44909209a1095303b894acd68d58844d3c38ba311f","SHA512Sum":"bc1f18ad4f7acb37025079f6e60ada9c174d946fe802dfb493869777e24f3e237bdca5115814a1313938e511eddc57b0f2d2e1cc5450a24b5a658cb792eebea2"}],"ComponentSizeInKB":8260,"CompsigList":["firmware-nic-mellanox-ethernet-only-1.0.25-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/CP072359.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/getmlnxinfo","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/NICFWData.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/nic_fw/mstflint","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-mellanox-ethernet-only-1.0.25-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072359.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072359.scexe"],"Name":"firmware-nic-mellanox-ethernet-only-1.0.25-1.1.x86_64.rpm","SHA1Sum":"b9477257f7218d2d3c9e4ecd46fe441bf87b42c9","SHA256Sum":"4bae72773bf49b15d5bb7d44909209a1095303b894acd68d58844d3c38ba311f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.25"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Linux x86_64) for HPE Mellanox Ethernet only adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_00cdb8b1a28e4c74a15f171a37","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["6.0","11.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","U36","U22","U41","A47","A48","U40","U50","U47","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U19","U46","HPE Apollo 2000 Gen10 Plus System","U61","A41","U45","U25","U37","A42","U56","HPE ProLiant SL4500 Chassis","U39","HPE Apollo 6500 Gen10 System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069563.exe","SHA1Sum":"dcf43014910c8289908a0f93836dc0c899daf820","SHA256Sum":"5b2a9b056422849549fc7dd49cc6e20c0b6412af461767e728eac623c6f3f84c","SHA512Sum":"c9aa405b6b4341b3b258b5e140c9f95bd1a67096e03d704ebeb24e0c62548a3302884f2441b614b529273eae39e0bbcb44ec3db44d30247e0fc9b3feecf427d7"}],"ComponentSizeInKB":6354,"CompsigList":["cp069563.compsig"],"FileList":["cp069563.xml","cpqsetup.exe","cp_data.xml","DrvFil~1.cab","install.xml","multisetup.dll","QDrv4500.msi"],"Name":"cp069563.exe","SHA1Sum":"dcf43014910c8289908a0f93836dc0c899daf820","SHA256Sum":"5b2a9b056422849549fc7dd49cc6e20c0b6412af461767e728eac623c6f3f84c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45"],"TypeOfChange":"1","Version":"8.72.21.0"}],"InstallationDependency":{},"Name":"Marvell FastLinQ 10/25/50 GbE Drivers for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"qevbda.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1e029bdb27234af1b25a757bd9","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-809010770070","a6b1a447-382a-5a4f-1077-809010770069","a6b1a447-382a-5a4f-1077-809010770068","a6b1a447-382a-5a4f-1077-809010770071","a6b1a447-382a-5a4f-1077-809010770072","a6b1a447-382a-5a4f-1077-809010770074","a6b1a447-382a-5a4f-1077-809010770073"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","A47","A48","U38","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB014000JWRTH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a57525448","Version":"HPD2"},{"DeviceName":"MB012000JWRTF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57525446","Version":"HPD2"},{"DeviceName":"MB010000JWRTE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SMOBULABPSD2.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a57525445","Version":"HPD2"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-10385ef3e6_0HPD2-2.1_amd64.deb","SHA1Sum":"4ee628e55a76e1f7b269deb02e23883c20a217d9","SHA256Sum":"3b7a7386c55673df68231e88b23c271c04c33bc6b5e1b2c04915768e220a38cd","SHA512Sum":"7e98d81dec46e228b9e2ac7ccb461693865f55352d5d6226add003fdac4f35b924faae0742b7d8a2859836d794c5441c89f304bd6b975c5812074f1b01c6cacd"}],"ComponentSizeInKB":4494,"CompsigList":["firmware-hdd-10385ef3e6_0HPD2-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/CP071738.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/SMOBULABPSD2.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071738.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-10385ef3e6-HPD2-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071738.scexe"],"Name":"firmware-hdd-10385ef3e6_0HPD2-2.1_amd64.deb","SHA1Sum":"4ee628e55a76e1f7b269deb02e23883c20a217d9","SHA256Sum":"3b7a7386c55673df68231e88b23c271c04c33bc6b5e1b2c04915768e220a38cd","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"TypeOfChange":"1","Version":"HPD2"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB014000JWRTH, MB012000JWRTF and MB010000JWRTE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB014000JWRTH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWRTF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JWRTE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_599cba23c07c4fe892105310eb","SupportedDevices":["4d2340a5-3042-3431-3030-304a57525448","4d2340a5-3042-3231-3030-304a57525446","4d2340a5-3042-3031-3030-304a57525445"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051643.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Files":[{"Checksum":[{"Filename":"firmware-iegen10plus-1.0.0.22-9.1.x86_64.rpm","SHA1Sum":"514afdb399cd08ccfc22d428a171ec7f8c61da12","SHA256Sum":"68d0546178be4c47c10bb2c01daf7b4c1b7bf3e190129afc7ebc111a0e3775d0","SHA512Sum":"132ee4a1b9347eb8e8a61f4085e0760fdf93b9ea4f6b68e8b12a46ae6e80ef9a87dc71833649dd2d5a11ec6cd0f174441b4198b466287e64da267d987dc71467"}],"ComponentSizeInKB":8368,"CompsigList":["firmware-iegen10plus-1.0.0.22-9.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/CP069821.xml","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/cp051643.compsig","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/cp051643.zip","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-iegen10plus-1.0.0.22-9.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069821.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069821.scexe"],"Name":"firmware-iegen10plus-1.0.0.22-9.1.x86_64.rpm","SHA1Sum":"514afdb399cd08ccfc22d428a171ec7f8c61da12","SHA256Sum":"68d0546178be4c47c10bb2c01daf7b4c1b7bf3e190129afc7ebc111a0e3775d0","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:sd:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b751449de7e3448b90a977acbc","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","H10","U56","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-2CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_2CQDA2_O_SEC_5p0_PLDMoMCTP_80021BCE.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-15928086000e","Version":"5.00"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_2CQDA2_O_SEC_5p0_PLDMoMCTP_80021BCE.fwpkg","SHA1Sum":"da915f4d9364b73957ab345a16e9f4c9fa140d59","SHA256Sum":"b38550f955290617705e8787892d25cee33438f88ca9fc5a6911a2629726ea87","SHA512Sum":"413634c9e91e34b99f6ba53dfb5a77ba62e397fece4eebc63c7ee327c6f06ead64db7539913cfcb121d3fad6c4bccdd813ed335a72c13f773e7df09cebfb9fd3"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_2CQDA2_O_SEC_5p0_PLDMoMCTP_80021BCE.HPb","HPE_E810_2CQDA2_O_SEC_5p0_PLDMoMCTP_80021BCE.xml","payload.json"],"Name":"HPE_E810_2CQDA2_O_SEC_5p0_PLDMoMCTP_80021BCE.fwpkg","SHA1Sum":"da915f4d9364b73957ab345a16e9f4c9fa140d59","SHA256Sum":"b38550f955290617705e8787892d25cee33438f88ca9fc5a6911a2629726ea87","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15928086000e"],"TypeOfChange":"1","Version":"5.00"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_2CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a5e016527cc444da9b0595a6b8","SupportedDevices":["a6b1a447-382a-5a4f-8086-15928086000e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072195.exe","SHA1Sum":"def64366e45f9827a7e0fbf8ed527d424ebcf67b","SHA256Sum":"6c2813b7191b20603e750693aece22a0448012b2b0f3655ba39d27280c1c261b","SHA512Sum":"3a0d6cea29cad3d0b4b1cacb2b7d9fb2e97960d85b9d4b9e1b702f02f2fc6af15b979e8546e6421497835eeeeae49e9c755713640a375b550c13d97487a77766"}],"ComponentSizeInKB":2436,"CompsigList":["cp072195.compsig"],"FileList":["cp072195.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072195.exe","SHA1Sum":"def64366e45f9827a7e0fbf8ed527d424ebcf67b","SHA256Sum":"6c2813b7191b20603e750693aece22a0448012b2b0f3655ba39d27280c1c261b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"HPE Mellanox CX4LX and CX5 Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_92472a6ca478452185dc8bf4d4","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159002c1","a6b1a447-382a-5a4f-15b3-1016159000d3","a6b1a447-382a-5a4f-15b3-1016159000d4","a6b1a447-382a-5a4f-15b3-101815900246"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","U34","U34","A40","U30","P89","U32","P89","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"238.1.169000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"238.1.169000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"238.1.169000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"238.1.169000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"238.1.169000"}]},"Files":[{"Checksum":[{"Filename":"CP072711.zip","SHA1Sum":"e0a364f1cdbca06f45e2a610618dc47c18fcaa57","SHA256Sum":"69405045c454503ce12e006d2af5085f9760dc19e5d281240d3d6b64fe489ec8","SHA512Sum":"670a86c32f9d52c1cfe083fb67e3c7bf60f2a084cdb6f42d51f4a9369bb8755049a0f2d86089775185d93458fed7d7a52d2edafe379cf555916c72ed3933f3de"}],"ComponentSizeInKB":16425,"CompsigList":["CP072711.compsig"],"FileList":["/CP072711_BUILD_3.data","/CP072711.vmexe64","/CP072711.vmfile","/CP072711_VMw.zip","/CP072711.xml","/payload.json","/CP072711_VMw.zip/index.xml","/CP072711_VMw.zip/vendor-index.xml","/CP072711_VMw.zip/metadata.zip","/CP072711_VMw.zip/vib20/CP072711/HPE_bootbank_CP072711_5.29.0.3-8.0.0.20613240.vib","/CP072711_VMw.zip/metadata.zip/vendor-index.xml","/CP072711_VMw.zip/metadata.zip/vmware.xml","/CP072711_VMw.zip/metadata.zip/vibs/CP072711-4333144508793849910.xml","/CP072711_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072711_5.29.0.3-8.0.0.20613240.xml"],"Name":"CP072711.zip","SHA1Sum":"e0a364f1cdbca06f45e2a610618dc47c18fcaa57","SHA256Sum":"69405045c454503ce12e006d2af5085f9760dc19e5d281240d3d6b64fe489ec8","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"5.29.0","VibList":[{"Name":"CP072711","Version":"5.29.0.3-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f0ba2843979343a38bec1e1f86","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03030201","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_OCP3_9p57_CFGID7p2_K97342_80010346.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.4002.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_9p57_CFGID7p2_K97470_80010350.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.4002.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.4002.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.4002.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.4002.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.4002.0"}]},"Files":[{"Checksum":[{"Filename":"CP072308.zip","SHA1Sum":"a4d57b728b4223e7b048e3f24cb914494b6f61dc","SHA256Sum":"e3202086079635dc80b68dbd4c632ec2b2ec52a94fe0ba8d4a3cff36486350b1","SHA512Sum":"8490c5a4ceb1a7f02601a02d971e7eb9e63e0ad08967062272c959b2f40aa41e5f8b05be3b68610a1dd4847f4c2dc7bf63f3ae4720e7f23dcdbc18fd63a30d4e"}],"ComponentSizeInKB":6654,"CompsigList":["CP072308.compsig"],"FileList":["/CP072308_BUILD_8.data","/CP072308_VMw.zip","/CP072308.xml","/payload.json","/CP072308_VMw.zip/index.xml","/CP072308_VMw.zip/vendor-index.xml","/CP072308_VMw.zip/metadata.zip","/CP072308_VMw.zip/vib20/CP072308/HPE_bootbank_CP072308_3.30.0.8-8.0.0.20613240.vib","/CP072308_VMw.zip/metadata.zip/vendor-index.xml","/CP072308_VMw.zip/metadata.zip/vmware.xml","/CP072308_VMw.zip/metadata.zip/vibs/CP072308--4409263906899120015.xml","/CP072308_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072308_3.30.0.8-8.0.0.20613240.xml"],"Name":"CP072308.zip","SHA1Sum":"a4d57b728b4223e7b048e3f24cb914494b6f61dc","SHA256Sum":"e3202086079635dc80b68dbd4c632ec2b2ec52a94fe0ba8d4a3cff36486350b1","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"3.30.0","VibList":[{"Name":"CP072308","Version":"3.30.0.8-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca93656a5","SWKey":"kmod-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec805649d9","SWKey":"kmod-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","SWKey":"i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Intel-i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Intel Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"IS_INTEL","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e13a7424821740d3a9f4e6a8eb","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","A42","U46","U46","A43","A47","A48","A46","U47","U48","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","A42","U46","U77","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"CP070934.zip","SHA1Sum":"8d016657c63a4c5f4b95d71315c3ba9ea7649a38","SHA256Sum":"ee4bdfbb457955a624c5d1b75c52f6fd8f90014c70dd2235fd64aa927688021e","SHA512Sum":"315ba0573e9ed85ed349c14d29e29714814df725d93b4a79773f478347adf6019c5a5097f431ca06350167200417d3958f92d74f851a3ec3d08ef6a527e76047"}],"ComponentSizeInKB":19184,"CompsigList":["CP070934.compsig"],"FileList":["/CP070934_BUILD_2.data","/CP070934.vmexe64","/CP070934.vmfile","/CP070934_VMw.zip","/CP070934.xml","/payload.json","/CP070934_VMw.zip/index.xml","/CP070934_VMw.zip/vendor-index.xml","/CP070934_VMw.zip/metadata.zip","/CP070934_VMw.zip/vib20/CP070934/HPE_bootbank_CP070934_HPDB.2-8.0.0.20613240.vib","/CP070934_VMw.zip/metadata.zip/vendor-index.xml","/CP070934_VMw.zip/metadata.zip/vmware.xml","/CP070934_VMw.zip/metadata.zip/vibs/CP070934--8801092302076112374.xml","/CP070934_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070934_HPDB.2-8.0.0.20613240.xml"],"Name":"CP070934.zip","SHA1Sum":"8d016657c63a4c5f4b95d71315c3ba9ea7649a38","SHA256Sum":"ee4bdfbb457955a624c5d1b75c52f6fd8f90014c70dd2235fd64aa927688021e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP070934","Version":"HPDB.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_57188dbcaef94870b9cefff622","SupportedDevices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b5a595755","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b5a595842","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b5a595843","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b5a595754","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b5a595756","Version":"HPK5"},{"DeviceName":"Solidigm-P5x20-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Solidigm_P5x20_4IAAHPK5.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b5a595841","Version":"HPK5"}]},"Files":[{"Checksum":[{"Filename":"Solidigm_P5x20_4IAAHPK5.fwpkg","SHA1Sum":"4d418d328eece3582d53f2fd39f9304c156d1aa4","SHA256Sum":"da95c519e100811f753c052858be793683375405746f7285c42b897183e9079f","SHA512Sum":"7f6ac335147d901db5f8ecdb5300fc8c0211a5ab6044ca515ee8b103388bb46d7c8eaba827f450778ca0f40423c67c10c98e052ea20decd69ae2d905c5562f92"}],"ComponentSizeInKB":1559,"CompsigList":[],"FileList":["payload.json","Solidigm_P5x20_4IAAHPK5.HPb","Solidigm_P5x20_4IAAHPK5.xml"],"Name":"Solidigm_P5x20_4IAAHPK5.fwpkg","SHA1Sum":"4d418d328eece3582d53f2fd39f9304c156d1aa4","SHA256Sum":"da95c519e100811f753c052858be793683375405746f7285c42b897183e9079f","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3130-3630-304b5a595755","4d2340a5-304f-3330-3230-304b5a595842","4d2340a5-304f-3630-3430-304b5a595843","562340a5-304f-3130-3932-304b5a595754","562340a5-304f-3330-3834-304b5a595756","562340a5-304f-3730-3638-304b5a595841"],"TypeOfChange":"1","Version":"HPK5"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  MO001600KZYWU, MO003200KZYXB, MO006400KZYXC, VO001920KZYWT, VO003840KZYWV and VO007680KZYXA","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO001600KZYWU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KZYXB","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KZYXC","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KZYWT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KZYWV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KZYXA","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4412e3e7c98649b3bd32cc53ac","SupportedDevices":["4d2340a5-304f-3130-3630-304b5a595755","4d2340a5-304f-3330-3230-304b5a595842","4d2340a5-304f-3630-3430-304b5a595843","562340a5-304f-3130-3932-304b5a595754","562340a5-304f-3330-3834-304b5a595756","562340a5-304f-3730-3638-304b5a595841"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072288.exe","SHA1Sum":"c09e4419790882266109df728edefa0ae4e4914e","SHA256Sum":"8f3f704b60981af8898caacc3b8625cd835a37b1da03f40df87e845a43fdb7ab","SHA512Sum":"802fb93660e01e81e76cb2b5126434ebf3a6fbd9ff6871a204da95b2ca9909e69cb8ca1bf72de7686b01de1a32fde50bb8ddbaa1f8e90a011ece2e7b8c4ce7e9"}],"ComponentSizeInKB":1404,"CompsigList":["cp072288.compsig"],"FileList":["cp072288.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"Name":"cp072288.exe","SHA1Sum":"c09e4419790882266109df728edefa0ae4e4914e","SHA256Sum":"8f3f704b60981af8898caacc3b8625cd835a37b1da03f40df87e845a43fdb7ab","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.19.113.0"}],"InstallationDependency":{},"Name":"Intel iavf Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_29cdcc7480464dc1a1ce18a194","SupportedDevices":["a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-188980860000","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-37cd80860001"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U50","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U50_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022b","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u50-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"1fb1228819cf85a669d9cdcfa3caddc4907fbd13","SHA256Sum":"06847274762924ccc3a2d57bb5b8369091943dbf699d9b91e5c241a8d9302068","SHA512Sum":"09370f8d3dece3fa0eea5dbbbc0af638c3fc1d1f550136d07d0640face3ed62fa746935603d941c1b1d2c91c90d8073ad79d4f542cd52af6b1ecee920861d9db"}],"ComponentSizeInKB":33293,"CompsigList":["firmware-system-u50-2.70_2026_08_19-1.1.x86_64_part1.compsig","firmware-system-u50-2.70_2026_08_19-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.70_2026_08_19-1.1/CP073125.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.70_2026_08_19-1.1/U50_2.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u50-2.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073125.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073125.scexe"],"Name":"firmware-system-u50-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"1fb1228819cf85a669d9cdcfa3caddc4907fbd13","SHA256Sum":"06847274762924ccc3a2d57bb5b8369091943dbf699d9b91e5c241a8d9302068","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022b"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 4200 Gen10 Plus/HPE ProLiant XL420 Gen10 Plus (U50) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U50","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ba6cc37a88714ba896777bc06b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U50"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-238.1.165.0-rhel10u1.x86_64.rpm","SHA1Sum":"ea89a07604724850c3db2f3b6cbb8189e6a0172c","SHA256Sum":"e9c5e0c7880db4beb58d88637b8d3a23fa413d3a5355be3e50f3ddb7b37f2428","SHA512Sum":"d19931cb8b2fa7bec91d8921ccb44733ae4d62bc3ba2893ff1c344a64543494428fb24f83cb72db7673f4f8f8fbca55dac015a158a8cfcbeb0b7ded7f7ad2257"}],"ComponentSizeInKB":59,"CompsigList":["libbnxt_re-238.1.165.0-rhel10u1.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/e7","./usr/lib/.build-id/e7/c973025c55a72a6e97b74c672c01cce9f5be72","./usr/lib64/libbnxt_re-238.1.165.0.so","./usr/lib64/libbnxt_re-rdmav57.so","./usr/lib64/libbnxt_re.so","./usr/lib64/pkgconfig/libbnxt_re.pc","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-238.1.165.0-rhel10u1.x86_64.rpm","SHA1Sum":"ea89a07604724850c3db2f3b6cbb8189e6a0172c","SHA256Sum":"e9c5e0c7880db4beb58d88637b8d3a23fa413d3a5355be3e50f3ddb7b37f2428","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 10 Update 1.","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3ce2f209b8aa442cbdd523c21f","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.70 (08/19/2026)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073147.exe","SHA1Sum":"28cd365717e8c1c6c716a7087317522325606cdc","SHA256Sum":"3c043bb6310af9601fa48ba692c0ecb78be3c3c4290c45d4241414ecfc42d6d9","SHA512Sum":"dc13f2e778819308b33fad18ae7b64c3f908d66279e0b75de598576e4e3c1befcd65d99abcfb0ff159200f13e0d33f78cba9204e696676e8d7349768aee6f40b"}],"ComponentSizeInKB":11531,"CompsigList":["cp073147.compsig"],"FileList":["cp073147.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U34_3.70_08_19_2026.signed.flash"],"Name":"cp073147.exe","SHA1Sum":"28cd365717e8c1c6c716a7087317522325606cdc","SHA256Sum":"3c043bb6310af9601fa48ba692c0ecb78be3c3c4290c45d4241414ecfc42d6d9","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c5949d244c5047fba78c7d235d","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO001920KYDMT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304b59444d54","Version":"HPK6"},{"DeviceName":"VO003840KYDMV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304b59444d56","Version":"HPK6"},{"DeviceName":"MO001600KYDMU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b59444d55","Version":"HPK6"},{"DeviceName":"MO003200KYDNC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b59444e43","Version":"HPK6"},{"DeviceName":"MO006400KYDND","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b59444e44","Version":"HPK6"},{"DeviceName":"VO007680KYDNA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304b59444e41","Version":"HPK6"},{"DeviceName":"VO015360KYDNB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM173XAHPK6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304b59444e42","Version":"HPK6"}]},"Files":[{"Checksum":[{"Filename":"CP070921.zip","SHA1Sum":"3fb3510fc3a28d5348ca1e8c23d57fce97d57336","SHA256Sum":"ca55649dda327a405b88c9b2b8f28d4dc824a12c71a59ea568da21946d9981dc","SHA512Sum":"affb53f6fc2aa33ad131a2f449847040c95b2eaaaae94575f5ddc16bab22b3aed92563ac22657c2582534e04743998480f1d931f1e860f610592c5efd9df3be9"}],"ComponentSizeInKB":22015,"CompsigList":["CP070921.compsig"],"FileList":["/CP070921_BUILD_2.data","/CP070921.vmexe64","/CP070921.vmfile","/CP070921_VMw.zip","/CP070921.xml","/payload.json","/CP070921_VMw.zip/index.xml","/CP070921_VMw.zip/vendor-index.xml","/CP070921_VMw.zip/metadata.zip","/CP070921_VMw.zip/vib20/CP070921/HPE_bootbank_CP070921_HPK6.2-8.0.0.20613240.vib","/CP070921_VMw.zip/metadata.zip/vendor-index.xml","/CP070921_VMw.zip/metadata.zip/vmware.xml","/CP070921_VMw.zip/metadata.zip/vibs/CP070921-7651242142968994756.xml","/CP070921_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070921_HPK6.2-8.0.0.20613240.xml"],"Name":"CP070921.zip","SHA1Sum":"3fb3510fc3a28d5348ca1e8c23d57fce97d57336","SHA256Sum":"ca55649dda327a405b88c9b2b8f28d4dc824a12c71a59ea568da21946d9981dc","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3330-3230-304b59444e43","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3730-3638-304b59444e41","562340a5-304f-3531-3336-304b59444e42"],"TypeOfChange":"1","Version":"HPK6","VibList":[{"Name":"CP070921","Version":"HPK6.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi  -  VO001920KYDMT, VO003840KYDMV, MO001600KYDMU, MO003200KYDNC, MO006400KYDND, VO007680KYDNA and VO015360KYDNB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO001920KYDMT","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO003840KYDMV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KYDMU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KYDNC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KYDND","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO007680KYDNA","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO015360KYDNB","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6ea014dda134467984cb0d935d","SupportedDevices":["562340a5-304f-3130-3932-304b59444d54","562340a5-304f-3330-3834-304b59444d56","4d2340a5-304f-3130-3630-304b59444d55","4d2340a5-304f-3630-3430-304b59444e44","562340a5-304f-3531-3336-304b59444e42","562340a5-304f-3730-3638-304b59444e41","4d2340a5-304f-3330-3230-304b59444e43"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Fimware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051154.zip","InstallDurationSec":120,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp051155.zip","InstallDurationSec":120,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Files":[{"Checksum":[{"Filename":"cp069587.exe","SHA1Sum":"b3167040d37f08dfe6fa35195212d97d19aac8c3","SHA256Sum":"fe8fec7dec1c06db9214fdeededda003ca8427648ea2258bf6bacfa6b8b5d154","SHA512Sum":"38117a8b93bd11fb2f1bf2ffae7dfe6ff671bd47e7151f8df9149003c1300533ee5b83fe5dd969962bc9b7a2044bb93de4bd8484c7b7181bb57da85d280b76e9"}],"ComponentSizeInKB":6757,"CompsigList":["cp069587.compsig"],"FileList":["cp051154.compsig","cp051154.zip","cp051155.compsig","cp051155.zip","cp069587.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp069587.exe","SHA1Sum":"b3167040d37f08dfe6fa35195212d97d19aac8c3","SHA256Sum":"fe8fec7dec1c06db9214fdeededda003ca8427648ea2258bf6bacfa6b8b5d154","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"InstallationDependency":{},"Name":"Online ROM Flash for Windows x64 -  HPE Gen10 Innovation Engine Firmware  for HPE Gen10 Servers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:sd:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_08a87fb5ad0840a6b85d1093a8","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U30","U32","U31","U31","U41","U33","U39","I43","I42","U34","U40","U37","U38","U38","U45","U39","H08","H08"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"8.23"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"8.23"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"8.23"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"8.23"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_8.23.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"8.23"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-f7c07bdbbd-8.23-1.1.x86_64.rpm","SHA1Sum":"3b7024224ffa5bcb703da8701d22f536c34e6e10","SHA256Sum":"092d42c293d736651a196dbdb426cb622dec106c548ca72207b2bb75059274ce","SHA512Sum":"ad505c7dbc79d8edee24677dbaa9996095617bccc56e82c8ba0517ee88ee461a45ee34100d313b211dbc7574cfa950f62da55cffd2afca82697e6a7ce458ee6e"}],"ComponentSizeInKB":9534,"CompsigList":["firmware-smartarray-f7c07bdbbd-8.23-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/CP071762.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/HPE_luxor_8.23.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-8.23-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071762.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071762.scexe"],"Name":"firmware-smartarray-f7c07bdbbd-8.23-1.1.x86_64.rpm","SHA1Sum":"3b7024224ffa5bcb703da8701d22f536c34e6e10","SHA256Sum":"092d42c293d736651a196dbdb426cb622dec106c548ca72207b2bb75059274ce","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"8.23"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7601bcbf4bb4614abc5029d86","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A41","A40"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070842.zip","SHA1Sum":"c467b1051e81dc1d0d4a4f4dedee29f9b4b1a640","SHA256Sum":"96c5d6550de70a35c2cae59a4fc2f1e0aaab3c009b1b6b9ebb296bd72566156f","SHA512Sum":"02d48ac4bc31f23c1592e90e443499e81a574b9990d53618523921543294289bef784b8bb39251f7acffce71b0767446e20845e5da64748dee69109f391eb19d"}],"ComponentSizeInKB":5694,"CompsigList":["cp070842.compsig"],"FileList":["/cp070842.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedf/QLC_bootbank_qedf_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedi/QLC_bootbank_qedi_2.74.10.0-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedentv/QLC_bootbank_qedentv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/vib20/qedrntv/QLC_bootbank_qedrntv_3.71.90.2-1OEM.800.1.0.20613240.vib","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedf-686432869232018140.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedi-5880836182664745913.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedentv-6528860809003751673.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/qedrntv-4334621844710657275.xml","/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/MRVL-E4-CNA-Driver-Bundle_6.0.420.1-1OEM.800.1.0.20613240.xml"],"Name":"cp070842.zip","SHA1Sum":"c467b1051e81dc1d0d4a4f4dedee29f9b4b1a640","SHA256Sum":"96c5d6550de70a35c2cae59a4fc2f1e0aaab3c009b1b6b9ebb296bd72566156f","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec143d8daa","20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb"],"TypeOfChange":"1","Version":"2026.03.00","VibList":[{"Name":"qedi","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedrntv","Version":"3.71.90.2-1OEM.800.1.0.20613240"},{"Name":"qedf","Version":"2.74.10.0-1OEM.800.1.0.20613240"},{"Name":"qedentv","Version":"3.71.90.2-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE QLogic FastLinQ 10/25/50 GbE Multifunction Driver for VMware vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E4-CNA-Driver-Bundle:6.0.420.1-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qedi:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedrntv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedf:2.74.10.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qedentv:3.71.90.2-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d2f4f52013f54954a4084d8963","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b","a6b1a447-382a-5a4f-1077-8090159002bd","a6b1a447-382a-5a4f-1077-809015900220","a6b1a447-382a-5a4f-1077-80901590021d","a6b1a447-382a-5a4f-1077-80901590021f"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39","U61","U60","A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","02020001","03020101","A42","U56","U46","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MK000480GZXRA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-30475a585241","Version":"HPG1"},{"DeviceName":"MK000960GZXRB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-30475a585242","Version":"HPG1"},{"DeviceName":"MK001920GZXRC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475a585243","Version":"HPG1"},{"DeviceName":"MK003840GZXRV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1PM897.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3330-3834-30475a585256","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"cp068642.exe","SHA1Sum":"f78287b419ce13242f6c7c1d3ffbdb3175f02d44","SHA256Sum":"399ddf887dba98f65b4cc790699fb38eed35be60bd01f34dab1064adb7a9684b","SHA512Sum":"b65133dc9c83c9de7892afca6d3b076c1e58f1b12252f42f18911d46cc41ad45de5508ecc442ae91c9eff465331f1d7ede6fc84bd90d353c88598f04776bc55e"}],"ComponentSizeInKB":4825,"CompsigList":["cp068642.compsig"],"FileList":["cp068642.xml","cpqsetup.exe","HPG1PM897.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068642.exe","SHA1Sum":"f78287b419ce13242f6c7c1d3ffbdb3175f02d44","SHA256Sum":"399ddf887dba98f65b4cc790699fb38eed35be60bd01f34dab1064adb7a9684b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3330-3834-30475a585256"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MK000480GZXRA, MK000960GZXRB, MK001920GZXRC and MK003840GZXRV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MK000480GZXRA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GZXRB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GZXRC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK003840GZXRV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8a0eab159b4b4e1bba5cf76f43","SupportedDevices":["4d2340a5-304b-3030-3438-30475a585241","4d2340a5-304b-3130-3932-30475a585243","4d2340a5-304b-3030-3936-30475a585242","4d2340a5-304b-3330-3834-30475a585256"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C339D","Version":"7.19.31"},{"DeviceName":"HPE Ethernet 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C18D3","Version":"7.19.31"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C1930","Version":"7.19.31"},{"DeviceName":"HPE FlexFabric 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-168E103C193A","Version":"7.19.31"},{"DeviceName":"HPE FlexFabric 10Gb 4-port 536FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A1159000EC","Version":"7.19.31"},{"DeviceName":"HPE NPAR 10Gb QP 536FLR-T","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-16A4159000EC","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 530SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C339D","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 530T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C18D3","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 533FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C193A","Version":"7.19.31"},{"DeviceName":"HP NPAR 10Gb 2-port 534FLR-SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//hp_mbi_7.19.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16AE103C1930","Version":"7.19.31"}]},"Files":[{"Checksum":[{"Filename":"CP072523.zip","SHA1Sum":"a32b6e60a4993c4c498d8803dd76fb86d9e3da54","SHA256Sum":"f3c389e36dd6af340c7efadbf86fe0c76e25fffa42d3730279a52985b46b1de6","SHA512Sum":"c66d32df34f3cb824a593c3f4d12ee30b163b6840426142fc732fe8e79d4a591249bbeea896b37a3cd2e5170710d607f3918579e9551a95253b76be202f940ef"}],"ComponentSizeInKB":12445,"CompsigList":["CP072523.compsig"],"FileList":["/CP072523_BUILD_2.data","/CP072523.vmexe64","/CP072523.vmfile","/CP072523_VMw.zip","/CP072523.xml","/payload.json","/CP072523_VMw.zip/index.xml","/CP072523_VMw.zip/vendor-index.xml","/CP072523_VMw.zip/metadata.zip","/CP072523_VMw.zip/vib20/CP072523/HPE_bootbank_CP072523_1.38.0.2-8.0.0.20613240.vib","/CP072523_VMw.zip/metadata.zip/vendor-index.xml","/CP072523_VMw.zip/metadata.zip/vmware.xml","/CP072523_VMw.zip/metadata.zip/vibs/CP072523-869630012009507315.xml","/CP072523_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072523_1.38.0.2-8.0.0.20613240.xml"],"Name":"CP072523.zip","SHA1Sum":"a32b6e60a4993c4c498d8803dd76fb86d9e3da54","SHA256Sum":"f3c389e36dd6af340c7efadbf86fe0c76e25fffa42d3730279a52985b46b1de6","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-168E103C339D","a6b1a447-382a-5a4f-14E4-168E103C18D3","a6b1a447-382a-5a4f-14E4-168E103C1930","a6b1a447-382a-5a4f-14E4-168E103C193A","a6b1a447-382a-5a4f-1077-16A1159000EC","a6b1a447-382a-5a4f-1077-16A4159000EC","a6b1a447-382a-5a4f-14E4-16AE103C339D","a6b1a447-382a-5a4f-14E4-16AE103C18D3","a6b1a447-382a-5a4f-14E4-16AE103C193A","a6b1a447-382a-5a4f-14E4-16AE103C1930"],"TypeOfChange":"1","Version":"1.38.0","VibList":[{"Name":"CP072523","Version":"1.38.0.2-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic NX2 10/20GbE Multifunction driver version 7.15.24-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec9fda3d1e","SWKey":"kmod-netxtreme2","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.15.24-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver version 7.15.24-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"15.7"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec41a44bbb","SWKey":"netxtreme2-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"7.14.69-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","DeviceGUID":"","Message":"HPE Blade QLogic NX2 10/20 GbE Multifunction Driver version 3.0.251.0-1OEM.700.1.0.15843807 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E3-Ethernet-iSCSI-FCoE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.0.251.0-1OEM.700.1.0.15843807"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic NX2 10/20 GbE Multifunction Driver 1.4.51.0-1OEM.700.1.0.15843807 or greater is required and should be already active for VMware vSphere 6.7","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","SWKey":"qfle3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.4.51.0-1OEM.700.1.0.15843807"}]}]}]},"Name":"HPE QLogic NX2 Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_NX2","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b1e684877ac84ca9a6ecaa8b95","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","U26","U30","U40","U39"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Files":[{"Checksum":[{"Filename":"cp067915.exe","SHA1Sum":"ef4a193202048ddf8f25326f5bb64b7fcd538b64","SHA256Sum":"1820502b3a39c81c96869cea71b2e8dbb3d45a7035597de3356cb1c5c85605ae","SHA512Sum":"648808a82e31765fbf026b45011e086cd5214e72d6edd263b267f2b31e9a268b0ffda55901eb4d7588d79d1167a6b24d4d97601abbc84631d8650045093b6960"}],"ComponentSizeInKB":3680,"CompsigList":["cp067915.compsig"],"FileList":["cp067915.xml","cpqsetup.exe","Eaglescanyon-Release-0.39.bin.fw","payload.json","setup.dll"],"Name":"cp067915.exe","SHA1Sum":"ef4a193202048ddf8f25326f5bb64b7fcd538b64","SHA256Sum":"1820502b3a39c81c96869cea71b2e8dbb3d45a7035597de3356cb1c5c85605ae","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f1cd8f46c3014c16bdd1409b73","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U50"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U45_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073184.exe","SHA1Sum":"2dae7e70b4c6ad59df6e6ad126fc4f3b65db9d57","SHA256Sum":"3678d4456e88f5aa7318ed1839ead266908f9d03dba172e09f20ad3644c271c8","SHA512Sum":"d3f14dd9c99e1a09c86953b7af71aede87a70531954580278f5f9f31ca21e296ba9cf67219ce5cd0f5b65bf0a7eaaa507b0595e2e9f437d705d99903429aea2c"}],"ComponentSizeInKB":11239,"CompsigList":["cp073184.compsig"],"FileList":["cp073184.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U45_3.70_08_19_2026.signed.flash"],"Name":"cp073184.exe","SHA1Sum":"2dae7e70b4c6ad59df6e6ad126fc4f3b65db9d57","SHA256Sum":"3678d4456e88f5aa7318ed1839ead266908f9d03dba172e09f20ad3644c271c8","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_584fe4c5f2494395a3c06877fb","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U45","HPE Apollo 6500 Gen10 System"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069767.exe","SHA1Sum":"963c73b55d3488d9bad718aff1e7741a824557bb","SHA256Sum":"666767566d0a396fec23febc9375d015935e749c5e4f5d67628f9e0a0b06117b","SHA512Sum":"62ed50bf850a161f8ad14cab5de4d4cf7c1eef79ed05285e0e3843058e2e263c1b85af01916fc1df0f3c7a3b60e5b32589ecd7c26de4a06cd2fe3c23f3a1c686"}],"ComponentSizeInKB":755,"CompsigList":["cp069767.compsig"],"FileList":["cp069767.xml","cpqsetup.exe","cp_data.xml","generic.dll","install.xml","smartpqi.cat","smartpqi.inf","SmartPqi.sys"],"Name":"cp069767.exe","SHA1Sum":"963c73b55d3488d9bad718aff1e7741a824557bb","SHA256Sum":"666767566d0a396fec23febc9375d015935e749c5e4f5d67628f9e0a0b06117b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec040331c1"],"TypeOfChange":"1","Version":"1016.10.0.1004"}],"InstallationDependency":{},"Name":"HPE Smart Array Gen10, Gen10Plus and Gen11 Controller Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"SmartPqi.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_29e86213c3ab4e94b0b54906f7","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f159002db","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","A43","U48","U46","U46","A42","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U60","U61","I45","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U58","U59","U63","I44","U57","U65","U65","U62","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"KCM6XVUL800G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c38303047","Version":"GPK8"},{"DeviceName":"KCM6XVUL1T60","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c31543630","Version":"GPK8"},{"DeviceName":"KCM6XVUL3T20","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c33543230","Version":"GPK8"},{"DeviceName":"KCM6XVUL6T40","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5856-554c36543430","Version":"GPK8"},{"DeviceName":"KCM6XRUL960G","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c39363047","Version":"GPK8"},{"DeviceName":"KCM6XRUL1T92","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c31543932","Version":"GPK8"},{"DeviceName":"KCM6XRUL3T84","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c33543834","Version":"GPK8"},{"DeviceName":"KCM6XRUL7T68","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KACM6ALSGPK8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"002340a5-434b-364d-5852-554c37543638","Version":"GPK8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3815d4b024_0GPK8-2.1_amd64.deb","SHA1Sum":"c1d1510f77c87d42687a0c45b5378592294c6f9f","SHA256Sum":"4058fb08ead3560c09152ff799521d67a5d0b749d20b865bce4638768060710f","SHA512Sum":"9b7a6c4755fd25395de3270f9bcba3e0ad5b1acb84c9095baad3a6641076c1ccf84d0a5ebbd3ae8fb6d1a12f29e445c9eb0cd1df78dd037dd3bdc3dd4c05eb5c"}],"ComponentSizeInKB":4773,"CompsigList":["firmware-hdd-3815d4b024_0GPK8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/CP071774.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/KACM6ALSGPK8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071774.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-3815d4b024-GPK8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071774.scexe"],"Name":"firmware-hdd-3815d4b024_0GPK8-2.1_amd64.deb","SHA1Sum":"c1d1510f77c87d42687a0c45b5378592294c6f9f","SHA256Sum":"4058fb08ead3560c09152ff799521d67a5d0b749d20b865bce4638768060710f","SoftwarePlatforms":[],"TargetGUIDs":["002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c31543630","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5852-554c37543638"],"TypeOfChange":"1","Version":"GPK8"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - KCM6XVUL800G, KCM6XVUL1T60, KCM6XVUL3T20, KCM6XVUL6T40, KCM6XRUL960G, KCM6XRUL1T92, KCM6XRUL3T84 and KCM6XRUL7T68 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"KCM6XVUL800G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL1T60","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL3T20","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XVUL6T40","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL960G","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL1T92","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL3T84","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"KCM6XRUL7T68","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_67a135eb596544f7afd0ee18b6","SupportedDevices":["002340a5-434b-364d-5852-554c39363047","002340a5-434b-364d-5852-554c37543638","002340a5-434b-364d-5852-554c31543932","002340a5-434b-364d-5856-554c33543230","002340a5-434b-364d-5852-554c33543834","002340a5-434b-364d-5856-554c38303047","002340a5-434b-364d-5856-554c36543430","002340a5-434b-364d-5856-554c31543630"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U41_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000216","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u41-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"61e6b03e6414382aafef6a6985010c777509008d","SHA256Sum":"eddfc07b73d8f013c2d184bcbe53188727147c689c49dcc87d235b52fc24d94c","SHA512Sum":"2e6a47c9b01f075c054bfd8dec68a76f8c35dd46667b3cc3fa8e009fb660dbdf52362de3c806874442dc82516005a763ce77c445a76dc7ff2904db05770db6cf"}],"ComponentSizeInKB":11311,"CompsigList":["firmware-system-u41-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.70_2026_08_19-1.1/CP073183.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.70_2026_08_19-1.1/U41_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u41-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073183.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073183.scexe"],"Name":"firmware-system-u41-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"61e6b03e6414382aafef6a6985010c777509008d","SHA256Sum":"eddfc07b73d8f013c2d184bcbe53188727147c689c49dcc87d235b52fc24d94c","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000216"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant ML350 Gen10 (U41) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2e50156c21114b7bb3a6953ec9","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","11.0","7.0","6.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U41"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"Tormore-Release-2.74-build-001.bin","InstallDurationSec":720,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"B99DFB74-F0BC-464F-B418-CD18F2A1A8E3","Version":"2.74"}]},"Files":[{"Checksum":[{"Filename":"firmware-d6020-2.74-25.1.x86_64.rpm","SHA1Sum":"233c2f7172fbdeb07fe28da1ce1368b8e0ba8a1d","SHA256Sum":"ccc8794cc5882f426560d98c018ea145fbeb8f6538413eadec12ec5886377c68","SHA512Sum":"767c2f86f6f4d4332bf7a677fb47994e287bcfc9003d5c6137380e24153cbd3cec0c969a55331af45e3b4340e61899e8cb1918f8febfdc00022d79235c13e5d1"}],"ComponentSizeInKB":3579,"CompsigList":["firmware-d6020-2.74-25.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/CP072206.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/Tormore-Release-2.74-build-001.bin","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d6020-2.74-25.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072206.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072206.scexe"],"Name":"firmware-d6020-2.74-25.1.x86_64.rpm","SHA1Sum":"233c2f7172fbdeb07fe28da1ce1368b8e0ba8a1d","SHA256Sum":"ccc8794cc5882f426560d98c018ea145fbeb8f6538413eadec12ec5886377c68","SoftwarePlatforms":[],"TargetGUIDs":["B99DFB74-F0BC-464F-B418-CD18F2A1A8E3"],"TypeOfChange":"1","Version":"2.74"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D6020 12Gb SAS Disk Enclosure ROM Flash Component for Linux (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D6020","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c4c68bcc3ffb4bb3a4c581225b","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd18f2a1a8e3"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","9.0","15.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18ab630f89","Version":"0.39"},{"DeviceName":"HPE Apollo 4200 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Eaglescanyon-Release-0.39.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd182ebbddb0","Version":"0.39"}]},"Files":[{"Checksum":[{"Filename":"CP070858.zip","SHA1Sum":"3ecbe1a606f1d82e4cc36906fe0eb98d234747f4","SHA256Sum":"421abd6ab9825e7ef5842e000f4eb388df387aaeec35d98e92b2c206b775068d","SHA512Sum":"caa9e52d464c299efa61a9b59d4fd9bca1e0798a51b01b6637afb739bfb8c955e021e57956df5e484b99b211d6bad1f4d3dd94f529bb64795448bf9ba0c30c38"}],"ComponentSizeInKB":17211,"CompsigList":["CP070858.compsig"],"FileList":["/CP070858_BUILD_4.data","/CP070858.vmexe","/CP070858.vmexe64","/CP070858.vmfile","/CP070858_VMw.zip","/CP070858.xml","/payload.json","/CP070858_VMw.zip/index.xml","/CP070858_VMw.zip/vendor-index.xml","/CP070858_VMw.zip/metadata.zip","/CP070858_VMw.zip/vib20/CP070858/HPE_bootbank_CP070858_0.39.4-8.0.0.20613240.vib","/CP070858_VMw.zip/metadata.zip/vendor-index.xml","/CP070858_VMw.zip/metadata.zip/vmware.xml","/CP070858_VMw.zip/metadata.zip/vibs/CP070858--4070673512976042868.xml","/CP070858_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070858_0.39.4-8.0.0.20613240.xml"],"Name":"CP070858.zip","SHA1Sum":"3ecbe1a606f1d82e4cc36906fe0eb98d234747f4","SHA256Sum":"421abd6ab9825e7ef5842e000f4eb388df387aaeec35d98e92b2c206b775068d","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd18ab630f89","b99dfb74-f0bc-464f-b418-cd182ebbddb0"],"TypeOfChange":"1","Version":"0.39","VibList":[{"Name":"CP070858","Version":"0.39.4-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE Apollo 4200 Gen10 Plus Backplane Expander Firmware","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"A4200 Gen10P LFF","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"A4200 Gen10P SFF","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fba1755d98dd449caaab9c67d6","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1100"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","8.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["U50"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JWDFD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLHCCBA0HPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a57444644","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-aaf1014ede_0HPD5-1.1_amd64.deb","SHA1Sum":"b54a19a87575d104fdc7de98caa8240e0655d74f","SHA256Sum":"0d2d86c766d9a23bba3ad9407c94dcb9563a8a647bec45705b7a564290aaea41","SHA512Sum":"10f605b40d1e453a9fa769ac1eb38cec2e37055ff80613d94c14003c09299ad74978adeba8d7e5073df9345dc7eaa1f150f50af653850c1c163743208f7e7268"}],"ComponentSizeInKB":4555,"CompsigList":["firmware-hdd-aaf1014ede_0HPD5-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/CP067367.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/WLHCCBA0HPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067367.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-aaf1014ede-HPD5-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067367.scexe"],"Name":"firmware-hdd-aaf1014ede_0HPD5-1.1_amd64.deb","SHA1Sum":"b54a19a87575d104fdc7de98caa8240e0655d74f","SHA256Sum":"0d2d86c766d9a23bba3ad9407c94dcb9563a8a647bec45705b7a564290aaea41","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a57444644"],"TypeOfChange":"2","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JWDFD Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JWDFD","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_35950c763c2c4db988e2b4f7d5","SupportedDevices":["4d2340a5-3042-3231-3030-304a57444644"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["26.04","24.04","22.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-238.1.165.0-rhel9u7.x86_64.rpm","SHA1Sum":"fb7feb3c0d30b0f8ddf0fb575c54afac002c59b8","SHA256Sum":"0581be0b67d7518dafd5679ee38e35bf0b65619528adae1dfa8aca92a41046d3","SHA512Sum":"b085d83dbe32b8e0e2dad235ce6a2d19366927a45f0e0d210ddc1b6bd1bac5084106d676d701476b7092294ad35fbee83d45ca0d1b8c3e4aa22d3076c2fbbfd8"}],"ComponentSizeInKB":57,"CompsigList":["libbnxt_re-238.1.165.0-rhel9u7.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/f0","./usr/lib/.build-id/f0/6717e361681388f60035e022e89924c1e09485","./usr/lib64/libbnxt_re-238.1.165.0.so","./usr/lib64/libbnxt_re-rdmav57.so","./usr/lib64/libbnxt_re.so","./usr/lib64/pkgconfig/libbnxt_re.pc","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-238.1.165.0-rhel9u7.x86_64.rpm","SHA1Sum":"fb7feb3c0d30b0f8ddf0fb575c54afac002c59b8","SHA256Sum":"0581be0b67d7518dafd5679ee38e35bf0b65619528adae1dfa8aca92a41046d3","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 7.","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb0851830a61448caf8d0705f2","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-adb3ab8147_0HPD8-2.1_amd64.deb","SHA1Sum":"93232cf52e44be40da77f3f026b33396c33844d7","SHA256Sum":"fc596b930743a87bc6d14747d30cb6b237b804cc0bb54d77dca078f55289ba6b","SHA512Sum":"f3ca777491d9893b6d6c95036ef2ae06e6a5fe9ea8711d87032a8debb66c568cfb1303612f69d2e7b2f8cd772c35573a2c29f462f719042097b70a5f845b1936"}],"ComponentSizeInKB":4378,"CompsigList":["firmware-hdd-adb3ab8147_0HPD8-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/CP071778.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/SCIMARRNNSD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071778.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071778.scexe"],"Name":"firmware-hdd-adb3ab8147_0HPD8-2.1_amd64.deb","SHA1Sum":"93232cf52e44be40da77f3f026b33396c33844d7","SHA256Sum":"fc596b930743a87bc6d14747d30cb6b237b804cc0bb54d77dca078f55289ba6b","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_20df8a847667467e8c856ba335","SupportedDevices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Files":[{"Checksum":[{"Filename":"CP070935.zip","SHA1Sum":"0d1ae151987962a8a0480d651efb03ec793c4803","SHA256Sum":"90b3b2a64ed618562b42164e4b50cf1f2db73eb3ffd4bf9f38ba24bd1a75801a","SHA512Sum":"e794d740806cfedd0db501f5693af9f35c1958da3c7221903e00aa289373e71d5f076612874b5991d827ec5190f0fd846072ae1fa3fd45ff1a11c927308d6380"}],"ComponentSizeInKB":19368,"CompsigList":["CP070935.compsig"],"FileList":["/CP070935_BUILD_5.data","/CP070935.vmexe64","/CP070935.vmfile","/CP070935_VMw.zip","/CP070935.xml","/payload.json","/CP070935_VMw.zip/index.xml","/CP070935_VMw.zip/vendor-index.xml","/CP070935_VMw.zip/metadata.zip","/CP070935_VMw.zip/vib20/CP070935/HPE_bootbank_CP070935_HPDD.5-8.0.0.20613240.vib","/CP070935_VMw.zip/metadata.zip/vendor-index.xml","/CP070935_VMw.zip/metadata.zip/vmware.xml","/CP070935_VMw.zip/metadata.zip/vibs/CP070935-491087659333760844.xml","/CP070935_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070935_HPDD.5-8.0.0.20613240.xml"],"Name":"CP070935.zip","SHA1Sum":"0d1ae151987962a8a0480d651efb03ec793c4803","SHA256Sum":"90b3b2a64ed618562b42164e4b50cf1f2db73eb3ffd4bf9f38ba24bd1a75801a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD","VibList":[{"Name":"CP070935","Version":"HPDD.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EH000600JWCPF and EH000900JWCPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c7d2059d753742e59ed30b3ade","SupportedDevices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXLR800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3830-3048c3876295","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3648ddfaa3a6","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3248a4bea716","Version":"MPK7825Q"},{"DeviceName":"MZXLR6T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3654-3448e7bd3d2a","Version":"MPK7825Q"},{"DeviceName":"MZXLR12THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3132-544869b8df72","Version":"MPK7825Q"},{"DeviceName":"MZXLR960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3936-3048d2d64915","Version":"MPK7825Q"},{"DeviceName":"MZXLR1T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3154-3948cda93afa","Version":"MPK7825Q"},{"DeviceName":"MZXLR3T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3354-3848df400867","Version":"MPK7825Q"},{"DeviceName":"MZXLR7T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3754-36484bc80db1","Version":"MPK7825Q"},{"DeviceName":"MZXLR15THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK7825Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-524c-3135-5448e88a517e","Version":"MPK7825Q"}]},"Files":[{"Checksum":[{"Filename":"cp068640.exe","SHA1Sum":"7a41ae94dcbc0083ecfdedd576b5b8c3e7129685","SHA256Sum":"b71425c25e9587f3cd160c3bc13b98972359749dd0884599232d726f9d2710c0","SHA512Sum":"f8d2c65eb5b568b9701e354ed9fbad30feae20ade5d3b5e3e03619ef628ccc22f0aad24c199c58cdee061a3bd28fc0ebb6926b2e3dc681e6caeab0aff9c17c03"}],"ComponentSizeInKB":7820,"CompsigList":["cp068640.compsig"],"FileList":["cp068640.xml","cpqsetup.exe","mnv_cli.exe","MPK7825Q.rel","payload.json","setup.dll"],"Name":"cp068640.exe","SHA1Sum":"7a41ae94dcbc0083ecfdedd576b5b8c3e7129685","SHA256Sum":"b71425c25e9587f3cd160c3bc13b98972359749dd0884599232d726f9d2710c0","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3936-3048d2d64915","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3135-5448e88a517e"],"TypeOfChange":"1","Version":"MPK7825Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - MZXLR800HBHQ-000H3, MZXLR1T6HBJR-000H3, MZXLR3T2HBLS-000H3, MZXLR6T4HALA-000H3, MZXLR12THALA-000H3, MZXLR960HBHQ-000H3, MZXLR1T9HBJR-000H3, MZXLR3T8HBLS-000H3, MZXLR7T6HALA-000H3 and MZXLR15THALA-0 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"MZXLR800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR6T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR12THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR1T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR3T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR7T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXLR15THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_058d8510e4c84af39df1c07ce8","SupportedDevices":["4d2340a5-585a-524c-3132-544869b8df72","4d2340a5-585a-524c-3135-5448e88a517e","4d2340a5-585a-524c-3754-36484bc80db1","4d2340a5-585a-524c-3154-3648ddfaa3a6","4d2340a5-585a-524c-3830-3048c3876295","4d2340a5-585a-524c-3354-3248a4bea716","4d2340a5-585a-524c-3654-3448e7bd3d2a","4d2340a5-585a-524c-3154-3948cda93afa","4d2340a5-585a-524c-3354-3848df400867","4d2340a5-585a-524c-3936-3048d2d64915"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072287.exe","SHA1Sum":"806148ec4dd6c99166f7964e0458caa91ff01fed","SHA256Sum":"e4d374c1460a19b5fcfe1d069ea0cad679b85ce0604493470379d5fa423763f5","SHA512Sum":"c0742a6bd6f090b4c41b708538ec1e89a581fe08c203802b9c70dd1c0a38be4d028cb1ea2a07f795fcc13e9d320ecebdc408f604ce750a6a7ed4697460da324b"}],"ComponentSizeInKB":1404,"CompsigList":["cp072287.compsig"],"FileList":["cp072287.xml","cpqsetup.exe","cp_data.xml","iavf.cat","iavf.inf","iavf.sys","iavfmsg.dll","install.xml","manifest_iavf.man","nicdrvr.dll"],"Name":"cp072287.exe","SHA1Sum":"806148ec4dd6c99166f7964e0458caa91ff01fed","SHA256Sum":"e4d374c1460a19b5fcfe1d069ea0cad679b85ce0604493470379d5fa423763f5","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf1d1027b"],"TypeOfChange":"1","Version":"1.19.113.0"}],"InstallationDependency":{},"Name":"Intel iavf Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"iavf.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FireRepository\\iavf.inf_amd64_7854544ffd52cc6a"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9c85fd92eee848abb3261c6049","SupportedDevices":["a6b1a447-382a-5a4f-8086-188980860001","a6b1a447-382a-5a4f-8086-157180860001","a6b1a447-382a-5a4f-8086-154c80860000","a6b1a447-382a-5a4f-8086-188980860000","a6b1a447-382a-5a4f-8086-157100000000","a6b1a447-382a-5a4f-8086-37cd80860001"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.65.31"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.65.31"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.65.31"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.65.31"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.65.31"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.65.31.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.65.31"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-qlogic-flq-1.26.0-1.1.x86_64.rpm","SHA1Sum":"bf642502510b1f7918d13b45d302137928a39145","SHA256Sum":"6bf34f4645439fc6b2c369fcaefe4a587e8d970c2fb5c2b34f79bb344e3242bb","SHA512Sum":"0c226d86d9b70f469e1e3002bdb2055cfc8cce92d0d6e0fecb08ed4b80979f1ced2be8d4880012468ab0ac71e36b72244cfa2d936a12d4eec71cca397c3ff06d"}],"ComponentSizeInKB":2199,"CompsigList":["firmware-nic-qlogic-flq-1.26.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/CP072519.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/CP072519.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/nic_fw/ql_hp_ah_mbi_8.65.31.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-1.26.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072519.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072519.scexe"],"Name":"firmware-nic-qlogic-flq-1.26.0-1.1.x86_64.rpm","SHA1Sum":"bf642502510b1f7918d13b45d302137928a39145","SHA256Sum":"6bf34f4645439fc6b2c369fcaefe4a587e8d970c2fb5c2b34f79bb344e3242bb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"1.26.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d7c754adfe624c89b2708e33fd","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072317.zip","SHA1Sum":"4e581b8cda4f5b7acbb4b5d1d769f03cc8fa5198","SHA256Sum":"b5b38eef41534d349cd3426216d7fc971ac33b89faa1db90503fb65cd8614662","SHA512Sum":"8a652ac5c774f568ba728768eeaa4b0d3f9052dfc119d113bb99e07c98523deb3141687ecf4bdc4a04596b15a17fa875a0ff8cff5f8d13777db76783b85a568a"}],"ComponentSizeInKB":587,"CompsigList":["cp072317.compsig"],"FileList":["/cp072317.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/index.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/vib20/icen/INT_bootbank_icen_2.6.5.0-1OEM.900.0.24755229.vib","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/icen-7127160694824065909.xml","/Intel-icen_2.6.5.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-icen_2.6.5.0-1OEM.900.0.24755229.xml"],"Name":"cp072317.zip","SHA1Sum":"4e581b8cda4f5b7acbb4b5d1d769f03cc8fa5198","SHA256Sum":"b5b38eef41534d349cd3426216d7fc971ac33b89faa1db90503fb65cd8614662","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece43a8459","20a6e8e4-bf33-4c71-a6bf-d9ec1fdbce15"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"icen","Version":"2.6.5.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"Intel icen Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-icen:2.6.5.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"icen:2.6.5.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_26c8365db0324935bee172dbec","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002","a6b1a447-382a-5a4f-8086-159280860006","a6b1a447-382a-5a4f-8086-159b80860003","a6b1a447-382a-5a4f-8086-159b80860005","a6b1a447-382a-5a4f-8086-159380860005","a6b1a447-382a-5a4f-8086-15928086000e","a6b1a447-382a-5a4f-8086-15938086000c","a6b1a447-382a-5a4f-8086-124a80860001","a6b1a447-382a-5a4f-8086-124a80860008","a6b1a447-382a-5a4f-8086-124a80860004","a6b1a447-382a-5a4f-8086-124a80860002","a6b1a447-382a-5a4f-8086-124980860002","a6b1a447-382a-5a4f-8086-124980860005"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U38","U38","02020001","03020101","A59","H08","H08","H10","A42","U46","U46","A43","A43","U36","J10","A47","A48","U47","U45","A46","U47","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","U60","U64","U47","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWTHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757544841","Version":"HPG5"},{"DeviceName":"VK000960GWTHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757544842","Version":"HPG5"},{"DeviceName":"VK001920GWTHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-304757544843","Version":"HPG5"},{"DeviceName":"VK003840GWTHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K401HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-304757544844","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"CP070904.zip","SHA1Sum":"8fc69fa0c87cc912cd0de3a87d86dc312dea7e15","SHA256Sum":"ca3b3bc0beef8c22a7ae2f316f7d4a73fc85026ffde4135ff349a581842948ad","SHA512Sum":"8331bd878ee38116b5e51aac4e6396f56549dcd0cf29142ea52e1dc01b1c34973e5d7781e9ae4d401ac328b691263b9267c53469d917b97286220de7eb2ecf74"}],"ComponentSizeInKB":19357,"CompsigList":["CP070904.compsig"],"FileList":["/CP070904_BUILD_5.data","/CP070904.vmexe64","/CP070904.vmfile","/CP070904_VMw.zip","/CP070904.xml","/payload.json","/CP070904_VMw.zip/index.xml","/CP070904_VMw.zip/vendor-index.xml","/CP070904_VMw.zip/metadata.zip","/CP070904_VMw.zip/vib20/CP070904/HPE_bootbank_CP070904_HPG5.5-8.0.0.20613240.vib","/CP070904_VMw.zip/metadata.zip/vendor-index.xml","/CP070904_VMw.zip/metadata.zip/vmware.xml","/CP070904_VMw.zip/metadata.zip/vibs/CP070904--8477651724788457943.xml","/CP070904_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070904_HPG5.5-8.0.0.20613240.xml"],"Name":"CP070904.zip","SHA1Sum":"8fc69fa0c87cc912cd0de3a87d86dc312dea7e15","SHA256Sum":"ca3b3bc0beef8c22a7ae2f316f7d4a73fc85026ffde4135ff349a581842948ad","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-304757544841","562340a5-304b-3030-3936-304757544842","562340a5-304b-3130-3932-304757544843","562340a5-304b-3330-3834-304757544844"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP070904","Version":"HPG5.5-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWTHA, VK000960GWTHB, VK001920GWTHC and VK003840GWTHD  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWTHA","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWTHB","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWTHC","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GWTHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f84cd5cb192c468f9ad5996508","SupportedDevices":["562340a5-304b-3330-3834-304757544844","562340a5-304b-3130-3932-304757544843","562340a5-304b-3030-3936-304757544842","562340a5-304b-3030-3438-304757544841"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072282.exe","SHA1Sum":"2f7e9e7eaaad1cbee000bdf85eda74d0812ba6f6","SHA256Sum":"ffd58e485e05f9366ca212a8a374a66945afb89f9de690ee99cd9afae04185c7","SHA512Sum":"df7097267528115fc4a6c82002d2f47ab8b7d93c9d0795302a864af9e4870cc8c50240cf738c64c03680ca01d6c58ad8db645c27584be057008ed0c01765216d"}],"ComponentSizeInKB":1228,"CompsigList":["cp072282.compsig"],"FileList":["cp072282.xml","cpqsetup.exe","cp_data.xml","i40ea.cat","i40ea.inf","i40ea.sys","i40eamsg.dll","install.xml","nicdrvr.dll"],"Name":"cp072282.exe","SHA1Sum":"2f7e9e7eaaad1cbee000bdf85eda74d0812ba6f6","SHA256Sum":"ffd58e485e05f9366ca212a8a374a66945afb89f9de690ee99cd9afae04185c7","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec688dc27a"],"TypeOfChange":"1","Version":"1.25.115.0"}],"InstallationDependency":{},"Name":"Intel i40ea Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"i40ea.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\i40ea.inf_amd64_8c025be47073d986"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a591368f984b49cfb3d02cc4fd","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-157280860000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A59","H08","H08","H10","H10","H10","A42","U46","U46","A43","A43","A47","A48","U47","A46","U47","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U47","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWWQP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a57575150","Version":"HPD8"},{"DeviceName":"MB006000JWWQN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNESD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a5757514e","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-ae6b41e855-HPD8-8.1.x86_64.rpm","SHA1Sum":"5e86971e665507a0bc0b75c0b1d7847c52dc69c8","SHA256Sum":"1395f9e09bfdfdb5e1649adaddae09959c043985775e9f84c69ac8eaa00def66","SHA512Sum":"8e7711615e673af533a1b429ed610e21e5e557b89d64705f80bd7af44b9d28a5975ac7a1de8275e896a6f714fef4d16d7a5e9a2d749e95c1b563b6059f2f0b72"}],"ComponentSizeInKB":6045,"CompsigList":["firmware-hdd-ae6b41e855-HPD8-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/CP068801.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/SCIMARRNESD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-ae6b41e855-HPD8-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068801.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068801.scexe"],"Name":"firmware-hdd-ae6b41e855-HPD8-8.1.x86_64.rpm","SHA1Sum":"5e86971e665507a0bc0b75c0b1d7847c52dc69c8","SHA256Sum":"1395f9e09bfdfdb5e1649adaddae09959c043985775e9f84c69ac8eaa00def66","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a57575150","4d2340a5-3042-3630-3030-304a5757514e"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWWQP and MB006000JWWQN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWWQP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWWQN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_582f979e397949ae897a999f64","SupportedDevices":["4d2340a5-3042-3630-3030-304a5757514e","4d2340a5-3042-3830-3030-304a57575150"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-b1c9eaf74c-HPDB-3.1.x86_64.rpm","SHA1Sum":"6afefcc2508d6b8b6d11f4c4fd8507b2d48a43f5","SHA256Sum":"78c72c76bcd1da4096a415e955e2e2550e96900ccfb86a0c79e847af37bf9d42","SHA512Sum":"5924fb60b706fe97ea9d2b397ff2f9600be06cce8b5967e8ec938784c861c648edc030b8ea8d2b9f5d1d07949c523331a4d49575963ebc2e0051b0f14c9bc091"}],"ComponentSizeInKB":6254,"CompsigList":["firmware-hdd-b1c9eaf74c-HPDB-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/CP068927.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/SSKYBT512EDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-b1c9eaf74c-HPDB-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068927.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068927.scexe"],"Name":"firmware-hdd-b1c9eaf74c-HPDB-3.1.x86_64.rpm","SHA1Sum":"6afefcc2508d6b8b6d11f4c4fd8507b2d48a43f5","SHA256Sum":"78c72c76bcd1da4096a415e955e2e2550e96900ccfb86a0c79e847af37bf9d42","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64)  - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a2bbb424bfdf4cb1a0025efc3d","SupportedDevices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"2a1ec3b1d6f2edd1d14189d0c4d1aaa57d13defa","SHA256Sum":"4ada11d1c27d383f9e05e37fea05ba21725259b2caedd6d3813059659bec3cfd","SHA512Sum":"c636dd59af8c24888c85f1be5dcbaa966b18db741792cb3f7685775cec20212884fbe923cdef72718238be6ecad67dce4cc7ebdf949a2918221821b625046b21"}],"ComponentSizeInKB":5495,"CompsigList":["qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-qla2xxx/qla2xxx.ko","./usr/lib/modules/6.12.0-160000.5-default/updates/qlgc-qla2xxx/tcm_qla2xxx.ko","./usr/lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/qlgc-qla2xxx-kmp-default/component.xml"],"Name":"qlgc-qla2xxx-kmp-default-10.02.16.00_k1_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"2a1ec3b1d6f2edd1d14189d0c4d1aaa57d13defa","SHA256Sum":"4ada11d1c27d383f9e05e37fea05ba21725259b2caedd6d3813059659bec3cfd","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb5eacdd9"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 16 Service Pack 0 Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"qlgc-qla2xxx-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_529426ce664b460680c774809b","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000600JWJNP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e50","Version":"HPD9"},{"DeviceName":"EG001200JWJNQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e51","Version":"HPD9"},{"DeviceName":"EG001200MXJQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304d584a5155","Version":"HPD9"},{"DeviceName":"EG000600JXLVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a584c5656","Version":"HPD9"},{"DeviceName":"EG001200JXLWA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512ND9.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a584c5741","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"CP070932.zip","SHA1Sum":"895f6580a5b1e69fcbae9b58759d7d1a039427f0","SHA256Sum":"34b9b706d4d4c1747b2bda877f5be15e891281353385483a2747b71e647ea06b","SHA512Sum":"f0aa00b3919584ff7fe55d618ddfa02d797e3e300a3b785bd8d33e67081fba297dd29c4e6346eadd6360a2217420a7b34fb7ed7f41469f089e1d03fbb55f82aa"}],"ComponentSizeInKB":19788,"CompsigList":["CP070932.compsig"],"FileList":["/CP070932_BUILD_6.data","/CP070932.vmexe64","/CP070932.vmfile","/CP070932_VMw.zip","/CP070932.xml","/payload.json","/CP070932_VMw.zip/index.xml","/CP070932_VMw.zip/vendor-index.xml","/CP070932_VMw.zip/metadata.zip","/CP070932_VMw.zip/vib20/CP070932/HPE_bootbank_CP070932_HPD9.6-8.0.0.20613240.vib","/CP070932_VMw.zip/metadata.zip/vendor-index.xml","/CP070932_VMw.zip/metadata.zip/vmware.xml","/CP070932_VMw.zip/metadata.zip/vibs/CP070932--6898642298238919011.xml","/CP070932_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070932_HPD9.6-8.0.0.20613240.xml"],"Name":"CP070932.zip","SHA1Sum":"895f6580a5b1e69fcbae9b58759d7d1a039427f0","SHA256Sum":"34b9b706d4d4c1747b2bda877f5be15e891281353385483a2747b71e647ea06b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP070932","Version":"HPD9.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - EG000600JWJNP, EG001200JWJNQ, EG000600JXLVV, EG001200JXLWA and EG001200MXJQU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000600JWJNP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200MXJQU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JXLVV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JXLWA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e65e99be2f1e46d5ace29d27d4","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e51","452340a5-3047-3030-3630-304a574a4e50","452340a5-3047-3130-3230-304d584a5155","452340a5-3047-3030-3630-304a584c5656","452340a5-3047-3130-3230-304a584c5741"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071624.zip","SHA1Sum":"9be1b9accfaa9c0ae2bb6b3de2c7b28ef3e53d8a","SHA256Sum":"6c66e0016b93a8d62d4dc315396dd25c6eebc05141e635c4abcb13b84255989b","SHA512Sum":"2c31359f5aba9093f84b0880885700dc4626f983d391783c5afbcd975fa167cbc2d422c8f6dabee0b3b548d9202a94d9ca10bceee3584994549490a3ff49721a"}],"ComponentSizeInKB":17268,"CompsigList":["cp071624.compsig"],"FileList":["/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip","/BCM_bootbank_storcli_007.3811.0300-1OEM.900.0.24755229.vib","/cp071624.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/index.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/vendor-index.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/vib20/storcli/BCM_bootbank_storcli_007.3811.0300-1OEM.900.0.24755229.vib","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip/vibs/storcli-9011262720796999315.xml","/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.zip/metadata.zip/bulletins/BCM-storcli_007.3811.0300-1OEM.900.0.24755229.xml"],"Name":"cp071624.zip","SHA1Sum":"9be1b9accfaa9c0ae2bb6b3de2c7b28ef3e53d8a","SHA256Sum":"6c66e0016b93a8d62d4dc315396dd25c6eebc05141e635c4abcb13b84255989b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec56ec0f9c","20a6e8e4-bf33-4c71-a6bf-d9ecfb6553be"],"TypeOfChange":"1","Version":"2026.09.01","VibList":[{"Name":"storcli","Version":"007.3811.0300-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator StorCLI for VMware9.1 (For Gen10P and Gen11  Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"BCM-storcli:007.3811.0300-1OEM.900.0.24755229","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"storcli:007.3811.0300-1OEM.900.0.24755229","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b3e0dd9db6964d29a2502ec422","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U54","U54","U54","U58","U63","U58","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","A43","A42","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","A72","U71","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL6CBA0HPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP073203.zip","SHA1Sum":"ddbf1a1d46afbd1aaa370cc2119b810a50b6177c","SHA256Sum":"23771d3e1222e9567e1c19539465ebf165e4946b4f72f0b1890a58625e2b3deb","SHA512Sum":"fb78735201ff862de2229fd55382e2cb32eebe67da4d08e140231b5e1ce057448703d021e6e56dcb82eff00baf25b4320d593c1d52d313bfff43cd8768ca580e"}],"ComponentSizeInKB":20217,"CompsigList":["CP073203.compsig"],"FileList":["/CP073203_BUILD_1.data","/CP073203.vmexe64","/CP073203.vmfile","/CP073203_VMw.zip","/CP073203.xml","/payload.json","/CP073203_VMw.zip/index.xml","/CP073203_VMw.zip/vendor-index.xml","/CP073203_VMw.zip/metadata.zip","/CP073203_VMw.zip/vib20/CP073203/HPE_bootbank_CP073203_HPD4.1-8.0.0.20613240.vib","/CP073203_VMw.zip/metadata.zip/vendor-index.xml","/CP073203_VMw.zip/metadata.zip/vmware.xml","/CP073203_VMw.zip/metadata.zip/vibs/CP073203-3937339721884900184.xml","/CP073203_VMw.zip/metadata.zip/bulletins/Smart-Component-CP073203_HPD4.1-8.0.0.20613240.xml"],"Name":"CP073203.zip","SHA1Sum":"ddbf1a1d46afbd1aaa370cc2119b810a50b6177c","SHA256Sum":"23771d3e1222e9567e1c19539465ebf165e4946b4f72f0b1890a58625e2b3deb","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP073203","Version":"HPD4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB006000JWKGN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0af87ab9169b49eca58f36b3a2","SupportedDevices":["4d2340a5-3042-3630-3030-304a574b474e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE  SN1700E 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900368","Version":"14.4.731.21"},{"DeviceName":"HPE  SN1700E 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F40015900367","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900214","Version":"14.4.731.21"},{"DeviceName":"HPE SN1200E 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900213","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900202","Version":"14.4.731.21"},{"DeviceName":"HPE SN1600E 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//B14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-E30015900201","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D5","Version":"14.4.731.21"},{"DeviceName":"HPE SN1610E 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"elxflashStandalone-windows-14.4.731.21-1//firmware//P14473121.grp","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-10DF-F400159002D6","Version":"14.4.731.21"}]},"Files":[{"Checksum":[{"Filename":"cp071322.exe","SHA1Sum":"94ccdf5231323f34e86d5c766e1cd93783a9e0ad","SHA256Sum":"1e30444871324d166c9d0565d3e9864c8dffea413921996956eb8f2d3d8f9609","SHA512Sum":"44f51e9decd1a370feb1bd741feef25a518d769b1ea5adffc1b7e0cb6a2a0211735b10cb38d648ce411360da600a9aa5f72ca8bfd6111fbf34a39c9c3c11aafc"}],"ComponentSizeInKB":4505,"CompsigList":["cp071322.compsig"],"FileList":["cp071322.xml","cpqsetup.exe","elxflashStandalone-windows-14.4.731.21-1/firmware/","elxflashStandalone-windows-14.4.731.21-1/firmware/B14473121.grp","elxflashStandalone-windows-14.4.731.21-1/firmware/P14473121.grp","elxflashStandalone-windows-14.4.731.21-1/win/","elxflashStandalone-windows-14.4.731.21-1/win/elxflash.bat","elxflashStandalone-windows-14.4.731.21-1/win/winlpcfg.bat","elxflashStandalone-windows-14.4.731.21-1/win/x64/","elxflashStandalone-windows-14.4.731.21-1/win/x64/elxflash.exe","elxflashStandalone-windows-14.4.731.21-1/win/x64/ElxLpCfgSvcMsg.dll","elxflashStandalone-windows-14.4.731.21-1/win/x64/libdfc.dll","elxflashStandalone-windows-14.4.731.21-1/win/x64/readme.txt","elxflashStandalone-windows-14.4.731.21-1/win/x64/RM.INI","elxflashStandalone-windows-14.4.731.21-1/win/x64/WinLpCfg.exe","fwmatrix.txt","elxflashStandalone-windows-14.4.731.21-1/win/x64/fwmatrix.txt","hpe_fw_matrix.xml","installer.dll","payload.json","readme.txt","reference.xml"],"Name":"cp071322.exe","SHA1Sum":"94ccdf5231323f34e86d5c766e1cd93783a9e0ad","SHA256Sum":"1e30444871324d166c9d0565d3e9864c8dffea413921996956eb8f2d3d8f9609","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-10DF-F40015900368","a6b1a447-382a-5a4f-10DF-F40015900367","a6b1a447-382a-5a4f-10DF-E30015900214","a6b1a447-382a-5a4f-10DF-E30015900213","a6b1a447-382a-5a4f-10DF-E30015900202","a6b1a447-382a-5a4f-10DF-E30015900201","a6b1a447-382a-5a4f-10DF-F400159002D5","a6b1a447-382a-5a4f-10DF-F400159002D6"],"TypeOfChange":"1","Version":"2026.06.01"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE Firmware Flash for Emulex Fibre Channel Host Bus Adapters for Microsoft Windows Server 2022 x64","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"emulex","SWKeyExpectedPath":"firmware:emulex"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aea906ca0bf04368b611496846","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":8,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071877.exe","SHA1Sum":"759677e3840571bd9ebf3fbe6ac652409f9f151a","SHA256Sum":"12d2cd64c423ee32699b2686487a292f7b1e22b504dc4795ba6fa43cfd77958c","SHA512Sum":"6d3ec9125276a54edda677a7c039f509aa1e0ac29570ca7eb18a3f257edd2a1a29916602df5a4dab908f88b8934d78445c14a8fdf94b299e3dceeb545033e26e"}],"ComponentSizeInKB":231058,"CompsigList":["cp071877_part1.compsig","cp071877_part2.compsig","cp071877_part3.compsig","cp071877_part4.compsig","cp071877_part5.compsig","cp071877_part6.compsig","cp071877_part7.compsig","cp071877_part8.compsig"],"FileList":["cp071877.xml","cpqsetup.exe","MlnxDriverInstaller.dll","MLNX_WinOF2-25_4_50020_All_x64.exe"],"Name":"cp071877.exe","SHA1Sum":"759677e3840571bd9ebf3fbe6ac652409f9f151a","SHA256Sum":"12d2cd64c423ee32699b2686487a292f7b1e22b504dc4795ba6fa43cfd77958c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"25.4.50020.0"}],"InstallationDependency":{},"Name":"HPE Mellanox OFED Storage Driver for Microsoft Windows Server x64- 2019/2022/2025","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_602639d355fd43f18b42a7d4d7","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101d1590037d","a6b1a447-382a-5a4f-15b3-101f159003fe"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","A42","U46","A43","U50","HPE Apollo 2000 Gen10 Plus System","U54","U54","U58","U58","U63","U57","A55","A55","A56","A56","U59","U58","U68","U68","U68","U71","HPE ProLiant DL380m Gen12","U71","U72","U77","U72","A42","A43","A43","A47","A48","U50","U47","A46","U47","A42","U54"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070316.exe","SHA1Sum":"2d19d349ce138b4890a64d5a36f391db707c957c","SHA256Sum":"56535fad8b725ccb4b1f2ee7a2c6cb6481d42f3b3bb5115ca7c9a11ef35491df","SHA512Sum":"b0f1ca3f98ded336caf37e75e752ac7a07c2cf2bb732cce5df9cb94cf686362959cf2e0ebb19bf4f06eadfbc4e74a9cf0fcde5281c226f2364aad8cafd0e1888"}],"ComponentSizeInKB":4199,"CompsigList":["cp070316.compsig"],"FileList":["cp070316.xml","cpqsetup.exe","elxdrvr-fc-14.4.624.1-1.exe","ElxStorInstaller.dll","install.xml","SysConfig.frm","SysConfig.frm.ja"],"Name":"cp070316.exe","SHA1Sum":"2d19d349ce138b4890a64d5a36f391db707c957c","SHA256Sum":"56535fad8b725ccb4b1f2ee7a2c6cb6481d42f3b3bb5115ca7c9a11ef35491df","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec0b6caafd"],"TypeOfChange":"1","Version":"14.4.624.1"}],"InstallationDependency":{},"Name":"HPE Storage Fibre Channel Adapter Kit for the x64 Emulex Storport Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"elxfc.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f2905e806184e86b5f2fb646d","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398"]},{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE e910 QSFP+ 4x10G Network Riser","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Backplane_4x10G_NCSI_4p30_80001A42.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37ce80860000","Version":"1.2684"},{"DeviceName":"HPE e910 1G RJ45 Network Rsr","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37d180860000","Version":"1.2684"},{"DeviceName":"HPE e910 2p 10GbE SFP+ Mod","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001A81.bin","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-37d380860000","Version":"1.2684"}]},"Files":[{"Checksum":[{"Filename":"firmware-e910-intel-nic-fw-pack-4.30-3.1.x86_64.rpm","SHA1Sum":"dd204678c30030b9031131c7753c7b52ae96b2c6","SHA256Sum":"b6fa70206bed81ce8c0fbfac87d90f2a12cd6fd9b8177fad6aef42d3fb877695","SHA512Sum":"498a2e77029ad03af131cab7e67f68f6527c78d3d8a634604b37b4f74afbea3eaebe3bfa0d3addc976e44518b0146c2e68a3d6efc5b0acb984b620ee3c1a695a"}],"ComponentSizeInKB":10740,"CompsigList":["firmware-e910-intel-nic-fw-pack-4.30-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/CP070830.xml","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/Immediate_offset_1.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/Immediate_offset_2.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/LBG_B2_Backplane_4x10G_NCSI_4p30_80001FC8.bin","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/LBG_B2_Hybrid_PHY_Auto_Detect_P01_Backplane_P23_NCSI_4p30_80001FE8.bin","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/OCP_Configuration.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/QSFP.cfg","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/RJ45.cfg","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/SFP.cfg","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/file_license.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/iSCSI.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/ilorest_chif.so","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/iv.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/nvmupdate64e","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/payload_version.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/setup","./usr/lib/x86_64-linux-gnu/firmware-e910-intel-nic-fw-pack-4.30-3.1/version.txt","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070830.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070830.scexe"],"Name":"firmware-e910-intel-nic-fw-pack-4.30-3.1.x86_64.rpm","SHA1Sum":"dd204678c30030b9031131c7753c7b52ae96b2c6","SHA256Sum":"b6fa70206bed81ce8c0fbfac87d90f2a12cd6fd9b8177fad6aef42d3fb877695","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-37ce80860000","a6b1a447-382a-5a4f-8086-37d180860000","a6b1a447-382a-5a4f-8086-37d380860000"],"TypeOfChange":"1","Version":"4.30"}],"InstallationDependency":{},"Name":"HPE Edgeline X722 NIC Firmware Component for Linux","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"x722","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e91293c3aac24e39a113870b38","SupportedDevices":["a6b1a447-382a-5a4f-8086-37D380860000","a6b1a447-382a-5a4f-8086-37CE80860000","a6b1a447-382a-5a4f-8086-37D180860000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","8.0","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","H10","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"i40e-kmp-default-2.30.18_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"b4d2bee4ff7aaa16d034dba0b210a00cc1f61b82","SHA256Sum":"610eb9868ffcc1b8b7ef0e7e9c3f324d8d36380e7c05ea99fe60ca342b726370","SHA512Sum":"e90c9c2f139460da71c775aea977f803eaa397ee5b4ea2157353d43136582b6b9b5ef0061d82011f7cfa56bebd0550c7a414f2b004f9f4501b823cd93f1811c5"}],"ComponentSizeInKB":523,"CompsigList":["i40e-kmp-default-2.30.18_k6.12.0_160000.5-1.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default/updates/i40e.ko","./usr/share/doc/packages/i40e-kmp-default","./usr/share/doc/packages/i40e-kmp-default/COPYING","./usr/share/doc/packages/i40e-kmp-default/README","./usr/share/man/man7/i40e.7.gz","./usr/share/pci.ids.d/pci.ids.i40e-kmp-2.30.18","./usr/share/smartupdate/i40e-kmp-default/component.xml"],"Name":"i40e-kmp-default-2.30.18_k6.12.0_160000.5-1.sles16sp0.x86_64.rpm","SHA1Sum":"b4d2bee4ff7aaa16d034dba0b210a00cc1f61b82","SHA256Sum":"610eb9868ffcc1b8b7ef0e7e9c3f324d8d36380e7c05ea99fe60ca342b726370","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecdb806fec"],"TypeOfChange":"1","Version":"2.30.18-1"}],"InstallationDependency":{},"Name":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"i40e-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9e5d113f369d4063ac5c8a582b","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072319.zip","SHA1Sum":"a2661dc8fc0df9899be746d85ef5a9684d80e539","SHA256Sum":"95a0d9bcfd5d5c492e63403aee9b4c7a132ae57b7682bec96fbd1890ef63e0fa","SHA512Sum":"8f28e4eae41cba2ed75ac799259cfe7ec2c67bd1086bc1e99687121ad7e1133027744409dcc9050fc2a43476fb8ba891e8d1216a7f343ec4f1ad268d4d6b329e"}],"ComponentSizeInKB":245,"CompsigList":["cp072319.compsig"],"FileList":["/cp072319.xml","/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.zip","/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.zip/index.xml","/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.zip/vendor-index.xml","/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.zip/metadata.zip","/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.zip/vib20/ixgben/INT_bootbank_ixgben_1.24.1.0-1OEM.800.1.0.20613240.vib","/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/vibs/ixgben--6474922224991532011.xml","/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.zip/metadata.zip/bulletins/Intel-ixgben_1.24.1.0-1OEM.800.1.0.20613240.xml"],"Name":"cp072319.zip","SHA1Sum":"a2661dc8fc0df9899be746d85ef5a9684d80e539","SHA256Sum":"95a0d9bcfd5d5c492e63403aee9b4c7a132ae57b7682bec96fbd1890ef63e0fa","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"ixgben","Version":"1.24.1.0-1OEM.800.1.0.20613240"}]}],"InstallationDependency":{},"Name":"HPE Intel ixgben Driver for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-ixgben:1.24.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.24.1.0-1OEM.800.1.0.20613240","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5301b07e98884c60aacbc69fa3","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U39","U45","U37","U38","U38","02020001","03020101","A66","A66","U77","03020102","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_5p0_PLDMoMCTP_80021BCC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"5.00"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_CQDA2_5p0_PLDMoMCTP_80021BCC.fwpkg","SHA1Sum":"a4f4bed2c78c3574ef9cb2076c52674a898ab32d","SHA256Sum":"7b3f4847b8e85e8b0a74e1a856716ed1bfa818dd8ce8c91ab814454caede509d","SHA512Sum":"b2160cb0e9d9a7398d93008213aa0f4a004e106196ddb23ff8aa692bfc3f6413bc8b45524f96b8f583b9bb3e849962c1a8b07995ec6f7e9f24c8c6592323991b"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_CQDA2_5p0_PLDMoMCTP_80021BCC.HPb","HPE_E810_CQDA2_5p0_PLDMoMCTP_80021BCC.xml","payload.json"],"Name":"HPE_E810_CQDA2_5p0_PLDMoMCTP_80021BCC.fwpkg","SHA1Sum":"a4f4bed2c78c3574ef9cb2076c52674a898ab32d","SHA256Sum":"7b3f4847b8e85e8b0a74e1a856716ed1bfa818dd8ce8c91ab814454caede509d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860002"],"TypeOfChange":"1","Version":"5.00"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_aeed4f126d34433ca6e32b2725","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Files":[{"Checksum":[{"Filename":"firmware-d8000_0130-3.1_amd64.deb","SHA1Sum":"97d6f3ebe308326199818bdcea2405245e29bc89","SHA256Sum":"c869381e842ee45183ad0cdb0d836b6f4393da6c7e7c91b3b9577720ffc88a50","SHA512Sum":"440a3c93ec1b91b1322a8663b11f38843e1c317597523e12aa573d676682dc0cdc0f24ee189a82e1f68bbb8d7f7cb55e27a6cdcc84fb279a7d40c507efd5b854"}],"ComponentSizeInKB":2743,"CompsigList":["firmware-d8000_0130-3.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/CP072188.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/Config.xml","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/ccissflash","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072188.scexe","./usr/lib/x86_64-linux-gnu/firmware-d8000-0130-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072188.scexe"],"Name":"firmware-d8000_0130-3.1_amd64.deb","SHA1Sum":"97d6f3ebe308326199818bdcea2405245e29bc89","SHA256Sum":"c869381e842ee45183ad0cdb0d836b6f4393da6c7e7c91b3b9577720ffc88a50","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Ubuntu (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2f1f7cbc92924ddfb1e1f05b01","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-238.1.165.0.sles15sp6.x86_64.rpm","SHA1Sum":"51c4cd97fc6072a078ee316ae7bb4e2194c3bd7d","SHA256Sum":"1e68b7d1a9fc1e52e7884111744c0ba6c4ff59edb2ab196092918093f0e331af","SHA512Sum":"3be2658e044d92a7cc4fd42b2df3b8a815913ba31f3e19b2d1320d9023e88d123d464de599f5241e23b6f5f5109fe9d0c09cbaead38ed7794fce91fdcee44d09"}],"ComponentSizeInKB":1259,"CompsigList":["bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-238.1.165.0.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/bnxt_en.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150600.21-238.1.165.0.sles15sp6.x86_64.rpm","SHA1Sum":"51c4cd97fc6072a078ee316ae7bb4e2194c3bd7d","SHA256Sum":"1e68b7d1a9fc1e52e7884111744c0ba6c4ff59edb2ab196092918093f0e331af","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-238.1.165.0"},{"Checksum":[{"Filename":"bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-238.1.165.0.sles15sp7.x86_64.rpm","SHA1Sum":"bff9e721893213cbb26b09a5e4b591d92fb617be","SHA256Sum":"327e2d8cea9b33daf355deac4bff3d8b667b524d205c58da176667ff8e91255b","SHA512Sum":"ff7a3fd27452efc9b9882863a9fdc88833354933645ab3f59300471f64d66ef6f0bb43b844f7c38cd1cfc519fdd36ec2aec8c5d76f528822b1a0bdf73616dc08"}],"ComponentSizeInKB":1274,"CompsigList":["bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-238.1.165.0.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/bnxt_en.ko","./lib/modules/6.4.0-150700.51-default/updates/drivers","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150700.51-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/bnxt_en-kmp-default/component.xml"],"Name":"bnxt_en-kmp-default-1.10.3_k6.4.0_150700.51-238.1.165.0.sles15sp7.x86_64.rpm","SHA1Sum":"bff9e721893213cbb26b09a5e4b591d92fb617be","SHA256Sum":"327e2d8cea9b33daf355deac4bff3d8b667b524d205c58da176667ff8e91255b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece34fd967"],"TypeOfChange":"1","Version":"1.10.3-238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"bnxt_en-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a765554e2bd44d77a694c5bed2","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-22811590036A","Version":"02.11.14"},{"DeviceName":"HPE SN1700Q 64Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-228115900369","Version":"02.11.14"},{"DeviceName":"HPE SN1100Q 16Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000FA","Version":"02.05.02"},{"DeviceName":"HPE SN1100Q 16Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2261159000F9","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900204","Version":"02.05.02"},{"DeviceName":"HPE SN1600Q 32Gb Single Port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//bk020502.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-226115900203","Version":"02.05.02"},{"DeviceName":"HPE SN1610Q 32Gb 1-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D3","Version":"02.11.14"},{"DeviceName":"HPE SN1610Q 32Gb 2-port Fibre Channel Host Bus Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//Flash//mh021114.bin","InstallDurationSec":180,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-2281159002D4","Version":"02.11.14"}]},"Files":[{"Checksum":[{"Filename":"CP072108.zip","SHA1Sum":"c725823b2fd4dfee784bad6f7005e32ab86574cc","SHA256Sum":"8eabb4e5e7af2f01e197fabe413469e81a07bb05c1badd173827619f73fac0aa","SHA512Sum":"fbb8570d0dbdd4859391b9a59961a669e077ae089af6e1eeb4bd5dafafb31473595bf15f2618710a5c6183d1be65316ff8e655b9142cda598f423d7332ea5e24"}],"ComponentSizeInKB":6735,"CompsigList":["CP072108.compsig"],"FileList":["/CP072108_BUILD_1.data","/CP072108.vmexe","/CP072108.vmexe64","/CP072108.vmfile","/CP072108_VMw.zip","/CP072108.xml","/payload.json","/CP072108_VMw.zip/index.xml","/CP072108_VMw.zip/vendor-index.xml","/CP072108_VMw.zip/metadata.zip","/CP072108_VMw.zip/vib20/CP072108/HPE_bootbank_CP072108_CP072108.1-1OEM.900.0.24755229.vib","/CP072108_VMw.zip/metadata.zip/vendor-index.xml","/CP072108_VMw.zip/metadata.zip/vmware.xml","/CP072108_VMw.zip/metadata.zip/vibs/CP072108-7189677174352235414.xml","/CP072108_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072108_CP072108.1-1OEM.900.0.24755229.xml"],"Name":"CP072108.zip","SHA1Sum":"c725823b2fd4dfee784bad6f7005e32ab86574cc","SHA256Sum":"8eabb4e5e7af2f01e197fabe413469e81a07bb05c1badd173827619f73fac0aa","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-22811590036A","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000FA","a6b1a447-382a-5a4f-1077-2261159000F9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002D3","a6b1a447-382a-5a4f-1077-2281159002D4"],"TypeOfChange":"1","Version":"2026.06.02","VibList":[{"Name":"CP072108","Version":"CP072108.1-1OEM.900.0.24755229"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"For Gen10/Gen11 server HPE QLogic Fibre Channel Enablement Kit version 6.0.0.1-3 or greater is required and should be already active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf362cdc1","SWKey":"HPE-CNA-FC-hpeqlgc-Enablement-Kit","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.0.1-3"}]}]}]},"Name":"HPE Firmware Flash for QLogic Fibre Channel Host Bus Adapters for VMware vSphere 9.0 and vSphere 9.1","PackageFormat":"","PerDeviceInstallTimeSeconds":180,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC","SWKeyExpectedPath":"firmware:QLOGIC"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0d29858b67b842d2be05d144c5","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB002000JYDNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a59444e45","Version":"HPD6"},{"DeviceName":"MB004000JYDPB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPNSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a59445042","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d4be2aecbb-HPD6-2.1.x86_64.rpm","SHA1Sum":"0fe891cd8ec3ab3541428f295dba8efe4ddcd890","SHA256Sum":"bb1d89ecdb98ff30bbb9d01d827d8ed627ac1434ca33b12f944e1f0586b33211","SHA512Sum":"05320c64adb103dc7bb411d560b0ca857e9d07af0ca95e6f238c0b45b4aa763fef58185d992b5b0833c1a9997159ef20cdf92442cce632d85b50935d3b6d5504"}],"ComponentSizeInKB":6225,"CompsigList":["firmware-hdd-d4be2aecbb-HPD6-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/CP068837.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/SCIMARBPNSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d4be2aecbb-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068837.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068837.scexe"],"Name":"firmware-hdd-d4be2aecbb-HPD6-2.1.x86_64.rpm","SHA1Sum":"0fe891cd8ec3ab3541428f295dba8efe4ddcd890","SHA256Sum":"bb1d89ecdb98ff30bbb9d01d827d8ed627ac1434ca33b12f944e1f0586b33211","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3230-3030-304a59444e45","4d2340a5-3042-3430-3030-304a59445042"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB002000JYDNE and MB004000JYDPB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000JYDNE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB004000JYDPB","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c975c71029334580b2c010de25","SupportedDevices":["4d2340a5-3042-3430-3030-304a59445042","4d2340a5-3042-3230-3030-304a59444e45"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWWQH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304757575148","Version":"HPG6"},{"DeviceName":"MB002000GWWQF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304757575146","Version":"HPG6"},{"DeviceName":"MB001000GWWQE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNTG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3130-3030-304757575145","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"cp068665.exe","SHA1Sum":"d3be0c01e65dc927094aa1636f10a305bf2955c3","SHA256Sum":"a1f701b315e51a52dc98ac6a12896b580329ed4fc5d6e430b5533ccc9d12e63a","SHA512Sum":"d1f6fb61f86ec998c7a457799defa1ee0d3bae29110ea1d6b5c4a884804e3c4ff37d32d1acd8f425e7a1e85c73b33ffd4f97365fbf1961abab11f983bb2acf96"}],"ComponentSizeInKB":3817,"CompsigList":["cp068665.compsig"],"FileList":["cp068665.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARRNNTG6.rel","setup.dll"],"Name":"cp068665.exe","SHA1Sum":"d3be0c01e65dc927094aa1636f10a305bf2955c3","SHA256Sum":"a1f701b315e51a52dc98ac6a12896b580329ed4fc5d6e430b5533ccc9d12e63a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWWQH, MB002000GWWQF and MB001000GWWQE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWWQH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB002000GWWQF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB001000GWWQE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dd4d0089d26745a78f0c891836","SupportedDevices":["4d2340a5-3042-3430-3030-304757575148","4d2340a5-3042-3230-3030-304757575146","4d2340a5-3042-3130-3030-304757575145"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JYDKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444b4b","Version":"HPD6"},{"DeviceName":"MB012000JYCJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a59434a46","Version":"HPD6"},{"DeviceName":"MB014000JYCJV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a59434a56","Version":"HPD6"},{"DeviceName":"MB016000JYDKL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a59444b4c","Version":"HPD6"},{"DeviceName":"MB018000JYDKN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPSD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59444b4e","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8173816d98-HPD6-3.1.x86_64.rpm","SHA1Sum":"260cf2a3959d61cec6498d499d1382d889522436","SHA256Sum":"3db0946d793f8aa938f3a7d7a88b95b4f5f5ea92a9944e5efd0fe3566e58d84a","SHA512Sum":"461db09ccb156859373b626d4848c8423c64fa33ca054b03e10804f740a338cf8c7e77df4d08e1aa51f4e4808162ea774fd738a743f5684bd9b61685010ebaa0"}],"ComponentSizeInKB":6085,"CompsigList":["firmware-hdd-8173816d98-HPD6-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/CP068839.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/SHPEEVSBPSD6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8173816d98-HPD6-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068839.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068839.scexe"],"Name":"firmware-hdd-8173816d98-HPD6-3.1.x86_64.rpm","SHA1Sum":"260cf2a3959d61cec6498d499d1382d889522436","SHA256Sum":"3db0946d793f8aa938f3a7d7a88b95b4f5f5ea92a9944e5efd0fe3566e58d84a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JYDKK, MB012000JYCJF, MB014000JYCJV, MB016000JYDKL and MB018000JYDKN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JYDKK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JYCJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JYCJV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JYDKL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYDKN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f94eb54b3b1c4a1da2fcfa19d0","SupportedDevices":["4d2340a5-3042-3031-3030-304a59444b4b","4d2340a5-3042-3231-3030-304a59434a46","4d2340a5-3042-3431-3030-304a59434a56","4d2340a5-3042-3631-3030-304a59444b4c","4d2340a5-3042-3831-3030-304a59444b4e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0","10.0","9.0","8.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL6WBA0HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"cp073210.exe","SHA1Sum":"11addea7629bacba8e9862f9d2a2b46269b0c917","SHA256Sum":"af7d0681ce0aa12664dc2d6a9543535d2e46cd414df9a30da4ad7eb7ee0ace8d","SHA512Sum":"d05889c19208200bec109dc2561c68a21e354a13b809d5b252dcd2ff9f4704f12c0f99abe5609da402771040ae2603a70e046878d30eb04421ee2aeb85458f39"}],"ComponentSizeInKB":4479,"CompsigList":["cp073210.compsig"],"FileList":["cp073210.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WVL6WBA0HPG5.rel"],"Name":"cp073210.exe","SHA1Sum":"11addea7629bacba8e9862f9d2a2b46269b0c917","SHA256Sum":"af7d0681ce0aa12664dc2d6a9543535d2e46cd414df9a30da4ad7eb7ee0ace8d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWKGR Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3005453cfb4d4cbd948e462bc2","SupportedDevices":["4d2340a5-3042-3630-3030-3047574b4752"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069543.exe","SHA1Sum":"e3e7158f66b761de3030515bda1e395d2eec726a","SHA256Sum":"aa058d4640fa160118c21c3decef95630c268cbc3195faddbbdbd91b78e38a49","SHA512Sum":"196070481eef7d115676dc2ed26a4eeb8ea10c73f8bbe19a70872a3bd8cce4ffb4d509a20af94e8371230ecd08ee985f10495ca490871eaef8082dc254c75d56"}],"ComponentSizeInKB":1057,"CompsigList":["cp069543.compsig"],"FileList":["cp069543.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069543.exe","SHA1Sum":"e3e7158f66b761de3030515bda1e395d2eec726a","SHA256Sum":"aa058d4640fa160118c21c3decef95630c268cbc3195faddbbdbd91b78e38a49","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"TypeOfChange":"1","Version":"14.0.7.0"}],"InstallationDependency":{},"Name":"Intel i350 Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4a14deaf10d5470da0e2b4e08f","SupportedDevices":["a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","H08","H08","H10","H10","H10","A42","U56","U61","U60","HPE Edgeline EL8000t Converged Edge System","HPE Edgeline EL8000 Converged Edge System","H09","U54","U54","U54","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070565.exe","SHA1Sum":"936a366abeeb954a748caec075c4786581b11907","SHA256Sum":"c6a57d0640561c8df1aa58fa3487183fa46c84848552e9269cd13ff4acffa1d0","SHA512Sum":"452e949c5764918db5cb376c67774dbf1f3654b36c82dd4f04abd87ee48d9d2dfcb5735e91403fa60f8161509a7f265026352cc35658728002f64b9d8ab330f0"}],"ComponentSizeInKB":835,"CompsigList":["cp070565.compsig"],"FileList":["cp070565.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll","vxs.cat","vxs.inf","vxs.sys","vxsmsg.dll"],"Name":"cp070565.exe","SHA1Sum":"936a366abeeb954a748caec075c4786581b11907","SHA256Sum":"c6a57d0640561c8df1aa58fa3487183fa46c84848552e9269cd13ff4acffa1d0","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1bb72727"],"TypeOfChange":"1","Version":"2.3.7.0"}],"InstallationDependency":{},"Name":"HPE Intel vxs Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"vxs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\vxs.inf_amd64_d6120d6ae1cc028c"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_78f8d72267e84dd0a155067114","SupportedDevices":["a6b1a447-382a-5a4f-8086-1565159000d1","a6b1a447-382a-5a4f-8086-1565159000d2"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VS000480KXALB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3438-304b58414c42","Version":"85032G00"},{"DeviceName":"VS000960KWXFN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3030-3936-304b5758464e","Version":"85032G00"},{"DeviceName":"VS001920KWXFP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3130-3932-304b57584650","Version":"85032G00"},{"DeviceName":"VS003840KWXFQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"85032G00_mp.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-3053-3330-3834-304b57584651","Version":"85032G00"}]},"Files":[{"Checksum":[{"Filename":"cp068635.exe","SHA1Sum":"67c0aa3a220eb6be0a1c8147f0241eb7bd03bd71","SHA256Sum":"63890f44054a00c797e7601b60fb5d74bd72a4e5bdf90408ef3adad7ae14d8b8","SHA512Sum":"7639017b42b61b080fde0a05b5911adc5f5c114c2cd47fff0324a05a49cbac4a5b58e97201ead65484b76f329663f7bcc85eddb7519816684134a76a82d846ba"}],"ComponentSizeInKB":5676,"CompsigList":["cp068635.compsig"],"FileList":["85032G00_mp.bin","cp068635.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068635.exe","SHA1Sum":"67c0aa3a220eb6be0a1c8147f0241eb7bd03bd71","SHA256Sum":"63890f44054a00c797e7601b60fb5d74bd72a4e5bdf90408ef3adad7ae14d8b8","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3030-3936-304b5758464e","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3330-3834-304b57584651"],"TypeOfChange":"1","Version":"85032G00"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - VS000480KXALB, VS003840KWXFQ, VS001920KWXFP and VS000960KWXFN drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VS000480KXALB","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS000960KWXFN","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS001920KWXFP","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VS003840KWXFQ","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2209d7eaa57a4b1d8bc6228741","SupportedDevices":["562340a5-3053-3030-3438-304b58414c42","562340a5-3053-3330-3834-304b57584651","562340a5-3053-3130-3932-304b57584650","562340a5-3053-3030-3936-304b5758464e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A42_4.04_04_02_2026.fwpkg","SHA1Sum":"2369c9dbad0b2101310797f035db3daef96b39d0","SHA256Sum":"70d7f0a2f6a481c650000cb4c160736712a689f1a05dddfe345b604175a95cce","SHA512Sum":"ea7de6fdb4fa6d05e020e65962784c0000f37a4f08de5cd19d59d133bdb022a9059cb993d28fd46a9d496eaaae08edcaaa1b003f0aa14d0151c21bd40c8fd24e"}],"ComponentSizeInKB":32818,"CompsigList":[],"FileList":["A42_4.04_04_02_2026.signed.flash","A42_4.04_04_02_2026.xml","payload.json"],"Name":"A42_4.04_04_02_2026.fwpkg","SHA1Sum":"2369c9dbad0b2101310797f035db3daef96b39d0","SHA256Sum":"70d7f0a2f6a481c650000cb4c160736712a689f1a05dddfe345b604175a95cce","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_58ffaedc5e374be8b114e80a14","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A42","A42"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"CP070981.zip","SHA1Sum":"73c07e56d48c34f581a379af16add1ae7ab8ece3","SHA256Sum":"a5253d078991e41e9101735fd4703915dbb64283a608eecae2ca8a61a06a6653","SHA512Sum":"575ccd05cd8f67139ed2d715cb5b41d5ca73d981de6d940af092822eb9e181934af857702c28be29c8f241dc6d2138f7ba6c7065c113b8c97bd223ac44de04d3"}],"ComponentSizeInKB":19840,"CompsigList":["CP070981.compsig"],"FileList":["/CP070981_BUILD_1.data","/CP070981.vmexe64","/CP070981.vmfile","/CP070981_VMw.zip","/CP070981.xml","/payload.json","/CP070981_VMw.zip/index.xml","/CP070981_VMw.zip/vendor-index.xml","/CP070981_VMw.zip/metadata.zip","/CP070981_VMw.zip/vib20/CP070981/HPE_bootbank_CP070981_HPD4.1-8.0.0.20613240.vib","/CP070981_VMw.zip/metadata.zip/vendor-index.xml","/CP070981_VMw.zip/metadata.zip/vmware.xml","/CP070981_VMw.zip/metadata.zip/vibs/CP070981--7102409209499076412.xml","/CP070981_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070981_HPD4.1-8.0.0.20613240.xml"],"Name":"CP070981.zip","SHA1Sum":"73c07e56d48c34f581a379af16add1ae7ab8ece3","SHA256Sum":"a5253d078991e41e9101735fd4703915dbb64283a608eecae2ca8a61a06a6653","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4","VibList":[{"Name":"CP070981","Version":"HPD4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c832462f234d48aa80ae236838","SupportedDevices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3631-3030-304a575a4845","4d2340a5-3042-3431-3030-304a575a4843"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-elx-lpfc-14.4.731.20-1.rhel10u1.x86_64.rpm","SHA1Sum":"a35f5bf969002e094272bc3133e66a33af4a2423","SHA256Sum":"c49aac23478d053ec768b4ed4dfbb4958ba88ddbd8a12670c0cbfbfc153b4d61","SHA512Sum":"3242a67bfb4cf844d696b4c3b602718a3a1630c0fcbd3bb4652270ba0b5f31b4e79cd1e18c29f965b4cc7d3778ec72c2adca5d6dec98eea966a1ca630d7ce049"}],"ComponentSizeInKB":839,"CompsigList":["kmod-elx-lpfc-14.4.731.20-1.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/lpfc.conf","./etc/dracut.conf.d/lpfc.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/elx-lpfc","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/elx-lpfc/lpfc.ko","./usr/share/smartupdate/kmod-elx-lpfc/component.xml"],"Name":"kmod-elx-lpfc-14.4.731.20-1.rhel10u1.x86_64.rpm","SHA1Sum":"a35f5bf969002e094272bc3133e66a33af4a2423","SHA256Sum":"c49aac23478d053ec768b4ed4dfbb4958ba88ddbd8a12670c0cbfbfc153b4d61","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec82edf83b"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 10 Server Update 1 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-elx-lpfc","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f598604f92cb4cc68abc0f6807","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5748504b","Version":"HPD9"},{"DeviceName":"EH000600JWHPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXe0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57485048","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"cp068760.exe","SHA1Sum":"5a4ee195be282872096af18bbed29f8d53eea0a2","SHA256Sum":"d4d7060a9f483f2a3f5950e781ff0ae29d0ee6d01e9175d2ee166b369c3988c5","SHA512Sum":"e5e9f10955d4310ae52f45d3bb1b7d691c41c5aa1641c3d3d61a9a2acf3b1474fe0cf0597c16d089cd05812e52a78ec01c6236ac887291163f474fbda8c719e4"}],"ComponentSizeInKB":3173,"CompsigList":["cp068760.compsig"],"FileList":["cp068760.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA14SXe0HPD9.REL"],"Name":"cp068760.exe","SHA1Sum":"5a4ee195be282872096af18bbed29f8d53eea0a2","SHA256Sum":"d4d7060a9f483f2a3f5950e781ff0ae29d0ee6d01e9175d2ee166b369c3988c5","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5748504b","452340a5-3048-3030-3630-304a57485048"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EH000900JWHPK and EH000600JWHPH  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6747a7568d794cf59f59ca86ec","SupportedDevices":["452340a5-3048-3030-3630-304a57485048","452340a5-3048-3030-3930-304a5748504b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component","FirmwareImages":[{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false},{"DelayAfterInstallSec":180,"DirectFlashOK":false,"FileName":"93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","InstallDurationSec":720,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1857b65875","Version":"0130"}]},"Files":[{"Checksum":[{"Filename":"cp072203.exe","SHA1Sum":"8835a6853449f93e42a230f007dda8efd2f2c33b","SHA256Sum":"118d94b30b10478d4425139b0fae4e07077eb217a313d1c5919630f6f8d8ab50","SHA512Sum":"27015cd84e50f1c21d85419f9f21a224754116ed1d6b39fb1eeb090cfb21a4c41b90bee0c0593572d2c7f0bc76c6bcf09278a5627426afc19da0ef047d431c76"}],"ComponentSizeInKB":14876,"CompsigList":["cp072203.compsig"],"FileList":["93-00001181_hpe_cffebod_dual_path_combined_fw_inband_r2021.51.4.gff","93-00007488_hpe_cffebod_single_path_combined_fw_inband_r2021.51.4.gff","Config.xml","cp072203.xml","cpqsetup.exe","Microsoft.VC90.CRT.manifest","msvcp110.dll","msvcp90.dll","msvcr110.dll","msvcr90.dll","payload.json","VDUFlash.dll"],"Name":"cp072203.exe","SHA1Sum":"8835a6853449f93e42a230f007dda8efd2f2c33b","SHA256Sum":"118d94b30b10478d4425139b0fae4e07077eb217a313d1c5919630f6f8d8ab50","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1857b65875"],"TypeOfChange":"1","Version":"0130"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"HPE D8000 12Gb SAS Disk Enclosure ROM Flash Component for Windows (x64)","PackageFormat":"","PerDeviceInstallTimeSeconds":1200,"RebootRequired":"no","SWKeys":[{"Name":"D8000","SWKeyExpectedPath":"firmware:sd:disk_enclosure"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3a8a00d6438540cbb1ccbdb143","SupportedDevices":["b99dfb74-f0bc-464f-b418-cd1857b65875","b99dfb74-f0bc-464f-b418-cd1857b65875"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]},{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","U40","U39","U47","U45","U37","U47","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","A42","U61","U60"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GWSXF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-304757535846","Version":"HPG4"},{"DeviceName":"VK000960GWSXH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-304757535848","Version":"HPG4"},{"DeviceName":"VK001920GWSXK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475753584b","Version":"HPG4"},{"DeviceName":"MK000480GWUGF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3438-304757554746","Version":"HPG4"},{"DeviceName":"MK000960GWUGH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3030-3936-304757554748","Version":"HPG4"},{"DeviceName":"MK001920GWUGK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52002TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304b-3130-3932-30475755474b","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"CP072402.zip","SHA1Sum":"27af254da905678e631b402d8cf6871021ec30fe","SHA256Sum":"c4cc99fa8d819df5c6d09c99978e9dafbf9b887b3b9c321b92b21579c505325e","SHA512Sum":"3885fdb64cd6bca25b03709bbc4f7273d0fa02c4cc7c4bf473ac1c2c38ba27fce2de464e77cee59ac7fa2146920e16e2621a1de9c574b0dc7689e89a7e48b94c"}],"ComponentSizeInKB":17944,"CompsigList":["CP072402.compsig"],"FileList":["/CP072402_BUILD_1.data","/CP072402.vmexe64","/CP072402.vmfile","/CP072402_VMw.zip","/CP072402.xml","/payload.json","/CP072402_VMw.zip/index.xml","/CP072402_VMw.zip/vendor-index.xml","/CP072402_VMw.zip/metadata.zip","/CP072402_VMw.zip/vib20/CP072402/HPE_bootbank_CP072402_HPG4.1-8.0.0.20613240.vib","/CP072402_VMw.zip/metadata.zip/vendor-index.xml","/CP072402_VMw.zip/metadata.zip/vmware.xml","/CP072402_VMw.zip/metadata.zip/vibs/CP072402--5173219045973136071.xml","/CP072402_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072402_HPG4.1-8.0.0.20613240.xml"],"Name":"CP072402.zip","SHA1Sum":"27af254da905678e631b402d8cf6871021ec30fe","SHA256Sum":"c4cc99fa8d819df5c6d09c99978e9dafbf9b887b3b9c321b92b21579c505325e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["562340a5-304b-3030-3438-304757535846","562340a5-304b-3030-3936-304757535848","562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3030-3438-304757554746","4d2340a5-304b-3030-3936-304757554748","4d2340a5-304b-3130-3932-30475755474b"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP072402","Version":"HPG4.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - VK000480GWSXF, VK000960GWSXH, VK001920GWSXK, MK000480GWUGF, MK000960GWUGH and MK001920GWUGK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GWSXF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GWSXH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GWSXK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000480GWUGF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK000960GWUGH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MK001920GWUGK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a38d26f85b2a4a5baae2625e4c","SupportedDevices":["562340a5-304b-3130-3932-30475753584b","4d2340a5-304b-3130-3932-30475755474b","562340a5-304b-3030-3936-304757535848","4d2340a5-304b-3030-3936-304757554748","562340a5-304b-3030-3438-304757535846","4d2340a5-304b-3030-3438-304757554746"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.70 (08/19/2026)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u34-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"672c784f4b25508038e12679b637d0526e085d97","SHA256Sum":"eecc2e0d17ee842dae4ea6454dc5cfa4fbecff1b1a254d9c96a9a0697261020f","SHA512Sum":"4e9d502af579f246ee677a4a31eedbab0470938b5a3a05aec0dea260e034e270a121f48fcd5a42b836c5658abcf65e4c48ad3c38c22652bff862da7b83aae97c"}],"ComponentSizeInKB":11654,"CompsigList":["firmware-system-u34-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.70_2026_08_19-1.1/CP073153.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.70_2026_08_19-1.1/U34_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u34-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073153.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073153.scexe"],"Name":"firmware-system-u34-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"672c784f4b25508038e12679b637d0526e085d97","SHA256Sum":"eecc2e0d17ee842dae4ea6454dc5cfa4fbecff1b1a254d9c96a9a0697261020f","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_088e9fdb33374e1b80c912f526","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","6.0","11.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mft-4.36.0-147.rhel9u8.x86_64.rpm","SHA1Sum":"a56e2472eea6cfa86c93499d4be6ea91fc63ce43","SHA256Sum":"6d6dab0947d8d8f4c4cebaf6162e9e247ddb51a6960a956de7bc5299e0a42f15","SHA512Sum":"dd02e21feaec80812f47857059877b486c809ebb658f38f64696a1050435c7b4a0abf54d0f81ece80ba62c8b1ecc3f3c1de7b263f939c626948a9f77ff7a4eba"}],"ComponentSizeInKB":29832,"CompsigList":["mft-4.36.0-147.rhel9u8.x86_64.compsig"],"FileList":["./etc/mft/RPMS/mft","./etc/mft/mft.conf","./etc/mft/mst.conf","./usr/bin/dimax_init","./usr/bin/flint","./usr/bin/flint_ext","./usr/bin/generate_pgcb_commands","./usr/bin/mcra","./usr/bin/mdevices_info","./usr/bin/mft-shell","./usr/bin/mft_shell_cedar","./usr/bin/mft_uninstall.sh","./usr/bin/minit","./usr/bin/mlxcableimgen","./usr/bin/mlxdpa","./usr/bin/mlxfwreset","./usr/bin/mlxfwstress","./usr/bin/mlxfwstress_ext","./usr/bin/mlxgearbox","./usr/bin/mlxpci","./usr/bin/mlxprivhost","./usr/bin/mlxptrace","./usr/bin/mlxptrace_ext","./usr/bin/mlxtokengenerator","./usr/bin/mlxtokengenerator_ext","./usr/bin/mst","./usr/bin/mst_aggregate","./usr/bin/mst_cable","./usr/bin/mst_ib_add","./usr/bin/mst_retimer","./usr/bin/mst_tool","./usr/bin/mstop","./usr/bin/ndc_tool","./usr/bin/nvjtag_discovery","./usr/bin/nvml_discovery","./usr/bin/resourcedump","./usr/bin/resourceparse","./usr/bin/rm_driver_discovery","./usr/bin/stedump","./usr/bin/sysfs_module_com","./usr/lib/.build-id","./usr/lib/.build-id/08","./usr/lib/.build-id/08/927629ed71d86047c1dd8b6eaf57dcc98b990a","./usr/lib/.build-id/0c","./usr/lib/.build-id/0c/f0ed148f8fe52345a6a8a7020d2f5b6dcc8082","./usr/lib/.build-id/11","./usr/lib/.build-id/11/45f40aee1207692c13b5d3f81f14e608c6ac5a","./usr/lib/.build-id/19","./usr/lib/.build-id/19/b56bfff4855e5782efddc80495af80a82a23c4","./usr/lib/.build-id/24","./usr/lib/.build-id/24/10ba0fa644176f747fb58a65ab62074a8e1ef7","./usr/lib/.build-id/27","./usr/lib/.build-id/27/3f53315ba733de29581deb13a13a0dbd0f9210","./usr/lib/.build-id/3a","./usr/lib/.build-id/3a/0dec761d5a4486d4ff59b898e8b7f056872ad0","./usr/lib/.build-id/3a/13fe203665bca3fab7fa4a5d161f022ef76dcc","./usr/lib/.build-id/3c","./usr/lib/.build-id/3c/3ecd6c6ca3a49b275e70b2642f3fc3fae64248","./usr/lib/.build-id/3f","./usr/lib/.build-id/3f/88882dd9df68a201eb2f1a148ab57a3896f6ae","./usr/lib/.build-id/44","./usr/lib/.build-id/44/abf55ea1615d32987b347dd0159fea55f65a1a","./usr/lib/.build-id/58","./usr/lib/.build-id/58/dd4ca90d4727cf2b487e2d69927435f13f9092","./usr/lib/.build-id/66","./usr/lib/.build-id/66/7885d870a23c6a79ddd8829d4d1d66c14e4d12","./usr/lib/.build-id/67","./usr/lib/.build-id/67/45523f0d1a021a298fa64895fd751d9af30b33","./usr/lib/.build-id/70","./usr/lib/.build-id/70/bb26c38d18e3c4dbd475d9d34b9e9e58d1be02","./usr/lib/.build-id/75","./usr/lib/.build-id/75/6c92e59a736ef7ad9c4f028040c3fdfeaf4cee","./usr/lib/.build-id/77","./usr/lib/.build-id/77/7f1d9c72fb14f6832694d620db980a52b0768b","./usr/lib/.build-id/79","./usr/lib/.build-id/79/ed84d3e53c5e144d16a415e478d17ce765bb53","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/fc7869f4208956831d0c77adf0f6d0f5871e2e","./usr/lib/.build-id/80","./usr/lib/.build-id/80/b3326272897b31df700e534842c1a55e1131e8","./usr/lib/.build-id/86","./usr/lib/.build-id/86/97283969707044ab9024dea1ae1faa8a97f0f9","./usr/lib/.build-id/87","./usr/lib/.build-id/87/e2ef537474640486b37edd6c1c14962427a87a","./usr/lib/.build-id/8c","./usr/lib/.build-id/8c/250ff2d61eec0fff17680bf9b1b8c9eb7eeca2","./usr/lib/.build-id/96","./usr/lib/.build-id/96/ecba2ad33bf4d3c8af9383a30b51fa65fbcfd6","./usr/lib/.build-id/a1","./usr/lib/.build-id/a1/c25c9400c503e0ed70d14f11c98a70518dfdf9","./usr/lib/.build-id/b0","./usr/lib/.build-id/b0/aa9919256956d56149f5323b9a6ae2cfee5f4f","./usr/lib/.build-id/b1","./usr/lib/.build-id/b1/bd5b8094f997a021d76fd2ddce88674fa01d90","./usr/lib/.build-id/bb","./usr/lib/.build-id/bb/8734c14bb6a67ce4a34dfbdb776e74f0558f0f","./usr/lib/.build-id/c8","./usr/lib/.build-id/c8/724ffc652dcad57df024011f26e578a4ae2dbf","./usr/lib/.build-id/cc","./usr/lib/.build-id/cc/33483cca0abb1744a59a46793d4f47f58d23ca","./usr/lib/.build-id/d1","./usr/lib/.build-id/d1/f98645eb65a37865f1c5769a4b661493857b7b","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/cb9ddcc75e049b56599862bc2a22b4310b7099","./usr/lib/.build-id/d8","./usr/lib/.build-id/d8/e17ea2a196b200a6fc118f47ff1c63f5b86547","./usr/lib/.build-id/e1","./usr/lib/.build-id/e1/789f5ec1052c504e84ec72f4e55f8e54dbffc4","./usr/lib/.build-id/e1/de06e776afbe2d88b61e16057f5db9bde12f6a","./usr/lib/.build-id/e3","./usr/lib/.build-id/e3/05adf0415cd2708ab12e0649cff9e1d26303f2","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/d648a51fa94e76c61e9fb6cc3958c880bd5b18","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/fa01b6f52e423ad0bb3141d3672f2cdd17a54a","./usr/lib/.build-id/fb","./usr/lib/.build-id/fb/dde236c8762bd5e934eed5e19c502f3cf87738","./usr/lib/.build-id/fe","./usr/lib/.build-id/fe/54edb79bdf267ad6e9c5759bf109e419e3d41a","./usr/lib64/mft/bash_libs/tools_version.sh","./usr/lib64/mft/libcmdif_ibdump.a","./usr/lib64/mft/libmemaccess.a","./usr/lib64/mft/libmft.so","./usr/lib64/mft/libmtcr.a","./usr/lib64/mft/libmtcr_ul.a","./usr/lib64/mft/mtcr_plugins/mcables.so","./usr/lib64/mft/mtcr_plugins/ssh_utility.so","./usr/lib64/mft/python_tools/c_dev_mgt.so","./usr/lib64/mft/python_tools/ccmdif.so","./usr/lib64/mft/python_tools/cmdif.py","./usr/lib64/mft/python_tools/cmtcr.so","./usr/lib64/mft/python_tools/dev_mgt.py","./usr/lib64/mft/python_tools/device_info.so","./usr/lib64/mft/python_tools/device_info_wrapper.py","./usr/lib64/mft/python_tools/device_properties_api.py","./usr/lib64/mft/python_tools/gearbox/abir_add_devices.py","./usr/lib64/mft/python_tools/gearbox/add_gearbox_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_add_devices.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_reset_script.py","./usr/lib64/mft/python_tools/gearbox/amos_gb_sw_mux_config.py","./usr/lib64/mft/python_tools/gearbox/buffalo_fui.py","./usr/lib64/mft/python_tools/gearbox/gearbox_lc_control_reset.py","./usr/lib64/mft/python_tools/gearbox/gearbox_remove_script.py","./usr/lib64/mft/python_tools/gearbox/gearbox_status_script.py","./usr/lib64/mft/python_tools/generate_pgcb_commands.py","./usr/lib64/mft/python_tools/generated/device_properties_data.py","./usr/lib64/mft/python_tools/mft_logger.py","./usr/lib64/mft/python_tools/mlx_mfa_gen.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwreset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/__init__.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mcam.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mfrl.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mpcir.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mroq.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/cmd_reg_mrsi.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/drivers_safety_check.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/hot_reset.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/logger.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mcra.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlnx_peripheral_components.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_mlnxdriver.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_status_checker.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/mlxfwreset_utils.py","./usr/lib64/mft/python_tools/mlxfwreset/mlxfwresetlib/pci_device.py","./usr/lib64/mft/python_tools/mlxpci/binary_file.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci.py","./usr/lib64/mft/python_tools/mlxpci/mlxpci_lib.py","./usr/lib64/mft/python_tools/mlxprivhost/mlxprivhost.py","./usr/lib64/mft/python_tools/mlxste/__init__.py","./usr/lib64/mft/python_tools/mlxste/api.py","./usr/lib64/mft/python_tools/mlxste/argtypes.py","./usr/lib64/mft/python_tools/mlxste/constants.py","./usr/lib64/mft/python_tools/mlxste/crawler.py","./usr/lib64/mft/python_tools/mlxste/dmlib.py","./usr/lib64/mft/python_tools/mlxste/dumpers/__init__.py","./usr/lib64/mft/python_tools/mlxste/dumpers/dumper.py","./usr/lib64/mft/python_tools/mlxste/dumpers/pcap.py","./usr/lib64/mft/python_tools/mlxste/dumpers/raw.py","./usr/lib64/mft/python_tools/mlxste/errors.py","./usr/lib64/mft/python_tools/mlxste/factory.py","./usr/lib64/mft/python_tools/mlxste/loaders/__init__.py","./usr/lib64/mft/python_tools/mlxste/loaders/loader.py","./usr/lib64/mft/python_tools/mlxste/loaders/pcap.py","./usr/lib64/mft/python_tools/mlxste/loaders/raw.py","./usr/lib64/mft/python_tools/mlxste/packet.py","./usr/lib64/mft/python_tools/mlxste/parser.py","./usr/lib64/mft/python_tools/mlxste/providers/__init__.py","./usr/lib64/mft/python_tools/mlxste/providers/provider.py","./usr/lib64/mft/python_tools/mlxste/providers/resourcedump_provider.py","./usr/lib64/mft/python_tools/mlxste/stedump.py","./usr/lib64/mft/python_tools/mlxste/stelib.py","./usr/lib64/mft/python_tools/mlxste/stetypes.py","./usr/lib64/mft/python_tools/mst_aggregate/mst_aggregate.py","./usr/lib64/mft/python_tools/mst_cable/mst_cable.py","./usr/lib64/mft/python_tools/mst_ib_add/mst_ib_add.py","./usr/lib64/mft/python_tools/mst_retimer/mst_retimer.py","./usr/lib64/mft/python_tools/mst_vmdl/mst_vmdl.py","./usr/lib64/mft/python_tools/mtcr.py","./usr/lib64/mft/python_tools/nvjtag/GB100_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/SDDV_Jtag.py","./usr/lib64/mft/python_tools/nvjtag/jtag.py","./usr/lib64/mft/python_tools/regaccess.py","./usr/lib64/mft/python_tools/regaccess_hca_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_retimer_ext_structs.py","./usr/lib64/mft/python_tools/regaccess_switch_ext_structs.py","./usr/lib64/mft/python_tools/rreg_access.so","./usr/lib64/mft/python_tools/stelib.so","./usr/lib64/mft/python_tools/sysfs_module_com/sysfs_module_com.py","./usr/lib64/mft/python_tools/tools_version.py","./usr/share/man/man1/flint.1.gz","./usr/share/man/man1/mcra.1.gz","./usr/share/man/man1/mdevices_info.1.gz","./usr/share/man/man1/minit.1.gz","./usr/share/man/man1/mlxfwreset.1.gz","./usr/share/man/man1/mst.1.gz","./usr/share/man/man1/mstop.1.gz","./usr/share/mft/fw_stress_db/stress_types.db","./usr/share/mft/fw_stress_db/stress_types_ext.db","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.adb","./usr/share/mft/prm_dbs/gpu/ext/register_access_table.dat","./usr/share/mft/prm_dbs/hca/ext/hca_cap_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.adb","./usr/share/mft/prm_dbs/hca/ext/register_access_table.dat","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.adb","./usr/share/mft/prm_dbs/retimers/ext/register_access_table.dat","./usr/share/mft/prm_dbs/switch/ext/register_access_table.adb","./usr/share/mft/prm_dbs/switch/ext/register_access_table.dat","./usr/share/mft/remote/remote.json","./usr/share/smartupdate/mft/component.xml"],"Name":"mft-4.36.0-147.rhel9u8.x86_64.rpm","SHA1Sum":"a56e2472eea6cfa86c93499d4be6ea91fc63ce43","SHA256Sum":"6d6dab0947d8d8f4c4cebaf6162e9e247ddb51a6960a956de7bc5299e0a42f15","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"TypeOfChange":"0","Version":"4.36"},{"Checksum":[{"Filename":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel9u8.x86_64.rpm","SHA1Sum":"a5ddc63bf9c40f6326b11552657f5b14bef9f1e9","SHA256Sum":"68bda2373c6d1e784dabf740bbc271b386c461ac6ff962b4dc284f32e9f8d556","SHA512Sum":"2d7a6193efa199f0c438350b314c9d3279e9048f4237232c4ae97aefeea7a2c9b62a52df4608fb5ebc98c35f81f2c88089fc8ed2f45aa845ecd8d10ccb2717a9"}],"ComponentSizeInKB":76,"CompsigList":["kmod-kernel-mft-mlnx-4.36.0-147.1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/kernel-mft-mlnx-mst_pci.conf","./etc/depmod.d/kernel-mft-mlnx-mst_pciconf.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/kernel-mft-mlnx","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/kernel-mft-mlnx/mst_pci.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/kernel-mft-mlnx/mst_pciconf.ko","./usr/lib/.build-id","./usr/lib/.build-id/60","./usr/lib/.build-id/60/8120f7b7a50e0441f39f8e4ac3475dd2a34c36","./usr/lib/.build-id/73","./usr/lib/.build-id/73/25d12f483e395acc8cc66a98b963b8fac4eba9","./usr/share/smartupdate/kmod-kernel-mft-mlnx/component.xml"],"Name":"kmod-kernel-mft-mlnx-4.36.0-147.1.rhel9u8.x86_64.rpm","SHA1Sum":"a5ddc63bf9c40f6326b11552657f5b14bef9f1e9","SHA256Sum":"68bda2373c6d1e784dabf740bbc271b386c461ac6ff962b4dc284f32e9f8d556","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","20a6e8e4-bf33-4c71-a6bf-d9ecca403118"],"TypeOfChange":"0","Version":"4.36"}],"InstallationDependency":{},"Name":"HPE Mellanox MFT prerequisite RPMs for Mellanox adapter firmware update in Secure Boot mode for Red Hat Enterprise Linux 9 Update 8 (x86_64)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"},{"Name":"mft","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-kernel-mft-mlnx","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cd6ebccd3f7f4a6085f626ebdd","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-102115b30237"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U50","U47","U45","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","HPE Apollo 2000 Gen10 Plus System","A42","U56","U61","02020001","03020101","03030201"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069517.exe","SHA1Sum":"4a75724a1d957874f5c6a78f9fe72d90061406e3","SHA256Sum":"bc2dcd0cea62dcb64ddff2f0411dffe73bd632cbc640d04c170f7f219666ec0e","SHA512Sum":"4aea0679efdcf7a5d802d7512362975d0b9209d3ba663fce4c0b0f57dbd7d7799676bb5a4de869c081123517b1919e406173143d1f392b5d15b2b73edc7aaff3"}],"ComponentSizeInKB":1058,"CompsigList":["cp069517.compsig"],"FileList":["cp069517.xml","cpqsetup.exe","cp_data.xml","e1r68x64.cat","e1r68x64.din","e1r68x64.inf","e1r68x64.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069517.exe","SHA1Sum":"4a75724a1d957874f5c6a78f9fe72d90061406e3","SHA256Sum":"bc2dcd0cea62dcb64ddff2f0411dffe73bd632cbc640d04c170f7f219666ec0e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecfbeb7312"],"TypeOfChange":"1","Version":"14.0.7.0"}],"InstallationDependency":{},"Name":"HPE Intel E1R Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_03c3b9c44d5a47e2909fe84d5f","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB018000GXMTK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-3047584d544b","Version":"HPG3"},{"DeviceName":"MB020000GXMTQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SLONGSPKETG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3032-3030-3047584d5451","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"CP070972.zip","SHA1Sum":"7617d00f94f3721d9fcba842905eea5c2a43ec5b","SHA256Sum":"45c95ba05e3c7e0d91384f9106b4958e7f95ee33440489afbfab55a5f56a75bc","SHA512Sum":"f3abad70db83458bb62d392836ce2db7e8bbca25808f76dc04931a65be0b74fce6a730e607a511bbd99ead34b3662665b643dc50d97a39fe732566f9d3e2dd85"}],"ComponentSizeInKB":19237,"CompsigList":["CP070972.compsig"],"FileList":["/CP070972_BUILD_1.data","/CP070972.vmexe64","/CP070972.vmfile","/CP070972_VMw.zip","/CP070972.xml","/payload.json","/CP070972_VMw.zip/index.xml","/CP070972_VMw.zip/vendor-index.xml","/CP070972_VMw.zip/metadata.zip","/CP070972_VMw.zip/vib20/CP070972/HPE_bootbank_CP070972_HPG3.1-8.0.0.20613240.vib","/CP070972_VMw.zip/metadata.zip/vendor-index.xml","/CP070972_VMw.zip/metadata.zip/vmware.xml","/CP070972_VMw.zip/metadata.zip/vibs/CP070972--2412359239000523884.xml","/CP070972_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070972_HPG3.1-8.0.0.20613240.xml"],"Name":"CP070972.zip","SHA1Sum":"7617d00f94f3721d9fcba842905eea5c2a43ec5b","SHA256Sum":"45c95ba05e3c7e0d91384f9106b4958e7f95ee33440489afbfab55a5f56a75bc","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3831-3030-3047584d544b","4d2340a5-3042-3032-3030-3047584d5451"],"TypeOfChange":"1","Version":"HPG3","VibList":[{"Name":"CP070972","Version":"HPG3.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi  - MB018000GXMTK and MB020000GXMTQ Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB018000GXMTK","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB020000GXMTQ","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_df98f6a135dd46aa8f95ecb57b","SupportedDevices":["4d2340a5-3042-3032-3030-3047584d5451","4d2340a5-3042-3831-3030-3047584d544b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U33","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U33_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000020b","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u33-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"96fd5d17b32aec93c75dc837f4134e535876c575","SHA256Sum":"a9db2964c30b377e81955b0a8066de8195002048fbc34d7c316757504e549886","SHA512Sum":"b1aab9a98df08df21ccc55da41ed0a33a0c132481cca67854616871dadac0c1b3a3e6849714fa2d29473bf5fdd003e5a0d10b1ab34e2820d7c1064227ed517ee"}],"ComponentSizeInKB":11238,"CompsigList":["firmware-system-u33-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.70_2026_08_19-1.1/CP073149.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.70_2026_08_19-1.1/U33_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u33-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073149.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073149.scexe"],"Name":"firmware-system-u33-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"96fd5d17b32aec93c75dc837f4134e535876c575","SHA256Sum":"a9db2964c30b377e81955b0a8066de8195002048fbc34d7c316757504e549886","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020b"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant ML110 Gen10 (U33) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U33","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ee51f78c110e4177bfd6a44dae","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","11.0","7.0","6.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U33"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069552.exe","SHA1Sum":"fafbd4ffb6ca9a8fa45b272464ff14deccae10ed","SHA256Sum":"6cadac092a76e7c6682cab3433a98577aa493690f2208143d93eb1884be7b837","SHA512Sum":"90066452fd6c3cc1f87c3a65253856e37a1edef940d6f628e2792fbf88cc6e750fbb78d22145235499a1a05afd2dbc5ab13536858bdcfdc8efb5608ba375003f"}],"ComponentSizeInKB":1016,"CompsigList":["cp069552.compsig"],"FileList":["cp069552.xml","cpqsetup.exe","cp_data.xml","install.xml","ixs.cat","ixs.inf","ixs.sys","ixsmsg.dll","nicdrvr.dll"],"Name":"cp069552.exe","SHA1Sum":"fafbd4ffb6ca9a8fa45b272464ff14deccae10ed","SHA256Sum":"6cadac092a76e7c6682cab3433a98577aa493690f2208143d93eb1884be7b837","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec3fbd656b"],"TypeOfChange":"1","Version":"4.2.7.0"}],"InstallationDependency":{},"Name":"HPE Intel ixs Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"ixs.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\ixs.inf_amd64_166a1f78fe537c55"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3116ddb609f54ed5ab42139bfa","SupportedDevices":["a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG001800JWJNR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a574a4e52","Version":"HPDB"},{"DeviceName":"EG002400JWJNT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a574a4e54","Version":"HPDB"},{"DeviceName":"EG002400MXJQT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304d584a5154","Version":"HPDB"},{"DeviceName":"EG001800JXLWB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3830-304a584c5742","Version":"HPDB"},{"DeviceName":"EG002400JXLWC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SSKYBT512EDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3230-3430-304a584c5743","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"CP070933.zip","SHA1Sum":"c1cbdd428ff50ce7f688de63b9604aa6c5bef4ac","SHA256Sum":"f4beb7b2d3171a61275a7e418007cc5567791ebb37368706f551a92bb75ed658","SHA512Sum":"e9fb0c58e42ff40abef088a1d9a20ee328d92ed80abf1c20c7facc9377af713a224f432fbc507555e5e5baca553599bfe804e3dac28d459c12de7528ef0b7c85"}],"ComponentSizeInKB":20114,"CompsigList":["CP070933.compsig"],"FileList":["/CP070933_BUILD_6.data","/CP070933.vmexe64","/CP070933.vmfile","/CP070933_VMw.zip","/CP070933.xml","/payload.json","/CP070933_VMw.zip/index.xml","/CP070933_VMw.zip/vendor-index.xml","/CP070933_VMw.zip/metadata.zip","/CP070933_VMw.zip/vib20/CP070933/HPE_bootbank_CP070933_HPDB.6-8.0.0.20613240.vib","/CP070933_VMw.zip/metadata.zip/vendor-index.xml","/CP070933_VMw.zip/metadata.zip/vmware.xml","/CP070933_VMw.zip/metadata.zip/vibs/CP070933-1033139981878007841.xml","/CP070933_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070933_HPDB.6-8.0.0.20613240.xml"],"Name":"CP070933.zip","SHA1Sum":"c1cbdd428ff50ce7f688de63b9604aa6c5bef4ac","SHA256Sum":"f4beb7b2d3171a61275a7e418007cc5567791ebb37368706f551a92bb75ed658","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"TypeOfChange":"1","Version":"HPDB","VibList":[{"Name":"CP070933","Version":"HPDB.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - EG001800JWJNR, EG002400JWJNT, EG001800JXLWB, EG002400JXLWC and EG002400MXJQT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG001800JWJNR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JWJNT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400MXJQT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001800JXLWB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG002400JXLWC","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e43213c0ddde4f4ea1e04d9faa","SupportedDevices":["452340a5-3047-3130-3830-304a574a4e52","452340a5-3047-3230-3430-304a574a4e54","452340a5-3047-3230-3430-304d584a5154","452340a5-3047-3130-3830-304a584c5742","452340a5-3047-3230-3430-304a584c5743"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"238.1.169000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"238.1.169000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"238.1.169000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"238.1.169000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"238.1.169000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"238.1.169000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"238.1.169000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"238.1.169000"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-nxe_1.27.0-1.1_amd64.deb","SHA1Sum":"75eefa2b1fb77a8dda9f231ebcc0609893c115ac","SHA256Sum":"c6dde2165dc70c395d44decc5998b7e2d0dfe1195270f6c2c47d4b25ec7bc58e","SHA512Sum":"c9c5058f2137c7c1b6299c148be4e20efbc9c47189762de34c685bbbb75ba6129ed4541489e34e3a2f03245e276729f423596044ff8017b16201d6824ac74d19"}],"ComponentSizeInKB":1397,"CompsigList":["firmware-nic-bcm-nxe_1.27.0-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/CP072709.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/CP072709.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072709.scexe","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-1.27.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072709.scexe"],"Name":"firmware-nic-bcm-nxe_1.27.0-1.1_amd64.deb","SHA1Sum":"75eefa2b1fb77a8dda9f231ebcc0609893c115ac","SHA256Sum":"c6dde2165dc70c395d44decc5998b7e2d0dfe1195270f6c2c47d4b25ec7bc58e","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E"],"TypeOfChange":"1","Version":"1.27.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for deb Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4b59793f2d52447099f3ad05b6","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04"]}],"SupportedPlatforms":true,"SupportedProducts":["A40","A41","02020001","03020101","03030201","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Files":[{"Checksum":[{"Filename":"cp068657.exe","SHA1Sum":"b6b07de380f82f0c822493a1fab3e60ba2c5a826","SHA256Sum":"5174318587325cc3f333e1fbc5a0275c40cd1ec18b1d26a04a7e1594fd96c943","SHA512Sum":"f36096bd92156aafdb79258c196acc54747ef29adaa0a0a75b51a233c30d9db25bd75669bd33bd84b4ef13b2213fd01214705e41863f4c095f52b63ec83fcf11"}],"ComponentSizeInKB":4025,"CompsigList":["cp068657.compsig"],"FileList":["cp068657.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SKESTEDD.rel"],"Name":"cp068657.exe","SHA1Sum":"b6b07de380f82f0c822493a1fab3e60ba2c5a826","SHA256Sum":"5174318587325cc3f333e1fbc5a0275c40cd1ec18b1d26a04a7e1594fd96c943","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EH000600JWCPF and EH000900JWCPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_abfd69e9a7e643a8a89639344b","SupportedDevices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A48","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A48_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022f","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a48-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"3eea26b59910ab1f40d486f6c66a633826243efd","SHA256Sum":"bcf70bfadbee2c97adabb13912487dbde64405bd46b40951565f3e27f6a56586","SHA512Sum":"2203eafc4ac865d515f4838dfa3ffe78e5719e427b959c7b92f7f746f798e7b8c69f0f973f0b8f814b1e82c38ab7befcd9fd68cf0322ba47564662fe17adba80"}],"ComponentSizeInKB":33233,"CompsigList":["firmware-system-a48-4.04_2026_04_02-1.1.x86_64_part1.compsig","firmware-system-a48-4.04_2026_04_02-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/A48_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/CP071585.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a48-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071585.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071585.scexe"],"Name":"firmware-system-a48-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"3eea26b59910ab1f40d486f6c66a633826243efd","SHA256Sum":"bcf70bfadbee2c97adabb13912487dbde64405bd46b40951565f3e27f6a56586","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022f"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL645d Gen10 Plus (A48) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A48","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_14a6f633fe8647418d63619090","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","10.0","9.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000208","Version":"v3.70 (08/19/2026)"},{"DeviceName":"System BIOS - U31","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U31_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000209","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U31_3.70_08_19_2026.fwpkg","SHA1Sum":"1f06a14dd88b2e51d46affb237c0afb3a29aeb0e","SHA256Sum":"8f066496af8dfb207d40927e508349859e60fcd89e7e3ecd0d5ffa7550aed6f3","SHA512Sum":"ab11cb1753d5795e72054dfc46be04cc20f1cdf98f69ba8ea852208464d0cbd1e9931a275d6f843f00755ca6f4b08f43d8c7a293acfbcca21d0535e25dd97c00"}],"ComponentSizeInKB":32827,"CompsigList":[],"FileList":["payload.json","U31_3.70_08_19_2026.signed.flash","U31_3.70_08_19_2026.xml"],"Name":"U31_3.70_08_19_2026.fwpkg","SHA1Sum":"1f06a14dd88b2e51d46affb237c0afb3a29aeb0e","SHA256Sum":"8f066496af8dfb207d40927e508349859e60fcd89e7e3ecd0d5ffa7550aed6f3","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000208","00000000-0000-0000-0000-000000000209"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL160 Gen10/DL180 Gen10 (U31) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U31","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f838707ff6bb48e3ba9da49fb8","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U31","U31"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U43_3.76_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000218","Version":"v3.76 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"U43_3.76_05_28_2026.fwpkg","SHA1Sum":"8e4413954f8e94412c862409deca041153062ca0","SHA256Sum":"754c7c5cfe20d6c9ce3594b4cf7c22f96e02c2c5884df82c4d523cfd6d1889bb","SHA512Sum":"168c7dc795aa14cd41ebc7f9ecf4edfc51e04aebc23e5db69ae89eb4603c35a24bdadd88752e2e99144d2c0276d4f9eef6e9bdfa8f96bbb40c3d75a8c92b1b46"}],"ComponentSizeInKB":16429,"CompsigList":[],"FileList":["payload.json","U43_3.76_05_28_2026.signed.flash","U43_3.76_05_28_2026.xml"],"Name":"U43_3.76_05_28_2026.fwpkg","SHA1Sum":"8e4413954f8e94412c862409deca041153062ca0","SHA256Sum":"754c7c5cfe20d6c9ce3594b4cf7c22f96e02c2c5884df82c4d523cfd6d1889bb","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000218"],"TypeOfChange":"1","Version":"3.76_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL20 Gen10 (U43) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fa387ee286ad4f2bbf80de0f9f","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150600.21-OFED.26.04.0.8.6.1.1.sles15sp6.x86_64.rpm","SHA1Sum":"b1f870983196a7f4afc2e93ba97483bf7a493b2c","SHA256Sum":"e58a3003d00d470529ed7785b29f9697c2a6206f6f244918ad65636e44f637a4","SHA512Sum":"af592ba61ec2f81cb5eaa3528d67d6d41708acde795db027c907dd4debc60ffbebcaf504e703cb1cad06ee513cc3c084f80432f083fea1b7b432461b3f8580b4"}],"ComponentSizeInKB":2640,"CompsigList":["mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150600.21-OFED.26.04.0.8.6.1.1.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/compat","./lib/modules/6.4.0-150600.21-default/updates/compat/mlx_compat.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers","./lib/modules/6.4.0-150600.21-default/updates/drivers/block","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd/rnbd-client.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/block/rnbd/rnbd-server.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl/fwctl.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/fwctl/mlx5/mlx5_fwctl.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_ucm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_umad.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/ib_uverbs.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/iw_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/rdma_cm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/core/rdma_ucm.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/cxgb4","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/cxgb4/iw_cxgb4.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/efa","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/efa/efa.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/erdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/erdma/erdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/hfi1","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/hfi1/hfi1.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/irdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/irdma/irdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mana","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mana/mana_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx4","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx4/mlx4_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mlx5/mlx5_ib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mthca","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/mthca/ib_mthca.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/ocrdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/ocrdma/ocrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qedr","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qedr/qedr.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qib","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/qib/ib_qib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/usnic","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/usnic/usnic_verbs.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/vmw_pvrdma","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/hw/vmw_pvrdma/vmw_pvrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rdmavt","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rdmavt/rdmavt.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rxe","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/rxe/rdma_rxe.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/siw","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/sw/siw/siw.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/ipoib","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/ipoib/ib_ipoib.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/iser","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/iser/ib_iser.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/isert","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/isert/ib_isert.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/opa_vnic","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/opa_vnic/opa_vnic.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-client.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/rtrs/rtrs-server.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srp","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srp/ib_srp.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srpt","./lib/modules/6.4.0-150600.21-default/updates/drivers/infiniband/ulp/srpt/ib_srpt.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_core.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlx5/core/mlx5_dpll.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxfw","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxfw/mlxfw.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxsw","./lib/modules/6.4.0-150600.21-default/updates/drivers/net/ethernet/mellanox/mlxsw/mlxsw_spectrum.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/host","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/host/nvme-rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/target","./lib/modules/6.4.0-150600.21-default/updates/drivers/nvme/target/nvmet-rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/vdpa/mlx5/mlx5_vdpa.ko","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci/mlx5","./lib/modules/6.4.0-150600.21-default/updates/drivers/vfio/pci/mlx5/mlx5-vfio-pci.ko","./lib/modules/6.4.0-150600.21-default/updates/net","./lib/modules/6.4.0-150600.21-default/updates/net/9p","./lib/modules/6.4.0-150600.21-default/updates/net/9p/9pnet_rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/mlxdevm","./lib/modules/6.4.0-150600.21-default/updates/net/mlxdevm/mlxdevm.ko","./lib/modules/6.4.0-150600.21-default/updates/net/rds","./lib/modules/6.4.0-150600.21-default/updates/net/rds/rds_rdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/smc","./lib/modules/6.4.0-150600.21-default/updates/net/smc/smc.ko","./lib/modules/6.4.0-150600.21-default/updates/net/smc/smc_diag.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/rpcrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/svcrdma.ko","./lib/modules/6.4.0-150600.21-default/updates/net/sunrpc/xprtrdma/xprtrdma.ko","./usr/share/smartupdate/mlnx-ofa_kernel-kmp-default/component.xml"],"Name":"mlnx-ofa_kernel-kmp-default-26.04_k6.4.0_150600.21-OFED.26.04.0.8.6.1.1.sles15sp6.x86_64.rpm","SHA1Sum":"b1f870983196a7f4afc2e93ba97483bf7a493b2c","SHA256Sum":"e58a3003d00d470529ed7785b29f9697c2a6206f6f244918ad65636e44f637a4","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"},{"Checksum":[{"Filename":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp6.x86_64.rpm","SHA1Sum":"1f2080adde4e8ed6ecc2eab89377d2d45a550bd5","SHA256Sum":"e402e320efe5788cf96eb98e66d073aee69ff831b4675e96c029f5d0dcea12dd","SHA512Sum":"d82e698a8a57b222f4861edb3b9e98bb19d16da271336fd867a4b36aca1bdda87b6accaa8d85679306ab3c50f45e667b4e6c4742eb3c223fb16867343fc204d6"}],"ComponentSizeInKB":9993,"CompsigList":["mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp6.x86_64.compsig"],"FileList":["./bin/mlnx_conf_mgr.sh","./bin/mlnx_interface_mgr.sh","./etc/infiniband","./etc/infiniband/info","./etc/infiniband/mlx5.conf","./etc/infiniband/openib.conf","./etc/init.d/openibd","./etc/libibverbs.d","./etc/libibverbs.d/mlx5.driver","./etc/libvma.conf","./etc/mellanox/hugepages.d","./etc/modprobe.d/ib_ipoib.conf","./etc/modprobe.d/mlnx-bf.conf","./etc/modprobe.d/mlnx.conf","./etc/rdma","./etc/rdma/mlx4.conf","./etc/rdma/modules","./etc/rdma/modules/rdma.conf","./etc/systemd/system/mlnx_interface_mgr@.service","./lib/udev/auxdev-sf-netdev-rename","./lib/udev/mlnx_bf_udev","./lib/udev/rules.d/83-mlnx-sf-name.rules","./lib/udev/rules.d/90-ib.rules","./lib/udev/sf-rep-netdev-rename","./sbin/doca-hugepages","./sbin/mlnx-sf","./sbin/mlnx_bf_configure","./sbin/sysctl_perf_tuning","./usr/bin/ib_atomic_bw","./usr/bin/ib_atomic_lat","./usr/bin/ib_read_bw","./usr/bin/ib_read_lat","./usr/bin/ib_send_bw","./usr/bin/ib_send_lat","./usr/bin/ib_write_bw","./usr/bin/ib_write_lat","./usr/bin/mlnx_dump_parser","./usr/bin/mlnx_perf","./usr/bin/mlnx_qos","./usr/bin/mlx_fs_dump","./usr/bin/ofed_info","./usr/bin/ofed_rpm_info","./usr/bin/raw_ethernet_burst_lat","./usr/bin/raw_ethernet_bw","./usr/bin/raw_ethernet_fs_rate","./usr/bin/raw_ethernet_lat","./usr/bin/run_perftest_loopback","./usr/bin/run_perftest_multi_devices","./usr/bin/tc_wrap.py","./usr/lib/dracut","./usr/lib/dracut/modules.d","./usr/lib/dracut/modules.d/50rdma","./usr/lib/mlx4-setup.sh","./usr/lib/modprobe.d","./usr/lib/modprobe.d/libmlx4.conf","./usr/lib/systemd/system/openibd.service","./usr/lib/systemd/system/rdma-ndd.service","./usr/lib/systemd/system/vma.service","./usr/lib/udev/rdma_rename","./usr/lib/udev/rules.d","./usr/lib/udev/rules.d/60-rdma-ndd.rules","./usr/lib/udev/rules.d/60-rdma-persistent-naming.rules","./usr/lib/udev/rules.d/75-rdma-description.rules","./usr/lib/udev/rules.d/90-rdma-umad.rules","./usr/lib64/libefa.so.1","./usr/lib64/libefa.so.1.4.63.0","./usr/lib64/libibumad.so.3","./usr/lib64/libibumad.so.3.4.63.0","./usr/lib64/libibverbs","./usr/lib64/libibverbs.so.1","./usr/lib64/libibverbs.so.1.16.63.0","./usr/lib64/libibverbs/libmlx5-rdmav59.so","./usr/lib64/libmlx4.so.1","./usr/lib64/libmlx4.so.1.0.63.0","./usr/lib64/libmlx5.so.1","./usr/lib64/libmlx5.so.1.27.63.0","./usr/lib64/libperftest_kernels.so","./usr/lib64/librdmacm.so.1","./usr/lib64/librdmacm.so.1.4.63.0","./usr/lib64/libvma.so","./usr/lib64/libvma.so.9","./usr/lib64/libvma.so.9.8.84","./usr/lib64/rsocket","./usr/lib64/rsocket/librspreload.so","./usr/lib64/rsocket/librspreload.so.1","./usr/lib64/rsocket/librspreload.so.1.0.0","./usr/sbin/cma_roce_mode","./usr/sbin/cma_roce_tos","./usr/sbin/common_irq_affinity.sh","./usr/sbin/compat_gid_gen","./usr/sbin/ib2ib_setup","./usr/sbin/ibdev2netdev","./usr/sbin/mlnx_affinity","./usr/sbin/mlnx_tune","./usr/sbin/mlnxofedctl","./usr/sbin/ofed_uninstall.sh","./usr/sbin/rdma-ndd","./usr/sbin/rdma_topo","./usr/sbin/set_irq_affinity.sh","./usr/sbin/set_irq_affinity_bynode.sh","./usr/sbin/set_irq_affinity_cpulist.sh","./usr/sbin/setup_mr_cache.sh","./usr/sbin/show_counters","./usr/sbin/show_gids","./usr/sbin/show_irq_affinity.sh","./usr/sbin/show_irq_affinity_hints.sh","./usr/sbin/sysinfo-snapshot.py","./usr/sbin/vendor_post_uninstall.sh","./usr/sbin/vendor_pre_uninstall.sh","./usr/sbin/vmad","./usr/share/doc/packages/libibverbs","./usr/share/doc/packages/libibverbs/libibverbs.md","./usr/share/doc/packages/librdmacm","./usr/share/doc/packages/librdmacm/librdmacm.md","./usr/share/doc/packages/libvma-9.8.84","./usr/share/doc/packages/libvma-9.8.84/CHANGES","./usr/share/doc/packages/libvma-9.8.84/README","./usr/share/doc/packages/mlnx-ofa_kernel","./usr/share/doc/packages/mlnx-ofa_kernel/82-net-setup-link.rules","./usr/share/doc/packages/mlnx-ofa_kernel/vf-net-link-name.sh","./usr/share/doc/packages/mlnx-tools","./usr/share/doc/packages/mlnx-tools/ib2ib_setup.txt","./usr/share/doc/packages/perftest","./usr/share/doc/packages/perftest/COPYING","./usr/share/doc/packages/perftest/README","./usr/share/doc/packages/perftest/runme","./usr/share/doc/packages/rdma-core","./usr/share/doc/packages/rdma-core/70-persistent-ipoib.rules","./usr/share/doc/packages/rdma-core/README.md","./usr/share/doc/packages/rdma-core/tag_matching.md","./usr/share/doc/packages/rdma-core/udev.md","./usr/share/licenses/libvma","./usr/share/licenses/libvma/LICENSE","./usr/share/licenses/mlnx-tools","./usr/share/licenses/mlnx-tools/LICENSE","./usr/share/licenses/rdma-core","./usr/share/licenses/rdma-core/COPYING.BSD_FB","./usr/share/licenses/rdma-core/COPYING.BSD_MIT","./usr/share/licenses/rdma-core/COPYING.GPL2","./usr/share/licenses/rdma-core/COPYING.md","./usr/share/man/man1/ib_atomic_bw.1.gz","./usr/share/man/man1/ib_atomic_lat.1.gz","./usr/share/man/man1/ib_read_bw.1.gz","./usr/share/man/man1/ib_read_lat.1.gz","./usr/share/man/man1/ib_send_bw.1.gz","./usr/share/man/man1/ib_send_lat.1.gz","./usr/share/man/man1/ib_write_bw.1.gz","./usr/share/man/man1/ib_write_lat.1.gz","./usr/share/man/man1/perftest.1.gz","./usr/share/man/man1/raw_ethernet_burst_lat.1.gz","./usr/share/man/man1/raw_ethernet_bw.1.gz","./usr/share/man/man1/raw_ethernet_fs_rate.1.gz","./usr/share/man/man1/raw_ethernet_lat.1.gz","./usr/share/man/man7/rsocket.7.gz","./usr/share/man/man7/vma.7.gz","./usr/share/man/man8/ib2ib_setup.8.gz","./usr/share/man/man8/mlnxofedctl.8.gz","./usr/share/man/man8/rdma-ndd.8.gz","./usr/share/man/man8/vmad.8.gz","./usr/share/mlnx-tools/python/dcbnetlink.py","./usr/share/mlnx-tools/python/netlink.py","./usr/share/mlnx_ofed/mlnx_bf_assign_ct_cores.sh","./usr/share/mlnx_ofed/mlnx_drv_ctl","./usr/share/mlnx_ofed/mod_load_funcs","./usr/share/smartupdate/mlnx-ofa_kernel/component.xml"],"Name":"mlnx-ofa_kernel-26.04-OFED.26.04.0.8.6.1.sles15sp6.x86_64.rpm","SHA1Sum":"1f2080adde4e8ed6ecc2eab89377d2d45a550bd5","SHA256Sum":"e402e320efe5788cf96eb98e66d073aee69ff831b4675e96c029f5d0dcea12dd","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eceb667fe5","20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4"],"TypeOfChange":"1","Version":"26.04"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 11 SP4 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"11.4"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 12 SP3 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"12.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox RoCE Driver (SUSE LINUX Enterprise Server 15 SP0 AMD64/EM64T)","OSVersion":{"Name":"Linux","Value":"15.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd271bba4","SWKey":"mlnx-ofa_kernel","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"4.4"}]}]}]},"Name":"HPE Mellanox RoCE Driver [ConnectX-4 Lx and above] for SUSE LINUX Enterprise Server 15 SP6 (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"mlnx-ofa_kernel","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d91eaeb1ccfd4d6893d490bfb7","SupportedDevices":["a6b1a447-382a-5a4f-15b3-102115b30237","a6b1a447-382a-5a4f-15b3-102315b30002","a6b1a447-382a-5a4f-15b3-102315b30006","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-102115b30073","a6b1a447-382a-5a4f-15b3-102115b30086","a6b1a447-382a-5a4f-15b3-102115b30074","a6b1a447-382a-5a4f-15b3-102115b30085","a6b1a447-382a-5a4f-15b3-102115b30053","a6b1a447-382a-5a4f-15b3-1017159002c8","a6b1a447-382a-5a4f-15b3-10171590032d","a6b1a447-382a-5a4f-15b3-1015159002c9","a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-101715900346","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-1015159002c1","a6b1a447-382a-5a4f-15b3-1015159002c7","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282","a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b15b30068","a6b1a447-382a-5a4f-15b3-101b15900347","a6b1a447-382a-5a4f-15b3-101b15900345","a6b1a447-382a-5a4f-15b3-101b15900348","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b15b30069","a6b1a447-382a-5a4f-15b3-101b159002af","a6b1a447-382a-5a4f-15b3-101b15b30074","a6b1a447-382a-5a4f-15b3-101d15b30040"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U17","U34","A42","A40","U46","U30","P89","A42","U46","U32","P89","A43","A43","A43","A41","U31","U31","U36","U43","U41","A47","A48","U40","U21","U50","U47","U45","U25","U37","A46","U47","U38","U38","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","U46","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U68","U68","U68","U71","U69","U69","U66","U71","U72","A59","U72","U70","A66","A66","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HP Ethernet 1Gb 2-port 332i Adapter (22E8)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332i-2x1G-14E4-165F-103C-22E8.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C22E8","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 2-port 332T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//332T-2x1G-14E4-165F-103C-1786.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-165F103C1786","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331FLR-4x1G-14E4-1657-103C-169D.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C169D","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331T-4x1G-14E4-1657-103C-3383.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C3383","Version":"20.38.51"},{"DeviceName":"HP Ethernet 1Gb 4-port 331i Adapter (22BE)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//331i-4x1G-14E4-1657-103C-22BE.BIN","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-1657103C22BE","Version":"20.38.51"}]},"Files":[{"Checksum":[{"Filename":"CP072704.zip","SHA1Sum":"dc9ae699f0c0f797de126c3e6b6636cc4696a7df","SHA256Sum":"fb9c5d4dbeb82f151b9965f88e8ae51ea4f2703bec9a6c3abba0284014a7de5b","SHA512Sum":"73f8d48f0240624938e75e7dc28809665c5b6feec89959ea43e682afd9ed8418efb83ba043f51d394efcd13654131610d0cc8ab0febe96f9cf94a743f9f46b8f"}],"ComponentSizeInKB":17389,"CompsigList":["CP072704.compsig"],"FileList":["/CP072704_BUILD_1.data","/CP072704.vmexe64","/CP072704.vmfile","/CP072704_VMw.zip","/CP072704.xml","/payload.json","/CP072704_VMw.zip/index.xml","/CP072704_VMw.zip/vendor-index.xml","/CP072704_VMw.zip/metadata.zip","/CP072704_VMw.zip/vib20/CP072704/HPE_bootbank_CP072704_1.45.0.1-8.0.0.20613240.vib","/CP072704_VMw.zip/metadata.zip/vendor-index.xml","/CP072704_VMw.zip/metadata.zip/vmware.xml","/CP072704_VMw.zip/metadata.zip/vibs/CP072704-7488145385461482392.xml","/CP072704_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072704_1.45.0.1-8.0.0.20613240.xml"],"Name":"CP072704.zip","SHA1Sum":"dc9ae699f0c0f797de126c3e6b6636cc4696a7df","SHA256Sum":"fb9c5d4dbeb82f151b9965f88e8ae51ea4f2703bec9a6c3abba0284014a7de5b","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-165F103C22E8","a6b1a447-382a-5a4f-14E4-165F103C1786","a6b1a447-382a-5a4f-14E4-1657103C169D","a6b1a447-382a-5a4f-14E4-1657103C3383","a6b1a447-382a-5a4f-14E4-1657103C22BE"],"TypeOfChange":"1","Version":"1.45.0","VibList":[{"Name":"CP072704","Version":"1.45.0.1-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for SUSE Linux Enterprise Server is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a","SWKey":"tg3-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom tg3 Ethernet Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec50241ee6","SWKey":"kmod-tg3","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"HPE Broadcom NX1 Online Firmware Upgrade Utility VMware for HPE ProLiant Gen10 server series Only.","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_07066da472194e46b01f51fd1f","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-1657103c22be"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWHPP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57485050","Version":"HPD9"},{"DeviceName":"EH000600JWHPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5748504e","Version":"HPD9"},{"DeviceName":"EH000300JWHPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA14SXn0HPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5748504c","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8d68452816_0HPD9-2.1_amd64.deb","SHA1Sum":"ea44c071dba54b2d41fff760442e074d45f5f7bb","SHA256Sum":"4286a3a9edcbd4ac21cde76759f2cf3b5384333576231b3ee369eb88b1f7ea89","SHA512Sum":"5fc306db57dcd2c5a1e3b9509a724efaaca1014dfd8dbb7fc223714c3b8381841b384ad63be6e1b3f9f90b2a360470e0f54a140a72696d21408bf2c6aa9c48b4"}],"ComponentSizeInKB":3462,"CompsigList":["firmware-hdd-8d68452816_0HPD9-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/CP071707.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/TA14SXn0HPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071707.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8d68452816-HPD9-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071707.scexe"],"Name":"firmware-hdd-8d68452816_0HPD9-2.1_amd64.deb","SHA1Sum":"ea44c071dba54b2d41fff760442e074d45f5f7bb","SHA256Sum":"4286a3a9edcbd4ac21cde76759f2cf3b5384333576231b3ee369eb88b1f7ea89","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57485050","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3330-304a5748504c"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000900JWHPP, EH000600JWHPN and EH000300JWHPL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWHPP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWHPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWHPL","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_29591197caa7452cb1780e6e1f","SupportedDevices":["452340a5-3048-3030-3330-304a5748504c","452340a5-3048-3030-3630-304a5748504e","452340a5-3048-3030-3930-304a57485050"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"tg3-kmp-default-3.140b_k6.12.0_160000.5-2.sles16sp0.x86_64.rpm","SHA1Sum":"45360ff8a6c4c00e5bf63068b64318600d54a291","SHA256Sum":"b00471dc6dc78d6761c172a2de9c148ecb1bb16be52cb42d82b1279bd11a1301","SHA512Sum":"9be6292ae36ca76aef0c136b5e8d40741fb35d17177096731beb36192a6057687b9ad38f0af12c166a3f659370bcc956817d81fa9ad867143d6a99e4b1e1d0a3"}],"ComponentSizeInKB":159,"CompsigList":["tg3-kmp-default-3.140b_k6.12.0_160000.5-2.sles16sp0.x86_64.compsig"],"FileList":["./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/tg3.ko","./usr/share/smartupdate/tg3-kmp-default/component.xml"],"Name":"tg3-kmp-default-3.140b_k6.12.0_160000.5-2.sles16sp0.x86_64.rpm","SHA1Sum":"45360ff8a6c4c00e5bf63068b64318600d54a291","SHA256Sum":"b00471dc6dc78d6761c172a2de9c148ecb1bb16be52cb42d82b1279bd11a1301","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec97b55b7a"],"TypeOfChange":"1","Version":"3.140b-2"}],"InstallationDependency":{},"Name":"HPE Broadcom tg3 Ethernet Drivers for SUSE Linux Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"tg3-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_93922329b20f4bc5879e77cd0e","SupportedDevices":["a6b1a447-382a-5a4f-14e4-165714e4159d","a6b1a447-382a-5a4f-14e4-165714e41591","a6b1a447-382a-5a4f-14e4-165714e41590","a6b1a447-382a-5a4f-14e4-1665103c22bd","a6b1a447-382a-5a4f-14e4-165f103c22e8","a6b1a447-382a-5a4f-14e4-165f103c1786","a6b1a447-382a-5a4f-14e4-1657103c169d","a6b1a447-382a-5a4f-14e4-1657103c22be","a6b1a447-382a-5a4f-14e4-1657103c3383","a6b1a447-382a-5a4f-14e4-165f14e4159c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U54","U54","U54","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U40","02020001","03020101","A42","U56","U61","U60","U58","U58","03030202","U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U39","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GYDKP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304759444b50","Version":"HPG3"},{"DeviceName":"MB012000GYCJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304759434a4c","Version":"HPG3"},{"DeviceName":"MB014000GYCJT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304759434a54","Version":"HPG3"},{"DeviceName":"MB016000GYDKQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304759444b51","Version":"HPG3"},{"DeviceName":"MB018000GYDKR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVSBPTG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759444b52","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068737.exe","SHA1Sum":"ff9b3c91bffeea49c49a11857818809d16c7fa82","SHA256Sum":"bbef212dd316bbbfbec78b4e3050578a11ed5c572df48e9b950684c040875edb","SHA512Sum":"3ae34bf70e7fc2c2b64fba58f53fcaab3c2987289c3db5a592b1f63d6e43251b8213792a97101cb91be83b21e0731b830c652bfd2642aa68225a397934bd0a30"}],"ComponentSizeInKB":3945,"CompsigList":["cp068737.compsig"],"FileList":["cp068737.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","SHPEEVSBPTG3.rel"],"Name":"cp068737.exe","SHA1Sum":"ff9b3c91bffeea49c49a11857818809d16c7fa82","SHA256Sum":"bbef212dd316bbbfbec78b4e3050578a11ed5c572df48e9b950684c040875edb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB010000GYDKP, MB012000GYCJL, MB014000GYCJT, MB016000GYDKQ and MB018000GYDKR Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GYDKP","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GYCJL","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GYCJT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GYDKQ","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYDKR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cd123e76da4e4e189a0aa46bfb","SupportedDevices":["4d2340a5-3042-3031-3030-304759444b50","4d2340a5-3042-3631-3030-304759444b51","4d2340a5-3042-3831-3030-304759444b52","4d2340a5-3042-3231-3030-304759434a4c","4d2340a5-3042-3431-3030-304759434a54"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a57435048","Version":"HPDD"},{"DeviceName":"EH000600JWCPF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTEDD.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a57435046","Version":"HPDD"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a05f29cef3_0HPDD-2.1_amd64.deb","SHA1Sum":"b6c73d0f1c0f1e3241d3895f69848e5cfbe6629d","SHA256Sum":"e0af644a9d0c578a365819ab7d0aea973c8be7e25f2e5a9d694afc393ceb215b","SHA512Sum":"7f40fd1f39d91a58a738b1fd7c813186c7d79d860cba629d93c59d755980edd82f0e1cc79c88c43c0b78c0f4eb7390e1721e4f0bff79e5ef4a63e193a3a117fa"}],"ComponentSizeInKB":4297,"CompsigList":["firmware-hdd-a05f29cef3_0HPDD-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/CP071705.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/SKESTEDD.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071705.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-a05f29cef3-HPDD-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071705.scexe"],"Name":"firmware-hdd-a05f29cef3_0HPDD-2.1_amd64.deb","SHA1Sum":"b6c73d0f1c0f1e3241d3895f69848e5cfbe6629d","SHA256Sum":"e0af644a9d0c578a365819ab7d0aea973c8be7e25f2e5a9d694afc393ceb215b","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a57435048","452340a5-3048-3030-3630-304a57435046"],"TypeOfChange":"1","Version":"HPDD"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000600JWCPF and EH000900JWCPH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPF","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e1fcb8ec58a141648617858208","SupportedDevices":["452340a5-3048-3030-3630-304a57435046","452340a5-3048-3030-3930-304a57435048"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-c993b31232_0HPG6-2.1_amd64.deb","SHA1Sum":"f954f0a9dd6bf8bd055954516616b5455e9c4120","SHA256Sum":"7398842598e348c654e3768fdba680eb1487926a6b6cbce5dabf5fbbe08a6549","SHA512Sum":"2fba5a8f65e783ac461e83acd8ede9374f12c5c44121ea1a730d2943bbc32221f16444bcf0b94bfd1707292ae17e2e9bb3af9531a8e81b56517495053d0de260"}],"ComponentSizeInKB":3546,"CompsigList":["firmware-hdd-c993b31232_0HPG6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/CP071716.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/TAMG06ACHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071716.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-c993b31232-HPG6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071716.scexe"],"Name":"firmware-hdd-c993b31232_0HPG6-2.1_amd64.deb","SHA1Sum":"f954f0a9dd6bf8bd055954516616b5455e9c4120","SHA256Sum":"7398842598e348c654e3768fdba680eb1487926a6b6cbce5dabf5fbbe08a6549","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000GWJRR and MB008000GWJRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_11baeec6941e42e1b4374b3c30","SupportedDevices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"CP070956.zip","SHA1Sum":"21c0afc183d123936ff5b2df66b692da2cb47361","SHA256Sum":"c15c52167860613925307bc387c4d81ac02a9ae187d58bfd0236da648fc2afbf","SHA512Sum":"faccbba8606b8a804e6aeb3e7dcd3c538113413f51d1a57bdae924464db657f0a1356d0b5afb09cf0bfb231144492dd2143a33037307a73b5baa5431880f429b"}],"ComponentSizeInKB":17704,"CompsigList":["CP070956.compsig"],"FileList":["/CP070956_BUILD_6.data","/CP070956.vmexe64","/CP070956.vmfile","/CP070956_VMw.zip","/CP070956.xml","/payload.json","/CP070956_VMw.zip/index.xml","/CP070956_VMw.zip/vendor-index.xml","/CP070956_VMw.zip/metadata.zip","/CP070956_VMw.zip/vib20/CP070956/HPE_bootbank_CP070956_HPD9.6-8.0.0.20613240.vib","/CP070956_VMw.zip/metadata.zip/vendor-index.xml","/CP070956_VMw.zip/metadata.zip/vmware.xml","/CP070956_VMw.zip/metadata.zip/vibs/CP070956-7036912924534481294.xml","/CP070956_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070956_HPD9.6-8.0.0.20613240.xml"],"Name":"CP070956.zip","SHA1Sum":"21c0afc183d123936ff5b2df66b692da2cb47361","SHA256Sum":"c15c52167860613925307bc387c4d81ac02a9ae187d58bfd0236da648fc2afbf","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9","VibList":[{"Name":"CP070956","Version":"HPD9.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000JWJRQ and MB006000JWJRP  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cb75fa0c275f484ab481512353","SupportedDevices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072314.zip","SHA1Sum":"c67347b8602aa76089dfe9afb32de5b4af62376e","SHA256Sum":"53f3378eec80ca2f3f6a0e6be86b65dd02df6a0944ce47e3c6612abf425e9fec","SHA512Sum":"896941bd5ec1eb53e6c810476340c1be8c240baaf259d244edef3cac0aceded6beb9276e43cde9eae25b412f518f700dcb9097804162962d7160be119e042bc7"}],"ComponentSizeInKB":260,"CompsigList":["cp072314.compsig"],"FileList":["/cp072314.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/index.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/vib20/i40en/INT_bootbank_i40en_2.12.1.0-1OEM.900.0.24755229.vib","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/i40en-6330660836031686988.xml","/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-i40en_2.12.1.0-1OEM.900.0.24755229.xml"],"Name":"cp072314.zip","SHA1Sum":"c67347b8602aa76089dfe9afb32de5b4af62376e","SHA256Sum":"53f3378eec80ca2f3f6a0e6be86b65dd02df6a0944ce47e3c6612abf425e9fec","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec09108524","20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"i40en","Version":"2.12.1.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Intel i40en Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-i40en:2.12.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"i40en:2.12.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a298daf2c00a4112b72e934e6f","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U36","U43","U41","U33","U44","A47","A48","U47","U37","A46","U47","U38","U38","U48","02020001","03020101","A42","U56","U61","U60","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM238.1.169.0_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41598","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM238.1.169.0_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41598","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM238.1.169.0_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41598","Version":"238.1.169.0"}]},"Files":[{"Checksum":[{"Filename":"BCM238.1.169.0_BCM957504-N425H.fwpkg","SHA1Sum":"812823f331ffe37017989cf730428c5f5a74b6ba","SHA256Sum":"aa903110cd00ade271367cd1e1b1e55d224f1394ee2a700e538f46c5fa23c698","SHA512Sum":"40d22847df3cd8da5b6efb6c68820310fe7865eddcab82e64ba20359ee096a128fef2e61c49e280656e15ce6d3e168cd50e1e4516a46b682c4a4bbcb979450c3"}],"ComponentSizeInKB":2921,"CompsigList":[],"FileList":["BCM238.1.169.0_BCM957504-N425H.HPb","BCM238.1.169.0_BCM957504-N425H.xml","payload.json"],"Name":"BCM238.1.169.0_BCM957504-N425H.fwpkg","SHA1Sum":"812823f331ffe37017989cf730428c5f5a74b6ba","SHA256Sum":"aa903110cd00ade271367cd1e1b1e55d224f1394ee2a700e538f46c5fa23c698","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41598"],"TypeOfChange":"1","Version":"238.1.169.0"}],"InstallationDependency":{},"MinimumActiveVersion":"235.1.220.0","Name":"Broadcom Firmware Package for BCM57504 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE_57504OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2170602668a2423aa4d1e97725","SupportedDevices":["a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41598"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","U43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","H10","H10","H10","U46"],"Type":"ComboFirmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000GWZGT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-3047575a4754","Version":"HPG1"},{"DeviceName":"MB012000GWZGU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-3047575a4755","Version":"HPG1"},{"DeviceName":"MB014000GWZGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-3047575a4756","Version":"HPG1"},{"DeviceName":"MB016000GWZHD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSTG1.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-3047575a4844","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-7a1edae8e7_0HPG1-2.1_amd64.deb","SHA1Sum":"590f18240e036bfb730ca957387e960f14155fb2","SHA256Sum":"c014de7ba2fa3ef975bd6d8ab530ecf1a78bb25235ce742f1bbb4d499a5e1c3e","SHA512Sum":"5ed5e17fe303415c3984c13052ad6c3402bb3be2a46c731613e552dcb00e5da59fd43881b9dd05fc8e4dce6f391002d1b67ee412760f939e971f0d2588d8d156"}],"ComponentSizeInKB":4331,"CompsigList":["firmware-hdd-7a1edae8e7_0HPG1-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/CP071734.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/SHPEEVANSTG1.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071734.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-7a1edae8e7-HPG1-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071734.scexe"],"Name":"firmware-hdd-7a1edae8e7_0HPG1-2.1_amd64.deb","SHA1Sum":"590f18240e036bfb730ca957387e960f14155fb2","SHA256Sum":"c014de7ba2fa3ef975bd6d8ab530ecf1a78bb25235ce742f1bbb4d499a5e1c3e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB010000GWZGT, MB012000GWZGU, MB014000GWZGV and MB016000GWZHD Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000GWZGT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB012000GWZGU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GWZGV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GWZHD","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_52bc509801ad42b3a223b55a57","SupportedDevices":["4d2340a5-3042-3031-3030-3047575a4754","4d2340a5-3042-3231-3030-3047575a4755","4d2340a5-3042-3431-3030-3047575a4756","4d2340a5-3042-3631-3030-3047575a4844"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWTBK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a5754424b","Version":"HPDB"},{"DeviceName":"VO001920JWTBL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a5754424c","Version":"HPDB"},{"DeviceName":"VO003840JWTBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a5754424e","Version":"HPDB"},{"DeviceName":"VO007680JWTBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a57544250","Version":"HPDB"},{"DeviceName":"MO000400JWTBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3430-304a57544251","Version":"HPDB"},{"DeviceName":"MO000800JWTBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-304a57544252","Version":"HPDB"},{"DeviceName":"MO001600JWTBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304a57544254","Version":"HPDB"},{"DeviceName":"MO003200JWTBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304a57544255","Version":"HPDB"},{"DeviceName":"MO006400JWTCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304a57544344","Version":"HPDB"},{"DeviceName":"EO000400JWTBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-304a57544256","Version":"HPDB"},{"DeviceName":"EO000800JWTCA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-304a57544341","Version":"HPDB"},{"DeviceName":"EO001600JWTCB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-304a57544342","Version":"HPDB"},{"DeviceName":"EO003200JWTCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3330-3230-304a57544343","Version":"HPDB"},{"DeviceName":"MO001920JWWWV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM5ALSHPDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-304a57575756","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-9ad359dac1_0HPDB-2.1_amd64.deb","SHA1Sum":"be965a5ed17185cd1a755053defaf8e883e87b34","SHA256Sum":"0f312c64f7787f8f9372066bd0e595b0ac9c294bf41e92f1e6044a64f743dd69","SHA512Sum":"0ca3da9bb857c8c6a7fd5ee8b51d895473fac252881da7353519436ca66e4e48c8960fa8acd10cfcc8de2d78361b040b324bbcb8b4a98a1f51aa9de08c797c04"}],"ComponentSizeInKB":3508,"CompsigList":["firmware-hdd-9ad359dac1_0HPDB-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/CP071751.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/KAPM5ALSHPDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071751.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-9ad359dac1-HPDB-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071751.scexe"],"Name":"firmware-hdd-9ad359dac1_0HPDB-2.1_amd64.deb","SHA1Sum":"be965a5ed17185cd1a755053defaf8e883e87b34","SHA256Sum":"0f312c64f7787f8f9372066bd0e595b0ac9c294bf41e92f1e6044a64f743dd69","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a5754424b","562340a5-304f-3130-3932-304a5754424c","562340a5-304f-3330-3834-304a5754424e","562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3030-3430-304a57544251","4d2340a5-304f-3030-3830-304a57544252","4d2340a5-304f-3130-3630-304a57544254","4d2340a5-304f-3330-3230-304a57544255","4d2340a5-304f-3630-3430-304a57544344","452340a5-304f-3030-3430-304a57544256","452340a5-304f-3030-3830-304a57544341","452340a5-304f-3130-3630-304a57544342","452340a5-304f-3330-3230-304a57544343","4d2340a5-304f-3130-3932-304a57575756"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64)  - VO000960JWTBK, VO001920JWTBL, VO003840JWTBN, VO007680JWTBP, MO000400JWTBQ, MO000800JWTBR, MO001600JWTBT, MO003200JWTBU, MO006400JWTCD, EO000400JWTBV, EO000800JWTCA and EO001600JWTCB Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWTBK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWTBL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWTBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWTBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000400JWTBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800JWTBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600JWTBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200JWTBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400JWTCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000400JWTBV","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800JWTCA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600JWTCB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO003200JWTCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001920JWWWV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_803b22d0f60d4e3c9d1127aab8","SupportedDevices":["562340a5-304f-3730-3638-304a57544250","4d2340a5-304f-3630-3430-304a57544344","562340a5-304f-3330-3834-304a5754424e","4d2340a5-304f-3330-3230-304a57544255","452340a5-304f-3330-3230-304a57544343","562340a5-304f-3130-3932-304a5754424c","4d2340a5-304f-3130-3630-304a57544254","452340a5-304f-3130-3630-304a57544342","562340a5-304f-3030-3936-304a5754424b","4d2340a5-304f-3030-3830-304a57544252","452340a5-304f-3030-3830-304a57544341","4d2340a5-304f-3030-3430-304a57544251","452340a5-304f-3030-3430-304a57544256","4d2340a5-304f-3130-3932-304a57575756"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_OCP_5p0_NCSIwPLDMoMCTP_80021BD3.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"5.00"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA2_SD_OCP_5p0_NCSIwPLDMoMCTP_80021BD3.fwpkg","SHA1Sum":"83f4f3371ee111777d402b41bd72cdb366f1823f","SHA256Sum":"61d593f7a0d7c813a78da3a598f85c109a0ae78f83d09f6507ffaf7b602e8f81","SHA512Sum":"6508e5a9ca07dfa88a57845c82a4c4718b4c670782c158908e26093c17d396720e166aff743df1611e396fb74baa8bb2551004b589ae35f0164b53328c437320"}],"ComponentSizeInKB":10280,"CompsigList":[],"FileList":["HPE_E810_XXVDA2_SD_OCP_5p0_NCSIwPLDMoMCTP_80021BD3.HPb","HPE_E810_XXVDA2_SD_OCP_5p0_NCSIwPLDMoMCTP_80021BD3.xml","payload.json"],"Name":"HPE_E810_XXVDA2_SD_OCP_5p0_NCSIwPLDMoMCTP_80021BD3.fwpkg","SHA1Sum":"83f4f3371ee111777d402b41bd72cdb366f1823f","SHA256Sum":"61d593f7a0d7c813a78da3a598f85c109a0ae78f83d09f6507ffaf7b602e8f81","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860005"],"TypeOfChange":"1","Version":"5.00"}],"InstallationDependency":{},"MinimumActiveVersion":"4.20","Name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cb6b294299aa42c7a41b4dbe1a","SupportedDevices":["a6b1a447-382a-5a4f-8086-159b80860005"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65","H11","A58","U66","U68","A59","A66","A66","U77"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-hp-i40e-2.30.18-1.rhel9u7.x86_64.rpm","SHA1Sum":"e60e9a8e75326e114cfd7c2df95785ca1fe3f439","SHA256Sum":"1c0e5944ae2719b1c2c5356ef931cabfb87c6395330549391eeaad102295f60b","SHA512Sum":"c9956ac181fa031f9201b67e601ca100bb00faee69cd75d7708a25cf73a91421b5bc15160134b9204563c86eb170f39f7b530f15e923055edaa8a4978f7854ef"}],"ComponentSizeInKB":461,"CompsigList":["kmod-hp-i40e-2.30.18-1.rhel9u7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.14.0-611.5.1.el9_7.x86_64","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-i40e","./lib/modules/5.14.0-611.5.1.el9_7.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/90","./usr/lib/.build-id/90/34b3cbea5c83b0a596a6cfda916462f325b718","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"Name":"kmod-hp-i40e-2.30.18-1.rhel9u7.x86_64.rpm","SHA1Sum":"e60e9a8e75326e114cfd7c2df95785ca1fe3f439","SHA256Sum":"1c0e5944ae2719b1c2c5356ef931cabfb87c6395330549391eeaad102295f60b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"TypeOfChange":"1","Version":"2.30.18-1"},{"Checksum":[{"Filename":"kmod-hp-i40e-2.30.18-1.rhel9u8.x86_64.rpm","SHA1Sum":"2d945ef72416b3d3253e55562ff0eaf42ace9606","SHA256Sum":"979707801c04b30627dbf2218a46e921d4f20cbc644118be71a28156b4d37c18","SHA512Sum":"9d77f599685535f252c087edc0648f3de3ed7d5c7c16dc02b5442673dfc751790a0880b010f6aa370e86a5a94f71c9af3f4df58648247adfd1006b0f79076f03"}],"ComponentSizeInKB":446,"CompsigList":["kmod-hp-i40e-2.30.18-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-i40e","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/hp-i40e/i40e.ko","./usr/lib/.build-id","./usr/lib/.build-id/b6","./usr/lib/.build-id/b6/374d611b40b4132ecb46977cbc6085af6d270d","./usr/share/smartupdate/kmod-hp-i40e/component.xml"],"Name":"kmod-hp-i40e-2.30.18-1.rhel9u8.x86_64.rpm","SHA1Sum":"2d945ef72416b3d3253e55562ff0eaf42ace9606","SHA256Sum":"979707801c04b30627dbf2218a46e921d4f20cbc644118be71a28156b4d37c18","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec243e7654"],"TypeOfChange":"1","Version":"2.30.18-1"}],"InstallationDependency":{},"Name":"HPE Intel i40e Drivers for Red Hat Enterprise Linux 9","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-hp-i40e","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e4592e282a694d268e8a361696","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U37","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U37_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020e","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U37_3.70_08_19_2026.fwpkg","SHA1Sum":"ffbe27f0e36d774f02110fca12cf51afbe0c48cd","SHA256Sum":"27fbb932297f1aab5da7c7592d74eea33870a06498d5619f191b66a0a55214a9","SHA512Sum":"e6c02707fdcac9371f46a0e77e54d396c6bdf9e01db62958ef5757af1dc25d1de6ff1d1a3c742f5632d5d30a81b1a8ef1552857c369e166db27ebaa2f16f4b08"}],"ComponentSizeInKB":32822,"CompsigList":[],"FileList":["payload.json","U37_3.70_08_19_2026.signed.flash","U37_3.70_08_19_2026.xml"],"Name":"U37_3.70_08_19_2026.fwpkg","SHA1Sum":"ffbe27f0e36d774f02110fca12cf51afbe0c48cd","SHA256Sum":"27fbb932297f1aab5da7c7592d74eea33870a06498d5619f191b66a0a55214a9","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020e"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant XL230k Gen10 (U37) Server","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U37","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f855e8a94c7340d8913844e773","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.0","6.5","6.7","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U37"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"907BF452-0F78-4311-AB8A-4FC6F1C1688E","Devices":{"Device":[{"DeviceName":"HPE Apollo 2000 Gen10Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd1838329e6c","Version":"1.27"},{"DeviceName":"HPE Apollo 2000 Gen10 Plus Backplane Expander","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"Capitola-Release-1.27.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"b99dfb74-f0bc-464f-b418-cd18275727b1","Version":"1.27"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-7b5e8400dd-1.27-6.1.x86_64.rpm","SHA1Sum":"131505ac84428aeb7be6742d622f1c3db69a4718","SHA256Sum":"511f2f81e35f78454da2a2142e130ea88428529872786bb6dac59bfcf415e2ec","SHA512Sum":"5e94bbb1d22235e9244e19b6dd1d71531a641628537ac896cb10fdc903d1778a3625435490ebca0d9265d35959244bdec394567d582370c072849738e10ba131"}],"ComponentSizeInKB":4951,"CompsigList":["firmware-smartarray-7b5e8400dd-1.27-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/CP068824.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/Capitola-Release-1.27.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-7b5e8400dd-1.27-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068824.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068824.scexe"],"Name":"firmware-smartarray-7b5e8400dd-1.27-6.1.x86_64.rpm","SHA1Sum":"131505ac84428aeb7be6742d622f1c3db69a4718","SHA256Sum":"511f2f81e35f78454da2a2142e130ea88428529872786bb6dac59bfcf415e2ec","SoftwarePlatforms":[],"TargetGUIDs":["b99dfb74-f0bc-464f-b418-cd1838329e6c","b99dfb74-f0bc-464f-b418-cd18275727b1"],"TypeOfChange":"1","Version":"1.27"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.50 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.50 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 2.95 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 2.95 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.95"}]},{"ListConditional":"AND","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"},{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]}]}]},"Name":"Online ROM Flash Component for Linux (x64) – HPE Apollo 2000 Gen10 Plus Backplane Expander FW","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"no","SWKeys":[{"Name":"Apollo 2000 G10P","SWKeyExpectedPath":"firmware:sd:sasexpander"},{"Name":"Capitola","SWKeyExpectedPath":"firmware:sd:sasexpander"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_81f6023a6657428ba79e3359d8","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U47","U47","A46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JYDNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a59444e46","Version":"HPD5"},{"DeviceName":"MB008000JYDPC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a59445043","Version":"HPD5"},{"DeviceName":"MB010000JYDNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARBPESD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a59444e48","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"cp068735.exe","SHA1Sum":"4e72ebdee545c54609248f4195c30bc5cc93ef1d","SHA256Sum":"6e05dbc080161ac07ca9ab5d5346f520be2bde3a47b8da9a2a9bbd516c93f92a","SHA512Sum":"0228ca1fbf3fc1dc1b877e3ddbef1d95044b6e458559ccf8257eb410e307bf680f8e955f3af8e81270d9be67412053b2badfa7a9fd4b6a8c86261a625e1c8e4f"}],"ComponentSizeInKB":4547,"CompsigList":["cp068735.compsig"],"FileList":["cp068735.xml","cpqsetup.exe","mnv_cli.exe","payload.json","SCIMARBPESD5.rel","setup.dll"],"Name":"cp068735.exe","SHA1Sum":"4e72ebdee545c54609248f4195c30bc5cc93ef1d","SHA256Sum":"6e05dbc080161ac07ca9ab5d5346f520be2bde3a47b8da9a2a9bbd516c93f92a","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000JYDNF, MB008000JYDPC and MB010000JYDNH Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JYDNF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB008000JYDPC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB010000JYDNH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3fd1113df84b4bf58e44e3280c","SupportedDevices":["4d2340a5-3042-3630-3030-304a59444e46","4d2340a5-3042-3830-3030-304a59445043","4d2340a5-3042-3031-3030-304a59444e48"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000480GZCNE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a434e45","Version":"HPG3"},{"DeviceName":"VK000960GZCNF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a434e46","Version":"HPG3"},{"DeviceName":"VK001920GZCNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a434e48","Version":"HPG3"},{"DeviceName":"VK003840GZCNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"K511HPG3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a434e4b","Version":"HPG3"}]},"Files":[{"Checksum":[{"Filename":"cp068634.exe","SHA1Sum":"9518cba68a31f21b2a866d9f26f50625e4f992ad","SHA256Sum":"185b50ee0d312409eeca9994b2412f5f669f7bed8032ecc2a937d9b54c60b51a","SHA512Sum":"680b67937db3b315881426697c4eb4ff8b5f78486d011afb07e9b18622dc17dd0dcfa456defe68a14c8a2b09b93e706df832d2ceead839b0bd03a8e7525dbd18"}],"ComponentSizeInKB":8000,"CompsigList":["cp068634.compsig"],"FileList":["cp068634.xml","cpqsetup.exe","K511HPG3.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068634.exe","SHA1Sum":"9518cba68a31f21b2a866d9f26f50625e4f992ad","SHA256Sum":"185b50ee0d312409eeca9994b2412f5f669f7bed8032ecc2a937d9b54c60b51a","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"TypeOfChange":"1","Version":"HPG3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VK000480GZCNE, VK000960GZCNF, VK001920GZCNH and VK003840GZCNK  Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000480GZCNE","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZCNF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZCNH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZCNK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3695033488784f1a95f15765ce","SupportedDevices":["562340a5-304b-3030-3438-30475a434e45","562340a5-304b-3030-3936-30475a434e46","562340a5-304b-3130-3932-30475a434e48","562340a5-304b-3330-3834-30475a434e4b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072320.zip","SHA1Sum":"26f4489ae0534a15ece24b1ca04d405256c7b6c3","SHA256Sum":"0801e02147b8be1a0f85a759d19c9aabf8d6b85a8b3aeb1c1fb953c47c844fb4","SHA512Sum":"2139f672ab69fd0c16da471edbeedc1d87b78e4d07b1952bcc3339825a996e959cb2593cf913519f4b982076ccdce1efe7e71da7ab3ab755891dc4d7c76958e0"}],"ComponentSizeInKB":211,"CompsigList":["cp072320.compsig"],"FileList":["/cp072320.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/index.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/vendor-index.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/vib20/ixgben/INT_bootbank_ixgben_1.24.1.0-1OEM.900.0.24755229.vib","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip/vendor-index.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip/vmware.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip/vibs/ixgben--6710869395507768838.xml","/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.zip/metadata.zip/bulletins/Intel-ixgben_1.24.1.0-1OEM.900.0.24755229.xml"],"Name":"cp072320.zip","SHA1Sum":"26f4489ae0534a15ece24b1ca04d405256c7b6c3","SHA256Sum":"0801e02147b8be1a0f85a759d19c9aabf8d6b85a8b3aeb1c1fb953c47c844fb4","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6164afab","20a6e8e4-bf33-4c71-a6bf-d9ec4a9c3d5c"],"TypeOfChange":"1","Version":"2026.09.00","VibList":[{"Name":"ixgben","Version":"1.24.1.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"HPE Intel ixgben Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Intel-ixgben:1.24.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"ixgben:1.24.1.0-1OEM.900.0.24755229","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4923144a117d4af398b478e169","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U68","U68","U68","U71","U69","U69","U71","U72","U72","U70","U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U39","U45","U37","U38","U38","02020001","03020101","A59","U77","A66","A66","03020102","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"}]},"Files":[{"Checksum":[{"Filename":"CP070911.zip","SHA1Sum":"295a9eec732210809dcb6eb52ff5cb67ac508234","SHA256Sum":"513c54f89796fc25c597cceb8e36af79e7edeacd36c3175a01313fd314f4b5d9","SHA512Sum":"afbd229641061f9bdb9f2c49f3dfe95864a728d9799724dbc8a9b4386acacf7a290ea1e636a9d6f659d0412a8d19fec24fe7207f2d20fc00675be18f96c0dcb4"}],"ComponentSizeInKB":26910,"CompsigList":["CP070911.compsig"],"FileList":["/CP070911_BUILD_4.data","/CP070911.vmexe64","/CP070911.vmfile","/CP070911_VMw.zip","/CP070911.xml","/payload.json","/CP070911_VMw.zip/index.xml","/CP070911_VMw.zip/vendor-index.xml","/CP070911_VMw.zip/metadata.zip","/CP070911_VMw.zip/vib20/CP070911/HPE_bootbank_CP070911_MPK78H5Q.4-8.0.0.20613240.vib","/CP070911_VMw.zip/metadata.zip/vendor-index.xml","/CP070911_VMw.zip/metadata.zip/vmware.xml","/CP070911_VMw.zip/metadata.zip/vibs/CP070911--141142834386941589.xml","/CP070911_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070911_MPK78H5Q.4-8.0.0.20613240.xml"],"Name":"CP070911.zip","SHA1Sum":"295a9eec732210809dcb6eb52ff5cb67ac508234","SHA256Sum":"513c54f89796fc25c597cceb8e36af79e7edeacd36c3175a01313fd314f4b5d9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17"],"TypeOfChange":"1","Version":"MPK78H5Q","VibList":[{"Name":"CP070911","Version":"MPK78H5Q.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for VMware ESXi - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-00H3 Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_99e61b9a2e584586a3104d791d","SupportedDevices":["4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3936-304894dc03d2"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u8.x86_64.rpm","SHA1Sum":"62464cd2f6c755cde05eb6374f3a0cbc70307974","SHA256Sum":"700b6a45deb3f05b431a2ee4f30bc6cb3be4908ef2f43f09e912aaad5263f83a","SHA512Sum":"e2562eb02ed7a98e46928fc664ee69f7ea64f43e174836d121589396d3d0a0a8a0aa89ad084f4bfc3349e77fbf2a50ee45866ff7eca13f5393751c32e16d2f44"}],"ComponentSizeInKB":5320,"CompsigList":["kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u8.x86_64.compsig"],"FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/5.14.0-687.5.3.el9_8.x86_64","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-qla2xxx","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/modules/5.14.0-687.5.3.el9_8.x86_64/extra/qlgc-qla2xxx/tcm_qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"Name":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel9u8.x86_64.rpm","SHA1Sum":"62464cd2f6c755cde05eb6374f3a0cbc70307974","SHA256Sum":"700b6a45deb3f05b431a2ee4f30bc6cb3be4908ef2f43f09e912aaad5263f83a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 9 Update 8 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_20f29c5efa6444618ec3b6a83c","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-238.1.165.0-sles15sp7.x86_64.rpm","SHA1Sum":"2c07b96b9da226ffb75206440e18c89d189e3442","SHA256Sum":"09731d08c859095aa28412a50dd8ed2671f8d3032f8c9f83b07b1441c9522e0a","SHA512Sum":"11b194cf6e93ebad687748f345cda7b90c366e53f0eebd5eef3a982fe6e0721f629f3d3f4cfb7dc044df1d6480d2546c7fcc4caa9d4d8666e303666ca4886b5b"}],"ComponentSizeInKB":61,"CompsigList":["libbnxt_re-238.1.165.0-sles15sp7.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-238.1.165.0.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/lib64/pkgconfig/libbnxt_re.pc","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-238.1.165.0-sles15sp7.x86_64.rpm","SHA1Sum":"2c07b96b9da226ffb75206440e18c89d189e3442","SHA256Sum":"09731d08c859095aa28412a50dd8ed2671f8d3032f8c9f83b07b1441c9522e0a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 15 SP7","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_37174802f3a942d08fd3871e3c","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JWXKH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08scHPDC.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a57584b48","Version":"HPDC"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8a0371a425_0HPDC-2.1_amd64.deb","SHA1Sum":"06a5325f50491fa51b3a58c10b60c3ab78b4f3ed","SHA256Sum":"6062ebb198c31d868b5a8f66cfbc9d8a7b3669c3d57cb91836bf7db3c204b94c","SHA512Sum":"375d445e6cd6e95198950abbb45c7ba6adac4d010864fe91975b060225bb7872183d946fede8d8b57b96ebd406821d81b83a34fd73ed091c9f3d41986efcf081"}],"ComponentSizeInKB":4359,"CompsigList":["firmware-hdd-8a0371a425_0HPDC-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/CP071792.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/TAMG08scHPDC.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071792.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-8a0371a425-HPDC-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071792.scexe"],"Name":"firmware-hdd-8a0371a425_0HPDC-2.1_amd64.deb","SHA1Sum":"06a5325f50491fa51b3a58c10b60c3ab78b4f3ed","SHA256Sum":"6062ebb198c31d868b5a8f66cfbc9d8a7b3669c3d57cb91836bf7db3c204b94c","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a57584b48"],"TypeOfChange":"1","Version":"HPDC"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000JWXKH Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JWXKH","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2af1f4d7bca945e2b8044c7a3e","SupportedDevices":["4d2340a5-3042-3631-3030-304a57584b48"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-8f501d6cf1-HPD4-2.1.x86_64.rpm","SHA1Sum":"640c0e7e027bdc1c0daf4e7ecc77e1c4d443e386","SHA256Sum":"8ef4645dd66200255d41b97ab89a0b3d6e9cd02a618ba7134dafc9cb85237d05","SHA512Sum":"2b05ed68566ab8ac388d7655e218e9fec4fc95f51b325cc5ddb80be75890d1b003da0d24a08a86eaca5ca5a995961b4de99774418bdabb42a4ee4afc02a26bc5"}],"ComponentSizeInKB":5820,"CompsigList":["firmware-hdd-8f501d6cf1-HPD4-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/CP068924.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/KAPM6ALFHPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-8f501d6cf1-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068924.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068924.scexe"],"Name":"firmware-hdd-8f501d6cf1-HPD4-2.1.x86_64.rpm","SHA1Sum":"640c0e7e027bdc1c0daf4e7ecc77e1c4d443e386","SHA256Sum":"8ef4645dd66200255d41b97ab89a0b3d6e9cd02a618ba7134dafc9cb85237d05","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a01b30d9ab32481babdfa599e5","SupportedDevices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U60","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U60_2.70_08_20_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023e","Version":"v2.70 (08/20/2026)"}]},"Files":[{"Checksum":[{"Filename":"U60_2.70_08_20_2026.fwpkg","SHA1Sum":"1d59e9c6e080e71ac7132470e1bfbefc40ee6fda","SHA256Sum":"47744ec64004942f2776ffd1be17f5a0e38d25a8217b9263151ad537cbc30efa","SHA512Sum":"f1c2ab5055934c82df2d4b53649e1bc90ab1adba5b2bd976c8ca94be7719bf30698ad0779b5fa2e939870c41e3206f532f0a8cc513785bbc9acd9108cde10412"}],"ComponentSizeInKB":16423,"CompsigList":[],"FileList":["payload.json","U60_2.70_08_20_2026.signed.flash","U60_2.70_08_20_2026.xml"],"Name":"U60_2.70_08_20_2026.fwpkg","SHA1Sum":"1d59e9c6e080e71ac7132470e1bfbefc40ee6fda","SHA256Sum":"47744ec64004942f2776ffd1be17f5a0e38d25a8217b9263151ad537cbc30efa","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023e"],"TypeOfChange":"1","Version":"2.70_08-20-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Proliant DL20 Gen10 Plus Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U60","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_00c709c0f359490a8157934d80","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp062283.exe","SHA1Sum":"03cb53f778f555f25c0e1ff6e170779708406c66","SHA256Sum":"ba00e35789e7eb8272ff04131763e9c8b7f798aa3c322ba9a2ea09a9c74c6a3a","SHA512Sum":"456a0b4372d480e533f16c84e0cd9ab7e47d50b254242ba7fd042fd33bf4556d61ec5cc2f477a12b55249008fc5bab90a11fd8d9e6af8ef40c5435c3ad767870"}],"ComponentSizeInKB":562,"CompsigList":["cp062283.compsig"],"FileList":["cp062283.xml","cpqsetup.exe","generic.dll","install.xml","switchtec.cat","Switchtec.inf","Switchtec.sys"],"Name":"cp062283.exe","SHA1Sum":"03cb53f778f555f25c0e1ff6e170779708406c66","SHA256Sum":"ba00e35789e7eb8272ff04131763e9c8b7f798aa3c322ba9a2ea09a9c74c6a3a","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec00942bcf"],"TypeOfChange":"0","Version":"1.0.0.0"}],"InstallationDependency":{},"Name":"Switchtec PCIe Switch Management Driver for Microsoft Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"Switchtec.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_07a6f72217b54f3fa879777aa7","SupportedDevices":["a6b1a447-382a-5a4f-11f8-400011f84000","a6b1a447-382a-5a4f-11f8-405211f84052"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["I44","A47","A48","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-238.1.165.0-sles16sp0.x86_64.rpm","SHA1Sum":"65aa077e1a931304239743bc50e98ba8c58dcbd7","SHA256Sum":"276b18128b37589744ba67a5c1efbc69c6d48e633f411eba99af1a2e30a66901","SHA512Sum":"a0868df1c2e2e06af74a93a6d5676023a70b4382d5a886e16fe026ca75af9ca56b67b0fdb9fd7c560a810cfc5af007f0b5dbd1bd94ae8de3e2e865781d4caadf"}],"ComponentSizeInKB":282,"CompsigList":["libbnxt_re-238.1.165.0-sles16sp0.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib64/libbnxt_re-238.1.165.0.so","./usr/lib64/libbnxt_re-rdmav34.so","./usr/lib64/libbnxt_re.so","./usr/lib64/pkgconfig/libbnxt_re.pc","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-238.1.165.0-sles16sp0.x86_64.rpm","SHA1Sum":"65aa077e1a931304239743bc50e98ba8c58dcbd7","SHA256Sum":"276b18128b37589744ba67a5c1efbc69c6d48e633f411eba99af1a2e30a66901","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for SUSE Linux Enterprise Server 16 SP0","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_13b806cff46044c496bcc32ddd","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG6"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG6"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG6"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"CP070093.zip","SHA1Sum":"cfb6660b9f02412edab0bec8e72292839f11f8a1","SHA256Sum":"08078a87c65856307062d444c560312663dbbbdfb7c8ee3c94f1ca0a726a8009","SHA512Sum":"8fa36e96b0c032d1be04c15e16bdc98a55cdf20e9e62e72254297baaf0bda8a565ef1145b78bab11d42fd63a680b01514eb90f82b023c2051852b1547dcb0d66"}],"ComponentSizeInKB":19390,"CompsigList":["CP070093.compsig"],"FileList":["/CP070093_BUILD_6.data","/CP070093.vmexe64","/CP070093.vmfile","/CP070093_VMw.zip","/CP070093.xml","/payload.json","/CP070093_VMw.zip/index.xml","/CP070093_VMw.zip/vendor-index.xml","/CP070093_VMw.zip/metadata.zip","/CP070093_VMw.zip/vib20/CP070093/HPE_bootbank_CP070093_HPG6.6-8.0.0.20613240.vib","/CP070093_VMw.zip/metadata.zip/vendor-index.xml","/CP070093_VMw.zip/metadata.zip/vmware.xml","/CP070093_VMw.zip/metadata.zip/vibs/CP070093--8340103372554506873.xml","/CP070093_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070093_HPG6.6-8.0.0.20613240.xml"],"Name":"CP070093.zip","SHA1Sum":"cfb6660b9f02412edab0bec8e72292839f11f8a1","SHA256Sum":"08078a87c65856307062d444c560312663dbbbdfb7c8ee3c94f1ca0a726a8009","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG6","VibList":[{"Name":"CP070093","Version":"HPG6.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_56ae8d8bef5349878a95da4b3a","SupportedDevices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp6-1.x86_64.rpm","SHA1Sum":"4697c2cb6e57b5db24e3088295f9f59649234bed","SHA256Sum":"611d8e28b4ec21abc2d20aec6b4733be0cffb01a2b42ff9cf05f3bd07b238dfe","SHA512Sum":"304977a153fd1f681a6c30b13d5dad3698e6d66d6e527168a12ce482e5d249d11b980e5f9e878873ba35b84d0a043c2477aba203fc543cea9474badb1cbd6211"}],"ComponentSizeInKB":944,"CompsigList":["lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp6-1.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/megaraid_sas.ko","./usr/lib/.build-id","./usr/lib/.build-id/52","./usr/lib/.build-id/52/2274da4e9d116021bf84327f8d1d51bcbb704d","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"Name":"lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp6-1.x86_64.rpm","SHA1Sum":"4697c2cb6e57b5db24e3088295f9f59649234bed","SHA256Sum":"611d8e28b4ec21abc2d20aec6b4733be0cffb01a2b42ff9cf05f3bd07b238dfe","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.738.06.0"},{"Checksum":[{"Filename":"lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp7-1.x86_64.rpm","SHA1Sum":"fe33f9464db9934366a35d6f7e4527475fdde05b","SHA256Sum":"dd011621520abfa49642c3d821c5d2d07b00b88b8762d1e08c77a1d46c045326","SHA512Sum":"3d186caaaa31d3efdad3fdfe3c0448af2079ca186c4a470c55babca4c080df4d149b2495e6259d8a28abc4b96f1a0c60a1603ec7fec09dde90abda0934207ecd"}],"ComponentSizeInKB":927,"CompsigList":["lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp7-1.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/megaraid_sas.ko","./usr/lib/.build-id","./usr/lib/.build-id/fa","./usr/lib/.build-id/fa/a040e783710215b1d02ee9eb1fcffd2a529b9a","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"Name":"lsi-megaraid_sas-kmp-default-07.738.06.0_sles15sp7-1.x86_64.rpm","SHA1Sum":"fe33f9464db9934366a35d6f7e4527475fdde05b","SHA256Sum":"dd011621520abfa49642c3d821c5d2d07b00b88b8762d1e08c77a1d46c045326","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.738.06.0"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_55d4008462cd4be5bc02f61173","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U58","U54","U58","U63","U54","U54","U61","U60","U46","U30","U32","A42","A43","A43","A42","U59","U63","U46","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A59","A66","U71","A72","A66","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD6"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD6"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD6"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-87b796d9ae-HPD6-1.1.x86_64.rpm","SHA1Sum":"ee4c1c443e8f774233dfb3869921ad283096fac2","SHA256Sum":"2b4743100ebde6ee7f96ae2b8af842b6619f31ceb8be8994d998bf3a0bff2549","SHA512Sum":"034e2cc7656f2429680b45b8f69356053ee5ea20f1034bf66578c5b95137b7270687d875f12ce826e7bdb164e5345de19fad4f8870da4a05cb186d8303350915"}],"ComponentSizeInKB":5883,"CompsigList":["firmware-hdd-87b796d9ae-HPD6-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/CP070062.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/TAMG09scHPD6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070062.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070062.scexe"],"Name":"firmware-hdd-87b796d9ae-HPD6-1.1.x86_64.rpm","SHA1Sum":"ee4c1c443e8f774233dfb3869921ad283096fac2","SHA256Sum":"2b4743100ebde6ee7f96ae2b8af842b6619f31ceb8be8994d998bf3a0bff2549","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_90b9b789ed55414da53a2984ba","SupportedDevices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000021c","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000231","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A43","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A43_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000232","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-a43-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"234e908dbbf53bca8f703d0a7a5ed4bd2f16343d","SHA256Sum":"3c9c03dcad329c56c9112c73531f49362bc21ab992c0869e83625e5d45768043","SHA512Sum":"17b2f29181b673924412fadf2ba8a52025f23257ae3d01399bda949196e9ee36d981bd3de7887cf86fa8e4cafd34595db770970412777166b15882b2f80c0d62"}],"ComponentSizeInKB":33312,"CompsigList":["firmware-system-a43-4.04_2026_04_02-1.1.x86_64_part2.compsig","firmware-system-a43-4.04_2026_04_02-1.1.x86_64_part1.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/A43_4.04_04_02_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/CP071519.xml","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-a43-4.04_2026_04_02-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071519.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071519.scexe"],"Name":"firmware-system-a43-4.04_2026_04_02-1.1.x86_64.rpm","SHA1Sum":"234e908dbbf53bca8f703d0a7a5ed4bd2f16343d","SHA256Sum":"3c9c03dcad329c56c9112c73531f49362bc21ab992c0869e83625e5d45768043","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000021c","00000000-0000-0000-0000-000000000231","00000000-0000-0000-0000-000000000232"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL325/DL325 v2/DL345 Gen10 Plus (A43) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A43","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a21add1c10a04672be3c7db1b1","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A43","A43","A43"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-ixgbe-kmp-default-6.4.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"b746cb12108e5be06fe4a8ee7c4bfa573654a2e7","SHA256Sum":"29853d39abe8e9969286d35062f309387c81a153b195015b52679b3e880e6c78","SHA512Sum":"c821b81be65406badcd9356c4a8c2a0bce0d3405f26611117d1aa5e85338f4890a164a7061d92e9fa88dee9ba0cac430584f7765fd9afbc41013f25b288acdee"}],"ComponentSizeInKB":7142,"CompsigList":["hp-ixgbe-kmp-default-6.4.4_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe","./lib/modules/6.4.0-150600.21-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"Name":"hp-ixgbe-kmp-default-6.4.4_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"b746cb12108e5be06fe4a8ee7c4bfa573654a2e7","SHA256Sum":"29853d39abe8e9969286d35062f309387c81a153b195015b52679b3e880e6c78","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"TypeOfChange":"1","Version":"6.4.4-1"},{"Checksum":[{"Filename":"hp-ixgbe-kmp-default-6.4.4_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"709c3dfa4b54bde5a7943dd03d898cd40bd7e7ef","SHA256Sum":"df9c390502b2727d9d436ca4a5ce351362ef0a3e5dd31675c07911c1497f7b57","SHA512Sum":"2a8689c40573ed86b4e727ca8a77205e6982f813ec00f5bfcdc5fb26d8c9235abce31fd73cfbd13a840a14c6a557278dd05d840b33ecf3a2713490c0e85056bf"}],"ComponentSizeInKB":383,"CompsigList":["hp-ixgbe-kmp-default-6.4.4_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-ixgbe.conf","./etc/dracut.conf.d/hp-ixgbe-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbe","./lib/modules/6.4.0-150700.51-default/updates/hp-ixgbe/ixgbe.ko","./usr/share/smartupdate/hp-ixgbe-kmp-default/component.xml"],"Name":"hp-ixgbe-kmp-default-6.4.4_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"709c3dfa4b54bde5a7943dd03d898cd40bd7e7ef","SHA256Sum":"df9c390502b2727d9d436ca4a5ce351362ef0a3e5dd31675c07911c1497f7b57","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec22d08a36"],"TypeOfChange":"1","Version":"6.4.4-1"}],"InstallationDependency":{},"Name":"HPE Intel ixgbe Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-ixgbe-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d004682c90d34e4dbdb3d3289a","SupportedDevices":["a6b1a447-382a-5a4f-8086-57ad808600ff","a6b1a447-382a-5a4f-8086-57b180860003","a6b1a447-382a-5a4f-8086-57ad80860003","a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3","a6b1a447-382a-5a4f-8086-1528103c192d","a6b1a447-382a-5a4f-8086-1528103c211a","a6b1a447-382a-5a4f-8086-1563159000d2","a6b1a447-382a-5a4f-8086-1563159000d1","a6b1a447-382a-5a4f-8086-152E00000000","a6b1a447-382a-5a4f-8086-10ed103c17d0","a6b1a447-382a-5a4f-8086-10ed103c17d3","a6b1a447-382a-5a4f-8086-153000000000","a6b1a447-382a-5a4f-8086-1515103c192d","a6b1a447-382a-5a4f-8086-1515103c211a"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","J10","U40","U39","U45","U37","U38","U38","O43","U26","02020001","03020101","A59","U68","U68","U68","U71","U69","U69","U71","U72","U68","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK000240GZXRU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3234-30475a585255","Version":"HPG1"},{"DeviceName":"VK000480GZXRF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3438-30475a585246","Version":"HPG1"},{"DeviceName":"VK000960GZXQU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3030-3936-30475a585155","Version":"HPG1"},{"DeviceName":"VK001920GZXQV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3130-3932-30475a585156","Version":"HPG1"},{"DeviceName":"VK003840GZXRH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475a585248","Version":"HPG1"},{"DeviceName":"VK007680GZXRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPG1_PM893.bin","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3730-3638-30475a585254","Version":"HPG1"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-abd133f0de-HPG1-6.1.x86_64.rpm","SHA1Sum":"0780dd7bd4216ae12774d98d540f9e63e2c868d2","SHA256Sum":"5e601cfa863906f9685ef674999da38fda075053284c6743534631d9efb7af4d","SHA512Sum":"be0475987d7a38f6ab4abb732217f8ca04307d3f20ef252ae86898a12012363bc44711c30e13b7e9e77498f5ef37a858c5574696cb25e299195bf97db3ddfc5d"}],"ComponentSizeInKB":6634,"CompsigList":["firmware-hdd-abd133f0de-HPG1-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/CP068918.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/HPG1_PM893.bin","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-abd133f0de-HPG1-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068918.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068918.scexe"],"Name":"firmware-hdd-abd133f0de-HPG1-6.1.x86_64.rpm","SHA1Sum":"0780dd7bd4216ae12774d98d540f9e63e2c868d2","SHA256Sum":"5e601cfa863906f9685ef674999da38fda075053284c6743534631d9efb7af4d","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3030-3234-30475a585255","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254"],"TypeOfChange":"1","Version":"HPG1"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK000240GZXRU, VK000480GZXRF, VK000960GZXQU, VK001920GZXQV, VK003840GZXRH and VK007680GZXRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK000240GZXRU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000480GZXRF","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK000960GZXQU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK001920GZXQV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK003840GZXRH","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"VK007680GZXRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bdb052e5bc314474ac40768eeb","SupportedDevices":["562340a5-304b-3130-3932-30475a585156","562340a5-304b-3330-3834-30475a585248","562340a5-304b-3730-3638-30475a585254","562340a5-304b-3030-3936-30475a585155","562340a5-304b-3030-3438-30475a585246","562340a5-304b-3030-3234-30475a585255"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GZYVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-30475a595654","Version":"HPG6"},{"DeviceName":"MB014000GZYVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-30475a595655","Version":"HPG6"},{"DeviceName":"MB016000GZYVV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-30475a595656","Version":"HPG6"},{"DeviceName":"MB018000GYCLL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09acHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304759434c4c","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e0171a2936-HPG6-1.1.x86_64.rpm","SHA1Sum":"b925437ae57b1bc57647d3c8e16f306fe2dde516","SHA256Sum":"b1fe34857f491dbd3daca844ac3cc8d09838b0fafe6250e7fc9e6f248b63fa71","SHA512Sum":"329585d30bd8535bcba133b6dba6695287af83896ab46b16c2b58660b801429dec98cdaf7621f01ed4521948b9bea5bd2bdf9e17de201f6563456bbed864ed5d"}],"ComponentSizeInKB":5862,"CompsigList":["firmware-hdd-e0171a2936-HPG6-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/CP070087.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/TAMG09acHPG6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e0171a2936-HPG6-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070087.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070087.scexe"],"Name":"firmware-hdd-e0171a2936-HPG6-1.1.x86_64.rpm","SHA1Sum":"b925437ae57b1bc57647d3c8e16f306fe2dde516","SHA256Sum":"b1fe34857f491dbd3daca844ac3cc8d09838b0fafe6250e7fc9e6f248b63fa71","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GZYVT, MB014000GZYVU, MB016000GZYVV and MB018000GYCLL Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GZYVT","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB014000GZYVU","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB016000GZYVV","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB018000GYCLL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ed6630baf8aa499f80b331e47d","SupportedDevices":["4d2340a5-3042-3231-3030-30475a595654","4d2340a5-3042-3431-3030-30475a595655","4d2340a5-3042-3631-3030-30475a595656","4d2340a5-3042-3831-3030-304759434c4c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000GWRTC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL8WBA0HPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304757525443","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"CP073301.zip","SHA1Sum":"b865d934fba02a869c16fdb442c381056e3c25c3","SHA256Sum":"373445fba63fd7ca7171f3d225aa83c395eb7d4089c825fb6cb0b227b67151f9","SHA512Sum":"82811ff015b646a45a497fd06c8c03cc3c80e69887c1468eaad377fdbb9b2cbd9e8c032c08c1d119e09dc2c2902ea16f517d51b2b56bc480542d00cd4a0c5487"}],"ComponentSizeInKB":20002,"CompsigList":["CP073301.compsig"],"FileList":["/CP073301_BUILD_2.data","/CP073301.vmexe64","/CP073301.vmfile","/CP073301_VMw.zip","/CP073301.xml","/payload.json","/CP073301_VMw.zip/index.xml","/CP073301_VMw.zip/vendor-index.xml","/CP073301_VMw.zip/metadata.zip","/CP073301_VMw.zip/vib20/CP073301/HPE_bootbank_CP073301_HPG4.2-8.0.0.20613240.vib","/CP073301_VMw.zip/metadata.zip/vendor-index.xml","/CP073301_VMw.zip/metadata.zip/vmware.xml","/CP073301_VMw.zip/metadata.zip/vibs/CP073301--2896074415515272775.xml","/CP073301_VMw.zip/metadata.zip/bulletins/Smart-Component-CP073301_HPG4.2-8.0.0.20613240.xml"],"Name":"CP073301.zip","SHA1Sum":"b865d934fba02a869c16fdb442c381056e3c25c3","SHA256Sum":"373445fba63fd7ca7171f3d225aa83c395eb7d4089c825fb6cb0b227b67151f9","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3830-3030-304757525443"],"TypeOfChange":"1","Version":"HPG4","VibList":[{"Name":"CP073301","Version":"HPG4.2-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB008000GWRTC Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000GWRTC","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0601a954a5a3474eb799f5f5e0","SupportedDevices":["4d2340a5-3042-3830-3030-304757525443"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U30_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u30-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"bad5472efe93e8821e10addeb19e6610eb1f39cd","SHA256Sum":"5b47465b2a2fcb70cc59833f67fe4294165bc967eb518eafe907240907b9a3e9","SHA512Sum":"ea487f5b8cfd8c832d2f424856add2f11200d4cd19f835f42dc56c3b65229d5163f0ab77a4802fa9bd5200cd5d96984ce48a2f625d632e59d34d223c402294cd"}],"ComponentSizeInKB":11598,"CompsigList":["firmware-system-u30-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.70_2026_08_19-1.1/CP073110.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.70_2026_08_19-1.1/U30_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u30-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073110.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073110.scexe"],"Name":"firmware-system-u30-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"bad5472efe93e8821e10addeb19e6610eb1f39cd","SHA256Sum":"5b47465b2a2fcb70cc59833f67fe4294165bc967eb518eafe907240907b9a3e9","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL380 Gen10 (U30) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e3345eb589c64020b1b70a4c7b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","6.0","11.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U30"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EO000400PXDBQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3430-305058444251","Version":"HPD5"},{"DeviceName":"EO000800PXDCK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3030-3830-30505844434b","Version":"HPD5"},{"DeviceName":"EO001600PXDCH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-304f-3130-3630-305058444348","Version":"HPD5"},{"DeviceName":"MO000800PXDBP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-305058444250","Version":"HPD5"},{"DeviceName":"MO001600PXDCC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-305058444343","Version":"HPD5"},{"DeviceName":"MO003200PXDCD","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-305058444344","Version":"HPD5"},{"DeviceName":"MO006400PXDCE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-305058444345","Version":"HPD5"},{"DeviceName":"VO000960PXDBN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30505844424e","Version":"HPD5"},{"DeviceName":"VO001920PXDBR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-305058444252","Version":"HPD5"},{"DeviceName":"VO003840PXDBT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-305058444254","Version":"HPD5"},{"DeviceName":"VO007680PXDBU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305058444255","Version":"HPD5"},{"DeviceName":"VO015300PXDBV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALSHPD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3330-305058444256","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-42aff4675b_0HPD5-2.1_amd64.deb","SHA1Sum":"2e2da8c1f7b7217973c3a25c25ae56e8e8e99cc5","SHA256Sum":"9b5b555e64019a10700a61bff1f9a42ae9e077096a068ff098a910217cfca521","SHA512Sum":"6005afded9e1eebb761adc434f83382fb07be8bdc40c979c8fad8a0f445dbf5d96856a17e20264a5a2fbbcefbddd488497db24d82d88216a4dceb3b24cd399b9"}],"ComponentSizeInKB":4364,"CompsigList":["firmware-hdd-42aff4675b_0HPD5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/CP071771.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/KAPM6ALSHPD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071771.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-42aff4675b-HPD5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071771.scexe"],"Name":"firmware-hdd-42aff4675b_0HPD5-2.1_amd64.deb","SHA1Sum":"2e2da8c1f7b7217973c3a25c25ae56e8e8e99cc5","SHA256Sum":"9b5b555e64019a10700a61bff1f9a42ae9e077096a068ff098a910217cfca521","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-304f-3030-3430-305058444251","452340a5-304f-3030-3830-30505844434b","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3030-3830-305058444250","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3330-3230-305058444344","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3130-3932-305058444252","562340a5-304f-3330-3834-305058444254","562340a5-304f-3730-3638-305058444255","562340a5-304f-3531-3330-305058444256"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EO000400PXDBQ, EO000800PXDCK, EO001600PXDCH, MO000800PXDBP, MO001600PXDCC, MO003200PXDCD, MO006400PXDCE, VO000960PXDBN, VO001920PXDBR, VO003840PXDBT, VO007680PXDBU and VO015300PXDBV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EO000400PXDBQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO000800PXDCK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EO001600PXDCH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800PXDBP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600PXDCC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO003200PXDCD","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO006400PXDCE","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO000960PXDBN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920PXDBR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840PXDBT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680PXDBU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015300PXDBV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0b1fe3d4799f44ddb429596db2","SupportedDevices":["452340a5-304f-3030-3830-30505844434b","4d2340a5-304f-3030-3830-305058444250","452340a5-304f-3030-3430-305058444251","452340a5-304f-3130-3630-305058444348","4d2340a5-304f-3130-3630-305058444343","4d2340a5-304f-3630-3430-305058444345","562340a5-304f-3730-3638-305058444255","562340a5-304f-3130-3932-305058444252","4d2340a5-304f-3330-3230-305058444344","562340a5-304f-3531-3330-305058444256","562340a5-304f-3030-3936-30505844424e","562340a5-304f-3330-3834-305058444254"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A46_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000229","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A46_4.04_04_02_2026.fwpkg","SHA1Sum":"f6eed4c076d70b9f0977f437e600fd19656ed8e5","SHA256Sum":"a03866150b5f927f3f11a58c5582d4cfbeea2b9eb977389ce65c445ec39cccb9","SHA512Sum":"7a3d890ac3026b7e17b2926eab3e6bc18f979310d5c4932997df4389da2a59ac7509026ca86f4a99daf2b42de5e82433229e15d09691baedd98947dfcdf6c84c"}],"ComponentSizeInKB":32810,"CompsigList":[],"FileList":["A46_4.04_04_02_2026.signed.flash","A46_4.04_04_02_2026.xml","payload.json"],"Name":"A46_4.04_04_02_2026.fwpkg","SHA1Sum":"f6eed4c076d70b9f0977f437e600fd19656ed8e5","SHA256Sum":"a03866150b5f927f3f11a58c5582d4cfbeea2b9eb977389ce65c445ec39cccb9","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000229"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant XL225n Gen10 Plus (A46) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d4b6d71390d64a54b23a3a5adc","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A46"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EH000900JWCPN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a5743504e","Version":"HPDB"},{"DeviceName":"EH000600JWCPL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a5743504c","Version":"HPDB"},{"DeviceName":"EH000300JWCPK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a5743504b","Version":"HPDB"},{"DeviceName":"EH000900JXLVU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3930-304a584c5655","Version":"HPDB"},{"DeviceName":"EH000300JXLVR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3330-304a584c5652","Version":"HPDB"},{"DeviceName":"EH000600JXLVT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SKESTNDB.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3048-3030-3630-304a584c5654","Version":"HPDB"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-3d97759111_0HPDB-2.1_amd64.deb","SHA1Sum":"b646f8cdd676047c61f58a07cc2a53830cabd899","SHA256Sum":"77313d55037addd1879aab23f00af053122d999dc3777f5df5000e9e6c4afe00","SHA512Sum":"9caaa537ce76077d2c6ba117ac5ad8748e46e08ceee27e7299622840920b60410642895684c51b006f779ce0788cf495e7d47e42cfc49f5a3dbd64ae9c2e73cf"}],"ComponentSizeInKB":4217,"CompsigList":["firmware-hdd-3d97759111_0HPDB-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/CP071768.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/SKESTNDB.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071768.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-3d97759111-HPDB-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071768.scexe"],"Name":"firmware-hdd-3d97759111_0HPDB-2.1_amd64.deb","SHA1Sum":"b646f8cdd676047c61f58a07cc2a53830cabd899","SHA256Sum":"77313d55037addd1879aab23f00af053122d999dc3777f5df5000e9e6c4afe00","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"TypeOfChange":"1","Version":"HPDB"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - EH000300JWCPK, EH000600JWCPL, EH000900JWCPN, EH000300JXLVR, EH000600JXLVT and EH000900JXLVU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EH000900JWCPN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JWCPL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JWCPK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000900JXLVU","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000300JXLVR","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EH000600JXLVT","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8551199339ce49a099213497fc","SupportedDevices":["452340a5-3048-3030-3330-304a5743504b","452340a5-3048-3030-3630-304a5743504c","452340a5-3048-3030-3930-304a5743504e","452340a5-3048-3030-3930-304a584c5655","452340a5-3048-3030-3330-304a584c5652","452340a5-3048-3030-3630-304a584c5654"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U30","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U30_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000205","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073103.exe","SHA1Sum":"b22dca50cd79f6cbde2ed42846abc428e1d4d54d","SHA256Sum":"c8e67d24314c286b9a425de57c686f7b58f244b2269fa0feb7e2fc72cb46310f","SHA512Sum":"89223b4daa414823cb7b3854f96dd83d1aae6a0aef9587aa9a6036a77e21524285d5ab0edc78a3ed576ef3e767767f846dff2be0cd8ee3c7f9710a12c7a3f9cc"}],"ComponentSizeInKB":11468,"CompsigList":["cp073103.compsig"],"FileList":["cp073103.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U30_3.70_08_19_2026.signed.flash"],"Name":"cp073103.exe","SHA1Sum":"b22dca50cd79f6cbde2ed42846abc428e1d4d54d","SHA256Sum":"c8e67d24314c286b9a425de57c686f7b58f244b2269fa0feb7e2fc72cb46310f","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000205"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL380 Gen10 (U30) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U30","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_005b9c3d6a744719a5b052736c","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U30"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPNTG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3230-3030-304759444e4b","Version":"HPG4"},{"DeviceName":"Seagate-CimarronBP-SATA","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_CimarronBP_SCIMARBPNTG4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-3042-3430-3030-304759445044","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"Seagate_CimarronBP_SCIMARBPNTG4.fwpkg","SHA1Sum":"92e09fe04033bc134c66afaad9fb56d6ec9d690a","SHA256Sum":"fb3716a3647cab1b6e97139a51176141599ca2a43a06efdabed395bc19313127","SHA512Sum":"bb6a5a7fba35c2879c1a257577dc4a7f557d6cafe23937ec615d36c8d4516aafdca3c6ceb9de33d0f3830003c77091cd725a7a4601b133ab4fb62f048a994409"}],"ComponentSizeInKB":2560,"CompsigList":[],"FileList":["payload.json","Seagate_CimarronBP_SCIMARBPNTG4.HPb","Seagate_CimarronBP_SCIMARBPNTG4.xml"],"Name":"Seagate_CimarronBP_SCIMARBPNTG4.fwpkg","SHA1Sum":"92e09fe04033bc134c66afaad9fb56d6ec9d690a","SHA256Sum":"fb3716a3647cab1b6e97139a51176141599ca2a43a06efdabed395bc19313127","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3230-3030-304759444e4b","4d2340a5-3042-3430-3030-304759445044"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MB002000GYDNK and MB004000GYDPD","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB002000GYDNK","SWKeyExpectedPath":"firmware:sd:sata"},{"Name":"MB004000GYDPD","SWKeyExpectedPath":"firmware:sd:sata"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_598a471de19b4292a91b0bdd45","SupportedDevices":["4d2340a5-3042-3230-3030-304759444e4b","4d2340a5-3042-3430-3030-304759445044"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069520.exe","SHA1Sum":"4d93dd4fe118fa8df2dd309c6a6b575e92d6a797","SHA256Sum":"3bfec1080203d7bb7c5f266e65e32ae60589b541f179289698dfe6ed1ac35724","SHA512Sum":"4e75cca08f0b78a7d96d91112eb312b2c5642f325ab8d64fe1c8cd7561e3c296094715c41298e126989a8170a1c9bde5c9ceae7f74c594fa480880942e89381d"}],"ComponentSizeInKB":1054,"CompsigList":["cp069520.compsig"],"FileList":["cp069520.xml","cpqsetup.exe","cp_data.xml","e1r.cat","e1r.inf","e1r.sys","e1rmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp069520.exe","SHA1Sum":"4d93dd4fe118fa8df2dd309c6a6b575e92d6a797","SHA256Sum":"3bfec1080203d7bb7c5f266e65e32ae60589b541f179289698dfe6ed1ac35724","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec743e0890"],"TypeOfChange":"1","Version":"14.0.13.0"}],"InstallationDependency":{},"Name":"HPE Intel E1R Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"e1r.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\e1r.inf_amd64_e973c7f519755373"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1c61d8d675f54d34beb3a14863","SupportedDevices":["a6b1a447-382a-5a4f-8086-1523103c1989","a6b1a447-382a-5a4f-8086-1521159000ff","a6b1a447-382a-5a4f-8086-1521103c337f","a6b1a447-382a-5a4f-8086-1521103c3380","a6b1a447-382a-5a4f-8086-1521103c339e","a6b1a447-382a-5a4f-8086-1521103c17d1","a6b1a447-382a-5a4f-8086-1521103c8157"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020c","Version":"v3.70 (08/19/2026)"},{"DeviceName":"System BIOS - U34","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U34_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000020d","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U34_3.70_08_19_2026.fwpkg","SHA1Sum":"5f7a35ebc0c0154a44c0c95618fb2a8210a10fba","SHA256Sum":"2309b4527e0b5d6678787750e8b1b7202529d75875f511ca0aa9f3e2be311930","SHA512Sum":"87333b0f674041ede361c60c1ef9f0f9b759b1d7f10cc33ec352c4bdc15e0156e2c8893773df43330f6a800e9f513e2c7241872917883bf5a5a2c31d6f5d31e8"}],"ComponentSizeInKB":32828,"CompsigList":[],"FileList":["payload.json","U34_3.70_08_19_2026.signed.flash","U34_3.70_08_19_2026.xml"],"Name":"U34_3.70_08_19_2026.fwpkg","SHA1Sum":"5f7a35ebc0c0154a44c0c95618fb2a8210a10fba","SHA256Sum":"2309b4527e0b5d6678787750e8b1b7202529d75875f511ca0aa9f3e2be311930","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000020c","00000000-0000-0000-0000-00000000020d"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL560 Gen10/DL580 Gen10 (U34) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U34","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d4294c15f2194a80a36882ce8e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.0","6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - Lights-Out Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070206.exe","SHA1Sum":"30b92cb52bc7a9403c69ed8760ea367d8a09dd48","SHA256Sum":"192489a2cd5bd00df8d2d09c449d109d5a59d7a262ce8662f6eb338a22aa676e","SHA512Sum":"dade1466ad72044b032095889d5e1d37be7573787c6a5e75492d06a8dc854ba2c6ebe8e00234a41cd887bf35fd096abd70f19175d2a214bf3d93839bb1f53783"}],"ComponentSizeInKB":1227,"CompsigList":["cp070206.compsig"],"FileList":["cp070206.xml","cpqsetup.exe","hponcfg.dll","hponcfg.msi"],"Name":"cp070206.exe","SHA1Sum":"30b92cb52bc7a9403c69ed8760ea367d8a09dd48","SHA256Sum":"192489a2cd5bd00df8d2d09c449d109d5a59d7a262ce8662f6eb338a22aa676e","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6b3a6f74"],"TypeOfChange":"0","Version":"6.0.0.0"}],"InstallationDependency":{},"Name":"HPE Lights-Out Online Configuration Utility for Windows x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":100,"RebootRequired":"no","SWKeys":[{"Name":"hponcfg.exe","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\HPONCFG"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2e68cf7c5c944e8dac3a1c14e1","SupportedDevices":["a6b1a447-382a-5a4f-0e11-b2040e11b206","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306103c3381","a6b1a447-382a-5a4f-103c-3307103c3381","a6b1a447-382a-5a4f-103c-3308103c3381","a6b1a447-382a-5a4f-103c-3300103c3381","a6b1a447-382a-5a4f-103c-3301103c3381","a6b1a447-382a-5a4f-103c-3302103c3381","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-33061590027f","a6b1a447-382a-5a4f-103c-33071590027f","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.2","6.2","6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["I38","I32","A26","I41","I36","I31","I30","U34","U17","P79","U34","P85","P77","P89","A42","A40","A28","U46","U30","P89","P70","P73","A42","U46","U32","P89","P71","P73","A43","A43","A43","A41","P80","J05","U31","U20","U31","U20","J03","U36","P86","U15","U15","U43","U22","U41","P92","P72","J02","P78","J04","HPE ProLiant ML150 Gen10 Server","P95","U33","P99","U44","U23","O42","J10","P88","P74","P75","P75","P75","P75","P83","U51","U18","U18","U18","A47","A48","U40","U21","U50","U39","U47","U45","U25","U24","U24","U13","U37","U13","A46","U47","P94","A48","U38","U14","U38","U14","U48","O43","J06","U26","I36","I31","A45","U38","U38","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","U38","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U47","U47","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","Carbondale14","Carbondale14","U40","Carbondale14","U50","U39","U19","U46","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","I40","I43","I39","I40","I45","I44","I42","I37","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U64","U58","R11","U65","U65","U65","H11","U69","A58","I15","P64","W04","U14","HP StorageWorks 1200 All-in-One Storage System","HP StorageWorks 600 All-in-One Storage System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"libbnxt_re-238.1.165.0-rhel9u8.x86_64.rpm","SHA1Sum":"5329a15a1651c63d78ff2aab413c575d87e7a8c4","SHA256Sum":"c4d75271ce3d22c0b1cc490a602d18ea97929213078fcc875c62213c87889602","SHA512Sum":"23fc138d46224fa64eb6f8e11795b312f8a47b13268d52e74bc26b4c522fd0924665251594a731b9916cba70ef072afc47961bee97afe934987c1888780eaac6"}],"ComponentSizeInKB":64,"CompsigList":["libbnxt_re-238.1.165.0-rhel9u8.x86_64.compsig"],"FileList":["./etc/libibverbs.d/bnxt_re.driver","./usr/lib/.build-id","./usr/lib/.build-id/ae","./usr/lib/.build-id/ae/a27530fba114a5925e9d342924da727701a74a","./usr/lib64/libbnxt_re-238.1.165.0.so","./usr/lib64/libbnxt_re-rdmav59.so","./usr/lib64/libbnxt_re.so","./usr/lib64/pkgconfig/libbnxt_re.pc","./usr/share/smartupdate/libbnxt_re/component.xml"],"Name":"libbnxt_re-238.1.165.0-rhel9u8.x86_64.rpm","SHA1Sum":"5329a15a1651c63d78ff2aab413c575d87e7a8c4","SHA256Sum":"c4d75271ce3d22c0b1cc490a602d18ea97929213078fcc875c62213c87889602","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff04767d"],"TypeOfChange":"1","Version":"238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E RoCE Library for Red Hat Enterprise Linux 9 Update 8.","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"libbnxt_re","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0c5d9c9c61cf4276ab2c40b4a8","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069549.exe","SHA1Sum":"bebf37bcee88bd5bdf3a20b720e7ec020f97626d","SHA256Sum":"a81f4073aef93752777eccaf61efe595c00ac50cc335a13c1485739263db2f41","SHA512Sum":"1962a25d2107584cf94633174681f88eb3ee67fbcb69e759a5217a4edc8713098f303e92e9d985d50158b9263c9fffbb29203c4e04a13086bbc91b7fdcd6f8ca"}],"ComponentSizeInKB":1017,"CompsigList":["cp069549.compsig"],"FileList":["cp069549.xml","cpqsetup.exe","cp_data.xml","install.xml","ixn68x64.cat","ixn68x64.din","ixn68x64.inf","ixn68x64.sys","ixnmsg.dll","nicdrvr.dll"],"Name":"cp069549.exe","SHA1Sum":"bebf37bcee88bd5bdf3a20b720e7ec020f97626d","SHA256Sum":"a81f4073aef93752777eccaf61efe595c00ac50cc335a13c1485739263db2f41","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec619e0b4b"],"TypeOfChange":"1","Version":"4.1.254.0"}],"InstallationDependency":{},"Name":"HPE Intel ixn Driver for Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"ixn68x64.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0c703a78e2174310a9807b7cb6","SupportedDevices":["a6b1a447-382a-5a4f-8086-10fb103c17d0","a6b1a447-382a-5a4f-8086-10fb103c17d3"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VK003840GWSXL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"M52004TBHPG4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304b-3330-3834-30475753584c","Version":"HPG4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-d1cf327bc4-HPG4-1.1.x86_64.rpm","SHA1Sum":"f6c7b581b604132e62172580baefe536875b7312","SHA256Sum":"9f4034ffa2a7ed4d2dbe9bcfbecbd10356efa30f9f1b2513ffea04f9b10cfbc2","SHA512Sum":"f373f8315e309f8aae0cedcf882075f4d8fcbdf731fbe34bba997c14a0c2c94f681d270fea82ddf8c3638243a4e1dbeeefa61fdf2fd14a1abad0abedfd433295"}],"ComponentSizeInKB":5151,"CompsigList":["firmware-hdd-d1cf327bc4-HPG4-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/CP072133.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/M52004TBHPG4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-d1cf327bc4-HPG4-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072133.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072133.scexe"],"Name":"firmware-hdd-d1cf327bc4-HPG4-1.1.x86_64.rpm","SHA1Sum":"f6c7b581b604132e62172580baefe536875b7312","SHA256Sum":"9f4034ffa2a7ed4d2dbe9bcfbecbd10356efa30f9f1b2513ffea04f9b10cfbc2","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304b-3330-3834-30475753584c"],"TypeOfChange":"1","Version":"HPG4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VK003840GWSXL Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VK003840GWSXL","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c10a36f93d7a4edd8c0659437e","SupportedDevices":["562340a5-304b-3330-3834-30475753584c"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp071446.exe","SHA1Sum":"8df0bc66f7ccfc9b1835a62c27243452456b7ebf","SHA256Sum":"a06b30fd5f1dece7e902e98dac74285fe4fce5ce23c442b494c635572b813ccc","SHA512Sum":"54ed2e45f88c988d996259e8cf9fee28ca980555295864a108d540e72b45d27c0c13f38f0de964f0764781c33073888a2bc312be1b173c79ed463a7af6064c78"}],"ComponentSizeInKB":53938,"CompsigList":["cp071446_part1.compsig","cp071446_part2.compsig"],"FileList":["cp071446.xml","cpqsetup.exe","cp_data.xml","HPE_Windows_readme.txt","install.xml","ISSetupPrerequisites/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/","ISSetupPrerequisites/{7f66a156-bc3b-479d-9703-65db354235cc}/vcredist_x64.exe","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/","ISSetupPrerequisites/{D093EE4D-527D-4CC7-AB3C-DCE3219FA508}/vc_redist.x64.exe","multisetup.dll","setup.exe"],"Name":"cp071446.exe","SHA1Sum":"8df0bc66f7ccfc9b1835a62c27243452456b7ebf","SHA256Sum":"a06b30fd5f1dece7e902e98dac74285fe4fce5ce23c442b494c635572b813ccc","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecf81a7df0"],"TypeOfChange":"1","Version":"8.18.11.0"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator for Windows 64-bit (HPE MRSA for MR Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"lsa.exe","SWKeyExpectedPath":"%programfiles%\\HPEMRSA\\LSIStorageAuthority\\bin"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1673b76290904424a7eea2247b","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448","a6b1a447-382a-5a4f-1000-00b315900453"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U58","U63","U54","U54","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"lsi-megaraid_sas-kmp-default-07.738.06.0_sles16sp0-1.x86_64.rpm","SHA1Sum":"177bf8dbb2fa38afda048a82c53914d71fa2db10","SHA256Sum":"709efa855e8430161d82731465bf0a9539d1dd14dde6ddd4b6442eeea0f29bdf","SHA512Sum":"f1c50e14df1405ee8691b0d9d57d5486cca493470814c935f27e2b98c487133d8a5f3c70ad8b3945150ed304e42cd8dbc5173d31f497aeadd2c3ffc90d03ea57"}],"ComponentSizeInKB":912,"CompsigList":["lsi-megaraid_sas-kmp-default-07.738.06.0_sles16sp0-1.x86_64.compsig"],"FileList":["./usr/lib/.build-id","./usr/lib/.build-id/b7","./usr/lib/.build-id/b7/5c1aa60393774c36a324a16221828184c363d9","./usr/lib/modules/6.12.0-160000.5-default","./usr/lib/modules/6.12.0-160000.5-default/updates","./usr/lib/modules/6.12.0-160000.5-default/updates/megaraid_sas.ko","./usr/share/smartupdate/lsi-megaraid_sas-kmp-default/component.xml"],"Name":"lsi-megaraid_sas-kmp-default-07.738.06.0_sles16sp0-1.x86_64.rpm","SHA1Sum":"177bf8dbb2fa38afda048a82c53914d71fa2db10","SHA256Sum":"709efa855e8430161d82731465bf0a9539d1dd14dde6ddd4b6442eeea0f29bdf","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5257f12b"],"TypeOfChange":"1","Version":"07.738.06.0"}],"InstallationDependency":{},"Name":"HPE MR416i-p, MR216i-p, MR416i-a, MR216i-a Gen10 plus and MR416i-p, MR416i-o, MR216i-o, MR408i-o, MR216i-p, MR408i-p Gen11 controllers Driver for 64-bit SUSE LINUX Enterprise Server 16","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"lsi-megaraid_sas-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1e6a74e236a048cebc630bd8f5","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U58","U54","U58","U63","U54","U54","U61","U60","U46","U30","U32","A42","A43","A43","A42","U59","U63","U46","U65","U65","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","A59","A66","U71","A72","A66","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":2,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_322.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"9c057a7a-0d48-4260-b033-558f22ef7c6a","Version":"3.22"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_322.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c5b14abd-6d2f-41d7-b665-0447dfdac3a7","Version":"3.22"},{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_322.bin","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"c0bcf2b9-1141-49af-aab8-c73791f0349c","Version":"3.22"}]},"Files":[{"Checksum":[{"Filename":"cp072782.exe","SHA1Sum":"6a6aeaf7bed990f4f66ca9c9ba000a6e43ba89aa","SHA256Sum":"80011b326d31ffd42ee7ed79f5b295722b537cd606d7ea91da4b8249aeb28d9c","SHA512Sum":"659a3d9a2a3ff9e715463971f34038b64011d712aefafa26b8db351eede92db389b6c51cf69cfa4e2d810c6d4b7a04ba92d22c87fa1acd8fa6c96c6b0bb0b2fb"}],"ComponentSizeInKB":33463,"CompsigList":["cp072782_part1.compsig","cp072782_part2.compsig"],"FileList":["cp072782.xml","cpqsetup.exe","ilo5_322.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"Name":"cp072782.exe","SHA1Sum":"6a6aeaf7bed990f4f66ca9c9ba000a6e43ba89aa","SHA256Sum":"80011b326d31ffd42ee7ed79f5b295722b537cd606d7ea91da4b8249aeb28d9c","SoftwarePlatforms":[],"TargetGUIDs":["9c057a7a-0d48-4260-b033-558f22ef7c6a","c5b14abd-6d2f-41d7-b665-0447dfdac3a7","c0bcf2b9-1141-49af-aab8-c73791f0349c"],"TypeOfChange":"1","Version":"3.22"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4a233e6dcf6e414aa1b08604b0","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3307159000e4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0","6.1","6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U51","A47","A48","U40","U39","U47","U45","U24","U37","A46","U47","U38","U38","U48","O43","A45","U38","U38","U38","U47","U47","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U40","U50","U39","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","I43","I44","I42","A42","U56","H10","U61","U60","U64","H10","H10"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MZXL5800HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3830-3048d90154e8","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T6HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-36487a9b1618","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T2HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-324884d9e9f5","Version":"MPK78H5Q"},{"DeviceName":"MZXL56T4HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3654-34482ab7fb8f","Version":"MPK78H5Q"},{"DeviceName":"MZXL512THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3132-544895b51a17","Version":"MPK78H5Q"},{"DeviceName":"MZXL5960HBHQ-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3936-304894dc03d2","Version":"MPK78H5Q"},{"DeviceName":"MZXL51T9HBJR-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3154-3948e450274f","Version":"MPK78H5Q"},{"DeviceName":"MZXL53T8HBLS-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3354-38483310a47b","Version":"MPK78H5Q"},{"DeviceName":"MZXL57T6HALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3754-364820f1a5c1","Version":"MPK78H5Q"},{"DeviceName":"MZXL515THALA-000H3","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MPK78H5Q.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-585a-354c-3135-54486d0092b3","Version":"MPK78H5Q"}]},"Files":[{"Checksum":[{"Filename":"cp068633.exe","SHA1Sum":"9db736246b59c83f06d19cf3299613b7f2c9a9df","SHA256Sum":"81d606c783a1d6f4c2438b144fed52cd7f930f4785982d83fedb517cea26cfc7","SHA512Sum":"901e1801e4629a93b264c4c74a9240903b7c9b18b5dee34691d717e3feea2841cd4ccb1317e51840bc048d0522c02d37b939c809827551fef387aedc63b9e8c4"}],"ComponentSizeInKB":7821,"CompsigList":["cp068633.compsig"],"FileList":["cp068633.xml","cpqsetup.exe","mnv_cli.exe","MPK78H5Q.rel","payload.json","setup.dll"],"Name":"cp068633.exe","SHA1Sum":"9db736246b59c83f06d19cf3299613b7f2c9a9df","SHA256Sum":"81d606c783a1d6f4c2438b144fed52cd7f930f4785982d83fedb517cea26cfc7","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3154-3948e450274f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3135-54486d0092b3"],"TypeOfChange":"1","Version":"MPK78H5Q"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Windows (x64) - MZXL5800HBHQ-000H3, MZXL51T6HBJR-000H3, MZXL53T2HBLS-000H3, MZXL56T4HALA-000H3, MZXL512THALA-000H3, MZXL5960HBHQ-000H3, MZXL51T9HBJR-000H3, MZXL53T8HBLS-000H3, MZXL57T6HALA-000H3 and MZXL515THALA-0 Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MZXL5800HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T6HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T2HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL56T4HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL512THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL5960HBHQ-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL51T9HBJR-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL53T8HBLS-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL57T6HALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MZXL515THALA-000H3","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e41a30bd00ab4b4ba56cdbac8a","SupportedDevices":["4d2340a5-585a-354c-3936-304894dc03d2","4d2340a5-585a-354c-3135-54486d0092b3","4d2340a5-585a-354c-3132-544895b51a17","4d2340a5-585a-354c-3754-364820f1a5c1","4d2340a5-585a-354c-3654-34482ab7fb8f","4d2340a5-585a-354c-3354-38483310a47b","4d2340a5-585a-354c-3354-324884d9e9f5","4d2340a5-585a-354c-3154-36487a9b1618","4d2340a5-585a-354c-3830-3048d90154e8","4d2340a5-585a-354c-3154-3948e450274f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A47","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A47_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"A47_4.04_04_02_2026.fwpkg","SHA1Sum":"a64a1b1a8d8ced5c606df19b4f7c02148bf8d39b","SHA256Sum":"39594a94d7311489639f02c68bb765003ac0862d12854f7450471bb5df295e90","SHA512Sum":"e60901fd46803e2c412e7a972fbe6f797b6c929c78eabd40901a2bfa4d42fa46ca6310de1f4f7dacdfaa45e8cc4444ed0cf5e1dea3ca8fd64a2a17325d41d4cf"}],"ComponentSizeInKB":32808,"CompsigList":[],"FileList":["A47_4.04_04_02_2026.signed.flash","A47_4.04_04_02_2026.xml","payload.json"],"Name":"A47_4.04_04_02_2026.fwpkg","SHA1Sum":"a64a1b1a8d8ced5c606df19b4f7c02148bf8d39b","SHA256Sum":"39594a94d7311489639f02c68bb765003ac0862d12854f7450471bb5df295e90","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000022d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Universal Firmware Package - HPE Apollo 6500 Gen10 Plus/HPE ProLiant XL675d Gen10 Plus (A47) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A47","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b9b0cf04bcc24d55b2f6124f56","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A47","HPE Apollo 6500 Gen10 Plus (Chassis)"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssaducli-6.65-9.0_amd64.deb","SHA1Sum":"54f071273116265e77f50ee4450cc780e608bcd1","SHA256Sum":"fcdfc8cfb5b56467560f7cf74f4dbf67358fbbfee1241a9f187efdaac9296329","SHA512Sum":"ade150830bed3a780fe7697ba060f2362b1e501e3babba12a336e30b81425b2278318462d29636f82986aa46db43f3dd5518ca5b7bf0a539bfc44266b03a7e9b"}],"ComponentSizeInKB":2816,"CompsigList":["ssaducli-6.65-9.0_amd64.compsig"],"FileList":["./opt/smartstorageadmin/ssaducli/README.TXT","./opt/smartstorageadmin/ssaducli/bin/ssaducli","./opt/smartstorageadmin/ssaducli/bin/ssaduesxi","./opt/smartstorageadmin/ssaducli/bin/upgrade.txt","./opt/smartstorageadmin/ssaducli/ssadu.license","./usr/sbin/ssaducli","./usr/share/doc/ssaducli/changelog.Debian.gz","./usr/share/doc/ssaducli/copyright","./usr/share/man/man8/ssaducli.8.gz","./usr/share/smartupdate/ssaducli/component.xml"],"Name":"ssaducli-6.65-9.0_amd64.deb","SHA1Sum":"54f071273116265e77f50ee4450cc780e608bcd1","SHA256Sum":"fcdfc8cfb5b56467560f7cf74f4dbf67358fbbfee1241a9f187efdaac9296329","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec9fb103be"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator Diagnostic Utility (SSADU) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssaducli","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_394e276358864ea9a2e47f1143","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A47","A48","U47","A46","U47","I44","U63","I45","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","U14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","Carbondale14","U19","Carbondale14","Carbondale14","I40","I37","I39","I40","U57","U65","U62","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB010000JWZHA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3031-3030-304a575a4841","Version":"HPD4"},{"DeviceName":"MB012000JWZHB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a575a4842","Version":"HPD4"},{"DeviceName":"MB014000JWZHC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a575a4843","Version":"HPD4"},{"DeviceName":"MB016000JWZHE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SHPEEVANSSD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a575a4845","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-cf0b6cabe1-HPD4-7.1.x86_64.rpm","SHA1Sum":"515b9ebcc8c5757af109f083e33fb11bf9893f05","SHA256Sum":"67284f4ff7c7f67c7f7977ab7f4a3561e40dc36633e57443400935af765847d6","SHA512Sum":"302268edc3cbc18e1a14c3de472bf1de61bcff54e996e19385555964670560552d64e575c801df41300490d8be952dfcd6011b0ae04dd3e75f3c76a7bd8e9681"}],"ComponentSizeInKB":6096,"CompsigList":["firmware-hdd-cf0b6cabe1-HPD4-7.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/CP068803.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/SHPEEVANSSD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-cf0b6cabe1-HPD4-7.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068803.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068803.scexe"],"Name":"firmware-hdd-cf0b6cabe1-HPD4-7.1.x86_64.rpm","SHA1Sum":"515b9ebcc8c5757af109f083e33fb11bf9893f05","SHA256Sum":"67284f4ff7c7f67c7f7977ab7f4a3561e40dc36633e57443400935af765847d6","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3231-3030-304a575a4842","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3631-3030-304a575a4845"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB010000JWZHA, MB012000JWZHB, MB014000JWZHC and MB016000JWZHE Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB010000JWZHA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB012000JWZHB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JWZHC","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JWZHE","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c412afec4b864fbe9252ae577a","SupportedDevices":["4d2340a5-3042-3031-3030-304a575a4841","4d2340a5-3042-3631-3030-304a575a4845","4d2340a5-3042-3431-3030-304a575a4843","4d2340a5-3042-3231-3030-304a575a4842"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"IEGen10Plus_1.0.0.22.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-87800a000303","Version":"1.0.0.22"}]},"Files":[{"Checksum":[{"Filename":"IEGen10Plus_1.0.0.22.fwpkg","SHA1Sum":"e743961dc9a51f5b0e59a516726ea8ee82d791f1","SHA256Sum":"f4b0c7da665d0f2f3e76e22a49c010fac744ce1c04327f9462c3e9bb617fd2eb","SHA512Sum":"45b8552f3709e3e0db33df6d1128e37cdc3a1ed26a2f25fb448a7f26944931cdbb46862c72474b71ecabba001baa053da764a31fd005a2b27f36da3a49212aa5"}],"ComponentSizeInKB":8212,"CompsigList":[],"FileList":["IEGen10Plus_1.0.0.22.signed.bin","IEGen10Plus_1.0.0.22.xml","payload.json"],"Name":"IEGen10Plus_1.0.0.22.fwpkg","SHA1Sum":"e743961dc9a51f5b0e59a516726ea8ee82d791f1","SHA256Sum":"f4b0c7da665d0f2f3e76e22a49c010fac744ce1c04327f9462c3e9bb617fd2eb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-87800a000303"],"TypeOfChange":"1","Version":"1.0.0.22"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - HPE Gen10 Plus Innovation Engine Firmware for HPE Gen10 Plus Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10Plus","SWKeyExpectedPath":"firmware:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5ba2fe62306d406aae00e29952","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U46","U46","U47","U47","U50","I44","H10","U56","H10","H10","U46"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVLAWBA0HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"cp073205.exe","SHA1Sum":"39b31a45417f58c5688213b26dd473e21ea4ea5f","SHA256Sum":"b44e2c4255e6f98cc5f5bfc625e1d03aaad8ab3eff11a13ebe9b459c1aad0a37","SHA512Sum":"f0937335452618dd671bf75f307655b6cdc0d4ed86d18de488786450d1da159efbd87adfd95fe3d795a15eab1bab736c0bfa7e1fb753019679d9146acfc1eb74"}],"ComponentSizeInKB":4467,"CompsigList":["cp073205.compsig"],"FileList":["cp073205.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","WVLAWBA0HPG5.rel"],"Name":"cp073205.exe","SHA1Sum":"39b31a45417f58c5688213b26dd473e21ea4ea5f","SHA256Sum":"b44e2c4255e6f98cc5f5bfc625e1d03aaad8ab3eff11a13ebe9b459c1aad0a37","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB004000GWKGV Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c833a9e195224ccf8c7960ba12","SupportedDevices":["4d2340a5-3042-3430-3030-3047574b4756"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"CP070963.zip","SHA1Sum":"c6c04a55208609bfb337a7fa4efc895ca4371821","SHA256Sum":"b2a458d0a3d871c816658ca00d3c960bc43feccadcb0c245acf9366f79c33115","SHA512Sum":"8a3f737edf38f7b82c65459dc6d43dd9a36daa9de2b17b4a5cadbaabd16e2297ce69f815b151654a4525fd62749bda4196d6d5df5fb3c4e695aabae13665ca52"}],"ComponentSizeInKB":21737,"CompsigList":["CP070963.compsig"],"FileList":["/CP070963_BUILD_1.data","/CP070963.vmexe64","/CP070963.vmfile","/CP070963_VMw.zip","/CP070963.xml","/payload.json","/CP070963_VMw.zip/index.xml","/CP070963_VMw.zip/vendor-index.xml","/CP070963_VMw.zip/metadata.zip","/CP070963_VMw.zip/vib20/CP070963/HPE_bootbank_CP070963_HPD3.1-8.0.0.20613240.vib","/CP070963_VMw.zip/metadata.zip/vendor-index.xml","/CP070963_VMw.zip/metadata.zip/vmware.xml","/CP070963_VMw.zip/metadata.zip/vibs/CP070963-4749097202626109637.xml","/CP070963_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070963_HPD3.1-8.0.0.20613240.xml"],"Name":"CP070963.zip","SHA1Sum":"c6c04a55208609bfb337a7fa4efc895ca4371821","SHA256Sum":"b2a458d0a3d871c816658ca00d3c960bc43feccadcb0c245acf9366f79c33115","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3","VibList":[{"Name":"CP070963","Version":"HPD3.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB016000JXLBA and MB018000JXLAU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f64e39d61624d1ab3a445de00","SupportedDevices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp070629.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"firmware-ml30gen10plus_me-06.00.03.708-3.1.x86_64.rpm","SHA1Sum":"88d50ac2661fe7f0f151cab4f11c85b169390a95","SHA256Sum":"82e0b42526ad4e422f3d203c87932cdbc332b1164ac480649b09d12d20d3853c","SHA512Sum":"49922bb3b7e3b73a6761871266a8f0ff306b12b7f2382a8281c3c34e8598c38457ccaae08874a2a501a3f1dad34794a0055beb801e7d3bfece7e14f38912d66e"}],"ComponentSizeInKB":2400,"CompsigList":["firmware-ml30gen10plus_me-06.00.03.708-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/CP070632.xml","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/cp070629.compsig","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/cp070629.zip","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ml30gen10plus_me-06.00.03.708-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070632.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070632.scexe"],"Name":"firmware-ml30gen10plus_me-06.00.03.708-3.1.x86_64.rpm","SHA1Sum":"88d50ac2661fe7f0f151cab4f11c85b169390a95","SHA256Sum":"82e0b42526ad4e422f3d203c87932cdbc332b1164ac480649b09d12d20d3853c","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7ea1377b0d2b4dada100454a81","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000GWKGV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVLAWBA0HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-3047574b4756","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"CP073208.zip","SHA1Sum":"a2b3ad98021a600fb1b4d35d5dd21a8f8a23287e","SHA256Sum":"918e4a72d45c1e01d2f510784c0030b6a2ed34c6a21d3ed6db5ba8f125779934","SHA512Sum":"e0661e7a769020f1d978524fcc72b39a3885504386784813b53410674fe49cd934a0a9900d4c6d90eb45756aabe9dbce8139b2fa128c0845d2b36bf25df1be36"}],"ComponentSizeInKB":20233,"CompsigList":["CP073208.compsig"],"FileList":["/CP073208_BUILD_1.data","/CP073208.vmexe64","/CP073208.vmfile","/CP073208_VMw.zip","/CP073208.xml","/payload.json","/CP073208_VMw.zip/index.xml","/CP073208_VMw.zip/vendor-index.xml","/CP073208_VMw.zip/metadata.zip","/CP073208_VMw.zip/vib20/CP073208/HPE_bootbank_CP073208_HPG5.1-8.0.0.20613240.vib","/CP073208_VMw.zip/metadata.zip/vendor-index.xml","/CP073208_VMw.zip/metadata.zip/vmware.xml","/CP073208_VMw.zip/metadata.zip/vibs/CP073208--5147559363019412867.xml","/CP073208_VMw.zip/metadata.zip/bulletins/Smart-Component-CP073208_HPG5.1-8.0.0.20613240.xml"],"Name":"CP073208.zip","SHA1Sum":"a2b3ad98021a600fb1b4d35d5dd21a8f8a23287e","SHA256Sum":"918e4a72d45c1e01d2f510784c0030b6a2ed34c6a21d3ed6db5ba8f125779934","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3430-3030-3047574b4756"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP073208","Version":"HPG5.1-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB004000GWKGV Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000GWKGV","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_91075907096b4e4891de2278c5","SupportedDevices":["4d2340a5-3042-3430-3030-3047574b4756"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp070622.zip","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"firmware-dl20gen10plus_me-06.00.03.708-3.1.x86_64.rpm","SHA1Sum":"a87af09c10680356ebc7c8ea69f6939b4bf5d6e1","SHA256Sum":"15d5bdb9b1877d1f6b111226eb078fe3bcaf07123c96ccb825e7015b4937ecfb","SHA512Sum":"3b7a464953ecd1f15ffd0cb4c712195b0b2450b3848b56a251d3ec47feb137e8c7084b56081847026db8002e8dbd1a4750ec1611f4830e0c05e2f12698b33254"}],"ComponentSizeInKB":2400,"CompsigList":["firmware-dl20gen10plus_me-06.00.03.708-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/CP070625.xml","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/cp070622.compsig","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/cp070622.zip","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-dl20gen10plus_me-06.00.03.708-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP070625.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP070625.scexe"],"Name":"firmware-dl20gen10plus_me-06.00.03.708-3.1.x86_64.rpm","SHA1Sum":"a87af09c10680356ebc7c8ea69f6939b4bf5d6e1","SHA256Sum":"15d5bdb9b1877d1f6b111226eb078fe3bcaf07123c96ccb825e7015b4937ecfb","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash for Linux - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9688f993fe7c4aacb645c85290","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3936-30525852514b","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3932-305258525248","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3834-30525852524b","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-30525852514c","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-30525852524c","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30525852524e","Version":"HPD4"},{"DeviceName":"Seagate-Cooper-SAS","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Seagate_Cooper_SCOOPRHPESD4.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-305259455744","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"Seagate_Cooper_SCOOPRHPESD4.fwpkg","SHA1Sum":"c8c2de7eb0c933f9dbc8b7b1e3cc6431417575bb","SHA256Sum":"a3bb0d6882d2d7257baebff8739de96a46b3a33f2e59ab5c03bbaa36456ec006","SHA512Sum":"4079f4c67efc5491e13b6fe47e415d6d9be5b0fd29bf58ce4295c9b885bd4a07d52c7e387f52d8f53ea4bbd277c817b366c1ba26a214fa3ac5a7b6befe002ef6"}],"ComponentSizeInKB":2091,"CompsigList":[],"FileList":["payload.json","Seagate_Cooper_SCOOPRHPESD4.HPb","Seagate_Cooper_SCOOPRHPESD4.xml"],"Name":"Seagate_Cooper_SCOOPRHPESD4.fwpkg","SHA1Sum":"c8c2de7eb0c933f9dbc8b7b1e3cc6431417575bb","SHA256Sum":"a3bb0d6882d2d7257baebff8739de96a46b3a33f2e59ab5c03bbaa36456ec006","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3936-30525852514b","4d2340a5-304f-3130-3932-305258525248","4d2340a5-304f-3330-3834-30525852524b","562340a5-304f-3030-3936-30525852514c","562340a5-304f-3130-3932-30525852524c","562340a5-304f-3330-3834-30525852524e","562340a5-304f-3730-3638-305259455744"],"TypeOfChange":"2","Version":"HPD4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO000960RXRQK, MO001920RXRRH, MO003840RXRRK, VO000960RXRQL, VO001920RXRRL, VO003840RXRRN and VO007680RYEWD","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000960RXRQK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO001920RXRRH","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"MO003840RXRRK","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO000960RXRQL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO001920RXRRL","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO003840RXRRN","SWKeyExpectedPath":"firmware:sd:sas"},{"Name":"VO007680RYEWD","SWKeyExpectedPath":"firmware:sd:sas"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_351d50a2bba345ebbd72893c5d","SupportedDevices":["4d2340a5-304f-3030-3936-30525852514b","4d2340a5-304f-3130-3932-305258525248","4d2340a5-304f-3330-3834-30525852524b","562340a5-304f-3030-3936-30525852514c","562340a5-304f-3130-3932-30525852524c","562340a5-304f-3330-3834-30525852524e","562340a5-304f-3730-3638-305259455744"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","7.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000JZYVN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304a5a59564e","Version":"HPD6"},{"DeviceName":"MB014000JZYVP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3431-3030-304a5a595650","Version":"HPD6"},{"DeviceName":"MB016000JZYVQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a5a595651","Version":"HPD6"},{"DeviceName":"MB018000JYCLK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG09scHPD6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a59434c4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-87b796d9ae_0HPD6-2.1_amd64.deb","SHA1Sum":"3640a936651345a24a49135f4a1993456e6c47de","SHA256Sum":"6fe73bee1dfc0b4855a83263d816d7b3840b128956123d523317c3bd2e8f71af","SHA512Sum":"6bd5b4378a393a550ec008e277bcb0152893f0d7bc6f5d5ca70f200d2a15e3b44590e84466755f1e931deb2c3ed94b9a0ef841914c960bb719085648e8825fb3"}],"ComponentSizeInKB":4525,"CompsigList":["firmware-hdd-87b796d9ae_0HPD6-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/CP071791.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/TAMG09scHPD6.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071791.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-87b796d9ae-HPD6-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071791.scexe"],"Name":"firmware-hdd-87b796d9ae_0HPD6-2.1_amd64.deb","SHA1Sum":"3640a936651345a24a49135f4a1993456e6c47de","SHA256Sum":"6fe73bee1dfc0b4855a83263d816d7b3840b128956123d523317c3bd2e8f71af","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB012000JZYVN, MB014000JZYVP, MB016000JZYVQ and MB018000JYCLK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000JZYVN","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB014000JZYVP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB016000JZYVQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JYCLK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f387cbf83e2d4e268bc0acb71f","SupportedDevices":["4d2340a5-3042-3231-3030-304a5a59564e","4d2340a5-3042-3431-3030-304a5a595650","4d2340a5-3042-3631-3030-304a5a595651","4d2340a5-3042-3831-3030-304a59434c4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWKGR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL6WBA0HPG5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574b4752","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-7f2a26e6d0_0HPG5-2.1_amd64.deb","SHA1Sum":"0979ea6723f700dccebf41cf41a14765c423197e","SHA256Sum":"f5b8af7a231cffabff569ca561d0b24e10e63b0eef6fa6a6a10713c63c6d43ed","SHA512Sum":"54e391d3ac491212a5b300919b88de295cde379b9dd2e0ddf0066e70aa1a57f39570d795a28b5e57b9e32506a84c72cc24888a8a539b680d651348e4791d2f0d"}],"ComponentSizeInKB":4689,"CompsigList":["firmware-hdd-7f2a26e6d0_0HPG5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/CP073212.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/WVL6WBA0HPG5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073212.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-7f2a26e6d0-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073212.scexe"],"Name":"firmware-hdd-7f2a26e6d0_0HPG5-2.1_amd64.deb","SHA1Sum":"0979ea6723f700dccebf41cf41a14765c423197e","SHA256Sum":"f5b8af7a231cffabff569ca561d0b24e10e63b0eef6fa6a6a10713c63c6d43ed","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574b4752"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB006000GWKGR Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWKGR","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5b8ed6c3d898439380d5345a89","SupportedDevices":["4d2340a5-3042-3630-3030-3047574b4752"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u2.x86_64.rpm","SHA1Sum":"fdbdf7934187530dfa39965103b7f430b4affd87","SHA256Sum":"5d2576906306ea933575c6765957000e488707de8babec34e2f19168379ad6c5","SHA512Sum":"d9fd879fceee31d2185a856968b5e5dad40de5aaa7900565ee1a740b8189abb4462e5b58ae0b7ed8ddef40808092b6742dce0418ba1200990b55b83aec326f31"}],"ComponentSizeInKB":1439,"CompsigList":["kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"Name":"kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u2.x86_64.rpm","SHA1Sum":"fdbdf7934187530dfa39965103b7f430b4affd87","SHA256Sum":"5d2576906306ea933575c6765957000e488707de8babec34e2f19168379ad6c5","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-238.1.165.0"},{"Checksum":[{"Filename":"kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u1.x86_64.rpm","SHA1Sum":"2866409631dea3c5eb0c4b66960ce22931d1d56e","SHA256Sum":"552138ced77cfcfb58713cbf7962df2b8714454bc583d037c5e2f5d6c083cd45","SHA512Sum":"d20b9f50b6b78fefe3c8ff0c73fe70117afc848253cc9fb7167fc43470fecc8e6b580cd124e168dbab141b9f6ab845ecbf7984d076e484349f9a4dd4b4598bba"}],"ComponentSizeInKB":1441,"CompsigList":["kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u1.x86_64.compsig"],"FileList":["./etc/depmod.d/bnxt_en.conf","./etc/depmod.d/bnxt_re.conf","./lib/modules/6.12.0-124.8.1.el10_1.x86_64","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/bnxt_en.ko","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband/hw","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re","./lib/modules/6.12.0-124.8.1.el10_1.x86_64/extra/bnxt_en/drivers/infiniband/hw/bnxt_re/bnxt_re.ko","./usr/share/smartupdate/kmod-bnxt_en/component.xml"],"Name":"kmod-bnxt_en-1.10.3-238.1.165.0.rhel10u1.x86_64.rpm","SHA1Sum":"2866409631dea3c5eb0c4b66960ce22931d1d56e","SHA256Sum":"552138ced77cfcfb58713cbf7962df2b8714454bc583d037c5e2f5d6c083cd45","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af"],"TypeOfChange":"1","Version":"1.10.3-238.1.165.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Drivers for Red Hat Enterprise Linux 10","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"},{"Name":"kmod-bnxt_en","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d8e855fe894f4c66b04c9f0054","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e4e120","a6b1a447-382a-5a4f-14e4-16d614e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e322","a6b1a447-382a-5a4f-14e4-16ee14e4e120","a6b1a447-382a-5a4f-14e4-16ee14e4e320","a6b1a447-382a-5a4f-14e4-16ef14e4e120","a6b1a447-382a-5a4f-14e4-16ef14e4e320","a6b1a447-382a-5a4f-14e4-16dc14e4e120","a6b1a447-382a-5a4f-14e4-16dc14e4e320","a6b1a447-382a-5a4f-14e4-16c514e4e120","a6b1a447-382a-5a4f-14e4-16c514e4e320","a6b1a447-382a-5a4f-14e4-16bd14e4e120","a6b1a447-382a-5a4f-14e4-16bd14e4e320","a6b1a447-382a-5a4f-14e4-16c114e4e120","a6b1a447-382a-5a4f-14e4-16c114e4e320","a6b1a447-382a-5a4f-14e4-16d714e4e122","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d714e41597","a6b1a447-382a-5a4f-14e4-16d714e41596","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d814e41593","a6b1a447-382a-5a4f-14e4-16d814e41592","a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16d614e41594","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ee14e41593","a6b1a447-382a-5a4f-14e4-16ee14e41592","a6b1a447-382a-5a4f-14e4-16ec14e4e122","a6b1a447-382a-5a4f-14e4-16ec14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ef14e41593","a6b1a447-382a-5a4f-14e4-16ef14e41592","a6b1a447-382a-5a4f-14e4-16ed14e4e122","a6b1a447-382a-5a4f-14e4-16ed14e4e322","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41594","a6b1a447-382a-5a4f-14e4-16ed14e41597","a6b1a447-382a-5a4f-14e4-16ed14e41596","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16de14e41594","a6b1a447-382a-5a4f-14e4-16ec14e41597","a6b1a447-382a-5a4f-14e4-16ec14e41596","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14e4-16dc14e4e122","a6b1a447-382a-5a4f-14e4-16dc14e4e322","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c514e4e122","a6b1a447-382a-5a4f-14e4-16c514e4e322","a6b1a447-382a-5a4f-14e4-16bd14e4e122","a6b1a447-382a-5a4f-14e4-16bd14e4e322","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c114e4e122","a6b1a447-382a-5a4f-14e4-16c114e4e322","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-176014e4e124","a6b1a447-382a-5a4f-14e4-176014e4e324","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-176014e4e116","a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-16c1159016d7"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","U40","U50","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","U26","U47","U47","U40","U50","U39","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","U54","U61","U60","U58","U58","U63","U62","U63","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","U64","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":0,"DeviceClass":"c734e171-8721-48c9-9ed6-d5bc7da5ef8d","Devices":{"Device":[{"DeviceName":"Innovation Engine (IE) Universal Image.","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"IEGen10_0.2.3.0.signed.bin","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-3c10-3c100a000303","Version":"0.2.3.0"}]},"Files":[{"Checksum":[{"Filename":"IEGen10_0.2.3.0.fwpkg","SHA1Sum":"cb3c2e94d23660857fe9f66cd398cfa93454481e","SHA256Sum":"3e9cd8f8c2f5ff32c0afb8cf840fba61ddc6b3fb7185bcf19930f90d32288517","SHA512Sum":"849b4d0539646d5ce13430bd99519c35013fd871221b8269d52f5cbabc87b9190c532a30b6c86736f602943e9f8c7ae4ba6aba27f4d0901c076a3138d4a5c30b"}],"ComponentSizeInKB":16409,"CompsigList":[],"FileList":["IEGen10_0.2.3.0.signed.bin","IEGen10_0.2.3.0.xml","IEGen10_0.2.3.0_B.signed.bin","payload.json"],"Name":"IEGen10_0.2.3.0.fwpkg","SHA1Sum":"cb3c2e94d23660857fe9f66cd398cfa93454481e","SHA256Sum":"3e9cd8f8c2f5ff32c0afb8cf840fba61ddc6b3fb7185bcf19930f90d32288517","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-3c10-3c100a000303"],"TypeOfChange":"1","Version":"0.2.3.0"}],"InstallationDependency":{},"Name":"ROM Flash Firmware Package - HPE Gen10 Innovation Engine Firmware for HPE Gen10 Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":60,"RebootRequired":"yes","SWKeys":[{"Name":"IE-Gen10","SWKeyExpectedPath":"firmware:ie"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_40c0e7a8438342b484e5d401d2","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0"]}],"SupportedPlatforms":true,"SupportedProducts":["I41","U34","U30","U32","U31","U31","U41","U33","U39","I43","I42","U34","U40","U37","U38","U38","U45","U39","H08","H08"],"Type":"Firmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.70 (08/19/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.70 (08/19/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073098.exe","SHA1Sum":"a896aedf36699bff046eb2252cf91935b24c7fce","SHA256Sum":"68153b4a2b874ecef811f30a1ddae73d8721312e0d48db3cde5d11b65f7dd890","SHA512Sum":"a64b3896cf4d78e5568205dfb00b53937006f8a20f51d11fd518542938b4351eaee8874d721cb79bf874d79a4f9bbbab0dd8c899a8db0b93a7410504b249a6c3"}],"ComponentSizeInKB":33443,"CompsigList":["cp073098_part1.compsig","cp073098_part2.compsig"],"FileList":["cp073098.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll","U46_2.70_08_19_2026.signed.flash"],"Name":"cp073098.exe","SHA1Sum":"a896aedf36699bff046eb2252cf91935b24c7fce","SHA256Sum":"68153b4a2b874ecef811f30a1ddae73d8721312e0d48db3cde5d11b65f7dd890","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_259d1d466ce24eecbdb3346e60","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U46","U46"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - Storage Fibre Channel","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp070510.zip","SHA1Sum":"dcc7053813bad9832b2dde959026e0c7dbc46609","SHA256Sum":"f257da5edf50f51e0879c2889f723bc445d9608c5bf4bb3f84db81cc8077f72f","SHA512Sum":"b4a8a37459175a73d6c8ba42bef61a9aa054c6ccdd87833419f17bf6c58efe874f714ae1d54cb6bf367adaf38e2cec99db5f655bb5ad87348c265ec657c210b3"}],"ComponentSizeInKB":860,"CompsigList":["cp070510.compsig"],"FileList":["/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip","/cp070510.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/index.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/vib20/qlnativefc/MVL_bootbank_qlnativefc_5.4.86.0-1OEM.803.0.0.24022510.vib","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip/vendor-index.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip/vmware.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip/vibs/qlnativefc-171623614172578347.xml","/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.zip/metadata.zip/bulletins/MRVL-QLogic-FC_5.4.86.0-1OEM.803.0.0.24022510.xml"],"Name":"cp070510.zip","SHA1Sum":"dcc7053813bad9832b2dde959026e0c7dbc46609","SHA256Sum":"f257da5edf50f51e0879c2889f723bc445d9608c5bf4bb3f84db81cc8077f72f","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.3"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb61a258e","20a6e8e4-bf33-4c71-a6bf-d9ecf3ddabfa"],"TypeOfChange":"1","Version":"2026.04.01","VibList":[{"Name":"qlnativefc","Version":"5.4.86.0-1OEM.803.0.0.24022510"}]}],"InstallationDependency":{},"Name":"HPE QLogic Fibre Channel driver component for VMware vSphere 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":380,"RebootRequired":"yes","SWKeys":[{"Name":"qlnativefc:5.4.86.0-1OEM.803.0.0.24022510","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"MRVL-QLogic-FC:5.4.86.0-1OEM.803.0.0.24022510","SWKeyExpectedPath":"driver.component:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9c7e37adf75248e4a7551f5be5","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System","U46"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072192.exe","SHA1Sum":"a0d80b4f1ad42cabe0e51fe837baf9f017cb7e8a","SHA256Sum":"b629f6675539765a0d32c430ff654ae1638851fc4ff1a50a92b0b9cfb7433dc1","SHA512Sum":"a721394eb12fe5c21c4363fd8d9e452118d21e2d3f463d2b55c68c4c051f46415707943f6a6611f450260c22f789bfb7a74fb2efdf8b15d5618402078ead137c"}],"ComponentSizeInKB":2435,"CompsigList":["cp072192.compsig"],"FileList":["cp072192.xml","cpqsetup.exe","cp_data.xml","install.xml","mlx5.cat","mlx5.inf","mlx5.sys","mlx5ui.dll","nicdrvr.dll"],"Name":"cp072192.exe","SHA1Sum":"a0d80b4f1ad42cabe0e51fe837baf9f017cb7e8a","SHA256Sum":"b629f6675539765a0d32c430ff654ae1638851fc4ff1a50a92b0b9cfb7433dc1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecb7ace047"],"TypeOfChange":"1","Version":"26.4.27095.0"}],"InstallationDependency":{},"Name":"Mellanox WinOF2 Driver for Microsoft Windows Server 2019","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"mlx5.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bc488ae5b86e4518a83dc06d30","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715b30116","a6b1a447-382a-5a4f-15b3-101715b30052","a6b1a447-382a-5a4f-15b3-101715b30117","a6b1a447-382a-5a4f-15b3-101d15b30042","a6b1a447-382a-5a4f-15b3-101515b30102","a6b1a447-382a-5a4f-15b3-101515b30047","a6b1a447-382a-5a4f-15b3-101d15b30040","a6b1a447-382a-5a4f-15b3-101815b30117","a6b1a447-382a-5a4f-15b3-101e15b30040","a6b1a447-382a-5a4f-15b3-101e15b30042","a6b1a447-382a-5a4f-15b3-101615b30102","a6b1a447-382a-5a4f-15b3-101615b30047","a6b1a447-382a-5a4f-15b3-101815b30116","a6b1a447-382a-5a4f-15b3-101815b30052","a6b1a447-382a-5a4f-15b3-101f15b30012","a6b1a447-382a-5a4f-15b3-101f15b30007","a6b1a447-382a-5a4f-15b3-101e15b30007","a6b1a447-382a-5a4f-15b3-101e15b30012"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","U47","A46","U47","U48","U47","U50","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","HPE Cray XD665","HPE Cray XD670","H11","U68","U68","U68","U71","U69","A58","U69","U70","U66","U71","U72","U68","A59","U72","A66","A66","U77","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE IB HDR/EN 200Gb 1p QSFP56 OCP3 Adptr","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.signed","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15b3-101b15900347","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"1c4f4c8f2ebac9fa591fd6fc3c5bff7e6f36a211","SHA256Sum":"80fa9600c579f2ea58014aae1b7ff676a2b694bae184c0fb260e34a1505ab17b","SHA512Sum":"51194821d71241e3768688d08825e676b29746f517bad50ea013881806eed475f6d34e7477dace656ae1a3c36833c098b365d4069138474cba29b7dc9d0ebc42"}],"ComponentSizeInKB":6138,"CompsigList":[],"FileList":["20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.signed","20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.xml","payload.json"],"Name":"20_43_8004-MCX653435A-HDA_HPE_Ax.pldm.fwpkg","SHA1Sum":"1c4f4c8f2ebac9fa591fd6fc3c5bff7e6f36a211","SHA256Sum":"80fa9600c579f2ea58014aae1b7ff676a2b694bae184c0fb260e34a1505ab17b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15b3-101b15900347"],"TypeOfChange":"1","Version":"20.43.8004"}],"InstallationDependency":{},"Name":"NVIDIA Firmware Package (FWPKG) for HPE InfiniBand HDR/Ethernet 200Gb 1-port QSFP56 PCIe4 x16 OCP3 MCX653435A-HDAI Adapter : HPE part numbers  P31323-B21 and  P31323-H21","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC_PLDM_MCX653435A-HDAI","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3f15f1eccb2e40be946ded02ab","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b15900347"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","6.0","7.0","8.0","9.0","11.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0","9.1","6.5","6.7"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U58","U58","A55","A55","A56","A56","U59","U58"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO002000KWVVC","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3230-3030-304b57565643","Version":"4ICRHPK3"},{"DeviceName":"VO004000KWVUR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3430-3030-304b57565552","Version":"4ICRHPK3"},{"DeviceName":"MO001600KWVUU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-304b57565555","Version":"4ICRHPK3"},{"DeviceName":"MO003200KWVUV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3330-3230-304b57565556","Version":"4ICRHPK3"},{"DeviceName":"MO006400KWVVA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"4ICRHPK3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3630-3430-304b57565641","Version":"4ICRHPK3"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-92d876cfea_4ICRHPK3-2.1_amd64.deb","SHA1Sum":"f8ef8d0437dab03c97900eba03bf3d3a4a0c1b82","SHA256Sum":"26daca030e03ef9d96ae473d66679cc3984011539d5e128a97c24f9b12ed07b5","SHA512Sum":"b4b54fed361e3055c4fdf0881a37cd951e07c1efb5fe89fad519acafbe700a8a123c1a837a14f06139d68abdb125c780811acba9f4db2f69cffa1e835d61d971"}],"ComponentSizeInKB":3703,"CompsigList":["firmware-hdd-92d876cfea_4ICRHPK3-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/4ICRHPK3.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/CP071756.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071756.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-92d876cfea-4ICRHPK3-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071756.scexe"],"Name":"firmware-hdd-92d876cfea_4ICRHPK3-2.1_amd64.deb","SHA1Sum":"f8ef8d0437dab03c97900eba03bf3d3a4a0c1b82","SHA256Sum":"26daca030e03ef9d96ae473d66679cc3984011539d5e128a97c24f9b12ed07b5","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"TypeOfChange":"1","Version":"4ICRHPK3"}],"InstallationDependency":{},"Name":"Online NVMe SSD Flash Component for Ubuntu Linux (x64) - VO002000KWVVC, VO004000KWVUR, MO001600KWVUU, MO003200KWVUV and MO006400KWVVA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO002000KWVVC","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"VO004000KWVUR","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO001600KWVUU","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO003200KWVUV","SWKeyExpectedPath":"firmware:sd:NVME"},{"Name":"MO006400KWVVA","SWKeyExpectedPath":"firmware:sd:NVME"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_034911c8b13c45c3bf533add81","SupportedDevices":["562340a5-304f-3230-3030-304b57565643","562340a5-304f-3430-3030-304b57565552","4d2340a5-304f-3130-3630-304b57565555","4d2340a5-304f-3330-3230-304b57565556","4d2340a5-304f-3630-3430-304b57565641"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825110-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C7","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4-rel-12_28_4706-825111-B21_Ax_Bx-UEFI-14.21.21-FlexBoot-3.6.103.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1013159000C8","Version":"12.28.4706"},{"DeviceName":"HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-872726-B21_Ax_Bx-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900256","Version":"16.35.8008"},{"DeviceName":"HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-879482-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900282","Version":"16.35.8008"}]},"Files":[{"Checksum":[{"Filename":"CP072401.zip","SHA1Sum":"52d194d88ad6d3aa4654ea54462da36212b8b099","SHA256Sum":"b0d216705523d89226afb174d11f1636cbad0ef757486c442d7d5ebc82edc753","SHA512Sum":"6471698ac90464a3eba380e25fb070fa438ca47038f7e6449619c1f8a3f332aad56491f26a9200b8f91bdfa71d89a1aba9e8e55cac5b50bf6a4ece4d1d6c9104"}],"ComponentSizeInKB":30978,"CompsigList":["CP072401.compsig"],"FileList":["/CP072401.xml","/CP072401_VMw.zip","/payload.json","/CP072401.vmexe64","/CP072401.vmfile","/CP072401_VMw.zip/index.xml","/CP072401_VMw.zip/vendor-index.xml","/CP072401_VMw.zip/metadata.zip","/CP072401_VMw.zip/vib20/CP072401/HPE_bootbank_CP072401_1.0.0-8.0.0.21495797.vib","/CP072401_VMw.zip/metadata.zip/vendor-index.xml","/CP072401_VMw.zip/metadata.zip/vmware.xml","/CP072401_VMw.zip/metadata.zip/vibs/CP072401--8200363872583394572.xml","/CP072401_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072401_1.0.0-8.0.0.21495797.xml"],"Name":"CP072401.zip","SHA1Sum":"52d194d88ad6d3aa4654ea54462da36212b8b099","SHA256Sum":"b0d216705523d89226afb174d11f1636cbad0ef757486c442d7d5ebc82edc753","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-1013159000C7","a6b1a447-382a-5a4f-15B3-1013159000C8","a6b1a447-382a-5a4f-15B3-101715900256","a6b1a447-382a-5a4f-15B3-101715900282"],"TypeOfChange":"1","Version":"1.0.7","VibList":[{"Name":"CP072401","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox VPI (Ethernet and Infiniband mode) ConnectX4 and ConnectX5 devices on VMware ESXi 8.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX4_CX5","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_14ac2a9d89e8486c95d69b8f35","SupportedDevices":["a6b1a447-382a-5a4f-15b3-1013159000c7","a6b1a447-382a-5a4f-15b3-1013159000c8","a6b1a447-382a-5a4f-15b3-101715900256","a6b1a447-382a-5a4f-15b3-101715900282"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","U31","U31","U41","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Controller","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"smartpqi-kmp-default-2.1.40-020.sles15sp6.x86_64.rpm","SHA1Sum":"33f5249bcfa2d4351f0a5319b7e02d184c3e121a","SHA256Sum":"77d2805bf59ef4af5dc530567717a8ac470d44fb9e4ff4494ae39ae9dc223d7f","SHA512Sum":"95eb8ce6e233e9f836399d492b27a2a397df21668bdeb8b4c6e36496429fa75c8d7de226eb433212f60048ec85234666925ac0c721bbe3710146dd480a09969c"}],"ComponentSizeInKB":108,"CompsigList":["smartpqi-kmp-default-2.1.40-020.sles15sp6.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"Name":"smartpqi-kmp-default-2.1.40-020.sles15sp6.x86_64.rpm","SHA1Sum":"33f5249bcfa2d4351f0a5319b7e02d184c3e121a","SHA256Sum":"77d2805bf59ef4af5dc530567717a8ac470d44fb9e4ff4494ae39ae9dc223d7f","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.40-020"},{"Checksum":[{"Filename":"smartpqi-kmp-default-2.1.40-020.sles15sp7.x86_64.rpm","SHA1Sum":"645cd39fdf10ba725f483c4530f6d431b9d58e82","SHA256Sum":"e9ccdab9cc988580ef883bd29bc7a4144c9e84fffc97618503a84d07f3b8e977","SHA512Sum":"76bad06530cf565e5f20b278e6be7decfa60a4e9d30cfb37478049a9cbc56bd4ea18b404a223889b079801a05eb8cc7d31abf3f2b5d1f28e2ab54e6b52624566"}],"ComponentSizeInKB":108,"CompsigList":["smartpqi-kmp-default-2.1.40-020.sles15sp7.x86_64.compsig"],"FileList":["./etc/dracut.conf.d/smartpqi.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/smartpqi.ko","./usr/share/smartupdate/smartpqi-kmp-default/component.xml"],"Name":"smartpqi-kmp-default-2.1.40-020.sles15sp7.x86_64.rpm","SHA1Sum":"645cd39fdf10ba725f483c4530f6d431b9d58e82","SHA256Sum":"e9ccdab9cc988580ef883bd29bc7a4144c9e84fffc97618503a84d07f3b8e977","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7"],"TypeOfChange":"1","Version":"2.1.40-020"}],"InstallationDependency":{},"Name":"HPE ProLiant Gen10, Gen10Plus and Gen11 Smart Array Controller (64-bit) Driver for SUSE LINUX Enterprise Server 15 (64-bit)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"smartpqi-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_d84b558b0a9948a388dcf8228c","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U37","U38","U38","U40","O43","I43","I42","U39","A42","U46","U46","A43","A42","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","HPE Apollo 2000 Gen10 Plus System","I44","U60","U61","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U57","U65","U65","U62","U71","U71","U68","U68","U72","U68","A66","A66"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp069724.exe","SHA1Sum":"41e290186c1c75152ea7bad3c8ab2389e33d098d","SHA256Sum":"6cb66d60b8b19fea7f1dd6b1395482b809e7914a9dd69797436fe2431d9d5a87","SHA512Sum":"f1e8ca3f1876baab9103173b20e0c54ba35828db555bfd382adba303ad09bc3cbb0132a8e5ecc761598cd524fbce6f13bb1ae55120b2a2039222a4175b192d46"}],"ComponentSizeInKB":572,"CompsigList":["cp069724.compsig"],"FileList":["cp069724.xml","cpqsetup.exe","generic.dll","install.xml","necheschif.cat","necheschif.inf","necheschif.sys"],"Name":"cp069724.exe","SHA1Sum":"41e290186c1c75152ea7bad3c8ab2389e33d098d","SHA256Sum":"6cb66d60b8b19fea7f1dd6b1395482b809e7914a9dd69797436fe2431d9d5a87","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec1417651e"],"TypeOfChange":"0","Version":"4.7.2.0"}],"InstallationDependency":{},"Name":"iLO 5 Channel Interface Driver for Microsoft Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":60,"RebootRequired":"no","SWKeys":[{"Name":"necheschif.sys","SWKeyExpectedPath":"%systemroot%\\system32\\DriverStore\\FileRepository\\necheschif.inf_amd64_e49bd7dc444fc00f"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_54d504f6c59f4fa29b42a809d8","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-33071590027f"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","A40","U30","U32","A43","A41","U31","U31","U41","U33","U44","A47","U40","U39","A46","U48","I43","I42","I44","U46","U46","U47","U47","U50","H08","H08","H10","H10","H10","U60","U61","U56","A42","A43","A43","A42","A48","U50","U39","U40","U64","H09"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Chipset","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072213.exe","SHA1Sum":"40704ec9ccfdd8d1918ab7430ed7e2a5149b1ba2","SHA256Sum":"7fe414ab4d068d4cd033e9ce2d884d882357a416f79fca28824ca870d52fea0b","SHA512Sum":"81c6a1153d0f8851d05e79a9efe364f49cd57d992365641e0d9a4687ff2b30fef50c2ec47346ead9e1c1fdc5bcb163a7524a88de034a955c158ac5d95374c4f1"}],"ComponentSizeInKB":609,"CompsigList":["cp072213.compsig"],"FileList":["cp072213.xml","cpqsetup.exe","installer.dll","pnp/","pnp/AMDCCP.cat","pnp/AMDCCP.inf","pnp/AMDPCIDev.cat","pnp/AMDPCIDev.inf","pnp/amdpsp.cat","pnp/amdpsp.inf","pnp/SMBUSamd.cat","pnp/SMBUSamd.inf"],"Name":"cp072213.exe","SHA1Sum":"40704ec9ccfdd8d1918ab7430ed7e2a5149b1ba2","SHA256Sum":"7fe414ab4d068d4cd033e9ce2d884d882357a416f79fca28824ca870d52fea0b","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec6a179209"],"TypeOfChange":"0","Version":"6.4.8.206"}],"InstallationDependency":{},"Name":"Identifiers for AMD EPYC Processors (Third Generation) for Microsoft Windows","PackageFormat":"","PerDeviceInstallTimeSeconds":600,"RebootRequired":"no","SWKeys":[{"Name":"installer.dll","SWKeyExpectedPath":"%ProgramFiles%\\Hewlett Packard Enterprise\\chipset"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_42d69affd54d4260ba08659b76","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","A40","A43","A41","A46","A47","A42","A43","A43","A42","A48"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"CP070950.zip","SHA1Sum":"015e4851fe15993466337dfa592c9927c08030eb","SHA256Sum":"b3354bfedb23ecc1c19d694eba56af14a361d27442bb446d533118b9c505cc41","SHA512Sum":"b8722d9c45124adcabe0c155f657e1c29ec672e5b8f244e682b3139132006be06635901ee57892e68d6fb94b2023327959c96c453df88162e6abdf401c62857c"}],"ComponentSizeInKB":19087,"CompsigList":["CP070950.compsig"],"FileList":["/CP070950_BUILD_3.data","/CP070950.vmexe64","/CP070950.vmfile","/CP070950_VMw.zip","/CP070950.xml","/payload.json","/CP070950_VMw.zip/index.xml","/CP070950_VMw.zip/vendor-index.xml","/CP070950_VMw.zip/metadata.zip","/CP070950_VMw.zip/vib20/CP070950/HPE_bootbank_CP070950_HPG5.3-8.0.0.20613240.vib","/CP070950_VMw.zip/metadata.zip/vendor-index.xml","/CP070950_VMw.zip/metadata.zip/vmware.xml","/CP070950_VMw.zip/metadata.zip/vibs/CP070950-448983189163845683.xml","/CP070950_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070950_HPG5.3-8.0.0.20613240.xml"],"Name":"CP070950.zip","SHA1Sum":"015e4851fe15993466337dfa592c9927c08030eb","SHA256Sum":"b3354bfedb23ecc1c19d694eba56af14a361d27442bb446d533118b9c505cc41","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG5","VibList":[{"Name":"CP070950","Version":"HPG5.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for VMware ESXi - MB016000GWXKK Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_22b0dd4e54874319b044d14eda","SupportedDevices":["4d2340a5-3042-3631-3030-304757584b4b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000GWXKK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG08acHPG5.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304757584b4b","Version":"HPG5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-e4f147cdd2_0HPG5-2.1_amd64.deb","SHA1Sum":"df9472ba7b4f9e44d9f0b98332531ce65bd8d562","SHA256Sum":"89e9da848ecf0ba5d0bdd707aa5c80315caa54502cd4f6bad0757fd15d87713e","SHA512Sum":"0f8096d96687486b7f6e0f3efb5eb4c71781f860268f4333d5d339f6ac5f4798ae573a41e568ed3cd96e1b248105810a26aa422e4f1345419b74a4c5e2811938"}],"ComponentSizeInKB":4343,"CompsigList":["firmware-hdd-e4f147cdd2_0HPG5-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/CP071786.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/TAMG08acHPG5.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071786.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-e4f147cdd2-HPG5-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071786.scexe"],"Name":"firmware-hdd-e4f147cdd2_0HPG5-2.1_amd64.deb","SHA1Sum":"df9472ba7b4f9e44d9f0b98332531ce65bd8d562","SHA256Sum":"89e9da848ecf0ba5d0bdd707aa5c80315caa54502cd4f6bad0757fd15d87713e","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304757584b4b"],"TypeOfChange":"1","Version":"HPG5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Ubuntu Linux (x64) - MB016000GWXKK Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000GWXKK","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_86fc9e1b06834d7fbc14713d07","SupportedDevices":["4d2340a5-3042-3631-3030-304757584b4b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":2,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hp-i40e-kmp-default-2.30.18_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"cd8d43a57d3136d0c1b0be530fab2d95c516362c","SHA256Sum":"494d7128a8b1a40ff393340c62ee69f06559e95889ff195f1750efe65ec07479","SHA512Sum":"b1d1736cc305d71f9dc8a20f76a9fb98cc4540e8eb8b5867ead4045abc5e17c980df045c78c0505099309ae65eecd5719a18c714d4329574e40bab3edf078574"}],"ComponentSizeInKB":5898,"CompsigList":["hp-i40e-kmp-default-2.30.18_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/hp-i40e","./lib/modules/6.4.0-150600.21-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"Name":"hp-i40e-kmp-default-2.30.18_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"cd8d43a57d3136d0c1b0be530fab2d95c516362c","SHA256Sum":"494d7128a8b1a40ff393340c62ee69f06559e95889ff195f1750efe65ec07479","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"TypeOfChange":"1","Version":"2.30.18-1"},{"Checksum":[{"Filename":"hp-i40e-kmp-default-2.30.18_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"03c4d28c800491bb4cbf81b0820f7ef688374b23","SHA256Sum":"1d58c1e7114e147d26ec88ae2dfe13f6f59a5c1849c5b407492c219cbea4dcb6","SHA512Sum":"4b1a6d9dae088d8016933bd4f23533f8d308b625addf0ae63ca94bb435f345a57746d92cc7825b4ec17041de59e85465eb65c48ca11e5c96b223af31e34164f9"}],"ComponentSizeInKB":439,"CompsigList":["hp-i40e-kmp-default-2.30.18_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./etc/depmod.d/hp-i40e.conf","./etc/dracut.conf.d/hp-i40e-oob.conf","./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/hp-i40e","./lib/modules/6.4.0-150700.51-default/updates/hp-i40e/i40e.ko","./usr/share/smartupdate/hp-i40e-kmp-default/component.xml"],"Name":"hp-i40e-kmp-default-2.30.18_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"03c4d28c800491bb4cbf81b0820f7ef688374b23","SHA256Sum":"1d58c1e7114e147d26ec88ae2dfe13f6f59a5c1849c5b407492c219cbea4dcb6","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd"],"TypeOfChange":"1","Version":"2.30.18-1"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 12 SP5 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"12.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy Intel Auxiliary Drivers for SUSE Linux Enterprise Server 15 SP3 must be installed prior to this component","OSVersion":{"Name":"sles","Value":"15.3"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec8d146608","SWKey":"hpe-auxiliary-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.3"}]}]}]},"Name":"HPE Intel i40e Drivers for SUSE Linux Enterprise Server 15","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"},{"Name":"hp-i40e-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ac1dfb9188fb4c3aa4b1016e6b","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-1572103c22fc","a6b1a447-382a-5a4f-8086-1572103c22fd","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d215900218","a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-1581159000f8"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","A40","U46","U30","U46","U32","A43","A43","A41","U31","U31","U36","U43","U41","U33","U44","J10","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","O43","U26","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","02020001","03020101","HPE Apollo 2000 Gen10 Plus System","A42","U56","H10","U61","U60","H10","H10","U64","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB016000JXLBA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3631-3030-304a584c4241","Version":"HPD3"},{"DeviceName":"MB018000JXLAU","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"PCHFA2B3.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3831-3030-304a584c4155","Version":"HPD3"}]},"Files":[{"Checksum":[{"Filename":"cp068749.exe","SHA1Sum":"fe5b3d34a007324d9151244e199202819467028f","SHA256Sum":"926d7a57e8af5a53ff1a3bcba9c2bcecf4bb1b57f787f77e715bb9d5de7a15cf","SHA512Sum":"6d9c4697968c5bd3406f68c6c83267cc6ee767ee8dd5839e992c7acf6eae564806bf77c689a017150e1839d56da6ff6cfbcc930011184d7cacce40e7d0f691d1"}],"ComponentSizeInKB":5212,"CompsigList":["cp068749.compsig"],"FileList":["cp068749.xml","cpqsetup.exe","mnv_cli.exe","payload.json","PCHFA2B3.rel","setup.dll"],"Name":"cp068749.exe","SHA1Sum":"fe5b3d34a007324d9151244e199202819467028f","SHA256Sum":"926d7a57e8af5a53ff1a3bcba9c2bcecf4bb1b57f787f77e715bb9d5de7a15cf","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"TypeOfChange":"1","Version":"HPD3"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB016000JXLBA and MB018000JXLAU Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB016000JXLBA","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB018000JXLAU","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c31b9cb8342244b7aab937df42","SupportedDevices":["4d2340a5-3042-3631-3030-304a584c4241","4d2340a5-3042-3831-3030-304a584c4155"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072274.exe","SHA1Sum":"b44759b2f0d8f9e361aec4ae771e42aec11cfd81","SHA256Sum":"a625b098d01091bd983054ea3fed5679900f29fef0385c5f2af3df4a14ac00de","SHA512Sum":"a36a064c80a9afe16fd36ca93b7f70b5d91f103f9a3768c9b48a600950b2973032459dd8ff373b9f5532fc5a7933260d90810683f49b6d9cbaa72718d9cf939e"}],"ComponentSizeInKB":1531,"CompsigList":["cp072274.compsig"],"FileList":["cp072274.xml","cpqsetup.exe","cp_data.xml","i40eb.cat","i40eb.inf","i40eb.sys","i40ebmsg.dll","install.xml","nicdrvr.dll"],"Name":"cp072274.exe","SHA1Sum":"b44759b2f0d8f9e361aec4ae771e42aec11cfd81","SHA256Sum":"a625b098d01091bd983054ea3fed5679900f29fef0385c5f2af3df4a14ac00de","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7dfbdb1d"],"TypeOfChange":"1","Version":"1.25.110.0"}],"InstallationDependency":{},"Name":"HPE Intel i40eb Driver for Windows Server 2025","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"i40eb.sys","SWKeyExpectedPath":"%systemroot%\\System32\\DriverStore\\FileRepository\\i40eb.inf_amd64_e2860b19128ec940"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c48e0bd98a724f7a8f8dac795f","SupportedDevices":["a6b1a447-382a-5a4f-8086-37ce15900215","a6b1a447-382a-5a4f-8086-37d115900216","a6b1a447-382a-5a4f-8086-37d115900247","a6b1a447-382a-5a4f-8086-37d315900219","a6b1a447-382a-5a4f-8086-37d115900217","a6b1a447-382a-5a4f-8086-37d215900218"],"SupportedOperatingSystems":[{"OS":"Azure","Version":["10.0.26100.26100"]},{"OS":"Windows","Version":["10.0.25399"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U43","U41","U33","U44","U40","U37","U38","U38","02020001","03020101","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"elx-lpfc-kmp-default-14.4.731.20_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"4d094000549756a6b985ee19f5c6e6fcfe19d08a","SHA256Sum":"4532d7a2775a00aa9b195511767983e877663bd4d98ed40997c9f511ba85c3f1","SHA512Sum":"549bd6ea8e72c3c5b9a4097e9204220c44ff84f20de01086579a29eed4defea55713573c358599436198ad37b58acd6d2aaf01ec51bbe76ea3711fe1e5462ce2"}],"ComponentSizeInKB":778,"CompsigList":["elx-lpfc-kmp-default-14.4.731.20_k6.4.0_150600.21-1.sles15sp6.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150600.21-default","./lib/modules/6.4.0-150600.21-default/updates","./lib/modules/6.4.0-150600.21-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"Name":"elx-lpfc-kmp-default-14.4.731.20_k6.4.0_150600.21-1.sles15sp6.x86_64.rpm","SHA1Sum":"4d094000549756a6b985ee19f5c6e6fcfe19d08a","SHA256Sum":"4532d7a2775a00aa9b195511767983e877663bd4d98ed40997c9f511ba85c3f1","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.731.20"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 15 Service Pack 6 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7ff034011bcb44e9bcc183e2e0","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"EG000300JWSJP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3330-304a57534a50","Version":"HPD6"},{"DeviceName":"EG000600JWJNH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3030-3630-304a574a4e48","Version":"HPD6"},{"DeviceName":"EG001200JWJNK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TA15SEN0HPD6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"452340a5-3047-3130-3230-304a574a4e4b","Version":"HPD6"}]},"Files":[{"Checksum":[{"Filename":"cp068763.exe","SHA1Sum":"8229f5d9249c1a4d76bff4a581aaea9da46adfbe","SHA256Sum":"d7d3fadc15fc0935e9011d00b8f2e856d78226775edb127e57509f78bf3b84d9","SHA512Sum":"aa88ec4d4ead30cfacc3e6c9faf958f6eae717881e7867ded078842d219d20737d1d4e90946b48f532da75dfd93d8f23fbb78693e6ec74f0c572bdacf58ace76"}],"ComponentSizeInKB":3179,"CompsigList":["cp068763.compsig"],"FileList":["cp068763.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TA15SEN0HPD6.rel"],"Name":"cp068763.exe","SHA1Sum":"8229f5d9249c1a4d76bff4a581aaea9da46adfbe","SHA256Sum":"d7d3fadc15fc0935e9011d00b8f2e856d78226775edb127e57509f78bf3b84d9","SoftwarePlatforms":[],"TargetGUIDs":["452340a5-3047-3030-3330-304a57534a50","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3130-3230-304a574a4e4b"],"TypeOfChange":"1","Version":"HPD6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - EG000300JWSJP, EG000600JWJNH and EG001200JWJNK Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"EG000300JWSJP","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG000600JWJNH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"EG001200JWJNK","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e186208a59f74883a23b4da1fb","SupportedDevices":["452340a5-3047-3130-3230-304a574a4e4b","452340a5-3047-3030-3630-304a574a4e48","452340a5-3047-3030-3330-304a57534a50"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB004000JWWQB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3430-3030-304a57575142","Version":"HPD8"},{"DeviceName":"MB002000JWWQA","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"SCIMARRNNSD8.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3230-3030-304a57575141","Version":"HPD8"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-adb3ab8147-HPD8-8.1.x86_64.rpm","SHA1Sum":"97904324297ff32a46c3311911ef5f51adf557bf","SHA256Sum":"91b70be08d4dac255c32e08898eeba6d33258cbabeda56b92ab2f624d139478d","SHA512Sum":"ab0bdb305af86a8ae6b3e928c57c685f34515767cd398541b976018074e4f1b9d6747ff456b0c61727d9575364b40c9c2ca71ec5a51eb5607298cd9017990aa7"}],"ComponentSizeInKB":5935,"CompsigList":["firmware-hdd-adb3ab8147-HPD8-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/CP068802.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/SCIMARRNNSD8.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-adb3ab8147-HPD8-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068802.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068802.scexe"],"Name":"firmware-hdd-adb3ab8147-HPD8-8.1.x86_64.rpm","SHA1Sum":"97904324297ff32a46c3311911ef5f51adf557bf","SHA256Sum":"91b70be08d4dac255c32e08898eeba6d33258cbabeda56b92ab2f624d139478d","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"TypeOfChange":"1","Version":"HPD8"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB004000JWWQB and MB002000JWWQA Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB004000JWWQB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB002000JWWQA","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e3c7f7487e78456cbb96dab819","SupportedDevices":["4d2340a5-3042-3430-3030-304a57575142","4d2340a5-3042-3230-3030-304a57575141"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b584e5848","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b584e5a56","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58504141","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58504142","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b584e5844","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b584e5a51","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b584e5a52","Version":"HPS7"},{"DeviceName":"Micron-7450U3-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"Micron_7450U3_M7450ALLHPS7.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b584e5a54","Version":"HPS7"}]},"Files":[{"Checksum":[{"Filename":"Micron_7450U3_M7450ALLHPS7.fwpkg","SHA1Sum":"4115c487768ac445063716b2c07d2dee18e7866b","SHA256Sum":"a872871f8f522469a1dcb30a0dc2c905bcbc1450ce2d7691a43a0d965ff58849","SHA512Sum":"f401ac836e8542559ffb704df0753a90d08bce5cd04ee6cfe42a191f83c8a2ca79d427cae6a2e3f0312d8aadc6f73d285fa2d3af6193e4c8e1c56aed9f82a6a6"}],"ComponentSizeInKB":2337,"CompsigList":[],"FileList":["Micron_7450U3_M7450ALLHPS7.HPb","Micron_7450U3_M7450ALLHPS7.xml","payload.json"],"Name":"Micron_7450U3_M7450ALLHPS7.fwpkg","SHA1Sum":"4115c487768ac445063716b2c07d2dee18e7866b","SHA256Sum":"a872871f8f522469a1dcb30a0dc2c905bcbc1450ce2d7691a43a0d965ff58849","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304b584e5848","4d2340a5-304f-3130-3630-304b584e5a56","4d2340a5-304f-3330-3230-304b58504141","4d2340a5-304f-3630-3430-304b58504142","562340a5-304f-3030-3936-304b584e5844","562340a5-304f-3130-3932-304b584e5a51","562340a5-304f-3330-3834-304b584e5a52","562340a5-304f-3730-3638-304b584e5a54"],"TypeOfChange":"1","Version":"HPS7"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - VO000960KXNXD, VO001920KXNZQ, VO003840KXNZR, VO007680KXNZT, MO000800KXNXH, MO001600KXNZV, MO003200KXPAA and MO006400KXPAB","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960KXNXD","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXNZQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXNZR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXNZT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO000800KXNXH","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXNZV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXPAA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXPAB","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_21dbae1890804e0a855212de38","SupportedDevices":["562340a5-304f-3130-3932-304b584e5a51","562340a5-304f-3330-3834-304b584e5a52","562340a5-304f-3730-3638-304b584e5a54","4d2340a5-304f-3030-3830-304b584e5848","4d2340a5-304f-3130-3630-304b584e5a56","4d2340a5-304f-3330-3230-304b58504141","4d2340a5-304f-3630-3430-304b58504142","562340a5-304f-3030-3936-304b584e5844"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0","7.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u2.x86_64.rpm","SHA1Sum":"a285526d4212cb4adc239882b80e674fd0fefcdb","SHA256Sum":"924feb0bd1a9093e736600cccc6450e4e7a1deedc4c999b951d4fa671f3c47cb","SHA512Sum":"e641bf3b3fc24a08beb479b907154de10219a8af3f1505f27940117d0b05a99b07af0dbd96c73393ed98e4616a11d9b604955125145cd20d703113cdc36ba117"}],"ComponentSizeInKB":5605,"CompsigList":["kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u2.x86_64.compsig"],"FileList":["./etc/depmod.d/qla2xxx.conf","./etc/dracut.conf.d/qla2xxx.conf","./etc/udev/rules.d/99-qla2xxx.rules","./lib/modules/6.12.0-211.7.3.el10_2.x86_64","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-qla2xxx","./lib/modules/6.12.0-211.7.3.el10_2.x86_64/extra/qlgc-qla2xxx/qla2xxx.ko","./lib/udev/qla2xxx_udev.sh","./usr/share/smartupdate/kmod-qlgc-qla2xxx/component.xml"],"Name":"kmod-qlgc-qla2xxx-10.02.16.00_k1-1.rhel10u2.x86_64.rpm","SHA1Sum":"a285526d4212cb4adc239882b80e674fd0fefcdb","SHA256Sum":"924feb0bd1a9093e736600cccc6450e4e7a1deedc4c999b951d4fa671f3c47cb","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec5b019cea"],"TypeOfChange":"1","Version":"10.02.16.00-k1"}],"InstallationDependency":{},"Name":"Red Hat Enterprise Linux 10 Update 2 Server Fibre Channel Driver Kit for HPE QLogic Host Bus Adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"kmod-qlgc-qla2xxx","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_883046cafe6a4dcf85f131dc57","SupportedDevices":["a6b1a447-382a-5a4f-1077-22811590036a","a6b1a447-382a-5a4f-1077-228115900369","a6b1a447-382a-5a4f-1077-2261159000fa","a6b1a447-382a-5a4f-1077-2261159000f9","a6b1a447-382a-5a4f-1077-226115900204","a6b1a447-382a-5a4f-1077-226115900203","a6b1a447-382a-5a4f-1077-2281159002d3","a6b1a447-382a-5a4f-1077-2281159002d4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":1,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U45","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U45_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000219","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u45-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"79baa20019b1039fcf49e62059166e7c58b7eb56","SHA256Sum":"a2c37199460462025c8b36dfbe3eaeb539fca82494026830ea33d3fb9bd59de8","SHA512Sum":"3bca3fe55b6dbf7a162feddcbab88d9c6978b231915e602253e531f3a26bd6e688d96cf3325c143dcb407171ae6a5732a8e86162046dc760806c7df0df35b26a"}],"ComponentSizeInKB":11253,"CompsigList":["firmware-system-u45-3.70_2026_08_19-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.70_2026_08_19-1.1/CP073189.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.70_2026_08_19-1.1/U45_3.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u45-3.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073189.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073189.scexe"],"Name":"firmware-system-u45-3.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"79baa20019b1039fcf49e62059166e7c58b7eb56","SHA256Sum":"a2c37199460462025c8b36dfbe3eaeb539fca82494026830ea33d3fb9bd59de8","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000219"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Apollo 6500 Gen10/HPE ProLiant XL270d Gen10 (U45) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U45","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a894826498fd4a279a41322270","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U45","HPE Apollo 6500 Gen10 System"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A41","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A41_3.80_05_28_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000217","Version":"v3.80 (05/28/2026)"}]},"Files":[{"Checksum":[{"Filename":"A41_3.80_05_28_2026.fwpkg","SHA1Sum":"ead527e8a7f8a8028e0369f10dd071d62bd69e20","SHA256Sum":"1cd9e9f0980e99fa86530736673043847bb1f777625c414c1f4cb7290869209b","SHA512Sum":"668b276c2c6e4329d297fe27acf07cb61ccbb6cd00a458dd3015dbef61b857388dbc40659a6b19bda356d4e76f6870b71af5ebc546b3709784b2f07db2e66075"}],"ComponentSizeInKB":32812,"CompsigList":[],"FileList":["A41_3.80_05_28_2026.signed.flash","A41_3.80_05_28_2026.xml","payload.json"],"Name":"A41_3.80_05_28_2026.fwpkg","SHA1Sum":"ead527e8a7f8a8028e0369f10dd071d62bd69e20","SHA256Sum":"1cd9e9f0980e99fa86530736673043847bb1f777625c414c1f4cb7290869209b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000217"],"TypeOfChange":"0","Version":"3.80_05-28-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE ProLiant DL325 Gen10 (A41) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A41","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b870fdf47b434cfbaacd2d20df","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.5","6.7","7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A41"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000225","Version":"v2.70 (08/19/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000000226","Version":"v2.70 (08/19/2026)"},{"DeviceName":"System BIOS - U46","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U46_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-00000000022c","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"firmware-system-u46-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"3d73ced73bdcd37f00b7456c3f93d60bee5f9540","SHA256Sum":"e4d719b05a3acf8b454afbe22f843bf200236270bce38e247d7f20d73ebefa95","SHA512Sum":"ced81bb55635ab95bd66169e2553f5789fa97e60b920a23939ef339cd15c490bf45cd8bde7ed5c294b81ad2856644a738866ec717ad88358a938bf294b11304c"}],"ComponentSizeInKB":33309,"CompsigList":["firmware-system-u46-2.70_2026_08_19-1.1.x86_64_part1.compsig","firmware-system-u46-2.70_2026_08_19-1.1.x86_64_part2.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.70_2026_08_19-1.1","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.70_2026_08_19-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.70_2026_08_19-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.70_2026_08_19-1.1/CP073105.xml","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.70_2026_08_19-1.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.70_2026_08_19-1.1/U46_2.70_08_19_2026.signed.flash","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.70_2026_08_19-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.70_2026_08_19-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-system-u46-2.70_2026_08_19-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073105.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073105.scexe"],"Name":"firmware-system-u46-2.70_2026_08_19-1.1.x86_64.rpm","SHA1Sum":"3d73ced73bdcd37f00b7456c3f93d60bee5f9540","SHA256Sum":"e4d719b05a3acf8b454afbe22f843bf200236270bce38e247d7f20d73ebefa95","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000225","00000000-0000-0000-0000-000000000226","00000000-0000-0000-0000-00000000022c"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE ProLiant DL360/DL380 Gen10 Plus (U46) Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U46","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_eacab1380e234893b48717d733","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["FTP","U46","U46"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000230","Version":"v4.04 (04/02/2026)"},{"DeviceName":"System BIOS - A42","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"A42_4.04_04_02_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000021d","Version":"v4.04 (04/02/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp071513.exe","SHA1Sum":"ec2afc724efd2209a64a74268cff47a836e1045e","SHA256Sum":"456dfba882953e8515c2f1c5658c270b4ff0b19d0852bae59851d3cc73d4150b","SHA512Sum":"7ee4f83d479755bde5a876470df0dca53231873cf1b3e68f9e011390faf17040f08c8345ba052fb36257446201c1651ef44f37fe01fc38670834cfb226846024"}],"ComponentSizeInKB":33442,"CompsigList":["cp071513_part1.compsig","cp071513_part2.compsig"],"FileList":["A42_4.04_04_02_2026.signed.flash","cp071513.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp071513.exe","SHA1Sum":"ec2afc724efd2209a64a74268cff47a836e1045e","SHA256Sum":"456dfba882953e8515c2f1c5658c270b4ff0b19d0852bae59851d3cc73d4150b","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000230","00000000-0000-0000-0000-00000000021d"],"TypeOfChange":"2","Version":"4.04_04-02-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE ProLiant DL365/DL385/DL385 v2 Gen10 Plus (A42) Servers","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"A42","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_852c409fc394413ebf1c1f404e","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A42","A42"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO000960JWZJF","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3030-3936-304a575a4a46","Version":"HPD5"},{"DeviceName":"VO001920JWZJH","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3130-3932-304a575a4a48","Version":"HPD5"},{"DeviceName":"VO003840JWZJK","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-304a575a4a4b","Version":"HPD5"},{"DeviceName":"VO007680JWZJL","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-304a575a4a4c","Version":"HPD5"},{"DeviceName":"VO015360JWZJN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"GPM1643ASAD5.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3531-3336-304a575a4a4e","Version":"HPD5"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-35fd24601f-HPD5-6.1.x86_64.rpm","SHA1Sum":"80425a54b8fdc1dbce3eb24679ae762887f48dfd","SHA256Sum":"6a87432ff1cb3991599af9c9179cd9186b5f0e32b087f50fbe3d4eb1325790ee","SHA512Sum":"0aa6755e763bd9f8e576a4a4db0f10bf3e629ea03d72b30262949d33a0affcccfa155c23ee0e9d5fd673c04cac6eae7c8c28d54276f7c3e705287d5e22aacc65"}],"ComponentSizeInKB":5191,"CompsigList":["firmware-hdd-35fd24601f-HPD5-6.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/CP068914.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/GPM1643ASAD5.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-35fd24601f-HPD5-6.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068914.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068914.scexe"],"Name":"firmware-hdd-35fd24601f-HPD5-6.1.x86_64.rpm","SHA1Sum":"80425a54b8fdc1dbce3eb24679ae762887f48dfd","SHA256Sum":"6a87432ff1cb3991599af9c9179cd9186b5f0e32b087f50fbe3d4eb1325790ee","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3030-3936-304a575a4a46","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3531-3336-304a575a4a4e"],"TypeOfChange":"1","Version":"HPD5"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - VO000960JWZJF, VO001920JWZJH, VO003840JWZJK, VO007680JWZJL and VO015360JWZJN Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO000960JWZJF","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO001920JWZJH","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO003840JWZJK","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680JWZJL","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO015360JWZJN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_431afbfd2b4549a49c85282054","SupportedDevices":["562340a5-304f-3531-3336-304a575a4a4e","562340a5-304f-3730-3638-304a575a4a4c","562340a5-304f-3330-3834-304a575a4a4b","562340a5-304f-3130-3932-304a575a4a48","562340a5-304f-3030-3936-304a575a4a46"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE_MR416i-p_Gen10p","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_MR416i-p_Gen10P_52.38.3-6909_A.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.38.3-6909"}]},"Files":[{"Checksum":[{"Filename":"HPE_MR416i-p_Gen10P_52.38.3-6909_A.fwpkg","SHA1Sum":"856eec8fa9f04ada4382dfff66d3e318cf72ba09","SHA256Sum":"c52ed9849a2f98e6449ebe29a970692b2d4190ed12b870402911e46064ca5e7e","SHA512Sum":"1d4e265e9935957da42708957dbce0e928f872b169341b6938dceb9b533dbac71bae0a4677f6d64d86c538eed010d82c68ca47d4271274828af0df36db14b0b2"}],"ComponentSizeInKB":7347,"CompsigList":[],"FileList":["HPE_MR416i-p_Gen10P_52.38.3-6909_A.HPb","HPE_MR416i-p_Gen10P_52.38.3-6909_A.xml","payload.json"],"Name":"HPE_MR416i-p_Gen10P_52.38.3-6909_A.fwpkg","SHA1Sum":"856eec8fa9f04ada4382dfff66d3e318cf72ba09","SHA256Sum":"c52ed9849a2f98e6449ebe29a970692b2d4190ed12b870402911e46064ca5e7e","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e215900293"],"TypeOfChange":"1","Version":"52.38.3-6909"}],"InstallationDependency":{},"MinimumActiveVersion":"52.26.3.5487","Name":"Firmware Package - HPE MR416i-p Gen10 Plus Tri Mode Controller","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"02931590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_dd329df938e642f3ad3e04450d","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0"]},{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["8.0","15.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","A43","A43","A42","U60","U46","U61","A59","U84","A72","U64","U48"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"ssacli-6.65-9.0_amd64.deb","SHA1Sum":"1ad12cb8f7fdfdd0495c7d34b6b6f2b5d4b57800","SHA256Sum":"20398bd1cb4c6b4852fcb9e1a5984b84c1550c5d5d50434a30069bc5c743470c","SHA512Sum":"f41cf281f5459d5413ff6388394d442aa345342d0da0f12f521f3d69a158eefc42d25eb066bb3a655351913908b30ec8187a15e6df3b29ddbb61c7ee37c393dc"}],"ComponentSizeInKB":10160,"CompsigList":["ssacli-6.65-9.0_amd64.compsig"],"FileList":["./opt/smartstorageadmin/ssacli/bin/mklocks.sh","./opt/smartstorageadmin/ssacli/bin/rmstr","./opt/smartstorageadmin/ssacli/bin/ssacli","./opt/smartstorageadmin/ssacli/bin/ssacli-6.65-9.0.x86_64.txt","./opt/smartstorageadmin/ssacli/bin/ssacli.license","./opt/smartstorageadmin/ssacli/bin/ssascripting","./usr/sbin/ssacli","./usr/sbin/ssascripting","./usr/share/doc/ssacli/changelog.Debian.gz","./usr/share/doc/ssacli/copyright","./usr/share/man/man8/ssacli.8.gz","./usr/share/smartupdate/ssacli/component.xml"],"Name":"ssacli-6.65-9.0_amd64.deb","SHA1Sum":"1ad12cb8f7fdfdd0495c7d34b6b6f2b5d4b57800","SHA256Sum":"20398bd1cb4c6b4852fcb9e1a5984b84c1550c5d5d50434a30069bc5c743470c","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ecff0816bd"],"TypeOfChange":"1","Version":"6.65.9.0"}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI for Ubuntu for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"ssacli","SWKeyExpectedPath":"software:deb"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fe2051e194754709b11cd98e2f","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","U31","U31","U36","U41","HPE ProLiant ML150 Gen10 Server","U33","U40","U39","U37","U38","U38","U40","U40","U39","U38","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","A42","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","I45","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U63","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","O42","U23","P99","P95","P92","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I37","I39","I40","U57","U65","U62","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp070629.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"cp070633.exe","SHA1Sum":"790e933d6314b81f3e418b876622f3dd97610025","SHA256Sum":"25d65db0cc6894805b27650ea7c47f57727088125afc3cfdf14c8a8ae04219ca","SHA512Sum":"4da3450f2cd918c2a31510fca40b98991eb43c465bca1c055d427aabfe39bdbc8d436752233b075d0cb5b95c73a51f08fc5d5a0781522aa567ef5b26cf4b9e8a"}],"ComponentSizeInKB":2863,"CompsigList":["cp070633.compsig"],"FileList":["cp070629.compsig","cp070629.zip","cp070633.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp070633.exe","SHA1Sum":"790e933d6314b81f3e418b876622f3dd97610025","SHA256Sum":"25d65db0cc6894805b27650ea7c47f57727088125afc3cfdf14c8a8ae04219ca","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant ML30 Gen10 Plus","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ded7c7d2a2864118895c7e0c7a","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U61","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AB","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AE","Version":"20.43.8004"},{"DeviceName":"HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-15B3-101B159002AF","Version":"20.43.8004"}]},"Files":[{"Checksum":[{"Filename":"cp071675.exe","SHA1Sum":"69ed7fb3785c5f69e278fe9a64612686cb0ed184","SHA256Sum":"554315366d12ebbdee951e321f669db0138a546574db5d8669bbf29e5a13c8a5","SHA512Sum":"278549f391643facd84ad54dc7f9512b263004c641b2547b1e6156045f29a6f6375437b714c05e9a5ee6f20e70b149d2c038ad927ce04aa390af9efd30152725"}],"ComponentSizeInKB":28675,"CompsigList":["cp071675.compsig"],"FileList":["cp071675.xml","cpqsetup.exe","fw-ConnectX6-rel-20_43_8004-P06154-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","fw-ConnectX6-rel-20_43_8004-P06250-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","fw-ConnectX6-rel-20_43_8004-P06251-B21_Ax-UEFI-14.37.50-FlexBoot-3.7.500.signed.bin","i2cbrdg.dll","installer.dll","libcmdif-1.dll","libgcc_s_seh-1.dll","libmlxfwops-1.dll","libmtcr-1.dll","libreg_access-1.dll","libstdc++-6.dll","libtools_sync-1.dll","libwinpthread-1.dll","libxml2.dll","mdevices.exe","mst64.sys","mstflint.exe","payload.json","perl526.dll","zlib1.dll"],"Name":"cp071675.exe","SHA1Sum":"69ed7fb3785c5f69e278fe9a64612686cb0ed184","SHA256Sum":"554315366d12ebbdee951e321f669db0138a546574db5d8669bbf29e5a13c8a5","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101B159002AB","a6b1a447-382a-5a4f-15B3-101B159002AE","a6b1a447-382a-5a4f-15B3-101B159002AF"],"TypeOfChange":"1","Version":"1.0.0.16"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec963fa3c9","SWKey":"kernel-mft-mlnx-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (Windows x64) for HPE NVIDIA VPI (Ethernet and Infiniband mode) ConnectX6 devices on Windows x86_64 platform","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_VPI_CX6_MFT","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3f05fb25d0d441bd85fe8a4c9a","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101b159002ab","a6b1a447-382a-5a4f-15b3-101b159002ae","a6b1a447-382a-5a4f-15b3-101b159002af"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","U32","HPE Apollo 6500 Gen10 Plus (Chassis)","U56","U61","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Power Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"9e48a28a-586c-4519-8405-a04f84e27f0f","Devices":{"Device":[{"DeviceName":"Gen10 Plus Power Management Controller Firmware","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"PICGen10_v1.1.4_hdr.signed.hex","InstallDurationSec":120,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"00000000-0000-0000-0000-000000504d05","Version":"1.1.4"}]},"Files":[{"Checksum":[{"Filename":"firmware-powerpic-gen10-1.1.4-8.1.x86_64.rpm","SHA1Sum":"ec8a3f519afbb0cb2d7c0aef6e8ffdce2f89d8d7","SHA256Sum":"ef707a05ac142870ea9e50ba4ec8acb4c6114eb8d1a1b92f84e418178d3df084","SHA512Sum":"f22d1483ede456e787c17535b663924a57673e028886f79d58a86e24836bc30b81c5ab1a565687fe5a2ae8ea4014bc916d7baba65e7ee9faf5674f617972acbe"}],"ComponentSizeInKB":215,"CompsigList":["firmware-powerpic-gen10-1.1.4-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/CP069832.xml","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/PICGen10_v1.1.4_hdr.signed.hex","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-powerpic-gen10-1.1.4-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP069832.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP069832.scexe"],"Name":"firmware-powerpic-gen10-1.1.4-8.1.x86_64.rpm","SHA1Sum":"ec8a3f519afbb0cb2d7c0aef6e8ffdce2f89d8d7","SHA256Sum":"ef707a05ac142870ea9e50ba4ec8acb4c6114eb8d1a1b92f84e418178d3df084","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000504d05"],"TypeOfChange":"1","Version":"1.1.4"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"},{"Condition":"AlreadyActive","Description":"For Gen10 server iLO version 1.40 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.40 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.40"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash for Linux - Advanced Power Capping Microcontroller Firmware for HPE Gen10, Gen10 Plus, and ML30 Gen11 Servers","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"PowerPIC-Gen10","SWKeyExpectedPath":"firmware:sd:powerpic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_305cf0a5e6cf4fedb2bbda7737","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","8.0","12.0","15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","A42","A42","A43","A43","A43","A41","A40","U34","U34","U46","U30","U46","U32","U31","U60","U43","U32","U41","U33","U61","U44","U50","U39","U50","U39","U56","U65"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB012000GWDFE","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WLHCWBA0HPG6.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3231-3030-304757444645","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-059b8654a6_0HPG6-1.1_amd64.deb","SHA1Sum":"e2e901ef5f656ebed8d6b5f195a379da5d3303e8","SHA256Sum":"e69a0f627a19c5e0889543e1beeea11ddd2f71d2430bcb4a8f55bfbe2664a2fb","SHA512Sum":"1363ef35873616d239817b43d6872cc4b962eb596c9e9c4bd02899a433c750c48b111f40e565b883c7e107db2c763d65c09df834b6ceec6aa027623284e5e226"}],"ComponentSizeInKB":4568,"CompsigList":["firmware-hdd-059b8654a6_0HPG6-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/CP067368.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/WLHCWBA0HPG6.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067368.scexe","./usr/lib/x86_64-linux-gnu/firmware-hdd-059b8654a6-HPG6-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067368.scexe"],"Name":"firmware-hdd-059b8654a6_0HPG6-1.1_amd64.deb","SHA1Sum":"e2e901ef5f656ebed8d6b5f195a379da5d3303e8","SHA256Sum":"e69a0f627a19c5e0889543e1beeea11ddd2f71d2430bcb4a8f55bfbe2664a2fb","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3231-3030-304757444645"],"TypeOfChange":"2","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB012000GWDFE Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB012000GWDFE","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f0b2c59f52c2492ab30bcaf711","SupportedDevices":["4d2340a5-3042-3231-3030-304757444645"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["26.04","24.04","22.04"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp064706.zip","SHA1Sum":"2ff1dfe747d5f41859f19fd09e3223db00c3fb8c","SHA256Sum":"921afb4c0acb174e8a1c264b62d0de48e38893eb65300023e0689b990162b16a","SHA512Sum":"a46dadc4f72ea61052210d56d31900cedb3c167720ce272c3badd9f7edd852fcb4f702d0fa9e6ea751ab3049b30e450f5bf1b5faaf8f162cd727f083227adeb0"}],"ComponentSizeInKB":1486,"CompsigList":["cp064706.compsig"],"FileList":["/cp064706.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3i/QLC_bootbank_qfle3i_2.1.14.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3/QLC_bootbank_qfle3_1.4.51.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qfle3f/QLC_bootbank_qfle3f_2.1.34.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/vib20/qcnic/QLC_bootbank_qcnic_2.0.67.0-1OEM.700.1.0.15843807.vib","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vendor-index.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vmware.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3i-1258983317020700904.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3-5679695447673383265.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qfle3f-2444618889340533499.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/vibs/qcnic--4650381188284540700.xml","/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807_24003260.zip/metadata.zip/bulletins/MRVL-E3-Ethernet-iSCSI-FCoE_3.0.251.0-1OEM.700.1.0.15843807.xml"],"Name":"cp064706.zip","SHA1Sum":"2ff1dfe747d5f41859f19fd09e3223db00c3fb8c","SHA256Sum":"921afb4c0acb174e8a1c264b62d0de48e38893eb65300023e0689b990162b16a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"7.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece189dca8","20a6e8e4-bf33-4c71-a6bf-d9ec4d7f9344","20a6e8e4-bf33-4c71-a6bf-d9ecbba24fc7","20a6e8e4-bf33-4c71-a6bf-d9ec7339bbbe","20a6e8e4-bf33-4c71-a6bf-d9eca261a1a0"],"TypeOfChange":"1","Version":"2025.03.00","VibList":[{"Name":"qfle3i","Version":"2.1.14.0-1OEM.700.1.0.15843807"},{"Name":"qfle3","Version":"1.4.51.0-1OEM.700.1.0.15843807"},{"Name":"qfle3f","Version":"2.1.34.0-1OEM.700.1.0.15843807"},{"Name":"qcnic","Version":"2.0.67.0-1OEM.700.1.0.15843807"}]}],"InstallationDependency":{},"Name":"HPE QLogic NX2 10/20 GbE Multifunction Driver for VMware vSphere 9.0","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"MRVL-E3-Ethernet-iSCSI-FCoE:3.0.251.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver.component:vmware:zip"},{"Name":"qfle3:1.4.51.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qcnic:2.0.67.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3i:2.1.14.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"},{"Name":"qfle3f:2.1.34.0-1OEM.700.1.0.15843807","SWKeyExpectedPath":"driver:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5b72663a36ec4ac2a8e3084a2a","SupportedDevices":["a6b1a447-382a-5a4f-14e4-168e103c339d","a6b1a447-382a-5a4f-14e4-168e103c18d3","a6b1a447-382a-5a4f-14e4-168e103c1930","a6b1a447-382a-5a4f-14e4-168e103c193a","a6b1a447-382a-5a4f-1077-16a1159000ec","a6b1a447-382a-5a4f-14e4-16af103c339d","a6b1a447-382a-5a4f-14e4-16af103c18d3","a6b1a447-382a-5a4f-14e4-16af103c193a","a6b1a447-382a-5a4f-14e4-16af103c1930","a6b1a447-382a-5a4f-14e4-16ae103c339d","a6b1a447-382a-5a4f-14e4-16ae103c18d3","a6b1a447-382a-5a4f-14e4-16ae103c193a","a6b1a447-382a-5a4f-14e4-16ae103c1930","a6b1a447-382a-5a4f-1077-16ad159000ec","a6b1a447-382a-5a4f-1077-16a4159000ec"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U26","U40","U39"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000JWKGN","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"WVL6CBA0HPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574b474e","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-a886842a99-HPD4-2.1.x86_64.rpm","SHA1Sum":"fc60776834986dbe2532c97808b6ce4695f9fc31","SHA256Sum":"2b65226e736dff43b633091fbcb7a749af0076599aefb0a14550b2ea9ee7c2f4","SHA512Sum":"662fc0e8e13a110144b28e9e7d504ac0e149e502059f580f840df0ebd79fd89c9f1969f9e82c1db7ab4cb07f71ef5e5dc3eab7831cd8132478b2d9a466ac1957"}],"ComponentSizeInKB":6283,"CompsigList":["firmware-hdd-a886842a99-HPD4-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/CP073201.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/WVL6CBA0HPD4.rel","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-a886842a99-HPD4-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP073201.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP073201.scexe"],"Name":"firmware-hdd-a886842a99-HPD4-2.1.x86_64.rpm","SHA1Sum":"fc60776834986dbe2532c97808b6ce4695f9fc31","SHA256Sum":"2b65226e736dff43b633091fbcb7a749af0076599aefb0a14550b2ea9ee7c2f4","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-304a574b474e"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB006000JWKGN Drive","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000JWKGN","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ddd22ae4d0c644f6a71929eb54","SupportedDevices":["4d2340a5-3042-3630-3030-304a574b474e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Driver - Storage Fibre Channel and Fibre Channel Over Ethernet","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"0f705d7c02b00387039f0de0a773ede33ff1cc05","SHA256Sum":"0f810a90bc2c9b16202fb6e50e1bd12d91ac2dc8ef58fc7747e7ac11dbeacb66","SHA512Sum":"e2f19bbd5ddb095a00eec62e8b3128b1dddb9eb3c97000f6716b7fefc3e3d5ffbf48658a4f72e592805e4a922424bd3ecb208045a0595ed45dd2a707b806c355"}],"ComponentSizeInKB":783,"CompsigList":["elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150700.51-1.sles15sp7.x86_64.compsig"],"FileList":["./lib/modules/6.4.0-150700.51-default","./lib/modules/6.4.0-150700.51-default/updates","./lib/modules/6.4.0-150700.51-default/updates/lpfc.ko","./usr/share/smartupdate/elx-lpfc-kmp-default/component.xml"],"Name":"elx-lpfc-kmp-default-14.4.731.6_k6.4.0_150700.51-1.sles15sp7.x86_64.rpm","SHA1Sum":"0f705d7c02b00387039f0de0a773ede33ff1cc05","SHA256Sum":"0f810a90bc2c9b16202fb6e50e1bd12d91ac2dc8ef58fc7747e7ac11dbeacb66","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec66940e1f"],"TypeOfChange":"1","Version":"14.4.731.6"}],"InstallationDependency":{},"Name":"SuSE Linux Enterprise Server 15 Service Pack 7 Fibre Channel Driver Kit for HPE Emulex Host Bus Adapter","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"elx-lpfc-kmp-default","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3be72de3c7ed4d1b94905d0eb7","SupportedDevices":["a6b1a447-382a-5a4f-10df-f40015900368","a6b1a447-382a-5a4f-10df-f40015900367","a6b1a447-382a-5a4f-10df-e30015900214","a6b1a447-382a-5a4f-10df-e30015900213","a6b1a447-382a-5a4f-10df-e30015900202","a6b1a447-382a-5a4f-10df-e30015900201","a6b1a447-382a-5a4f-10df-f400159002d5","a6b1a447-382a-5a4f-10df-f400159002d6"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A42","A40","U46","U30","A42","U46","U32","A43","A41","U31","U36","U41","A47","A48","U40","U50","U47","U37","A46","U47","U38","U38","U50","HPE Apollo 2000 Gen10 Plus System"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ OCP3 X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_OCP3_9p57_CFGID7p2_K97342_80010346.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1572808600A1","Version":"1.4002.0"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ X710-DA2 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//HPE_X710DA2_9p57_CFGID7p2_K97470_80010350.bin","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-157280860008","Version":"1.4002.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A1","Version":"1.4002.0"},{"DeviceName":"Intel I350-T4 Ethernet 1Gb 4-port BASE-T OCP3 Adapter for HPE","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1521808600A3","Version":"1.4002.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (2-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.4002.0"},{"DeviceName":"Intel(R) I350 Gigabit Network Connection (4-port)","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//BootIMG_ISA.FLB","InstallDurationSec":3600,"Order":2,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-152100000000","Version":"1.4002.0"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-is-intel-1.37.0-1.1.x86_64.rpm","SHA1Sum":"50c4d0fcab81286496e6c49d22bfd107d0e26552","SHA256Sum":"6c7b78065deb89fd99750c622da3d9b4020611f5f9793eda7ade74412cbb7b0a","SHA512Sum":"f54478ed605fac477cb221c02c6c1dabf6b977069b695042a993eca9ba2ea882f63aa120c693bcfbb5a4287889d1f999c660fe5a781e0d4586f651d53ea22b59"}],"ComponentSizeInKB":4679,"CompsigList":["firmware-nic-is-intel-1.37.0-1.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/CP072307.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/CP072307.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/deps/libs/libnvmupdatelinux.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/BootIMG_ISA.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_1G_Adapter_VPD_MAP_ISA.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000119C.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_I350_2p_Cu_NCSI_1.61_8000119C.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000119D.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_I350_4p_Cu_NCSI_1.61_8000119D.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_X710DA2_9p57_CFGID7p2_K97470_80010350.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_X710DA2_OCP3_9p57_CFGID7p2_K97342_80010346.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_X710_DA_OCP3_EEPROM_MAP.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_i350T4_K68277_8000123F.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_i350T4_K68277_8000123F.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001234.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/HPE_i350T4_OCP_K53978_80001234.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/hpesinglenvmconfig.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/hpnvmupdate.cfg","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/nic_fw/nvmupdate.sh","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-intel-1.37.0-1.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP072307.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP072307.scexe"],"Name":"firmware-nic-is-intel-1.37.0-1.1.x86_64.rpm","SHA1Sum":"50c4d0fcab81286496e6c49d22bfd107d0e26552","SHA256Sum":"6c7b78065deb89fd99750c622da3d9b4020611f5f9793eda7ade74412cbb7b0a","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1572808600A1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600A1","a6b1a447-382a-5a4f-8086-1521808600A3","a6b1a447-382a-5a4f-8086-152100000000"],"TypeOfChange":"1","Version":"1.37.0"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec7f45f646","SWKey":"hp-igb-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca93656a5","SWKey":"kmod-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igb Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf5d54211","SWKey":"kmod-hp-igb","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for SUSE Linux Enterprise Server 15 is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eccb9b3dbd","SWKey":"hp-i40e-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux 10 is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec805649d9","SWKey":"kmod-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40e Driver for Red Hat Enterprise Linux is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec243e7654","SWKey":"kmod-hp-i40e","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 9.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"9.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 8.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"8.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Intel-igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel igbn Driver for VMware vSphere 7.0 is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec62f4bb55","SWKey":"igbn","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec17ceb7c3","SWKey":"i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Intel i40en Driver for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Intel-i40en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Intel Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":3600,"RebootRequired":"yes","SWKeys":[{"Name":"IS_INTEL","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ebeb8c26a8da4ac3853c4e4523","SupportedDevices":["a6b1a447-382a-5a4f-8086-1572808600a1","a6b1a447-382a-5a4f-8086-157280860008","a6b1a447-382a-5a4f-8086-1521808600a1","a6b1a447-382a-5a4f-8086-1521808600a3","a6b1a447-382a-5a4f-8086-152100000000","a6b1a447-382a-5a4f-8086-152100000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["02020001","03020101","A59","A42","U46","U46","A43","A47","A48","A46","U47","U48","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","A42","U56","U61","U60","U64","U54","U54","U54","U58","U58","U63","U62","U63","U57","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","A55","A55","A56","A56","U59","03030201","U58","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","U72","U70","A66","A66","A42","U46","U77","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"VO003840XZCLT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3330-3834-30585a434c54","Version":"HPD4"},{"DeviceName":"VO007680XZCMB","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"562340a5-304f-3730-3638-30585a434d42","Version":"HPD4"},{"DeviceName":"MO000800XZCLQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3030-3830-30585a434c51","Version":"HPD4"},{"DeviceName":"MO001600XZCLV","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"KAPM6ALFHPD4.rel","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-304f-3130-3630-30585a434c56","Version":"HPD4"}]},"Files":[{"Checksum":[{"Filename":"cp068651.exe","SHA1Sum":"00f8df909caf978c384b83369e378268dc55b972","SHA256Sum":"5176dbc041c20cd64475c4a2fbfcd8985b798dc59c6193a67b36d9580c81f5eb","SHA512Sum":"75b584c255f602527a24c376b780652153c688d8ae99c477e50e9b0acf4b65388e6539eb34bcef6338eff477772d3cd877035ced71ccc4a09bf36a2d6f1b7dd5"}],"ComponentSizeInKB":4010,"CompsigList":["cp068651.compsig"],"FileList":["cp068651.xml","cpqsetup.exe","KAPM6ALFHPD4.rel","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp068651.exe","SHA1Sum":"00f8df909caf978c384b83369e378268dc55b972","SHA256Sum":"5176dbc041c20cd64475c4a2fbfcd8985b798dc59c6193a67b36d9580c81f5eb","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-304f-3330-3834-30585a434c54","562340a5-304f-3730-3638-30585a434d42","4d2340a5-304f-3030-3830-30585a434c51","4d2340a5-304f-3130-3630-30585a434c56"],"TypeOfChange":"1","Version":"HPD4"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - VO003840XZCLT, VO007680XZCMB, MO000800XZCLQ and MO001600XZCLV Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VO003840XZCLT","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"VO007680XZCMB","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO000800XZCLQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MO001600XZCLV","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_34f98f1102e24c1dbf193b4820","SupportedDevices":["562340a5-304f-3330-3834-30585a434c54","4d2340a5-304f-3130-3630-30585a434c56","4d2340a5-304f-3030-3830-30585a434c51","562340a5-304f-3730-3638-30585a434d42"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398","10.0","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3030-3830-304b58505256","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3130-3630-304b58505452","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3330-3230-304b58505454","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"4d2340a5-304f-3630-3430-304b58505455","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3030-3936-304b58505255","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3130-3932-304b5850544e","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3330-3834-304b58505450","Version":"HPK2"},{"DeviceName":"SKHynix-PE81X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE81X0_KPE81X0AHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-304f-3730-3638-304b58505451","Version":"HPK2"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PE81X0_KPE81X0AHPK2.fwpkg","SHA1Sum":"a7ca59c7dc75e45555e03abb49e4ffc1766cc53b","SHA256Sum":"07a1568323099b051a4b1576b610a947cd84da072a1d1e04d81883dc7e5a8cfa","SHA512Sum":"4034ddbc8681e09a856c8a3c6621485402230c8f8fd86bd48f92fdab70b6a8d2a95eb6166de6bd5e2647c2644fd4bfe610b1f57abb85b2711f82ab26adc761de"}],"ComponentSizeInKB":6114,"CompsigList":[],"FileList":["payload.json","SKHynix_PE81X0_KPE81X0AHPK2.HPb","SKHynix_PE81X0_KPE81X0AHPK2.xml"],"Name":"SKHynix_PE81X0_KPE81X0AHPK2.fwpkg","SHA1Sum":"a7ca59c7dc75e45555e03abb49e4ffc1766cc53b","SHA256Sum":"07a1568323099b051a4b1576b610a947cd84da072a1d1e04d81883dc7e5a8cfa","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-304f-3030-3830-304b58505256","4d2340a5-304f-3130-3630-304b58505452","4d2340a5-304f-3330-3230-304b58505454","4d2340a5-304f-3630-3430-304b58505455","562340a5-304f-3030-3936-304b58505255","562340a5-304f-3130-3932-304b5850544e","562340a5-304f-3330-3834-304b58505450","562340a5-304f-3730-3638-304b58505451"],"TypeOfChange":"1","Version":"HPK2"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives - MO000800KXPRV, MO001600KXPTR, MO003200KXPTT, MO006400KXPTU, VO000960KXPRU, VO001920KXPTN, VO003840KXPTP and VO007680KXPTQ","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MO000800KXPRV","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO001600KXPTR","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO003200KXPTT","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"MO006400KXPTU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO000960KXPRU","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO001920KXPTN","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO003840KXPTP","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VO007680KXPTQ","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_b3ac2dd86a7d4e9aa334041028","SupportedDevices":["4d2340a5-304f-3030-3830-304b58505256","4d2340a5-304f-3130-3630-304b58505452","4d2340a5-304f-3330-3230-304b58505454","4d2340a5-304f-3630-3430-304b58505455","562340a5-304f-3030-3936-304b58505255","562340a5-304f-3130-3932-304b5850544e","562340a5-304f-3330-3834-304b58505450","562340a5-304f-3730-3638-304b58505451"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.17600.18999","10.0"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Software - Lights-Out Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"hponcfg-6.1.0-0.x86_64.rpm","SHA1Sum":"98ecadf350d759cd5399e08b28c0e86d1af94aef","SHA256Sum":"dfd43f64998af8b459c3db06e9712a93814756f7bc6fae1268d6de594f8ecc36","SHA512Sum":"16d4f74e61ba339db4494dfaf2047f503572ffcb718405204a869228b65dab706f4fdecf414e1390dd49b00098441c34d91232f306200ca4a2a70c07571e003a"}],"ComponentSizeInKB":62,"CompsigList":["hponcfg-6.1.0-0.x86_64.compsig"],"FileList":["./sbin/hponcfg","./usr/lib64/libhponcfg64.so","./usr/share/doc/hponcfg","./usr/share/doc/hponcfg/readme.txt","./usr/share/smartupdate/hponcfg/component.xml"],"Name":"hponcfg-6.1.0-0.x86_64.rpm","SHA1Sum":"98ecadf350d759cd5399e08b28c0e86d1af94aef","SHA256Sum":"dfd43f64998af8b459c3db06e9712a93814756f7bc6fae1268d6de594f8ecc36","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9eccecbdbe8"],"TypeOfChange":"0","Version":"6.1.0.0"}],"InstallationDependency":{},"Name":"HPE Lights-Out Online Configuration Utility for Linux (AMD64/EM64T)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"hponcfg","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6abdf231475c435c92bb558b96","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306103c3381","a6b1a447-382a-5a4f-103c-3307103c3381","a6b1a447-382a-5a4f-103c-3308103c3381","a6b1a447-382a-5a4f-103c-3300103c3381","a6b1a447-382a-5a4f-103c-3301103c3381","a6b1a447-382a-5a4f-103c-3302103c3381","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103C-330600000000","a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103c-3306159000e4"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["10.0","11.0","6.0","7.0","12.0","15.0","8.0","9.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I38","I32","A26","I41","I36","I31","I30","U34","U17","P79","U34","P85","P77","P89","A42","A40","A28","U46","U30","P89","P70","P73","A42","U46","U32","P89","P71","P73","A43","A43","A43","A41","P80","J05","U31","U20","U31","U20","J03","U36","P86","U15","U15","U43","U22","U41","P92","P72","J02","P78","J04","P95","U33","P99","U44","U23","O42","J10","P88","P74","P75","P75","P75","P75","P83","U51","U18","U18","U18","A47","A48","U40","U21","U50","U39","U47","U45","U25","U24","U24","U13","U37","U13","A46","U47","P94","A48","U38","U14","U38","U14","U48","J06","U26","I36","I31","A45","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U47","U47","Carbondale14","Carbondale14","Carbondale14","U50","U19","U46","I40","I43","I39","I40","I45","I44","I42","I37","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","U57","A55","A55","A56","A56","U59","U64","U58","R11","U65","U65","U65","H11","U69","A58","R13","U69","U70","U66","A59","HPE ProLiant ML150 Gen10 Server","O43","U38","U38","U38","HPE Apollo 6500 Gen10 System","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U40","U39","H08","H08","H09","HPE Apollo 2000 Gen10 Plus System","U70"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":2,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - H10","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"H10_2.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-00000000023a","Version":"v2.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"cp073116.exe","SHA1Sum":"50e9aaed9c9abc18221d42320e98d8746bcd305a","SHA256Sum":"97ccf3bcd4a327406a9a5750bccfb5fd127ecea9b00fa2aaabf0cc11e0332a7f","SHA512Sum":"5cfcf59a8616833d7fd2b75bb527285924212dd0c89a11b5593a578611c7ec9cec4c972e135fdfe88b95d737a750eb585a81e2fa94403630c8c09b56d05029ed"}],"ComponentSizeInKB":33436,"CompsigList":["cp073116_part1.compsig","cp073116_part2.compsig"],"FileList":["cp073116.xml","cpqsetup.exe","H10_2.70_08_19_2026.signed.flash","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp073116.exe","SHA1Sum":"50e9aaed9c9abc18221d42320e98d8746bcd305a","SHA256Sum":"97ccf3bcd4a327406a9a5750bccfb5fd127ecea9b00fa2aaabf0cc11e0332a7f","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-00000000023a"],"TypeOfChange":"0","Version":"2.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Edgeline e920, e920d and e920t CTO Blade Server (H10)","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"H10","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_e3c621005d04452684d6a8c995","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["HPE Edgeline EL8000t Converged Edge System","H10","FTP","H10","H10"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - PCIe NVMe Storage Disk","ComponentLocation":"","CompsigCount":0,"DeviceClass":"f6de0320-2e0f-489a-b238-6dd8ae7c3811","Devices":{"Device":[{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE90X0_KPE9010IHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3438-304b59585051","Version":"HPK2"},{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE90X0_KPE9010IHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3030-3936-304b59585141","Version":"HPK2"},{"DeviceName":"SKHynix-PE90X0-NVMe","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"SKHynix_PE90X0_KPE9010IHPK2.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"562340a5-3052-3130-3932-304b59585142","Version":"HPK2"}]},"Files":[{"Checksum":[{"Filename":"SKHynix_PE90X0_KPE9010IHPK2.fwpkg","SHA1Sum":"f461ec6e0f8a64f10da8fd26cddc1fcd1c7913f5","SHA256Sum":"82cadf1c03809a3b5ec339fa89d12b19ac22fa4b968d0c5f64d79834310ca591","SHA512Sum":"4ed2a2c7770dc11b81b09d1024163a9c7b6da03440d36f398f9fb826f27e80fe8f3638ecca8ca331e831614800e5d6250855ad5bb98f18efd48a1e235c30b821"}],"ComponentSizeInKB":5620,"CompsigList":[],"FileList":["payload.json","SKHynix_PE90X0_KPE9010IHPK2.HPb","SKHynix_PE90X0_KPE9010IHPK2.xml"],"Name":"SKHynix_PE90X0_KPE9010IHPK2.fwpkg","SHA1Sum":"f461ec6e0f8a64f10da8fd26cddc1fcd1c7913f5","SHA256Sum":"82cadf1c03809a3b5ec339fa89d12b19ac22fa4b968d0c5f64d79834310ca591","SoftwarePlatforms":[],"TargetGUIDs":["562340a5-3052-3030-3438-304b59585051","562340a5-3052-3030-3936-304b59585141","562340a5-3052-3130-3932-304b59585142"],"TypeOfChange":"1","Version":"HPK2"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032c","SWKey":"032C1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus servers firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032b","SWKey":"032B1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-a Gen10 Plus Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e21590032a","SWKey":"032A1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen10 Plus Tri Mode Controller with Gen10 and Gen10 Plus server firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900293","SWKey":"02931590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900383","SWKey":"03831590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900382","SWKey":"03821590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0651","SWKey":"0651103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0650","SWKey":"0650103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0652","SWKey":"0652103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0654","SWKey":"0654103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0700","SWKey":"0700103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0600","SWKey":"0600103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0603","SWKey":"0603103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0602","SWKey":"0602103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c0601","SWKey":"0601103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1101","SWKey":"1101103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, E208i-p, E208e-p, E208i-c, E208i-a, P408e-m, P204i-c, P416ie-m and P816i-a SR Gen10 and Gen11 controllers firmware version 6.22 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f103c1100","SWKey":"1100103C","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.22"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900329","SWKey":"03291590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR408i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e2159003c8","SWKey":"03C81590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-o Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900328","SWKey":"03281590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR216i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900326","SWKey":"03261590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002db","SWKey":"02DB1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f1590032e","SWKey":"032E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900381","SWKey":"03811590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f15900294","SWKey":"02941590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE SR932i-p Gen10 Plus /SR416i-a Gen10 Plus/SR932i-p Gen11/SR416ie-m Gen11 Controllers firmware version 03.01.23.072 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-9005-028f159002dc","SWKey":"02DC1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"03.01.23.072"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900379","SWKey":"03791590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900380","SWKey":"03801590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-2241159002f6","SWKey":"02F61590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030e","SWKey":"030E1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-22411590030f","SWKey":"030F1590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r firmware version 1.2.14.1009 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1b4b-224115900310","SWKey":"03101590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.2.14.1009"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE MR416i-p Gen11 Tri Mode Controller firmware version 52.24.3-4948 or greater is required and should be already active for fwpkg driver update. Update the firmware and reboot before attempting firmware update.","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-1000-10e215900325","SWKey":"03251590","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"52.24.3-4948"}]}]}]},"Name":"Universal Firmware Package for Drives -  VR000480KYXPQ, VR000960KYXQA and VR001920KYXQB","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"VR000480KYXPQ","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR000960KYXQA","SWKeyExpectedPath":"firmware:sd:nvme"},{"Name":"VR001920KYXQB","SWKeyExpectedPath":"firmware:sd:nvme"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ef508d000e044335b7e1498570","SupportedDevices":["562340a5-3052-3030-3438-304b59585051","562340a5-3052-3030-3936-304b59585141","562340a5-3052-3130-3932-304b59585142"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0","10.0.17600.18999"]},{"OS":"Linux","Version":["8.0","15.0","12.0","9.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"ComboFirmware","UpdatableBy":["Bmc","Uefi"]},{"BundleIndex":0,"Category":"Driver - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072683.exe","SHA1Sum":"0b0c3e6600cb2fb6bf229788e007f39af660ed4f","SHA256Sum":"64ee5fa2b77ef91c44b4489f6e5e8a9a61ed94bfda4b54c5dbf29665246b48fe","SHA512Sum":"c75a7c8cc79a878d418bf0802d3383aa568f625acf2e980d7a4f168d54d452bf23dfe8cfa6152a786d70aee132087afd1e7bae88b87c1d983e7f3847e7aac584"}],"ComponentSizeInKB":1102,"CompsigList":["cp072683.compsig"],"FileList":["bnxtnd.cat","bnxtnd.inf","bnxtnd.man","bnxtnd.sys","cp072683.xml","cpqsetup.exe","cp_data.xml","install.xml","nicdrvr.dll"],"Name":"cp072683.exe","SHA1Sum":"0b0c3e6600cb2fb6bf229788e007f39af660ed4f","SHA256Sum":"64ee5fa2b77ef91c44b4489f6e5e8a9a61ed94bfda4b54c5dbf29665246b48fe","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec919626a4"],"TypeOfChange":"1","Version":"238.1.110.0"}],"InstallationDependency":{},"Name":"HPE Broadcom NetXtreme-E Driver for Windows Server 2022","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"bnxtnd.sys","SWKeyExpectedPath":"%systemroot%\\system32\\drivers"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6fbba13b900649bc96d7827c49","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16dc159002c3","a6b1a447-382a-5a4f-14e4-16dc159002c5","a6b1a447-382a-5a4f-14e4-16c5159002c3","a6b1a447-382a-5a4f-14e4-16c5159002c5","a6b1a447-382a-5a4f-14e4-16c1159002c3","a6b1a447-382a-5a4f-14e4-16c1159002c5","a6b1a447-382a-5a4f-14e4-16bd159002c3","a6b1a447-382a-5a4f-14e4-16bd159002c5","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16dc159016d8","a6b1a447-382a-5a4f-14e4-16dc159016d7","a6b1a447-382a-5a4f-14E4-16C500000000","a6b1a447-382a-5a4f-14e4-16c51590020c","a6b1a447-382a-5a4f-14e4-16c515900211","a6b1a447-382a-5a4f-14e4-16c51590020e","a6b1a447-382a-5a4f-14e4-16c1159016d8","a6b1a447-382a-5a4f-14e4-16c1159016d7","a6b1a447-382a-5a4f-14E4-16BD00000000","a6b1a447-382a-5a4f-14e4-16bd1590020c","a6b1a447-382a-5a4f-14e4-16bd15900211","a6b1a447-382a-5a4f-14e4-16bd1590020e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U37","U38","U38","O43","U26","U39","02020001","03020101","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD225v","HPE Cray XD665","HPE Cray XD670","A59","03020102"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-1537FFFF0000","Version":"1.2877"},{"DeviceName":"HPE Ethernet i210-T1 GbE NIC","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":"./BootIMG.FLB","InstallDurationSec":60,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-153700000000","Version":"1.2877"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-i210-nic-1.2877-3.1.x86_64.rpm","SHA1Sum":"611578e2658d6be712cc0eb70af0937c664cae01","SHA256Sum":"0279b6721832ab168edfc917ca4ada7bf99140cc84930dc3a682ca2f2a0c817b","SHA512Sum":"291b8b55a6152ab6084561e611a6af2acceaa51b0dc0b3bcf78a6281d820ca8bc034b8577c0497499bf7b3d458aaf03642ec6e492705ed6646cadfe00b778ddc"}],"ComponentSizeInKB":9127,"CompsigList":["firmware-nic-i210-nic-1.2877-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/BootIMG.FLB","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/CP071035.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/bootutil64e","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/ilorest_chif.so","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-i210-nic-1.2877-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071035.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071035.scexe"],"Name":"firmware-nic-i210-nic-1.2877-3.1.x86_64.rpm","SHA1Sum":"611578e2658d6be712cc0eb70af0937c664cae01","SHA256Sum":"0279b6721832ab168edfc917ca4ada7bf99140cc84930dc3a682ca2f2a0c817b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-1537FFFF0000","a6b1a447-382a-5a4f-8086-153700000000"],"TypeOfChange":"1","Version":"1.2877"}],"InstallationDependency":{},"Name":"HPE Edgeline i210 NIC Firmware Component for Linux","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"yes","SWKeys":[{"Name":"i210_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9ca69affcbbb4a85a87a5fd02e","SupportedDevices":["a6b1a447-382a-5a4f-8086-153700000000","a6b1a447-382a-5a4f-8086-1537FFFF0000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","7.0","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["H08","H08","H10","H10","H10","HPE Cray XD220v","HPE Cray XD295v","HPE Cray XD665"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"757378B9-0016-4DEB-97DB-02BF1CD0B86A","Devices":{"Device":[{"DeviceName":"HPE Ethernet 100Gb 1-port 842QSFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX5-rel-16_35_8008-874253-B21_Ax-UEFI-14.29.15-FlexBoot-3.6.902.signed.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-101715900246","Version":"16.35.8008"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640 FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817749-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D3","Version":"14.32.1912"},{"DeviceName":"HPE Ethernet 25Gb 2-port 640SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//fw-ConnectX4Lx-rel-14_32_1912-817753-B21_Ax-UEFI-14.25.17-FlexBoot-3.6.502.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-15B3-1015159000D4","Version":"14.32.1912"}]},"Files":[{"Checksum":[{"Filename":"CP072361.zip","SHA1Sum":"946ca6afb19a6ee94101163ef4a59e58fa3a690e","SHA256Sum":"516123b27c25890f9da4095ef7c57b4eee05542c2c47d98ece8227b58e099ad2","SHA512Sum":"c70feab8ab4b49981eb9d13b6260081050e867edddf01a5a17e919482d1d8d0f989dc861673661023fb89b2f8288507e1d7f2c94c33978c2f1bec07eadc39170"}],"ComponentSizeInKB":26571,"CompsigList":["CP072361.compsig"],"FileList":["/CP072361.xml","/CP072361_VMw.zip","/payload.json","/CP072361.vmexe64","/CP072361.vmfile","/CP072361_VMw.zip/index.xml","/CP072361_VMw.zip/vendor-index.xml","/CP072361_VMw.zip/metadata.zip","/CP072361_VMw.zip/vib20/CP072361/HPE_bootbank_CP072361_1.0.0-8.0.0.21495797.vib","/CP072361_VMw.zip/metadata.zip/vendor-index.xml","/CP072361_VMw.zip/metadata.zip/vmware.xml","/CP072361_VMw.zip/metadata.zip/vibs/CP072361-2976989503376219690.xml","/CP072361_VMw.zip/metadata.zip/bulletins/Smart-Component-CP072361_1.0.0-8.0.0.21495797.xml"],"Name":"CP072361.zip","SHA1Sum":"946ca6afb19a6ee94101163ef4a59e58fa3a690e","SHA256Sum":"516123b27c25890f9da4095ef7c57b4eee05542c2c47d98ece8227b58e099ad2","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-15B3-101715900246","a6b1a447-382a-5a4f-15B3-1015159000D3","a6b1a447-382a-5a4f-15B3-1015159000D4"],"TypeOfChange":"1","Version":"1.0.8","VibList":[{"Name":"CP072361","Version":"1.0.0-8.0.0.21495797"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecca403118","SWKey":"kmod-kernel-mft-mlnx","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecacb46dd0","SWKey":"kernel-mft-mlnx-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"","Requirement":[]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Mellanox MFT Driver is required and should already be active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Mellanox MFT Driver is required and should already be active","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec18f059b5","SWKey":"mft","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online Firmware Upgrade Utility (ESXi 8.0) for HPE Mellanox Ethernet only adapters","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"Mellanox_NIC","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4e9046babf2a48f69093440fd0","SupportedDevices":["a6b1a447-382a-5a4f-15b3-101715900246","a6b1a447-382a-5a4f-15b3-1015159000d3","a6b1a447-382a-5a4f-15b3-1015159000d4"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","A40","U46","A42","U46","A43","A43","A43","A41","A47","A48","U50","U47","A46","U47","U47","U47","U50","U46","HPE Apollo 2000 Gen10 Plus System","A42","U34","U34","U30","P89","U32","P89","U36","U22","U41","U40","U38","U38","HPE Apollo 6500 Gen10 Plus (Chassis)","U39","U19","U56","U61","U45","U25","U37","HPE ProLiant SL4500 Chassis","U39","HPE Apollo 6500 Gen10 System"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"BIOS - System ROM","ComponentLocation":"","CompsigCount":0,"DeviceClass":"aa148d2e-6e09-453e-bc6f-63baa5f5ccc4","Devices":{"Device":[{"DeviceName":"System BIOS - U38","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"U38_3.70_08_19_2026.signed.flash","InstallDurationSec":300,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"00000000-0000-0000-0000-000000000213","Version":"v3.70 (08/19/2026)"}]},"Files":[{"Checksum":[{"Filename":"U38_3.70_08_19_2026.fwpkg","SHA1Sum":"2ded19c5c1c01ee27c2b8cdbeeeda2c9625f4c53","SHA256Sum":"05e2a3c0b74a661c33272d5da181acf80ec441daafc063f93e2370106ac8c365","SHA512Sum":"b2cb081503bfda739d2c5bb2566e2ed5858cc5cd7c23b5709c2aafcfec89eb43d775f68b92d743a10b55e11fbb78e7819326660004b1e1093362737d2a8ff945"}],"ComponentSizeInKB":32824,"CompsigList":[],"FileList":["payload.json","U38_3.70_08_19_2026.signed.flash","U38_3.70_08_19_2026.xml"],"Name":"U38_3.70_08_19_2026.fwpkg","SHA1Sum":"2ded19c5c1c01ee27c2b8cdbeeeda2c9625f4c53","SHA256Sum":"05e2a3c0b74a661c33272d5da181acf80ec441daafc063f93e2370106ac8c365","SoftwarePlatforms":[],"TargetGUIDs":["00000000-0000-0000-0000-000000000213"],"TypeOfChange":"1","Version":"3.70_08-19-2026"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.0","OSVersion":{"Name":"VMware","Value":"5.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.1","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.1","OSVersion":{"Name":"VMware","Value":"5.1"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.0.3.9-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf961a5f4","SWKey":"char-hpcru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 5.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 5.5","OSVersion":{"Name":"VMware","Value":"5.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"5.5.4.1-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.0","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.0","OSVersion":{"Name":"VMware","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.5.8.0-1OEM"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HP CRU Driver for VMware ESXi 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP CRU Driver for VMware ESXi 6.5","OSVersion":{"Name":"VMware","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecbe6e85ad","SWKey":"hpe-cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"650.6.5.8"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"","SWKey":"cru-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"},{"Condition":"AlreadyActive","Description":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE CRU Driver Bundle Smart Component for ESXi 7.0 version 700.10.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"7.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec53c3d5a6","SWKey":"cru","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"700.10.16-1OEM.700.0.0.14828939"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant Integrated Lights-Out Management Interface Driver for Windows","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece65aa5f6","SWKey":"hpqilo3chif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec587429e7","SWKey":"cpqci","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HP Channel Interface Driver for VMWare","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Channel Interface Driver for VMWare","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecf1c92383","SWKey":"char-hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec2fe7fb84","SWKey":"hpe-ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Channel Interface Driver for VMware","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Channel Interface Driver for VMware","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecb1b2cabc","SWKey":"ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","DeviceGUID":"","Message":"HPE iLO Driver Bundle Smart Component for ESXi 7.0 version 700.10.1.0.16-1OEM.700.0.0.14828939 or greater is required and should be already active","OSVersion":{"Name":"VMware","Value":"*"},"RequirementGUID":"","SWKey":"ilo-driver","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"ROM Flash Firmware Package - HPE Apollo 2000 Gen10/HPE ProLiant XL170r/XL190r Gen10 (U38) Servers","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"U38","SWKeyExpectedPath":"firmware:system"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ff170d2635ae422fbdedac5faf","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U38","U38","U38","U38","U38"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57412 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957412A4121HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16d614e41595","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957412A4121HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16de14e41595","Version":"238.1.169.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57412 adapters","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"BCM238.1.169.0_BCM957412A4121HC.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":true,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14e4-16eb14e41595","Version":"238.1.169.0"}]},"Files":[{"Checksum":[{"Filename":"BCM238.1.169.0_BCM957412A4121HC.fwpkg","SHA1Sum":"ceaeab5970f72d0d56aeae7952c75acce12d1e53","SHA256Sum":"7e31d17c3184d9e277508b8fa018a79b3451bb320ef63730e7ddcb1753352f09","SHA512Sum":"e8cecf0efc5a3ddc0c03056ed17f4608e28fd728c77b852a1140319588d2b7be548c979874ae900c6efdaaae5579b9493edf8f391a8ec1ac1d9727ac191dfb87"}],"ComponentSizeInKB":1430,"CompsigList":[],"FileList":["BCM238.1.169.0_BCM957412A4121HC.HPb","BCM238.1.169.0_BCM957412A4121HC.xml","payload.json"],"Name":"BCM238.1.169.0_BCM957412A4121HC.fwpkg","SHA1Sum":"ceaeab5970f72d0d56aeae7952c75acce12d1e53","SHA256Sum":"7e31d17c3184d9e277508b8fa018a79b3451bb320ef63730e7ddcb1753352f09","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16de14e41595","a6b1a447-382a-5a4f-14e4-16eb14e41595"],"TypeOfChange":"1","Version":"238.1.169.0"}],"InstallationDependency":{},"Name":"Broadcom Firmware Package for BCM57412 adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"no","SWKeys":[{"Name":"BCM_NXE_57412_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a1d49d88b95b4d258bfe7dbd60","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d614e41595","a6b1a447-382a-5a4f-14e4-16eb14e41595","a6b1a447-382a-5a4f-14e4-16de14e41595"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0","16.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U77","U72","U70","A66","A66","A72"],"Type":"ComboFirmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Software - Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"cp072099.zip","SHA1Sum":"60f0ce76ef48a4cc5f82508d5e2baae67d2693ba","SHA256Sum":"091b5c4428c0eb3444448da8e396e0be332bcc93f33a948c1635dc122d0196e6","SHA512Sum":"2264f5964cb4a04fe6d00e926b2415e24b147b9ff1d20bc5fdf20ccb66f669904a966934a797ad71aed769081f96508acccc4f7decfb299289649ed724044a41"}],"ComponentSizeInKB":13625,"CompsigList":["cp072099.compsig"],"FileList":["/cp072099.xml","/MIS_bootbank_ssacli2_6.65.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.65.11.0-0.zip","/ssacli2-component_6.65.11.0-0.zip/index.xml","/ssacli2-component_6.65.11.0-0.zip/vendor-index.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip","/ssacli2-component_6.65.11.0-0.zip/vib20/ssacli2/MIS_bootbank_ssacli2_6.65.11.0-1OEM.900.0.24755229.vib","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vendor-index.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vmware.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/vibs/ssacli2--6784777076922694234.xml","/ssacli2-component_6.65.11.0-0.zip/metadata.zip/bulletins/ssacli2-component_6.65.11.0-0.xml"],"Name":"cp072099.zip","SHA1Sum":"60f0ce76ef48a4cc5f82508d5e2baae67d2693ba","SHA256Sum":"091b5c4428c0eb3444448da8e396e0be332bcc93f33a948c1635dc122d0196e6","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec20128a07","20a6e8e4-bf33-4c71-a6bf-d9ecb4d0bae4"],"TypeOfChange":"1","Version":"2026.07.01","VibList":[{"Name":"ssacli2","Version":"6.65.11.0-1OEM.900.0.24755229"}]}],"InstallationDependency":{},"Name":"Smart Storage Administrator (SSA) CLI Smart Component for ESXi 9.0 for Gen10/Gen10 Plus/Gen11 Controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"yes","SWKeys":[{"Name":"ssacli2-component:6.65.11.0-0","SWKeyExpectedPath":"software.component:vmware:zip"},{"Name":"ssacli2:6.65.11.0-1OEM.900.0.24755229","SWKeyExpectedPath":"software:vmware:zip"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ec21b21fb0ac426b98b388e6a0","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f159002dc","a6b1a447-382a-5a4f-9005-028f15900294","a6b1a447-382a-5a4f-103c-193f1590027f","a6b1a447-382a-5a4f-8086-a256159002f4","a6b1a447-382a-5a4f-8086-a206159002f2","a6b1a447-382a-5a4f-8086-a186159000e5","a6b1a447-382a-5a4f-103c-193f159000e4","a6b1a447-382a-5a4f-8086-a1d6159000e6","a6b1a447-382a-5a4f-8086-a206159000e5","a6b1a447-382a-5a4f-8086-a256159000e6","a6b1a447-382a-5a4f-9005-028f15900383","a6b1a447-382a-5a4f-9005-028f15900382","a6b1a447-382a-5a4f-9005-028f1590032e","a6b1a447-382a-5a4f-9005-028f15900381","a6b1a447-382a-5a4f-9005-028f159002db","422340a5-3939-4644-4237-342d07f65795","a6b1a447-382a-5a4f-8086-8d661590009d","a6b1a447-382a-5a4f-8086-8d061590009c","a6b1a447-382a-5a4f-103c-193f103c3381","a6b1a447-382a-5a4f-8086-a106159000c0","a6b1a447-382a-5a4f-8086-a107159000c0","a6b1a447-382a-5a4f-103c-3239103c21c5","a6b1a447-382a-5a4f-103c-3239103c21c1","a6b1a447-382a-5a4f-103c-3239103c21cb","a6b1a447-382a-5a4f-103c-3239103c21be","a6b1a447-382a-5a4f-103c-3239103c21cc","a6b1a447-382a-5a4f-103c-3239103c21c3","a6b1a447-382a-5a4f-103c-3239103c21c0","a6b1a447-382a-5a4f-103c-3239103c21c2","a6b1a447-382a-5a4f-103c-3239103c21ca","a6b1a447-382a-5a4f-103c-3239103c21bd","a6b1a447-382a-5a4f-103c-3239103c21c4","a6b1a447-382a-5a4f-103c-3239103c21cd","a6b1a447-382a-5a4f-103c-3239103c21c6","a6b1a447-382a-5a4f-103c-3239103c21c9","a6b1a447-382a-5a4f-103c-3239103c21c8","a6b1a447-382a-5a4f-103c-3239103c21bf","a6b1a447-382a-5a4f-103c-3239103c21c7","a6b1a447-382a-5a4f-103c-3239103c21ce"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U43","U41","U33","U44","U40","U45","U37","U38","U38","I43","I42","A42","U46","A42","U46","A43","A43","A43","U51","A47","A48","U50","U47","A46","U47","A48","U48","U47","U47","U50","U46","I44","U38","U38","U38","U40","U40","U39","A42","HPE Apollo 6500 Gen10 Plus (Chassis)","U46","I45","U63","U58","U59","U54","U54","U54","U63","A56","A56","A55","A55","U58","U58","U17","P85","P89","P89","P89","U20","U20","P86","U15","U15","U22","P92","P95","P99","U23","O42","HPE ProLiant XL770f Gen9 Server","U27","U25","U24","U18","U18","U21","U14","U14","U12","U13","U13","U18","Carbondale14","Carbondale14","U19","Carbondale14","HPE Apollo r2200 Gen9 12 LFF Configure-to-order Chassis","U14","HPE Apollo r2600 Gen9 24 SFF Configure-to-order Chassis","I40","I39","I40","I37","U57","U62","U65","U65","A66","U71","U71","A66","U68","U68","U72","U68"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - System","ComponentLocation":"","CompsigCount":1,"DeviceClass":"8e59d79d-ae28-4e35-8d63-3c0d75bee62e","Devices":{"Device":[{"DeviceName":"Server Platform Services Manageability Engine Firmware for t...","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"cp070622.zip","InstallDurationSec":600,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-8086-43e080867270","Version":"06.00.03.708"}]},"Files":[{"Checksum":[{"Filename":"cp070626.exe","SHA1Sum":"d6aab718a03ae58500dcd6d55866585b1b6df6b1","SHA256Sum":"5c50ab89830954251a24f2e810cb6804a50b5bb0f1b4ef2316b81509d4931c86","SHA512Sum":"e8f2f296dd1e5b4d28da07155d3410f30029b8b6ebfec589ebf8901f1a3b9ac25cbe9186edbdbe6f1adf1501c46d8d3b43d78304186c0a4865767f434f8a4af3"}],"ComponentSizeInKB":2863,"CompsigList":["cp070626.compsig"],"FileList":["cp070622.compsig","cp070622.zip","cp070626.xml","cpqsetup.exe","LICENSE.txt","payload.json","SecureFlash64.dll"],"Name":"cp070626.exe","SHA1Sum":"d6aab718a03ae58500dcd6d55866585b1b6df6b1","SHA256Sum":"5c50ab89830954251a24f2e810cb6804a50b5bb0f1b4ef2316b81509d4931c86","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-43e080867270"],"TypeOfChange":"1","Version":"06.00.03.708"}],"InstallationDependency":{},"Name":"Online ROM Flash Component for Windows x64 - Server Platform Services (SPS) Firmware for HPE ProLiant DL20 Gen10 Plus","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":600,"RebootRequired":"yes","SWKeys":[{"Name":"SPS_UEFI_Gen10","SWKeyExpectedPath":"firmware:sd:sps"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3a745adf440542eab82166c07b","SupportedDevices":[],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.3","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":true,"SupportedProducts":["U60","FTP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Software - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"MRStorageAdministrator-008.018.011.000-00.x86_64.rpm","SHA1Sum":"0d2ca8638b220e896f9725cde802ab9b0fb29ef4","SHA256Sum":"b2918f2f532dfaf0454bf55a1010f557577bd8d2d6954fed50aea9cbe6b1e799","SHA512Sum":"870b65165ad5f87a21f2e672bb50ee4cfdfe2da4703103911416fc5d74dfd2426ea9fd2e9def4fabc70536da13afa266a53090af5b4dbf854e726d77155d7d2d"}],"ComponentSizeInKB":32005,"CompsigList":["MRStorageAdministrator-008.018.011.000-00.x86_64.compsig"],"FileList":["./etc/init.d/LsiSASH","./opt/HPEMRSA/LSIStorageAuthority","./opt/HPEMRSA/LSIStorageAuthority/bin","./opt/HPEMRSA/LSIStorageAuthority/bin/LSA","./opt/HPEMRSA/LSIStorageAuthority/bin/libcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libcurl.so.4","./opt/HPEMRSA/LSIStorageAuthority/bin/libhttpcgi.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegclient.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegcommon.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegconfig.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegexportserver.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegindicationservice.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpeglistener.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegprovider.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libpegslp_client.so.1","./opt/HPEMRSA/LSIStorageAuthority/bin/libpluginmanager.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelib8.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibir-3.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libstorelibit.so","./opt/HPEMRSA/LSIStorageAuthority/bin/libutility.so","./opt/HPEMRSA/LSIStorageAuthority/bin/lsistorageauthority.service","./opt/HPEMRSA/LSIStorageAuthority/bin/mrsstorageauthority.service","./opt/HPEMRSA/LSIStorageAuthority/bin/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/bin/smtpServer","./opt/HPEMRSA/LSIStorageAuthority/bin/storelib8conf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconf.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/storelibconfit.ini","./opt/HPEMRSA/LSIStorageAuthority/bin/temp","./opt/HPEMRSA/LSIStorageAuthority/conf","./opt/HPEMRSA/LSIStorageAuthority/conf/LSA.conf","./opt/HPEMRSA/LSIStorageAuthority/conf/languages","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertparam.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/alertspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/healthspec.json","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr8_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_errors_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/mr_events_spec.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/languages/en-US/plugins_prop.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-current.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/config-default.json","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/eventcode8.ini","./opt/HPEMRSA/LSIStorageAuthority/conf/monitor/logs","./opt/HPEMRSA/LSIStorageAuthority/logs","./opt/HPEMRSA/LSIStorageAuthority/plugins","./opt/HPEMRSA/LSIStorageAuthority/plugins/libcacheinit.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libmonitor.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/librepository.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/libserverdiscovery.so","./opt/HPEMRSA/LSIStorageAuthority/plugins/pubKey.asc","./opt/HPEMRSA/LSIStorageAuthority/report","./opt/HPEMRSA/LSIStorageAuthority/server","./opt/HPEMRSA/LSIStorageAuthority/server/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/readme.txt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.crt","./opt/HPEMRSA/LSIStorageAuthority/server/conf/Sample_SSL_https/ssl.key","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/fastcgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/koi-win","./opt/HPEMRSA/LSIStorageAuthority/server/conf/mime.types","./opt/HPEMRSA/LSIStorageAuthority/server/conf/nginx.conf","./opt/HPEMRSA/LSIStorageAuthority/server/conf/scgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/uwsgi_params","./opt/HPEMRSA/LSIStorageAuthority/server/conf/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/README","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/geo2nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/koi-utf","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/unicode-to-nginx.pl","./opt/HPEMRSA/LSIStorageAuthority/server/contrib/unicode2nginx/win-utf","./opt/HPEMRSA/LSIStorageAuthority/server/docs","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES","./opt/HPEMRSA/LSIStorageAuthority/server/docs/CHANGES.ru","./opt/HPEMRSA/LSIStorageAuthority/server/docs/LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/OpenSSL.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/PCRE.LICENCE","./opt/HPEMRSA/LSIStorageAuthority/server/docs/README","./opt/HPEMRSA/LSIStorageAuthority/server/docs/zlib.LICENSE","./opt/HPEMRSA/LSIStorageAuthority/server/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/html","./opt/HPEMRSA/LSIStorageAuthority/server/html/50x.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/App_statusCode_description.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Configfile.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/Prop.json","./opt/HPEMRSA/LSIStorageAuthority/server/html/files/credits.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonltr.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/commonrtl.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-Chg-Personality1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE-LSA7_set_adjust_task_rate.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure1-InstallShieldWizardDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure2-PortConfigurationSettingsDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure3-DestinationFolderDialog.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_Figure4-ConfigureRangeOfEventsToGenerateAlertNotifications.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA8_set_task_priority.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Controller_Dashboard1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_NVMe_Thermal_Poll_Interval.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_Server_Dashboard_Nologin1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_alert_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_manage_power_save_settings.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_LSA_writecache_policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/HPE_changing_behavior_modes.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-EnableUnmapFeatureDuringVolumeCreation.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-FW-Activation-Status.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Factory-Defaults.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Known-Issues-and-WAs.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Restore-Factory-Defaults.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-Viewing-Protected-Drive-Groups.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA-device-reporting-order-hpe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ChangeDrive-Security.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure22-DriveLevelUnmapPropertiesWindow.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_Figure23-EnableOrDisableTheScsiUnmapFeature.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_ManagePCIe-Storage-Interface2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_UpdateFW_2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_drive_security2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_change_profile3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_cross_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_enable_drive_security_1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_expand_button_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_home_page_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_DG_remove_physical_drives_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_modify_vd_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_private IP Address.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_system_messages_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/LSA_tape_drive_7.4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/MSM_IR_OH_icon_Tape_drive.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/Replace-a-Missing-Drive.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/config-login-no-login-localhost-remote-access.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-available-drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume-add-phy-drive.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-OCE-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-expand-online-capacity-volume.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-drives.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-map-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-modify-physical-function.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function-info.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-physical-function.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-protected-arrays.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-drives.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-remove-map-volume.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-av2-show-protected-arrays.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-drive-power-control.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-drive-power-control.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-expand-online-capacity-vd.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-lsa-spin-down.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-managing-power-save-settings.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/hpe-op-phy-functions.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-auto-assign-policy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-device-reporting-order.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-help-auto-assign-policy.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-make-jbod-choices.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-manage-sid-ownership.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-physical-functions-operations.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa-spin-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_function_profile_mngmt.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_manage_sid_ownership.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/lsa_physical_function_properties_dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-hpe-nvram-clear.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr7-nvme-thermal-poll-interval.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/mr8-nvme-drive-format.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v10550932.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036741.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036763.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11036906.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11169464.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12028784.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049673.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12049745.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381616.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381645.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12381749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12382402.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385240.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385315.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385509.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385556.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385596.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385636.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385749.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385802.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385820.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385873.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385942.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12385973.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386067.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386091.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386305.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386355.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386372.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386753.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386772.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386809.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386877.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386894.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386967.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12386997.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387021.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387133.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387257.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387293.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12387319.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12397903.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398544.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398849.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398866.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398947.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12398977.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399034.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399082.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399120.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399154.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399181.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399198.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399366.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399408.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399445.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399502.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399583.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399626.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399825.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12399842.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400129.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400161.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400195.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400228.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400275.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400308.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400341.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400389.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400409.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400486.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400504.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400540.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400572.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12400670.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401028.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401045.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401221.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401253.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12401272.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12823262.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885328.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885363.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885418.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885449.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885609.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885659.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12885712.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v12973551.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13070587.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13254701.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v13292421.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v19331475.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v20608785.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v21853855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25001015.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25002298.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v25003980.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v26717125.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v8285855.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9157473.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9506612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9508081.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9894102.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895528.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895548.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895566.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895592.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9895612.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9896799.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/content/v9897068.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v11859440.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/help/megaraid/v12049588.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/custom.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/launchPage.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_OEM.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_en.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/message_es.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/js/response_loading.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/ServerNotReachable.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/97AB61D67CC8D4791C6CB34B01AEDD99.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/core/core.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/error-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/exclamation_mark.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/core/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/cssstyles.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/global.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/gwt.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n1.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n2.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n3.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/myriad-pro-n4.woff","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/css/slides.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ControllerDasboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LSA_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_ReadMe.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/LWM_UserGuide.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ManageServerHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/RemoteServerDiscoveryHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/ServerDashboardHelp.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/arrow-up-green.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/checkboxIcon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt1.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt2.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt3.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/cnt4.jpg","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/headbackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/mainlogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/next_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/prev_a.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide3.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/slide4.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/53EF515E4B68F4375CDAB62B8BF5DF72.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/integratedraid/integratedraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/integratedraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/editDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/save.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/saveDisable.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/59AE9E2C0EDDF3AAB8FA2CAAE04CA10B.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/managedserver/managedserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/managedserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/Plugin.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGBorder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/DGNameBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/background.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/cancel.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/checkbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/circles_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/closeBackground.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/corner_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/emboss_border.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/green_fill.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_copy.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/hborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/left-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/modify-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_last_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_arrow_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/next.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/prev.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/right-dots.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/uncheckbox.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/up-down.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/vborder_ie6.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/images/wrap_drive_graph.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/2EE840FAFCB91D1EAD07D1F6BA3F09A2.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/css/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/megaraid/megaraid.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/megaraid/style.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/Close.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/circles.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/critical.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/disableManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/discover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/edit.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/exsiLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/help.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/hostBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/langBoxicon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loading.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/loadingFail.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/need_attention.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/openEulerLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/optimal.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoAnolis.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/osLogoOpenCloud.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/password-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/question.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/refresh.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/remotediscover.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhel2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/rhelLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/search.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/serverNodeBackGround.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/startManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stopManage.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suse2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/suseLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/ubuntuLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vborder.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/vmware2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows1.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windows2.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/images/windowsLogo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/5968E56EAC86DEF4EEF6EFAC52E6C03D.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/6A0599278CD7FFE2A498A75DF283F7C3.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/9080802D95D23E48FEEEAF073F2133E8.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/B607368818C162A84762061F2C356C99.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/F341E372CEA1C0564EDD678439647050.cache.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/remoteserver/remoteserver.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/remoteserver/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/Server.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/hba_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/header_bg.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/info_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/jbod_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/logo.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/message_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_epd.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_jbod.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/mode_raid0.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_gradient_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_off.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/nav_triangle_on.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/notification_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/pdvd-icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/profile_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/raid_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/sds_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/setting_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/stripe-pattern.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/images/user_nav_icon_active.png","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/index.html","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/reset.css","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/5F36DB58B87376D92AE07C107220CAFC.cache.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/clear.cache.gif","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/compilation-mappings.txt","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.devmode.js","./opt/HPEMRSA/LSIStorageAuthority/server/html/ui/server/server/server.nocache.js","./opt/HPEMRSA/LSIStorageAuthority/server/logs","./opt/HPEMRSA/LSIStorageAuthority/server/logs/access.log","./opt/HPEMRSA/LSIStorageAuthority/server/logs/error.log","./opt/HPEMRSA/LSIStorageAuthority/server/nginx","./opt/HPEMRSA/LSIStorageAuthority/server/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/start.log","./opt/HPEMRSA/LSIStorageAuthority/server/temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/client_body_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/fastcgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/proxy_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/scgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/temp/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/0","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/1","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/2","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/3","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/4","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/5","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/6","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/7","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/8","./opt/HPEMRSA/LSIStorageAuthority/server/upload_files/9","./opt/HPEMRSA/LSIStorageAuthority/server/uwsgi_temp","./opt/HPEMRSA/LSIStorageAuthority/startupLSAUI.sh","./opt/HPEMRSA/LSIStorageAuthority/uninstaller.sh","./usr/lib/.build-id","./usr/lib/.build-id/13","./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6","./usr/lib/.build-id/13/26f38a48525e5bdc2072c19561b9cafb315bf6.1","./usr/lib/.build-id/25","./usr/lib/.build-id/25/3a216f8a29433104fef3f5835f0f84b6acd10c","./usr/lib/.build-id/27","./usr/lib/.build-id/27/d4c42718119005429054dafd6f28c527daed04","./usr/lib/.build-id/28","./usr/lib/.build-id/28/86229857c741873f745a6f19d6bb88e78e9c23","./usr/lib/.build-id/45","./usr/lib/.build-id/45/c89dd0ed41481f5aaf71b6d0dfb5fe7e86b263","./usr/lib/.build-id/49","./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623","./usr/lib/.build-id/49/4028c9a9226016ecc175ebf4ec7117a1384623.1","./usr/lib/.build-id/5e","./usr/lib/.build-id/5e/d4b97581cb36c65a2a3ef7dd9793c9e434b982","./usr/lib/.build-id/69","./usr/lib/.build-id/69/67b5a6b52135a69585c5d4de37f594b81a8a23","./usr/lib/.build-id/6c","./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f","./usr/lib/.build-id/6c/def86483c8a27af2d87aca5366a43c6be6961f.1","./usr/lib/.build-id/6f","./usr/lib/.build-id/6f/25d39fe93fbce3ec7b9856fe40fba91b4088b3","./usr/lib/.build-id/7a","./usr/lib/.build-id/7a/06b1924c8e057bb3ab50b07e25eed5994d7961","./usr/lib/.build-id/7f","./usr/lib/.build-id/7f/48add33807fd524598438751c6e8824e076c3e","./usr/lib/.build-id/84","./usr/lib/.build-id/84/bc4a60fa08e959f9cdf5e9d0e14207e79d3dcd","./usr/lib/.build-id/96","./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd","./usr/lib/.build-id/96/667e3a479452aa530e18037ea6e7d23cdc98cd.1","./usr/lib/.build-id/a5","./usr/lib/.build-id/a5/cab41eab92548c83894b5ab65b1099e676db7f","./usr/lib/.build-id/c4","./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a","./usr/lib/.build-id/c4/1f0cb1987fc3d10f59fd0acc70cd3b8be02b3a.1","./usr/lib/.build-id/d6","./usr/lib/.build-id/d6/8f1a74a48ef91989b2522a2059876facfdf263","./usr/lib/.build-id/db","./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157","./usr/lib/.build-id/db/bc7d120274ddf1d8f103c01e47292c82413157.1","./usr/lib/.build-id/df","./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986","./usr/lib/.build-id/df/5888317b628212c9cef2fc11bdb979fdf31986.1","./usr/lib/.build-id/e9","./usr/lib/.build-id/e9/1af91e89e3823df3862e83bc337a10e311fb57","./usr/lib/.build-id/eb","./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce","./usr/lib/.build-id/eb/105e053a56e8f602e58208a34bffa7ddb910ce.1","./usr/lib/.build-id/f2","./usr/lib/.build-id/f2/3c1b8ecd67eb89cd9705d7ccbce204e261c8c3","./usr/lib/.build-id/f2/3c1b8ecd67eb89cd9705d7ccbce204e261c8c3.1","./usr/lib/.build-id/f7","./usr/lib/.build-id/f7/f1a06a9fd6ef397a21902d59cc0428a672f386","./usr/share/smartupdate/MRStorageAdministrator/component.xml"],"Name":"MRStorageAdministrator-008.018.011.000-00.x86_64.rpm","SHA1Sum":"0d2ca8638b220e896f9725cde802ab9b0fb29ef4","SHA256Sum":"b2918f2f532dfaf0454bf55a1010f557577bd8d2d6954fed50aea9cbe6b1e799","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ec7b3f1da5"],"TypeOfChange":"1","Version":"8.18.11.0"}],"InstallationDependency":{},"Name":"HPE MegaRAID Storage Administrator for RHEL9 ,SLES15 and SLES16 (HPE MRSA for MR Controllers)","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"MRStorageAdministrator","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_a03b3fe1be3845b8ada544044b","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900328","a6b1a447-382a-5a4f-1000-10e215900325","a6b1a447-382a-5a4f-1000-10e215900329","a6b1a447-382a-5a4f-1000-10e2159003c8","a6b1a447-382a-5a4f-1000-10e215900326","a6b1a447-382a-5a4f-1000-10e215900293","a6b1a447-382a-5a4f-1000-10e21590032a","a6b1a447-382a-5a4f-1000-10e21590032b","a6b1a447-382a-5a4f-1000-10e21590032c","a6b1a447-382a-5a4f-1000-10e215900448","a6b1a447-382a-5a4f-1000-00b315900453"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A55","A55","A56","A56","U58","U54","U54","U54","U58","U63","U63","U59","U46","U30","A42","U46","U32","A43","A43","A42","U61","U60","U65","U65","A58","U72","I46","U68","U68","U68","HPE ProLiant DL380m Gen12","U71","U71","U72","A66","A66","U68","A59","U71","A72","U84"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SAS Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB008000JWJRQ","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-304a574a5251","Version":"HPD9"},{"DeviceName":"MB006000JWJRP","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06scHPD9.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-304a574a5250","Version":"HPD9"}]},"Files":[{"Checksum":[{"Filename":"firmware-hdd-faf39e0ff7-HPD9-10.1.x86_64.rpm","SHA1Sum":"14895babd87a1d3beeb4903dad329d8ba7c64aa7","SHA256Sum":"9568457a6d9c1c2bc2bf74ca65f0ad62bafa269e08a1f5cbaa296c074e2f65cf","SHA512Sum":"1a66a8cd84a00de0cca7eb4d00e06d959b7a28ffe2b764e2d7c9c9c99bb94c444d9e9356e6e3fb103d88308f3132e0d35b8a0e5272556309cc193d4eaf4c500e"}],"ComponentSizeInKB":5039,"CompsigList":["firmware-hdd-faf39e0ff7-HPD9-10.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/CP068857.xml","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/TAMG06scHPD9.REL","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-hdd-faf39e0ff7-HPD9-10.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068857.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068857.scexe"],"Name":"firmware-hdd-faf39e0ff7-HPD9-10.1.x86_64.rpm","SHA1Sum":"14895babd87a1d3beeb4903dad329d8ba7c64aa7","SHA256Sum":"9568457a6d9c1c2bc2bf74ca65f0ad62bafa269e08a1f5cbaa296c074e2f65cf","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"TypeOfChange":"1","Version":"HPD9"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Linux (x64) - MB008000JWJRQ and MB006000JWJRP Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB008000JWJRQ","SWKeyExpectedPath":"firmware:sd:SAS"},{"Name":"MB006000JWJRP","SWKeyExpectedPath":"firmware:sd:SAS"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_026217c0626d4029b3c39b733e","SupportedDevices":["4d2340a5-3042-3830-3030-304a574a5251","4d2340a5-3042-3630-3030-304a574a5250"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","8.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - SATA Storage Disk","ComponentLocation":"","CompsigCount":1,"DeviceClass":"F6DE0320-2E0F-489A-B238-6DD8AE7C3811","Devices":{"Device":[{"DeviceName":"MB006000GWJRR","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3630-3030-3047574a5252","Version":"HPG6"},{"DeviceName":"MB008000GWJRT","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"TAMG06ACHPG6.REL","InstallDurationSec":300,"Order":1,"ResetRequired":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4d2340a5-3042-3830-3030-3047574a5254","Version":"HPG6"}]},"Files":[{"Checksum":[{"Filename":"cp068755.exe","SHA1Sum":"cc2c8c496b4f8a81b72dff444491b102b404631e","SHA256Sum":"1232aaa1c1f0ad62e08629437e188125e6711e22c7cef9cfc53927ce53d065dd","SHA512Sum":"723573005669a3cf64ea96a45db0c39a92ead6fda9ff68c0b07dde67b73eee52569bcad9095afc9e4841344705cc6312f95767af04178415c85ece3b8796d071"}],"ComponentSizeInKB":3200,"CompsigList":["cp068755.compsig"],"FileList":["cp068755.xml","cpqsetup.exe","mnv_cli.exe","payload.json","setup.dll","TAMG06ACHPG6.REL"],"Name":"cp068755.exe","SHA1Sum":"cc2c8c496b4f8a81b72dff444491b102b404631e","SHA256Sum":"1232aaa1c1f0ad62e08629437e188125e6711e22c7cef9cfc53927ce53d065dd","SoftwarePlatforms":[],"TargetGUIDs":["4d2340a5-3042-3630-3030-3047574a5252","4d2340a5-3042-3830-3030-3047574a5254"],"TypeOfChange":"1","Version":"HPG6"}],"InstallationDependency":{},"Name":"Online HDD/SSD Flash Component for Windows (x64) - MB006000GWJRR and MB008000GWJRT Drives","PackageFormat":"","PerDeviceInstallTimeSeconds":120,"RebootRequired":"no","SWKeys":[{"Name":"MB006000GWJRR","SWKeyExpectedPath":"firmware:sd:SATA"},{"Name":"MB008000GWJRT","SWKeyExpectedPath":"firmware:sd:SATA"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_88b39410f2fd41e3a7c608a388","SupportedDevices":["4d2340a5-3042-3830-3030-3047574a5254","4d2340a5-3042-3630-3030-3047574a5252"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":[],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]}],"Prerequisites":[{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-nxe_226.1.107000-1.1_amd64.deb","SHA1Sum":"a337929c31c9a16771833fba8c4a03d6b0ee7d8d","SHA256Sum":"ab98326d2081e30c5fe3f59a458394f7fd629569784041fd72b5214ed4d1adf8","SHA512Sum":"bb3e82e983cd6e473101f573272deb38f52aef6024ff712a9b2ed0778bb8b22488aaf20d1aa7b750027d758461c2fb9b77805eec246a92c0ec09fbc9df837737"}],"ComponentSizeInKB":1311,"CompsigList":["firmware-nic-bcm-nxe_226.1.107000-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/CP068813.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/CP068813.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068813.scexe","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068813.scexe"],"Name":"firmware-nic-bcm-nxe_226.1.107000-1.1_amd64.deb","SHA1Sum":"a337929c31c9a16771833fba8c4a03d6b0ee7d8d","SHA256Sum":"ab98326d2081e30c5fe3f59a458394f7fd629569784041fd72b5214ed4d1adf8","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fb1b62b98ea044789fa1f3c146","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","U50","U64"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860005","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.fwpkg","SHA1Sum":"8340791f033723a38702b6ab59c68f3522181df9","SHA256Sum":"76a117c2c99fdda0d22fc2d2fddda6058579039eab6c4a2a7e78ecbcdd1b028b","SHA512Sum":"3420fab3d0c4d08de96f53d4dfdd4e83d9b34ead37f738fc3ff52ac03f1df0339e5f8326912c45f72fa332e3f79a2f6985b1b6b82f6fa7a7929460632ddb26ec"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.HPb","HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.xml","payload.json"],"Name":"HPE_E810_XXVDA2_SD_OCP_4p20_NCSIwPLDMoMCTP_80017787.fwpkg","SHA1Sum":"8340791f033723a38702b6ab59c68f3522181df9","SHA256Sum":"76a117c2c99fdda0d22fc2d2fddda6058579039eab6c4a2a7e78ecbcdd1b028b","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860005"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_51458cdc933e445a85a609c281","SupportedDevices":["a6b1a447-382a-5a4f-8086-159b80860005"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":0,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_148.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Files":[{"Checksum":[{"Filename":"ilo5_148.fwpkg","SHA1Sum":"4c4d88b03e90aa72a7431af3e45d5e6b264b2a2d","SHA256Sum":"48e02049b5a8acf552f82b668bc860d41e1ec7910e572a5820b04224a296026c","SHA512Sum":"663e9acb6419408de6c6eb8f4c5ecf22631b264440d9a38b9d13e692e45c31bfec792ed78d3bc2a44587bf257ee1b126ff1f7a701a35da592e595200bfe04ff3"}],"ComponentSizeInKB":32802,"CompsigList":[],"FileList":["ilo5_148.bin","ilo5_148.xml","payload.json","readme.txt"],"Name":"ilo5_148.fwpkg","SHA1Sum":"4c4d88b03e90aa72a7431af3e45d5e6b264b2a2d","SHA256Sum":"48e02049b5a8acf552f82b668bc860d41e1ec7910e572a5820b04224a296026c","SoftwarePlatforms":[],"TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"0","Version":"1.48"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Firmware Package - HPE Integrated Lights-Out 5","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f0bb94c6dff64cb39c8fb14c2d","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["6.7","6.5","6.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U40","U39","U45","U37","U38","U38","O43","U38","U38","U38","U40","U39","I43","I42","U31","U31","U40","A42","U46","U46","A43","U51","U47","A46","A45","U47","U47","U50","I44"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"}]},"Files":[{"Checksum":[{"Filename":"CP070871.zip","SHA1Sum":"5cfdd0fe420cb5d367cec7836269095162439008","SHA256Sum":"9ecd22a5b03d8c5cc9c7f23d63ed1250a3aed12fd9dc7c4d9bb37931fb491993","SHA512Sum":"fa70b52be472f2a700b3bc9f9c4c3d3fe6c823b911c997b5ee6dde0a7f65081d2164607aad2ccbad490f51297830c257d178fa7773fbcc9b67283323b9432e23"}],"ComponentSizeInKB":23937,"CompsigList":["CP070871.compsig"],"FileList":["/CP070871_BUILD_8.data","/CP070871.vmexe64","/CP070871.vmfile","/CP070871_VMw.zip","/CP070871.xml","/payload.json","/CP070871_VMw.zip/index.xml","/CP070871_VMw.zip/vendor-index.xml","/CP070871_VMw.zip/metadata.zip","/CP070871_VMw.zip/vib20/CP070871/HPE_bootbank_CP070871_5.61.8-8.0.0.20613240.vib","/CP070871_VMw.zip/metadata.zip/vendor-index.xml","/CP070871_VMw.zip/metadata.zip/vmware.xml","/CP070871_VMw.zip/metadata.zip/vibs/CP070871--790202062578980553.xml","/CP070871_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070871_5.61.8-8.0.0.20613240.xml"],"Name":"CP070871.zip","SHA1Sum":"5cfdd0fe420cb5d367cec7836269095162439008","SHA256Sum":"9ecd22a5b03d8c5cc9c7f23d63ed1250a3aed12fd9dc7c4d9bb37931fb491993","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654"],"TypeOfChange":"1","Version":"5.61","VibList":[{"Name":"CP070871","Version":"5.61.8-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for VMware ESXi - HPE Smart Array P816i-a,P416ie-m,P408i-p, P408e-p, P408i-a,P408i-c,P204i-c,E208i-p, E208e-p, E208i-a, P208i-c SR Gen10","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_477691debf2c4b71a008c01eed","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U39","U45","U37","U38","U38","O43","U40","U39","I43","I42","U48","A43","A42","U46","U46","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","A42","A43","A43","A42","HPE Apollo 2000 Gen10 Plus System","U61","U60","U46","U54","I45","U54","U54","U63","U63","A56","A55","A55","A56","U58","U59","U57","U65","U65","U62","U58","U58"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-f7c07bdbbd-5.61-8.1.x86_64.rpm","SHA1Sum":"e46deec6f2d783539a47ce9259e9b0a93d0de335","SHA256Sum":"499fa2cf9da481fc5584320e0997620674ffacf2decb0a2332b31d33ccbe42b9","SHA512Sum":"3444eb4225711ec57885d59e65e833653fe0c0f3feb475f0ffe1784978d6dc6b90ed45a2e93016a5b41f895283d07bf082b7afce9f1dbf6c8c0ecea63a2d6810"}],"ComponentSizeInKB":8790,"CompsigList":["firmware-smartarray-f7c07bdbbd-5.61-8.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/CP068828.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/HPE_luxor_5.61.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-f7c07bdbbd-5.61-8.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068828.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068828.scexe"],"Name":"firmware-smartarray-f7c07bdbbd-5.61-8.1.x86_64.rpm","SHA1Sum":"e46deec6f2d783539a47ce9259e9b0a93d0de335","SHA256Sum":"499fa2cf9da481fc5584320e0997620674ffacf2decb0a2332b31d33ccbe42b9","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652"],"TypeOfChange":"1","Version":"5.61"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Linux (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c4d82931ebd84881883ae3cc11","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U39","U45","U37","U38","U38","O43","U40","U39","I43","I42","U48","A43","A42","U46","U46","A47","A48","U47","A46","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","U47","U60","U61","U65","U65","U57","U58","U58","I45","A56","U59","U63","U58","U54","U54","U54","U63","A55","A56","A55","U62"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159b80860003","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.fwpkg","SHA1Sum":"6b7e92433f5befb184c38a3242a3952589f829f7","SHA256Sum":"7f10e350c6a49e2c35438568d9c725019f956d0fc9bc90061900a23e4ee43e12","SHA512Sum":"d820ef1dec96b9522d83da9208d0b5cd6af1cd363649db34e839db3a29d22bd9c4abcb256cce7cbec65951082afdaae4fb1950a9ec081f0b45b738d5ce673a96"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.HPb","HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.xml","payload.json"],"Name":"HPE_E810_XXVDA2_SD_4p20_PLDMoMCTP_8001778C.fwpkg","SHA1Sum":"6b7e92433f5befb184c38a3242a3952589f829f7","SHA256Sum":"7f10e350c6a49e2c35438568d9c725019f956d0fc9bc90061900a23e4ee43e12","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159b80860003"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8dec9b5d239f4e5ca376e1076e","SupportedDevices":["a6b1a447-382a-5a4f-8086-159b80860003"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4T adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15938086000e","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.fwpkg","SHA1Sum":"54cd7f3128875f7856d8443d44c50bc94ffb32a0","SHA256Sum":"3c1207be8dc30c201ec165e7508b8b9382dd960c3e447590051eb9fad52a0ff1","SHA512Sum":"f0edd17d1a5014341e2f4d6ec08d630ab5d308d574d9dcf797a0de1a2ca0e1bf5ff17c0ca483212ac29d2eb310090af100d8796a1ea156fb1968ee95eac5fb9c"}],"ComponentSizeInKB":10272,"CompsigList":[],"FileList":["HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.HPb","HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.xml","payload.json"],"Name":"HPE_E810_XXV4T_O_SEC_4p20_PLDMoMCTP_8001778B.fwpkg","SHA1Sum":"54cd7f3128875f7856d8443d44c50bc94ffb32a0","SHA256Sum":"3c1207be8dc30c201ec165e7508b8b9382dd960c3e447590051eb9fad52a0ff1","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000e"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4T_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_0ffd3d93f4e64e7d824fb7e99c","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["8.0","9.0","15.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-qlogic-flq-8.55.12-3.1.x86_64.rpm","SHA1Sum":"58c01c01acc2a32ab7eafad836103837f0558713","SHA256Sum":"cc20972f73044357183a35039caee0db207c20b542ffa35fae68601255f7b671","SHA512Sum":"343b267badd7f3e5291be35e4ece717751a2c900ef7bb50e04aaf25ada949a69ba9c4f23fa336a7151ae3ae4e0c0da4106ffea38d7309cdf3b0036dc50c312a6"}],"ComponentSizeInKB":2124,"CompsigList":["firmware-nic-qlogic-flq-8.55.12-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/CP061237.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/CP061237.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/nic_fw/ql_hp_ah_mbi_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-qlogic-flq-8.55.12-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP061237.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP061237.scexe"],"Name":"firmware-nic-qlogic-flq-8.55.12-3.1.x86_64.rpm","SHA1Sum":"58c01c01acc2a32ab7eafad836103837f0558713","SHA256Sum":"cc20972f73044357183a35039caee0db207c20b542ffa35fae68601255f7b671","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4f7626fc8ae84aa7aa653c82a1","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","A40","P89","P89","A41","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR216i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032c","Version":"52.26.3.5487"}]},"Files":[{"Checksum":[{"Filename":"CP070859.zip","SHA1Sum":"e5b6b273e95c006682a526f7010eeca4b174a026","SHA256Sum":"92f05e066cdbca10c5bc2b6356c5a8c8fa7adb693da1c629b532131589447e9a","SHA512Sum":"8c13247ce36d1d2f707a1959a9d8f972d998b3d8cd5b03f8c85b3dc305f0d4d9c3a55120f8cc8f966a2347b30822ce3f84b7f588de590e4ebf6fb0e36d75f0b2"}],"ComponentSizeInKB":12765,"CompsigList":["CP070859.compsig"],"FileList":["/CP070859_BUILD_3.data","/CP070859.vmexe64","/CP070859.vmfile","/CP070859_VMw.zip","/CP070859.xml","/payload.json","/CP070859_VMw.zip/index.xml","/CP070859_VMw.zip/vendor-index.xml","/CP070859_VMw.zip/metadata.zip","/CP070859_VMw.zip/vib20/CP070859/HPE_bootbank_CP070859_52.26.3.5487.3-8.0.0.20613240.vib","/CP070859_VMw.zip/metadata.zip/vendor-index.xml","/CP070859_VMw.zip/metadata.zip/vmware.xml","/CP070859_VMw.zip/metadata.zip/vibs/CP070859--8866966811280889856.xml","/CP070859_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070859_52.26.3.5487.3-8.0.0.20613240.xml"],"Name":"CP070859.zip","SHA1Sum":"e5b6b273e95c006682a526f7010eeca4b174a026","SHA256Sum":"92f05e066cdbca10c5bc2b6356c5a8c8fa7adb693da1c629b532131589447e9a","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032c"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP070859","Version":"52.26.3.5487.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-a Gen10 Plus Tri Mode Controller","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"032C1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_1cbb1c26de6f4bb7bb3b176396","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032c"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","U30","U32","A42","A43","A43","U61","U60","SPP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"cp069754.exe","SHA1Sum":"3c19f6f6a393d21c224c378f7da3d8e2665f1fec","SHA256Sum":"e86be90d623a7b913d77af5ac79ae6d5be70c848086592cb06e31c8d9b00d20f","SHA512Sum":"92794a063702ef82b179d15487e5c1364bfe18437ca9d811b6d6aae0f9578622aad2a208324c66c0574951d7f79d5c700d91ba3062fd24e2a45927e0328e6c9d"}],"ComponentSizeInKB":3083,"CompsigList":["cp069754.compsig"],"FileList":["cp069754.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_ah_mbi_open_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp069754.exe","SHA1Sum":"3c19f6f6a393d21c224c378f7da3d8e2665f1fec","SHA256Sum":"e86be90d623a7b913d77af5ac79ae6d5be70c848086592cb06e31c8d9b00d20f","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12"}],"InstallationDependency":{},"Name":"Marvell FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_5d468adc62504bb6a685fd6edf","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","U46","U38","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-is-marvell-flq-8.55.12-3.1.x86_64.rpm","SHA1Sum":"bc71c2e0a764b827df29c5a4628c5d5a30d140cb","SHA256Sum":"92bee08435d7cd4f24fbb8e665b31f445c240e51ce21aef953567a9c10fd2d29","SHA512Sum":"e709b769e482c2d817458719553be5a68e983731de45357d61958226c9cc7d4fbf2866656d2818a36d65d334a522a900b872509ffaaa9285b133dd6fd42e5c0a"}],"ComponentSizeInKB":2168,"CompsigList":["firmware-nic-is-marvell-flq-8.55.12-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/CP061236.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/CP061236.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs/libqlgc_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/deps/libs/libtcl8.3.so","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/nic_fw/ql_ah_mbi_open_8.55.12.bin","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-is-marvell-flq-8.55.12-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP061236.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP061236.scexe"],"Name":"firmware-nic-is-marvell-flq-8.55.12-3.1.x86_64.rpm","SHA1Sum":"bc71c2e0a764b827df29c5a4628c5d5a30d140cb","SHA256Sum":"92bee08435d7cd4f24fbb8e665b31f445c240e51ce21aef953567a9c10fd2d29","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12"}],"InstallationDependency":{},"Name":"Marvell FastLinQ Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_df0d2e84414545c18a181d95d2","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","U46","U38","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159380860005","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.fwpkg","SHA1Sum":"77bcc81598acc820859e00b84ec36faf529522a3","SHA256Sum":"b2beae73117355f6488f71a02518a5c2bb333ebaf7122a0dd41ecfbf814d2b58","SHA512Sum":"c838ab2aa3f4dabb6daccb3ade34bb47de32f63e3633e245d9b7e0e04bf4188f6e3ab81da96cd34475a0a6b7bf8a33290ab02e09d06c046c6bb057f315368f34"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.HPb","HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.xml","payload.json"],"Name":"HPE_E810_XXVDA4_FH_4p20_PLDMoMCTP_80017789.fwpkg","SHA1Sum":"77bcc81598acc820859e00b84ec36faf529522a3","SHA256Sum":"b2beae73117355f6488f71a02518a5c2bb333ebaf7122a0dd41ecfbf814d2b58","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159380860005"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fe74ccfcd503410b98d0aedd67","SupportedDevices":["a6b1a447-382a-5a4f-8086-159380860005"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"CP070642.zip","SHA1Sum":"55b7207da30751741fb70fcabb2cff38e0b0b446","SHA256Sum":"71b1fe1e1083564a3be027f309b7253da376684ef86257bccf8015c2fa17b4e0","SHA512Sum":"4870eb749b741c8e3e305e1339d8ead4db30d68ed3214cde101dfe68f2904ed23c348694508f42d8533dd2c54fccfb10118fd4a5a00a829e76c343dfc56356a8"}],"ComponentSizeInKB":30683,"CompsigList":["CP070642.compsig"],"FileList":["/CP070642_BUILD_7.data","/CP070642.vmexe64","/CP070642.vmfile","/CP070642_VMw.zip","/CP070642.xml","/payload.json","/CP070642_VMw.zip/index.xml","/CP070642_VMw.zip/vendor-index.xml","/CP070642_VMw.zip/metadata.zip","/CP070642_VMw.zip/vib20/CP070642/HPE_bootbank_CP070642_8.55.12.7-8.0.0.20613240.vib","/CP070642_VMw.zip/metadata.zip/vendor-index.xml","/CP070642_VMw.zip/metadata.zip/vmware.xml","/CP070642_VMw.zip/metadata.zip/vibs/CP070642-6122126821504098736.xml","/CP070642_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070642_8.55.12.7-8.0.0.20613240.xml"],"Name":"CP070642.zip","SHA1Sum":"55b7207da30751741fb70fcabb2cff38e0b0b446","SHA256Sum":"71b1fe1e1083564a3be027f309b7253da376684ef86257bccf8015c2fa17b4e0","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12","VibList":[{"Name":"CP070642","Version":"8.55.12.7-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-1 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfc93be64","SWKey":"qlgc-fastlinq-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-1"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.6"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50GbE driver version 8.74.6.0-5 or greater is required and should be already active for this firmware update. ","OSVersion":{"Name":"rhel","Value":"9.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd6456294","SWKey":"kmod-qlgc-fastlinq","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.74.6.0-5"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 6.0.402.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"MRVL-E4-CNA-Driver-Bundle","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"6.0.402.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6a25bd0a","SWKey":"qedf","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.62.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecd558d67b","SWKey":"qedrntv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.62.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 3.71.73.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec89e84beb","SWKey":"qedentv","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"3.71.73.0-1OEM.800.1.0.20613240"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Synergy QLogic FastLinQ 10/25/50 GbE Multifunction Driver 2.74.1.0-1OEM.800.1.0.20613240 or greater is required and should be already active for VMware vSphere 6.5","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec5685b43a","SWKey":"qedi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.74.1.0-1OEM.800.1.0.20613240"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLOGIC_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fd12209b390a4e6d8a9345d202","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","9.0","8.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","A40","P89","P89","A41","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"}]},"Files":[{"Checksum":[{"Filename":"cp069751.exe","SHA1Sum":"de44dd46826c0149e22f30684eb9dd42a32f0b64","SHA256Sum":"ba9f333a627b6efb0ad6dc0128dfbf4380f38040314ff1e3e68f2ee3b032e447","SHA512Sum":"36d7e1c6ef09eb8f95664e3deddcb3fd616844d1801ae4a2135136be91c841cd449cd622cb824a0303ff8538b36b3d271c99947b25c4be8175cf2e75f0488c45"}],"ComponentSizeInKB":9678,"CompsigList":["cp069751.compsig"],"FileList":["bcmefwupg.exe","brcm_hpfwupg.dll","brcm_hp_eventlog.dll","cp069751.xml","cpqsetup.exe","FW/","FW/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","FW/535T-2x10-14E4-16D8-1590-020C.PKG","FW/536I-2x10-14E4-16D6-1590-0230.pkg","FW/537SFP-2x10-14E4-16D7-1590-02C3.pkg","FW/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","FW/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","FW/631SFP28-2x25-14E4-16D7-1590-020E.PKG","FW/firmware.json","ja/","ja/NICOFUT.chm","libxml2.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp069751.exe","SHA1Sum":"de44dd46826c0149e22f30684eb9dd42a32f0b64","SHA256Sum":"ba9f333a627b6efb0ad6dc0128dfbf4380f38040314ff1e3e68f2ee3b032e447","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EE15900212"],"TypeOfChange":"1","Version":"226.1.107000"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Driver for Windows Server is required and should be already active","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec919626a4","SWKey":"bnxtnd.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180414e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41593","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41594","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16eb14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec14e41597","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41598","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed14e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d814e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16de14e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-180114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d614e41595","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee14e41592","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d714e41596","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107.0 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-175114e41599","SWKey":"bcmefwupg.exe","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107.0"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"bcmefwupg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_21283c052dce4f2493e243981f","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ee15900212"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","A40","U30","U32","A41","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","O43","U39","U26","U64"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Files":[{"Checksum":[{"Filename":"cp069579.exe","SHA1Sum":"e7cb59b4f22da4c146aada4422c107f7a8b2b797","SHA256Sum":"aefb8493fd2f449db2758db28f2c13c76ffe8f7901a4c4ae13acbefbe4b6b137","SHA512Sum":"54d919f78904476ead7a45fd65c9e8e53293da9603b3db3d3e1dd0975b4825a6749c3e583576b527a5c64e456dd0eca4c64ac0ec4141d12a7b1fd192a44a7742"}],"ComponentSizeInKB":1733,"CompsigList":["cp069579.compsig"],"FileList":["cp069579.xml","cpqsetup.exe","HPE_NS204i_1.2.14.1018.bin","mnv_cli.exe","payload.json","setup.dll"],"Name":"cp069579.exe","SHA1Sum":"e7cb59b4f22da4c146aada4422c107f7a8b2b797","SHA256Sum":"aefb8493fd2f449db2758db28f2c13c76ffe8f7901a4c4ae13acbefbe4b6b137","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"InstallationDependency":{},"Name":"Online Firmware Flash for Windows - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_bc87722faee84be4a9d5069381","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-22411590030e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","U30","U32","A43","U41","U33","U46","U47","A46","U47","U50","I44","U46","U40","U39","A47","A48","A42","A43","A43","U43","A42","U44","U48","I45","U54","U54","U54","U63","U63","A55","A56","A56","A55","U59","U58","U58","U58","H10","H10","H10","I46","U69","U69","U70","U70"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860006","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.fwpkg","SHA1Sum":"93879152515d558b14687a6a16f59a5c0893ec0d","SHA256Sum":"8b4a3f8959ffea3feb8881faf445daf349f93179dcd65fa78c98ad5abd1566b5","SHA512Sum":"ab368c2f33e10993a1f20d54566e17d1d1362866c735026351d1102327804b9fd95040a52af64c747a56e4371c223e23d418b19bdc851d4ac8f87a2233c7fa97"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.HPb","HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.xml","payload.json"],"Name":"HPE_E810_CQDA2_OCP_4p20_NCSIwPLDMoMCTP_80017783.fwpkg","SHA1Sum":"93879152515d558b14687a6a16f59a5c0893ec0d","SHA256Sum":"8b4a3f8959ffea3feb8881faf445daf349f93179dcd65fa78c98ad5abd1566b5","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860006"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_CQ2OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2c59babb0feb45a28cbb8082d3","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860006"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_148.bin","InstallDurationSec":240,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Files":[{"Checksum":[{"Filename":"cp070139.exe","SHA1Sum":"eb1bc70dac2542fad3208d595b311f7d59d60505","SHA256Sum":"e2a1cdebe8aeeae1439eb454f74d8123e23de5581bc617ed0f51045aa289894e","SHA512Sum":"ec1b063d3b9a798d094778a7b977e2c7b6911333bf4666ed1b00819f32c5c3b48fc1c34ed83991b0441e0e58d946219ec71e5481e7036811c03ac84ba374a0b9"}],"ComponentSizeInKB":17462,"CompsigList":["cp070139.compsig"],"FileList":["cp070139.xml","cpqsetup.exe","ilo5_148.bin","LICENSE.txt","payload.json","readme.txt","SecureFlash64.dll"],"Name":"cp070139.exe","SHA1Sum":"eb1bc70dac2542fad3208d595b311f7d59d60505","SHA256Sum":"e2a1cdebe8aeeae1439eb454f74d8123e23de5581bc617ed0f51045aa289894e","SoftwarePlatforms":[],"TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"1","Version":"1.48"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Windows x64 - HPE Integrated Lights-Out 5","PackageFormat":"Windows","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_47c837c7bc774252a1748f8034","SupportedDevices":["a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103c-3307159000e4"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["6.1","6.3","6.2","6.2","6.3","10.0","10.0.17600.18999","6.0","6.0","5.1","5.2","10.0","10.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U40","U39","U45","U37","U38","U38","O43","U38","U38","U38","U40","U39","I43","I42","U31","U31","U40","U46","U46","U47","A46","U47","U47","U50","I44","A42","U51","A45"],"Type":"Firmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Files":[{"Checksum":[{"Filename":"firmware-nic-bcm-nxe-226.1.107000-2.1.x86_64.rpm","SHA1Sum":"36dfe0e391765fd2ac85c7d0b65899477a76ef28","SHA256Sum":"84deef16f9de9a52ea96971958446c5f44d1493311252312c9481b0f17647189","SHA512Sum":"e886f027b61bdbf23cda5f835e0bb8a179101152ec9dcf6c5c138e2e1a27cc7ac23a7e732fd7729b97690a46e4ea8dd1b2643a223497bfec59d2a180a711f88c"}],"ComponentSizeInKB":7328,"CompsigList":["firmware-nic-bcm-nxe-226.1.107000-2.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/CP063801.txt","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/CP063801.xml","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps/libs","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/deps/libs/libbrcm_hpfwupg.so","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/535T-2x10-14E4-16D8-1590-020C.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/536I-2x10-14E4-16D6-1590-0230.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/537SFP-2x10-14E4-16D7-1590-02C3.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/nic_fw/631SFP28-2x25-14E4-16D7-1590-020E.PKG","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-nic-bcm-nxe-226.1.107000-2.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP063801.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP063801.scexe"],"Name":"firmware-nic-bcm-nxe-226.1.107000-2.1.x86_64.rpm","SHA1Sum":"36dfe0e391765fd2ac85c7d0b65899477a76ef28","SHA256Sum":"84deef16f9de9a52ea96971958446c5f44d1493311252312c9481b0f17647189","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for Linux x86_64","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_8526d39348f74098b531f4e304","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["7.0","12.0","15.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","U50","U64"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM235.1.220.0_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41599","Version":"235.1.220.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM235.1.220.0_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41599","Version":"235.1.220.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM235.1.220.0_BCM957504-P425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41599","Version":"235.1.220.0"}]},"Files":[{"Checksum":[{"Filename":"BCM235.1.220.0_BCM957504-P425H.fwpkg","SHA1Sum":"8f3b989e309725cca5fc1a063b602d1d10a6088d","SHA256Sum":"5e0ce71859a0d49bdc79331a4dafa21f8f2c25cf462d7d860c3e0a14535f016d","SHA512Sum":"6c64fc78c0a8d82a2c76eabec00ed76794a5fa1ab27985e17c0f30b5e73aec162c7a6fde4634182072c9fd689dacb5ad186f7a7557ae2b65fac5784f6c736395"}],"ComponentSizeInKB":2738,"CompsigList":[],"FileList":["BCM235.1.220.0_BCM957504-P425H.HPb","BCM235.1.220.0_BCM957504-P425H.xml","payload.json"],"Name":"BCM235.1.220.0_BCM957504-P425H.fwpkg","SHA1Sum":"8f3b989e309725cca5fc1a063b602d1d10a6088d","SHA256Sum":"5e0ce71859a0d49bdc79331a4dafa21f8f2c25cf462d7d860c3e0a14535f016d","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-175114e41599","a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180414e41599"],"TypeOfChange":"1","Version":"235.1.220.0"}],"InstallationDependency":{},"Name":"Broadcom Firmware Package for BCM57504 SFP28 adapters","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_57504_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_fcd534098a6c4cc3beba2806a7","SupportedDevices":["a6b1a447-382a-5a4f-14e4-180114e41599","a6b1a447-382a-5a4f-14e4-180414e41599","a6b1a447-382a-5a4f-14e4-175114e41599"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-159280860002","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.fwpkg","SHA1Sum":"b4692fa59852868b966be1f76a565d1e75d9d137","SHA256Sum":"221449becbc98c0f50e46c46e01eaf80b091db8aab446310b581c410a58859bd","SHA512Sum":"0aaa97d5452c7c06477953aa687b2df938b3243c1603c41091c09ba8b7a9221a856f52d34ba13cfa66621a54baa4bb5170452c773def9089057ea478719cc9ff"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.HPb","HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.xml","payload.json"],"Name":"HPE_E810_CQDA2_4p20_PLDMoMCTP_80017785.fwpkg","SHA1Sum":"b4692fa59852868b966be1f76a565d1e75d9d137","SHA256Sum":"221449becbc98c0f50e46c46e01eaf80b091db8aab446310b581c410a58859bd","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-159280860002"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_f03491120a8a4309a21bea9e57","SupportedDevices":["a6b1a447-382a-5a4f-8086-159280860002"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Lights-Out Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"2f317b9d-c9e3-4d76-bff6-b9d0d085a952","Devices":{"Device":[{"DeviceName":"iLO 5","FirmwareImages":[{"DelayAfterInstallSec":120,"DirectFlashOK":true,"FileName":"ilo5_148.bin","InstallDurationSec":150,"Order":1,"PLDMImage":false,"ResetRequired":false,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":false}],"Target":"4764a662-b342-4fc7-9ce9-258c5d99e815","Version":"1.48"}]},"Files":[{"Checksum":[{"Filename":"firmware-ilo5-1.48-3.1.x86_64.rpm","SHA1Sum":"bc216f1155617115f1e55e1dc6c4b33166dd9b33","SHA256Sum":"10441a45116e8b919188508abe8a3b763c76d189680cf0490bcdf0b855151a17","SHA512Sum":"a8176ccbb28b4b45c781a1cb568e772ffb35e71b4a1fbe3b728afe8d311ea478a52ec21f6b83fbb300d835925ed794c6ab77234090050de41e700b6386c970bd"}],"ComponentSizeInKB":17058,"CompsigList":["firmware-ilo5-1.48-3.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/CP064211.xml","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/LICENSE.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/ilo5_148.bin","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/readme.txt","./usr/lib/x86_64-linux-gnu/firmware-ilo5-1.48-3.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP064211.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP064211.scexe"],"Name":"firmware-ilo5-1.48-3.1.x86_64.rpm","SHA1Sum":"bc216f1155617115f1e55e1dc6c4b33166dd9b33","SHA256Sum":"10441a45116e8b919188508abe8a3b763c76d189680cf0490bcdf0b855151a17","SoftwarePlatforms":[],"TargetGUIDs":["4764a662-b342-4fc7-9ce9-258c5d99e815"],"TypeOfChange":"1","Version":"1.48"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP ProLiant iLO 5 Channel Interface Driver for Windows must be installed prior to this component","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1417651e","SWKey":"necheschif.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE ProLiant Lights-Out Driver must be installed prior to this component ","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9eca0b72f1f","SWKey":"hp_ilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HP Lights-Out Drivers and Agents for Linux","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HP Lights-Out Drivers and Agents for Linux","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec6d7bdce8","SWKey":"hpilo","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]}]}]},"Name":"Online ROM Flash Component for Linux - HPE Integrated Lights-Out 5","PackageFormat":"Linux","PerDeviceInstallTimeSeconds":150,"RebootRequired":"no","SWKeys":[{"Name":"RI11","SWKeyExpectedPath":"firmware:ilo5"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_705315077b1e4ba986471688e7","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["6.0","6.0","6.0","6.0","7.0","11.0","11.0","12.0","15.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I41","U34","U34","A40","U30","U32","A41","U36","U43","U41","HPE ProLiant ML150 Gen10 Server","U33","U44","U40","U39","U45","U37","U38","U38","O43","U38","U38","U38","U40","U39","I43","I42","U31","U31","U40","A42","U46","U46","A43","A45","U51","U47","A46","U47","U47","U47","U50","I44"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR416i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e215900293","Version":"52.26.3.5487"}]},"Files":[{"Checksum":[{"Filename":"CP070862.zip","SHA1Sum":"e10965c4edb70843908488fd733cdd24fd11a332","SHA256Sum":"8a10bac4680cb27eb1a6dc9888fd5dd1d7df2ede7bc496622e1b92d39ebf097e","SHA512Sum":"de22e2eeb59e7aac83fcd5351fc2f1b30dcb0f240a487d6a24e5091f242268c2c0e9cea54bde90d172cdef1a04533ce8f1aa262800982f869b8eae57f8f7976d"}],"ComponentSizeInKB":12765,"CompsigList":["CP070862.compsig"],"FileList":["/CP070862_BUILD_6.data","/CP070862.vmexe64","/CP070862.vmfile","/CP070862_VMw.zip","/CP070862.xml","/payload.json","/CP070862_VMw.zip/index.xml","/CP070862_VMw.zip/vendor-index.xml","/CP070862_VMw.zip/metadata.zip","/CP070862_VMw.zip/vib20/CP070862/HPE_bootbank_CP070862_52.26.3.5487.6-8.0.0.20613240.vib","/CP070862_VMw.zip/metadata.zip/vendor-index.xml","/CP070862_VMw.zip/metadata.zip/vmware.xml","/CP070862_VMw.zip/metadata.zip/vibs/CP070862-1494320092552196309.xml","/CP070862_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070862_52.26.3.5487.6-8.0.0.20613240.xml"],"Name":"CP070862.zip","SHA1Sum":"e10965c4edb70843908488fd733cdd24fd11a332","SHA256Sum":"8a10bac4680cb27eb1a6dc9888fd5dd1d7df2ede7bc496622e1b92d39ebf097e","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e215900293"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP070862","Version":"52.26.3.5487.6-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-p Gen10 Plus Tri Mode Controller","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"02931590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_4706752d8ba24ef0852ae16695","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e215900293"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","U30","U32","A42","A43","A43","U61","U60","SPP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-2CQDA2 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15928086000e","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.fwpkg","SHA1Sum":"ba012c49e28671973d14f4281e4a13fde04ec409","SHA256Sum":"378c3a939e17060e5d877ff5e9a90999d08ea1fc45be853efac52c44500b7958","SHA512Sum":"81e27ca1e9dc24cc355fd6d5976574911a7874e7dc0bc9d8e1128e2824a009de6f7fb2cd6cee3a646aa08b2dce7e0e5003e33358e0d600a50d21e97c648cd522"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.HPb","HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.xml","payload.json"],"Name":"HPE_E810_2CQDA2_O_SEC_4p20_PLDMoMCTP_80017784.fwpkg","SHA1Sum":"ba012c49e28671973d14f4281e4a13fde04ec409","SHA256Sum":"378c3a939e17060e5d877ff5e9a90999d08ea1fc45be853efac52c44500b7958","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15928086000e"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_2CQ2_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_6b034d64eeaf4e40847dab79d8","SupportedDevices":["a6b1a447-382a-5a4f-8086-15928086000e"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM235.1.220.0_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-175114e41598","Version":"235.1.220.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM235.1.220.0_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180114e41598","Version":"235.1.220.0"},{"DeviceName":"Broadcom NetXtreme-E BCM57504 SFP28 OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":false,"FileName":"BCM235.1.220.0_BCM957504-N425H.HPb","InstallDurationSec":360,"Order":1,"PLDMImage":false,"ResetRequired":true,"ServerPowerOff":false,"SysPowerOn":false,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-14e4-180414e41598","Version":"235.1.220.0"}]},"Files":[{"Checksum":[{"Filename":"BCM235.1.220.0_BCM957504-N425H.fwpkg","SHA1Sum":"8a4d1613adb784595127713f2783d3d938fdc0cb","SHA256Sum":"617a2f39e55a482d1f9046a1f1d47171aad22a6264606d69fc09bf5218903daa","SHA512Sum":"1d1ebd90a60da431f68f57ee699b0a74ed82048c88ff2ab047d48f2924848e898532e6dab03a11eab657b56f5b31ff4a479fef76184c74afa5f637571fafbfdf"}],"ComponentSizeInKB":2738,"CompsigList":[],"FileList":["BCM235.1.220.0_BCM957504-N425H.HPb","BCM235.1.220.0_BCM957504-N425H.xml","payload.json"],"Name":"BCM235.1.220.0_BCM957504-N425H.fwpkg","SHA1Sum":"8a4d1613adb784595127713f2783d3d938fdc0cb","SHA256Sum":"617a2f39e55a482d1f9046a1f1d47171aad22a6264606d69fc09bf5218903daa","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-14e4-175114e41598","a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41598"],"TypeOfChange":"1","Version":"235.1.220.0"}],"InstallationDependency":{},"Name":"Broadcom Firmware Package for BCM57504 SFP28 OCP3 adapters","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE_57504OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_17e208fdbfbe47ab9aa8ebec2e","SupportedDevices":["a6b1a447-382a-5a4f-14e4-180114e41598","a6b1a447-382a-5a4f-14e4-180414e41598","a6b1a447-382a-5a4f-14e4-175114e41598"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.20317.25398","10.0.25399"]},{"OS":"Linux","Version":["10.0","8.0","9.0","12.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0","9.0"]}],"SupportedPlatforms":false,"SupportedProducts":["U43","A42","U46","A42","U46","A43","A43","A43","U50","U47","A46","U47","U48","U47","U50","HPE Apollo 2000 Gen10 Plus System","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","H10","H10","U63","U62","U63","A55","A55","A56","A56","U59","U58","U46","U65","U65","U65","H11","U68","U68","U68","U71","U69","A58","U69","U66","U71","U72","U68","A59","U72","U70","A66","A66","U77"],"Type":"ComboFirmware","UpdatableBy":["Uefi"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D715900211","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D71590020E","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D815900212","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D81590020C","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C3","Version":"226.1.107000"},{"DeviceName":"HPE Ethernet 10Gb 2-port 537SFP+ FLR Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16D7159002C5","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EE1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC1590020E","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535FLR-T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535FLR-T-2x10C-14E4-16D8-1590-0212.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF15900212","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 535T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//535T-2x10-14E4-16D8-1590-020C.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EF1590020C","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631FLR-SFP28-2x25-14E4-16D7-1590-0211.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED15900211","Version":"226.1.107000"},{"DeviceName":"HPE NPAR RoCE 631SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//631SFP28-2x25-14E4-16D7-1590-020E.PKG","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED1590020E","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16EC159002C5","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFP-2x10-14E4-16D7-1590-02C3.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C3","Version":"226.1.107000"},{"DeviceName":"NPAR RoCE 537SFP+ FLR","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//537SFPFLR-2x10-14E4-16D7-1590-02C5.pkg","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-14E4-16ED159002C5","Version":"226.1.107000"}]},"Files":[{"Checksum":[{"Filename":"CP070640.zip","SHA1Sum":"8fa176fceee4d489ee16e5f4fcdccccaa7a92097","SHA256Sum":"e7ca1e0217d174df2148da8642cb62015fac674f0b023bb39f08bc47af411057","SHA512Sum":"2fa712613181e3909872e08922774227671df04c8c3a12482d62af8ca5b1cfc744a0f3faf3eeabb6161406293cc70159d456b5f93daf6983a71ebfa8a70c3016"}],"ComponentSizeInKB":15290,"CompsigList":["CP070640.compsig"],"FileList":["/CP070640_BUILD_3.data","/CP070640.vmexe64","/CP070640.vmfile","/CP070640_VMw.zip","/CP070640.xml","/payload.json","/CP070640_VMw.zip/index.xml","/CP070640_VMw.zip/vendor-index.xml","/CP070640_VMw.zip/metadata.zip","/CP070640_VMw.zip/vib20/CP070640/HPE_bootbank_CP070640_226.1.107000.3-8.0.0.20613240.vib","/CP070640_VMw.zip/metadata.zip/vendor-index.xml","/CP070640_VMw.zip/metadata.zip/vmware.xml","/CP070640_VMw.zip/metadata.zip/vibs/CP070640--4426234129328520795.xml","/CP070640_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070640_226.1.107000.3-8.0.0.20613240.xml"],"Name":"CP070640.zip","SHA1Sum":"8fa176fceee4d489ee16e5f4fcdccccaa7a92097","SHA256Sum":"e7ca1e0217d174df2148da8642cb62015fac674f0b023bb39f08bc47af411057","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-14E4-16D715900211","a6b1a447-382a-5a4f-14E4-16D71590020E","a6b1a447-382a-5a4f-14E4-16D815900212","a6b1a447-382a-5a4f-14E4-16D81590020C","a6b1a447-382a-5a4f-14E4-16D7159002C3","a6b1a447-382a-5a4f-14E4-16D7159002C5","a6b1a447-382a-5a4f-14E4-16EE15900212","a6b1a447-382a-5a4f-14E4-16EE1590020C","a6b1a447-382a-5a4f-14E4-16EC15900211","a6b1a447-382a-5a4f-14E4-16EC1590020E","a6b1a447-382a-5a4f-14E4-16EF15900212","a6b1a447-382a-5a4f-14E4-16EF1590020C","a6b1a447-382a-5a4f-14E4-16ED15900211","a6b1a447-382a-5a4f-14E4-16ED1590020E","a6b1a447-382a-5a4f-14E4-16EC159002C3","a6b1a447-382a-5a4f-14E4-16EC159002C5","a6b1a447-382a-5a4f-14E4-16ED159002C3","a6b1a447-382a-5a4f-14E4-16ED159002C5"],"TypeOfChange":"1","Version":"226.1.107000","VibList":[{"Name":"CP070640","Version":"226.1.107000.3-8.0.0.20613240"}]}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for Red Hat Enterprise Linux is required and should be already active prior to this component ","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4374f4af","SWKey":"kmod-bnxt_en","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E driver for SUSE Linux Enterprise Server is required and should be already active prior to this component ","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ece34fd967","SWKey":"bnxt_en-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"","SWKey":"Broadcom-bnxt-Net-RoCE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec55e4f476","SWKey":"bnxtroce","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"AlreadyActive","Description":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Broadcom NetXtreme-E Drivers for VMware vSphere is required and should be already active for this firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec158e843a","SWKey":"bnxtnet","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d715900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d71590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d815900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d81590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16d7159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ee1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef15900212","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ef1590020c","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed15900211","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed1590020e","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ec159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c3","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"},{"Condition":"AlreadyActive","Description":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","DeviceGUID":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Message":"HPE Broadcom Firmware version 226.1.107000 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"a6b1a447-382a-5a4f-14e4-16ed159002c5","SWKey":"BCM_NXE","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"226.1.107000"}]}]}]},"Name":"HPE Broadcom NetXtreme-E Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"BCM_NXE","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_3267d053777342b39e46243b6e","SupportedDevices":["a6b1a447-382a-5a4f-14e4-16d715900211","a6b1a447-382a-5a4f-14e4-16d71590020e","a6b1a447-382a-5a4f-14e4-16d815900212","a6b1a447-382a-5a4f-14e4-16d81590020c","a6b1a447-382a-5a4f-14e4-16d7159002c3","a6b1a447-382a-5a4f-14e4-16d7159002c5","a6b1a447-382a-5a4f-14e4-16ee15900212","a6b1a447-382a-5a4f-14e4-16ee1590020c","a6b1a447-382a-5a4f-14e4-16ec15900211","a6b1a447-382a-5a4f-14e4-16ec1590020e","a6b1a447-382a-5a4f-14e4-16ef15900212","a6b1a447-382a-5a4f-14e4-16ef1590020c","a6b1a447-382a-5a4f-14e4-16ed15900211","a6b1a447-382a-5a4f-14e4-16ed1590020e","a6b1a447-382a-5a4f-14e4-16ec159002c3","a6b1a447-382a-5a4f-14e4-16ec159002c5","a6b1a447-382a-5a4f-14e4-16ed159002c3","a6b1a447-382a-5a4f-14e4-16ed159002c5"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","U39","U64","A40","A41","O43"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"}]},"Files":[{"Checksum":[{"Filename":"firmware-smartarray-98373e8f27_5.61-2.1_amd64.deb","SHA1Sum":"fcfec0e7b9d79128ff8801acf6635af144757f10","SHA256Sum":"01ca58b6515c7ba1e4441fda0b621d0626a73fff371407f362bb8f73c98a18de","SHA512Sum":"4f433a6ab0b5c2d1cbba51805f26a95e836d470af1bb2c9940262507b9f5bdb1ee2c254efaacb4a404585be5dad670042e300e201537efe6aa2dcb939913f3bc"}],"ComponentSizeInKB":7128,"CompsigList":["firmware-smartarray-98373e8f27_5.61-2.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/CP071922.xml","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/HPE_luxor_5.61.bin.fw","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/libsetup.so","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP071922.scexe","./usr/lib/x86_64-linux-gnu/firmware-smartarray-98373e8f27-5.61-2.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP071922.scexe"],"Name":"firmware-smartarray-98373e8f27_5.61-2.1_amd64.deb","SHA1Sum":"fcfec0e7b9d79128ff8801acf6635af144757f10","SHA256Sum":"01ca58b6515c7ba1e4441fda0b621d0626a73fff371407f362bb8f73c98a18de","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"TypeOfChange":"1","Version":"5.61"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Ubuntu - HPE Smart Array P408i-p, P408e-p, P408i-a, E208i-p, E208e-p, E208i-a, P816i-a SR Gen10  controllers","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_87846028abe441eea8ec94c423","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["24.04","22.04","26.04"]}],"SupportedPlatforms":true,"SupportedProducts":["U34","U34","A42","U46","U30","U46","U32","A43","U31","U31","U36","U41","U33","A47","A48","U40","U39","U47","U45","U37","A46","U47","U38","U38","U48","O43","HPE Apollo 6500 Gen10 Plus (Chassis)","U40","U50","U39","I43","I45","I44","I42","U54","U54","U54","U61","U60","U58","U58","U63","U62","U63","U57","A55","A55","A56","A56","U59","U58","U65","U65","U65"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Application - System Management","ComponentLocation":"","CompsigCount":1,"DeviceClass":"e7a8b7dd-a6c0-4056-b14a-97bc423ddc7b","Devices":{"Device":[]},"Files":[{"Checksum":[{"Filename":"sut-5.3.0-10.linux.x86_64.rpm","SHA1Sum":"a2b72c34666e502c4a3379b4a97704a8e34013dc","SHA256Sum":"2a57a95284f853d4a4338e62d4e1941b0deed177cbc351d212f95d5fc8904afc","SHA512Sum":"2806683f99737f7293ac775fea15b30e54d281b7bf4fdfd4bb4ae5ca33bdd08e10919418a1e3d4ff66be1ca4bbc7ec8ca1d79d7bcc2a32c35de3f242231a70ab"}],"ComponentSizeInKB":7635,"CompsigList":["sut-5.3.0-10.linux.x86_64.compsig"],"FileList":["./opt/hp/hpsut/README.txt","./opt/sut/README.txt","./opt/sut/bin/gatherlogs.sh","./opt/sut/bin/hpsut","./opt/sut/bin/sut","./opt/sut/bin/x64/sum_drop_table_x64","./opt/sut/config/sut_cfg_default.dat","./opt/sut/doc/OnDemandHelp.txt","./opt/sut/schemas/SUT.json","./opt/sut/schemas/SUTProvider.json","./opt/sut/schemas/SUTProvider_Gen10.json","./opt/sut/schemas/SUTRegistryEN_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryEN_Redfish.json","./opt/sut/schemas/SUTRegistryEN_Redfish_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Legacy_zipped.json.gz","./opt/sut/schemas/SUTRegistryJP_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings.json","./opt/sut/schemas/SUTSettingsSchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSettingsSchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTSettings_Gen10.json","./opt/sut/schemas/SUTSystemInventorySchema_Legacy_zipped.json.gz","./opt/sut/schemas/SUTSystemInventorySchema_Redfish_zipped.json.gz","./opt/sut/schemas/SUTTasksettings.json","./opt/sut/schemas/SUTTasksettings_Legacy_zipped.json.gz","./opt/sut/schemas/SUTTasksettings_Redfish_zipped.json.gz","./opt/sut/schemas/SUT_Gen10.json","./opt/sut/scripts/sut.service","./opt/sut/scripts/sutd","./usr/lib/.build-id","./usr/lib/.build-id/57","./usr/lib/.build-id/57/374c6b2b55c3ea60f4ebaa7dfd1667b9b459f6","./usr/lib/.build-id/7c","./usr/lib/.build-id/7c/d01fe263104c65c66707eca3d31d173f66dc7e","./usr/share/man/man8/sut.8.gz","./usr/share/smartupdate/sut/component.xml"],"Name":"sut-5.3.0-10.linux.x86_64.rpm","SHA1Sum":"a2b72c34666e502c4a3379b4a97704a8e34013dc","SHA256Sum":"2a57a95284f853d4a4338e62d4e1941b0deed177cbc351d212f95d5fc8904afc","SoftwarePlatforms":[],"TargetGUIDs":["20a6e8e4-bf33-4c71-a6bf-d9ece09b5689"],"TypeOfChange":"1","Version":"5.3.0.0"}],"InstallationDependency":{},"Name":"Integrated Smart Update Tools for Linux x64","PackageFormat":"","PerDeviceInstallTimeSeconds":0,"RebootRequired":"no","SWKeys":[{"Name":"sut","SWKeyExpectedPath":"software:rpm"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_151e85c53b0b4ca0b072e7b487","SupportedDevices":["a6b1a447-382a-5a4f-103c-3307159000e4","a6b1a447-382a-5a4f-103C-330700000000","a6b1a447-382a-5a4f-103c-3306159000e4","a6b1a447-382a-5a4f-103C-330600000000"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["12.0","15.0","8.0","9.0","7.0"]}],"SupportedPlatforms":false,"SupportedProducts":["HP Smart Update Tools (HP SUT)","A55","A55","A56","A56","U34","U34","A42","A40","U46","U30","A42","U46","U32","A43","A43","A43","A41","U31","U31","U43","U41","U33","U44","A47","A48","U40","U47","U45","U37","A46","U47","U38","U38","U48","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","U39","SPP","A42","U56","U61","U60","U64","U46","I43","I44","I42","I45","U65","U65","U58","U59","U63","U62","U63","U54","U58","U58","U69","U71","U69"],"Type":"Software","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Files":[{"Checksum":[{"Filename":"firmware-9041739931-1.2.14.1018-4.1.x86_64.rpm","SHA1Sum":"bf17326d34d078afc7a9909f754188fa715e4a7b","SHA256Sum":"87613aec9bada5568a3ece569e924f75ffd71a585f3e1223ba328f2b1b86ef62","SHA512Sum":"21d4561efb795794991586efeaeb6bb495f03ac0668721ca19383b703809ac7e094fc0826b87eb2b273a4f7b867e195ab83d27a1bd8ada82ed8a46e5835722ef"}],"ComponentSizeInKB":1449,"CompsigList":["firmware-9041739931-1.2.14.1018-4.1.x86_64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/CP068829.xml","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/HPE_NS204i_1.2.14.1018.bin","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/hpsetup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-4.1/setup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP068829.scexe","./usr/lib/x86_64-linux-gnu/scexe-compat","./usr/lib/x86_64-linux-gnu/scexe-compat/CP068829.scexe"],"Name":"firmware-9041739931-1.2.14.1018-4.1.x86_64.rpm","SHA1Sum":"bf17326d34d078afc7a9909f754188fa715e4a7b","SHA256Sum":"87613aec9bada5568a3ece569e924f75ffd71a585f3e1223ba328f2b1b86ef62","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"InstallationDependency":{},"Name":"Online Firmware Flash for Linux(x64) - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_802cc53b3799481086fb450dc3","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-22411590030e"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["15.0","9.0","10.0","16.0"]}],"SupportedPlatforms":false,"SupportedProducts":["I44","U46","A42","U34","U34","A42","U46","U30","U32","A43","A43","A43","U43","U41","U33","U44","A47","A48","U47","A46","U47","U48","U40","U50","U39","A42","U63","U59","I45","U58","U54","U54","U54","U63","A55","A56","A56","A55","U58","U58","H10","H10","H10","I46","U69","U69","U70","U70"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":0,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"Intel E810-XXVDA4 OCP3 adapter","FirmwareImages":[{"DelayAfterInstallSec":0,"DirectFlashOK":true,"FileName":"HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.HPb","InstallDurationSec":120,"Order":1,"PLDMImage":true,"ResetRequired":true,"SysPowerOn":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-8086-15938086000c","Version":"4.20"}]},"Files":[{"Checksum":[{"Filename":"HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.fwpkg","SHA1Sum":"035edc90e72969b4a023d4620531de0006bad125","SHA256Sum":"25858cd4cb92a97b30435fa1f770ffe9c418a132f16bc1c09be8bc8077e23c40","SHA512Sum":"9a18bde884015785a54eaf976ae264c7c63a70b8dae520e23661c1bf4eb7d7037d867a00110374a2daf8a370eeb40f3f1c1d3ebe87e67df587361e4f89fefaf2"}],"ComponentSizeInKB":10274,"CompsigList":[],"FileList":["HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.HPb","HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.xml","payload.json"],"Name":"HPE_E810_XXV4_OCP_4p20_NCSIwPLDMoMCTP_80017788.fwpkg","SHA1Sum":"035edc90e72969b4a023d4620531de0006bad125","SHA256Sum":"25858cd4cb92a97b30435fa1f770ffe9c418a132f16bc1c09be8bc8077e23c40","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-8086-15938086000c"],"TypeOfChange":"1","Version":"4.20"}],"InstallationDependency":{},"Name":"Intel Firmware Package For E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter","PackageFormat":"FWPKG-v2","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"INTEL_E810_XXV4OCP_PKG","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_9bf17c21318f468fad349e91c4","SupportedDevices":["a6b1a447-382a-5a4f-8086-15938086000c"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0.20317.25398"]},{"OS":"Linux","Version":["8.0","9.0","15.0"]},{"OS":"VMware","Version":["7.0","8.0"]}],"SupportedPlatforms":false,"SupportedProducts":["A42","U46","U46","A43","A43","A47","A48","U47","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","H08","HPE Edgeline EL8000t Converged Edge System","H08","HPE Edgeline EL8000 Converged Edge System","H09","A42","U54","U54","U56","H10","U54","U61","U60","U58","U58","U63","U62","U63","A55","A55","A56","A56","U59","U58","U65","U57","U65","H10","H10"],"Type":"Firmware","UpdatableBy":["Bmc"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port 621SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021D","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port 622FLR-SFP28 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021F","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 521T Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-807015900220","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port 524SFP+ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-8070159002BD","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1200R-T Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021A","Version":"8.55.12"},{"DeviceName":"HPE StoreFabric CN1300R Converged Network Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//FW//ql_hp_ah_mbi_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-1077-80701590021B","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"cp069753.exe","SHA1Sum":"f4de67e356ae382d872f093571a758232e720cbf","SHA256Sum":"f1821ebb7e0d4ff2d557fdbd5fd739752d49109a61b05d939969014370d23154","SHA512Sum":"306b7ad25777fbc2637daed18163be276d233eeee083d1ae041db2819e53f5a32eb77e87bd789019a1f37a4eb4a2f758a965fa4d94e7a8d0f9bdf583d3b679f4"}],"ComponentSizeInKB":3039,"CompsigList":["cp069753.compsig"],"FileList":["cp069753.xml","cpqsetup.exe","FW/","FW/firmware.json","FW/ql_hp_ah_mbi_8.55.12.bin","ja/","ja/NICOFUT.chm","LibQLGC_HpFwUpg.dll","NICOFUT.chm","OnlineFWUpgrade.dll","payload.json","QLBBFWUpg.exe","QLMAPIa.dll","tcl83.dll","zh-CN/","zh-CN/NICOFUT.chm"],"Name":"cp069753.exe","SHA1Sum":"f4de67e356ae382d872f093571a758232e720cbf","SHA256Sum":"f1821ebb7e0d4ff2d557fdbd5fd739752d49109a61b05d939969014370d23154","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-80701590021D","a6b1a447-382a-5a4f-1077-80701590021F","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002BD","a6b1a447-382a-5a4f-1077-80701590021A","a6b1a447-382a-5a4f-1077-80701590021B"],"TypeOfChange":"1","Version":"8.55.12"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"AND","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE QLogic FastLinQ 10/25/50 GbE Driver 8.37.37.0 or greater is required for Windows","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec4b661f45","SWKey":"qevbda.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"8.37.37.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910406","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910306","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910206","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910106","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen11 server iLO version 1.10 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen11 server iLO version 1.10 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"E6D3C844-14A6-4F1F-84A3-C06013910006","SWKey":"ILO6","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen12/iLO7 server iLO version 1.10.00 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"","SWKey":"ILO7","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"*"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C0BCF2B9-1141-49AF-AAB8-C73791F0349C","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"C5B14ABD-6D2F-41D7-B665-0447DFDAC3A7","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen10 server iLO version 1.37 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen10 server iLO version 1.37 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"9C057A7A-0D48-4260-B033-558F22EF7C6A","SWKey":"ILO5","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.37"},{"Condition":"InstalledBefore","Description":"For Gen9 server iLO version 2.62 or greater is required and should be already active","DeviceGUID":"2F317B9D-C9E3-4D76-BFF6-B9D0D085A952","Message":"For Gen9 server iLO version 2.62 or greater is required and should be already active","OSVersion":{},"RequirementGUID":"AEEC3229-69CC-43D8-BD0E-61DC3406F71B","SWKey":"ILO4","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"2.62"}]}]}]},"Name":"HPE QLogic FastLinQ Online Firmware Upgrade Utility for Windows Server x64 Editions","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"QLBBFWUpg.exe","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_cc98c2801e0d41d9863df18abc","SupportedDevices":["a6b1a447-382a-5a4f-1077-80701590021d","a6b1a447-382a-5a4f-1077-80701590021f","a6b1a447-382a-5a4f-1077-807015900220","a6b1a447-382a-5a4f-1077-8070159002bd","a6b1a447-382a-5a4f-1077-80701590021a","a6b1a447-382a-5a4f-1077-80701590021b"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0.17600.18999","10.0","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","U30","U30","U32","U31","U31","U36","U43","U41","U33","U44","U40","U39","U45","U37","U38","U38","U26","A40","P89","P89","A41","O43","U40","U39","02020001","03020101","03020102"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Network","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770074","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10/25Gb 2-port SFP28 QL41232HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770073","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HLRJ Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770070","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port BaseT QL41132HQRJ OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770069","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770068","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 2-port SFP+ QL41132HQCU OCP3 Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770071","Version":"8.55.12"},{"DeviceName":"HPE Ethernet 10Gb 4-port SFP+ QL41134HLCU Adapter","FirmwareImages":[{"DelayAfterInstallSec":1,"FileName":".//nic_fw//ql_ah_mbi_open_8.55.12.bin","InstallDurationSec":360,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1077-807010770072","Version":"8.55.12"}]},"Files":[{"Checksum":[{"Filename":"CP070643.zip","SHA1Sum":"e001a275c52c3c8f9a5e5087fb58f24b1d57936f","SHA256Sum":"cadda3d28c4dc4764b28760b4e447bb7c56e88f74e9b1df30dc7e774d1797ec5","SHA512Sum":"eecc42648156a0c388bbbe78b6e3d744da291b87caff967f9e6eb505533bc579f98497d6620be5ad323b21e02159015cfa90e1881806fcccda5fd167740de73d"}],"ComponentSizeInKB":27572,"CompsigList":["CP070643.compsig"],"FileList":["/CP070643_BUILD_9.data","/CP070643.vmexe64","/CP070643.vmfile","/CP070643_VMw.zip","/CP070643.xml","/payload.json","/CP070643_VMw.zip/index.xml","/CP070643_VMw.zip/vendor-index.xml","/CP070643_VMw.zip/metadata.zip","/CP070643_VMw.zip/vib20/CP070643/HPE_bootbank_CP070643_8.55.12.9-8.0.0.20613240.vib","/CP070643_VMw.zip/metadata.zip/vendor-index.xml","/CP070643_VMw.zip/metadata.zip/vmware.xml","/CP070643_VMw.zip/metadata.zip/vibs/CP070643--2511290925962530306.xml","/CP070643_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070643_8.55.12.9-8.0.0.20613240.xml"],"Name":"CP070643.zip","SHA1Sum":"e001a275c52c3c8f9a5e5087fb58f24b1d57936f","SHA256Sum":"cadda3d28c4dc4764b28760b4e447bb7c56e88f74e9b1df30dc7e774d1797ec5","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0"},{"ProductLineID":"embeddedEsx","Version":"9.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"TypeOfChange":"1","Version":"8.55.12","VibList":[{"Name":"CP070643","Version":"8.55.12.9-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Marvell FastLinQ Online Firmware Upgrade Utility for VMware","PackageFormat":"","PerDeviceInstallTimeSeconds":360,"RebootRequired":"yes","SWKeys":[{"Name":"IS_MARVELL_FLQ","SWKeyExpectedPath":"firmware:nic"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_beac71715d1b4ab284ce0cf4b4","SupportedDevices":["a6b1a447-382a-5a4f-1077-807010770074","a6b1a447-382a-5a4f-1077-807010770073","a6b1a447-382a-5a4f-1077-807010770070","a6b1a447-382a-5a4f-1077-807010770069","a6b1a447-382a-5a4f-1077-807010770068","a6b1a447-382a-5a4f-1077-807010770071","a6b1a447-382a-5a4f-1077-807010770072"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["7.0","8.0","9.0","9.1"]}],"SupportedPlatforms":true,"SupportedProducts":["A42","U46","A42","U46","A43","A43","A43","A47","A48","U47","A46","U47","U48","U47","U50","A42","U56","H10","U61","U60","H10","H10","U46","U38","HPE Apollo 2000 Gen10 Plus System"],"Type":"ComboFirmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR216i-p_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032b","Version":"52.26.3.5487"}]},"Files":[{"Checksum":[{"Filename":"CP070860.zip","SHA1Sum":"90270c4ba411aa61668b24e36eacde7a2a2f9327","SHA256Sum":"45f77bb97891e1e7318824ba8295dc9fe173e4a35346821a7e1554a70c595562","SHA512Sum":"0d5c9ab4b9807df9105e8423eadf7ca7142843da1494ec7cb80119ec85d626ead50b706725ee7afc545ecd652272d74f281455286b0181a29efbe1b05f92844c"}],"ComponentSizeInKB":12765,"CompsigList":["CP070860.compsig"],"FileList":["/CP070860_BUILD_3.data","/CP070860.vmexe64","/CP070860.vmfile","/CP070860_VMw.zip","/CP070860.xml","/payload.json","/CP070860_VMw.zip/index.xml","/CP070860_VMw.zip/vendor-index.xml","/CP070860_VMw.zip/metadata.zip","/CP070860_VMw.zip/vib20/CP070860/HPE_bootbank_CP070860_52.26.3.5487.3-8.0.0.20613240.vib","/CP070860_VMw.zip/metadata.zip/vendor-index.xml","/CP070860_VMw.zip/metadata.zip/vmware.xml","/CP070860_VMw.zip/metadata.zip/vibs/CP070860-775760543429782998.xml","/CP070860_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070860_52.26.3.5487.3-8.0.0.20613240.xml"],"Name":"CP070860.zip","SHA1Sum":"90270c4ba411aa61668b24e36eacde7a2a2f9327","SHA256Sum":"45f77bb97891e1e7318824ba8295dc9fe173e4a35346821a7e1554a70c595562","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032b"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP070860","Version":"52.26.3.5487.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR216i-p Gen10 Plus Tri Mode Controller","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"032B1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_ff259d4bb8914bcdaa802549ad","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032b"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","U30","U32","A42","A43","A43","U61","U60","SPP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Files":[{"Checksum":[{"Filename":"firmware-9041739931_1.2.14.1018-1.1_amd64.deb","SHA1Sum":"6f6698485f32f31fb46d6f77a5d55ec32c42ec81","SHA256Sum":"cfdba5e3cdf3d44a140382100141d4ed7b7818665d223897465e7d38357788b4","SHA512Sum":"3266da7a1476053135037b3037a999fbee3e59d281d7c2f6f640ce7a3bc6e0b85081a46fa902138635d07e178cb95b95423f085816fb79febd696a44dbc2eaf8"}],"ComponentSizeInKB":764,"CompsigList":["firmware-9041739931_1.2.14.1018-1.1_amd64.compsig"],"FileList":["./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/.cpq_package.inc","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/.setup","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/CP067804.xml","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/HPE_NS204i_1.2.14.1018.bin","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/mnv_cli","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/payload.json","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/setup","./usr/lib/x86_64-linux-gnu/scexe-compat/CP067804.scexe","./usr/lib/x86_64-linux-gnu/firmware-9041739931-1.2.14.1018-1.1/hpsetup","./usr/lib/x86_64-linux-gnu/hp-scexe-compat/CP067804.scexe"],"Name":"firmware-9041739931_1.2.14.1018-1.1_amd64.deb","SHA1Sum":"6f6698485f32f31fb46d6f77a5d55ec32c42ec81","SHA256Sum":"cfdba5e3cdf3d44a140382100141d4ed7b7818665d223897465e7d38357788b4","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018"}],"InstallationDependency":{},"Name":"Online Firmware Flash for Ubuntu - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_7745ced637364082a3707b93a7","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"SupportedOperatingSystems":[{"OS":"Linux","Version":["22.04","24.04","26.04"]}],"SupportedPlatforms":false,"SupportedProducts":["I44","U46","A42","U34","U34","A42","U46","U30","U32","A43","A43","A43","U43","U41","U33","U44","A47","A48","U47","A46","U47","U48","U40","U50","U39","A42","U63","U59","I45","U58","U54","U54","U54","U63","A55","A56","A56","A55","U58","U58","H10","H10","H10"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE Smart Array P816i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1100","Version":"5.61"},{"DeviceName":"HPE Smart Array P416ie-m SR G10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c1101","Version":"5.61"},{"DeviceName":"HPE Smart Array P408e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0601","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0603","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0602","Version":"5.61"},{"DeviceName":"HPE Smart Array P408i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0600","Version":"5.61"},{"DeviceName":"HPE Smart Array P204i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0700","Version":"5.61"},{"DeviceName":"HPE Smart Array E208e-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0651","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-p SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0650","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-a SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0654","Version":"5.61"},{"DeviceName":"HPE Smart Array E208i-c SR Gen10 Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_luxor_5.61.bin.fw","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":true}],"Target":"a6b1a447-382a-5a4f-9005-028f103c0652","Version":"5.61"}]},"Files":[{"Checksum":[{"Filename":"cp067918.exe","SHA1Sum":"ebbbdc2856035c4c18e359bc04a94ec55c42a209","SHA256Sum":"cb79175d4be1ede24cc6d2d728c6ebba68e6dfd4bb45c2a64095c4ae77ed56f7","SHA512Sum":"163c5c709a116c2b6c928a02c51b15587cb450bdf9031df5461034b5c5c3c803efb5a6678d5c678f7db80c04bd796bb575faf0381c910e1b6c5979b14be9facd"}],"ComponentSizeInKB":7081,"CompsigList":["cp067918.compsig"],"FileList":["cp067918.xml","cpqsetup.exe","HPE_luxor_5.61.bin.fw","payload.json","setup.dll"],"Name":"cp067918.exe","SHA1Sum":"ebbbdc2856035c4c18e359bc04a94ec55c42a209","SHA256Sum":"cb79175d4be1ede24cc6d2d728c6ebba68e6dfd4bb45c2a64095c4ae77ed56f7","SoftwarePlatforms":[],"TargetGUIDs":["a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0650","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652"],"TypeOfChange":"1","Version":"5.61"}],"InstallationDependency":{"DependencyRequirement":[{"ListConditional":"OR","SubRequirements":[{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.1.2-126 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Linux","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.1.2-126"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec024fe8a7","SWKey":"smartpqi-kmp-default","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"sles","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec1a48a0df","SWKey":"smartpqi-kmp-xen","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4-101 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"rhel","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec91247558","SWKey":"kmod-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4-101"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.50.1.0 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"10.0.25399"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ecfaae041b","SWKey":"SmartSAMD.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.50.1.0"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 63.32.0.64 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"Windows","Value":"*"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec040331c1","SWKey":"SmartPqi.sys","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"63.32.0.64"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.0.1060-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.5"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.0.1060-1-1OEM.650.0.0.4598673"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"E7A8B7DD-A6C0-4056-B14A-97BC423DDC7B","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.2.1028-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"6.0"},"RequirementGUID":"20a6e8e4-bf33-4c71-a6bf-d9ec72979cda","SWKey":"smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.2.1028-1OEM.600.0.0.2768847"}]},{"ListConditional":"OR","Requirement":[{"Condition":"AlreadyActive","Description":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","DeviceGUID":"","Message":"HPE Smart Array Gen10 Controller Driver version 1.0.4.3011-1 or greater is required and should be already active for firmware update. Update the driver and reboot before attempting firmware update.","OSVersion":{"Name":"VMWare","Value":"7.0"},"RequirementGUID":"","SWKey":"Microchip-smartpqi","ServerModel":["*"],"TargetGUIDs":[],"Type":"GTE","Version":"1.0.4.3011-1vmw.700.1.0.1552599"}]}]}]},"Name":"Online ROM Flash Component for Windows (x64) - HPE Smart Array P408i-p, P408e-p, P408i-a, P408i-c, P204i-c, E208i-p, E208e-p, E208i-a, E208i-c, P816i-a, P416ie-m SR Gen10","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"1100103C","SWKeyExpectedPath":"firmware"},{"Name":"1101103C","SWKeyExpectedPath":"firmware"},{"Name":"0601103C","SWKeyExpectedPath":"firmware"},{"Name":"0603103C","SWKeyExpectedPath":"firmware"},{"Name":"0602103C","SWKeyExpectedPath":"firmware"},{"Name":"0600103C","SWKeyExpectedPath":"firmware"},{"Name":"0700103C","SWKeyExpectedPath":"firmware"},{"Name":"0651103C","SWKeyExpectedPath":"firmware"},{"Name":"0650103C","SWKeyExpectedPath":"firmware"},{"Name":"0654103C","SWKeyExpectedPath":"firmware"},{"Name":"0652103C","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_c1becc9ec194435c8ad7529bca","SupportedDevices":["a6b1a447-382a-5a4f-9005-028f103c0700","a6b1a447-382a-5a4f-9005-028f103c0601","a6b1a447-382a-5a4f-9005-028f103c0602","a6b1a447-382a-5a4f-9005-028f103c0603","a6b1a447-382a-5a4f-9005-028f103c0600","a6b1a447-382a-5a4f-9005-028f103c1101","a6b1a447-382a-5a4f-9005-028f103c1100","a6b1a447-382a-5a4f-9005-028f103c0651","a6b1a447-382a-5a4f-9005-028f103c0654","a6b1a447-382a-5a4f-9005-028f103c0652","a6b1a447-382a-5a4f-9005-028f103c0650"],"SupportedOperatingSystems":[{"OS":"Windows","Version":["10.0","10.0","10.0","10.0.17600.18999","10.0.20317.25398","10.0.25399"]},{"OS":"Azure","Version":["10.0.25398.25398","10.0.26100.26100"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A40","U30","U32","A41","U31","U31","U36","U41","U33","U40","U39","U45","U37","U38","U38","O43","U40","U39","I43","I42","U48","A43","A42","U46","U46","A47","A48","U47","A46","U47","HPE Apollo 6500 Gen10 Plus (Chassis)","U50","I44","A42","A43","A43","A42","HPE Apollo 2000 Gen10 Plus System","U60","U61","U65","U65","U57","U58","U58","I45","A56","U58","U54","U54","U54","U63","U63","U59","U62"],"Type":"ComboFirmware","UpdatableBy":["Uefi","RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79f0c163-0c13-4662-9dea-09235fef90cb","Devices":{"Device":[{"DeviceName":"HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"MR416i-a_NOPAD.rom","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1000-10e21590032a","Version":"52.26.3.5487"}]},"Files":[{"Checksum":[{"Filename":"CP070861.zip","SHA1Sum":"109edd1792a3a876e0e70cdd8f2be89daad2f91d","SHA256Sum":"da063f438994c18533d2466a36ded1f10ad6bf260668c12a16ea02df7dacd8f3","SHA512Sum":"87dbda50fd5fb600bfe86e5430129bc748e3463ad97d1b3aea5856fe377576ee7e70f0eade47a52df7ad7753e7da3425aa1c0df0f563f1f4553c4203e3e957eb"}],"ComponentSizeInKB":12765,"CompsigList":["CP070861.compsig"],"FileList":["/CP070861_BUILD_3.data","/CP070861.vmexe64","/CP070861.vmfile","/CP070861_VMw.zip","/CP070861.xml","/payload.json","/CP070861_VMw.zip/index.xml","/CP070861_VMw.zip/vendor-index.xml","/CP070861_VMw.zip/metadata.zip","/CP070861_VMw.zip/vib20/CP070861/HPE_bootbank_CP070861_52.26.3.5487.3-8.0.0.20613240.vib","/CP070861_VMw.zip/metadata.zip/vendor-index.xml","/CP070861_VMw.zip/metadata.zip/vmware.xml","/CP070861_VMw.zip/metadata.zip/vibs/CP070861--5824522441084647177.xml","/CP070861_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070861_52.26.3.5487.3-8.0.0.20613240.xml"],"Name":"CP070861.zip","SHA1Sum":"109edd1792a3a876e0e70cdd8f2be89daad2f91d","SHA256Sum":"da063f438994c18533d2466a36ded1f10ad6bf260668c12a16ea02df7dacd8f3","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1000-10e21590032a"],"TypeOfChange":"1","Version":"52.26.3.5487","VibList":[{"Name":"CP070861","Version":"52.26.3.5487.3-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Controller Firmware Flash for ESXi8.0 and 9.0 - HPE MR416i-a Gen10 Plus Tri Mode Controller","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"032A1590","SWKeyExpectedPath":"firmware"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2bfd49954b34412891e51a2b26","SupportedDevices":["a6b1a447-382a-5a4f-1000-10e21590032a"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U46","U46","A42","U30","U32","A42","A43","A43","U61","U60","SPP"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]},{"BundleIndex":0,"Category":"Firmware - Storage Controller","ComponentLocation":"","CompsigCount":1,"DeviceClass":"79F0C163-0C13-4662-9DEA-09235FEF90CB","Devices":{"Device":[{"DeviceName":"HPE NS204i-p Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-2241159002f6","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen10+ Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-22411590030e","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-u Boot Controller Kit","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900379","Version":"1.2.14.1018"},{"DeviceName":"HPE NS204i-d Gen11 Boot Controller","FirmwareImages":[{"DelayAfterInstallSec":10,"DirectFlashOK":false,"FileName":"HPE_NS204i_1.2.14.1018.bin","InstallDurationSec":300,"Order":1,"ResetRequired":true,"Type":"Firmware","UEFIFlashable":false}],"Target":"a6b1a447-382a-5a4f-1b4b-224115900380","Version":"1.2.14.1018"}]},"Files":[{"Checksum":[{"Filename":"CP070870.zip","SHA1Sum":"650f5a095f9854b6955dde4d09ff0cc40febc92b","SHA256Sum":"9fb6f0f9cbcd2ba606a9df3972ef4fedb7792fe44942112b5b69b57ffbeac4b0","SHA512Sum":"33f02bfc6f67f1fd355a77e026a4a6cb13ce2c52f2b5ce7a179824b93ececd33c7378e9aec3b331b458876a9d1f3afb3cdfe8e55d50f948ccc6d512b32749db7"}],"ComponentSizeInKB":2464,"CompsigList":["CP070870.compsig"],"FileList":["/CP070870_BUILD_4.data","/CP070870.vmexe","/CP070870.vmexe64","/CP070870.vmfile","/CP070870_VMw.zip","/CP070870.xml","/payload.json","/CP070870_VMw.zip/index.xml","/CP070870_VMw.zip/vendor-index.xml","/CP070870_VMw.zip/metadata.zip","/CP070870_VMw.zip/vib20/CP070870/HPE_bootbank_CP070870_1.2.14.1018.4-8.0.0.20613240.vib","/CP070870_VMw.zip/metadata.zip/vendor-index.xml","/CP070870_VMw.zip/metadata.zip/vmware.xml","/CP070870_VMw.zip/metadata.zip/vibs/CP070870-6632410356789207801.xml","/CP070870_VMw.zip/metadata.zip/bulletins/Smart-Component-CP070870_1.2.14.1018.4-8.0.0.20613240.xml"],"Name":"CP070870.zip","SHA1Sum":"650f5a095f9854b6955dde4d09ff0cc40febc92b","SHA256Sum":"9fb6f0f9cbcd2ba606a9df3972ef4fedb7792fe44942112b5b69b57ffbeac4b0","SoftwarePlatforms":[{"ProductLineID":"embeddedEsx","Version":"8.0.0"},{"ProductLineID":"embeddedEsx","Version":"9.0.0"}],"TargetGUIDs":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-22411590030e","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380"],"TypeOfChange":"1","Version":"1.2.14.1018","VibList":[{"Name":"CP070870","Version":"1.2.14.1018.4-8.0.0.20613240"}]}],"InstallationDependency":{},"Name":"Online Firmware Flash for ESXi - HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d","PackageFormat":"","PerDeviceInstallTimeSeconds":300,"RebootRequired":"yes","SWKeys":[{"Name":"02F61590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"030E1590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03791590","SWKeyExpectedPath":"firmware:sd:"},{"Name":"03801590","SWKeyExpectedPath":"firmware:sd:"}],"SupportURL":"https://support.hpe.com/hpsc/swd/public/detail?swItemId=MTX_2965a33e83ba4d60875eeeb4cd","SupportedDevices":["a6b1a447-382a-5a4f-1b4b-2241159002f6","a6b1a447-382a-5a4f-1b4b-224115900379","a6b1a447-382a-5a4f-1b4b-224115900380","a6b1a447-382a-5a4f-1b4b-22411590030e"],"SupportedOperatingSystems":[{"OS":"VMware","Version":["8.0","9.0","9.1"]}],"SupportedPlatforms":false,"SupportedProducts":["U34","U34","A42","U30","U32","A43","U41","U33","U47","A46","U47","U50","I44","U46","U46","U39","U40","A47","A48","A42","A43","A43","U43","A42","U44","U48","U63","U59","I45","U58","U54","U54","U54","U63","A55","A56","A56","A55","U58","U58","H10","H10","H10","U46","H11","I46","U69","U69","U70","U70"],"Type":"Firmware","UpdatableBy":["RuntimeAgent"]}],"SupplementBundleLocation":[],"VMwareAddonInfo":[{"ComponentLocation":"","FileName":"HPE-803.0.0.10.26.0.12-Sep2026-Addon-depot.zip","NameSpec":{"Name":"HPE-SPP-2026-09-00-00","UIString":"Service Pack for ProLiant Manifest"},"SHA1Sum":"65856b8689556f5e0ce312db84555dc4353af812","SHA256Sum":"dedde9d85cb3896b471874c67c531568c35a565ab36876280bb1c55ae5e3b39f","SizeInKB":40719,"SupportedBaseImageVersions":["8.0.3"],"VersionSpec":{"UIString":"803.0.0.10.26.0-12","Version":"803.0.0.10.26.0-12"}},{"ComponentLocation":"","FileName":"HPE-900.0.0.10.10.0.12-Sep2026-Addon-depot.zip","NameSpec":{"Name":"HPE-SPP-2026-09-00-00","UIString":"Service Pack for ProLiant Manifest"},"SHA1Sum":"3b9bafbd47f4dcf01c6f65444db9b150333630cf","SHA256Sum":"5369f53ae519e344418ac40fecfe7337ce903310c466c424279a6ef63b57edbd","SizeInKB":38521,"SupportedBaseImageVersions":["9.0"],"VersionSpec":{"UIString":"900.0.0.10.10.0-12","Version":"900.0.0.10.10.0-12"}},{"ComponentLocation":"","FileName":"HPE-910.0.0.10.4.0.13-Sep2026-Addon-depot.zip","NameSpec":{"Name":"HPE-SPP-2026-09-00-00","UIString":"Service Pack for ProLiant Manifest"},"SHA1Sum":"df977112daa72f9dc56372d5cdd377d315ea9157","SHA256Sum":"4b2a5a01d0429adb54d1c04957a12301656a55882ba8f584c7a41885001eb03c","SizeInKB":38351,"SupportedBaseImageVersions":["9.1"],"VersionSpec":{"UIString":"910.0.0.10.4.0-13","Version":"910.0.0.10.4.0-13"}}]}],"SchemaVersion":"2.0"}